BulHY14 2000 B8
BulHY14 2000 B8
BulHY14 2000 B8
Pressure Compensated
Flow Control for Model VA/VG20,35
Power-Beyond Outlets
Series VA/VG20
VA/VG20
Par
Partt #355-9001-204
Contr olled Flow is 18 GPM (68 LPM)
Controlled
Outlet Por
Portt Size is SAE10
Series VA/VG35
VA/VG35
Par
Partt #355-9001-182
Contr olled Flow is 18 GPM (68 LPM)
Controlled
Outlet Por
Portt Size is SAE16
The above control module is inserted into the is in excess of the flow setting moves through
convertible power-beyond outlet in the place of the holes in the body, into the tank return
the standard conversion plug. Open-center passage in the outlet and then to the tank.
output flow is diverted through the orifice in the This feature is used on machines that have
spool in the control module. The orifice is sized add-on optional equipment requiring a smaller
so that a fixed amount of flow is directed to a flow than the main hydraulics system. Using
downstream function and in this case the flow control module, a 50 GPM main sys-
18 GPM (68 LPM). When this flow rate is tem flow can be stepped down to 18 GPM for
reached, the pressure drop across the orifice the add-on function.
is sufficient to move the spool off of its seat,
opening holes in the module's body. Flow that