Design of Isolated Footing 1: Calculations
Design of Isolated Footing 1: Calculations
03-Apr-20 1
Check Date Rev.
04-Apr-20 0
PROJECT TITLE: TWO-STOREY RESIDENTIAL BUILDING
LOCATION: Calamba
DESIGN OF ISOLATED FOOTING 1
Geometrical Properties Material Properties
Depth of Soil overburden 1 m Weight of soil "γsoil" 17 kN/m3
Thickness of plain concrete 0 mm Weight of plain concrete "γpc" 24 kN/m3
Thickness of Slab on garde 0 mm Weight of reinforced concrete "γrc" 24 kN/m3
Depth of Column "D" 400 mm Safe bearing pressure "q" 105 kN/m2
Width of Column "B" 150 mm Eff. Net bearing pressure "qnet" 86.25 kN/m2
Required Area of footing 1 m2 Strength of concrete "fc" 21 N/mm2
Required Length of footing 1.07 m Strength of steel "fy" 275 N/mm2
Required Width of footing 0.82 m Clear cover to concrete 75 mm
Provided Length of footing "L" 1.1 m Dia of rebar 16 mm
Provided Width of footing "W" 1.1 m Flexure strength reduction factor 0.9
Provided area of footing "Af" 1.21 m2 Shear strength reduction factor 0.75
Provided Depth of Footing "H" 250 mm αs, constant depend on column location 20 Edge
Length of plain concrete 1.07 m Loading
Width of plain concrete 0.82 m Floor Finish on SOG 0 kN/m2
Live load on SOG 0 kN/m2
Reinforcement Service Dead Load "Pdl" 55 kN
Type of Reinforcement No. Area Service Live Load "Pll" 20 kN
Bottom Reinforcement Long dir. 3 603.1872 Live load reduction factor 1
Bottom Reinforcement Short dir. 3 603.1872 Total Serivce Load "Ptot" 75 kN
Total Ultimate Load "Pu,tot" 98 kN
4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 13.86048 kN-m
0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L
4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 10.04981 kN-m
0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L
4. Reinforcement Calculation
Short direction:
Mu short = pu*L*((W-B)/2)2/2 15.86957 kN-m
0.85f'c*L d - d2 - 2Mu
Ast = fy 0.85*Φ*f'c*L