Panel programming guide
Communicator versions up to 5.41
Johnson Controls —
Connect Alarm
The alarm system (panel and communicator) need to be set up in order to
connect to the server that provides the connection service for the Connect
Alarm smartphone application.
The alarm system (panel and communicator) can connect with the server over
Ethernet (recommended) or Cellular (not both).
Minimum required Neo panel firmware version is 1.3 and communicator
firmware version 5.03 Panel firmware version can be checked via installer
menu [900][000] and communicator firmware version via installer menu
[851][991] (installer menu [851] can be accessed only after menu [382][5] is
enabled).
2 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – data consumption
There are four integrations/sessions that can be used. in this document
integration session 1 is used for the Ethernet configuration and integration
session 2 is used for cellular configuration.
The Ethernet receiver can be defined as receiver 1 or 2 (in our document we
use receiver 1) and Cellular receiver can be defined as receiver 3 or 4 (in our
document we use receiver 3)
It is recommended to perform panel/communicator factory reset before starting
the configuration (communicator: [993]<installer code>[993] and then panel:
[999]<installer code>[999]). Be aware that this erases all previous
configurations.
3 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – HEX and ASCII data
To enter HEX data, perform the following:
Step 1 – Enter a section that allows for HEX data entries
Step 2 – Press [*] to enter HEX programming, the ‘Ready’ LED
will flash to indicate that HEX programming has been entered
Step 3 – Enter the required HEX data where switch from digits
to letters is done with '*‚ button :
1=A
2=B
3=C
4=D
5=E
6=F
Step 4 – Press [*] to exit HEX programming, the ‘Ready’ LED
will return to solid
Alphanumeric keyboard (for entering the APN or the domain
name of the server): to enter '.', change to ASCII (press the
'*' button and switch to ASCII with the <> buttons) and enter
046 and press the '*' button.
4 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – Ethernet connection part 1
Menu Option Value/Name
382 005 Y -- Alternate communicator module enabled
300 001 (chosen 03 – alternate communicator receiver 1.
receiver) change all other unused receivers (002-004) to ‘01-phone line’
In case of using groups set to 02 – Alt Comm Auto (see slide 9 ‘communicator 5.21 – group setting’)
380 1 ‘Y’ “Enable communication”
310 000 System Account Code (needs to be different from FFFF)
310 001-008 Partition 1-8 (needs to be set according to used partitions) Account Code (needs to be different from FFFF)
001 Static panel IP (0.0.0.0 – DHCP enabled) . panel’s current IP can be seen in menu [851][992]
002 Subnet mask (set automatically when DHCP is enabled)
003 Gateway IP address (set automatically when DHCP is enabled)
851
005 Set option ‘3’ (Supervision Type)
007 Static DNS 1 (set automatically when DHCP is enabled) Panel’s DNS IP can be seen in menu [851][988]
5 Johnson Controls —
Connect Alarm – Ethernet connection part 2
Menu Option Value/Name
101 10 hex char -- Account code
set receiver account to be identical to integration identification number ([851][422]) with 2 digits less.
if for example the integration identification number is 1234567890ab, then the account will be 24567890ab.
106 Enter URL of the cloud server: connect.tycomonitor.com (receiver 1 URL name)
104 0BF5 (hex) -- 3061 Remote port
425 Set options ‘3’ (integration Over Ethernet) and ‘4’ (type 2 encryption) and ‘5’ (Integration Protocol)
426 Set option ‘3’ (Real-Time Notification)
851
431 Enter URL of the cloud server: connect.tycomonitor.com (integration 1 URL name)
429 0517 (hex) -- 1303 (dec) Integration Notification Port
006 [below communicator version 5.40] Set option ‘1’ (Ethernet receiver enabled)
100 [communicator version 5.40 and above] set options ‘1’ (Ethernet receiver 1) and ‘2’ (Ethernet receiver 1 supervision)
010 Set option ‘2’ (Video Verification Enabled)
008 Static DNS 2 (set automatically when DHCP is enabled). Panel’s DNS IP can be seen in menu [851][989]
6 Johnson Controls —
Connect Alarm – Cellular connection part 1
Menu Option Value/Name
382 005 Y -- Alternate communicator module enabled
380 1 ‘Y’ “Enable communication”
300 003 05 – alternate communicator receiver 3.
change all other unused receivers (001, 002 and 004) to ‘01-phone line’
In case of using groups set to 02 – Alt Comm Auto (see slide 9 ‘communicator 5.21 – group setting’)
310 000 System Account Code (needs to be different from FFFF)
310 001-008 Partition 1-8 (needs to be set according to used partitions) Account Code (needs to be different from
FFFF)
7 Johnson Controls —
Connect Alarm – Cellular connection part 2
Menu Option Value/Name
005 Set option ‘3’ (Supervision Type)
206 URL of the cloud server: connect.tycomonitor.com (receiver 3 URL name)
204 0BF6 (hex) -- 3062 Remote port
205 Enter name for APN
451 Add SMS label “neo go” – non-capital letters without quotes
851
452 Set options ‘2’ (integration Over Cellular) and ‘4’ (type 2 encryption) and ‘5’ (Integration Protocol)
453 Set option ‘3’ (Real-Time Notification)
458 URL of the cloud server: connect.tycomonitor.com (Integration 2 URL name)
456 0518 (hex) -- 1304 Integration Notification Port
006 [below communicator version 5.40] Set option ‘4’ (Cellular Receiver Enabled)
200 [communicator version 5.40 and above] set options ‘1’ (Cellular receiver 1) and ‘2’ (Cellular receiver 1 supervision)
201 10 hex char -- Account code
set receiver account to be identical to integration identification number ([851][422]) without digit 1 and 3.
If - for example - the integration identification number is 1234567890ab, then the account will be 24567890ab.
8 Johnson Controls —
Connect Alarm – communicator 5.21 – group setting
From communicator version 5.21 and on visual verification can be sent to two receivers in
parallel using the group feature. It is useful in case of connection to two power-manage servers
or when using both SurGard receiver and power-manage server. Do the following:
Set [380] option 5 ‘Parallel Communications’ to ON
Change [300][<two receiver numbers> ‘entry 02’ to ‘Alt Comm Auto’
set [851][010] option 4 to ON (enable groups)
In menu [851][018] enter the two receivers that will receive the video. For example, to
create a group of receivers 1 and 2, enter 0102.
9 Johnson Controls —
Connect Alarm – further steps and remarks
Connection to the cloud server is made via ITv2 and Fibro protocols at the same time to ensure
smooth and quick app reactions. This is different from ‘neo go’ application that required ITv2
connection only.
In case of concurrent Sur-Gard communication, both Sur-Gard and cloud server should be
getting events simultaneously
Once fully programmed, please reboot panel and communicator (disconnect all power supplies
including AC and battery)
Make sure that non-used receivers IP fields are set to 0.0.0.0 (Ethernet Receiver 1 Address:
[851][103], Ethernet Receiver 2 Address: [851][113], Cellular Receiver 1 Address: [851][203],
Cellular Receiver 2 Address: [851][213])
10 Johnson Controls — Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
Connect Alarm – further steps and remarks
Enable receiving Arm/Disarm events
go over menus [311] – [318] (all 8 partitions or according to the partitions in your panel) and in
each enable [001], [002] and [003] to the relevant receivers so the alarm/tamper/open-close
statuses will show up in the mobile app.
Enable siren for Panic Alarm
[015] -> 02 -> Y - [P] Key Audible (Bell/Beeps)
Integration access code
[851][423] - make sure the access code is the default value (normally 12345678). Communicators
version 5.30 and above use encryption type 2 and menu [851][700].
11 Johnson Controls —
Connect Alarm – further steps and remarks
If Integration session 1 in panel is used for different purpose than Connect Alarm application, then
Session 2, 3 or 4 can be used instead.
Session 1 Session 2 Session 3 Session 4
[423] [450] [477] [504] Session X integration access code
[424] [451] [478] [505] Session X SMS label
[425] [452] [479] [506] Session X Integration Toggle Option 2
[426] [453] [480] [507] Session X Integration Toggle Option 3
[428] [455] [482] [509] Session X Integration Server IP
[429] [456] [483] [510] Session X Integration Notification Port
[431] [458] [485] [512] Session X Integration Server DNS
12 Johnson Controls —
Connect Alarm – further steps and remarks
If the receiver 1 is used for different purpose than Connect Alarm application, then Receivers 2, 3 or 4 can
be used.
Receiver 1 Receiver 2 Receiver 3 Receiver 4
(Ethernet-1) (Ethernet-2) (Cellular-1) (Cellular-2)
[300] [001] [300] [002] [300] [003] [300] [004] “panel/receiver communication path” (not used
paths should be configured to [01] “Phone Line”)
[851][101] [851][111] [851][201] [851][211] Ethernet/Cellular receiver X Account Code
[851][106] [851][106] [851][206] [851][216] Ethernet/Cellular receiver X Domain Name
[851][104] [851][114] [851][204] [851][214] Ethernet/Cellular Receiver X UDP Remote port
[851][006][1] [851][006][2] [851][006][4] [851][006][5] Ethernet/Cellular X receiver enabled
[851][205] [851][215] Cellular Receiver X APN
13 Johnson Controls —
Connect Alarm Activation
Before end user uses the app for the first time, installer activation is required
Download the Connect Alarm activation app from Google Play Store or Apple App store
Install app in your phone
Start the app and accept Terms of Use
On the welcome screen, enter server host address (connect.tycomonitor.com) and press Next
On the next screen, choose option Register new account at the bottom
Fill in necessary data and press register
Provide your email and password you just set and press LOGIN
Press „+” button to add panel
Enter panel webname (Integration Identification Number – can be found in option [851][422])
Click the panel and provide Master Installer Code
The panel will be activated and can be used by end user
14 Johnson Controls —
Connect Alarm Activation (cont.)
The user-app activation which is done by the ‘connect alarm activation’ mobile-app can be performed only
when there is an active connection between the power-manage server and the Neo panel. When using a
GPRS/Cellular Neo panel, most of the time the panel is disconnected (the panel is connected when user
is logged in the user-app ‘connect alarm’ and up to 5 minutes after exiting installer menu) from the server
and therefore the panel cannot be activated. To reconnect the panel to the server please send to the
panel the following SMS: connectXXXXXXXXXXXX05205917105501304neo go or exit from installer
code.
The XXXXXXXXXXXX should be replaced with the panel ID which is located in installer menu
[851][422] (also called ‘panel webname’ in the ‘connect alarm activation’ or ‘panel ID’ in the ‘connect
alarm’ application).
Sending the SMS will cause the panel to connect within few seconds to the server so the activation
process can complete
15 Johnson Controls —
Connect Alarm – App installation and first use
Download the app from Google Play Store or Apple App store
Install app in your phone
Start the app and accept Terms of Use
On the welcome screen, enter server address (connect.tycomonitor.com) and press „+” button (Android)
or “Add New” button (iOS)
Add preferred name for the panel and enter panel ID (Integration Identification number). This number can
be found in option [851][422]
Click the panel and enter Master User Code (first use) or User Code
16 Johnson Controls —
Contact information
Technical support:
[email protected]