Contact ID Codes With Explanation

This document contains a list of event codes and their corresponding descriptions related to contact IDs. The event codes range from 100 to 301 and describe different types of medical, fire, panic, burglary, environmental, and system trouble alarms or faults that could be detected on a monitoring system. Each event is assigned a zone and provides a brief description of the condition represented by that event code.

Uploaded by

JEC Col
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9K views8 pages

Contact ID Codes With Explanation

This document contains a list of event codes and their corresponding descriptions related to contact IDs. The event codes range from 100 to 301 and describe different types of medical, fire, panic, burglary, environmental, and system trouble alarms or faults that could be detected on a monitoring system. Each event is assigned a zone and provides a brief description of the condition represented by that event code.

Uploaded by

JEC Col
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Contact ID as of 2/27/2019

Event Assignment CCC Field Description


code info
100 Medical Zone A non-specific medical condition exists
101 Personal Emergency Zone Emergency Assistance request
102 Fail to report in Zone A user has failed to activate a monitoring device
110 Fire Zone A non-specific fire alarm condition exists
111 Smoke Zone An alarm has been triggered by a smoke detector
112 Combustion Zone An alarm has been triggered by a combustion detector
113 Water Flow Zone An alarm has been triggered by a water flow detector
114 Heat Zone An alarm has been triggered by a heat detector
115 Pull Station Zone A pull station has been activated
116 Duct Zone An alarm has been triggered by a duct detector
117 Flame Zone An alarm has been triggered by a flame detector
118 Near Alarm Zone A near-alarm condition has been detected on a fire sensor
120 Panic Zone A non-specific hold-up alarm exists
121 Duress User A duress code has been entered by a user
122 Silent Zone A silent hold-up alarm exists
123 Audible Zone An audible hold-up alarm exists
124 Duress – Access granted Zone A duress code has been entered and granted at an entry door
125 Duress – Egress granted Zone A duress code has been entered and granted at an exit door
126 Hold-up suspicion print User A user has activated a trigger to indicate a suspicious condition
127 Remote Silent Panic User A silent panic alarm has been initiated remotely by a user
129 Panic Verifier Zone A confirmed Hold-up condition exists
130 Burglary Zone A burglary zone has been violated while armed
131 Perimeter Zone A perimeter zone has been violated while armed
132 Interior Zone An interior zone has been violated while armed
133 24 Hour (Safe) Zone A 24 hour burglary zone has been violated
134 Entry/Exit Zone An Entry/Exit zone has been violated while armed
135 Day/Night A Trouble by Day / Alarm by Night zone has been violated while
Zone
armed
136 Outdoor Zone An outdoor burglary zone has been violated while armed
137 Tamper Zone A burglary zone has been tampered with while armed
138 Near alarm A burg sensor has detected a condition which will cause it to go into
Zone
alarm if the condition worsens
139 Intrusion Verifier Zone The specified zone has verified that an intrusion has occurred
140 General Alarm Zone The specified zone is in an alarm condition
141 Polling loop open An open circuit condition has been detected on a polling loop while
Zone
the system was armed
142 Polling loop short A short circuit condition has been detected on a polling loop while the
Zone
system was armed
143 Expansion module failure A general failure condition has been detected on an expansion
Zone
module while the system was armed
144 Sensor tamper Zone A sensor's tamper has been violated (case opened)
145 Expansion module tamper Zone An expansion module's tamper has been violated (cabinet opened)
146 Silent Burglary A burglary zone has been violated while armed with no audible
Zone
notification produced
147 Sensor Supervision Failure A sensor's supervisory circuit has reported a failure while the system
Zone
was armed
150 24 Hour Non-Burglary Zone A non-burglary zone has been faulted
151 Gas detected The gas detector assigned to the specified zone has reported a fault
Zone
condition
152 Refrigeration The refrigeration detector assigned to the specified zone has reported
Zone
a fault condition
153 Loss of heat The temperature detector assigned to the specified zone has reported
Zone
a fault condition
154 Water Leakage The water leak detector assigned to the specified zone has reported a
Zone
fault condition
155 Foil Break The specified zone which is assigned to foil used as glass break
Zone
detection has reported a fault condition
156 Day Trouble The specified zone which monitors trouble by day has reported a fault
Zone
condition while disarmed
157 Low bottled gas level The gas level detector assigned to the specified zone has reported a
Zone
fault condition
158 High temp The over-temperature detector assigned to the specified zone has
Zone
reported a fault condition
159 Low temp The under-temperature detector assigned to the specified zone has
Zone
reported a fault condition
This zone has the capability to emit a chime sound when the control is
160 Awareness Zone Response Zone
in the armed state. Does not alarm, used for alert.
161 Loss of air flow The air flow detector assigned to the specified zone has reported a
Zone
fault condition
162 Carbon Monoxide detected The carbon monoxide detector assigned to the specified zone has
Zone
reported a fault condition
163 Tank level The tank level detector assigned to the specified zone has reported a
Zone
fault condition
168 High Humidity Zone A High Humidity condition has been detected
169 Low Humidity Zone A Low Humidity condition has been detected
200 Fire Supervisory The supervisory circuit of the specified fire zone has reported a fault
Zone
condition
201 Low water pressure The water pressure sensor assigned to the specified zone has
Zone
reported a fault condition
202 Low CO2 The CO2 pressure sensor assigned to the specified zone has
Zone
reported a fault condition
203 Gate valve sensor The gate valve sensor in the fire sprinkler system assigned to the
Zone
specified zone has reported a fault condition
204 Low water level The water level sensor assigned to the specified zone has reported a
Zone
fault condition
205 Pump activated The pump activity detector assigned to the specified zone has
Zone
reported an active condition
206 Pump failure A pump output monitor assigned to the specified zone has reported a
Zone
fault condition
300 System Trouble A general system trouble condition has been reported by the specified
Zone
zone
301 AC Loss AC power loss has been detected at a control or expansion module
Zone
while the system was disarmed
302 Low system battery Zone A battery has failed a load test while the system was disarmed
303 RAM Checksum bad Zone A test of the system's memory has failed
304 ROM checksum bad Zone A test of the system's executable memory has failed
305 System reset Zone The system has reset and restarted
306 Panel programming changed Zone The programmed configuration of the panel has changed
307 Self-test failure Zone The system has failed a self-test
308 System shutdown Zone The system has been shut down and has stopped functioning
309 Battery test failure The system backup battery has failed a load test while the system was
Zone
disarmed
310 Ground fault Zone The panel has detected a ground fault condition
311 Battery Missing/Dead The system has detected that the backup battery is either missing or
Zone
completely discharged.
312 Power Supply Overcurrent The system power supply has reported an excessive current draw
Zone
condition
313 Engineer Reset User The specified service person has issued a system reset
314 Primary Power Supply Failure The system's primary power supply has failed a supervision test.
Zone Radio devices indicate this when the backup battery charging circuit
has failed its supervision test
315 System Trouble N/A to Honeywell Controls (DSC Only)
316 System Tamper The system has been tampered with and may have been
Zone
compromised
317 Control Panel System Tamper The control panel tamper switch has been violated while the system is
Zone
Disarmed
320 Sounder/Relay Zone A trouble condition exists in the system's sounder/relay circuit
321 Bell 1 Zone A trouble condition exists in the primary bell circuit
322 Bell 2 Zone A trouble condition exists in the secondary bell circuit
323 Alarm relay Zone A trouble condition exists in the system's alarm relay circuit
324 Trouble relay Zone A trouble condition exists in the system's trouble relay circuit
325 Reversing relay The specified TELCO reversing relay has reported a trouble condition
Zone
326 Notification Appliance Ckt. # 3 Zone A trouble condition exists in the bell #3 circuit
327 Notification Appliance Ckt. #4 Zone A trouble condition exists in the bell #4 circuit
330 System Peripheral trouble Zone A system peripheral device has reported a trouble condition
331 Polling loop open An open circuit condition has been detected on a polling loop while
Zone
the system was disarmed
332 Polling loop short A short circuit condition has been detected on a polling loop while the
Zone
system was disarmed
333 Expansion module failure A general failure condition has been detected on an expansion
Zone
module while the system was disarmed
334 Repeater failure A repeater in the system has reported a failure condition while the
Zone
system was disarmed
335 Local printer out of paper The printer attached to the panel has reported an Out Of Paper
Zone
condition
336 Local printer failure Zone The printer attached to the panel has reported a failure condition
337 Exp. Module DC Loss Zone An expansion module has detected a DC power loss
338 Exp. Module Low Batt. Zone An expansion module has detected a low battery condition
339 Exp. Module Reset Zone An expansion module has reset
341 Exp. Module Tamper Zone An expansion module has detected its taper switch has been faulted
342 Exp. Module AC Loss Zone An expansion module has detected the loss of AC power
343 Exp. Module self-test fail Zone An expansion module has failed a self-test
344 RF Receiver Jam Detect An RF receiver has detected the presence of a jamming signal,
Zone preventing it from receiving normal signals from the system RF
devices
345 AES Encryption disabled/ enabled E345 AES Encryption has been disabled
Zone
R345 AES Encryption has been enabled
350 Communication trouble The system has experienced difficulties communicating with the
Zone
central station
351 Telco 1 fault Zone The system has detected a fault on the primary dial-up line
352 Telco 2 fault Zone The system has detected a fault on the secondary dial-up line
353 Long Range Radio xmitter fault Zone A fault has been detected in the long range radio subsystem
354 Failure to communicate event The system was unable to communicate an event to the central
Zone
station
355 Loss of Radio supervision Zone The radio has not reported in its designated supervision interval
356 Loss of central polling The radio has detected a loss in the polling signal from it's associated
Zone
receiver
357 Long Range Radio VSWR problem The Long Range Radio has reported a transmitter/antenna problem
Zone
358 Periodic Comm Test Fail /Restore Zone A periodic Communication path test has failed
E359 Comm Fail- Communicator did not check in with AlarmNet
during its supervision interval
359 AlarmNet Communications Failure Zone
P359 Comm Fail Reminder
R359 Comm Fail Restored
360 New Registration A Communicator has been newly registered with AlarmNet
Authorized Substitution
361 An Authorized Substitution Registration was successful
Registration
Unauthorized Substitution
362 An Unauthorized Substitution Registration was blocked - Need PIN
Registration
Module Firmware Update A Firmware update started E365/finished R365 to the Cell
365 Zone
Start/Finish Communicator module
366 Module Firmware Update Failed Zone A Firmware update sent to the Cell Communicator module failed
370 Protection loop Zone The specified protection loop has reported a trouble condition
371 Protection loop open The specified protection loop has reported an open-loop trouble
Zone
condition
372 Protection loop short The specified protection loop has reported a shorted-loop trouble
Zone
condition
373 Fire trouble A fire sensor has detected a trouble condition on the specified zone
Zone
while the system was disarmed
374 Exit error alarm (zone) An exit error condition has been reported for the specified alarm zone
Zone
375 Panic zone trouble Zone The system has detected a trouble condition on the panic zone
376 Hold-up zone trouble Zone The system has detected a trouble condition on the hold-up zone
377 Swinger Trouble A fault has occurred on a zone that has been shut down due to
Zone
excessive alarms
378 Cross-zone Trouble The specified zone in a cross-zone configuration has faulted without a
Zone fault on its corresponding cross-zone in a specific time period

380 Sensor trouble Zone The specified sensor has reported a trouble condition
381 Loss of supervision - RF The specified zone has failed to report in during its designated
Zone
supervision period
382 Loss of supervision - RPM An Remote Polled Module assigned to the specified zone has failed
Zone
supervision
383 Sensor tamper Zone The tamper switch on the specified sensor has been faulted
384 RF low battery The specified battery powered RF zone has reported a low battery
Zone
condition
385 Smoke detector Hi sensitivity Zone A smoke detector's sensitivity level has drifted to the upper limit
386 Smoke detector Low sensitivity Zone A smoke detector's sensitivity level has drifted to the lower limit
387 Intrusion detector Hi sensitivity Zone An intrusion detector's sensitivity level has drifted to the upper limit
388 Intrusion detector Low sensitivity Zone An intrusion detector's sensitivity level has drifted to the lower limit
389 Sensor self-test failure Zone The specified sensor has failed a self-test
391 Sensor Watch trouble A motion sensor has not been triggered within a pre-defined time
Zone
interval
392 Drift Compensation Error Zone A smoke detector cannot automatically adjust its sensitivity
393 Maintenance Alert Zone The specified zone requires maintenance
394 CO Detector needs replacement Zone The specified Carbon Monoxide detector has reached end-of-life
400 Open/Close User The specified user has disarmed/armed the system
401 O/C by user User The specified user has disarmed/armed the system
402 Group O/C User A group of zones has been armed or disarmed
403 Automatic O/C User A partition has been automatically armed or disarmed
404 Late to O/C (Note: use 453 or 454
User
instead )
405 Deferred O/C (Obsolete- do not
User
use )
406 Cancel The specified user has cancelled the previously reported alarm
User
condition
407 Remote arm/disarm The specified user has armed or disarmed the system from off-
User
premises
408 Quick arm User The specified user has quick-armed the system
409 Keyswitch O/C The specified user has armed or disarmed the system using a
User
keyswitch
411 Callback request made User A remote site (central station) has requested the panel call it back
412 Successful download/access The configuration data of the system has been successfully
User
downloaded
413 Unsuccessful access A number of failed attempts have been made to remotely access the
User
system
414 System shutdown command A central station has sent a system shutdown command to the panel
User
received
415 Dialer shutdown command A central station has sent a dialer shutdown command to the panel
User
received
416 Successful Upload The configuration data of the system has been successfully uploaded
Zone
418 Remote Cancel The specified user has remotely cancelled the previously reported
User
alarm condition
419 Remote Verify The specified user has remotely verified the previously reported alarm
User
condition
421 Access denied User The access control system has denied access to the specified user
422 Access report by user User
423 Forced Access Zone The specified access control door has been forced open
424 Egress Denied User The access control system has denied egress to the specified user
425 Egress Granted The access control system has granted egress for the specified user
User
426 Access Door propped open Zone The specified access control door has been held open
427 Access point Door Status Monitor The specified Access Point's Door Status Monitor has reported a
Zone
trouble trouble condition to the panel
428 Access point Request To Exit The specified Access Point's Request To Exit zone has reported a
Zone
trouble trouble condition to the panel
429 Access program mode entry User The access control system has been put into program mode
430 Access program mode exit User The access control system has exited program mode
431 Access threat level change User The access control system's threat level has been changed
432 Access relay/trigger fail The specified access control output device has failed to operate
Zone
properly
433 Access RTE shunt The specified Request To Exit zone has been shunted and will no
Zone
longer report activity
434 Access DSM shunt The specified Door Status Monitor zone has been shunted and will no
Zone
longer report activity
435 Second Person Access A second person has accessed an access point conforming to Two-
User
Man-Rule requirements
436 Irregular Access User
441 Armed STAY User The specified user has armed the system in STAY mode
442 Keyswitch Armed STAY The specified user has armed the system in STAY mode using a
User
keyswitch
443 Armed with System Trouble The specified user has armed the system while overriding a trouble
User
Override condition
450 Exception O/C The system has been armed or disarmed outside of the configured
User
time window
451 Early O/C The system has been disarmed/armed by the specified user before
User
the configured time window has started
452 Late O/C The system has been disarmed/armed by the specified user after the
User
configured time window has ended
453 Failed to Open The system has failed to have been disarmed during the designated
User
time window
454 Failed to Close The system has failed to be armed during the designated time window
User
455 Auto-arm Failed The system has failed to automatically arm itself at the designated
User
time
456 Partial Arm User The system has been only partially armed by the specified user
457 Exit Error (user) The specified user has made an error exiting the premises after
User
arming the system
458 User on Premises User A user has disarmed the system after an alarm has occurred
459 Recent Close User The system had been armed within the last xx minutes
461 Wrong Code Entry Zone
462 Legal Code Entry User
463 Re-arm after Alarm User
464 Auto-arm Time Extended A user has successfully requested that the system delay automatically
User
arming
465 Panic Alarm Reset Zone The specified panic zone has been reset
466 Service On/Off Premises User A service person has entered or left the premises
501 Access reader disable The credential reader on the specified access point has been disabled
Zone
520 Sounder/Relay Disable Zone The specified sounder or relay has been disabled
521 Bell 1 disable Zone The specified output for Bell 1 has been disabled
522 Bell 2 disable Zone The specified output for Bell 2 has been disabled
523 Alarm relay disable Zone The specified alarm relay has been disabled
524 Trouble relay disable Zone The specified trouble relay has been disabled
525 Reversing relay disable Zone The specified reversing relay has been disabled
526 Notification Appliance Ckt. # 3 The specified output for Bell 3 has been disabled
Zone
disable
527 Notification Appliance Ckt. # 4 The specified output for Bell 4 has been disabled
Zone
disable
531 Module Added Zone The specified access control module has been added to the system
532 Module Removed The specified access control module has been removed from the
Zone
system
551 Dialer disabled Zone The specified dialer has been disabled
552 Radio transmitter disabled Zone The specified radio transmitter has been disabled
553 Remote Upload/Download Remote configuration has been enabled
Zone
disabled
570 Zone/Sensor bypass Zone The specified zone or sensor has been bypassed
571 Fire bypass Zone The specified fire zone has been bypassed
572 24 Hour zone bypass Zone The specified 24 hour zone has been bypassed
573 Burg. Bypass Zone The specified burglary zone has been bypassed
574 Group bypass User A group of zones has been bypassed
575 Swinger bypass The specified zone which has reported an excessive number of
Zone
faults/restores in a short period of time has been bypassed
576 Access zone shunt The specified zone in the access control system has been shunted
Zone
and will no longer report activity
577 Access point bypass The specified access point in the access control system has been
Zone
bypassed and will allow the door to open (unsecured)
578 Vault Bypass Zone The specified vault zone has been bypassed
579 Vent Zone Bypass The specified vent zone has been bypassed and will no longer report
Zone
any activity
601 Manual trigger test report Zone A test report has been triggered manually
602 Periodic test report Zone A periodic test report has been triggered
603 Periodic RF transmission Zone A periodic RF path test report has been triggered
604 Fire test User The specified user has initiated a test of the fire alarm zones
605 Status report to follow Zone
606 Listen-in to follow Zone The system is about to activate a 2-way audio session
607 Walk test mode The specified user has placed the system into the walk-test mode for
User
testing purposes
608 Periodic test - System Trouble A periodic test has been triggered but the fire system has a trouble
Zone
Present condition present
609 Video Xmitter active Zone A video look-in session is about to begin
611 Point tested OK Zone The specified point tested successfully
612 Point not tested Zone The specified point has not been tested
613 Intrusion Zone Walk Tested Zone The specified intrusion zone has been successfully walk-tested
614 Fire Zone Walk Tested Zone The specified fire zone has been successfully walk-tested
615 Panic Zone Walk Tested Zone The specified panic zone has been successfully walk-tested
616 Service Request Zone A request has been made for system servicing
621 Event Log reset The event log has been reset and all stored events have been
Zone
discarded
622 Event Log 50% full Zone The event log is 50% full
623 Event Log 90% full Zone The event log is 90% full
624 Event Log overflow Zone The event log has overflowed and events have been lost
625 Time/Date reset The time and date have been reset to a new value by the specified
User
user
626 Time/Date inaccurate Zone The system time and date is known to be in error
627 Program mode entry Zone The system has been placed into program mode
628 Program mode exit Zone The system has exited program mode
629 32 Hour Event log marker Zone
630 Schedule change Zone The specified fire/burglary schedule has been changed
631 Exception schedule change The time schedule for event reporting by exception has been changed
Zone
632 Access schedule change Zone The specified access control schedule has been changed
641 Senior Watch Trouble Zone A person has not activated a motion sensor in a specified period
642 Latch-key Supervision User A child has disarmed the system (after school)
643 Restricted Door Opened Zone A restricted door has been opened / closed
645 Help Arrived Requested help personnel have arrived on the scene
646 Addition Help Needed Addition help personnel are requested
647 Addition Help Cancel Addition help personnel are no longer required
651 Reserved for Ademco Use Zone
652 Reserved for Ademco Use User
653 Reserved for Ademco Use User
654 System Inactivity Zone System has not been operated for x days
655 User Code X modified by Installer User The Installer has modified the specified User's code
703 Auxiliary #3 Zone
704 Installer Test Zone
750 User Assigned
751 User Assigned
752 User Assigned
753 User Assigned
754 User Assigned
755 User Assigned
756 User Assigned
757 User Assigned
758 User Assigned
759 User Assigned
760 User Assigned
761 User Assigned
762 User Assigned
763 User Assigned
764 User Assigned
765 User Assigned
766 User Assigned
767 User Assigned
768 User Assigned
769 User Assigned
770 User Assigned
771 User Assigned
772 User Assigned
773 User Assigned
774 User Assigned
775 User Assigned
776 User Assigned
777 User Assigned
778 User Assigned
779 User Assigned
780 User Assigned
781 User Assigned
782 User Assigned
783 User Assigned
784 User Assigned
785 User Assigned
786 User Assigned
787 User Assigned
788 User Assigned
789 User Assigned
796 Unable to output signal (Derived
Zone
Channel)
798 STU Controller down (Derived
Zone
Channel)
900 Download Abort Download The specified Downloader ID has aborted a download sequence in
er ID progress
901 Download Start/End Download Downloader has started or ended a download sequence to the panel
er ID
902 Download Interrupted Download A download sequence has been interrupted
er ID
903 Device Flash Update Started/ Device A code update for a devices application firmware has started (E903)
Completed Zone or completed successfully (R903)
904 Device Flash Update Failed Device A code update for a devices application firmware has failed
Zone
910 Auto-close with Bypass An auto-close sequence has been started and the specified zone has
Zone
been bypassed
911 Bypass Closing Zone
912 Fire Alarm Silence Zone The fire alarm has been silenced
913 Supervisory Point test Start/End User A fire supervisory device has been tested
914 Hold-up test Start/End User The specified user has started or ended a hold-up test
915 Burg. Test Print Start/End User The printed progress of a burglary test has been started or ended
916 Supervisory Test Print Start/End The printed progress of a supervisory test has been started or ended
User
917 Burg. Diagnostics Start/End Zone A burglary system diagnostic test has been started or ended
918 Fire Diagnostics Start/End Zone A fire system diagnostic test has been started or ended
919 Untyped diagnostics Zone
920 Trouble Closing (closed with burg.
User
during exit)
921 Access Denied Code Unknown Access has been denied because the system did not recognize the
User
supplied access code as valid
922 Supervisory Point Alarm Zone The specified supervisory point has reported an alarm condition
923 Supervisory Point Bypass Zone The specified supervisory point has been bypassed
924 Supervisory Point Trouble Zone The specified supervisory point has reported a trouble condition
925 Hold-up Point Bypass Zone The specified hold-up point has been bypassed
926 AC Failure for 4 hours Zone There has been a loss of AC power for at least four hours
927 Output Trouble Zone The specified output has reported a trouble condition
928 User code for event This message contains the ID of the user who triggered the previous
User
event
929 Log-off User The specified user has logged-off of the system

954 CS Connection Failure Zone The specified CS connection has failed/restored

961 Rcvr Database Connection The connection to the receiver's database has failed/restored
Zone
Fail/Restore
962 License Expiration Notify Zone The product license has been terminated (7810PC)
999 1 and 1/3 Day No Read Log In the last 31.9 hours (1 and 1/3 days), nothing has been posted to the
event log. There is nothing new to read. Does not send to central
station and only occurs in the Vista-20/SE and FA sister products.

You might also like