Fab/Mbbr: Temperature Altitude M Standard Oxygen Transfer Efficiency °C

This document provides specifications for an FAB/MBBR wastewater treatment system including flow rate, operating hours, BOD and TKN loads, area and volume of media tanks, required air flow rates, and dissolved oxygen transfer rates at various temperatures and altitudes. Key parameters include a flow rate of 500 m3/day, 150 kg/day total BOD load, 4.5 m side water depth, 350 m2/m3 media surface area, and 404 m3/hr required air flow rate. Dissolved oxygen transfer rates are also specified for temperatures from 0 to 40°C and altitudes from sea level to 100 m.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views19 pages

Fab/Mbbr: Temperature Altitude M Standard Oxygen Transfer Efficiency °C

This document provides specifications for an FAB/MBBR wastewater treatment system including flow rate, operating hours, BOD and TKN loads, area and volume of media tanks, required air flow rates, and dissolved oxygen transfer rates at various temperatures and altitudes. Key parameters include a flow rate of 500 m3/day, 150 kg/day total BOD load, 4.5 m side water depth, 350 m2/m3 media surface area, and 404 m3/hr required air flow rate. Dissolved oxygen transfer rates are also specified for temperatures from 0 to 40°C and altitudes from sea level to 100 m.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 19

FAB/MBBR

Flow Rate m3/day


Operating Hour h
BOD Load mg/L
TKN Load mg/L
Total Applied BOD kg/day
BOD Removal
Surface Loading Rate m2/m3/day
Side Water Depth m
Surface Area of media m2/m3
Volume of media m3
Media Fill Volume
Volume of tank m3
Area of Tank m2
No of tanks
Area of one compartment m2
Diameter of tank m
Provided Diameter m

AIR REQUIRED
Temperature °C
Altitude m

Standard Oxygen Transfer efficiency

Theoritical Oxygen requirment kg/day


Standard Oxygen Requirment kg/h
Air Flow Rate m3/h
Air Blower m3/h
Fine Bubble Diffusers (1000 mm) Nos.
Fine Bubble Diffusers (550 mm) Nos.
B/MBBR
500
24
300
0
150
Morderate BOD Removal (85-90%)
15
4.5
350
28.6
0.25
114.29
25.40
2
12.70
4.02
4.1

REQUIRED
25
100

22.5

270
25.15
404.26
404.26
52
82
Surface Loading rate
Low BOD Removal (75-80%) 25
Morderate BOD Removal (85-90%) 15
High BOD Removal (90-95%) 7.5
AOR α F θ β CS Cs20 CL
270 0.7 0.8 1.024 0.95 8.9 9.1 2

Altitude 100
Pressure 100.1295 kpa

Atmospheric Pressure
Temperature 106 105.3 104.6 104 103.3 102.6 102
0 15.3 15.2 15.1 15 14.9 14.8 14.7
5 13.3 13.3
10
15
20
25
30
35
40
SOR per day SOR per hr Air Flow Rate
603.7 25.15 404.26

101.3 100.65 100 99.32 98.65 98 97.32 96.65 96


14.6 14.5 14.4 14.3 14.2 14.1 14 13.9 13.8
95.32 94.65 94 93.32 92.65 92 91.32 90.5 90 89.32
13.7 13.6 13.5 13.4 13.3 13.2 13.1 13 12.9 12.8
88.65 88 87.32 86.65 86 85.32 84.65 84 83.32 82.65
12.7 12.6 12.5 12.4 12.3 12.2 12.1 12 11.9 11.8
82 81.32 80.66 80
11.7 11.6 11.5 11.4