Tapis Pump Data Sheets Revision 2
Tapis Pump Data Sheets Revision 2
Technical data 3
GTA 1x1x6 CA1
TAG NO: Tapis F Receiver From
Company name Oliv er Equipment Company HMD Kontro Seal/Less Pumps
Department Sales Internal Sales
Issued by Greg, Lucas Phil, Gallo
Phone number +1 713 856 9206 +44 1323 452088
Fax no. +1 713 856 8305 +44 1323 503369
e-mail address glucas@oliv erequip.com [email protected]
Power data ref erred to: Condensate [100%] ; 30°C; 0.683kg/dm³; 1.22mm²/s
[m] Head
Application range
58
10%
56
20%
54
52 30%
50
35%
48 Eff.
35.6%
46
44
42
40
Ø 169
38
37.3 m
36
1
34
32
29.8%
30
28
Ø 140
26
24
25.5%
22
20 Ø 120
18
Efficiency shell curves include magnetic coupling losses
[kW]
Shaft power P2 Ø 169 (P2)
2.8
2.4 Ø 169 (P2)
2 Ø 140 (P2)
1.6 1.54 kW
Ø 120 (P2) Ø 140 (P2)
1.2
Ø 120 (P2)
0.8
0.4
0
[%] Efficiency
40 Ø 169
Ø 120 Ø 140
35
Ø 169
30
Ø 140
25 Ø 120
20
18.2 %
15
10
5
[m] NPSH-values
Ø 120 Ø 169
8
7
6
5
4
3.42 m
3
2
1
4.07 m³/h
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 [m³/h]
Dimensions in mm
a 105
B3 350
B5 400
d1 14
f 196
h1 239
h2 160
h5 12
L1 366
L2 104
L3 300
L8 33
ML 291
MTL 173
MTR 173
MTT 173
R 250
Power data ref erred to: Condensate [100%] ; 25°C; 0.583kg/dm³; 0.206mm²/s
Head
[m]
Application range
58
56 10%
54 20%
52
25%
50
48 Eff.
27%
46
44
42
40
Ø 169
38 37.5 m
36
1
34
32
30 20.9%
28
Ø 140
26
24
22
16.2%
20 Ø 120
18
Efficiency shell curves include magnetic coupling losses
[kW] Shaft power P2
Ø 169 (P2)
2.8
2.4
Ø 140 (P2) Ø 169 (P2)
2 1.97 kW
Ø 120 (P2)
1.6
Ø 140 (P2)
1.2
Ø 120 (P2)
0.8
[%] Efficiency
35 Ø 169
Ø 140
30 Ø 120
25 Ø 169
20 Ø 140
15 Ø 120
12.3 %
10
5
0
[m] NPSH-values Ø 169
Ø 120 Ø 140
8
7
6
5
4
3.29 m
3 4.08 m³/h
0 1 2 3 4 5 6 7 8 9 10 11 12 13 [m³/h]
Dimensions in mm
a 155
B2 350
B3 400
d 14
f 236
H 239
h2 200
h5 12
L1 306
L2 34.5
L3 230
L5 72
ML 291
MTL 173
MTR 173
MTT 173
R 150