REVISION NO.

0
ISSUED FOR ENQUIRY
AKER KVAERNER POWERGAS PREPD.BY/DATE DVG26/10/05
CHKD. BY/DATE CKS27/10/05
APPD. BY/ DATE SGS27/10/05

INSTRUMENT DATA SHEET


PRESSURE TRANSMITTER 0
REV. PREPD. CHKD. APPD. DATE

PROJECT INDIA GFL CMS PROJECT MASS FLOWMETER


ITEM CMS UNITS DWG.NO. 05028-47-P-201
STAGE BED sheet 1 of 1
1 TAG NO. FT-2316 FT-2319
2 P & ID NO. 1308-7001-L307 1308-7001-L308
3 SERVICE 100-AB3-MCL-3044 100-AB3-CF-3061
GENERAL 4 LINE NUMBER CH2CL2 Product CHCL3 Product
5 LINE SIZE / SCHED. DN100 /SCH.STD DN100 /SCH.STD
6 LINE MATERIAL ASTMA106 Gr.B ASTMA106 Gr.B
7
8 FLUID / STATUS CH2CL2/L CHCL3/L
9 MAX. FLOW (m3/h) 42 42
OPERATE 10 NOR. FLOW MIN. FLOW 35 14 35 14
CONDI- 11 OPER. PRESSURE (Kg/cm2G) 5.12 4.4
TION 12 OPER. TEMPERATUR (℃) 40 40
13 DENSITY AT OPER. (kg/m3) 1300 1450
14 VISCOSITY AT OPER. (cP) 0.39 0.49
15 CONDUCTIVITY (S/cm)
16 Design Press / Temp. 13 Kg/cm2g / 150 0C 13 Kg/cm2g / 150 0C
17 MODEL NO. * *
18 TYPE Coriolis Coriolis
19 RANGE 0 ~ 60 m3/h 0 ~ 60 m3/h
20 ACCURACY ±0.1% ±0.1%
21 SIZE * *
22 CONNECTION TYPE / RATING ANSI 150# RF ANSI 150# RF
23 BODY MATERIAL 316SS 316SS
METER 24 WETTED PART MATERIAL 316L 316L
25 TRANSMITTER OUTPUT 4~20 mA+HART 4~20 mA+HART
26 TRANS. ENCLOSURE CLASS Ex d II CT4 Ex d II CT4
27 PROTECTION CLASS IP67 IP67
28 ELEC. CONN. SIZE 1/2"NPTF 1/2"NPTF
29 POWER SUPPLY 110V AC, 50Hz 110V AC, 50Hz
30 Diff. Pressure * (Mimimum ) * (Mimimum )
31 Transmitter Integral to Sensor Integral to Sensor
32 No of cable entries * *
33
34
35
36
37
38 LOCAL INDICATON LCD display LCD display
39 Signal Cable / Length * *
ACCE- 40
SSORIES 41
42
43
44
45
46
47 IBR - -
48 Radiograpghy Test Required Required
49 MANUFACTURER Ref. Annexure "A" Ref. Annexure "A"
50 MODEL NO. Ref. Annexure "A" Ref. Annexure "A"

NOTES (1) ACTUAL CONNECTION SIZE OF FLOW METER WILL BE DETERMINED THROUGH THE VENDOR SELECTION , LATER.
(2) INSTRUMENT WITH THE HIGHEST PERFORMANCE AND ACCURACY SHOULD BE SELECTED.
(3) " * " : Vendor to advise
(4) Vendor to quote optionally Weights & Measures certifice Mass Flow Meters

Note: This sheet is the copyright of Hualu Engineering & technology Co., Ltd. and may not be copied in whole or in part without the writen consent of Hualu. This sheet and all copies must be
returned on demand.
SPECIFICATION NUMBER
MASS FLOWMETER
1308 / C / 14I051010
Aker Kvaerner Powergas DATA SHEET

CLIENT: GUJARAT FLUROCHEMICAL LTD.. SHEET: 1 of 1


Item Number 1 2 3 1
Tag Number FT-2801 FT-2802 FT-2803 2
P & ID Number 1308-7001-L801-R1 1308-7001-L802-R1 1308-7001-L802-R1 3
Service CH2CL2 Tanker Loadout CHCL3 Tanker Loadout CCL4 Tanker Loadout 4
GENERAL

Line Number 80-AB3-MCL-80110 80-AB3-CT-80206 80-AB3-CT-80214 5


Line Size / Material 80 NB / - 80 NB / - 80 NB / - 6
Quantity ONE ONE ONE 7
Manufacturer * * * 8
Type of Flowmeter Coriolis Mass Coriolis Mass Coriolis Mass 9
10
Model Number * * * 11
Size * * * 12
Rating ANSI 150# ANSI 150# ANSI 150# 13
SENSOR

Tube & Wetted Parts Material 316L 316L 316L 14


Sensor Housing SS 316 SS 316 SS 316 15
Power Supply * * * 16
Electrical Class Safe Safe Safe 17
End Connections */Flanged, ANSI 150# RF */Flanged, ANSI 150# RF */Flanged, ANSI 150# RF 18
19
S

Model Number * * * 20
Power Supply 110 V AC 110 V AC 110 V AC 21
Electrical Class Safe Safe Safe 22
TRANSMITTER

Location Integral Integral Integral 23


Flow Rate Output 4-20mA +HART 4-20mA +HART 4-20mA +HART 24
Density Output 25
Transmitter Enclosure Class Weatherproof, IP67 Weatherproof, IP67 Weatherproof, IP67 26
Electrical Connection Size 1/2" NPT(F) 1/2" NPT(F) 1/2" NPT(F) 27
No. of Cable Entries * * * 28
29
Fluid CH2CL2 / Liq. CHCL3 / Liq. CCl4 / Liq. 30
Flow Units m3/hr m3/hr m3/hr 31
Flow : Nor / Max 20 / - 20 / - 20 / - 32
Flow Range 0-40 m3/hr 0-40 m3/hr 0-40 m3/hr 33
Oper. Press (Kg/cm2g) 3.7 3.4 3.5 34
Max. Press (Kg/cm2g) 5 5.4 5.6 35
SERV. COND.

Temp : Nor / Max 40 / -- 40 / -- 40 / -- 36


Density Operating (Kg/m3) 1290 1450 1557 37
Density Range (Kg/m3) --- --- --- 38
Electrical Class Safe Safe Safe 39
Viscosity cP 0.4 0.49 0.78 40
Design Press / Temp * * * 41
Accuracy + 0.1% + 0.1% + 0.1% 42
P Allowable 0.5 Kg/cm2 (Max.) 0.5 Kg/cm2 (Max.) 0.5 Kg/cm2 (Max.) 43
44
Local Indication LCD Display LCD Display LCD Display 45
Signal Cable/Length NOTE - 3 NOTE - 3 NOTE - 3 46
SP. OPTIONS

Auxiliary Output 47
48
49
50
51
52
C935042 R3

1] Instrument with the Highest performance and Accuracy should be selected. 53


REMARKS

2] " * '' Vendor to advise 54


3] Consider 10 mtr. Length in case of Remote type mass flow meter. 55
56
57
REVISION NO. 0
ISSUED FOR ENQUIRY
PREPD. BY/DATE DVG 04/01/06
CHKD. BY/DATE CKS 05/01/06
APPD. BY/DATE SGS 06/01/06