9580V User & Reference Guide
9580V User & Reference Guide
Export of technical data contained in this document may require an export license from the
United States government and/or the government of Japan. Contact the Hitachi Data
Systems Legal Department for any export compliance questions.
Referenced Documents
Hitachi Freedom Storage™ Thunder 9500™ V Series FlashAccess 9500V User’s Guide,
MK-92DF612
Hitachi Freedom Storage™ Thunder 9500™ and 9200™ V Series Resource Manager User’s
Guide Graphical User Interface (GUI), MK-92DF605
Hitachi Freedom Storage ™ Thunder 9500 ™ and 9200™ V Series Resource Manager User’s
Guide Command Line Interface (CLI), MK-92DF603
Hitachi Freedom Storage™ Thunder 9500™ V Series ShadowImage 9500V User’s Guide,
MK-92DF607
Hitachi Freedom Storage™ Thunder 9500™ V Series Synchronous TrueCopy 9500V User’s
Guide, MK-92DF608
Hitachi Freedom Storage™ Thunder 9500™ V Series 19-Inch Rack Reference Guide,
MK-92DF654
Hitachi Data Systems Global 19-Inch Rack Reference Guide, MK-92DF665
iv Preface
Preface
The Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide describes
the physical, functional, and operational characteristics of the 9580V subsystem. This
document also provides operation instructions, installation details, and configuration
planning information for the 9580V subsystem.
The user is familiar with the Hitachi Freedom Storage™ Thunder 9580™ V Series array
subsystem.
The user is familiar with the Windows® 98, Windows® 2000 or Windows NT® operating
systems.
For further information on Hitachi Data Systems products and services, please contact your
Hitachi Data Systems account team, or visit the Hitachi Data Systems worldwide web site at
http://www.hds.com.
COMMENTS
Please send us your comments on this document: [email protected].
Make sure to include the document title, number, and revision.
Please refer to specific page(s) and paragraph(s) whenever possible.
(All comments become the property of Hitachi Data Systems Corporation.)
Thank you!
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide v
vi Preface
Contents
Chapter 1 Overview of the Thunder 9580™ V Series Subsystem ........................................................1
1.1 Overview Features ............................................................................... 1
1.1.1 High Data Availability................................................................... 2
1.1.2 Connectivity.............................................................................. 2
1.1.3 Enhanced Data Accessibility ........................................................... 2
1.1.4 Scalability ................................................................................ 3
1.1.5 Performance Reporting and Monitoring.............................................. 3
1.1.6 Reliability, Availability, and Serviceability ......................................... 4
1.1.7 Hitachi Freedom SAN™ and Hitachi Freedom Data Networks™ ................... 5
1.1.8 Hitachi Freedom NAS™ and HDS-NetApp NAS Enterprise Gateways ............. 6
1.2 Rack-Mount Model ................................................................................ 7
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide vii
4.5 Disk Array Groups ............................................................................... 34
4.6 Service Processor (SVP) ........................................................................ 34
4.7 Component Names, Locations, and Functions .............................................. 35
4.7.1 Front Bezel Component Locations and Functions................................. 35
4.7.2 RKH and RKA Component Locations................................................. 36
4.7.3 Switch Locations and Functions ..................................................... 37
4.7.4 Connector Locations and Functions ................................................. 39
4.7.5 LED Locations and Functions ......................................................... 41
viii Contents
7.3 Determining Space and RAID Level Requirements......................................... 64
7.3.1 Setting a Spare Disk ................................................................... 64
7.3.2 Canceling a Spare Disk Setting ...................................................... 65
7.3.3 Setting a RAID Group.................................................................. 66
7.3.4 Deleting a RAID Group ................................................................ 68
7.3.5 Setting a Logical Unit ................................................................. 69
7.3.6 Deleting the Last Logical Unit ....................................................... 70
7.3.7 Invalidating a Logical Unit ........................................................... 71
7.3.8 Restoring a Logical Unit .............................................................. 72
7.3.9 Reallocating a Logical Unit .......................................................... 73
7.3.10 Formatting a Logical Unit ............................................................ 74
7.3.11 Changing the Default Controller in Charge of an LU............................. 77
7.4 Setting Host Group Information .............................................................. 78
7.4.1 Setting Mapping Information ........................................................ 78
7.5 Transferring Configurations from One Array to Another ................................. 83
7.6 Storing Configuration Data .................................................................... 84
7.6.1 System Parameter Information...................................................... 84
7.6.2 RAID Group/LU information ......................................................... 85
7.6.3 Port/Host Group Information........................................................ 86
7.7 Applying Configuration Data to Another Thunder 9580™ V Series Subsystem ......... 88
7.7.1 System Parameters.................................................................... 88
7.7.2 RAID Group/Logical unit.............................................................. 89
7.7.3 Port/Host Group ....................................................................... 89
7.8 Setting the Subsystem When Using Special Mode ......................................... 90
7.8.1 Simple Setting for Connecting to the Host Computer ........................... 90
7.8.2 Special Mode Setting.................................................................. 96
7.9 Changing the Network Parameter........................................................... 132
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide ix
8.4.4 Checking Log Messages.............................................................. 156
8.4.5 Troubleshooting Using Messages................................................... 159
8.4.6 Reading Failure Information........................................................ 163
Appendix A Glossary..............................................................................................................................167
Appendix F Using LUN Security or LUN Management on a Fabric Switch Connection ...................203
x Contents
List of Figures
Figure 2.1 Positions and Contents of Labels on Rack-Mount Model RKH ...................... 17
Figure 2.2 Positions and Contents of Labels on Rack-Mount Model RKA ...................... 18
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide xi
Figure 8.8 Buzzer Volume Screen ................................................................. 152
Figure 8.9 Subsystem Status Screen............................................................... 153
Figure 8.10 Progress Condition Display ............................................................ 154
Figure 8.11 Replace Part Summary Screen (HDD) ................................................ 155
Figure 8.12 Path Information Screen ............................................................... 155
Figure 8.13 Information Message Screen........................................................... 156
Figure 8.14 Message Analysis Example ............................................................. 164
List of Tables
Table 2.1 CAUTION Statements ................................................................... 16
Table 2.2 Symbols Contained in Warning Labels ................................................. 16
Table 2.3 9580V Dimensions and Weight of the Rack-Mount Model ........................... 19
Table 2.4 Internal Logic Specification of the 9580V Rack-Mount Model...................... 21
Table 2.5 Principal Functions of 9580V Cables ................................................... 22
Table 2.6 Environmental Specifications ........................................................... 24
Table 2.7 Input Power and Insulation Performance Specifications for the Rack-Mount
Model (RKH/RKA) ......................................................................... 24
Table 2.8 Vibration and Shock Tolerances ........................................................ 25
Table 2.9 Reliability of the 9580V Rack-Mount Model........................................... 25
xii Contents
Table 8.1 Web Operational Environment ........................................................ 139
Table 8.2 Web Operational Requirements....................................................... 140
Table 8.3 Network Parameters .................................................................... 141
Table 8.4 Message Code Types .................................................................... 159
Table 8.5 Flash Detected Messages ............................................................... 160
Table 8.6 Progress Messages ....................................................................... 161
Table 8.7 Warning Messages ....................................................................... 162
Table 8.8 Failure Messages......................................................................... 162
Table 8.9 How to Read Failure Information ..................................................... 163
Table D.10 List of Capacities Corresponding to RAID 1 (146 Gbytes) ......................... 191
Table D.11 List of Capacities Corresponding to RAID 5 (146 Gbytes) ......................... 192
Table D.12 List of Capacities Corresponding to RAID 1+0 (146 Gbytes) ...................... 193
Table G.1 Number of Logical Blocks and RAID Levels .......................................... 201
Table G.2 Number of Logical Blocks of One Parity Group ..................................... 202
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide xiii
xiv Contents
Chapter 1 Overview of the Thunder 9580™ V Series Subsystem
The Hitachi Freedom Storage™ Thunder 9580™ V Series subsystem is a high-performance,
medium-capacity storage array with added features designed to reduce the possibility of
data loss due to the failure of any single component. Disk array installation and setup are
simplified using the Resource Manager 9500 program (optionally available). Many parts are
replaceable while the disk array is online. Cache memory has a battery backup to preserve
cache contents in the event of a power failure. For information regarding model types, see
section 1.2.
The following Hitachi Freedom Storage™ Thunder 9580™ V Series features are discussed in
this section:
High Data Availability
Connectivity
Enhanced Data Accessibility
Scalability
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 1
1.1.1 High Data Availability
The 9580V is designed for high performance and protection of user data. See section 1.1.6
for additional information on the reliability and availability features of the Hitachi Thunder
9580™ V Series subsystem.
1.1.2 Connectivity
The Hitachi Thunder 9580™ V Series subsystem provides connectivity to most open systems
through a standard Fibre Channel interface.
With the Fibre Channel connection, the 9580V subsystem can transfer data between the
host computer and the subsystem at a maximum speed of 200 MB/sec. The subsystem
can be located up to 300 meters from the host.
The 9580V subsystem enables you to construct a system which can connect up to 126
fibre channel devices by using the fibre channel interface and connecting the fibre-
channel arbitrated loop (FC-AL) and the fibre channel switch (Fabric).
When the system is configured to connect multiple hosts, a function is provided which
rejects a boot by any host except a specified host. This function can prevent access from
an illegal host.
The 9580V supports command tag queuing, multi-initiator I/O, and most industry-standard
middleware products providing host fail-over capability, I/O path fail-over support, and
logical volume management. The 9580V also has many features that increase data
accessibility and enable continuous user data access.
FlashAccess 9500V allows a LUN to reside in cache memory for fastest possible access.
LUNs can be created to suit customer needs using the Resource Manager 9500V.
LUN Security 9500V allows the 9500V to control host access to LUNs by host Worldwide
Name. Up to 128 Worldwide Names per port can be supported.
Up to 2 GBs (one pair of 512 MB DIMMs) of cache memory can be installed in each
controller (or up to 4 GBs per subsystem) to improve I/O performance.
ShadowImage 9500V enables you to maintain subsystem-internal copies of all user data
on the Thunder 9580™ V Series storage subsystem for purposes such as data backup or
duplication.
The architecture of the 9580V enables the user to scale the subsystem to meet a wide range
of capacity and performance requirements.
You can construct a variety of systems; for example, a system with 14 disk drives can be
configured using a single RKH, or a more complex system can be set up using the
maximum of 449 disk drives, expanded by connecting up to 30 RKAs to the RKH.
Up to 15 spare disks can be set up and mounted in any location. Use the system
effectively by mounting each spare disk in a disk drive slot left unused due to system
construction.
Note: Some disk drive slots cannot be used for spare disk. For additional information,
contact Hitachi Data Systems Customer Support.
From the host computer, the subsystem can be used as a single large-scale disk drive or
as 2048 logical disks (LUs) (maximum).
The Resource Manager 9500V program provides the capability to either monitor the disk
array in real time or to collect historical data regarding the performance of the disk array.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 3
1.1.6 Reliability, Availability, and Serviceability
The 9580V subsystem is not expected to fail in any way that would interrupt user access to
data. The 9580V can sustain single component failures and still continue to provide full
access to all stored user data.
Note: While access to user data will not normally be compromised, the failure of any single
key component may degrade performance.
The reliability, availability, and serviceability features of the 9580V subsystem include:
High-Availability capability. The 9580V subsystem provides high-availability capability
for all critical components. The 9580V uses component and function redundancy to
provide high availability for many subsystem components.
The Controller of the Thunder 9580™ V Series subsystem increases data reliability by
adding original 8-byte data assurance codes to data from a host computer by
automatically generating them, writing them in the disk drive together with the data,
and checking them when reading the data. On the data bus in the controller, the
automatic generation of the data assurance codes and the check are executed to
enhance data reliability in data distribution/concentration control, peculiar to the disk
array.
Up to 15 spare disks can be specified per subsystem; this function monitors the potential
disk failure. Before failure occurs, the data copy operation can be automatically
performed in the background. The dynamic sparing feature enables the subsystem to
replace the spare disk due to redundancy (excluding RAID 0 configuration) and provides
high reliability.
Redundant power supply systems. Each 9580V unit has a set of two power supplies.
Each power supply can provide power for the entire subsystem in the unlikely event of
power supply failure. The power supplies of each set can be connected across power
boundaries so that each set can continue to provide power if a power outage occurs.
Each unit of the 9580V can sustain the loss of a single power supply and still continue
operation.
High capacity cache. The Thunder 9580™ V Series subsystem supports a maximum of 2
GBs high capacity cache per controller. Writing completion can be reported to the host
system when data is written to cache.
Hitachi Data Systems’ SAN Solutions enable you to increase data availability, counter
spiraling information management costs, and take advantage of the speed and flexibility of
SAN technology. In addition to supporting the Storage Networking Industry Association’s
open-systems standards, HDS SAN Solutions reduce total cost of ownership by minimizing
support costs and downtime, and optimizing server and storage configurations.
Hitachi Freedom Data Networks™ (FDN) responds to the challenge of open architecture and
multiple platforms. FDN is the locus of Hitachi’s long-term vision for offering businesses
complete freedom of choice in establishing data-centric enterprise networks, encompassing
storage, switches, servers, management software, protocols, services, and networks
developed by Hitachi, our alliance partners, and third party providers. FDN facilitates:
For further information on Freedom SAN™ and Freedom Data Networks™, please contact your
Hitachi Data Systems account team, or visit Hitachi Data Systems online at www.hds.com.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 5
1.1.8 Hitachi Freedom NAS™ and HDS-NetApp NAS Enterprise Gateways
Hitachi Freedom NAS™ enables you to expand configuration alternatives and boost data
access. Freedom NAS enables rapid information access in a modular, rapidly deployed file
server. Combined, HDS NAS and SAN technologies create a single pool of centrally managed
storage, eliminating storage islands and giving you unmatched capacity, performance, and
availability. Freedom NAS is an excellent solution for:
File/Web serving
Document/record imaging
Streaming media
Video design
Telco call centers
Manufacturing
The HDS-NetApp NAS Gateways enable you to consolidate all of your data—SAN and NAS—into
one storage system. The Gateways can be attached directly to the Hitachi Lightning 9900V™
storage subsystems (and Thunder 9500V™) via fiber-channel switch. The Gateways come with
a high-availability clustered configuration as an option, and offer NetApp Data ONTAP™
operating system and all major supporting utilities including Snapshot™ and SnapRestore® for
seamless data backup and recovery.
For further information on Freedom NAS™ and NAS Gateways, please contact your Hitachi
Data Systems account team, or visit Hitachi Data Systems online at www.hds.com.
The rack-mount model is composed of a combination of the RKH and RKA mounted on a rack
frame. The RKH includes a controller to perform RAID control on the drives in RKAs. The RKA
is capable of mounting up to 15 disk drives and controls the drives through a connection with
an RKH. The RKA is provided with no controller.
Note 1: Since the RKH controls the Thunder 9580™ V Series subsystem, at least one RKH must
be mounted. For details, consult with the Hitachi, Sales Division.
Note 2: For additional information about the rack-mount model, refer to the Hitachi Freedom
Storage™ Thunder 9500™ V Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 3: For additional information about the global rack-mount model, refer to the Hitachi
Data Systems Global 19-Inch Rack Reference Guide (MK-92DF665).
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 7
8 Chapter 1 Overview of the Thunder 9580™ V Series Subsystem
Chapter 2 Planning for Installation and Operation
This chapter provides information for planning and preparing a site before and during
installation of the Hitachi Thunder 9580™ V Series subsystem. Please read this chapter
carefully before beginning your installation planning.
If you would like to use any of the 9580V features or products (e.g., LUN Security 9500V,
FlashAccess 9500V), please contact your Hitachi Data Systems account team to obtain the
appropriate license(s) and software key files.
Note: The general information in this chapter is provided to assist in installation planning and
is not intended to be complete. The internal 9580V installation and maintenance documents
used by Hitachi Data Systems personnel contain complete specifications. The exact
electrical power interfaces and requirements for each site must be determined and verified
to meet the applicable local regulations. For further information on site preparation for
9580V installations, contact your Hitachi Data Systems account team or the Hitachi Data
Systems Support Center.
Safety Precautions
General Specifications and Requirements
Environmental Specifications and Requirements
Before the 9580V subsystem arrives for installation, the user must provide the following
items to ensure proper installation and configuration.
Physical space necessary for proper subsystem function and maintenance activity
Electrical input power
Connectors and receptacles
Air conditioning
Floor ventilation areas (recommended but not required)
Cable access holes
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 9
2.2 Safety Precautions
When using the 9580V disk array subsystem, follow these cautionary procedures:
Perform operations in accordance with the instructions or procedures described in this
manual.
It is impossible to describe every hazard that may exist with this equipment. Please be
aware of hazards not described in this manual. Work safely.
The symbol followed by the word “CAUTION” in this manual indicates a potential safety
hazard. When you see this symbol, observe the safety instructions that follow.
Users must not repair, remodel, or disassemble the equipment. Such actions may cause
hazardous conditions for the user and/or the equipment.
2.2.3.1 Equipment
If you notice unusual heat generation, odors, or smoke emission, shut off the power feed to
the equipment and contact the maintenance engineer. Leaving such conditions unattended
may result in hazardous physical conditions and equipment failure.
Avoid physical disruption to the equipment. This may result in hazardous physical conditions
and equipment failure.
Do not place heavy objects on top of the disk array. Avoid using the equipment for any use
other than its original purpose; otherwise, an injury or equipment failure may result.
2.2.3.2 Cables
Do not allow heavy material to be placed on cables. Do not place cables near any apparatus
that generates heat. Do not step on or subject cables or connectors to shearing or pulling
forces; the cable jacket can be damaged and can break, resulting in an electric shock, fire,
or loss of data.
Make sure that electrical and signal cables are clean before connecting them. Any dirt on a
connector should be removed before inserting the connector into a socket.
Make certain that the air vents are free of obstruction. They should be inspected
periodically.
Do not place metallic material such as paper clips or any combustible material such as paper
into or near the air vents. This may result in electric shock or fire.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 11
2.2.3.4 Battery Unit
These instructions explain what you must observe when you use a nickel-hydride
rechargeable battery (hereafter it is referred to as the battery). If you use the battery
incorrectly, it can overheat ignite, burst, or explode, damaging and deteriorating its
performance/life. Read and follow the instructions below:
Danger
1. Do not disassemble the case; do not modify it or peel off the label. There are high
voltage parts inside: if you attempt any of these actions, this can result in electrical
shock or burning.
2. Do not disassemble the battery; this can cause short circuits inside or outside of the
battery. If the components are exposed to the air, the battery can overheat, burst or
ignite. Disassembling the battery can expose you to alkaline solution, which can be
dangerous.
3. Do not cut the output cable. Do not modify the connector. If you attempt any of these
actions, an electrical shock or burn can result. A short-circuit may cause abnormal
chemical reactions inside the battery which leads to overheating, bursting or ignition.
4. Follow the instructions when you recharge the battery pack. If you recharge it in a way
different from specified here, it may cause the following problems: The battery may
become charged excessively; excessive current may be produced; or the battery cannot
be recharged. As a result, the battery may leak, become overheated, burst, or ignite.
5. Do not use excessive force when you connect the battery pack to the charger or other
devices. If you cannot connect it easily, check that the positive and negative positions
are correct for the connector. If you connect the battery in reverse, it will be charged
incorrectly and abnormal chemical reactions may occur inside. As a result, the battery
may become overheated, burst or ignite.
10. Do not let the battery become wet by soaking it in the water or seawater. If the battery
becomes wet, a short circuit can occur and an excessive amount of current can be
produced, causing abnormal chemical reactions inside. As a result, the battery may
become overheated, burst or ignite.
11. Do not nail or hammer the battery. The battery may be broken or dented and a short
circuit may occur inside. As a result, the battery may become overheated, burst or
ignite.
12. Do not solder directly to the battery. If you do so, heat will melt the insulator and
damage the safety fuse/mechanism. As a result, the battery may leak or may become
overheated, burst or ignite.
Warning
13. If you find anything strange or unusual with the battery when you use/carry/store it,
remove the battery from the device and stop using it. For example, strange smells,
strange colors, or deformation are a sign you must stop using the battery.
14. If it takes longer than the specified time to complete recharging, stop recharging the
battery; otherwise, the battery may become overheated, burst or ignite.
If the battery leaks and gets into your eyes, immediately flush your eyes with clean water
(tap water) and do not rub your eye. Visit the doctor immediately. If you do not seek any
treatment for your eyes, problems may occur later. Because the battery uses highly
concentrated alkaline as electrolyte, it can burn; you may lose your sight if it makes
contacts your eyes. If the battery's liquid contacts your skin or eyes, you must flush them
with plenty of clean water and visit a doctor at once.
2.2.3.6 Other
When a failure occurs in the unit, take action according to the procedures recommended in
this manual. If the difficulty does not correspond to the corrective measures documented in
this manual, contact the maintenance engineer.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 13
2.2.4 Precautions for Inspection and Cleaning
If a maintenance activity requires that the unit be powered off, make sure that the
power-off sequence described in the manual is performed before proceeding with
maintenance.
After the power feed to the equipment is shut off, electricity remains in the equipment
for a period of time. Therefore, do not touch any components other than those indicated
in this manual.
The equipment can become extremely hot. Do not touch any part other than those
indicated in this manual.
When working with the door open, wear cotton gloves to prevent your hands from
touching sharp objects.
To shut off the electric flow to a victim, disconnect the power feed cable of the
equipment. In spite of this action, electricity may not be shut off. Separate the victim
from the current source by using a non-conductive material such as dry wooden bar.
Call an ambulance.
When the victim has lost consciousness, practice artificial respiration on the victim. To
prepare for such a case, learn how to practice artificial respiration.
When the victim’s heart has stopped, give a heart massage. This treatment should only
be conducted by a person who has been trained and qualified.
2.2.5.2 Fire
To shut off the electric flow to the equipment, pull out the power feed cable. This will
terminate the power supply.
If a fire cannot be extinguished when the electric flow has been shut off, use fire-
fighting procedures and contact the fire department.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 15
2.2.6 Warning Notices
CAUTION
2.2.6.1 Statements
CAUTION statements described in this manual and the pages where they appear are listed
below.
Cooling fans rotate at a high speed. Keep body parts and loose clothing away 14
from the cooling fans.
When cleaning, take care not to touch electrically charged parts. Electric shock 14, 15
may result.
Warning labels are pasted on sections of equipment which require special care. Read the
messages and observe the warning procedures. They are shown in the following figures:
Table 2.2 lists and describes the symbols contained in warning labels.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 17
42kg.
This section describes the general specifications and requirements for the Thunder 9580™ V
Series subsystem. The following are included:
Dimensions and Weight
Service Clearance Requirements
Floor Load Rating
Internal Logic Specifications
Cable Requirements
Note: 9580V support for dynamic disks is not available at this time under certain operating
conditions. For information about dynamic disks, please contact your Hitachi Data Systems
technical representative.
The following table illustrates the dimensions and weight of the 9580V rack-mount model.
RKH RKA
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 19
2.3.2 Service Clearance Requirements
The following figure shows the floor area required for installing the equipment. Install the
equipment in a place with the area shown in the figure to avoid problems such as inadequate
service clearance or insufficient ventilation. All distances in the following figure are stated
in millimeters (mm).
910
1,000
140
65
42.5 525 42.5
90 430 90
1,000
U6 Rackmount Model
In the maximum configuration, the 9580V rack-mount model can be configured with 1 RKH
and 30 RKAs. The total weight of the subsystem in this configuration is 1,930 kg.
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom
Storage™ Thunder 9500™ V Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi
Data Systems Global 19-Inch Rack Reference Guide (MK-92DF665).
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom
Storage™ Thunder 9500™ V Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi
Data Systems Global 19-Inch Rack Reference Guide (MK-92DF665).
The following table lists the internal logic specifications of the 9580V.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 21
2.3.5 Cable Functions
The following table lists the principal functions of the 9580V cable. Fibre channel cables are
available from Hitachi Data Systems.
Cable Function
LAN Cross cable Connect the PCs for user, monitoring and maintenance
To maintain optimal Thunder 9580V performance, the 9580V subsystem must be installed in
a proper environment. This section discusses the following necessary environmental
specifications and requirements:
Environmental Hazards
Temperature and Humidity Requirements
Input Power and Insulation Performance Specifications
Air Flow Requirements
Vibration and Shock Tolerances
Reliability
Do not install the subsystem in the places described below; the life of equipment
functioning will be shortened and equipment failures will occur. Avoid the following:
Direct sunlight exposure
Temperature and humidity variation (for example, near an air conditioner)
Close proximity to a device that generates electrical noise and motion (for example, air
conditioner that is not grounded and washing machine motor)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 23
2.4.2 Temperature and Humidity Requirements
Table 2.6 lists the temperature and humidity requirements for the 9580V subsystem.
Item Specification
Temperature In operation (°C) 10 to 40
In non-operation (°C) -10 to 50
In transport/storage (°C) -30 to 60
Temperature change rate (°C/h) 10 or less
Humidity In operation (%) 8 to 80
In non-operation (%) 8 to 90
Maximum wet bulb temperature (°C) 29 (non-condensing)
Altitude In operation (m) -300 to 3,000
In non-operation (m) -300 to 12,000
The following tables list the input power and insulation performance specifications for the
9580V rack-mount models.
Table 2.7 Input Power and Insulation Performance Specifications for the Rack-Mount Model (RKH/RKA)
RKH RKA
Note 1: This indicates the current consumption in the usual state. When a power supply failure occurs, the power consumption
is provided by the single power supply for the subsystem.
Note 2: The current value in the operation by a single power supply unit is same as that in the operation by both power supply
units.
The 9580V subsystem is air-cooled. Air must enter the subsystem through the airflow intakes
at the back of each subsystem and must be exhausted out of the front, so it is very
important that the air intakes and outlets remain clear.
Table 2.8 lists the vibration and shock tolerance data for the 9580V subsystem. The 9580V
can tolerate vibration and shock within these limits and continue to perform normally. The
user should consider these requirements if installing the 9580V near large generators located
on the floor above or below the 9580V subsystem. Generators or any other source of
vibration, if not insulated or shock-mounted, can cause excessive vibration that may affect
the subsystem.
Item Specification
Vibration In operation (m/s2) 2.5 or less
In non-operation (m/s2) 5.0 or less
In transport (packed) (m/s2) 5.0 or less
Impact In operation (m/s2) 20 or less
In non-operation (m/s2) 50 or less
In transport (packed) (m/s2) 80 or less
Angle at which the subsystem will turn over (°) 15 or less
2.4.6 Reliability
RKH RKA
Reliability Drop in package No abnormality must be caused by a free drop of level IV.
(JIS Z 0200-1997)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 25
26 Chapter 2 Planning for Installation and Operation
Chapter 3 Powering On/Off Procedure
The disk drive may emit audible mechanical sounds when the disk drive is started (spun up),
immediately after the subsystem is powered on and powered off (spun down). However, this
does not indicate a problem if the WARNING or ALARM LED of the basic frame is off; you may
use the subsystem.
This section describes power on/off procedures for the 9580V Rack-Mount Model.
The following steps describe power on/off procedures for the 9580V rack-mount model.
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom
Storage™ Thunder 9500™ V Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi
Freedom Storage™ Thunder 9500™ V Series Global 19-Inch Rack Reference Guide
(MK-92DF665).
Note: The EALM lamp (red) of the controller (on the rear side of the subsystem) may come on
between subsystem power-on and entry into the Ready status. However, it is not a problem
if the EALM lamp (red) goes out during this period of time.
Note: When two or more disk drives are not installed on the additional disk drive unit
side, shut off the power to the power unit (RKA).
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 27
3.1.2 Subsystem Power Off
1. Turn off the main switch.
2. Verify that the POWER LED (green) on the panel is off.
3. Turn off the AC power unit switch of the power unit.
4. Turn off the circuit breaker (CB1) of the PDB.
Note: When storing the subsystem without turning on the power for long periods, request that
the maintenance engineer turn off the battery of the subsystem. For details on how to store
the subsystem, refer to Chapter 9.
The disk drives can be assigned to data disk(s), parity disk(s) (mirror disk(s)) depending on
the RAID level.
Up to 15 spare disks can be mounted in any location, excluding the HDU#0 to HDU#4 in
unit 0.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 29
: Basic component and indispensable
optional part
: Option (additional) part
Host computer
Power Unit
AC100/200 V
(RKH) #0
(Single phase)
Power Unit
(RKH) #1 AC100/200 V
0A 0B 0C 0D 1A 1B 1C 1D (Single phase)
Backup Battery
Control Unit #0 Control Unit #1
Unit
LAN Cache Unit Cache Unit
LAN
LAN LAN
Fan Assembly
Fan Assembly
14 Fan Assembly
Disk Drive
(Note)
To RKA
14 Fan Assembly
Disk Drive
(Note)
To RKA
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 31
4.2 Redundant Power Supplies
Each 9580V unit is powered by its own set of redundant power supplies, and each power
supply is able to provide power for the entire RKH or RKA unit, should it become necessary.
Because of this redundancy, the Thunder 9580™ V Series subsystem can sustain the loss of
multiple power supplies and still continue operation. To make use of this capability, the two
power supplies of each 9580V unit should be connected either to dual power sources or to
different power panels, so if there is a power failure on one of the sources, the Thunder
9580™ V Series subsystem can continue full operations using power from the alternate
source.
The Thunder 9580™ V Series subsystem supports open system operations. The Thunder 9580™
V Series subsystem supports up to 8 fibre-channel ports. The 9580V Fibre Channel interface
is capable of operating at data transfer speeds of up to 200 MB/sec. The 9580V supports
shortwave multimode optical cables. With these shortwave fibre channel cards, the 9580V
subsystem can be located up to 300 meters from the open-system host.
This section includes specification information about the 9580V rack-mount model array
frames.
Each RKA unit contains the physical disk drives, including the disk array groups and the
dynamic spare disk drives. Each rack frame has dual AC power plugs, which should be
attached to two different power sources or power panels. The 9580V can be configured with
1 RKH and up to 30 RKA units for a total of 449 GB disk drives at a maximum of 64.0 Tbytes
RAID0 (using the 146 G disk drive).
System appearance
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom Storage™ Thunder 9500™ V
Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi Data Systems Global 19-Inch Rack
Reference Guide (MK-92DF665).
Note 3: This value of storage capacity is calculated as 1 Gbyte = 1,000,000,000 bytes. (This definition is different from
1 Kbyte = 1,024 bytes.)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 33
4.5 Disk Array Groups
The RAID group is the basic unit of storage capacity for the Thunder 9580™ V Series
subsystem. All disk drives in a RAID group must have the same logical capacity. When a RAID
group is configured with drives of different capacity, the RAID group is configured by
assuming the minimum capacity of the drives.
Note: Details of the storage capacities, depending on the RAID level and subsystem
configuration, are shown in Appendix E List of Storage Capacities Corresponding to RAID
Levels and Configurations.
The Thunder 9580™ V Series subsystem is controlled by the service processor (SVP). The SVP
is integrated into the controller frame and is accessed through the Resource Manager 9500V
program and service utilities. The SVP enables Hitachi Data Systems representatives to
configure, maintain, and upgrade the 9580V subsystem.
This section illustrates and describes the locations and functions for the front bezel.
Main switch on
BUZZER OFF SW
RKH RKA
Name Function
ALARM LED (red) Indicates that a failure has occurred which makes the subsystem inoperable
WARNING LED (orange) Indicates that a failure occurred, but the subsystem is currently operational
POWER LED (green) Indicates that the power is supplied to the subsystem
BUZZER OFF SW Press this switch when the buzzer sounds to stop the beep. When a serious hardware
failure occurs, (electrical surges of both power supplies and so on), the buzzer does not
stop even when the button is pushed.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 35
4.7.2 RKH and RKA Component Locations
The locations of the RKH and RKA components are shown in the following diagram:
This section illustrates and describes the locations and functions for switches in the
following hardware components:
Panel Assembly
Backup Battery Unit
Power Unit
Main switch
BUZZER OFF SW
Switch Function
BUZZER OFF SW Pressing this switch while the buzzer sounds stops the beep. When a serious hardware
failure occurs, (electrical surges of both power supplies and so on), the buzzer does not
stop even when the button is pushed.
Battery Switch
Switch Function
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 37
4.7.3.3 Power Unit
Switch Function
ENC Unit
Power Unit
Control Unit
Connector Function
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 39
4.7.4.2 Power Unit
Connector Function
FC Connector (Port B)
Connector Function
This section illustrates and describes the locations and functions of LEDs in the following
hardware components:
Disk Drive Display
Battery Backup Unit
ENC Unit
Power Unit
Fan Assembly
Control Unit
Connector Function
HDD ACTIVE LED (green) When on or flashing, it indicates that the disk drive is operational.
HDD ALARM LED (red) When on, it indicates that a failure occurred in the disk drive; the disk drive is inoperable.
WARNING LED (orange) When on, it indicates that a failure occurred in the unit; the unit is inoperable.
POWER LED (green) When on, it indicates that electricity is supplied to the unit.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 41
4.7.5.2 Battery Backup Unit
Connector Function
READY LED (green) When on, flashing, or off, it indicates the condition of the battery.
CHARGE LED (orange) When on or flashing, it indicates the charging status of the battery.
ALARM LED (red) When on, it indicates that a failure occurs in the battery.
Connector Function
P1 LED (green) When on, it indicates that the link status of FC-AL (loop 1 side) is normal.
P0 LED (green) When on, it indicates that the link status of FC-AL (loop 0 side) is normal.
EALM LED (red) When on, it indicates that a failure occurs in the controller (ENC side), so the controller is
inoperable.
ALM LED (red) When on, it indicates that a failure occurs in the ENC Unit, so the ENC Unit is inoperable.
CHK LED (red) It indicates, according to the number of times the LED flashes, what voltage is abnormal.
Once: Logic +5 V voltage is abnormal.
Twice: Drive +12 V voltage is abnormal.
Three times: Logic +3.3 V voltage is abnormal.
Five times: Battery is abnormal.
Six times: Voltage on the controller is abnormal. (Reset of the controller is not canceled)
Seven times: BS 1.8 V, BS 3.3 V, or BS 12 V voltage is abnormal.
Nine times: Fan is abnormal.
The following blinking is fast because ENC microprogram detects CUDG error.
Once: SRAM error
Twice: ENC hard error
Three times: Microprogram error in flash memory
Not blinking: Boot section error of ENC microprogram, RAM error, or ENC hard
configuration error
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 43
4.7.5.4 Power Unit (RKH/RKA)
Connector Function
ALARM LED (red) When on, it indicates the abnormal or in a stop state.
Connector Function
ALARM LED (red) When on or off, it indicates the operating status of the fan assembly.
on: It is abnormal.
off: It is operating normally or in a stop state.
Connector Function
CACHE POWER LED (green) When on or off, it indicates the status of the cache memory backup operation.
on: Backup operation is in execution.
off: Backup operation is not in execution.
RST LED (orange) When on, it indicates that the controller is under resetting.
CALM LED (red) When on, it indicates that a failure occurs in the controller (CTL side), so the controller is
inoperable.
GP0 LED (green) It indicates the status of the interface installed in the controller as standard.
GP1 LED (green) It indicates the status of the interface installed in the controller as standard.
CHKSTP LED (red) When on, it indicates that a failure occurred in the controller (CTL side); the controller is
inoperable.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 45
46 Chapter 4 Subsystem Architecture and Components
Chapter 5 Functional and Operational Characteristics
This chapter includes a description of the following:
New 9580V Features and Capabilities
RAID Implementations
Cache Management
Logical Units
Open System Features and Functions
Data Management Features and Functions
Copy Solution Features and Functions
The Hitachi Thunder 9580™ V Series subsystem offers the following new or improved features
and capabilities, which distinguish the 9580V subsystem from the 9200 subsystem:
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 47
5.2 RAID Implementations
The Thunder 9580™ V Series subsystem supports RAID0, RAID0+1, RAID1, RAID5 or an
intermix.
RAID1+0 groups provide data redundancy like RAID 1 by copying all the contents of two
disk drives to another pair. Different from RAID 1, data striping is performed for a
maximum of 8 sets of two disk drives.
RAID1 array groups consist of at least two disk drives in a mirrored configuration. Data is
mirrored across the groups of two adjacent drives. The stripe consists of two data
chunks.
RAID5 uses from 2 to 5 data disks and has a parity disk performing the data striping.
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom Storage™ Thunder 9500™ V
Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi Data Systems Global 19-Inch Rack
Reference Guide (MK-92DF665).
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 49
5.3 Cache Management
The data written onto the cache is saved in the event of an electric power failure due to
the nonvolatile cache. The data is assured for 24 hours on the full charge of a standard
configuration.
One specified logical unit on each controller can be resident in cache. High throughput
can be realized for the specified logical unit since a 100% cache percent hit rate is
expected when reading and writing from the host.
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom Storage™ Thunder 9500™ V
Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi Data Systems Global 19-Inch Rack
Reference Guide (MK-92DF665).
The 9580V supports up to 2048 LUNs. Each LU is identified by fibre-channel port ID and LUN
number.
subsystem subsystem
LUN
0 to 2047
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 51
5.5 Open Systems Features and Functions
The Thunder 9580™ V Series subsystem offers many features and functions specifically for
the open-systems environment. The 9580V subsystem also supports important open-system
functions such as fibre-channel arbitrated-loop (FC-AL) and fabric topologies, command tag
queuing, multi-initiator I/O, and most industry-standard software and middleware products
which provide host fail-over, I/O path fail-over, and logical volume management functions.
Open-system middleware products provide host fail-over capability, I/O path fail-over
support, and logical volume management in the open-systems environment. Middleware is
supplied as a usual accessory or an extra-cost optional package.
Each LUN can be assigned to multiple fibre-channel ports to provide I/O path fail-over with
middleware support.
The FlashAccess function ensures that all data in an LU is stored in cache memory. All
read/write commands to the LU can be executed by cache hit 100% without accessing the
drive. The system throughput is improved when this function is applied to an LU that
contains data accessed frequently because no latency period is needed to access the disk
drive.
For additional information, refer to the Hitachi Freedom Storage™ Thunder 9500™ V Series
FlashAccess 9500V User’s Guide (MK-92DF612).
The Fibre Security function prevents data from being destroyed by illegal accesses. Only
specified hosts are permitted to access LUNs (Host Storage Domain).
This function enables the subsystem to respond to each connected host (even within the
same port) by grouping connected hosts within a port and setting the logical unit mapping
and the Host Connection mode for each host group.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 53
5.7 Copy Solution Features and Functions
The 9580V subsystem provides features and functions which allow you to maintain remote
and subsystem internal copies of all user data on the 9580V storage subsystem for data
backup or duplication. These features include:
Synchronous TrueCopy 9500V
ShadowImage 9500V
QuickShadow 9500V
Synchronous TrueCopy operations are non-disruptive and allow the primary (main) volume of
each volume pair to remain online to all hosts for both read and write I/O operations. Once
established, Synchronous TrueCopy operations continue unattended to provide synchronous
remote data backup. Usability is further enhanced through a resynchronization capability
that reduces data duplication requirements and backup time, thereby increasing user
productivity.
For additional information, refer to the Hitachi Freedom Storage™ Thunder 9500™ V Series
Synchronous TrueCopy 9500V User’s Guide (MK-92DF608).
ShadowImage 9500V operations are non-disruptive and allow the primary (main) volume of
each volume pair to remain online to all hosts for both read and write I/O operations. Once
established, ShadowImage 9500V operations continue unattended to provide asynchronous
internal data backup. Usability is further enhanced through a resynchronization capability
that reduces data duplication requirements and backup time, thereby increasing user
productivity.
For additional information, refer to the Hitachi Freedom Storage™ Thunder 9500™ V Series
ShadowImage 9500V User’s Guide (MK-92DF607).
Configure the Thunder 9580™ V Series Subsystem for the Desired Application
General Configuration of the Thunder 9580™ V Series Subsystem
Starting the Parameter Wizard in Resource Manager 9500V
Configuring the Basic Parameters for the Thunder 9580™ V Series Subsystem
Alternate Pathing
The Thunder 9580™ V Series subsystem uses the HP9000 series, SUN Fire series, SUN
Enterprise series, RS6000 Family, and each vendor PC (Net Ware 5.0, Linux, Windows NT 4.0,
and Windows 2000, Me, XP) as a supported platform. Installation for each open system is
required.
The Resource Manager 9500V software enables the user to define the LUN mapping for each
device and reconfigure the mapping at any time. For further information on Resource
Manager 9500V, please refer to the Hitachi Freedom Storage™ Thunder 9500™ and 9200™
V Series Resource Manager User’s Guide Graphical User Interface (GUI), MK-92DF605, to use
a GUI interface. See the Hitachi Freedom Storage ™ Thunder 9500 ™ and 9200™
V Series Resource Manager User’s Guide Command Line Interface (CLI), MK-92DF603, to use
the CLI version. You can also contact your Hitachi Data Systems account team.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 55
6.1.3 Fibre Channel Interface Addressing
The 9580V subsystem supports a maximum of 8 fibre-channel ports. Each fibre-channel port
is assigned a unique target ID number. The 9580V can address up to 2048 LUNs per port. The
following figure illustrates fibre port-to-LUN addressing.
subsystem subsystem
Fibre Channel
port
LUN
0 to 2047
The user should plan for alternate pathing to ensure the highest data availability. The 9580V
provides up to 8 fibre channel ports or to accommodate alternate pathing for host
attachment. The following figure shows a sample of alternate pathing.
LAN
Host A Host B
(active) (standby)
Host capable of switching the path Host switching
is not required
Automatic path switching
FIBRE FIBRE
FIBRE FIBRE
Adapter 0 Adapter 1
Failure
occurrence FIBRE Cable
0A 0B 0C 0D 1A 1B 1C 1D
LU0
LU1
9580V Subsystem
If the Resource Manager 9500V program is used to configure the IP addresses, also refer to
the procedure in section 7.9.
If you wish to use Resource Manager 9500V to configure the IP addresses, please refer to the
Hitachi Freedom Storage™ Thunder 9500™ and 9200™ V Series Resource Manager User’s
Guide Graphical User Interface (GUI), MK-92DF605, to use a GUI interface. Refer to the
Hitachi Freedom Storage ™ Thunder 9500 ™ and 9200™ V Series Resource Manager 9500V and
9200™ User’s Guide Command Line Interface (CLI), MK-92DF603, to use the CLI version.
2. Install Resource Manager 9500V on the system that will be used as the management
PC/Server.
See the Hitachi Freedom Storage™ Thunder 9500™ and 9200™ V Series Resource Manager
User’s Guide Graphical User Interface (GUI), MK-92DF605, to use a GUI interface. See
the Hitachi Freedom Storage ™ Thunder 9500 ™ and 9200™ V Series Resource Manager
User’s Guide Command Line Interface (CLI), MK-92DF603, to use the CLI version.
Refer to the section titled “Installing Resource Manager 9500V” for instructions on how
to install the program.
3. Register the disk array for control by Resource Manager 9500V.
4. Set the system parameters using the appropriate installation guide for the desired host
platform(s).
6.4 Registering the Thunder 9580™ V Series Subsystem for Control by Resource Manager 9500V
To operate the array unit from Resource Manager 9500V, register the array unit. You cannot
temporarily register a non-existing array unit.
1. On the Add menu, click Register Array Unit or click Register Array Unit button in the
tool bar.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 57
6.5 Configure the Thunder 9580™ V Series Subsystem for the Desired Application
Before configuring the 9580V make sure that you know the following:
The required RAID level, based on performance and pricing criteria
The number and size of LUNs you wish to create
The controller path you wish to use to access the data on the LUNs
If there are any special options that need to be set that are specific to the host
platform(s) being used. These will be detailed in the Host Installation Manual for the
host platform being used.
Activating Management mode in Resource Manager 9500V will enable you to do a general
configuration of the 9580V subsystem. Before it is possible to configure the 9580V,
management mode must be enabled in Resource Manager 9500V. Otherwise, it is only
possible to monitor the status of the 9580V.
2. Enter New Password and New Password (for confirmation) and click the OK button.
Specify a password of up to 12 alphanumeric characters.
3. On the File menu, click Change Mode or click Change Mode button in the tool bar.
4. When the password-input screen appears, input a password and click the OK button.
Management Mode is displayed in Active Mode: in the upper part of the Main screen.
The Resource Manager 9500V program will operate in Management Mode.
3. The System Startup Settings window displays the items that are currently set. Check
the displayed contents on the window and set each displayed item to the desired
configuration.
To perform the next setting, click the Next button. When you click the Back button, the
previous window will appear.
To stop the setting, click the Cancel button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 59
4. Common 1, Option 1, and Option 2 screens are shown. Perform the settings for each
item. For options, you can make multiple selections.
5. The window for the Option 2 setting is the final window. Click the Next button, then
display Detailed Settings.
If you set the Detailed Settings items in succession, select Yes or select No, and then
click the Next button.
When you select No, the System Parameter Setting Completed screen will be displayed.
When the setting is completed, restart the array unit; connect it to the host and the
Resource Manager 9500V program.
Software Composition
Setting Fibre Channel Information
Determining Space and RAID Level Requirements
Setting Host Group Information
Transferring Configurations from One Array to Another
Storing Configuration Data
Applying Configuration Data to an Additional Thunder 9580™ V Series Subsystem
Changing the Network Parameter
Microprogram
System Parameters
Configuration Information
SNMP Information
Storage for Parameters
7.1.1 Microprogram
System parameters are necessary to start the subsystem (from turning on the main switch to
generation of the RDY LED (green). System parameters are stored in flash memory and disk
drives. System parameters will be backed up automatically onto a disk drive when system
parameters are set or changed.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 61
7.1.3 Configuration Information
The configuration information is a record of customer data on the subsystem, such as the
RAID configuration and LU capacity. The configuration information exists in the disk drive
when the main switch is turned off; it is transmitted onto the main memory of the controller
when the main switch is turned on. When configuration information is changed, the
information on the disk drive is updated simultaneously.
The SNMP parameter enables the SNMP function to operate effectively. When SNMP
information activates the SNMP function, the template contained in the SNMP information
(in the SNMP directory on the provided CD-R) is edited and registered in the subsystem.
When updating this information, edit the SNMP information (in the SNMP directory on the
provided CD-R) and register it in the subsystem.
The storage areas where the parameters on the controller are stored are described in the
following table:
1 Fixed Part Program Flash Memory The parameters are stored in flash memory. No
Flash Program (and backup FD) provision of storage against a power shut off is
required for the parameters because flash memory can
System Parameters retain information when power is shut off.
Parameters can be backed up to the following:
• Fixed part program: Cannot be backed up program
• Flash program: Automatically backed up to the
system area
• System parameters: Automatically backed up to the
disk drive
2 Microprogram Disk Drive (System Area) Generally, information in a RAM is erased when the
Configuration Information main switch is turned off. Therefore, the subsystem
also stores the parameters used on the RAM on the
SNMP Information disk drive. (An area is reserved in the disk drive to
store them. This area is called the system area.)
The system area is provided on the disk drives #0 to
#4 in the RKA unit #0 frame. Therefore, the system
area has redundancy for disk drives #0 to #4 in the
RKA unit #0 frame.
Follow the steps below to set and display fibre channel information:
Note: Back up all data before performing this procedure. (If a mistake in operation is made,
user data in the subsystem can be lost.)
1. Turn on the power supply.
2. Start the Resource Manager 9500V program and set the operation mode in the
Maintenance Mode.
3. Click the icon of an array unit on the Main window and select the Settings menu. Click
Display Details or click the Display Details button in the tool bar.
4. On the Settings menu, click Configuration Settings or click the Configuration Settings
button in the tool bar.
5. Click the Fibre Channel tab.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 63
7.3 Determining Space and RAID Level Requirements
This process will depend on the customer requirements, however Hitachi Data Systems
recommends certain configuration guidelines that will provide good performance and
adequate protection of data integrity in most circumstances.
This function can be used in the device ready state (R/W cannot be executed from the host
in operation. When a host command is received, Not Ready is reported to the host
computer).
Note: Disk drives that can be set as spare drives do not yet have a defined RAID group; this
excludes disk drive #0 to #4 in Unit 0.
Data disk
Spare disk
1. On the Settings menu, click Configuration Settings or click the Configuration Settings
button in the tool bar.
2. To cancel the spare drive setup, click the icon of the disk drive to be canceled.
3. The confirmation message for spare drive canceled is displayed. Click the OK button.
4. A message is displayed, stating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 65
7.3.3 Setting a RAID Group
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 67
7.3.4 Deleting a RAID Group
Note: All user data on all LUNs will be lost if all RAID groups are deleted. Backup the user
data before performing this operation.
The unified LU cannot be unified or split unless the LU unifying function (a priced option) is
validated. When a unified LU is defined, the RAID group cannot be deleted. Delete the RAID
group after splitting all the unified LUs in the RAID group. For the procedure for splitting a
unified LU, refer to the LU Unifying Function User's Guide.
3. A message appears, requesting confirmation to delete all RAID groups. Click the OK
button.
The deleted RAID group is updated and a window is displayed.
Note: All user data on all LUNs will be lost if all RAID groups are deleted. Backup the user
data before performing this operation.
If the “Unified LU” function has been enabled, make sure that no unified LUs are present in
the RAID group to be deleted. It will be impossible to delete a RAID group containing unified
LUs until the unified LUs are split.
Delete the RAID group after splitting all the unified LUs in the RAID group. Refer to the LU
Unifying Function User's Guide for the procedure for splitting a unified LU.
When a logical unit is deleted, user data is erased. Perform the deletion after verifying the
number of the logical unit to be deleted and backing up the data.
7. A created logical unit number is displayed for the Logical Unit No. and the RAID group
number in which logical units are defined for the RAID Group. Additionally, a logical unit
capacity that can be created is displayed.
Note: To specify a size explicitly in figures, select a unit to specify the size from among
the GB, MB, and Block. Specify the size to be allocated in decimal number. The
subsystem can be divided into a maximum of 2048 logical units.
Note: The logical unit number may be set optionally when the logical unit is created.
However, logical unit number 0 is assigned to the logical unit created first.
9. The set logical unit information is updated and the window is displayed.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 69
7.3.6 Deleting the Last Logical Unit
Note: The last logical unit is the final logical unit, which is unified. Delete the final logical
unit after verifying its number.
When any logical unit is deleted, the user data in the logical unit will be lost.
1. Click the Logical Status tab on the Unit window.
2. On the Settings menu, select Logical Unit and click Delete Last Defined Logical Unit.
3. A confirmation message is displayed indicating whether or not the last logical units
should be deleted.
Click the OK button, and last logical units will be deleted. When any logical unit is
deleted, the user data in the logical unit will be lost.
The logical unit information in which the last logical unit has been deleted is updated
and the window is displayed.
To invalidate a logical unit which has already been set, follow these steps:
3. A message appears, inquiring whether or not the logical unit should be invalidated.
Click the OK button, and logical unit will be invalidated.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 71
7.3.8 Restoring a Logical Unit
To restore a logical unit which has already been invalidated, follow these steps:
3. A message appears, inquiring whether or not the logical unit should be restored.
Click the OK button, and the logical unit will be restored.
To reallocate a logical unit which has been invalidated, follow these steps:
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 73
7.3.10 Formatting a Logical Unit
Note: When logical units are formatted, the user data will be initialized and completely
deleted.
Offline Format
If multiple logical units are specified, up to six logical units are formatted concurrently,
and the progress of formatting is displayed.
When formatting two or more logical units concurrently online, the command from a
host terminates abnormally. Format each LU one by one following the procedure for
Online formatting.
When Offline Format is executed, the Resource Manager 9500V program cannot be used
for other operations until the formatting of all selected LUs is completed. Do not
terminate the Resource Manager 9500V program before completing “Offline Format”.
Perform the Offline (Queue) format when Password Protection is unlocked and enabled.
When the logical units are configured for each drive, the time required for the
formatting is reduced by 30 to 50 (%).
Quick Format
This mode enables the subsystem to start its operation earlier by formatting the
specified LU in the background to make it usable by a host. Up to 512 LUs can be
specified for quick formatting. This number can also be increased. However, the number
of LUs that can be simultaneously formatted in the background is six per CTL. When
executing “Quick” formatting, the Resource Manager 9500V program can perform
operations (such as a RAID group creation) while the formatting is being executed.
When the Resource Manager 9500V program is terminated while “Quick” formatting is
executed, the formatting function is continued. When the Resource Manager 9500V
program is terminated while “Quick” formatting is executed, the formatting progress is
displayed by percentage in the logical unit status column when the Resource Manager
9500V program is activated again.
Note: When formatting a logical unit with a logical unit capacity less than 100,000 (blocks),
formatting may terminate abnormally. When formatting a logical unit with a logical unit
capacity of 100,000 (blocks), select Online Format.
1. Click the icon of a logical unit on the Unit window. On the Settings menu, select Logical
Unit and click Online Format, Offline Format, or Quick Format.
When you select multiple logical units, hold down the Ctrl key and click the icons of the
logical units to format.
To confirm the latest progress rate, refresh the display by clicking the Refresh button.
Note: When a specified logical unit is formatted, the user data within the specified logical
unit is lost. When incorrectly specifying an logical unit, press the Cancel button and redo
processing by selecting an logical unit to be reformatted.
4. When specifying the Offline/Online format:
When a message is displayed indicating that the specified logical unit has been
formatted, click the OK button.
The screening corresponding to the formatted logical unit is displayed.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 75
5. When specifying the Quick format:
Normal is displayed in the Status box.
02-xxxx, 03-xxxx, 04-xxxx or 0B-xxxx For the above code, a hardware fault is assumed. If the fault is not recovered
after re-execution, contact Hitachi Data Systems.
05-xxxx For the above code, an operation error is assumed. Upon checking the
following items and re-execute processing. If the error is not recovered,
contact Hitachi Data Systems.
05-2600 In spite of none of drive mounted states, is ALL RAID specified and is an
logical unit specified for ALL CAPA formatted?
05-2580 Is an attempt made to define an logical unit exceeding the capacity of the
defined RAID group?
An error occurred in the communication with The message indicating that An error occurred in the communication
an array device. with an array device. at the time when selecting Online Format is output
since the progress window cannot be displayed due to the interface failure
between the Resource Manager 9500V program and a device.
For logical unit formatting, only the logical unit being executed is
continuously formatted.
Note: The controller in charge of a default LU can be changed only for the dual active mode
configuration of a dual system.
5. On the Settings menu, select Logical Unit and select Change Default Controller.
A message appears, requesting confirmation to change the default controller.
6. Click the OK button and default controller in charge of a logical unit will be changed.
7. A message appears, stating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 77
7.4 Setting Host Group Information
In the 9200, the Host Connection Mode was set for each port, and the port and host to be
connected each other were fixed. In the 9580V, the Host Connection Mode, the mapping
information of Logical Unit, and LUN security information are set to the group of hosts, not
to the host. This enables you to select the host computer to which the subsystem is
connected depending on each group of hosts.
Among the host groups, only the 000:G000 is supported. With the microprogram of revision
0652 or later, up to 128 host groups can be set when the onerous optional feature, LUN
Management is used.
Modify Host Group Option is a function that integrates the Host Connection Mode 1 and 2 on
the System Parameter in the 9200.
1. On the unit window, click the Host Groups tab.
2. On the unit window, double-click the Controller to be set for the connection mode with
the host. Display the 000:G000 by double-clicking the Port.
3. Display the Option and Logical Unit by clicking 000:G000, then click Option.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 79
6. Click the Logical Unit.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 81
The mapping information is updated and the following window is displayed.
Output the configuration information of the array unit in a text file or set configuration
using a text file. The configuration information output in a text file includes the status of
the system parameters, RAID group/logical unit and the constituent parts of the array unit.
The configuration to be set includes the system parameters and RAID group/logical unit. The
status of the constituent parts of the array unit cannot be set.
Configuration information is handled with separate text files for the system parameters and
for RAID group/logical unit.
Note: IP addresses will be reset based on file input. The user must edit the text file to
include the correct IP addresses in order to transfer a configuration from one unit to
another.
Editing a text file to set an array unit can be executed, but it is recommended that this
function be used for the configuration of the same array unit. To change the configuration,
use individual functions.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 83
7.6 Storing Configuration Data
To output the setting of the system parameters for an array unit in text form to a specified
file:
1. On the Settings menu, select Configuration Settings or click Configuration Settings
button in the tool bar.
2. Click the Constitute tab.
4. Click the Browse button. Specify the directory and file name to which the configuration
file will be output.
5. Click the Output button.
System parameter information is saved in the form of a text file with the specified file
name.
To output the RAID group/logical unit definition information already set in an array unit to a
specified file in a text format:
1. On the Settings menu, select Configuration Settings or click Configuration Settings
button in the tool bar.
2. Click the Constitute tab.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 85
6. A message appears, confirming that the system parameter information is output with the
specified file name. Click the OK button.
RAID group/LU information is saved in the form of a text file with the specified file
name.
4. Click the Browse button, and specify the directory and file name to output the file of
the configuration.
Port/Host group information is saved in the form of a text file with the specified file
name.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 87
7.7 Applying Configuration Data to Another Thunder 9580™ V Series Subsystem
This section includes the following:
System Parameters
RAID Group/Logical Unit
Port/Host Group
Use the modes discussed in this section only when recommended by an Hitachi Data Systems
Host or Optional Product installation guide.
Set the system parameters in the array unit with the information described in the file. If you
set the system parameters using a file that was output when a priced optional feature is in
an unlocked state, the setting may terminate abnormally. To set system parameters, use a
file that was output when all priced optional features are in a locked state.
For a dual system, the setting cannot be executed if one of the controllers is detached.
Confirm that the array unit is operating normally.
When system parameters are set, the array unit cannot execute commands from the host.
The functions of Resource Manager 9500V can no longer work with the exception of the
Wizard for setting the system parameters and failure monitoring. After setting, restart the
array unit. Confirm that it is operating successfully, then connect to the host and the
Resource Manager 9500V management program.
1. Edit the file for which you will set system parameters to set the array unit. This file has
a specified format. The format of the file is the same as that of the file output by the
array unit. To format a file, refer to the file output in section 7.6.
2. On the Settings menu, select Configuration Settings or click Configuration Settings
button in the tool bar.
3. Click the Constitute tab.
4. Click the System Parameter radio button.
5. Click the Browse button, and specify the directory and file name of the file that
describes the system parameters edited in 1. The specified file name will be shown in
the text box.
6. Click the Input button.
Note: To validate the set system parameters, restart the array unit. The previous settings
stay valid until restarting. The array unit cannot access the host until the reboot is
completed and the system restarts. Therefore, be certain the host has stopped accessing
data before beginning the restart process.
Note: Back up all data before performing this procedure. All user data is lost when the logical
unit is deleted.
Set the array unit according to the RAID group/logical unit setting information described in a
file. If the setup of RAID group/logical unit is configured and completed, all user data
previous data will be lost; RAID group/logical unit configuration as specified in the file will
be set after deleting the current RAID group/logical unit. If user data is needed, configure
the setting after backing up the system.
1. Edit the file for which you will set system parameters to set the array unit. This file has
a specified format. The format of the file is the same as that of the file output by the
array unit. To format a file, refer to the file output in section 7.6.
2. On the Settings menu, select Configuration Settings or click Configuration Settings
button in the tool bar.
3. Click the Constitute tab.
4. Click the RAID Group/Logical Unit radio button.
5. Click the Browse button, and specify the directory and name of the file that describes
the RAID group definition and logical unit definition edited in 1. The specified file name
will be shown in the text box.
6. Click the Input button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 89
7.8 Setting the Subsystem When Using Special Mode
There are two methods for setting options:
Set the host group options (host connection mode 1 and 2) that are necessary for the host
computer to be connected. To do this, select the environmental elements of the host, such
as platform, alternative path, fail-over, and additional parameter. Some host environments
require a detailed setting as well as the simple setting. For details, refer to Table B.2.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 91
Table 7.3 Simple Setting Item List
6. Click the Detail button, as needed. Select Host Connection Mode 1 and Host
Connection Mode 2 and click the OK button. (The routine is returned to Figure 7.7)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 93
7. Click the OK button in the Option (Simple) property.
8. A confirmation message appears. Click the OK button.
9. A message appears requesting you to verify that an I/O requested by the host has been
stopped. Stop it and click the OK button.
10. A message appears, stating that the setting is complete. Click the OK button.
12. Set the settings for the rest of the ports in the same way.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 95
7.8.2 Special Mode Setting
This section includes the following:
Using Resource Manager 9500V
Using the I/O Bus Switching Function in the Sequent NUMA-Q Connection
Using the Subsystem in LU Blockade Mode
Using the WolfPack Mode
Using VxVM (Version 3.2P2+PP or later) on the Host Side
Making Eight or More LUs Recognized by Using Qlogic HBA or Emulex HBA on Windows
2000/NT
Making Eight or More LUs when the Subsystem is Connected to the HP Server
Using the SUN Cluster 3.0
When using the VERITAS Database Edition/Advanced Cluster for Oracle RAC (Solaris)
When using the GF825/GF825C
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 97
Perform the appropriate operation corresponding to the model to be set.
For detailed operation, see the following table:
Note: The procedure for changing to special mode is performed when the host group setting
is in normal mode.
Operations Page
Making Eight or More LUs Recognized by Using Qlogic HBA or Emulex HBA on Windows 108
2000/NT
Making Eight or More LUs when the Subsystem is Connected to the HP Server 110
Using the VERITAS Database Edition/Advanced Cluster for Oracle RAC (Solaris) 126
3. On the Settings menu, select Modify Host Group Option and click Detail.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 99
4. Select the TRESPASS Mode in Host Connection Mode 1. Click the OK button.
12. A message appears, stating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 101
7.8.2.3 Using the Subsystem in LU Blockade Mode
1. On the Settings menu, click System Parameter Wizard or click the System Parameter
Wizard in the tool bar.
5. Click the Next button until System Parameter Setting Completed is displayed.
6. Click the OK button.
7. When the system parameters setting is complete, the following window is displayed.
The Unit screen is closed. To perform other operations on the Main screen, select an
array unit from the Main screen and open the selected Unit screen.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 103
7.8.2.4 Using the WolfPack Mode
1. In the unit window, click the Logical Unit tab. Double-click the Controller to be set for
the connection mode with the host. Display 000:G000 by double-clicking the Port.
Display the Option and Logical Unit by double-clicking 000:G000 and select Option.
2. On the Settings menu, select Modify Host Group Option and click Detail.
4. Select the Reset Target (Reset Bus Device) Mode and Reset Logout of Third Party Process
Mode in Host Connection Mode 2.
Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 105
7. A message appears stating that the setting is complete is displayed. Click the OK button.
5. A message appears indicating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 107
7.8.2.6 Making Eight or More LUs Recognized by Using Qlogic HBA or Emulex HBA on
Windows 2000
1. On the unit window, click the Logical Unit tab. Double-click the Controller to be set for
the connection mode with the host, then display the Host group 0 by double-clicking the
Port.
Display Option and Logical Unit by double-clicking the 000:G000 and select the Option.
2. On the Settings menu, select Modify Host Group Option and click Detail.
5. A message appears and asks you to verify that an I/O requested by the host has been
terminated. Check it and click the OK button.
6. A message appears, stating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 109
7.8.2.7 Making Eight or More LUs Recognized when the Subsystem is Connected to the HP Server
1. On the unit window, click the Logical Unit tab. Double-click the Controller to be set for
the connection mode with the host, then display 000:G000 by double-clicking the Port.
Display the Option and Logical Unit by double-clicking 000:G000 and select Option.
2. On the Settings menu, select Modify Host Group Option and click Detail.
5. A message appears and asks you to verify that an I/O requested by the host has been
terminated. Check it and click the OK button.
6. A message appears stating that the setting in complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 111
7.8.2.8 Using SUN Cluster 3.0
1. On the unit window, click the Logical Unit tab. Double-click the Controller to be set for
the connection mode with the host, then display 000:G000 by double-clicking the Port.
Display the Option and Logical Unit by double-clicking 000:G000 and select Option.
2. On the Settings menu, select Modify Host Group Option and click Detail.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 113
7.8.2.9 Using the ftServer
1. On the unit window, click the Logical Unit tab. Double-click the Controller to be set for
the connection mode with the host. Display 000:G000 by double-clicking the Port.
Display Option and Logical Unit by double-clicking 000:G000; select Option.
2. On the Settings menu, select Modify Host Group Option and click Detail.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 115
7.8.2.10 Using Synchronous TrueCopy
1. On the unit window, click Logical Unit tab. Double-click the Controller to be set for the
connection mode with the host. Display 000:G000 by double-clicking Port.
Display Option and Logical Unit by double-clicking 000:G000 and selecting Option.
2. On the Settings menu, select the Modify Host Group Option and click Detail.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 117
7.8.2.11 Using the Microsoft Cluster Server
When connecting to Microsoft Cluster Server via Fabric Switch, Zoning on Fabric Switch must
be set for each HBA as shown below:
LAN
Host
Microsoft
Cluster Server
HBA#1 HBA#2
0A 1A
CTL0 CTL1
LU0
LU1
LAN
Host-A Host-B
Microsoft Microsoft
Cluster Server Cluster Server
HBA#1 HBA#2 HBA#3 HBA#4
: Zoning
0A 1A
CTL0 CTL1
LU0
LU1
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 119
7.8.2.13 Using the Egenera Blade Frame
1. On the unit window, click the Logical Status tab.
2. Double-click the Host Groups tab. Double-click the Controller to be set for the
connection mode with the host, then display 000:G000 by double-clicking the Port.
Display the Option and Logical Unit by double-clicking 000:G000 and select Option.
3. On the Settings menu, select Modify Host Group Option and click Simple.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 121
7. A confirmation message appears. Click the OK button.
8. A message appears requesting you to verify that an I/O requested by the host has been
stopped. Stop it and click the OK button.
9. A message appears stating that the setting is complete. Click the OK button.
3. On the Settings menu, select Modify Host Group Option and click Simple.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 123
4. Option (Simple) property is opened.
Select the Tru64 for the Platform and TruCluster for the Failover.
Click the OK button.
6. A message appears requesting you to verify that an I/O requested by the host has been
stopped. Stop it and click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 125
7.8.2.15 Using the Veritas Database Edition/Advanced Cluster for Oracle RAC (Solaris)
1. On the unit window, click the Logical Status tab.
2. Double-click the Host Groups. Double-click the Controller which you want to set for the
connection mode with the host, and then display the 000:G000 by double-clicking the
Port.
3. Display the Option and Logical Unit by double-clicking the 000:G000, and select the
Option.
4. On the Settings menu, select Modify Host Group Option and click Simple.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 127
8. A confirmation message appears. Click the OK button.
9. A message appears requesting you to verify that an I/O requested by the host has been
stopped. Stop it and click the OK button.
10. A message appears stating that the setting is complete. Click the OK button.
3. On the Settings menu, select Modify Host Group Option and click Simple.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 129
4. Option (Simple) property is opened.
Click the Additional Parameters button.
8. A message appears requesting you to verify that an I/O requested by the host has been
stopped. Stop it and click the OK button.
9. A message appears stating that the setting is complete. Click the OK button.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 131
7.9 Changing the Network Parameter
To set a network parameter from the Resource Manager 9500V program, use the following
procedure:
Note: When a restart is initiated, the array unit is not ready to access data from the host for
duration of this process. Therefore, verify that the host has stopped accessing data before
initiating a restart.
10. A message appears, stating that the restart has terminated. Click the OK button.
When the OK button is clicked, the unit window is closed. To perform other operations,
select an array unit on the main window and open the unit window.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 133
134 Chapter 7 Configuring Storage on the Thunder 9580™ V Series Subsystem
Chapter 8 Troubleshooting
The Hitachi Freedom Storage™ Thunder 9580™ V Series subsystem provides high data
availability and is not expected to fail in any way that would prevent access to user data.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 135
8.1.1 The POWER LED does not Turn On
When the POWER LED does not turn on, follow these steps:
1. Set the AC power unit switch on; set the main switch to on.
2. Has the POWER LED turned on?
Yes: Go to step 9.
No: If the power control has been set to Remote, power-on the host computer.
3. Has the POWER LED turned on?
Yes: Go to step 9.
No: Set the main switch to off; set the AC power unit switch to off.
4. Check the PDB to verify that electricity is supplied to the unit.
5. Verify that the AC cable is correctly connected to the plug socket and the equipment.
6. Set the AC power unit switch to on; set the main switch to on.
7. Has the POWER LED turned on?
Yes: Go to step 9.
No: Set the main switch to off; set the AC power unit switch to off.
8. Call your maintenance engineer. Go to step 10.
9. Has the READY LED turned on?
Yes: Continue to use the equipment as it is.
No: Refer to section 8.1.3.
10. End of the procedure
When the POWER LED has turned off, follow these steps:
1. Electricity is received by the equipment?
Yes: Go to step 2.
No: Verify that the AC cable is correctly connected to the plug socket. Go to step 2.
2. Set the main switch to off, then set the AC power unit switch to off.
3. After waiting for more than one minute, set the AC power unit switch to on, then set the
main switch to on.
4. Has the POWER LED turned on?
Yes: Go to step 6.
No: Set the main switch to off, then set the AC power unit switch to off.
5. Call your maintenance engineer.
8.1.3 READY LED does not Turn On or the READY LED has Turned On Once, then Turned Off
If the READY LED does not turn on or the READY LED has turned on once, then turned off,
follow these steps:
1. Is the POWER LED on?
Yes: Go to step 2.
No: Go to step 4 in POWER LED does not turn on.
2. Is the ALARM LED on?
Yes: Refer to ALARM LED has turn on.
No: Go to step 3.
3. Turn off the main switch.
4. After waiting for more than one minute, set the AC power unit switch to on, then set the
main switch to on.
5. Has the READY LED turned on?
Yes: Continue to use the equipment as it is. Go to step 8.
No: Go to step 6.
6. Set the main switch to off, then set the AC power unit switch to off.
7. Call your maintenance engineer.
8. End of the procedure
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 137
8.1.4 The Alarm LED has Turned On
When the ALARM LED has turned on, follow these steps:
1. Identify the components in which the failure is resident.
Note: Refer to section 4.7.5 to identify failed components whose LEDs indicate their
respective failures.
2. Set the main switch to off, then set the AC power unit switch to off.
3. Call your maintenance engineer.
When the WARNING LED has turned on or blinks, follow these steps:
1. Does the WARNING LED blink?
Yes: Call your maintenance engineer. Go to step 5.
No: Go to step 2.
2. Is the READY LED on?
Yes: Go to step 3.
No: Refer to section 8.1.3.
3. Identify the components in which a failure is resident.
Note: Refer to section 4.7.5 to identify failed components whose LEDs indicate their
respective failures.
4. Continue to use the equipment and contact the maintenance engineer.
5. End of the procedure
The Web operational environment and the necessary requirements are shown in the
following tables.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 139
Table 8.2 Web Operational Requirements
Network Parameter
The 9580V has the following network parameters; they can be set or changed by the
Web browser or the Resource Manager 9500V, concerning only port 1 (for users) of each
controller.
Controller 0 Controller 1
Note 1: Manage the IP Address after the IP Address is changed from the IP Address of factory setting.
Note 2: When the DHCP mode is validated, the IP Address is acquired from the DHCP server.
If the DHCP server is not started up or the DHCP function has been wrongly set, the acquisition of the IP Address will fail and
the IP Address of the subsystem will remain 0.0.0.0. (This is a state in which Resource Manager 9500V or the Web cannot be
used via a LAN.)
In this case, you can acquire the IP Address by starting up the DHCP server or by setting the DHCP function correctly when
necessary.
Note 3:
Microprogram revision 0653/B or earlier
(1) When the user’s port address is set to other than 10.x.x.x, 10.x.x.x cannot be used for the IP address for LAN device to be
connected to user’s port through a gateway. Therefore, set the IP address to other than 10.x.x.x.
(2) When the user’s port address is set to 10.x.x.x, 192.168.0.x cannot be used for the IP address for LAN device to be
connected to user’s port through a gateway. Therefore, set the IP address to other than 192.168.0.x.
Microprogram revision 0653/C or later
(1) When the user’s port address is set to other than 10.x.x.x, 10.0.0.(0 to 31) cannot be used for the IP address for LAN device
to be connected to user’s port through a gateway. Therefore, set the IP address to other than 10.0.0.(0 to 31).
(2) When the user’s port address is set to 10.x.x.x, 192.168.0.(0 to 31) cannot be used for the IP address for LAN device to be
connected to user’s port through a gateway. Therefore, set the IP address to other than 192.168.0.(0 to 31).
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 141
8.3 Web Operational Procedures
This section contains the following information:
Connecting to the Network using a LAN Interface
Screen Outlines
Main Screen in Normal Mode
Status Display of Replaceable Components
Information Message
Setting the Buzzer Sound Volume
2. Connect the LAN cable with the LAN connector shown in the Figure 8.1.
LAN Connector
Change the IP Address of the controller set up to the Address of the Web browser, to enter
Normal Mode. Set the IP Address of the controller connected with the network as a dual
system configuration. The status of the devices (both controllers) can be monitored from
one controller.
If the function is displayed and clicked in the menu screen, the chosen function can be
executed. The following figure displays the main screen outline of Normal Mode.
Version frame
Menu Frame
Main Frame
Version Frame
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 143
8.3.2.1 Menu Frame
Information Message: Fault information, detected during device operation and device
information status is displayed.
Note: When the PC enters suspension status during operation while the Page Refresh
Mode is set to ON, the Web may not operate correctly after the PC is released from
suspension status. When the Web is connected for status monitoring, etc., set the power
management of the PC so that the PC does not enter suspension status.
Subsystem Status: The device status and the exchange parts status are displayed.
Progress Condition: The Progress Condition as the device is booting is displayed.
Web title: The Web title set by a user is displayed. When it is not set, nothing is
displayed.
Patrol lamp
Summary of exchange
parts status
Progress condition
display
Image Status
Normal
blue
Warning status
yellow
Alarm status
red
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 145
8.3.3.2 Summary of Exchange Parts Status
The summary of exchange parts status displays the condition of the exchange parts by
changing the color. Detailed information of the specific part is displayed by clicking the part
icon.
Parts Image
Normal Abnormal
Power Unit
blue red
Disk Drive
blue red
Cache Unit
green red
Fan Assembly
black red
Control Unit
green red
ENC Unit
green red
Fibre Loop
blue red
Note: A path blockage that occurred while using the Hitachi TrueCopy function (even if the remote subsystem was off) also
occurs. The remote subsystem is turned on and automatically recovered when the remote subsystem is Ready. If a path
blockage is not recovered (even when Ready), contact Hitachi Customer Service.
The progress condition, as the device is booting, is displayed in the progress condition
display box.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 147
8.3.4 Status Display of Replaceable Components
The status display screen of replaceable components is displayed by clicking the Disk Drive,
CTL/Cache/Loop/Battery, or AC/ENC/Fan on the menu frame in the main window. The
status display screen of replaceable components displays the status of the Disk Drive,
Control Unit, Cache Unit, Fiber Channel Loop, Fan Assembly, Backup Battery Unit, Power
Unit/Power Unit (DC), and ENC Unit that are implemented.
This image is not displayed if the component is not implemented. When the replaceable
component has an abnormal status, a red image is displayed.
Normal
blue
red
The disk drive port where the fault occurred is not implementing
the disk drive.
red and black
No display The disk drive is not implemented (the disk drive where the fault
occurred was drawn out).
Control Unit
Image Status
Normal
green
No display The fault has not occurred without being implemented with the
setting of a single system configuration.
Cache Unit
Image Status
Normal
green
Fault
(status when the unit is not implemented and the extracted fault
red cache unit is included)
Normal
blue
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 149
Fan Assembly
Image Status
Normal
black
Normal
blue
ENC Unit
Image Status
Normal
green
Fibre Loop
Image Status
Normal
blue
Fault
red
Fault information and status information of the device that detected it during the device
operation are displayed.
Fault information and status information after the device completes a boot are displayed in
the Controller 0/1 Common box.
Fault information and status information as the device is booting are displayed in the box of
Controller 0 and Controller 1 for every the controller.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 151
8.3.6 Setting the Buzzer Sound Volume
Note: Set the buzzer volume for the environment in which I/Os from a host are not issued
while the system is maintained or before the host is started up.
The buzzer volume can be adjusted for 5 stages. Click the Buzzer Volume of the menu
frame to enter into the buzzer volume-setting screen. If the buzzer volume is designated
with the radio button and the OK button is clicked, the buzzer volume is changed.
Check the position of the failed part of the unit on the main window in the normal mode of
the Web.
Subsystem Status
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 153
8.4.2 Checking the Progress Condition Display
If Booting... is indicated in the window (the controller is being started up), the progress of
the start-up operation can be confirmed according to the following procedure:
1. Turn on the page refresh mode (click the ON button).
2. The window is updated automatically at 5-second intervals. (If the OFF button of the
page refresh mode is activated, this operation is not necessary.)
3. If the page refresh mode is not activated in the main window, press the update button
of the browser to update the window.
4. Observe the condition-in-progress within the window.
Progress Condition
display
Click each part of Replace Part Summary in the main window; the following window appears
and the state of the part is displayed.
In this example, the selected (clicked) part is at the head of the window. You can also select
this window by clicking Disk Drive, CTL/Cache/Loop/Battery, or AC/ENC/Fan on the menu
in the main window. If a part fails, its corresponding icon turns red.
The following screen is displayed only when the icon of a remote path is clicked. This screen
is displayed only when the Synchronous TrueCopy function is effective.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 155
8.4.4 Checking Log Messages
4. The information on the detected failures during operation of the unit and the state of
the unit are displayed in the upper part of the window.
5. The information on the failures and the state at the start-up time of the unit is displayed
for each Controller in the Controller 0 and Controller 1 boxes.
Example:
MM/DD/YYY HH:MM:SS Cx 54
MM/DD/YYY HH:MM:SS Cx 50
MM/DD/YYY HH:MM:SS Cx 4C
MM/DD/YYY HH:MM:SS Cx 48
MM/DD/YYY HH:MM:SS Cx 44
MM/DD/YYY HH:MM:SS Cx 40
MM/DD/YYY HH:MM:SS Cx 3C
MM/DD/YYY HH:MM:SS Cx 38
MM/DD/YYY HH:MM:SS Cx 34
MM/DD/YYY HH:MM:SS Cx 30
MM/DD/YYY HH:MM:SS Cx 2C
MM/DD/YYY HH:MM:SS Cx 28
MM/DD/YYY HH:MM:SS Cx 24
MM/DD/YYY HH:MM:SS Cx 20 zzzzzzzz
MM/DD/YYY HH:MM:SS Cx {{{{{{{{{{{{
MM/DD/YYY HH:MM:SS Cx CTLx
MM/DD/YYYY: Data of occurrence
HH:MM:SS: Time of occurrence
Cx: # of Controller in which failure is detected
: PCI Config information
: Detailed information
zzzzzzzz: Message code
{{{{{{{{{{{{: Message text (Any number of letters)
CTLx: CUDG executing controller #
Note: The date and time the RTC is set in the detection controller is displayed in this
message. If the RTC is different from one control to another, the displayed time of
occurrence may differ within messages. Therefore, the latest message may be indicated
on the top line.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 157
In this example, the latest message is also indicated at the top.
Example:
MM/DD/YYY HH:MM:SS Cx zzzzzz {{{{{{{{{{{ : /
MM/DD/YYY HH:MM:SS Cx zzzzzz {{{{{{{{{{{ : /
:
:
The contents of each failure detected during operation are reported by a message. The
failures detected during operation and the state of the unit, after the main switch of this
unit is turned on, are reported.
The five types of message codes are displayed in the following table:
When the Errors detected by CUDG are displayed, call your maintenance personnel.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 159
8.4.5.2 Flash Detected Messages
When the following Flash detected messages are displayed, follow the instructions to resolve
the problem.
RB0000 Upload system error Check the microprogram you want to install and install it
over again.
RB0A00 Upload file SUM check error A sum check error occurred in a read file during a upload.
Check the microprogram you want to install and install it
over again.
RB0E00 Up grade check NG The upgrade check of the microprogram failed. (An
upgrade version of a microprogram does not conform to
the microprogram being upgraded.) Do a new install of the
microprogram.
RB3000 File size error Check the microprogram you wish to install.
RB8000 Old microprogram exists If the installation can be continued, the RAID group and
LU deformation are initialized. (In this case, all the data in
the disk drive are deleted. When the data in the disk drive
need to be saved, stop the work and perform the update
installation.
RB8300 Empty system retry full install The update installation cannot be executed because a
system does not exist in the disk drive.
Execute a new installation.
RBA000 Down grade check NG The present microprogram version cannot be updated to a
specified microprogram version.
Check the work procedure.
Execute a new installation.
When a Flash detected message other than those shown above is displayed, inform
maintenance personnel of the message code.
When the following Progress messages are displayed, follow the instructions to resolve the
problem.
I11000 All raid group initialized All RAID groups were deleted.
I111xx RAID group deleted (RG-xx) RAID group was deleted. (xx: RAID group# [0-89])
I12000 ALL LU initialized All LUs were deleted. (This is also displayed when the
LU#0 is created.)
I12200 LU format completed (LU-xxx) LU formatting was completed. (xxx: LU# [0-2047])
I12400 LU format start (LU-xxx) An LU formatting was started. (xxx: LU# [0-2047])
I12500 Unified LUs separated (Uni: LU-xxx) Dissolution of all LU unification (to dissolve unification of
all the unified LUs and to split them into internal LUs) was
executed.
(xxx: LU# [0 to 2047] of a unified LU to be split)
I12600 Last LU separated from unified LU A separation of a final LU of a unified LU (to separate the
(Uni: LU-xxx) last one of the internal LUs which have been combined
with a unified LU) was executed.
(xxx: LU# [0 to 2047] of a unified LU to be split)
I12700 LU reappeared (Uni: LU-xxx) An internal LU(s) was validated again through splitting of
all unified LUs or separation of a final LU.
(xxx: An LU# [0 to 2047] of an internal LU which has been
separated and validated)
I17002 Default LU-CTL change failed [PS Set the equipment in the ready state and turn off the
OFF] power, then turn on the power again.
I17003 Default LU-CTL change failed [HOT] Use the system as it is.
I1A00x Permanent LU disable Set the equipment in the ready state and turn off the
(Default CTL-x) power, then turn on the power again
I1A30x Turbo-LU enable (Default CTL-x) The FlashAccess function was turned on.
(x: Default Controller# [0 or 1])
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 161
Table 8.6 Progress Messages (continued)
I1B100 Forced parity correction completed Forced parity recovery processing was finished.
Note: When a Progress message other than those shown above is displayed, inform maintenance personnel of the message
code.
When the following Warning messages are displayed, follow the instructions to resolve the
problem.
Note: When a Progress message other than those shown above is displayed, inform maintenance personnel of the message
code.
When the following Failure messages are displayed, follow the instructions and resolve the
problem.
H90330 Connection unit excess The number of connected units exceeded the limit.
Note: When a Progress message other than those shown above is displayed, inform maintenance personnel of the message
code.
1 Controller error/ recover W0100x: CTL alarm (CTL-x) I0010x: CTL recovered (CTL-x)
2 error/recovery W0D0x0: Cache alarm (CTL-y, CACHE-z) I0020z: Cache recovered (CACHE-z)
4 Battery backup board W0340x: Battery backup circuit alarm I0040x: Battery backup circuit recovered
error/recovery (CTL-x) (CTL-x)
5 Fan error/recovery W04100: FAN alarm (Unit-x, FAN-y) I00500: FAN recovered (Unit-xx, FAN-y)
W042HH: FAN alarm (Unit-x, FAN-y) I005HH: FAN recovered (CTL-x, FAN-y)
6 Power supply error/ W05100: PS alarm (Unit-x, PS-y) I00600: PS recovered (CTL-Unit, PS-y)
recovery
W052HH: PS alarm (Unit-x, PS-y) I006HH: PS recovered (Unit-x, PS-y)
7 Disk drive error/ recovery W060HH: HDU alarm (Unit-x, HDU-y) I007HH: HDU recovered (Unit-x, HDU-y)
8 Spare disk error/ recovery W061HH: Spare HDU alarm I009HH: Spare HDU recovered
(Unit-x, HDU-y) (Unit-x, HDU-y)
9 Loop error/recovery W080xy: Loop alarm (Path-x, Loop-y) I00Axy: Loop recovered
(Path-x, Loop-y)
10 ENC board error/ recovery W090HH: ENC alarm (Unit-x, ENC-y) I00BHH: ENC recovered
(Path-x, Loop-y)
11 UPS error/recovery W0C00x: UPS alarm (UPS-x) I00D0x: UPS recovered (UPS-x)
12 Path error/recovery W0F0xy: Path alarm (Remote-x, Path-y) I030xy: Path recovered by web operation
(Remote-x, Path-y)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 163
07/02/2000 08:02:34 C0 W06011 HDU alarm(Unit-1,HDU-1) :HDU /TRC
Messages which
07/01/2000 23:55:35 C1 W01000 CTL alarm(CTL-0) :CTL /DMP require maintenance
07/01/2000 23:55:34 C1 H90210 CTL failure :CTL /DMP
Recovery completed
06/29/2000 20:18:23 C1 I00724 HDU recovered(Unit-2,HDU-4)
Recovery
06/29/2000 20:15:10 C0 I00610 PS recovered(Unit-1,PS-0) completed
06/29/2000 19:30:23 C1 W06024 HDU alarm(Unit-2,HDU-4) :HDU /TRC
06/29/2000 19:30:23 C1 I00824 Spare HDU recovered(Unit-2,HDU-4) Messages indicated
with regard to Disk
06/29/2000 19:30:23 C1 I15102 Data recovery completed(Unit-0,HDU-2)
drive alarm (These
06/29/2000 19:26:33 C1 I15002 Data recovery started(Unit-0,HDU-2) do not require
06/29/2000 19:26:33 C1 I15A24 Dynamic sparing start(Unit-2,HDU-4) maintenance.)
06/29/2000 19:26:33 C1 I51024 D_PT error(HDU Unit-2,HDU-4)
Messages after
06/29/2000 18:32:06 C0 W05010 PS alarm(Unit-1,PS-0) :PS the unit is ready
06/15/2000 09:45:31 C0 I00100 CTL recovered(CTL-0) Recovery
completed
06/15/2000 08:30:08 C1 I10000 Subsystem is Ready
06/15/2000 08:29:25 C1 W01000 CTL alarm(CTL-0) :CTL /DMP
Messages before
the unit is ready
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 165
166 Chapter 9 Periodic Maintenance
Appendix A Glossary
Cache backup
Because a cache memory uses DRAM, information stored in it is lost when the subsystem
power is shut off. To provide against unexpected power failure, the subsystem has an
setup to maintain data in the cache memory by batteries.
Cache backup is a state in which the data is protected by the batteries.
CTL
Controller
CUDG
Control Unit Diagnosis
Destage
Automatically writes data in cache memory, not yet written on the disk drive, on the
disk drive when the main switch is turned off.
DHCP
DHCP is an abbreviation for Dynamic Host Configuration Protocol; it is a client/server
type protocol according to which a server automatically assigns an IP address when each
client has started.
ECC
Error Checking and Correcting
EIA
Electronic Industries Alliance
EIA standard (1 EIA unit = 44.45 mm)
FC-AL
Fibre Channel Arbitrated Loop
FC-SW
Fibre Channel-Switch Topology
Fibre channel
A set of standards of interfaces that are connected through optical fibre, etc. to achieve
high-speed data transfer between devices.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 167
Flash memory
ROM that can be electrically erased and reprogrammed. A type of EEPROM (Electrically
Erasable and Programmable). It can retain information without electricity and is widely
used as an external storage, etc.
Host computer
A computer which manages devices. For the disk array, it is a computer which enables
the disk array store data.
Hot replacement
Used to replace an installed part with the subsystem power on. Usually, the major part
is duplicated so that when one of the parts fails, the subsystem function is maintained
by another part.
I/F
Interface
IP address
IP address is an abbreviation for Internet Protocol Address; it is a numeral string which
shows an address of a computer connected to a network.
LA
Logical Address
LBA
Logical Block Address
LED
Light-Emitting Diode
LRC
Longitudinal Redundancy Check
LSI
Large-service Interface
LU
Logical Unit
LVD
Low Voltage Differential
Microprogram
A program that controls the basic hardware operation.
PDB
Power Distribution Box
Rack frame
A frame on which electronic equipment is mounted (using rails, etc.). Most rack frames
have a width of 19 inches and are called 19-inch rack frames. The height of the
equipment to be mounted is regulated by the EIA standard. The rack frame has screw
holes to fasten equipment with bolts, etc.
RAID
Redundant Array of Independent (Inexpensive) Disks
A concept proposed in 1987 by a research group of the University of California, Berkeley.
RAID distributes accesses among multiple disk drives, and thereby realizes a storage
subsystem with high-speed accessibility, a large capacity, and high reliability.
The University of California defined six levels of configurations from RAID 0 through RAID
5, and one of the levels is selected based on the trade-off in terms of cost and speed to
meet the user’s need.
R/W
Read/Write
SNMP
SNMP is an abbreviation for Simple Network Management Protocol, and it is one of the
network protocols developed to manage a network.
Spare disk
A disk drive which is mounted separately from the disk drives for usual write and read
operation; when a failure occurs in a disk drive, data stored in the failed drive is copied
to the spare disk drive so that the disk subsystem can continue to be available
equivalently to the original subsystem.
UPS
Uninterrupted Power Supply
A backup power supply which is mounted on the Thunder 9580 unit to prevent shutdown
of the unit even when power stoppage or momentary power interruption occurs.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 169
Write cache
When data is written from a host computer onto a disk array subsystem, it is not written
directly on the disk drive but written in cache memory. In this way, the disk array
subsystem can return a writing completion report promptly. This writing method using
cache memory is called write cache.
System Parameter
1 System Startup Attribute Depends on System Configuration (Note 1)
2 Data Share Mode Depends on System Configuration (Note 2)
3 Drive Detach mode enable Disable (Standard setting)
4 Report status (normal/warning) Enable (Standard setting)
5 Turbo LU Warning Disable (Standard setting)
6 Operation if the Processor failures Occurs Reset a Fault (Standard setting)
7 Command Queuing Mode On (Standard setting)
8 ROM Microprogram Version No change is needed
9 RAM Microprogram Version No change is needed
10 RS232C Error Information Outflow Mode When RS232C is used: On
When RS232C is not used: Off (Standard setting)
11Write & Verify Executing Mode On (Standard setting)
12DHCP (Note 4) OFF (Standard setting)
13IP Address To be set according to the network setting
14Subnet Mask To be set according to the network setting
15Default Gateway To be set according to the network setting
Host Group
1 LU Mapping Mode Depends on System Configuration (Note 3)
Note 1: Hot Standby mode is used when only one of the two Controllers is normal.
Note 2: Data Share mode is used to prevent performance deterioration which results from LU ownership that is switched when a host computer
issues commands frequently to a Controller to which the computer has no ownership, in the normal or regression status (owing to a path or
host computer failure).
It is recommended that the subsystem in the Data Share mode be used when LU ownership switching may occur.
Note 3: When the 9580V is connected, the LU not intended to be accessed by the port must be masked by means of LU mapping mode.
Note 4: When the DHCP mode is validated, the IP Address is acquired from the DHCP server.
If the DHCP server is not started or the DHCP function has been incorrectly set, the acquisition of the IP Address will fail and the IP Address of
the subsystem will remain “0.0.0.0”. (When this occurs, the Resource Manager 9500V program or the Web cannot be used via a LAN.) In this
case, acquire the IP Address by starting the DHCP server or by setting the DHCP function correctly when necessary.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 171
Table B.2 Host Connection Parameters (continues on the following pages)
Simple Setting
1 Platforms HP-UX Solaris
Configuration Information
Port Option
1 LIP Reset Mode OFF OFF
2 Read Frame Min 128 Byte OFF OFF
Mode (Note7)
Unit Identifier
3 Controller Identifier Disable Enable Enable
4 Controller ID --- DF600-00 (Note6) DF600-00 (Note6)
(Standard Setting) (Standard Setting)
System Parameter
INQUIRY Setting
1 Vendor ID HITACHI (Standard Setting) HITACHI (Standard Setting)
2 Product ID DF600F (Standard Setting) DF600F (Standard Setting)
Note: When making the simple setting of the host group options, select items shown on gray backgrounds.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 173
Table B.2 Host Connection Parameters (continued)
Simple Setting
1 Platforms AIX NT/Windows2000/2003
Configuration Information
Port Option
1 LIP Reset Mode OFF OFF ON OFF
2 Read Frame Min 128 Byte OFF OFF
Mode
Unit Identifier
3 Controller Identifier Disable Disable Enable
4 Controller ID --- --- DF600-00 (Note5)
(Standard Setting)
System Parameter
INQUIRY Setting
1 Vendor ID HITACHI (Standard Setting) HITACHI (Standard Setting)
2 Product ID DF600F (Standard Setting) DF600F (Standard Setting) DF500F
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 175
Table B.2 Host Connection Parameters (continued)
Simple Setting
1 Platforms Linux Tru64 Others
Configuration Information
Port Options
1 LIP Reset Mode OFF OFF OFF
2 Read Frame Min 128 Byte OFF OFF OFF
Mode
Unit Identifier
3 Controller Identifier Disable Enable Disable Disable
4 Controller ID --- DF600-00 (Note2) --- ---
(Standard Setting)
System Parameter
INQUIRY Setting
1 Vendor ID HITACHI (Standard Setting) HITACHI (Standard Setting) HITACHI (Standard Setting)
2 Product ID DF600F DF500F DF600F(Standard Setting) DF600F(Standard Setting)
(Standard
Setting)
Note: When making the simple setting of the host group options, select items shown on gray backgrounds.
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 177
178 Appendix B System Parameter Setting List
Appendix C Basic Specifications of the 9580V Subsystem
This appendix includes the following:
Basic Specifications
Table C.1 Basic Specifications of 9580V for RDH (continues on the following page)
RKH RKA
Subsystem appearance
Note 1: For additional information about the rack-mount model, refer to the Hitachi Freedom Storage™ Thunder 9500™ V
Series 19-Inch Rack Reference Guide (MK-92DF654).
Note 2: For additional information about the global rack-mount model, refer to the Hitachi Data Systems Global 19-Inch Rack
Reference Guide (MK-92DF665).
Note 3: This value of storage capacity is calculated as 1 Gbyte = 1,000,000,000 bytes. (This definition is different from
1 Kbyte = 1,024 bytes.)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 179
Table C.1 Basic Specifications of 9580V for RKH (continued)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 181
Table C.1 Basic Specifications of 9580V (continued)
RKH RKA
Maintenance Spare disk Up to fifteen of mounted Disk drives can be set to Spare disks
specifications/
antifault Display function Status LEDs (POWER, READY, WARNING, and ALARM),
specifications LED of maintenance part
Note 1: Non-volatility of data in the cache memory is ensured against power trouble such as a sudden power failure. It transfers
data in the Cache memory to Disk drives by turning off the power normally, and prevents the battery charge from being wasted.
When the subsystem enters the Cache Backup mode, a warning (lighting of the orange LED) informing of a voltage drop of the
battery may be issued when the subsystem is started. It shows that the remaining capacity of the battery is not sufficient, and in
this state, the subsystem operates disabling the Write Cache function automatically, when the voltage of two batteries drops.
When the battery is charged, the warning indication disappears, and the subsystem continues the operation enabling the Write
Cache function. The warning indication disappears within 2 hours at the latest. Even when the warning is indicated, normal
functional operation is assured although the operation is performed in the Write-Through mode and the R/W performance is
lowered because the Write Cache function is disabled.
Since the battery is subject to the effect of the environmental temperature, avoid using a battery in unnecessarily continuous
operation at a high temperature.
If the subsystem is not energized for more than30 days( when two batteries are installed), the battery over-charges and this can
result in unrecoverable damage. The battery must be energized more than 2 hours at least once every 30 days (when two
batteries are installed), or the subsystem should be stored with the switch of the battery turned off. Even when the switch is
turned off, the battery discharges naturally. In this case, charge the battery once per six months for longer than 2 hours.
Note: All values of storage capacities in the following tables are calculated as
1 Gbyte = 1,000,000,000 bytes.
Table D.1 List of Capacities Corresponding to RAID 0 (36 Gbytes) (continues on the following page)
35.4 G bytes
Disk capacity
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
63.2 472.5 967.5 1533.2 2028.2 2593.9 3088.9 3654.6 4149.6 4715.3 5210.3 5776.0 6271.0 6836.7 7331.7 7897.4
3D 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
94.8 401.8 932.1 1462.5 1992.8 2523.2 3053.5 3583.9 4114.2 4644.6 5174.9 5705.3 6235.7 6766.0 7296.4 7826.7
4D 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
126.4 394.2 960.0 1525.7 1950.0 2515.7 3081.4 3647.1 4071.4 4637.1 5202.8 5768.5 6192.8 6758.5 7324.2 7889.9
5D 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
158.0 334.8 865.2 1395.5 1925.9 2456.2 2986.6 3516.9 4047.3 4577.6 5108.0 5638.3 6168.7 6699.1 7229.4 7759.8
6D 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
189.6 401.8 826.0 1462.5 1886.7 2523.2 2947.5 3583.9 4008.2 4644.6 5068.9 5705.3 6129.6 6766.0 7190.3 7826.7
7D 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
221.2 468.7 963.7 1458.7 1953.7 2448.7 2943.7 3438.7 4181.2 4676.2 5171.2 5666.2 6161.2 6656.2 7151.2 7893.7
8D 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
252.8 252.8 818.5 1384.2 1950.0 2515.7 3081.4 3647.1 3929.9 4495.7 5061.4 5627.1 6192.8 6758.5 7324.2 7889.9
9D 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
284.4 284.4 920.8 1239.1 1875.5 2511.9 2830.1 3466.5 4103.0 4421.2 5057.6 5694.0 6012.3 6648.7 7285.1 7603.3
10D 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
316.0 316.0 669.6 1376.7 1730.3 2437.4 2791.0 3498.2 3851.7 4558.9 4912.4 5619.6 5973.1 6680.3 7033.9 7741.0
11D 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
347.6 347.6 736.5 1514.4 1903.3 2292.3 3070.1 3459.0 3848.0 4625.8 5014.7 5403.7 6181.5 6570.5 7348.3 7737.2
12D 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
379.2 379.2 803.5 1227.8 1652.1 2500.6 2924.9 3349.2 3773.5 4622.1 5046.3 5470.6 5894.9 6743.5 7167.8 7592.1
13D 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
410.8 410.8 870.5 1330.1 1789.7 2249.4 2709.0 3628.3 4088.0 4547.6 5007.2 5466.9 5926.5 6386.2 7305.4 7765.1
14D 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
442.4 442.4 937.4 1432.4 1927.4 2422.4 2917.4 3412.4 3907.4 4402.4 4897.4 5392.4 5887.4 6382.4 6877.4 7867.4
15D - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 474.0 1004.4 1534.7 2065.1 2595.5 3125.8 3656.2 4186.5 4716.9 5247.2 5777.6 6307.9 6838.3 7368.6
16D - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 505.6 1071.3 1637.1 2202.8 2768.5 3334.2 3899.9 4465.6 5031.3 5597.0 6162.8 6728.5 7294.2 7859.9
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 183
Table D.1 List of Capacities Corresponding to RAID 0 (36 Gbytes) (continued)
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
8392.4 8958.1 9453.1 10018.9 10513.9 11079.6 11574.6 12140.3 12635.3 13201.0 13696.0 14261.7 14756.7 15322.4 15817.4
3D 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
8357.1 8887.4 9417.8 9948.1 10478.5 11008.9 11539.2 12069.6 12599.9 13130.3 13660.6 14191.0 14721.3 15251.7 15782.0
4D 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
8314.2 8879.9 9445.6 10011.3 10435.6 11001.3 11567.1 12132.8 12557.1 13122.8 13688.5 14254.2 14678.5 15244.2 15809.9
5D 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
8290.1 8820.5 9350.8 9881.2 10411.5 10941.9 11472.3 12002.6 12533.0 13063.3 13593.7 14124.0 14654.4 15184.7 15715.1
6D 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
8251.0 8887.4 9311.7 9948.1 10372.4 11008.9 11433.1 12069.6 12493.8 13130.3 13554.6 14191.0 14615.3 15251.7 15676.0
7D 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
8388.7 8883.7 9378.7 9873.7 10368.7 10863.7 11606.2 12101.2 12596.2 13091.2 13586.2 14081.2 14576.2 15318.7 15813.7
8D 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
8172.8 8738.5 9304.2 9869.9 10435.6 11001.3 11567.1 12132.8 12415.6 12981.3 13547.0 14112.8 14678.5 15244.2 15809.9
9D 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
8239.7 8876.2 9194.4 9830.8 10467.2 10785.4 11421.9 12058.3 12376.5 13012.9 13649.4 13967.6 14604.0 15240.4 15558.6
10D 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
8094.6 8801.7 9155.3 9862.4 10216.0 10923.1 11276.7 11983.8 12337.4 13044.5 13398.1 14105.3 14458.8 15166.0 15519.5
11D 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
8126.2 8904.0 9292.9 9681.9 10459.7 10848.7 11237.6 12015.4 12404.4 13182.2 13571.1 13960.1 14737.9 15126.8 15515.8
12D 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
8016.3 8864.9 9289.2 9713.5 10137.8 10986.3 11410.6 11834.9 12259.2 13107.7 13532.0 13956.3 14380.6 15229.2 15653.4
13D 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
8224.7 8684.4 9144.0 9603.6 10522.9 10982.6 11442.2 11901.9 12361.5 12821.1 13280.8 14200.1 14659.7 15119.3 15579.0
14D 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
8362.4 8857.4 9352.4 9847.4 10342.4 10837.4 11332.4 11827.4 12322.4 12817.4 13312.4 13807.4 14302.4 15292.4 15787.4
15D 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
7899.0 8429.4 8959.7 9490.1 10020.4 10550.8 11081.1 11611.5 12141.8 12672.2 13202.6 13732.9 14263.3 14793.6 15324.0
16D 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
7859.9 8425.6 8991.3 9557.0 10122.7 10688.4 11254.2 11819.9 12385.6 12951.3 13517.0 14082.7 14648.4 15214.1 15779.9
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
1D+1P 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
31.6 236.2 483.7 766.6 1014.1 1296.9 1544.4 1827.3 2074.8 2357.7 2605.2 2888.0 3135.5 3418.4 3665.9 3948.7
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
1D+1P 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
4196.2 4479.1 4726.6 5009.4 5256.9 5539.8 5787.3 6070.1 6317.6 6600.5 6848.0 7130.8 7378.3 7661.2 7908.7
184 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Table D.3 List of Capacities Corresponding to RAID 5 (36 Gbytes)
Disk capacity 35.4 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+1P 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
63.2 267.8 621.4 975.0 1328.5 1682.1 2035.7 2389.3 2742.8 3096.4 3450.0 3803.5 4157.1 4510.7 4864.2 5217.8
3D+1P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
94.8 295.7 720.0 1144.3 1462.5 1886.7 2311.0 2735.3 3053.5 3477.8 3902.1 4326.4 4644.6 5068.9 5493.2 5917.4
4D+1P 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
126.4 267.8 692.1 1116.4 1540.7 1965.0 2389.3 2813.5 3237.8 3662.1 4086.4 4510.7 4935.0 5359.2 5783.5 6207.8
5D+1P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
158.0 334.8 688.4 1218.7 1572.3 2102.6 2456.2 2986.6 3340.1 3870.5 4224.1 4754.4 5108.0 5638.3 5991.9 6522.3
6D+1P 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
189.6 401.8 826.0 1250.3 1674.6 2098.9 2523.2 2947.5 3583.9 4008.2 4432.5 4856.7 5281.0 5705.3 6129.6 6766.0
7D+1P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
221.2 221.2 716.2 1211.2 1706.2 2201.2 2696.2 3191.2 3438.7 3933.7 4428.7 4923.7 5418.7 5913.7 6408.7 6903.7
8D+1P 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
252.8 252.8 818.5 1101.4 1667.1 2232.8 2515.7 3081.4 3647.1 3929.9 4495.7 5061.4 5344.2 5909.9 6475.6 6758.5
9D+1P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
284.4 284.4 602.6 1239.1 1557.3 2193.7 2511.9 3148.3 3466.5 4103.0 4421.2 5057.6 5375.8 6012.3 6330.5 6966.9
10D+1P 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
316.0 316.0 669.6 1376.7 1730.3 2083.9 2791.0 3144.6 3498.2 4205.3 4558.9 4912.4 5619.6 5973.1 6680.3 7033.9
11D+1P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
347.6 347.6 736.5 1125.5 1514.4 2292.3 2681.2 3070.1 3459.0 4236.9 4625.8 5014.7 5403.7 6181.5 6570.5 6959.4
12D+1P 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
379.2 379.2 803.5 1227.8 1652.1 2076.4 2500.6 3349.2 3773.5 4197.8 4622.1 5046.3 5470.6 5894.9 6743.5 7167.8
13D+1P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
410.8 410.8 870.5 1330.1 1789.7 2249.4 2709.0 3168.7 3628.3 4088.0 4547.6 5007.2 5466.9 5926.5 6386.2 7305.4
14D+1P - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 442.4 937.4 1432.4 1927.4 2422.4 2917.4 3412.4 3907.4 4402.4 4897.4 5392.4 5887.4 6382.4 6877.4
15D+1P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 474.0 1004.4 1534.7 2065.1 2595.5 3125.8 3656.2 4186.5 4716.9 5247.2 5777.6 6307.9 6838.3 7368.6
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+1P 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
5571.4 5925.0 6278.5 6632.1 6985.7 7339.2 7692.8 8046.4 8399.9 8753.5 9107.1 9460.7 9814.2 10167.8 10521.4
3D+1P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
6235.7 6659.9 7084.2 7508.5 7826.7 8251.0 8675.3 9099.6 9417.8 9842.1 10266.4 10690.6 11008.9 11433.1 11857.4
4D+1P 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
6632.1 7056.4 7480.7 7904.9 8329.2 8753.5 9177.8 9602.1 10026.4 10450.7 10874.9 11299.2 11723.5 12147.8 12572.1
5D+1P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
6875.8 7406.2 7759.8 8290.1 8643.7 9174.0 9527.6 10058.0 10411.5 10941.9 11295.5 11825.8 12179.4 12709.7 13063.3
6D+1P 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
7190.3 7614.6 8038.9 8463.2 8887.4 9311.7 9948.1 10372.4 10796.7 11221.0 11645.3 12069.6 12493.8 13130.3 13554.6
7D+1P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
7151.2 7646.2 8141.2 8636.2 9131.2 9626.2 10121.2 10616.2 10863.7 11358.7 11853.7 12348.7 12843.7 13338.7 13833.7
8D+1P 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
7324.2 7889.9 8172.8 8738.5 9304.2 9587.1 10152.8 10718.5 11001.3 11567.1 12132.8 12415.6 12981.3 13547.0 13829.9
9D+1P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
7285.1 7921.5 8239.7 8876.2 9194.4 9830.8 10149.0 10785.4 11103.7 11740.1 12058.3 12694.7 13012.9 13649.4 13967.6
10D+1P 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
7387.4 8094.6 8448.1 8801.7 9508.8 9862.4 10216.0 10923.1 11276.7 11983.8 12337.4 12691.0 13398.1 13751.7 14105.3
11D+1P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
7348.3 8126.2 8515.1 8904.0 9292.9 10070.8 10459.7 10848.7 11237.6 12015.4 12404.4 12793.3 13182.2 13960.1 14349.0
12D+1P 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
7592.1 8016.3 8440.6 8864.9 9713.5 10137.8 10562.0 10986.3 11410.6 11834.9 12259.2 13107.7 13532.0 13956.3 14380.6
13D+1P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
7765.1 8224.7 8684.4 9144.0 9603.6 10063.3 10522.9 10982.6 11442.2 11901.9 12361.5 12821.1 13280.8 14200.1 14659.7
14D+1P 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
7372.4 7867.4 8362.4 8857.4 9352.4 9847.4 10342.4 10837.4 11332.4 11827.4 12322.4 12817.4 13312.4 13807.4 14302.4
15D+1P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
7368.6 7899.0 8429.4 8959.7 9490.1 10020.4 10550.8 11081.1 11611.5 12141.8 12672.2 13202.6 13732.9 14263.3 14793.6
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 185
Table D.4 List of Capacities Corresponding to RAID 1+0 (36 Gbytes)
Disk capacity 35.4 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+2P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
63.2 197.1 480.0 762.8 975.0 1257.8 1540.7 1823.5 2035.7 2318.5 2601.4 2884.3 3096.4 3379.3 3662.1 3945.0
3D+3P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
94.8 200.9 413.0 731.2 943.4 1261.6 1473.7 1791.9 2004.1 2322.3 2534.4 2852.7 3064.8 3383.0 3595.1 3913.4
4D+4P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
126.4 126.4 409.3 692.1 975.0 1257.8 1540.7 1823.5 1965.0 2247.8 2530.7 2813.5 3096.4 3379.3 3662.1 3945.0
5D+5P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
161.8 158.0 334.8 688.4 865.2 1218.7 1395.5 1749.1 1925.9 2279.4 2456.2 2809.8 2986.6 3340.1 3516.9 3870.5
6D+6P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
197.1 189.6 401.8 613.9 826.0 1250.3 1462.5 1674.6 1886.7 2311.0 2523.2 2735.3 2947.5 3371.7 3583.9 3796.0
7D+7P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
232.5 221.2 468.7 716.2 963.7 1211.2 1458.7 1706.2 1953.7 2201.2 2448.7 2696.2 2943.7 3191.2 3438.7 3933.7
8D+8P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 252.8 535.7 818.5 1101.4 1384.2 1667.1 1950.0 2232.8 2515.7 2798.5 3081.4 3364.2 3647.1 3929.9
Table D.4 List of Capacities Corresponding to RAID 1+0 (36 Gbytes) (continued)
Disk capacity 35.4 G bytes
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+2P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
4157.1 4440.0 4722.8 5005.7 5217.8 5500.7 5783.5 6066.4 6278.5 6561.4 6844.2 7127.1 7339.2 7622.1 7904.9
3D+3P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
4125.5 4443.7 4655.9 4974.1 5186.2 5504.4 5716.6 6034.8 6246.9 6565.1 6777.3 7095.5 7307.6 7625.8 7838.0
4D+4P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
4086.4 4369.2 4652.1 4935.0 5217.8 5500.7 5783.5 6066.4 6207.8 6490.7 6773.5 7056.4 7339.2 7622.1 7904.9
5D+5P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
4047.3 4400.9 4577.6 4931.2 5108.0 5461.6 5638.3 5991.9 6168.7 6522.3 6699.1 7052.6 7229.4 7583.0 7759.8
6D+6P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
4008.2 4432.5 4644.6 4856.7 5068.9 5493.2 5705.3 5917.4 6129.6 6553.9 6766.0 6978.2 7190.3 7614.6 7826.7
7D+7P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
4181.2 4428.7 4676.2 4923.7 5171.2 5418.7 5666.2 5913.7 6161.2 6408.7 6656.2 6903.7 7151.2 7646.2 7893.7
8D+8P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
3929.9 4212.8 4495.7 4778.5 5061.4 5344.2 5627.1 5909.9 6192.8 6475.6 6758.5 7041.4 7324.2 7607.1 7889.9
186 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Table D.5 List of Capacities Corresponding to RAID 0 (72 Gbytes)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
135.1 975.8 1974.2 3115.2 4113.5 5254.5 6252.8 7393.8 8392.2 9533.1 10531.5 11672.5 12670.8 13811.8 14810.2 15951.1
3D 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
202.7 833.2 1902.9 2972.5 4042.2 5111.9 6181.5 7251.2 8320.9 9390.5 10460.2 11529.9 12599.5 13669.2 14738.8 15808.5
4D 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
270.2 825.7 1966.7 3107.6 3963.4 5104.4 6245.3 7386.3 8242.0 9383.0 10524.0 11665.0 12520.7 13661.7 14802.6 15943.6
5D 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
337.8 694.3 1764.0 2833.7 3903.3 4973.0 6042.7 7112.3 8182.0 9251.7 10321.3 11391.0 12460.7 13530.3 14600.0 15669.6
6D 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
405.3 833.2 1688.9 2972.5 3828.3 5111.9 5967.6 7251.2 8106.9 9390.5 10246.3 11529.9 12385.6 13669.2 14524.9 15808.5
7D 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
472.9 972.1 1970.4 2968.8 3967.1 4965.5 5963.8 6962.2 8459.7 9458.1 10456.4 11454.8 12453.1 13451.5 14449.8 15947.4
8D 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
540.4 540.4 1681.4 2822.4 3963.4 5104.4 6245.3 7386.3 7956.8 9097.8 10238.7 11379.7 12520.7 13661.7 14802.6 15943.6
9D 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
608.0 608.0 1891.6 2533.4 3817.0 5100.6 5742.4 7026.0 8309.6 8951.4 10235.0 11518.6 12160.4 13444.0 14727.6 15369.4
10D 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
675.6 675.6 1388.7 2814.9 3528.0 4954.2 5667.3 7093.6 7806.7 9232.9 9946.0 11372.2 12085.3 13511.5 14224.7 15650.9
11D 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
743.1 743.1 1527.5 3096.4 3880.8 4665.2 6234.1 7018.5 7802.9 9371.7 10156.2 10940.6 12509.4 13293.9 14862.7 15647.1
12D 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
810.7 810.7 1666.4 2522.1 3377.9 5089.3 5945.1 6800.8 7656.5 9368.0 10223.7 11079.5 11935.2 13646.7 14502.4 15358.1
13D 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
878.2 878.2 1805.3 2732.3 3659.4 4586.4 5513.4 7367.5 8294.6 9221.6 10148.7 11075.7 12002.7 12929.8 14783.9 15710.9
14D 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
945.8 945.8 1944.1 2942.5 3940.8 4939.2 5937.6 6935.9 7934.3 8932.6 9931.0 10929.3 11927.7 12926.0 13924.4 15921.1
15D - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 1013.3 2083.0 3152.7 4222.3 5292.0 6361.7 7431.3 8501.0 9570.7 10640.3 11710.0 12779.7 13849.3 14919.0
16D - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 1080.9 2221.9 3362.8 4503.8 5644.8 6785.8 7926.8 9067.7 10208.7 11349.7 12490.7 13631.6 14772.6 15913.6
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
16949.5 18090.5 19088.8 20229.8 21228.1 22369.1 23367.5 24508.5 25506.8 26647.8 27646.1 28787.1 29785.5 30926.4 31924.8
3D 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
16878.2 17947.8 19017.5 20087.2 21156.8 22226.5 23296.2 24365.8 25435.5 26505.2 27574.8 28644.5 29714.2 30783.8 31853.5
4D 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
16799.4 17940.3 19081.3 20222.3 21078.0 22219.0 23360.0 24500.9 25356.7 26497.7 27638.6 28779.6 29635.3 30776.3 31917.3
5D 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
16739.3 17809.0 18878.6 19948.3 21018.0 22087.6 23157.3 24227.0 25296.6 26366.3 27436.0 28505.6 29575.3 30645.0 31714.6
6D 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
16664.2 17947.8 18803.6 20087.2 20942.9 22226.5 23082.2 24365.8 25221.6 26505.2 27360.9 28644.5 29500.2 30783.8 31639.6
7D 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
16945.7 17944.1 18942.4 19940.8 20939.1 21937.5 23435.0 24433.4 25431.7 26430.1 27428.5 28426.8 29425.2 30922.7 31921.0
8D 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
16514.1 17655.1 18796.1 19937.0 21078.0 22219.0 23360.0 24500.9 25071.4 26212.4 27353.4 28494.4 29635.3 30776.3 31917.3
9D 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
16653.0 17936.6 18578.4 19862.0 21145.6 21787.4 23071.0 24354.6 24996.4 26280.0 27563.6 28205.4 29489.0 30772.6 31414.4
10D 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
16364.0 17790.2 18503.3 19929.5 20642.6 22068.9 22782.0 24208.2 24921.3 26347.5 27060.6 28486.9 29200.0 30626.2 31339.3
11D 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
16431.5 18000.4 18784.8 19569.2 21138.1 21922.5 22706.9 24275.7 25060.2 26629.0 27413.4 28197.9 29766.7 30551.1 31335.5
12D 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
16213.8 17925.3 18781.0 19636.8 20492.5 22204.0 23059.7 23915.4 24771.2 26482.6 27338.4 28194.1 29049.8 30761.3 31617.0
13D 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
16638.0 17565.0 18492.0 19419.1 21273.2 22200.2 23127.3 24054.3 24981.3 25908.4 26835.4 28689.5 29616.6 30543.6 31470.6
14D 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
16919.4 17917.8 18916.2 19914.5 20912.9 21911.2 22909.6 23907.9 24906.3 25904.6 26903.0 27901.3 28899.7 30896.4 31894.8
15D 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
15988.7 17058.3 18128.0 19197.6 20267.3 21337.0 22406.6 23476.3 24546.0 25615.6 26685.3 27755.0 28824.6 29894.3 30964.0
16D 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
15913.6 17054.6 18195.5 19336.5 20477.5 21618.5 22759.4 23900.4 25041.4 26182.4 27323.3 28464.3 29605.3 30746.3 31887.2
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 187
Table D.6 List of Capacities Corresponding to RAID 1 (72 Gbytes)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
1D+1P 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
67.6 487.9 987.1 1557.6 2056.8 2627.2 3126.4 3696.9 4196.1 4766.6 5265.7 5836.2 6335.4 6905.9 7405.1 7975.6
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
1D+1P 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
(注
) 8474.7 9045.2 9544.4 10114.9 10614.1 11184.6 11683.7 12254.2 12753.4 13323.9 13823.1 14393.6 14892.7 15463.2 15962.4
Table D.7 List of Capacities Corresponding to RAID 5 (72 Gbytes) (continues on the following page)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+1P 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
135.1 555.5 1268.6 1981.7 2694.8 3407.9 4121.0 4834.1 5547.2 6260.3 6973.5 7686.6 8399.7 9112.8 9825.9 10539.0
3D+1P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
202.7 619.3 1475.0 2330.7 2972.5 3828.3 4684.0 5539.7 6181.5 7037.3 7893.0 8748.7 9390.5 10246.3 11102.0 11957.7
4D+1P 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
270.2 555.5 1411.2 2266.9 3122.7 3978.4 4834.1 5689.9 6545.6 7401.3 8257.1 9112.8 9968.5 10824.3 11680.0 12535.7
5D+1P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
337.8 694.3 1407.4 2477.1 3190.2 4259.9 4973.0 6042.7 6755.8 7825.4 8538.5 9608.2 10321.3 11391.0 12104.1 13173.8
6D+1P 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
405.3 833.2 1688.9 2544.7 3400.4 4256.1 5111.9 5967.6 7251.2 8106.9 8962.7 9818.4 10674.1 11529.9 12385.6 13669.2
7D+1P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
472.9 472.9 1471.2 2469.6 3468.0 4466.3 5464.7 6463.0 6962.2 7960.5 8958.9 9957.3 10955.6 11954.0 12952.3 13950.7
8D+1P 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
540.4 540.4 1681.4 2251.9 3392.9 4533.9 5104.4 6245.3 7386.3 7956.8 9097.8 10238.7 10809.2 11950.2 13091.2 13661.7
9D+1P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
608.0 608.0 1249.8 2533.4 3175.2 4458.8 5100.6 6384.2 7026.0 8309.6 8951.4 10235.0 10876.8 12160.4 12802.2 14085.8
10D+1P 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
675.6 675.6 1388.7 2814.9 3528.0 4241.1 5667.3 6380.4 7093.6 8519.8 9232.9 9946.0 11372.2 12085.3 13511.5 14224.7
11D+1P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
743.1 743.1 1527.5 2312.0 3096.4 4665.2 5449.6 6234.1 7018.5 8587.3 9371.7 10156.2 10940.6 12509.4 13293.9 14078.3
12D+1P 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
810.7 810.7 1666.4 2522.1 3377.9 4233.6 5089.3 6800.8 7656.5 8512.3 9368.0 10223.7 11079.5 11935.2 13646.7 14502.4
13D+1P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
878.2 878.2 1805.3 2732.3 3659.4 4586.4 5513.4 6440.5 7367.5 8294.6 9221.6 10148.7 11075.7 12002.7 12929.8 14783.9
14D+1P - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 945.8 1944.1 2942.5 3940.8 4939.2 5937.6 6935.9 7934.3 8932.6 9931.0 10929.3 11927.7 12926.0 13924.4
15D+1P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 1013.3 2083.0 3152.7 4222.3 5292.0 6361.7 7431.3 8501.0 9570.7 10640.3 11710.0 12779.7 13849.3 14919.0
188 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Table D.7 List of Capacities Corresponding to RAID 5 (72 Gbytes) (continued)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+1P 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
11252.1 11965.2 12678.3 13391.4 14104.6 14817.7 15530.8 16243.9 16957.0 17670.1 18383.2 19096.3 19809.4 20522.5 21235.7
3D+1P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
12599.5 13455.2 14311.0 15166.7 15808.5 16664.2 17520.0 18375.7 19017.5 19873.2 20729.0 21584.7 22226.5 23082.2 23938.0
4D+1P 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
13391.4 14247.2 15102.9 15958.6 16814.4 17670.1 18525.8 19381.6 20237.3 21093.0 21948.8 22804.5 23660.2 24516.0 25371.7
5D+1P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
13886.9 14956.5 15669.6 16739.3 17452.4 18522.1 19235.2 20304.9 21018.0 22087.6 22800.7 23870.4 24583.5 25653.2 26366.3
6D+1P 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
14524.9 15380.6 16236.4 17092.1 17947.8 18803.6 20087.2 20942.9 21798.6 22654.4 23510.1 24365.8 25221.6 26505.2 27360.9
7D+1P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
14449.8 15448.2 16446.6 17444.9 18443.3 19441.6 20440.0 21438.3 21937.5 22935.9 23934.2 24932.6 25930.9 26929.3 27927.6
8D+1P 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
14802.6 15943.6 16514.1 17655.1 18796.1 19366.6 20507.5 21648.5 22219.0 23360.0 24500.9 25071.4 26212.4 27353.4 27923.9
9D+1P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
14727.6 16011.2 16653.0 17936.6 18578.4 19862.0 20503.8 21787.4 22429.2 23712.8 24354.6 25638.2 26280.0 27563.6 28205.4
10D+1P 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
14937.8 16364.0 17077.1 17790.2 19216.4 19929.5 20642.6 22068.9 22782.0 24208.2 24921.3 25634.4 27060.6 27773.7 28486.9
11D+1P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
14862.7 16431.5 17216.0 18000.4 18784.8 20353.6 21138.1 21922.5 22706.9 24275.7 25060.2 25844.6 26629.0 28197.9 28982.3
12D+1P 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
15358.1 16213.8 17069.6 17925.3 19636.8 20492.5 21348.2 22204.0 23059.7 23915.4 24771.2 26482.6 27338.4 28194.1 29049.8
13D+1P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
15710.9 16638.0 17565.0 18492.0 19419.1 20346.1 21273.2 22200.2 23127.3 24054.3 24981.3 25908.4 26835.4 28689.5 29616.6
14D+1P 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
14922.7 15921.1 16919.4 17917.8 18916.2 19914.5 20912.9 21911.2 22909.6 23907.9 24906.3 25904.6 26903.0 27901.3 28899.7
15D+1P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
14919.0 15988.7 17058.3 18128.0 19197.6 20267.3 21337.0 22406.6 23476.3 24546.0 25615.6 26685.3 27755.0 28824.6 29894.3
Table D.8 List of Capacities Corresponding to RAID 1+0 (72 Gbytes) (continues on the following page)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+2P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
135.1 412.8 983.3 1553.8 1981.7 2552.2 3122.7 3693.2 4121.0 4691.5 5262.0 5832.5 6260.3 6830.8 7401.3 7971.8
3D+3P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
202.7 416.6 844.5 1486.3 1914.1 2555.9 2983.8 3625.6 4053.5 4695.3 5123.1 5764.9 6192.8 6834.6 7262.5 7904.3
4D+4P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
270.2 270.2 840.7 1411.2 1981.7 2552.2 3122.7 3693.2 3978.4 4548.9 5119.4 5689.9 6260.3 6830.8 7401.3 7971.8
5D+5P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
341.5 337.8 694.3 1407.4 1764.0 2477.1 2833.7 3546.8 3903.3 4616.4 4973.0 5686.1 6042.7 6755.8 7112.3 7825.4
6D+6P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
412.8 405.3 833.2 1261.1 1688.9 2544.7 2972.5 3400.4 3828.3 4684.0 5111.9 5539.7 5967.6 6823.3 7251.2 7679.1
7D+7P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
484.2 472.9 972.1 1471.2 1970.4 2469.6 2968.8 3468.0 3967.1 4466.3 4965.5 5464.7 5963.8 6463.0 6962.2 7960.5
8D+8P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 540.4 1110.9 1681.4 2251.9 2822.4 3392.9 3963.4 4533.9 5104.4 5674.8 6245.3 6815.8 7386.3 7956.8
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 189
Table D.8 List of Capacities Corresponding to RAID 1+0 (72 Gbytes) (continued)
Disk capacity 71.3 G bytes
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+2P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
8399.7 8970.2 9540.7 10111.1 10539.0 11109.5 11680.0 12250.5 12678.3 13248.8 13819.3 14389.8 14817.7 15388.2 15958.6
3D+3P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
8332.1 8973.9 9401.8 10043.6 10471.5 11113.3 11541.1 12182.9 12610.8 13252.6 13680.4 14322.2 14750.1 15391.9 15819.8
4D+4P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
8257.1 8827.5 9398.0 9968.5 10539.0 11109.5 11680.0 12250.5 12535.7 13106.2 13676.7 14247.2 14817.7 15388.2 15958.6
5D+5P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
8182.0 8895.1 9251.7 9964.8 10321.3 11034.4 11391.0 12104.1 12460.7 13173.8 13530.3 14243.4 14600.0 15313.1 15669.6
6D+6P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
8106.9 8962.7 9390.5 9818.4 10246.3 11102.0 11529.9 11957.7 12385.6 13241.3 13669.2 14097.0 14524.9 15380.6 15808.5
7D+7P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
8459.7 8958.9 9458.1 9957.3 10456.4 10955.6 11454.8 11954.0 12453.1 12952.3 13451.5 13950.7 14449.8 15448.2 15947.4
8D+8P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
7956.8 8527.3 9097.8 9668.3 10238.7 10809.2 11379.7 11950.2 12520.7 13091.2 13661.7 14232.2 14802.6 15373.1 15943.6
Table D.9 List of Capacities Corresponding to RAID 0 (146 Gbytes) (continues on the following page)
Disk capacity 143.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
279.1 1983.8 3990.1 6283.0 8289.3 10582.2 12588.5 14881.4 16887.7 19180.6 21186.9 23479.8 25486.1 27779.0 29785.3 32078.2
3D 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
418.7 1697.1 3846.8 5996.4 8146.0 10295.6 12445.2 14594.8 16744.4 18894.0 21043.6 23193.2 25342.8 27492.4 29642.0 31791.6
4D 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
558.2 1689.6 3982.5 6275.5 7995.1 10288.1 12581.0 14873.9 16593.6 18886.5 21179.4 23472.3 25192.0 27484.9 29777.8 32070.7
5D 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
697.8 1414.3 3563.9 5713.5 7863.1 10012.7 12162.3 14311.9 16461.5 18611.1 20760.7 22910.3 25059.9 27209.6 29359.2 31508.8
6D 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
837.3 1697.1 3416.8 5996.4 7716.0 10295.6 12015.3 14594.8 16314.5 18894.0 20613.7 23193.2 24912.9 27492.4 29212.1 31791.6
7D 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
976.9 1980.0 3986.3 5992.6 7998.9 10005.2 12011.5 14017.8 17027.2 19033.5 21039.8 23046.1 25052.4 27058.7 29065.0 32074.5
8D 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
1116.4 1116.4 3409.3 5702.2 7995.1 10288.1 12581.0 14873.9 16020.3 18313.2 20606.2 22899.1 25192.0 27484.9 29777.8 32070.7
9D 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
1256.0 1256.0 3835.5 5125.2 7704.8 10284.3 11574.1 14153.6 16733.1 18022.9 20602.4 23181.9 24471.7 27051.2 29630.7 30920.5
10D 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
1395.5 1395.5 2828.6 5694.7 7127.8 9993.9 11427.0 14293.1 15726.2 18592.4 20025.4 22891.6 24324.6 27190.8 28623.8 31490.0
11D 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
1535.1 1535.1 3111.4 6264.2 7840.6 9416.9 12569.7 14146.1 15722.5 18875.2 20451.6 22028.0 25180.7 26757.1 29909.8 31486.2
12D 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
1674.6 1674.6 3394.3 5114.0 6833.7 10273.0 11992.7 13712.4 15432.1 18871.5 20591.1 22310.8 24030.5 27469.9 29189.6 30909.2
13D 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
1814.2 1814.2 3677.2 5540.1 7403.1 9266.1 11129.1 14855.1 16718.1 18581.1 20444.1 22307.1 24170.1 26033.0 29759.0 31622.0
14D 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
1953.7 1953.7 3960.0 5966.3 7972.6 9978.9 11985.2 13991.5 15997.8 18004.1 20010.4 22016.7 24023.0 26029.3 28035.6 32048.2
15D - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 2093.3 4242.9 6392.5 8542.1 10691.7 12841.3 14990.9 17140.5 19290.1 21439.7 23589.3 25738.9 27888.5 30038.1
16D - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 2232.8 4525.7 6818.6 9111.6 11404.5 13697.4 15990.3 18283.2 20576.1 22869.0 25161.9 27454.8 29747.8 32040.7
190 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Table D.9 List of Capacities Corresponding to RAID 0 (146 Gbytes) (continued)
Disk capacity 143.3 G bytes
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
34084.5 36377.4 38383.7 40676.7 42683.0 44975.9 46982.2 49275.1 51281.4 53574.3 55580.6 57873.5 59879.8 62172.7 64179.0
3D 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
33941.2 36090.8 38240.4 40390.0 42539.6 44689.2 46838.9 48988.5 51138.1 53287.7 55437.3 57586.9 59736.5 61886.1 64035.7
4D 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
33790.4 36083.3 38376.2 40669.1 42388.8 44681.7 46974.6 49267.6 50987.2 53280.2 55573.1 57866.0 59585.7 61878.6 64171.5
5D 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
33658.4 35808.0 37957.6 40107.2 42256.8 44406.4 46556.0 48705.6 50855.2 53004.8 55154.4 57304.0 59453.6 61603.2 63752.8
6D 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
33511.3 36090.8 37810.5 40390.0 42109.7 44689.2 46408.9 48988.5 50708.1 53287.7 55007.4 57586.9 59306.6 61886.1 63605.8
7D 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
34080.8 36087.1 38093.4 40099.7 42106.0 44112.3 47121.7 49128.0 51134.3 53140.6 55146.9 57153.2 59159.5 62168.9 64175.2
8D 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
33217.2 35510.1 37803.0 40095.9 42388.8 44681.7 46974.6 49267.6 50414.0 52706.9 54999.8 57292.8 59585.7 61878.6 64171.5
9D 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
33500.0 36079.6 37369.3 39948.8 42528.4 43818.1 46397.7 48977.2 50267.0 52846.5 55426.0 56715.8 59295.3 61874.8 63164.6
10D 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
32923.1 35789.2 37222.3 40088.4 41521.5 44387.6 45820.7 48686.8 50119.9 52986.0 54419.1 57285.2 58718.3 61584.5 63017.5
11D 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
33062.6 36215.4 37791.7 39368.1 42520.9 44097.2 45673.6 48826.4 50402.7 53555.5 55131.9 56708.3 59861.0 61437.4 63013.8
12D 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
32628.9 36068.3 37788.0 39507.7 41227.3 44666.7 46386.4 48106.1 49825.8 53265.1 54984.8 56704.5 58424.2 61863.6 63583.2
13D 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
33485.0 35348.0 37211.0 39074.0 42800.0 44663.0 46525.9 48388.9 50251.9 52114.9 53977.9 57703.9 59566.9 61429.9 63292.9
14D 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
34054.5 36060.8 38067.1 40073.4 42079.7 44086.0 46092.3 48098.6 50104.9 52111.2 54117.5 56123.8 58130.1 62142.7 64149.0
15D 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
32187.7 34337.3 36486.9 38636.6 40786.2 42935.8 45085.4 47235.0 49384.6 51534.2 53683.8 55833.4 57983.0 60132.6 62282.2
16D 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
32040.7 34333.6 36626.5 38919.4 41212.3 43505.2 45798.1 48091.1 50384.0 52676.9 54969.8 57262.7 59555.6 61848.5 64141.4
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
1D+1P 2 14 28 44 58 74 88 104 118 134 148 164 178 194 208 224
139.6 991.9 1995.0 3141.5 4144.6 5291.1 6294.2 7440.7 8443.8 9590.3 10593.5 11739.9 12743.1 13889.5 14892.7 16039.1
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
1D+1P 238 254 268 284 298 314 328 344 358 374 388 404 418 434 448
17042.3 18188.7 19191.9 20338.3 21341.5 22487.9 23491.1 24637.5 25640.7 26787.1 27790.3 28936.7 29939.9 31086.4 32089.5
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 191
Table D.11 List of Capacities Corresponding to RAID 5 (146 Gbytes)
Disk capacity 143.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+1P 3 12 27 42 57 72 87 102 117 132 147 162 177 192 207 222
279.1 1131.4 2564.5 3997.6 5430.6 6863.7 8296.8 9729.9 11162.9 12596.0 14029.1 15462.1 16895.2 18328.3 19761.3 21194.4
3D+1P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
418.7 1267.2 2986.9 4706.6 5996.4 7716.0 9435.7 11155.4 12445.2 14164.9 15884.5 17604.2 18894.0 20613.7 22333.4 24053.0
4D+1P 5 10 25 40 55 70 85 100 115 130 145 160 175 190 205 220
558.2 1131.4 2851.1 4570.8 6290.5 8010.2 9729.9 11449.5 13169.2 14888.9 16608.6 18328.3 20048.0 21767.6 23487.3 25207.0
5D+1P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
697.8 1414.3 2847.4 4997.0 6430.0 8579.6 10012.7 12162.3 13595.4 15745.0 17178.1 19327.7 20760.7 22910.3 24343.4 26493.0
6D+1P 7 14 28 42 56 70 84 98 119 133 147 161 175 189 203 224
837.3 1697.1 3416.8 5136.5 6856.2 8575.9 10295.6 12015.3 14594.8 16314.5 18034.1 19753.8 21473.5 23193.2 24912.9 27492.4
7D+1P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
976.9 976.9 2983.2 4989.5 6995.8 9002.0 11008.3 13014.6 14017.8 16024.1 18030.4 20036.7 22043.0 24049.3 26055.6 28061.9
8D+1P 9 9 27 36 54 72 81 99 117 126 144 162 171 189 207 216
1116.4 1116.4 3409.3 4555.8 6848.7 9141.6 10288.1 12581.0 14873.9 16020.3 18313.2 20606.2 21752.6 24045.5 26338.4 27484.9
9D+1P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
1256.0 1256.0 2545.7 5125.2 6415.0 8994.5 10284.3 12863.8 14153.6 16733.1 18022.9 20602.4 21892.2 24471.7 25761.5 28341.0
10D+1P 11 11 22 44 55 66 88 99 110 132 143 154 176 187 209 220
1395.5 1395.5 2828.6 5694.7 7127.8 8560.9 11427.0 12860.1 14293.1 17159.3 18592.4 20025.4 22891.6 24324.6 27190.8 28623.8
11D+1P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
1535.1 1535.1 3111.4 4687.8 6264.2 9416.9 10993.3 12569.7 14146.1 17298.8 18875.2 20451.6 22028.0 25180.7 26757.1 28333.5
12D+1P 13 13 26 39 52 65 78 104 117 130 143 156 169 182 208 221
1674.6 1674.6 3394.3 5114.0 6833.7 8553.3 10273.0 13712.4 15432.1 17151.8 18871.5 20591.1 22310.8 24030.5 27469.9 29189.6
13D+1P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
1814.2 1814.2 3677.2 5540.1 7403.1 9266.1 11129.1 12992.1 14855.1 16718.1 18581.1 20444.1 22307.1 24170.1 26033.0 29759.0
14D+1P - - 15 30 45 60 75 90 105 120 135 150 165 180 195 210
- - 1953.7 3960.0 5966.3 7972.6 9978.9 11985.2 13991.5 15997.8 18004.1 20010.4 22016.7 24023.0 26029.3 28035.6
15D+1P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 2093.3 4242.9 6392.5 8542.1 10691.7 12841.3 14990.9 17140.5 19290.1 21439.7 23589.3 25738.9 27888.5 30038.1
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+1P 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447
22627.5 24060.6 25493.6 26926.7 28359.8 29792.8 31225.9 32659.0 34092.0 35525.1 36958.2 38391.3 39824.3 41257.4 42690.5
3D+1P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
25342.8 27062.5 28782.2 30501.9 31791.6 33511.3 35231.0 36950.7 38240.4 39960.1 41679.8 43399.5 44689.2 46408.9 48128.6
4D+1P 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445
26926.7 28646.4 30366.1 32085.7 33805.4 35525.1 37244.8 38964.5 40684.2 42403.8 44123.5 45843.2 47562.9 49282.6 51002.3
5D+1P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
27926.1 30075.7 31508.8 33658.4 35091.4 37241.0 38674.1 40823.7 42256.8 44406.4 45839.5 47989.1 49422.1 51571.7 53004.8
6D+1P 238 252 266 280 294 308 329 343 357 371 385 399 413 434 448
29212.1 30931.8 32651.5 34371.1 36090.8 37810.5 40390.0 42109.7 43829.4 45549.1 47268.8 48988.5 50708.1 53287.7 55007.4
7D+1P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
29065.0 31071.3 33077.6 35083.9 37090.2 39096.5 41102.8 43109.1 44112.3 46118.6 48124.9 50131.2 52137.5 54143.8 56150.1
8D+1P 234 252 261 279 297 306 324 342 351 369 387 396 414 432 441
29777.8 32070.7 33217.2 35510.1 37803.0 38949.5 41242.4 43535.3 44681.7 46974.6 49267.6 50414.0 52706.9 54999.8 56146.3
9D+1P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
29630.7 32210.3 33500.0 36079.6 37369.3 39948.8 41238.6 43818.1 45107.9 47687.4 48977.2 51556.7 52846.5 55426.0 56715.8
10D+1P 231 253 264 275 297 308 319 341 352 374 385 396 418 429 440
30056.9 32923.1 34356.1 35789.2 38655.3 40088.4 41521.5 44387.6 45820.7 48686.8 50119.9 51553.0 54419.1 55852.2 57285.2
11D+1P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
29909.8 33062.6 34639.0 36215.4 37791.7 40944.5 42520.9 44097.2 45673.6 48826.4 50402.7 51979.1 53555.5 56708.3 58284.6
12D+1P 234 247 260 273 299 312 325 338 351 364 377 403 416 429 442
30909.2 32628.9 34348.6 36068.3 39507.7 41227.3 42947.0 44666.7 46386.4 48106.1 49825.8 53265.1 54984.8 56704.5 58424.2
13D+1P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
31622.0 33485.0 35348.0 37211.0 39074.0 40937.0 42800.0 44663.0 46525.9 48388.9 50251.9 52114.9 53977.9 57703.9 59566.9
14D+1P 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435
30041.9 32048.2 34054.5 36060.8 38067.1 40073.4 42079.7 44086.0 46092.3 48098.6 50104.9 52111.2 54117.5 56123.8 58130.1
15D+1P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
30038.1 32187.7 34337.3 36486.9 38636.6 40786.2 42935.8 45085.4 47235.0 49384.6 51534.2 53683.8 55833.4 57983.0 60132.6
192 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Table D.12 List of Capacities Corresponding to RAID 1+0 (146 Gbytes)
Disk capacity 143.3 G bytes
Component RKA
unit
Range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Total range of Min. 14 29 44 59 74 89 104 119 134 149 164 179 194 209 224
Disk drives
2D+2P 4 12 28 44 56 72 88 104 116 132 148 164 176 192 208 224
279.1 844.8 1991.3 3137.7 3997.6 5144.0 6290.5 7436.9 8296.8 9443.2 10589.7 11736.2 12596.0 13742.4 14888.9 16035.4
3D+3P 6 12 24 42 54 72 84 102 114 132 144 162 174 192 204 222
418.7 848.6 1708.4 2998.2 3858.0 5147.8 6007.6 7297.4 8157.2 9447.0 10306.8 11596.6 12456.4 13746.2 14606.0 15895.8
4D+4P 8 8 24 40 56 72 88 104 112 128 144 160 176 192 208 224
558.2 558.2 1704.7 2851.1 3997.6 5144.0 6290.5 7436.9 8010.2 9156.6 10303.1 11449.5 12596.0 13742.4 14888.9 16035.4
5D+5P 10 10 20 40 50 70 80 100 110 130 140 160 170 190 200 220
701.5 697.8 1414.3 2847.4 3563.9 4997.0 5713.5 7146.6 7863.1 9296.2 10012.7 11445.8 12162.3 13595.4 14311.9 15745.0
6D+6P 12 12 24 36 48 72 84 96 108 132 144 156 168 192 204 216
844.8 837.3 1697.1 2557.0 3416.8 5136.5 5996.4 6856.2 7716.0 9435.7 10295.6 11155.4 12015.3 13734.9 14594.8 15454.6
7D+7P 14 14 28 42 56 70 84 98 112 126 140 154 168 182 196 224
988.1 976.9 1980.0 2983.2 3986.3 4989.5 5992.6 6995.8 7998.9 9002.0 10005.2 11008.3 12011.5 13014.6 14017.8 16024.1
8D+8P - - 16 32 48 64 80 96 112 128 144 160 176 192 208 224
- - 1116.4 2262.9 3409.3 4555.8 5702.2 6848.7 7995.1 9141.6 10288.1 11434.5 12581.0 13727.4 14873.9 16020.3
Table D.12 List of Capacities Corresponding to RAID 1+0 (146 Gbytes) (continued)
Disk capacity 143.3 G bytes
Component RKA
unit
Range 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Total range of 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449
Disk drives (Max)
2D+2P 236 252 268 284 296 312 328 344 356 372 388 404 416 432 448
16895.2 18041.7 19188.1 20334.6 21194.4 22340.9 23487.3 24633.8 25493.6 26640.1 27786.5 28933.0 29792.8 30939.3 32085.7
3D+3P 234 252 264 282 294 312 324 342 354 372 384 402 414 432 444
16755.7 18045.4 18905.3 20195.0 21054.9 22344.6 23204.5 24494.2 25354.1 26643.8 27503.7 28793.4 29653.3 30943.0 31802.9
4D+4P 232 248 264 280 296 312 328 344 352 368 384 400 416 432 448
16608.6 17755.0 18901.5 20048.0 21194.4 22340.9 23487.3 24633.8 25207.0 26353.5 27499.9 28646.4 29792.8 30939.3 32085.7
5D+5P 230 250 260 280 290 310 320 340 350 370 380 400 410 430 440
16461.5 17894.6 18611.1 20044.2 20760.7 22193.8 22910.3 24343.4 25059.9 26493.0 27209.6 28642.6 29359.2 30792.2 31508.8
6D+6P 228 252 264 276 288 312 324 336 348 372 384 396 408 432 444
16314.5 18034.1 18894.0 19753.8 20613.7 22333.4 23193.2 24053.0 24912.9 26632.6 27492.4 28352.3 29212.1 30931.8 31791.6
7D+7P 238 252 266 280 294 308 322 336 350 364 378 392 406 434 448
17027.2 18030.4 19033.5 20036.7 21039.8 22043.0 23046.1 24049.3 25052.4 26055.6 27058.7 28061.9 29065.0 31071.3 32074.5
8D+8P 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448
16020.3 17166.8 18313.2 19459.7 20606.2 21752.6 22899.1 24045.5 25192.0 26338.4 27484.9 28631.4 29777.8 30924.3 32070.7
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 193
194 Appendix D List of Storage Capacities Corresponding to RAID Levels and Configurations
Appendix E Port Address Mapping Table
Fibre channel physical addresses are converted to target IDs (TIDs) using a conversion table.
The following table shows the current limits for TIDs on various operating systems.
AL-PA is an abbreviation for Arbitrated Loop Physical Address and indicates the physical
address for Fibre Channel. TID indicates the target ID.
C0 C1 C2 C3 C4 C5 C6 C7
ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID
EF 0 CD 0 B2 0 98 0 72 0 55 0 3A 0 25 0
E8 1 CC 1 B1 1 97 1 71 1 54 1 39 1 23 1
E4 2 CB 2 AE 2 90 2 6E 2 53 2 36 2 1F 2
E2 3 CA 3 AD 3 8F 3 6D 3 52 3 35 3 1E 3
E1 4 C9 4 AC 4 88 4 6C 4 51 4 34 4 1D 4
E0 5 C7 5 AB 5 84 5 6B 5 4E 5 33 5 1B 5
DC 6 C6 6 AA 6 82 6 6A 6 4D 6 32 6 18 6
DA 7 C5 7 A9 7 81 7 69 7 4C 7 31 7 17 7
D9 8 C3 8 A7 8 80 8 67 8 4B 8 2E 8 10 8
D6 9 BC 9 A6 9 7C 9 66 9 4A 9 2D 9 0F 9
D5 10 BA 10 A5 10 7A 10 65 10 49 10 2C 10 08 10
D4 11 B9 11 A3 11 79 11 63 11 47 11 2B 11 04 11
D3 12 B6 12 9F 12 76 12 5C 12 46 12 2A 12 02 12
D2 13 B5 13 9E 13 75 13 5A 13 45 13 29 13 01 13
D1 14 B4 14 9D 14 74 14 59 14 43 14 27 14
CE 15 B3 15 9B 15 73 15 56 15 3C 15 26 15
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 195
Table E.3 Port Addresses for Solaris
C0 C1 C2 C3 C4 C5 C6 C7
ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID ALPA TID
EF 0 CD 16 B2 32 98 48 72 64 55 80 3A 96 25 112
E8 1 CC 17 B1 33 97 49 71 65 54 81 39 97 23 113
E4 2 CB 18 AE 34 90 50 6E 66 53 82 36 98 1F 114
E2 3 CA 19 AD 35 8F 51 6D 67 52 83 35 99 1E 115
E1 4 C9 20 AC 36 88 52 6C 68 51 84 34 100 1D 116
E0 5 C7 21 AB 37 84 53 6B 69 4E 85 33 101 1B 117
DC 6 C6 22 AA 38 82 54 6A 70 4D 86 32 102 18 118
DA 7 C5 23 A9 39 81 55 69 71 4C 87 31 103 17 119
D9 8 C3 24 A7 40 80 56 67 72 4B 88 2E 104 10 120
D6 9 BC 25 A6 41 7C 57 66 73 4A 89 2D 105 0F 121
D5 10 BA 26 A5 42 7A 58 65 74 49 90 2C 106 08 122
D4 11 B9 27 A3 43 79 59 63 75 47 91 2B 107 04 123
D3 12 B6 28 9F 44 76 60 5C 76 46 92 2A 108 02 124
D2 13 B5 29 9E 45 75 61 5A 77 45 93 29 109 01 125
D1 14 B4 30 9D 46 74 62 59 78 43 94 27 110
CE 15 B3 31 9B 47 73 63 56 79 3C 95 26 111
TID AL TID AL TID AL TID AL TID AL TID AL TID AL TID AL TID AL TID
PA PA PA PA PA PA PA PA PA
CC 15 98 15 56 15 27 15
E4 30 CB 14 B1 30 67 14 72 30 55 14 3C 30 26 14
E2 29 CA 13 AE 29 90 13 71 29 64 13 3A 29 25 13
E1 28 C9 12 AD 28 8F 12 6E 28 53 12 39 28 23 12
E0 27 C7 11 AC 27 88 11 6D 27 52 11 36 27 1F 11
DC 26 C6 10 AB 26 84 10 6C 26 51 10 35 26 1E 10
DA 25 C5 9 AA 25 82 9 6B 25 4E 9 34 25 1D 9
D9 24 C3 8 A9 24 81 8 6A 24 4D 8 33 24 1B 8
D6 23 BC 7 A7 23 80 7 69 23 4C 7 32 23 18 7
D5 22 BA 6 A6 22 7C 6 67 22 4B 6 31 22 17 6
D4 21 B9 5 A5 21 7A 5 66 21 4A 5 2E 21 10 5
D3 20 B6 4 A3 20 79 4 65 20 49 4 2D 20 0F 4
D2 19 B5 3 9F 19 76 3 63 19 47 3 2C 19 08 3
D1 18 B4 2 9E 18 75 2 5C 18 46 2 2B 18 04 2
EF 1 CE 17 B3 1 9D 17 74 1 5A 17 45 1 2A 17 02 1
E8 0 CD 16 B2 0 9B 16 73 0 59 16 43 0 29 16 01 0
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 197
198 Appendix E Port Address Mapping Table
Appendix F Power Cables
This section includes descriptions of the following power cables:
J1H
J2H
J2H
J2H10
DC Power Cable
Cable name Part No. Name Quantity Model Applicable safety standard/
rating
L=2.5 m
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 199
Table F.2 J2H Power Cable
Cable name Part No. Name Quantity Model Applicable safety standard/
rating
L=2.5 m
Cable name Part No. Name Quantity Model Applicable safety standard/
rating
J2H5: L=5 m
J2H10: L=10 m
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 201
The number of logical blocks for one parity group is shown below.
*1: Maximum number of blocks 1 is applied for the RAID Group excluding the Drives #0 to #4 of RKA Unit#0.
Maximum number of blocks 2 is applied for the RAID Group including at least one Drive of the Drives #0 to #4 of RKA Unit#0.
When connecting to the servers (HBA) or exchanging the HBA, connect to the servers
(HBA) that access the Disk Array after the LUN Security or LUN Management settings,
including WWN registration, are completed.
Zoning on Fabric Switch must be set as shown below to disturb the access from HBA that
cannot be accessed from the Disk Array by LUN Security or LUN Management.
Host-A Host-B
Port 0A Port 1A
CTL 0 CTL 1
LU0(HBA#1,
HBA#2)
LU1(HBA#3)
Hitachi Freedom Storage™ Thunder 9580™ V Series User and Reference Guide 203
204 Appendix H Using LUN Security or LUN Management on Fabric Switch Connection