Components
Components
FROM TOLUENE
Submitted by
M.SRIRAM
810016239041
PETROCHEMICAL TECHNOLOGY
6.ENERGY BALANCE
6.1THE MIXER
Inlet temperature=15⁰C
Outlet temperature=30⁰C
Reference temperature=25⁰C
Total input=156236.5
Heat leaving the
mixer
Reference temperature=25⁰C
Inlet temperature=30⁰C
Outlet temperature=35⁰C
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Toluene 1000 1.13 15 11300
Mixed acid 14309 1.9256 30 137767.052
Total input=149067.052
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Nitrated product 15309 1.425 35 218153.25
Total output=218,153.25
6.3COOLER
Inlet temperature=50⁰C
Outlet temperature=20⁰C
Reference temperature=25⁰C
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Spent acid 10820 1.9256 50 416699.84
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Cycle acid 10820 1.9256 20 104174.96
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Washed 1451 1.8 15 26118
Mononitrotoluene
6.5 DISTILLATION COLUMN
Inlet temperature=15⁰c
Outlet temperature=92⁰c
Reference temperature=25⁰c
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Washed 1451 1.8 15 26118
Mononitrotoluene
Steam 40psi 510 1.9 130 101745
Total input=127863
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 1367 1.8 92 164.8602
Mononitrotoluene 0.058 1.8 120 9.918
Residue
Fore runnings 0.027 1.8 15 0.486
Steam 510 1.9 130 101745
Total output=101920.264
6.6 CONDENSER
The vapour rising to the condenser amounts is
=1367/137
=9.97kgmol/h
The latent heat λv=49825.3kJ/kgmol
Therefore condenser loading = m*λv
=9.97*49825.3
=497161.935kJ/h
The water is used @ 18⁰C and 30⁰C
=497161.935/(30-18)*4.187
=7915kg/h
Inlet temperature=18⁰C
Outlet temperature=30⁰C
Reference temperature=25⁰C
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 1367 1.8 92 164.8602
Vapour
Cooling water 7915 4.187 18 237980.735
Total input=238145.595
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 1367 1.8 92 164.8602
Liquid
Cooling water 7915 4.187 30 331401.05
Total output=331565.915
6.7 RESIDUE COOLER
Inlet temperature=120⁰c
Outlet temperature=40⁰c
Reference temperature=25⁰C
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 58 1.8 120 9918
Residue
Cooling water 7915 4.187 15 331401.05
Total input=341319.05
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 58 1.8 40 1566
Residue
Cooling water 7915 4.187 20 165700.525
Total output=167266.525
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 1367 1.8 92 164860
Feed
Steam 90psi 83.58 1.9 180 24614
Total input=189474
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Hot 1367 1.8 133 265744.8
Mononitrotoluene
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Cool 803 1.8 133 14454
Mononitrotoluene
6.8.4 REBOILER
INPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 483 1.8 133 93895
feed
OUTPUT
Component Flow rate Specific heat Temp Heat (Q)
Kg/h capacity (cp) ⁰C kJ/h
KJ/KgK
Mononitrotoluene 4498 1.8 117 744868
vapour
DESIGN OF EQUIPMENTS
DESIGN OF REACTOR
Volume of the reactor is calculated using volumetric flow rate and residence time.
Diameter of the reactor is found from V= π r 2L
Diameter of the agitator Da and baffle width are calculated from the diameter of the
reactor.
Length and height of the blade are found using agitator diameter.
Diameter of the hub is calculated using the relation Dh=Da-2L
Diameter of the shaft is calculated from the diameter of the hub.
The shaft power required to drive an agitator is found using the relation
PA=NP*row*N3*Da5
Thickness of the cylindrical part is determined using the formula t=pD/2fj+ C
Design Calculation
Residence time τ= 2h
Volumetric flow rate v0 = (1000/867)+(14309/1670)
= 1.153+8.568
v0 = 9,72 m3/h of feed
Volume of the feed V= v0*τ
= 2*9.72
V = 19.44 m3
Let us assume that the reactor contains 80% liquid
Actual Volume of the Reactor = 19.44/0.8
V= 24.3 m3 of the Reactor
Design of Agitator:
Diameter of reactor D = 1.28 m
Diameter of agitator Da = D/3
Da = 0.426
Baffle Width:
J = D/12
J = 1.28/12
J= 0.106 m
Length of the Blade:
L=Da/4
L= 0.1065 m
Height of the Blade:
W= Da/5
W=0.426/5
W= 0.0852m
Height of the liquid:
Height of the liquid= H=D= 1.28m
Diameter of the Hub:
Dh= Da – 2L
Dh= 0.426 - 2*(0.1065)
Dh = 0.213m
Diameter of the Shaft:
Ds=Dh/2
Ds= 0.213/2
Ds= 0.1065
Calculation of the cylindrical part:
Thickness t = (p D / 2 f j) + C
t =(1454/2295)+2
t = 2.63mm
Design Summary:
DESIGN OF CONDENSER
= 0.379 kg/s
7
Latent heat of vaporization of MNT, λv,MNT = 4.6 x 10 J/kmol.
= 335.766 kJ/kg
HEAT BALANCE
Qw = QMNT
mw * Cpw (∆T)w = mMNT * λMNT
mw = 0.379 x 335.766 x103
=1.45kg/s
Q = (m * λ)MNT
3
= 0.379 x 335.766 x 10
= 95827.73 W
LMTD CALCULATIONS
Therefore, Tm = FT LMTD
= 0.29 * 68.14
= 19.78 °C
ROUTING OF FLUIDS
SHELL ID
Shell ID = Lb + Cs
Nt= C{(Lb/Pt)2}
48= 0.86(Lb/0.025)2
Lb= 0.18677 = 186.77 mm
Cs = 93mm
Shell ID = 279.77 mm
TUBE PASSES
(π/4)(Di)2*(Nt/Np)*(v)= ⱱ
(π/4)*(0.0125)2*(48/Nt)*(1.5)= 1.45/1000
Number of passes = Np = 2
Therefore
2
A corrected = 48 x 0.0887 = 4.2576 m
TUBE SIDE
3
Density = ρ t = 995.026 kg/m
hi di / кt = 0.023 (Re)0.8(Pr)0.33(µ/µw)0.33
0.8 0.4
hi = (0.614/0.012573) x 0.023 x (7114.9) (5.83)
hio=(3469.04)(0..0158)
-3
= 3.3 x 10 m
DESIGN SUMMARY