0% found this document useful (0 votes)
157 views6 pages

Design of Isolated Footing 1: Calculations

1. The document provides the design details of an isolated footing for a two-storey residential building located in Calamba. 2. Key details include the geometrical properties, material properties, loading conditions, and calculations to check shear stress and reinforcement requirements. 3. The design summary shows that the required and provided dimensions of the footing meet requirements, and checks of one-way shear stress and reinforcement are within allowable limits.

Uploaded by

Mikhail Tabucal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
157 views6 pages

Design of Isolated Footing 1: Calculations

1. The document provides the design details of an isolated footing for a two-storey residential building located in Calamba. 2. Key details include the geometrical properties, material properties, loading conditions, and calculations to check shear stress and reinforcement requirements. 3. The design summary shows that the required and provided dimensions of the footing meet requirements, and checks of one-way shear stress and reinforcement are within allowable limits.

Uploaded by

Mikhail Tabucal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

Made Date Sheet

03-Apr-20 1
Check Date Rev.
04-Apr-20 0
PROJECT TITLE: TWO-STOREY RESIDENTIAL BUILDING
LOCATION: Calamba
DESIGN OF ISOLATED FOOTING 1
Geometrical Properties Material Properties
Depth of Soil overburden 1 m Weight of soil "γsoil" 17 kN/m3
Thickness of plain concrete 0 mm Weight of plain concrete "γpc" 24 kN/m3
Thickness of Slab on garde 0 mm Weight of reinforced concrete "γrc" 24 kN/m3
Depth of Column "D" 400 mm Safe bearing pressure "q" 105 kN/m2
Width of Column "B" 150 mm Eff. Net bearing pressure "qnet" 86.25 kN/m2
Required Area of footing 1 m2 Strength of concrete "fc" 21 N/mm2
Required Length of footing 1.07 m Strength of steel "fy" 275 N/mm2
Required Width of footing 0.82 m Clear cover to concrete 75 mm
Provided Length of footing "L" 1.1 m Dia of rebar 16 mm
Provided Width of footing "W" 1.1 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 1.21 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 250 mm αs, constant depend on column location 20 Edge
Length of plain concrete 1.07 m Loading
Width of plain concrete 0.82 m Floor Finish on SOG 0 kN/m2
Live load on SOG 0 kN/m2
Reinforcement Service Dead Load "Pdl" 55 kN
Type of Reinforcement No. Area Service Live Load "Pll" 20 kN
Bottom Reinforcement Long dir. 3 603.1872 Live load reduction factor 1
Bottom Reinforcement Short dir. 3 603.1872 Total Serivce Load "Ptot" 75 kN
Total Ultimate Load "Pu,tot" 98 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 0 kN/m2 REQUIRED DIMENSIONS 1.07 0.82 250
Soil overburden 17 kN/m2 PROVIDED DIMENSIONS 1.1 1.1 250
Adjust for Concrete 1.75 kN/m2
Total surcharge 18.75 kN/m2
Ult. press under RC base "pu" 111.69364 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.585 N/mm2
Effective dept "d1" short dir 167.00 mm
Effective dept "d2" long dir 151.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 18.76453 kN/m
Shear stress short dir. 0.11 N/mm2 O.K < 0.585 N/mm2
Shear long dir /m 20.55 kN/m
Shear stress long dir. 0.14 N/mm2 O.K < 0.585 N/mm2
Made Date Sheet
0 03-Apr-20 2
Check Date Rev.
0 04-Apr-20 0
PROJECT TITLE: TWO-STOREY RESIDENTIAL BUILDING
LOCATION: Calamba
DESIGN OF ISOLATED FOOTING 1
````
Average effective depth "dav" 159.00 mm
Shear perimeter "bo" 1736.00 mm
Allowable shear stress is least of:
a) vc = Φ*1+(2/βc)√f'c 1.02 N/mm2
6
b) vc = Φ*0.083*(αs*dav/bo + 2)√f'c 1.09 N/mm2

c) vc = Φ* 0.33*√f'c 1.13 N/mm2

Therefore allowable shear stress vc = 1.02 N/mm2


Effective shear force at perimeter 78.70705 kN
Actual shear stress 0.29 N/mm2 O.K < 1.02 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 13.86048 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L

Ast = 357.85 mm2


Ast,min = 0.0018*L*H 495 mm2
Hence Provide Ast = 495.00 mm2
Provide16mm dia 3 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2β/(1+β)
Therefore β = L / W 1.00
Therefore revised reinforcement 3 No of bars dia 16 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 6.89415 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85*Φ*f'c*W

Ast = 176.56 mm2

Ast,min = 0.0018*W*H 495 mm2


Hence Provide Ast = 495.00 mm2

Provide16mm dia 3 No. of Bars


Made Date Sheet
03-Apr-20 1
Check Date Rev.
04-Apr-20 0
PROJECT TITLE: Two Storey Residential Building
LOCATION: Calamba
DESIGN OF ISOLATED FOOTING 2
Geometrical Properties Material Properties
Depth of Soil overburden 1 m Weight of soil "γsoil" 17 kN/m3
Thickness of plain concrete 0 mm Weight of plain concrete "γpc" 24 kN/m3
Thickness of Slab on garde 125 mm Weight of reinforced concrete "γrc" 24 kN/m3
Depth of Column "D" 400 mm Safe bearing pressure "q" 105 kN/m2
Width of Column "B" 150 mm Eff. Net bearing pressure "qnet" 83.25 kN/m2
Required Area of footing 1 m2 Strength of concrete "fc" 21 N/mm2
Required Length of footing 0.95 m Strength of steel "fy" 275 N/mm2
Required Width of footing 0.7 m Clear cover to concrete 75 mm
Provided Length of footing "L" 1 m Dia of rebar 16 mm
Provided Width of footing "W" 1 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 1 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 250 mm αs, constant depend on column location 20 Edge
Length of plain concrete 0.95 m Loading
Width of plain concrete 0.95 m Floor Finish on SOG 0 kN/m2
Live load on SOG 0 kN/m2
Reinforcement Service Dead Load "Pdl" 35 kN
Type of Reinforcement No. Area Service Live Load "Pll" 20 kN
Bottom Reinforcement Long dir. 3 603.1872 Live load reduction factor 1
Bottom Reinforcement Short dir. 3 603.1872 Total Serivce Load "Ptot" 55 kN
Total Ultimate Load "Pu,tot" 74 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 3 kN/m2 REQUIRED DIMENSIONS 0.95 0.7 250
Soil overburden 17 kN/m2 PROVIDED DIMENSIONS 1 1 250
Adjust for Concrete 1.75 kN/m2
Total surcharge 21.75 kN/m2
Ult. press under RC base "pu" 111.278195 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.585 N/mm2
Effective dept "d1" short dir 167.00 mm
Effective dept "d2" long dir 151.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 12.01805 kN/m
Shear stress short dir. 0.07 N/mm2 O.K < 0.585 N/mm2
Shear long dir /m 13.80 kN/m
Shear stress long dir. 0.09 N/mm2 O.K < 0.585 N/mm2
Made Date Sheet
0 03-Apr-20 2
Check Date Rev.
0 04-Apr-20 0
PROJECT TITLE: Two Storey Residential Building
LOCATION: Calamba
DESIGN OF ISOLATED FOOTING 2
````
Average effective depth "dav" 159.00 mm
Shear perimeter "bo" 1736.00 mm
Allowable shear stress is least of:
a) vc = Φ*1+(2/βc)√f'c 1.02 N/mm2
6
b) vc = Φ*0.083*(αs*dav/bo + 2)√f'c 1.09 N/mm2

c) vc = Φ* 0.33*√f'c 1.13 N/mm2

Therefore allowable shear stress vc = 1.02 N/mm2


Effective shear force at perimeter 54.77881 kN
Actual shear stress 0.20 N/mm2 O.K < 1.02 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 10.04981 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L

Ast = 258.62 mm2


Ast,min = 0.0018*L*H 450 mm2
Hence Provide Ast = 450.00 mm2
Provide16mm dia 3 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2β/(1+β)
Therefore β = L / W 1.00
Therefore revised reinforcement 3 No of bars dia 16 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 4.207707 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85*Φ*f'c*W

Ast = 107.48 mm2

Ast,min = 0.0018*W*H 450 mm2


Hence Provide Ast = 450.00 mm2

Provide16mm dia 3 No. of Bars


Made Date Sheet
03-Apr-20 1
Check Date Rev.
04-Apr-20 0
PROJECT TITLE: Two Storey Residential Building
LOCATION: Ponte Verde, Sto Tomas for Mr and Mrs Felicisimo M. Sumaya
DESIGN OF ISOLATED FOOTING 1
Geometrical Properties Material Properties
Depth of Soil overburden 1 m Weight of soil "γsoil" 18 kN/m3
Thickness of plain concrete 0 mm Weight of plain concrete "γpc" 24 kN/m3
Thickness of Slab on garde 0 mm Weight of reinforced concrete "γrc" 24 kN/m3
Depth of Column "D" 350 mm Safe bearing pressure "q" 105 kN/m2
Width of Column "B" 200 mm Eff. Net bearing pressure "qnet" 80.4 kN/m2
Required Area of footing 1 m2 Strength of concrete "fc" 24 N/mm2
Required Length of footing 1.2 m Strength of steel "fy" 275 N/mm2
Required Width of footing 1.15 m Clear cover to concrete 75 mm
Provided Length of footing "L" 1.2 m Dia of rebar 16 mm
Provided Width of footing "W" 1.2 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 1.44 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 300 mm αs, constant depend on column location 20 Edge
Length of plain concrete 1.2 m Loading
Width of plain concrete 1.15 m Floor Finish on SOG 2.4 kN/m2
Live load on SOG 2.4 kN/m2
Reinforcement Service Dead Load "Pdl" 75 kN
Type of Reinforcement No. Area Service Live Load "Pll" 35 kN
Bottom Reinforcement Long dir. 4 804.2496 Live load reduction factor 1
Bottom Reinforcement Short dir. 4 804.2496 Total Serivce Load "Ptot" 110 kN
Total Ultimate Load "Pu,tot" 146 kN

Calculations DESIGN SUMMARY


1. Calculate revised size of foundation L, Met W,Met H,mm
Self wt. of SOG 0 kN/m2 REQUIRED DIMENSIONS 1.2 1.15 300
Soil overburden 18 kN/m2 PROVIDED DIMENSIONS 1.2 1.2 300
Adjust for Concrete 1.8 kN/m2
Total surcharge 24.6 kN/m2
Ult. press under RC base "pu" 105.797101 kN/m2
`
2. Check one way shear
Allowable shear stress vc=0.75*0.17*sqrt(fc') 0.625 N/mm2
Effective dept "d1" short dir 217.00 mm
Effective dept "d2" long dir 201.00 mm
Shear is checked at "d" from column face ```
Shear short dir /m 22.0058 kN/m
Shear stress short dir. 0.10 N/mm2 O.K < 0.625 N/mm2
Shear long dir /m 28.99 kN/m
Shear stress long dir. 0.14 N/mm2 O.K < 0.625 N/mm2
Made Date Sheet
0 03-Apr-20 2
Check Date Rev.
0 04-Apr-20 0
PROJECT TITLE: Two Storey Residential Building
LOCATION: Ponte Verde, Sto Tomas for Mr and Mrs Felicisimo M. Sumaya
DESIGN OF ISOLATED FOOTING 1
````
Average effective depth "dav" 209.00 mm
Shear perimeter "bo" 1936.00 mm
Allowable shear stress is least of:
a) vc = Φ*1+(2/βc)√f'c 1.34 N/mm2
6
b) vc = Φ*0.083*(αs*dav/bo + 2)√f'c 1.27 N/mm2

c) vc = Φ* 0.33*√f'c 1.21 N/mm2

Therefore allowable shear stress vc = 1.21 N/mm2


Effective shear force at perimeter 121.8115 kN
Actual shear stress 0.30 N/mm2 O.K < 1.21 N/mm2

4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 15.86957 kN-m

0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L

Ast = 309.36 mm2


Ast,min = 0.0018*L*H 648 mm2
Hence Provide Ast = 648.00 mm2
Provide16mm dia 4 No. of Bars
For rectangular footings and inorder to keep uniform spacing of reinforcement ACI 318 Cl. 15.4.4.2
increase area of steel by 2β/(1+β)
Therefore β = L / W 1.00
Therefore revised reinforcement 4 No of bars dia 16 mm
Long direction:
Mu long = pu*W*((L-D)/2)2/2 11.46576 kN-m

Ast = 0.85f'c*W d - d2 - 2Mu


fy 0.85*Φ*f'c*W

Ast = 222.99 mm2

Ast,min = 0.0018*W*H 648 mm2


Hence Provide Ast = 648.00 mm2

Provide16mm dia 4 No. of Bars