0% found this document useful (0 votes)
556 views1 page

Level Transmitter - DP Type

This document provides specifications for a level transmitter that will measure and indicate the level in a product water tank for a 5 MIGD mobile sea water desalination plant. The level transmitter uses differential pressure technology and will have a measurement range of 0-4000 mmWC with an output of 4-20 mA DC. It must be IP65 rated and have local digital display in engineering units.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
556 views1 page

Level Transmitter - DP Type

This document provides specifications for a level transmitter that will measure and indicate the level in a product water tank for a 5 MIGD mobile sea water desalination plant. The level transmitter uses differential pressure technology and will have a measurement range of 0-4000 mmWC with an output of 4-20 mA DC. It must be IP65 rated and have local digital display in engineering units.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ILF Consulting Engineer SHEET NO.

: 2 OF 5
Al Majan House, LEVEL TRANSMITTER JOB NO.: 925
1st. floor, Al Khuwair ( DP TYPE ) SPEC NO.: A4-C925-ID-02-006
OMAN

CLIENT : SEPTECH MUSCAT LLC Sl.NO BY CHKD APPRD DATE REV

CONSULTANT : ILF Consulting Engineer - OMAN 1 SS KRR CS 25.11.09 0

PLANT: 5 MIGD MOBILE SEA WATER DESALINATION 2 SS KRR CS 22.12.09 A


PLANT 3 SS KRR CS 31.12.09 B
1 Tag No. 925-LIT-41 A
GENERAL

2 Function Level Measurement & Indication in Product Water Tank (T- 41)
3 Area Classification Safe Area
4 Tank Height / Material 4 Mtrs / GRP
5 Tank Open / Close Type Closed
6 Service Product Water tank
Product water
PROCESS

7 Fluid
8 Max. Pressure/Normal Pressure 5 / 1.5 Kg/cm2 g
10 Max. Temperature 65°C
11 Specific Gravity 1.0
12 Type Differential Pressure Type
13 OutPut 2 Wire, 4 ~ 20 m A DC,
14 Scale Linear in MM
15 Enclosure Class WP to IP65
16 Power Supply 24 V DC,600 Ohms
17 Housing Low copper Cast-Aluminium alloy with polyurethane paint
XMTR

18 Calibration Range 0 - 4000 mmWC


19 Transmitter Range *
20 Mounting 2" Pipe Mount
21 Accuracy ± 0 . 25 % of URV
22 Cable Entry 1/2" NPT (F)
23 Local Display Digital , LCD in Engg. Units
24 Element Type Flush Diaphragm
25 Element Material SS 316
26 Body Material SS 316
UNIT

27 Differential Range Adjustable


28 Process Connection(LP) 1/2 " NPT ( F )
29 Process Connection(HP) 1/2 " NPT ( F )
30 Process Connection Location Side-Side
OPTIONS

31 3 Way Manifold Required

32 Mounting Bracket 2" Pipe Mount

33 Manufacturer *
34 Model No. *
Notes : * - Vendor to Specify

1. Instrument shall be calibrated in MM WC to show Level in mm corresponding to 0 ~ 4000 mm in Tank