80006oth Valv Slipin

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

SLIP-IN CARTRIDGE INSERT VALVES & OPERATORS

OILGEAR TOWLER, S.A.


Entidad Zikuñaga, 62
20.120 HERNANI (Gipuzkoa)
phone: (+34) 943 552 700
E-mail: [email protected]
INTRODUCTION & FEATURES IN BRIEF

OPERATOR HEAD

General Features
SPACER
1. 350 bar service.
2. Sizes from DIN 016 to DIN 100.
3. Slip-in cartridge insert valves can
provide the following functions: SPRING
a) Check valve.
b) Flow control.
c) Pressure regulating.
d) Directional control.
e) Decompression control.
f) Special combinations. PLUNGER

4. A single cartridge can provide more


than one function with proper
operator circuiting. BUSHING
5. Cartridges of the same size but
different ratios are interchangeable.
6. Cartridges are small, compact and
handle high flow rates.
7. Individual cartridges can be sized to MANIFOLD
satisfy circuit flow rates.
8. Different size cartridges (with
spacers) can be designed into a
common manifold eliminating
necessity for angular drilling.
9. Cartridges can be installed in a
manifold at right angles to each other
or even reversed from standard
position to simplify manifold
machining.

Insert Construction Features Figure 2. Cross Section of Typical Slip-in Cartridge Insert Valve

1. Low pressure drop due to streamline flow through


valve.
2. Fast response because of small control volume
necessary.
Operator Features
3. Poppet type seat minimizes leakage.
4. Available with or without throttling nose.
1. Operators for insert valves of
5. Different plunger area ratios are available to provide
the same size are
various functions.
interchangeable.
6. Side loads on bushing are eliminated through use of
2. Test stations and orifices are
spacer.
in operator heads.
7. Various length spacers available simplify manifold
3. Operator heads for various
layout and machining.
control valves are offered.
8. Various springs are available to provide different
cracking pressures.
9. Back-up rings are used with O-ring seals to insure long
seal life.

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
OPERATION OF SLIP-IN CARTRIDGE INSERT VALVES

Figure 4. port A area(A A) is unity (1.0), Figure 5. port A area(A A) is unity (1.0), Figure 6. port A area(A A) is unity (1.0),
effective Pot B area (AB) is zero. effective Pot B area (AB) is half of port effective Pot B area (AB) is same as
Therefore, top plunger area AW is 1 + A area (0.5). Therefore, top plunger port A area (1.0). Therefore, top
0 = 1. Ratio of this valve plunger is area A W is 1.0 + 0.5 = 1.5. Ratio of this plunger area AW is 1.0 + 1.0 = 2.0.
expressed as 1:1. valve plunger is expressed as 1:1.5. Ratio of this valve plunger is
expressed as 1:2.

PILOT CONTROL
PRESSURE PLUS SPRING
FORCE ACTS ON FULL Ratios — What are they?
AREA AW.
Opening and closing of the valve is a function of force
balances on three areas; AA, AB and AW . Pressures in
areas AA and effective area AB tend to open the
plunger. Spring force and pressure acting on area AW
tend to close the plunger.

NOTE: Area AA is always considered “unity” (1.0) and


area Aw is the sum of areas AA and AB.

Valves with a 1:1 ratio are primarily used to regulate


pressure. Valves with a 1:1.5 ratio are primarily used
as pilot operated check valves, directional control
valves and (when used with stroke limiter option) flow
control valves. Valves with a 1:2 ratio are sometimes
used as directional valves when it is necessary that
flow characteristics be the same in either direction.

Cushion Nose Plungers


SYSTEM PRESSURE AT
PORT B Valve plungers are also available
ACTS ON AREA AB. with a tapered “cushion nose”. This
nose provides gradual opening and
closing of flow passage to pressure
for descompression control and
smooth operation of hydraulic
SYSTEM PRESSURE AT system. When used with stroke
PORT A limiting option, it provides a very
ACTS ON AREA AA.
fine flow adjustment.

Figure 3. Valve Operating Areas. Figure 7. Cushion Nose Plunger

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
CARTRIDGE SPECIFICATIONS

Type PE - A (not progressive) Type PE - A (not progressive)


016 / 025 / 032 040 / 050 / 063
10 10

9 9

Pressure drop (bar)


Pressure drop (bar)

8 8
016

7 7

040
6 6
032

050
5 5

4
025 4

3
06
3 3

2 2
LIMIT
1 LIMIT 1

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

Flow (l/min) Flow (l/min)


Type PE - A (not progressive) Type SE - A 1.5 / 2.0 (not progressive)
080 / 100 016 / 025 / 032
10
10

9
9
Pressure drop (bar)
Pressure drop (bar)

8
8

7
7

6
6
080

5 5
016
0
10

2
03
025

4 4

3 3

2 LIMIT 2

1 1

0
0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
0 1500 3000 4500 6000 7500 9000 10500 12000 13500 15000 16500 18000

Flow (l/min)
Flow (l/min)
Type SE - A 1.5 / 2.0 (not progressive) Type SE - A 1.5 / 2.0 (not progressive)
040 / 050 / 063 080 / 100
10 10

9 9
Pressure drop (bar)

Pressure drop (bar)

8 8

7 7

6 6
080
040

100

5 5
050

4 4

3
3
06 3

2 2

1 1

0
0
0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000

Flow (l/min) Flow (l/min)

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
CARTRIDGE SPECIFICATIONS

Type SE - B ( progressive) Type SE - B ( progressive)


016 / 025 / 032 040 / 050 / 063

10 10

9 9
Pressure drop (bar)

Pressure drop (bar)


8 8
7
7
016

6
025

040
5
5

050
4
2 3
3
03 4 06
3
2

1 2

0 1
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
0
Flow (l/min) 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600

Flow (l/min)

Type SE - B ( progressive)
080 / 100

10

8
Pressure drop (bar)

7
080

100

0
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000

Flow (l/min)

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
HOW TO ORDER SLIP- IN CARTRIDGE INSERT ASSEMBLIES

Explanation

Example: S E 040 - X A 1.5 / 3 P

Application
S = Standard 350 bar Omit = Standard
service E = Piston with
Z = Special, write out seals
description
L = Pressure reducer
function O-ring material
P = Relief valve function P = Perbunan (std.)
V = Viton (std. in PE
cartridges)
Design
E = Standard cartridge insert Spring number
valve per DIN 24342 standards See table

Choke (Only for S application) Plunger Area Ratios (See page 3)


Omit = Without choke (std.) 1.0= 1:1
W = With choke 1.5= 1:1.5
2.0= 1:2
0.94=0.94:1 (Only SE type)
Size Omit = type L
016, 025, 032, 040, 050, 063, 080, 100 Note: Cartridges PE only 1:0

Series Plunger type (See page 3)


X (last version will be delivered) A = Not progressive
B = Progressive
Omit = Type L

Cracking pressure for all sizes


Spring Number
Direction No Spring Standard LE PE
at Flow 0 1 2 3 4 5
bar bar bar bar bar bar
A 0 0.31 0.62 1.24 4
B 0 0.48 0.96 1.93
C 0 0.62 1.24 2.48
D 0 0.96 1.93 3.86

1:1 1:1.5 1:2

D C
SE
A B C

1:1 1:1.5 1:2

D C SEW

A B C

LE

Bulletin 80.006-OTH-I
6 Rev.:1 April, 2008
DIMENSION FOR INSERTING CARTRIDGE VALVE
MIN. DEPTH OF FINISH
W A

D1 15°

A
NOTES:

T7
E

-Pilot valve may exceed B1 & B2 dimensions.

-The location of working port B (D4) may be anywhere within the location of T1-

T5
T5 as long as the minimum shoulder length T9 is maintained. The center line of
T4

working port B may be arranged at other angles than 90º with respect to D1

T1
X.
B

MA

15°

T2
D4

R2

T8
-The depth and angles of the pilot connections are arranged by the function and
X

location of the valves in the manifold. (D7)


MA
R1

T3

-Recommended thread engagement for ferrous materials (T6 y T11).


T9

D3
U E

MIN. DEPTH OF FINISH


D2
INSTALLATION DIMENSIONS
B2
SECCION A'-A" PER DIN 24 342-C & N.F.P.A.
M
T11
M2 M2 M/2
T6
SIZES 80 THRU 200
M4
Z2
X

B
A"

D6

D5
M3

A'
M5

Y X
M1

D7
B2

22.5°

T10 PORT A: WORKING PORT


Z2

Z1

A"
PORT B: WORKING PORT
D5
M3

PORT B1: OPTIONAL WORKING


PORT X: PILOT SUPLY

A'
45

Z1 PORT Y: PILOT DRAIN


Y

D5 PORT Z1: ADDITIONAL PILOT


35°
M1 CONNECTION PREFERRED
INSTALLATION DIMENSIONS PILOT SUPPLY
PER DIN 24 342-C & N.F.P.A. PORT Z2: ADDITIONAL PILOT
CONNECTION PREFERRED
SIZES 16 THRU 100 PILOT DRAIN

Figure 9. Installation Dimensions (cavity bore, port and thread size) for size 016 through size 100. (510980-1).

D1 D2 D3 D4 D5 D7 M M1 M2 M3 M4 M5
VALVE SIZE B B1 B2 H7 H7
D6 H13 ±0.1 ±0.1 ±0.1 ±0.1 ±0.2 ±0.2
MIN MAX MIN MAX MAX

016 63.5 63.5 32 25 16 19 16 25 4 M8 4 46 25 25 23 10.5

025 85.8 85.8 45 34 25 27 25 32 6 M12 6 58 33 33 29 16

032 101.6 101.6 60 45 32 37 32 40 8 M16 6 70 41 41 35 17

040 124 124 75 55 40 44 40 50 10 M20 6 85 50 50 42.5 23

050 139.7 139.7 90 68 50 55 50 63 10 M20 8 100 58 58 50 30

063 177.8 177.8 120 90 63 73 63 80 12 M30 8 125 75 75 62.5 38

080 250 145 110 80 88 80 100 16 M24 10 200

100 300 180 135 100 109 100 125 20 M30 10 245

T4
VALVE SIZE T1 T2 T3 When When T5 T6 T7 T8 T9 T10 T11 U W R1 R2
D4 min D4 max
±0.25 +0.1
016 43 56 11 34 29.5 20 15 2 2 0.5 10 18 0.03 0.05 0.8 2
+0.1 +0.1
025 58 72 12 44 40.5 30 20 2.5 2.5 1 10 24 0.03 0.05 0.8 3
±0.25 +0.1
032 70 85 13 52 48 30 27 2.5 2.5 1.5 10 32 0.03 0.1 0.8 3
±025 +0.1
040 87 105 15 64 59 30 32 3 3 2.5 10 36 0.05 0.1 1 5
+0.1 +0.1
050 100 122 17 72 65.5 35 32 4 3 2.5 10 36 0.05 0.1 1 5
±0.25 +0.1
063 130 155 20 95 86.5 40 47 4 4 3 10 52 0.05 0.2 1 5
+0.1 +0.1
080 175 205 25 130 120 40 40 5 5 4.5 10 45 0.05 0.2 2 8
+0.1 +0.1
100 210 245 29 155 142 50 48 5 5 4.5 10 53 0.05 0.2 2 8

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
ACCESSORIES – Spacers -

Spacers types: Spacer Spacer Spacer


Spacers for PE cartridges (K6) K6 K7 K8
Spacers for SE standard cartridges (K7)
Spacers for SE sealed cartridges (K8)

Spacers codes and seal kits:

K6 type. (PE cartridges)


LENGTH Seal kit code
Size 015 030 045 060 075 100 125 Perbunan Viton (Std)
016 3003159810 3003159820 3003159830 7702000552 7703000552
025 3003159910 3003159920 3003159930 7702000553 7703000553
032 3003160020 3003160030 7702000554 7703000554
040 3003160110 3003160120 3003160130 3003160140 7702000555 7703000555
050 3003156920 300315693 3003156940 3003156950 7702000556 7703000556
063 3003160220 3003160230 3003160240 3003160250 7702000557 7703000557
080 3003160320 3003160330 3003160340 3003160350 3003160360 3003160370 7702000558 7703000558
100 3003160420 3003160430 3003160440 3003160450 3003160460 3003160470 7702000559 7703000559

K7 type. (SE cartridges)


LENGTH Seal kit code
Perbunan
Size 015 030 045 060 075 100 125 Viton
(Std)
016 3003236510 3003236520 3003236530 7702000552 7703000552
025 3003236610 3003236620 3003236630 7702000553 7703000553
032 3003236710 3003236720 3003236730 3003236740 7702000554 7703000554
040 3003236810 3003236820 3003236830 3003236840 7702000555 7703000555
050 3003236910 3003236920 3003236930 3003236940 7702000556 7703000556
063 3003237020 3003237030 3003237040 3003237050 7702000557 7703000557
080 3003237120 3003237130 3003237140 3003237150 3003237160 3003237170 7702000558 7703000558
100 3003237220 3003237230 3003237240 3003237250 3003237260 3003237270 7702000559 7703000559

K8 type. (SE sealed cartridges)


LENGTH Seal kit code
Perbunan
Size 015 030 045 060 075 100 125 Viton
(Std)
016 3003231710 3003231720 3003231730 7702000552 7703000552
025 3003231810 3003231820 3003231830 7702000553 7703000553
032 3003231910 3003231920 3003231930 3003231940 7702000554 7703000554
040 3003232010 3003232020 3003232030 3003232040 7702000555 7703000555
050 3003232110 3003232120 3003232130 3003232140 7702000556 7703000556
063 3003232220 3003232230 3003232240 3003232250 7702000557 7703000557
080 3003232320 3003232330 3003232340 3003232350 3003232360 3003232370 7702000558 7703000558
100 3003232420 3003232430 3003232440 3003232450 3003232460 3003232470 7702000559 7703000559

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
8
ACCESSORIES – Seal kit -

SE/PE cartridges seal kit. SE sealed cartridges seal kit. PE sealed cartridges seal kit.
Seal kit code Seal kit code Seal kit code
Perbunan Perbunan Perbunan Perbunan Perbunan Perbunan
Size Size Size
(Std) (Std) (Std) (Std) (Std) (Std)
016 7702000228 7703000228 016 7702000562 7703000562 016 7702000570 7703000570

025 7702000229 7703000229 025 7702000563 7703000563 025 7702000571 7703000571

032 7702000230 7703000230 032 7702000564 7703000564 032 7702000572 7703000572

040 7702000231 7703000231 040 7702000565 7703000565 040 7702000573 7703000573

050 7702000232 7703000232 050 7702000566 7703000566 050 7702000574 7703000574

063 7702000233 7703000233 063 7702000567 7703000567 063 7702000575 7703000575

080 7702000234 7703000234 080 7702000568 7703000568 080 7702000576 7703000576

100 7702000235 7703000235 100 7702000569 7703000569 100 7702000577 7703000577

ACCESSORIES – Springs -

SE cartridges spring SE cartridges spring PE cartridges spring

Spring type Spring type Spring type


Size Ref. Code Size Ref. Code Size Ref. Code
1 247729 2862477290 1 247741 2862477410 016 4.56.31592 2850315920

016 2 247730 2862477300 050 2 247742 2862477420 025 4.56.31593 2850315930

3 247731 2862477310 3 247743 2862477430 032 4.56.31594 2850315940

1 247732 2862477320 1 247744 2862477440 040 4.56.31595 2850315940

025 050 4.56.30806 2850308060


2 247733 2862477330 063 2 247745 2862477450
063 4.56.31596 2850315960
3 247734 2862477340 3 247746 2862477460
080 4.56.30907 2850309070
1 247735 2862477350 1 247747 2862477470
100
032 2 247736 2862477360 080 2 247748 2862477480
3 247737 2862477370 3 247749 2862477490
1 247738 2862477380 1 247750 2862477500
040 2 247739 2862477390 100 2 247751 2862477510
3 247740 2862477400 3 247752 2862477520

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
9
STANDARD OPERATORS

A Plain operator

B Operator with stroke limiter

C Operator for use with pilot valve

Operator with stroke limiter for use with


D pilot valve

Operator with dual checks for use with pilot


E valve

Operator with dual checks and stroke


F limiter for use with pilot valve

Operator with pressure limiter


G (Sizes 016 thru 063)

Operator with pressure limiter for use with


H pilot valve
(Sizes 016 thru 063)

Operator for Sandwich pressure limiter for


K use with pilot valve
(Sizes 016 thru 063)

Operator with suttle check valve for use


L with pilot valve
(Sizes 016 thru 063)

Operator with pressure limiter for use with


M sealed pilot valve

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
10
ACCESSORIES – Seal kit -

Operator codes (Perbunan Seal)

016 025 032 040 050 063 080 100


S-A 5011011010 5012011010 5013011010 5014011010 5015011010 5016011010 5018011010 5019011010
S-B 5011021010 5012021010 5013021010 5014021010 5015021010 5016021010 5018021010 5019021010
01/02 5011031110 5012031110 5013031110 5014031110 5015031110 5016031110 5018031110 5019031110
S-C
03/04 5011031310 5012031310 5013031310 5014031310 5015031310 5016031310 5018031310 5019031310
01/02 5011041110 5012041110 5013041110 5014041110 5015041110 5016041110 5018041110 5019041110
S-D
03/04 5011041310 5012041310 5013011310 5014041310 5015041310 5016041310 5018041310 5019041310
01/02 5011051110 5012051110 5013051110 5014051110 5015051110 5016051110 5018051110 5019051110
S-E
03/04 5011051310 5012051310 5013051013 5014051310 5015051310 5016051310 5018051310 5019051310
01/02 5011061110 5012061110 5013061110 5014061110 5015061110 5016061110 5018061110 5019061110
S-F
03/04 5011061310 5012061310 5013061310 5014061310 5015061310 5016061310 5018061310 5019061310
01/02 5011071110 5012071110 5013071110 5014071110 5015071110 5016071110 - -
S-G
03/04 5011071310 5012071310 5013071310 5014071310 5015071310 5016071310 - -
01/02 5011081110 5012081110 5013081110 5014081110 5015081110 5016081110 - -
S-H
03/04 5011081310 5012081310 5013081310 5014081310 5015081310 5016081310 - -
S-K 5011091010 5012091010 5013091010 5014091010 5015091010 5016091010 - -
S-L 5011101010 5012101010 5013101010 5014101010 5015101010 - - -
07 - - 5013111111 - - - - -
S-M 20 - - 5013111112 - - - - -
35 - - 5013111113 - - - - -
50 - - 5013111114 - - - - -
07 5021071011 5022071011 5023071011 5024071011 5025071011 5026071011 5028071011 5029071011
20 5021071012 5022071012 5023071012 5024071012 5025071012 5026071012 5028071012 5029071012
P-G
35 5021071013 5022071013 5023071013 5024071013 5025071013 5026071013 5028071013 5029071013
50 5021071014 5022071014 5023071014 5024071014 5025071014 5026071014 5028071014 5029071014
07 5021081011 5022081011 5023081011 5024081011 5025081011 5026081011 5028081011 5029081011
20 5021081012 5022081012 5023081012 5024081012 5025081012 5026081012 5028081012 5029081012
P-H
35 5021081013 5022081013 5023081013 5024081013 5025081013 5026081013 5028081013 5029081013
50 5021081014 5022081014 5023081014 5024081014 5025081014 5026081014 5028081014 5029081014

Seal Kit Operator codes

016 025 032 040 050 063 080 100


P 7702000274 7702000283 7702000291 7702000300 7702000310 7702000320 - 7702000332
S-A
V 7703000274 7703000283 7703000291 7703000300 7703000310 7703000320 - 7703000332
P 7702000275 7702000284 7702000292 7702000301 7702000311 7702000321 - -
S-B
V 7703000275 7703000284 7703000292 7703000301 7703000311 7703000321 - -
P 7702000276 7702000285 7702000293 7702000302 7702000312 7702000322 7702000328 7702000333
S-C
V 7703000276 7703000285 7703000293 7703000302 7703000312 7703000322 7703000328 7703000333
P 7702000277 7702000286 7702000294 7702000303 7702000313 7702000323 - -
S-D
V 7703000277 7703000286 7703000294 7703000303 7703000313 7703000323 - -
P 7702000278 7702000287 7702000295 7702000304 7702000314 7702000324 7702000329 7702000334
S-E
V 7703000278 7703000287 7703000295 7703000304 7703000314 7703000324 7703000329 7703000334
P 7702000279 7702000288 7702000296 7702000305 7702000315 7702000325 - -
S-F
V 7703000279 7703000288 7703000296 7703000305 7703000315 7703000325 - -
P - - - - - - - -
S-G
V - - - - - - - -
P 7702000530 7702000514 7702000550 7702000544 - - - -
S-H
V 7703000530 - 7703000550 7703000544 - - - -
P - - - - - - - -
S-K
V - - - - - - - -
P - - 7702000526 7702000531 7702000527 - - -
S-L
V 7703000526 7703000531 - - - -
P - - - - - - - -
S-M
V - - - - - - - -
P - - - - - - - -
P-G
V - - - - - - - -
P - - - - - - - -
P-H
V - - - - - - - -

Bulletin 80.006-OTH-I
11 Rev.:1 February, 2008
HOW TO ORDER OPERATORS
Explanation

Example: S 050 - C X / 01 P /

Pressure
Omit = Without
pressure limiter
Operator Head
07 = 5 - 100 bar
S = Standard
20 = 5 – 200 bar
P = Relief valve function
35 = 5 - 350 bar
50 = 5 – 630 bar

Size
16, 25, 32, 40, 50, 63, 80, 100 Seals
P = Buna – N (std.)
V = Viton
Operator
A, B, C, D, E, F, G, H, K, L, M
Pilot Valve Mounting
(See page ?)
00 = No pilot valve
01 = Mounting surface (CETOP 03) available
for sizes 016 thru 050. Arranged for N.O.
Series pilot valve function
X (Last version will be delivered) 02 = Mounting surface (CETOP 05) available
for sizes 063 thru 100. Arranged for N.O.
pilot valve function
03 = Mounting surface (CETOP 03) available
for sizes 016 thru 050. Arranged for N.C.
pilot valve function
04 = Mounting surface (CETOP 05) available
for sizes 063 thru 100. Arranged for N.C.
pilot valve function

CETOP 03 CETOP 05

Ø
7 M6 23.8 23.8
T x10
20.6
10.5 10.5

10.3
A B
32.5
31

23

T T
16.25
15.5

9.5

46

B A
16.7

P
1.6

8.7 8.7
M5

P
x1

21.5
0

Ø
10

40.5 27
54

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
12
PLAIN OPERATOR-TYPE “A”

NOTE:
INSTALLING ORIFICE IN
PORT “W” WILL CONTROL
External pilot: CARTRIDGE PLUNGER
Can be used to connect area Aw to SHIFTING RATE.
one of the working ports (A or B).

GRAPHIC SYM BOL


OPERATOR HEAD
SHOWN

H2 M3
4 MOUNTING SCREWS

D 10
D5
D6

M1
B2

H3

M1/2
B2 /2

M5
D11

H1 PORT M ¼”G TEST


STATION FOR M1/2 M1
SIZES 040, 050,
PORT M ¼”G TEST AND 063 ONLY B 1/2
STATION FOR B1
SIZES 016, 025
AND 032 ONLY
Installation Dimensions for Type “A” Plain Operator Cartridge Insert
H1

°
45 PORT W “P1” NPT H2
8 MOUNTING
SCREWS
M/2
2 2 .5 °
D10

D5

D 11
W

D6
M

PORT M ¼”G TEST


STATION

H3
35°

Installation Dimensions for Type “A” Plain Operator for use with size 80 & 100 Cartridge Insert Valves.

VALVE SIZE B1 B2 D5 D6 D10 D11 H1 H2 H3 M1 M3 M5 M P1

016 MM 63.5 63.5 3,17 M8 9.5 3.17 30.0 13 6 46.0 25.0 10.5 1/16

025 MM 86 86 6.35 M12 13.3 4,75 30.0 17 5 58.0 33.0 16.0 1/16

032 MM 102 102 6.35 M16 16 4,75 35 20 5 70.0 41.0 17.0 1/16

040 MM 124.0 124.0 9.52 M20 19.1 4,75 50.0 30 5 85 50 23 1/16

050 MM 140 140 9.5 M20 19.1 6 50.0 25 5 100.0 58.0 30.0 1/8

063 MM 178 178 12.0 M30 21 6,35 60 37 5 125.0 75.0 38.0 1/8

080 MM 250,0 14,7 M24 30 7,9 80,0 25,5 8,6 200,0 3/8”

100 MM 300,0 17,9 M30 30 7,9 98,6 43,5 8,6 245,0 1/2”

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
13
OPERATOR W/STROKE LIMITER-TYPE “B”

And adjustment screw limits the travel of a NOTE:


floating pin which in turn limits the amount the INSTALLING ORIFICE IN
plunger can open. PORT “W” WILL
Thus, it results in (adjustable) throttling of flow CONTROL CARTRIDGE
through the insert valve. For fine adjustment, it PLUNGER SHIFTING
is suggested a cartridge plunger with a
cushion nose be used. GRAPHIC SYMBOL
It is suggested the adjustment screw be cut off OPERATOR HEAD SHOWN
at a length corresponding to minimum derived WITH INSERT VALVE.
flow to prevent accidentally locking the valve
in the closed position.

4 MOUNTING PORT M B1
¼”G TEST STATION
SCREWS M3 PORT W “P1” NPT
H2 M6
STROKE LIMITER
ADJUSTING SCREW
D6

D5

B2
M1
M1
D10

B2
2
D11

H3 H1 H4 MAXIMUM M5
M1
2
HH MINIMUM DISTANCE REQUIRED TO REMOVE
OPERATOR HEAD FROM MANIFOLD M1
BB1
Installation Dimensions for Type “B” Operator w/Stroke Limiter for use with size 016 through 063 Cartridge
Insert Valve
M6
PORT M ¼”G TEST STATION H2
PORT W “P1” NPT 8 MOUNTING
SCREWS
°
45

STROKE LIMITER
ADJUSTING SCREW
22.5°

D6
ØM
ØB
D5

D11
M
2

35°
MINIMUM DISTANCE HH H4 MAX. H1 H3
REQUIRED TO REMOVE
OPERATOR HEAD FROM
MANIFOLD

Installation Dimensions for Type “B” Operator w/Stroke Limiter for use with size 080 & 100 Cartridge Insert Valve.

VALVE
B B1 B2 D5 D6 D 10 D 11 H1 H2 H3 H4 M M1 M3 M5 M6 P1 HH BB1
SIZE

016 MM 69.9 63.5 3.96 M8 9.6 3.0 50.8 17.2 7.1 57.2 46 25 10.5 5 1/16” 36.6 38.1

025 MM 86 86 6.35 M12 13.3 4.8 51 16 8.6 74.7 58 33 16 9 1/16” 47.2 43

032 MM 102 102 6.35 M16 16.0 4.8 50 25 8.6 74.7 70 41 17 12 1/16” 57.2 51

040 MM 124 124 9.52 M20 19.1 4.8 54 26 8.6 114.3 85 50 23 15 1/16” 69 62

050 MM 140 140 9.5 M20 19.1 6.4 54 31 8.6 114.3 100 58 30 20 1/8” 78.2 70

063 MM 178 178 12.0 M30 21 6.4 75 38 8.6 114.3 125 75 38 29 1/8” 100 89

080 MM 250 14,7 M24 30 7,9 111,25 34,25 8,6 176,3 200 41,15 3/8” 139,7

100 MM 300 17,85 M30 30 7,9 136,5 47,5 8,6 226,1 245 50,8 1/2” 189,5

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
14
OPERATOR FOR PILOT VALVE-TYPE ”C”

These operator heads will T P GRAPHIC SYMBOL FOR SIZES T P


accommodate a plunger or ball 016 THRU 100. OPERATOR
HEAD SHOWN WITH INSERT
check type three-way valve. The VALVE AND OPTIONAL PILOT
drawings show commonly used B A
VALVE B A NOTE: PORT “X” MAY BE
M M CONNECTED TO EITHER
electrically operated valves. Thus, Y1 Y1
PORTS “A” OR “B” OR TO
with this operator, the cartridge valve SOME REMOTE POINT IN
Y X NOTE: Y X
functions as a pilot operated check THE SYSTEM
INSTALLING ORIFICES IN PORTS “A,
valve or appropriate area ratios. B, P AND T” WILL CONTROL
CARTRIDGE PLUNGER SHIFTING
RATE
N.O. PILOT VALVE FUNCTION N.C. PILOT VALVE FUNCTION

B1
2
M1 PORT Y1 (OPTIONAL) PILOT VALVE LOCATION
M1
2 M7 EXTERNAL DRAIN “P3” PLUG FOR SIZES 025, 032, 040,
SIZE FOR SIZES 025, 032, 040, 050 AND 063
D1 0 050 AND 063 H1 H3
D5
X

PORT M
¼”G TEST STATION
M3

FOR SIZE 016


S

W
M5

HEAD &
M1
2

D1 1
PORT P
H2
M1

4 MOUNTING
M3

M8
BB2

SCREWS

D6
H6
Y

M7 PORT M
PORT P
B1 ¼”G TEST STATION FOR
SIZES 025, 032, 040, 050
AND 063
NOTE:
PILOT VALVE
FOR DIMENSIONS OF OPTIONAL PILOT
LOCATION FOR
VALVES SEE MANUFACTURER´S CATALOG PORT Y1 (OPTIONAL) SIZE 016
EXTERNAL DRAIN “P3” PLUG
SIZE FOR SIZE 016
Installation Dimensions for Type “C” Operator for Pilot valve used with size 016 through 063. Cartridge Insert Valve

H3
D 11
35°

8 MOUNTING
SCREWS
NOTE:
B dia

FOR DIMENSIONS OF
M

OPTIONAL PILOT
30°
22.5°

VALVES SEE
D6

MANUFACTURER’S
M7
M

CATALOG
2

PORT Y2 TO BE PLUGGED
WHEN PORT Y1 IS USED
“P2” PLUG SIZE
45
°

PORT Y1 (OPTIONAL)
PORT M EXTERNAL DRAIN
D5 ¼”G TEST STATION H 1 H 2 “P3” PLUG SIZE

D 10

Installation Dimensions for Type “C” Operator for Pilot valve used with size 080 & 100 Cartridge Insert Valve

VALVE
B B1 B2 D5 D6 D10 D11 H1 H2 H3 H6 M M1 M3 M5 M7 M8 P3 BB2
SIZE
016 MM 63,5 88,9 3,17 M8 9,6 3,2 101,5 14 7,1 60,25 46 25 10,5 19,65 27 1/8”G 53,8

025 MM 86 86 4,77 M12 13,3 4,8 54 18 8,6 58 33 16 31,75 1/8”G 43

032 MM 102 102 6,35 M16 16,0 4,8 54 21 8,6 70 41 17 35 ¼”G 51

040 MM 124 124 8 M20 19,1 4,8 73 29 8,6 85 50 23 42,5 62

050 MM 140 140 8 M20 19,1 6,4 73 30 8,6 100 58 51 70

063 MM 178 178 11 M30 21,0 6,4 111 41 8,6 125 75 62,5 89

080 MM 250 14,7 M24 30 7,92 98,5 32 200 100 1/8”G

100 MM 300 14,7 M30 30 7,92 86 46 245 122,5 1/8”G

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
15
OPERATOR W/STROKE LIMITER FOR PILOT VALVES-TYPE ”D”

These heads include an adjustment screw


which limits the amount the plunger can NOTE:
T P INSTALLING ORIFICES IN T P
open as well as accommodate a plunger
PORTS “A, B, P AND T” WILL
or ball check type three-way valve. Thus, CONTROL CARTRIDGE GRAPHIC SYMBOL
the cartridge valve functions as a pilot B A PLUNGER SHIFTING RATE B A FOR SIZES 016 TRHU
operated check valve with a flow throttling M M 100. OPERATOR HEAD
Y1 Y1 SHOWN WITH INSERT
NOTE: PORT “X” MAY BE
adjustment. CONNEC TED TO EITHER VALVE AND OPTIONAL
It is suggested the adjustment screw be Y X PORTS “A” OR “B” OR TO Y X PILOT VALVE
cut off at a length corresponding to SOME REMOTE POINT IN THE
minimum desired flow to prevent SYSTEM
accidentally locking the valve in the
closed position. N.O. PILOT VALVE FUNCTION N.C. PILOT VALVE FUNCTION

PORT “Y1” (OPTIONAL)


EXTERNAL DRAIN “P3” PLUG SIZE
FOR SIZES 016 AND 025
NOTE:
FOR DIMENSIONS OF
OPTIONAL PILOT VALVES SEE
STROKE LIMITER
MANUFACTURERS CATALOG.
ADJUSTING
SCREW
PORT P

PORT “Y2” TO BE PLUGGED H2


WHEN PORT Y1 IS USED “P2”
PLUG SIZE. H6

M8
D6

BB2
4 MOUNTING M3 M W
PORT “Y1” (OPTIONAL)
Y1
SCREWS EXTERNAL DRAIN “P3” PLUG
B2

M1
M5
SIZE FOR SIZES 032, 040,

M 1/2
S
D 11

M3

X 050 AND 063

PORT “Y1” (OPTIONAL)


H3 H7 D5
EXTERNAL DRAIN “P3” PLUG SIZE PORT M ¼”NPT TEST
H1 H4 MAXIMUM D 10
FOR SIZES 0.32, 040, 050 AND 063 STATION
M /2
1
M 7

M1
HH MINIMUM DISTANCE REQUIRED B1/2
TO REMOVE OPERATOR HEAD FROM B1
MANIFOLD
Installation Dimensions for Type “D” Operator w/Stroke Limiter for Pilot Valves, used with Size 016 through 063 Cartridge Insert Valve

NOTE:
FOR DIMENSIONS OF OPTIONALS
H H3
PILOT VALVES SEE
22.5° 35°
MANUFACTURERS CATALOG. PORT “M” ¼” GAS TEST
PORT “Y1” (OPTIONAL) SCREW
EXTERNAL DRAIN “P3”
°
45

PLUG SIZE.
M6
D5

D 11

Y1
M7

X
ØM
ØB
D 10

Y W

M8
3

D6
M
2

8 MOUNTING
SCREW
MINIMUN DISTANCE REQUIRED TO REMOVE
OPERATOR HEAD FROM M ANIFOLD. HH H 4 MAX. H1 H2

Installation Dimensions for Type “D” Operator w/Stroke Limiter for Pilot Valves, used with Size 080 Cartridge Insert Valve

VALVE B B1 B2 D5 D6 D10 D11 H H1 H2 H3 H4 H6 M M1 M3 M5 M7 M8 P2 P3 HH BB2


SIZE

016 MM 63,5 89 3,17 M8 9,6 3,2 101,5 14 7,1 60,25 46 25 10,5 9,7 27 1/16” 1/8”G 36,6 53,8

025 MM 86 86 4,77 M12 13,3 4,8 114,3 18 8,6 60,25 58 33 16 25,5 12 1/8”G 47,2 43

032 MM 102 102 6,35 M16 16 4,8 111,3 19 8,6 60,25 70 41 17 15,75 ¼”G 57,2 51

040 MM 124 124 8 M20 19,1 4,8 111,3 26 8,6 60,25 85 50 23 20,5 ¼”G 69,0 62

050 MM 140 140 8 M20 19,1 6,4 111,3 30 8,6 60,25 100 58 30 25,5 ¼”G 78,2 70

063 MM 178 178 11 M30 21 6,4 159 42 8,6 84,25 125 75 38 30,25 ¼” 3/8”G 100 89

080 MM 250 14,7 M24 30,2 7,9 39.9 142 40 8,6 176,3 200 19,1 58,7 139,7

H1 -
100 MM 300 14,7 M30 30,2 7,9 136,7 48 8,6 226,1 245 19,1 76,2 189,5
84.15

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
16
OPERATOR W/DUAL CHECK FOR PILOT VALVES-TYPE ”E”

GRAPHIC SYM BOL FOR SIZES 016


This operator head will T P TRHU 100. OPERATOR HEAD T P
accommodate a plunger or ball SHOWN WITH INSERT VALVE AND
NOTE: PORT “X” AND
check type three-way pilot valve OPTIONAL PILOT VALVE
B A “Z1” MAY BE
B A
which can connect through two M M CONNECTED TO
Y1 Y1 EITHER PORTS “A” OR
integral check valves to ports X and NOTE: “B” OR TO SOME
Z. With this operator, the cartridge Y X Z1 INSTALLING ORIFICES IN Y X Z1 REMOTE POINT IN
insert valve functions as a two-way PORTS “A, B, P AND T” WILL THE SYSTEM
CONTROL CARTRIDGE
valve. PLUNGER SHIFTING RA TE

N.O. PILOT VALVE FUNCTION N.C. PILOT VALVE FUNCTION

NOTE: B1 PILOT VALVE


2
FOR DIMENSIONS OF OPTIONAL PILOT M 1 PORT “Y1” (OPTIONAL) LOCATION FOR
VALVES SEE MANUFACTURERS CATALOG. M1 EXTERNAL DRAIN “P3” SIZES 025, 032, 040,
2 M7 PLUG SIZE FOR SIZES H1 H3 050 AND 063
016, 032 AND 063 PORT M
X

PORT “Y1” (OPTIONAL) ¼”G TEST STATION


FOR SIZE 016
D5

EXTERNAL DRAIN “P3” PLUG SIZE


M3

FOR SIZES 025 040 AND 050


S

4 MOUNTING
M5
M1

D10

HEAD &
B2

SCREWS

D11
PORT P
H
Z1

2
M1

PORT M ¼”G TEST


2
M3

M8
BB2

STATION FOR SIZES 025,

D6
H 6
032, 040, 050 AND 063
Y

M7

PORT P
PORT M ¼”NPT TEST
B1
STATION FOR SIZE 016
NOTE:
FOR DIMENSIONS OF OPTIONAL PILOT VALVE LOCALITATION
PILOT VALVES SEE FOR SIZE 016
MANUFACTURER´S CATALOG
Installation Dimensions for Type “E” Dual Check Operator for Pilot Valve used with size 016 through 063. Cartridge Insert Valves

H3

D1 1
8 MOUNTING
SCREWS
35°

NOTE:
FOR DIMENSIONS OF OPTIONAL
B dia

PORT Y2 TO BE PLUGGED
M

PILOT VALVES SEE


WHEN PORT Y1 IS USED
30°

MANUFACTURER’S CATALOG
22.5°

“P2” PLUG SIZE


D6
M7
M
2

PORT Y1 (OPTIONAL)
EXTERNAL DRAIN “P3”
45
°

PLUG SIZE

PORT M
D5 H1 H2
¼”G TEST STATION

D 10

Installation Dimensions for Type “E”Dual Check Operator for Pilot valve used with size 080 & 100 Cartridge Insert Valve
VALVE
B B1 B2 D5 D6 D10 D11 H1 H2 H3 H6 M M1 M2 M3 M5 M7 M8 P3 BB2
SIZE
016 MM 63,5 101,6 3,2 M8 9,5 3,2 101,6 15 7,1 60,5 46 25 25 10,5 9,7 26,9 1/8”G 53,8

025 MM 85,8 85,8 4,8 M12 12,7 4,8 53,8 20 8,6 58 33 33 16 31,8 1/8”G 42,9

032 MM 101,6 101,6 6,35 M16 16 4,8 54 21 8,6 70 41 41 17 35,1 ¼”G 50,8

040 MM 124 124 8 M20 19,1 4,8 73 29 8,6 85 50 50 23 44,5 62

050 MM 139,7 139,7 8 M20 19,1 6,4 73 30 8,6 100 58 58 30 50,8 69,9

063 MM 177,8 177,8 11 M30 21 6,4 111 45 8,6 125 75 75 38 63,5 88,9

080 MM 250 14,7 M24 30,2 7,9 98,6 40 8,6 200 100

100 MM 300 14,7 M30 30,2 7,9 98,6 45 8,6 245 122,5

Bulletin 80.006-OTH-I
17 Rev.:0 July, 2007
OPERATOR W/DUAL CHECK & STROKE LIMITER FOR PILOT VALVES-TYPE ”F”
GRAPHIC SYMBOL FOR SIZES
These heads include an adjustment screw
016 TRHU 100 . OPERATOR HEAD
(which limits the amount the plunger can T P SHOWN WITH INSERT VALVE T P
open), and will accommodate a plunger or AND OPTIONAL PILOT VALVE
ball check type three-way pilot valve which
can connect through the two integral check B A NOTE: B A
valves to ports X and Z. With this operator, M INSTALLING ORIFICES IN M
the cartridge insert valve functions as an Y1 PORTS “A, B, P AND T” WILL Y1
area ratio two way valve with throttling CONTROL CARTRIDGE
adjustment. Y X Z1 PLUNGER SHIFTING RATE Y X Z1
It is suggested the adjustment screw be cut
NOTE: PORT “X” AND “Z1”
off at length corresponding to minimum MAY BE CONNECTED TO
desired flow to prevent accidentally locking EITHER PORTS “A” OR “B”
the valve in the closed position. OR TO SOME REMOTE POINT
N.O. PILOT VALVE FUNCTION IN THE SYSTEM N.C. PILOT VALVE FUNCTION

PORT “Y1” (OPTIONAL)


EXTERNAL DRAIN “P3”
NOTE: PLUG SIZE FOR SIZES 032,
FOR DIMENSIONS OF OPTIONAL PILOT 040, 050 AND 063.
PORT “Y1” (OPTIONAL)
VALVES SEE MANUFACTURERS CATALOG.
EXTERNAL DRAIN “P3” PLUG SIZE
FOR SIZES016 AND 025
PORT P

H2 PORT M
4 MOUNTING ¼”G TEST STATION
SCREWS
H6

M8
D6

BB2
M3

M1
B2

M5
M 1/2
D1 1

M3

PORT Y2 TO BE STROKE LIMITER


PLUGGED WHEN ADJUSTING
PORT Y1 IS USED “P2” SCREW
PLUG SIZE
H3 H7 D5
H1 H 4 MAXIMUM D 10
M 1/2 M7
HH MINIMUM DISTANCE REQUIRED TO
REMOVE OPERATOR HEAD FROM MANIFOLD M1
B1/2
B1
Installation Dimensions for Type “F” Dual Check Operator with Stroke Limiter for Pilot Valve used with 016 trough 063 Cartridge Insert Valve

H H3
22.5° 35° PORT Y1
PORT Y2 TO BE PLUGGED (OPTIONAL)
WHEN PORT Y1 IS USED EXTERNAL
°

“P2” PLUG SIZE


45

DRAIN “P3”
PLUG SIZE
Z1
M6 STROKE LIMITER 8 MOUNTING
ADJUSTING SCREW
D5

D11

Y1 SCREWS
M7

X
ØM
ØB
D10

Y W
3

M8
D 6
M

NOTE:
2

FOR DIMENSIONS OF
OPTIONAL PILOT
VALVES SEE
MANUFACTURER’S
CATALOG
MINIMUM DISTANCE REQUIRED TO REMOVE
OPERARATOR HEAD FROM MANIFOLD HH H4 MAX. H1 H2

Installation Dimensions for Type “F”Dual Check Operator with Stroke Limiter for Pilot Valve used with Size 080 & 100 Cartridge Insert Valves
VALVE
B B1 B2 D5 D6 D 10 D 11 H H1 H2 H3 H4 H6 H7 M M1 M2 M3 M5 M7 M8 P3 HH BB2
SIZE

016 MM 63,5 101,6 3,2 M8 9,5 3,2 101,6 15 7,1 57,2 60,5 46 25 25 10,5 9,7 26,9 1/8”G 36,6 53,8

025 MM 85,8 85,8 4,8 M12 12,7 4,8 114,3 20 8,6 74,7 60,5 58 33 33 16 31,8 14,2 1/8”G 47,2 42,9

032 MM 101,6 101,6 6,4 M16 16 4,8 111,3 21 8,6 74,7 60,5 31,8 70 41 41 17 35,1 ¼”G 57,2 50,8

040 MM 124 124 7,9 M20 19,1 4,8 111,3 29 8,6 114,3 60,5 47,8 85 50 50 23 44,5 69 62,0

050 MM 139,7 139,7 7,9 M20 19,1 6,4 111,3 30 8,6 114,3 60,5 47,8 100 58 58 30 50,8 78,2 69,9

063 MM 177,8 177,8 11,1 M30 20,6 6,4 158,8 45 8,6 176,3 84,1 60,5 125 75 75 38 63,5 100 88,9

080 MM 250 14,7 M24 30,2 7,9 39.9 136,7 40 8,6 176,3 200 19,1 58,7 139,7

H1 –
100 MM 300 14,7 M30 30,2 7,9 136,7 45 8,6 226,1 245 19,1 76,2 189,5
84.15

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
18
OPERATOR W/PRESSURE LIMITER-TYPE “S _ G”

GRAPHIC SYMBOL
OPERATOR HEAD SHOWN
WITH INSERT VALVE.

B1
B1
2 PORT W “P1” NPT
4 MOUNTING H2
SCREWS

D6
B2
2

D5
M3

M1
2

M1
B2

M5

W
M3

D10

D11
X

M1
2 H 4 max H1 H3

M1

Installation Dimensions for Type “G” Operator w/Pressu re Limiter for use with size 016 through 063 Cartridge Insert Valve

VALVE
B1 B2 D5 D6 D10 D11 H1 H2 H3 H4 M1 M3 M5 P1
SIZE
016 MM 64 64 4 M8 9.6 3 50 14 6 59 46 25 10.5 1/16”

025 MM 86 86 4 M12 13.3 5 50 18 5 59 58 33 16 1/16”

032 MM 102 102 6 M16 16 5 50 22 5 59 70 41 17 1/16”

040 MM 124 124 8 M20 19.1 5 85 27 5 73 85 50 23 1/8”

050 MM 140 140 8 M20 19.1 6 90 25 5 73 100 58 30 1/8”

063 MM 178 178 8 M30 21 6 90 73 125 75 38 1/8”

Bulletin 80.006-OTH-I
Rev.:1 May, 2008
19
OPERATOR W/PRESSURE LIMITER FOR PILOT VALVE-TYPE “S _ H”

GRAPHIC SYMBOL
OPERATOR HEAD
SHOWN WITH INSERT
VALVE.
57

H2

D5

D6
Y
M3
M1
2

W
M1
B1

M5
M3

1
BB

D1 1
X

D10

M1
2 79 H1 H3
M1
B2
2

B2

Installation Dimensions for Type “H” Operator w/Pressure Li miter for use w/pilot valve with size 016 through 063 Cartridge Insert Valve

VALVE
B1 B2 BB1 D5 D6 D10 D11 H1 H2 H3 M1 M3 M5 P1
SIZE

016 MM 81 64 43 3 M8 9.6 3.17 50 14 7 46 25 10.5 1/16”

025 MM 86 86 43 5 M12 13.3 4.75 55 19 58 33 16 1/16”

032 MM 102 102 51 5 M16 16 4.75 55 23 5 70 41 17 1/16”

040 MM 124 124 62 8 M20 19.1 4.75 65 27 5 85 50 23 1/16”

050 MM 140 140 70 8 M20 19.1 6.5 65 100 58 30 1/16”

063 MM 178 178 89 10 M30 21 6.5 70 125 75 38 1/16”

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
20
SANWICH PRESSURE LIMITER-TYPE “K”

GRAPHIC SYMBOL
OPERATOR HEAD
SHOWN WITH INSERT
VALVE.

D10
H2
D5

D6
M1
2
B1

M1

M5
1
BB

D11

M1
2 H1 H3

M1
B2
2

B2

Installation Dimensions for Type “K” Operator for sandwich pressure limiter with size 016 through 063 Cartridge Insert Valve

VALVE
B1 B2 BB1 D5 D6 D10 D11 H1 H2 H3 M1 M3 M5
SIZE

016 MM 85 63,5 35,1 4 M8 9.6 3 55 12 4 46 25 10.5

025 MM 86 86 43 5 M12 13.3 4.75 50 17 58 33 16

032 MM 102 102 51 5 M16 16 4.75 50 24 5 70 41 17

040 MM 124 124 62 8 M20 19.1 4.75 50 29 5 85 50 23

050 MM 140 140 70 8 M20 19.1 6.5 50 29 100 58 30

063 MM 178 178 89 8 M30 21 6 60 44 125 75 38

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
21
OPERATOR W/SHUTTLE CHECK VALVE -TYPE “L”

GRAPHIC SYMBOL
OPERATOR HEAD SHOWN
WITH INSERT VALVE.

PILOT VALVE LOCATION FOR


SIZES 016.

PILOT VALVE LOCATION FOR


SIZES 025, 032, 040, 050 AND 063.

D11
H2 D5
D6

B1

M3

M6
M1
D11

M5
M1

M3
2

BB 1

M1
H3 H1 2

M1
B2

Installation Dimensions for Type “L” Operator with shuttle check valve with size 016 trough 050 Cartridge Insert Valve.

VALVE
B1 B2 BB1 D5 D6 D10 D11 H1 H2 H3 M1 M3 M5 M6
SIZE
016 MM 89 63,5 35,2 3.17 M8 9.6 3 100 12 6 46 25 10.5

025 MM 130 87 43,5 6.35 M12 13.3 5 85 20 5 58 33 16 8.7

032 MM 120 102 51 5 M16 16 6 85 23 5 70 41 50.8 10.8

040 MM 125 125 62.5 6.15 M20 19.1 5 85 29 4 85 50 23 17.5

050 MM 140 140 70 6 M20 19.1 6 85 27 4 100 58 30 20

Bulletin 80.006-OTH-I
Rev.:0 July, 2007
22
OPERATOR W/PRESSURE LIMITER SEALED PILOT VALVE -TYPE “M”

GRAPHIC SYMBOL
OPERATOR HEAD SHOWN
WITH INSERT VALVE.

PILOT VALVE LOCATION FOR


SIZES 032.
D10
D5

Y
M3

Z1
W
H1

B1
M1

M5
Z2
M1

BB 1
M3
2
H2

X
H3

D6 D11 M1
2

M1

Installation Dimensions for Type “M” Operator with shuttle check valve with size 032 Cartridge Insert Valve.

VALVE
B1 B2 BB1 D5 D6 D10 D11 H1 H2 H3 M1 M3 M5
SIZE
032 MM 102 102 51 5 M16 16 5 70 23 5 70 41 17

Bulletin 80.006-OTH-I
23 Rev.:0 July, 2007