Footing Calculation 1.0 Design Parameters

This document provides a footing calculation for a 400mm x 400mm x 400mm concrete footing. It includes the design parameters, design forces, and calculations to check the compressive strength, yield strength, unit weight, wind and structural loading, reactions, and uplift resistance. It also considers fill material properties and calculates the passive pressure resistance to verify it exceeds the maximum calculated loading of 0.97kN. The footing design meets the specified factors of safety.

Uploaded by

Siva Jase
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views1 page

Footing Calculation 1.0 Design Parameters

This document provides a footing calculation for a 400mm x 400mm x 400mm concrete footing. It includes the design parameters, design forces, and calculations to check the compressive strength, yield strength, unit weight, wind and structural loading, reactions, and uplift resistance. It also considers fill material properties and calculates the passive pressure resistance to verify it exceeds the maximum calculated loading of 0.97kN. The footing design meets the specified factors of safety.

Uploaded by

Siva Jase
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Job No: 2015-0075

Sheet No: 1
Designed by: KAM Checked by: KH TANN Date: 5/6/2019
Title:

FOOTING CALCULATION

1.0 Design Parameters

b = 400 mm , width of footing


l = 400 mm , length of footing
d = 400 mm , depth of footing
EN 1992 1-1
Af = 160000 mm2 , Area of footing (3.15)
EN 1992 1-1
2
fck = 20 N/mm , compressive strenght of Concrete
2
fyk = 460 N/mm , yield strength of steel
2
fcd = 0.85 Fck = 11.333 N/mm Table 3.1
1.5
fyd = fyk = 400 N/mm2
1.15
3
gc = 25 kN/m , Unit weight of Concrete
fctm = 2.9

2.0 Design Forces Hoarding Panel


Thickness of Hoarding sheet = 0.625 mm

Unitl Weight hoarding Panel = 78*0.625/1000 kN/m2


= 0.0488

Total Structural Weight = 0.0488*3*2.5 kN


= 0.366 kN

2
0.1 kN/m2 Wind load = 0.25 kN/m
rom Staad Analysis
Reactions R1 = 1.88 kN
X1 = 0.256 kN
R2 = -1.11 kN
1.5 m X2 = 0.97 kN

Weight of the Footing = 24*0.4*0.4*0.4 +0.366


= 1.90 kN
Uplift Resistance of Soil = 0.00 kN

Over Design F.O.S = 1.71 > 1.60

R1 R2 Hene ok

A
1.2 m
Consider Fill material
Friction Angle = 30.0 degree
400X400X400 400X400X400 Cohesion = 3.00 kN/m2

Passive Pressure Coffeciant kp = 1+sin ϴ = 3.00


1-sin ϴ

Passive pressure Resistance = 21.60 kN/m2


Max Passive Loading = 4.32 kN > 0.97 kN

Hence ok