Omada Controller PDF
Omada Controller PDF
Overview.................................................................................................................................. 2
1 Quick Start........................................................................................................................ 4
1.1 Determine the Management Method................................................................................................... 5
2.1.1 Configure SSIDs............................................................................................................................... 16
Radio Setting..................................................................................................................................... 22
Load Balance..................................................................................................................................... 24
Airtime Fairness............................................................................................................................... 24
More Settings................................................................................................................................... 25
Configure Portal............................................................................................................................................ 27
Detect Rogue APs and Move the Rogue APs to the Trusted AP List........................................ 48
6 Application Example...................................................................................................84
6.1 Determine the Network Requirements.............................................................................................85
Configure SSIDs............................................................................................................................................ 87
Configure Scheduler.................................................................................................................................... 90
The information in this document is subject to change without notice. Every effort has been made
in the preparation of this document to ensure the accuracy of the contents, but all statements,
information, and recommendations in this document do not constitute the warranty of any kind,
express or implied. Users must take full responsibility for their application of any product.
Convention
Unless otherwise noted, the introduction in this guide takes EAP245 as an example.
More Info
Some models featured in this guide may be unavailable in your country or region. For local sales
information, visit https://www.tp-link.com.
For technical support, latest software, and management app, visit https://www.tp-link.com/support .
The Quick Installation Guide can be found where you find this guide or inside the package of the
EAP.
To ask questions, find answers, and communicate with TP-Link users or engineers, please visit
https://community.tp-link.com to join TP-Link Community.
1
Overview
Omada series products provide wireless coverage solutions for small-medium business and
households. They can either work independently as standalone APs or be centrally managed by
the EAP Controller software or an Omada Cloud Controller (OC200), providing a flexible, richly-
functional but easily configured wireless network for small and medium business and households.
2
The following figure shows the front view of EAP225-Wall:
3
1 Quick Start
This chapter introduces how to build a wireless network using the EAPs and how to
complete the basic settings. Follow the steps below:
4
1.1 Determine the Management Method
Before building the wireless network, choose a proper method to manage the EAP based
on your actual network situation. Omada EAP supports two configuration option: Controller
Mode or Standalone Mode.
■■Controller Mode
If you want to establish a large-scale wireless network and have mass EAPs to be
managed, Controller Mode is recommended. In Controller Mode, all EAPs can be centrally
configured and monitored via an Omada Software Controller or an Omada Cloud Controller
(OC200).
For detailed instructions about the network topology in such situation and how to use an
Omada Software Controller or an OC200, refer to the User Guide of Omada Controller or
OC200. To download Omada Software Controller and its User Guide, go to https://www.
tp-link.com/en/download/EAP-Controller.html . And the User Guide of OC200 can be
downloaded at https://www.tp-link.com/en/download/OC200.html .
■■Standalone Mode
If you have a relatively small-sized wireless network and only one or just a small number
of EAPs need to be managed, Standalone Mode is recommended. In Standalone Mode,
each EAP can be configured singly by the Omada app or the web browser on its own
management web page.
Omada app is a mobile application designed for conveniently managing Omada series EAP
products. For detailed instructions about how to use Omada app to manage your network,
please refer to the appendix of this User Guide: Appendix: Omada App .
This User Guide introduces how to configure the Standalone EAP on its web page.
Note
The web page of an EAP is inaccessible while it is managed by Omada Controller. To turn the EAP
back to Standalone Mode and access its web page, you can Forget the EAP on Omada Controller to
reset the EAP or simply close Omada Controller.
5
1.2 Build the Network Topology
To manage the EAPs in Standalone mode, refer to the following topology.
PC EAP EAP
IP: 192.168.0.100
Clients
• The router is the gateway of the network, and devices in the LAN surf the internet via
the router. At the same time, the router acts as a DHCP server to assign dynamic IP
addresses to the EAPs and clients.
• The PC and the EAPs are all connected to the Layer 2 switch. Since the PC and the EAPs
are in the same network segment, the PC can log in to the web pages of the EAPs and
manage them.
6
1.3 Log In to the EAP
The following sections introduce how to log in to the EAP via a wireless connection and a
wired connection.
2. Search the default SSID (Network name) using your wireless client device and connect
to the wireless network of the EAP. The default SSID of the EAP is printed on the
product label at the bottom of the device. The dual-band EAP has two default SSIDs
named TP-Link_2.4GHz_XXXXXX and TP-Link_5GHz_XXXXXX on the 2.4GHz band
and 5GHz band, and the single-band EAP has a default SSID named TP-Link_2.4GHz_
XXXXXX on the 2.4GHz band.
7
3. Make sure that the wireless client has been assigned the IP address and has got the IP
address of the DNS server and the gateway.
4. Launch a web browser on the client device and enter http://tplinkeap.net in the
address bar to load the login page of the EAP. Use admin for both of the username and
password to log in.
Tips
To facilitate access to the EAP via a wired device, you can set a static IP address for the EAP and
remember it well or write it down. But make sure that this IP address is not being used in the same
LAN. For detailed instructions about how to set a static IP address for the EAP, refer to Manage the
IP Address of the EAP .
8
1.3.2 Log In via a wired connection
For a wired connection, you can only log in to the EAP via its IP address. In this method,
you need to know the IP address of the EAP first. Follow the steps below to log in via the IP
address of the EAP with a wired client. The method of log in via the IP address wirelessly is
similar.
• Log in to the router which acts as the DHCP server. In the DHCP client list, find the IP
address of your EAP according to its MAC address. The MAC address can be found
at the bottom of the EAP.
• Go to http://www.tp-link.com/en/download/EAP-Controller.html#EAP_Discovery_
Tool to download EAP Discovery Utility. EAP Discovery Utility is a software that can
scan all EAPs in the same network segment. Install and launch EAP Discovery Utility
on the PC, and find the IP address of the EAP. In the following figure, the IP address of
the EAP is 192.168.0.5.
9
2. Launch a web browser and enter 192.168.0.5 in the address bar to load the login page
of the EAP. Use admin for both of the username and password to log in.
Tips
••To facilitate access to the EAP via a wired device, you can set a static IP address for the EAP and
remember it well or write it down. But make sure that this IP address is not being used in the same
LAN. For detailed instructions about how to set a static IP address for the EAP, refer to Manage
the IP Address of the EAP .
••The DHCP fallback IP address is 192.168.0.254 by default, which you can use to log in to its
web management page when the DHCP server is not available in your network. Follow the steps
below:
1. Connect the EAP to your computer with an Ethernet Cable.
2. Assign a static IP address 192.168.0.X (X ranges between 2 and 253) together with the subnet
mask 255.255.255.0 to your computer.
3. Open a web browser and enter 192.168.0.254 in the address bar to load the login page of the
EAP.
10
1.4 Do the Basic Configurations
After Logging in to EAP, follow the step-by-step instructions to complete the basic
configurations.
1. In the pop-up window, configure a new username and a new password for your user
account, then click Next.
2. For the dual-band EAP, select at least one radio band between 2.4GHz and 5GHz to
configure the SSID and password. For the single-band EAP, configure the SSID and
password on the 2.4GHz band. Click Save.
11
3. The following page will appear. Make sure that your device has connected to the new
wireless network and tick the checkbox. Then click Finish.
Tips
If needed, you can also create more new SSIDs. For detailed instructions about how to create new
SSIDs, refer to Configure SSIDs .
12
1.5 Configure and Manage the EAP
After all the steps above are completed, the legal wireless clients can enjoy the internet via
the EAP. Additionally, you can configure the advanced functions of the EAP according to
your need, and manage it conveniently on the web page.
On the top of the page, you can click to log out and click to open the technical
support website.
There are four tabs: Status, Wireless, Management and System. The following table
introduces what you can configure under each tab.
Status You can view the information of the EAP, wireless traffic and clients.
Wireless You can configure the wireless parameters and the advanced features, such
as Portal, VLAN, MAC Filtering, Scheduler, Band Steering, QoS and Rogue AP
Detection.
Management You can manage the EAP using the management features, such as System
Logs, Web Server, Management Access, LED Control, SSH and SNMP.
System You can configure the system parameters, including the login account and
the system time. In addition, you can reboot and reset the EAP, backup and
restore the configuration, and upgrade the EAP using the new firmware file.
13
2 Configure the Network
This chapter introduces how to configure the network parameters and the advanced
features of the EAP, including:
••Configure VLAN
••Configure Scheduler
••Configure QoS
14
2.1 Configure the Wireless Parameters
To configure the wireless parameters, go to the Wireless > Wireless Settings page.
For a dual-band EAP, there are two bands: 2.4GHz and 5GHz. The wireless parameters are
separately set on each band. You can click to select a band and configure the
wireless parameters on this band.
15
Before configuring the wireless parameters on each band, check the box to enable 2.4GHz
or 5GHz Wireless Radio. Only when this option is enabled will the wireless radio on 2.4GHz
or 5GHz band works.
Demonstrated with 2.4GHz, the following sections introduce these contents: Configure
SSIDs and Configure Wireless Advanced Settings .
2.1.1 Configure SSIDs
SSID (Service Set Identifier) is used as an identifier for a wireless LAN, and is commonly
called as the “network name“. Clients can find and access the wireless network through
the SSID. For one EAP, you can build up to eight SSIDs per frequency band.
16
Follow the steps below to create an SSID on the EAP:
Tips
You can also click to edit the specific SSID which already exists in the list. And you can click
to delete the SSID in the list.
SSID Broadcast With the option enabled, EAP will broadcast the SSID to the nearby
hosts, so that those hosts can find the wireless network identified by
this SSID. If this option is disabled, users must enter the SSID manually
to connect to the EAP.
Security Mode Select the security mode of the wireless network. There are four
options:
None: Clients can access the wireless network without authentication.
Guest Network With this option enabled, guest network will block clients from reaching
any private IP subnet.
Rate Limit With this option enabled, the download and upload rate of each client
which connects to the SSID will be limited to balance bandwidth usage.
You can limit the download and upload rate for some specific clients by
configuring rate limit in client list, refer to View Client Information to
get more details.
Note that the download and upload rate will be limited to the smaller
value if you set the limit value both in SSID and client configuration.
Following is the detailed instructions about how to configure WEP , WPA-Enterprise and
WPA-PSK .
••WEP
WEP (Wired Equivalent Privacy) is a traditional encryption method. It has been proved
that WEP has security flaws and can easily be cracked, so WEP cannot provide effective
17
protection for wireless networks. Since WPA-PSK and WPA-Enterprise are much safer
than WEP, we recommend that you choose WPA-PSK or WPA-Enterprise if your clients
also support them.
Note
WEP is not supported in 802.11n mode or 802.11ac mode. If WEP is applied in 802.11n, 802.11 ac
or 802.11n/ac mixed mode, the clients may not be able to access the wireless network. If WEP is
applied in 802.11b/g/n mode (2.4GHz) or 802.11a/n (5GHz), the EAP may work at a low transmission
rate.
Key Selected Select one key to specify. You can configure four keys at most.
WEP Key Format Select ASCII or Hexadecimal as the WEP key format.
ASCII: With this format selected, the WEP key can be any combination of
keyboard characters of the specified length.
Hexadecimal: With this format selected, the WEP key can be any
combination of hexadecimal digits (0-9, a-f, A-F) with the specified length.
18
Key Value Enter the WEP keys. The length and valid characters are determined by the
key format and key type.
••WPA-Enterprise
19
Encryption Select the Encryption type.
Auto: The default setting is Auto and the EAP will select TKIP or AES
automatically based on the client device’s request.
TKIP: Temporal Key Integrity Protocol. TKIP is not supported in
802.11n mode, 802.11ac mode or 802.11n/ac mixed mode. If TKIP is
applied in 802.11n, 802.11 ac or 802.11n/ac mixed mode, the clients
may not be able to access the wireless network. If TKIP is applied in
11b/g/n mode (2.4GHz) or 11a/n mode(5GHz), the device may work at
a low transmission rate.
AES: Advanced Encryption Standard. It is securer than TKIP.
RADIUS Password Enter the shared secret key of the RADIUS server.
Accounting Server Enter the shared secret key of the accounting server.
Password
Interim Update With this option enabled, you can specify the duration between
accounting information updates. By default, the function is disabled.
Enter the appropriate duration between updates for EAPs in Interim
Update Interval.
Interim Update With Interim Update enabled, specify the appropriate duration
Interval between updates for EAPs. The default duration is 600 seconds.
Group Key Update Specify an update period of the encryption key. The update period
Period instructs how often the EAP should change the encryption key. 0
means that the encryption key does not change at anytime.
20
••WPA-PSK
Group Key Specify an update period of the encryption key. The update period instructs
Update Period how often the EAP should change the encryption key. 0 means that the
encryption key does not change at anytime.
21
2.1.2 Configure Wireless Advanced Settings
Proper wireless parameters can improve the performance of your wireless network.
This section introduces how to configure the advanced wireless parameters of the EAP,
including Radio Setting , Load Balance , Airtime Fairness and More Settings.
Radio Setting
Radio settings directly control the behavior of the radio in the EAP and its interaction with
the physical medium; that is, how and what type of signal the EAP emits.
Select the frequency band (2.4GHz/5GHz) and configure the following parameters.
Wireless Mode Select the IEEE 802.11 mode the radio uses.
When the frequency of 2.4GHz is selected, 802.11b/g/n mixed, 802.11b/g
mixed, and 802.11n only modes are available:
802.11b/g/n mixed: All of 802.11b, 802.11g, and 802.11n clients operating
in the 2.4GHz frequency can connect to the EAP. We recommend you
select the 802.11b/g/n mixed mode.
802.11b/g mixed: Both 802.11b and 802.11g clients can connect to the
EAP.
802.11n only: Only 802.11n clients can connect to the EAP.
When the frequency of 5GHz is selected, 802.11 a/n/ac mixed, 802.11n/ac
mixed and 802.11 ac only are available:
802.11a/n/ac mixed: All of 802.11a, 802.11n clients and 802.11ac clients
operating in the 5GHz frequency can connect to the EAP.
802.11n/ac mixed: Both 802.11n clients and 802.11ac clients operating in
the 5GHz frequency can connect to the EAP.
802.11ac only: Only 802.11ac clients can connect to the EAP.
22
Channel Width Select the channel width of the EAP. The available options differ among
different EAPs.
For some EAPs, available options include 20MHz, 40MHz and 20/40MHz.
For other EAPs, available options include 20MHz, 40MHz, 80MHz and
20/40/80MHz.
When the radio mode includes 802.11n, we recommend you set the channel
bandwidth to 20/40 MHz or 20/40/80MHz to improve the transmission
speed. However, you may choose a lower bandwidth due to the following
reasons:
••To increase the available number of channels within the limited total
bandwidth.
••To avoid interference from overlapping channels occupied by other
devices in the environment.
••Lower bandwidth can concentrate higher transmit power, increasing
stability of wireless links over long distances.
Channel Limit Check the box to enable the Channel Limit function. With this function
enabled, the wireless frequency 5150MHz~5350MHz will be disabled. This
function can influence the available options in Channel.
This feature is only available for 5GHz wireless configuration of EAP225-
Outdoor.
Channel Select the channel used by the EAP. For example, 1/2412MHz means that
the channel is 1 and the frequency is 2412MHz.
By default, the channel is automatically selected, and we recommend that
you keep the default setting.
23
Tx Power (EIRP) Specify the transmit power value.
If this value is set to be larger than the maximum transmit power that is
allowed by the local regulation, the regulated maximum transmit power will
be applied in the actual situation.
Note: In most cases, it is unnecessary to use the maximum transmit power.
Specifying a larger transmit power than needed may cause interference to
the neighborhood. Also it consumes more power and reduces longevity of
the device.
Load Balance
With the Load Balance feature, you can limit the maximum number of clients who can
access the EAP. In this way, you can achieve rational use of network resources.
1. Click to choose a frequency band on which the load balance feature will
take effect.
3. Specify the maximum number of clients who can connect to the EAP at the same time.
While the number of connected clients has reached the limit and there are more clients
requesting to access the network, the EAP will disconnect those with weaker signals.
4. Click Save.
Airtime Fairness
Note
EAP225_V3, EAP225-Outdoor_V1, EAP245_V3 support this feature.
With Airtime Fairness enabled, each client connected to the EAP can get the same amount
of time to transmit data, avoiding low-data-rate clients to occupy too much network
bandwidth.
24
Compared with the relatively new client devices, some legacy client devices support
slower wireless rate. If they communicate with the same EAP, the slower clients take more
time to transmit and receive data compared with the faster clients. As a result, the overall
wireless throughput of the network decreases.
Therefore we recommend you check the box to enable this function under multi-
rate wireless networks. In this way, the faster clients can get more time for the data
transmission and the network overall throughput can be improved.
Note that 50 wireless clients at most can connect to the EAP in 2.4GHz band when this
function enabled on EAP245_V3, EAP225_V3 and EAP225-Outdoor_V1.
More Settings
Proper wireless parameters can improve the network’s stability, reliability and
communication efficiency. The advanced wireless parameters consist of Fast Roaming,
Beacon Interval, DTIM Period, RTS Threshold, and Fragmentation Threshold.
Beacon Interval Beacons are transmitted periodically by the EAP to announce the presence
of a wireless network for the clients. Beacon Interval determines the time
interval of the beacons sent by the EAP.
You can specify a value between 40 and 100ms. The default is 100ms.
25
DTIM Period The DTIM (Delivery Traffic Indication Message) is contained in some
Beacon frames. It indicates whether the EAP has buffered data for client
devices. The DTIM Period indicates how often the clients served by this
EAP should check for buffered data still on the EAP awaiting pickup.
You can specify the value between 1-255 Beacon Intervals. The default
value is 1, indicating that clients check for buffered data at every beacon.
An excessive DTIM interval may reduce the performance of multicast
applications, so we recommend you keep the default value.
RTS Threshold RTS/CTS (Request to Send/Clear to Send) is used to improve the data
transmission efficiency of the network with hidden nodes, especially when
there are lots of large packets to be transmitted.
When the size of a data packet is larger than the RTS Threshold, the RTS/
CTS mechanism will be activated. With this mechanism activated, before
sending a data packet, the client will send an RTS packet to the EAP to
request data transmitting. And then the EAP will send CTS packet to inform
other clients to delay their data transmitting. In this way, packet collisions
can be avoided.
For a busy network with hidden nodes, a low threshold value will help
reduce interference and packet collisions. But for a not-so-busy network, a
too low threshold value will cause bandwidth wasting and reduce the data
throughput. The recommended and default value is 2347 bytes.
Fragmentation The fragmentation function can limit the size of packets transmitted over
Threshold the network. If the size of a packet exceeds the Fragmentation Threshold,
the fragmentation function is activated and the packet will be fragmented
into several packets.
Fragmentation helps improve network performance if properly configured.
However, a too low fragmentation threshold may result in poor wireless
performance caused by the extra work of dividing up and reassembling
of frames and increased message traffic. The recommended and default
value is 2346 bytes.
In this module, you can also configure Free Authentication Policy, which allows the specific
clients to access the specific network resources without authentication.
26
To configure portal authentication, go to the Wireless > Portal page.
Configure Portal
Three portal authentication types are available: No Authentication , Local Password
and External RADIUS Server . The following sections introduce how to configure each
authentication type.
27
••No Authentication
With this authentication type configured, clients can pass the authentication and access
the network without providing any login information. They only need to accept the term of
use on the authentication page.
Follow the steps below to configure No Authentication as the portal authentication type:
28
Redirect With this function configured, the newly authenticated client will be
redirected to the specific URL.
Redirect URL With Redirect enabled, you also need to enter the URL in this field. The
newly authenticated client will be redirected to this URL.
Portal Configure the authentication page. Local Web Portal is the only available
Customization option in this authentication type. Enter the title and term of use in the two
boxes.
The EAP uses its built-in web server to provide this authentication page for
clients. To pass the authentication, clients only need to check the box of I
accept the Term of Use and click the Login button.
4. Click Save.
••Local Password
With this authentication type configured, clients are required to provide the correct
password to pass the authentication.
29
Follow the steps below to configure Local Password as the portal authentication type:
Redirect With this function configured, the newly authenticated client will be
redirected to the specific URL.
Redirect URL With Redirect enabled, you also need to enter the URL in this field. The
newly authenticated client will be redirected to this URL.
Portal Configure the authentication page. Local Web Portal is the only available
Customization option is this authentication type. Enter the title and term of use in the two
boxes.
The EAP uses its built-in web server to provide this authentication page
for clients. To pass the authentication, clients need to provide the correct
password in the Password field, check the box of I accept the Term of Use
and click the Login button.
4. Click Save.
30
••External RADIUS Server
If you have a RADIUS server on the network to authenticate the clients, you can select
External Radius Server. Clients need to provide the correct login information to pass the
authentication.
31
Follow the steps below to configure External Radius Server as the portal authentication
type:
2. Build a RADIUS server on the network and make sure that it is reachable by the EAP.
3. Go to the Portal configuration page on the EAP. Select External Radius Server as the
authentication type.
Accounting Server Port Enter the port number of the accounting server.
Accounting Server Enter the shared secret key of the accounting server.
Passsword
Interim Update With this option enabled, you can specify the duration between
accounting information updates. By default, the function is
disabled.
Enter the appropriate duration between updates for EAPs in
Interim Update Interval.
Interim Interval With Interim Update enabled, specify the appropriate duration
between updates for EAPs. The default duration is 600 seconds.
32
Redirect With this function configured, the newly authenticated client will
be redirected to the specific URL.
Redirect URL With Redirect enabled, you also need to enter the URL in this
field. The newly authenticated client will be redirected to this URL.
Portal Customization Configure the authentication page. There are two options: Local
Web Portal and External Web Portal.
4. Click Save.
33
the clients can visit the login page provided by the web portal server and then pass the
subsequent authentication process.
1. In the Free Authentication Policy section, click to load the following page.
2. Configure the following parameters. When all the configured conditions are met, the
client can access the network without authentication.
Source IP Range Specify an IP range with the subnet and mask length. The clients in this
IP range can access the network without authentication.
Leaving the field empty means that clients with any IP address can
access the specific resources.
Destination IP Specify an IP range with the subnet and mask length. The devices in
Range this IP range can be accessed by the clients without authentication.
Leaving the field empty means that all devices in the LAN can be
accessed by the specific clients.
Source MAC Specify the MAC address of the client, who can access the specific
Address resources without authentication.
Leaving the field empty means that clients with any MAC address can
access the specific resources.
34
Destination Port Specify the port number of the service. When using this service, the
clients can access the specific resources without authentication.
Leaving the field empty means that clients can access the specific
resources no matter what service they are using.
Tips
When External Web Portal is configured in the portal configuration, you should set the IP address
and subnet mask of the external web server as the Destination IP Range. As for Source IP Range,
Source MAC Address and Destination Port, you can simply keep them as empty or configure them
according to your actual needs.
To configure VLAN for the wireless network, go to the Wireless > VLAN page.
2. In the VLAN column and select Enable to enable the VLAN function on the SSID.
35
3. Specify the VLAN ID for the wireless network in the VLAN ID column. Every VLAN ID
represents a different VLAN. It supports maximum 8 VLANs per frequency band. The
VLAN ID range is 0 to 4094. 0 is used to disable VLAN tagging.
4. Click Save.
36
Follow the steps below to configure MAC Filtering on this page:
1. In the Settings section, check the box to enable MAC Filtering, and click Save.
2. In the Station MAC Group section, click and the following page will
appear.
1 ) Click and specify a name for the MAC group to be created. Click OK.
You can create up to eight MAC groups.
2 ) Select a MAC group in the group list (the color of the selected one will change to
blue). Click to add group members to the MAC group. Specify
37
the MAC address of the host and click OK. In the same way, you can add more MAC
addresses to the selected MAC group.
3. In the MAC Filtering Association section, configure the filtering rule. For each SSID, you
can select a MAC group in the MAC Group Name column and select the filtering rule
(Allow/Deny) in the Action column. Click Save.
For example, the following configuration means that the hosts in Group 2 are denied to
access the SSID SSID-1 on the 2.4GHz band and allowed to access the SSID SSID-2 on
the 5GHz band.
38
To configure Scheduler, go to the Wireless > Scheduler page.
1. In the Settings section, check the box to enable Scheduler and select the Association
Mode. There are two modes: Associated with SSID (the scheduler profile will be applied
to the specific SSID) and Associated with AP (the profile will be applied to all SSIDs on
the EAP). Then click Save.
39
2. In the Scheduler Profile Configuration section, click and the following
page will appear.
1 ) Click and specify a name for the profile to be created. Click OK. You
can create up to eight profiles.
2 ) Select a profile in the list (the color of the selected one will change to blue). Click
to add time range items to the profile. Specify the Day, Start Time and
End Time of the time range, and click OK.
Tips
You can add up to eight time range items for one profile. If there are several time range items in one
profile, the time range of this profile is the sum of all of these time ranges.
40
3. In the Scheduler Association section, configure the scheduler rule. There are two
association modes: Association with SSID and Association with AP . The following
sections introduce how to configure each mode.
If you select Association with SSID in step 1, the Scheduler Association table will
display all the SSIDs on the EAP. For each SSID, you can select a profile in the Profile
Name column and select the scheduler rule (Radio On/Radio Off) in the Action column.
Then click Save.
For example, the following configuration means that during the time range defined in
Profile2, the radio of SSID SSID-1 is on and the radio of SSID SSID-2 is off.
■■Association with AP
If you select Association with AP in step 1, the Scheduler Association table will display
the name and MAC address of the EAP. Select a profile in the Profile Name column and
select the scheduler rule (Radio On/Radio Off) in the Action column. Then click Save.
For example, the following configuration means that during the time range defined in
Profile2, the radio of all SSIDs on the EAP is on.
41
diminished. Band Steering can steer dual-band clients to the 5GHz frequency band which
supports higher transmission rates and more client devices, and thus to greatly improve
the network quality.
Note
Only the dual-band EAP products support Band Steering.
2. Configure the following parameters to balance the clients on both frequency bands:
42
Connection Connection Threshold defines the maximum number of clients
Threshold/Difference connected to the 5GHz band. The value of Connection Threshold
Threshold is from 2 to 40, and the default is 20.
Difference Threshold defines the maximum difference between
the number of clients on the 5GHz band and 2.4GHz band. The
value of Difference Threshold is from 1 to 8, and the default is 4.
When the following two conditions are both met, the EAP prefer to
refuse the connection request on 5GHz band and no longer steer
other clients to the 5GHz band:
1.The number of clients on the 5GHz band reaches the Connection
Threshold value.
2.The difference between the number of clients on the 2.4GHz
band and 5GHz band reaches the Difference Threshold value.
Max Failures If a client repeatedly attempts to associate with the EAP on the
5GHz band and the number of rejections reaches the value of Max
Failures, the EAP will accept the request.
The value is from 0 to 100, and the default is 10.
3. Click Save.
In QoS configuration, you should set parameters on the transmission queues for
different types of wireless traffic and specify minimum and maximum wait time for data
transmission. In normal use, we recommend that you keep the default values.
43
To configure QoS, go to the Wireless > QoS page.
2. Check the box to enable Wi-Fi Multimedia (WMM). With WMM enabled, the EAP uses
the QoS function to guarantee the high priority of the transmission of audio and video
packets.
44
Note
If 802.11n only mode is selected in 2.4GHz (or 802.11n only, 802.11ac only, or 802.11 n/ac mixed
mode selected in 5GHz), the WMM should be enabled. If WMM is disabled, the 802.11n only mode
cannot be selected in 2.4GHz (or 802.11n only, 802.11ac only, or 802.11 n/ac mixed mode in 5GHz).
3. In the AP EDCA Parameters section, configure the AP EDCA ((Enhanced Distributed
Channel Access) parameters. AP EDCA parameters affect traffic flowing from the EAP
to the client station. The following table detailedly explains these parameters.
Queue Displays the transmission queue. By default, the priority from high to
low is Data 0, Data 1, Data 2, and Data 3. The priority may be changed if
you reset the EDCA parameters.
Data 0 (Voice): Highest priority queue, minimum delay. Timesensitive
data such as VoIP and streaming media are automatically sent to this
queue.
Data 1 (Video): High priority queue, minimum delay. Time-sensitive
video data is automatically sent to this queue.
Data 2 (Best Effort): Medium priority queue, medium throughput and
delay. Most traditional IP data is sent to this queue.
Data 3 (Background): Lowest priority queue, high throughput. Bulk data
that requires maximum throughput and is not time-sensitive is sent to
this queue (FTP data, for example).
Arbitration Inter- A wait time for data frames. The wait time is measured in slots. Valid
Frame Space values are from 0 to 15.
Minimum A list to the algorithm that determines the initial random backoff wait
Contention time (window) for retry of a transmission.
Window
This value cannot be higher than the value of Maximum Contention
Window.
45
Maximum The upper limit (in milliseconds) for the doubling of the random backoff
Contention value. This doubling continues until either the data frame is sent or the
Window Maximum Contention Window size is reached.
This value must be higher than the value of Minimum Contention
Window.
Maximum Burst Maximum Burst specifies the maximum burst length allowed for
packet bursts on the wireless network. A packet burst is a collection of
multiple frames transmitted without header information. The decreased
overhead results in higher throughput and better performance.
4. In the Station EDCA Parameters section, configure the station EDCA (Enhanced
Distributed Channel Access) parameters. Station EDCA parameters affect traffic
flowing from the client station to the EAP.
Queue Displays the transmission queue. By default, the priority from high to
low is Data 0, Data 1, Data 2, and Data 3. The priority may be changed if
you reset the EDCA parameters.
Data 0 (Voice): Highest priority queue, minimum delay. Timesensitive
data such as VoIP and streaming media are automatically sent to this
queue.
Data 1 (Video): High priority queue, minimum delay. Time-sensitive
video data is automatically sent to this queue.
Data 2 (Best Effort): Medium priority queue, medium throughput and
delay. Most traditional IP data is sent to this queue.
Data 3 (Background): Lowest priority queue, high throughput. Bulk data
that requires maximum throughput and is not time-sensitive is sent to
this queue (FTP data, for example).
Arbitration Inter- A wait time for data frames. The wait time is measured in slots. Valid
Frame Space values are from 0 to 15.
46
Minimum A list to the algorithm that determines the initial random backoff wait
Contention time (window) for retry of a transmission.
Window
This value cannot be higher than the value of Maximum Contention
Window.
Maximum The upper limit (in milliseconds) for the doubling of the random backoff
Contention value. This doubling continues until either the data frame is sent or the
Window Maximum Contention Window size is reached.
This value must be higher than the value of Minimum Contention
Window.
TXOP Limit The TXOP Limit is a station EDCA parameter and only applies to traffic
flowing from the client station to the EAP.
The Transmission Opportunity (TXOP) is an interval of time, in
milliseconds, when a WME (Wireless Multimedia Extensions) client
station has the right to initiate transmissions onto the wireless medium
(WM) towards the EAP. The valid values are multiples of 32 between 0
and 8192.
5. Choose whether to enable the following two options according to your need.
No Acknowledgment With this option enabled, the EAP would not acknowledge frames
with QosNoAck. No Acknowledgment is recommended if VoIP
phones access the network through the EAP.
6. Click Save.
47
Note
The Rogue AP Detection feature is only used for collecting information of the nearby wireless
network and does not impact the detected APs, no matter what operations you have executed in
this feature.
Detect Rogue APs and Move the Rogue APs to the Trusted AP List
Follow the steps below to detect the nearby APs and move the trusted ones to the Trusted
AP list.
1. In the Settings section, check the box to enable Rogue AP Detection. Click Save.
48
2. In the Detected Rogue AP List section, click .
3. Wait for a few seconds without any operation. After detection is finished, the detected
APs will be displayed in the list.
4. To move the specific AP to the Trusted AP list, click in the Action column. For
example, we move the first two APs in the above Detected Rogue AP list to the Trusted
AP list.
49
5. View the trusted APs in the Trusted AP List section. To move the specific AP back to
the Rogue AP list, you can click in the Action column.
You can import a trusted AP list which records the MAC addresses of the trusted APs. The
AP whose MAC address is in the list will not be detected as a rogue AP.
• Backup the list from a EAP. For details, refer to Backup the Trusted AP List to the
Host .
• Manually create a trusted AP list. Create a txt. file, input the MAC addresses of the
trusted APs in the format XX:XX:XX:XX:XX:XX and use the Space key to separate each
MAC address. Save the file as a cfg file.
2. On this page, check the box to choose Download (PC to AP).
3. Click and select the trusted AP list from your local host.
4. Select the file management mode. Two modes are available: Replace and Merge.
Replace means that the current trusted AP list will be replaced by the one you import.
Merge means that the APs in the imported list will be added to the current list with the
original APs remained.
50
5. Click Save to import the trusted AP list.
You can backup the current trusted AP list and save the backup file to the local host.
1. On this page, check the box to choose Backup (AP to PC).
2. Click Save and the current trusted AP list will be downloaded to your local host as a cfg
file.
51
3 Monitor the Network
This chapter introduces how to monitor the running status and statistics of the wireless
network, including:
52
3.1 Monitor the EAP
To monitor the EAP information, go to the Status > Device page.
Device Name Displays the name of the EAP. The name consists of the product model
followed with the MAC address of the EAP by default.
Firmware Version Displays the current firmware version the EAP. To update the firmware,
you can refer to Update the Firmware .
System Time Displays the current system time. To configure the system time, you can
refer to Configure the System Time .
Uptime Displays how long the EAP has been working since it starts up.
53
CPU Utilization Displays the CPU occupancy. If this value is too high, the EAP may work
abnormally.
Tips
To change the wireless parameters, you can refer to Configure the Wireless Parameters .
54
Monitor the SSIDs
You can monitor the SSID information of the EAP.
Down (Byte) Displays the total download traffic since the SSID starts working.
Up (Byte) Displays the total upload traffic since the SSID starts working.
55
Monitor the radio Settings
You can monitor the radio settings of the EAP. For a dual-band EAP, there are two bands:
2.4GHz and 5GHz. You can click to select a band to view. The following figure posted in the
introduction takes 2.4GHz as an example.
Channel Frequency Displays the channel and frequency which are currently used by the
EAP.
Channel Width Displays the channel width which is currently used by the EAP.
IEEE802.11 Mode Displays the IEEE802.11 protocol currently used by the EAP.
56
The following traffic information of the radio is displayed:
Rx Packets Displays the total number of the received packets on the 2.4GHz/5GHz
band since the EAP starts up.
Tx Packets Displays the total number of the sent packets on the 2.4GHz/5GHz band
since the EAP starts up.
Rx Bytes Displays the total received traffic on the 2.4GHz/5GHz band since the EAP
starts up.
Tx Bytes Displays the total sent traffic on the 2.4GHz/5GHz band since the EAP starts
up.
Rx Dropped Displays the total number of the dropped packets which are received on
Packets the 2.4GHz/5GHz band since the EAP starts up.
Tx Dropped Displays the total number of the dropped packets which are sent on the
Packets 2.4GHz/5GHz band since the EAP starts up.
Rx Errors Displays the total number of error packets which are received on the
2.4GHz/5GHz band since the EAP starts up.
Tx Errors Displays the total number of error packets which are sent on the
2.4GHz/5GHz band since the EAP starts up.
Rx Packets Displays the total number of received packets in the LAN since the EAP
starts up.
Tx Packets Displays the total number of sent packets in the LAN since the EAP starts
up.
Rx Bytes Displays the total received traffic in the LAN since the EAP starts up.
Tx Bytes Displays the total sent traffic in the LAN since the EAP starts up.
57
Rx Dropped Displays the total number of the dropped packets which are received by the
Packets EAP since it starts up.
Tx Dropped Displays the total number of the dropped packets which are sent by the
Packets EAP since it starts up.
Rx Errors Displays the total number of the received error packets since the EAP
starts up.
Tx Errors Displays the total number of the sent error packets since the EAP starts up.
58
View Client Information
There are two types of clients: users and portal authenticated guests. Users are the clients
that connect to the SSID with portal authentication disabled. Guests are the clients that
connect to the SSID with portal authentication enabled.
Click the to select the client types to view the information of the EAP. The
following figure posted in the introduction takes user as an example.
Active Time Displays how long the user has been connected to the SSID.
Up (Byte) Displays the user’s total uploaded traffic to the EAP since the last
connection.
Down (Byte) Displays the user’s total downloaded traffic from the EAP since the last
connection.
RSSI (dBm) Displays the RSSI(Received Signal Strength Indication) of the user.
59
You can execute the corresponding operation to the EAP by clicking an icon in the Action
column.
Click the icon to configure the rate limit of the client to balance
bandwidth usage. Enter the download limit and upload limit and click
OK.
You can limit the download and upload rate for each clients by which
connect to specific SSIDs when configuring SSIDs, refer to Configure
SSIDs to get more details.
Note that the download and upload rate will be limited to the smaller
value if you set the limit value both in SSID and client configuration.
Click the icon to block the access of the client to the network.
Up (Byte) Displays the user’s total uploaded traffic to the EAP since the last
connection.
Down (Byte) Displays the user’s total downloaded traffic from the EAP since the last
connection.
Action You can click the to resume the client's access to the internet.
60
4 Manage the EAP
The EAP provides powerful functions of device management and maintenance. This
chapter introduces how to manage the EAP, including:
••Configure LED
••Configure SSH
••Configure SNMP
61
4.1 Manage the IP Address of the EAP
The IP address of the EAP can be a dynamic IP address assigned by the DHCP server or
a static IP address manually specified by yourself. By default, the EAP gets a dynamic IP
address from the DHCP server. You can also specify a static IP address according to your
needs.
Tips
For detailed introduction about how to find the dynamic IP address of the EAP, refer to Log In via a
wired connection .
To configure the IP address of the EAP, go to the Management > Network page.
62
••Dynamic
If you choose Dynamic as the IP address mode, make sure that there is a reachable
DHCP server on your network and the DHCP sever is properly configured to assign IP
address and the other network parameters to the EAP.
For network stability, you can also configure the fallback IP parameters for the EAP:
DHCP Fallback IP Specify a fallback IP address for the EAP. Make sure that this IP
address is not being used by any other device in the same LAN.
The default DHCP fallback IP is 192.168.0.254.
DHCP Fallback IP MASK Specify the network mask of the fallback IP. The default DHCP
fallback IP mask is 255.255.255.0.
••Static
If you choose Static as the IP address mode, you need to manually specify an IP
address and the related network parameters for the EAP. Make sure that the specified
IP address is not being used by any other device in the same LAN.
63
Configure the IP address and network parameters as the following table shows:
3. Click Save.
On this page, you can view the system logs and configure the way of receiving system
logs.
64
View System Logs
In the Log section, you can click to refresh the logs and view them in the table.
1. Check the corresponding box to enable one or more ways of receiving system logs,
and configure the related parameters. Two ways are available: Auto Mail and Server .
■■Auto Mail
If Auto Mail is configured, system logs will be sent to a specified mailbox. Check the box
to enable the feature and configure the related parameters.
Note
SSL encryption is not currently supported.
65
The following table introduces how to configure these parameters:
Enable If the sender’s mailbox is configured with You can check the box to
Authentication enable mail server authentication. Enter the sender’s username and
password.
Fixed Time If you select Fixed Time, specify a fixed time to send the system log
mails. For example, 08:30 indicates that the mail will be sent at 8:30 am
everyday.
Period Time If you select Period Time, specify a period time to regularly send the
system log mail. For example, 6 indicates that the mail will be sent every
six hours.
■■Server
If Server is configured, system logs will be sent to the specified system log server, and
you can use the syslog software to view the logs on the server.
Enable this feature and enter the IP address and port of the system log server.
More Client Detail Log With the option enabled, the logs of clients will be sent to the
server.
2. Click Save.
66
4.3 Configure Web Server
With the web server, you can log in to the management web page of the EAP. You can
configure the web server parameters of the EAP according to your needs.
Secure Server Port Designate a secure server port for web server in HTTPS mode. By
default the port is 443.
Server Port Designate a server port for web server in HTTP mode. By default the
port is 80.
Session Timeout Set the session timeout. If you do nothing with the web page within
the timeout, the system will log out automatically. You can log in again
if you want to go back to web page.
2. Click Save.
67
To configure Management Access, go to the Management > Management Access page.
3. Click Save.
68
Tips
••You can click to quickly add the MAC address of your current logged-in host, .
••Verify the MAC addresses carefully. Once the settings are saved, only the hosts in the MAC
address list can access the web page of the EAP.
••If you cannot log in to the web page after saving the wrong configuration, you can reset the EAP to
the factory defaults and use the default username and password (both admin) to log in.
2. Specify the VLAN ID of the management VLAN. Only the hosts in the Management
VLAN can log in to the EAP via the Ethernet port.
3. Click Save.
69
4.5 Configure LED
You can turn on or off the LED light of the EAP and flash the LED to locate your device.
Check the box to turn on or turn off the LED light of the EAP, and click Save. To flash the
LED, click Locate. Then the LED will flash for 10 minutes or until the locate button is clicked
again.
70
4.6 Configure Wi-Fi Control (For EAP115-Wall)
EAP115-Wall has an LED/Wi-Fi button on the front panel. With Wi-Fi Control enabled, you
can press the button to turn on or off both of the Wi-Fi and LED at the same time.
Note
You can enable Wi-Fi Control only when the option LED ON/OFF is enabled.
Check the box to enable the PoE feature and click Save.
71
4.8 Configure SSH
If you want to remotely log in to the EAP via SSH, you can deploy an SSH server on your
network and configure the SSH feature on the EAP.
3. Click Save.
72
4.9 Configure SNMP
The EAP can be configured as an SNMP agent and work together with the SNMP manager.
Once the EAP has become an SNMP agent, it is able to receive and process request
messages from the SNMP manager. At present, the EAP supports SNMP v1 and v2c.
To configure the EAP as an SNMP agent, go to the Management > SNMP page.
SysContact Enter the textual identification of the contact person for this managed
node.
Get Source Defines the IP address (for example, 10.10.10.1) for management
systems that can serve as Get Community to read the SNMP information
of this device. The default is 0.0.0.0, which means all hosts can read the
SNMP information of this device.
73
Set Community Set Community has the read and write right of the device’s SNMP
information. Enter the community name that allows read/write access to
the device’s SNMP information. The community name can be considered
a group password. The default setting is private.
Set Source Defines the IP address (for example, 10.10.10.1) for management
systems that can serve as Set Community to read and write the SNMP
information of this device. The default is 0.0.0.0, which means all hosts
can read and write the SNMP information of this device.
3. Click Save.
Note
Defining community can allow management systems in the same community to communicate
with the SNMP Agent. The community name can be seen as the shared password of the network
hosts group. Thus, for the security, we recommend that modify the default community name before
enabling the SNMP Agent service. If the field of community is blank, the SNMP Agent will not
respond to any community name.
74
5 Configure the System
This chapter introduces how to configure the system of the EAP, including:
75
5.1 Configure the User Account
Every EAP has a user account, which is used to log in to the management page of the EAP.
When you start the EAP at the first time, the username and password of the user account
are both admin. After the first login, the system will require you to set a new username and
a new password for the user account. And then you can use the new user account to log in
to the EAP. Also, you can change your user account as needed.
Tips
Please remember your user account well. If you forget it, reset the EAP to the factory defaults and
log in with the default user account (username and password are both admin).
Follow the steps below to change your user account on this page:
1. Enter the old username and old password of your user account.
2. Specify a new username and a new password for your user account. The system
will automatically detect the strength of your entered password. For security, we
recommend that you set a password with high strength.
4. Click Save.
76
To configure the system time, go to the System > Time Settings page.
The following two sections introduce how to configure the basic system time settings and
the Daylight Saving Time feature.
Determine the way of setting the system time and follow the steps below to complete the
configurations:
77
••Set the System Time Manually
1. Configure the following three options on the page: Time Zone, Date and Time.
Time Zone Select your time zone from the drop-down list. Here GMT means
Greenwich Mean Time.
Date Specify the current date in the format MM/DD/YYYY. MM means month,
DD means day and YYYY means year.
For example: 06/01/2017.
Time Specify the current time in the format HH/MM/SS. HH means hour, MM
means minute and SS means second.
It uses 24-hour system time. For example: 14:36:21.
2. Click Save.
Note
The system time set manually will be lost after the EAP is rebooted.
To get the system time from an NTP server, follow the steps below:
1. Build an NTP server on your network and make sure that it is reachable by the EAP. Or
you can simply find an NTP server on the internet and get its IP address.
Note
If you use an NTP server on the internet, make sure that the gateway address is set correctly on the
EAP. Otherwise, the EAP cannot get the system time from the NTP server successfully. To set the
gateway address, refer to Configure the Wireless Parameters.
2. Specify the NTP server for the EAP. If you have two NTP servers, you can set one of
them as the primary NTP server, and the other as the secondary NTP server. Once the
primary NTP server is down, the EAP can get the system time from the secondary NTP
server.
3. Click the button and the acquired system time will be displayed in the Date
and Time fields.
78
4. Click Save.
To synchronize the system time with the clock of your currently logged-in host,
follow the steps below:
1. Click the button and the synchronized system time will be displayed
in the Date and Time fields.
2. Click Save.
Note
The system time synchronized with PC’s clock will be lost after the EAP is rebooted.
2. Select the mode of daylight saving time. Three modes are available: Predefined Mode,
Recurring Mode and Date Mode.
■■Predefined Mode
If you select Predefined Mode, choose your region from the drop-down list and the EAP
will use the predefined daylight saving time of the selected region.
79
There are four regions provided: USA, European, Austrilia and New Zealand. The
following table introduces the predefined daylight saving time of each region.
USA From 2: 00 a.m. on the Second Sunday in March to 2:00 a.m. on the First
Sunday in November.
European From 1: 00 a.m. on the Last Sunday in March to 1:00 a.m. on the Last
Sunday in October.
Australia From 2:00 a.m. on the First Sunday in October to 3:00 a.m. on the First
Sunday in April.
New Zealand From 2: 00 a.m. on the Last Sunday in September to 3:00 a.m. on the
First Sunday in April.
■■Recurring Mode
If you select Recurring Mode, manually specify a cycle time range for the daylight saving
time of the EAP. This configuration will be used every year.
The following table introduces how to configure the cycle time range.
Time Offset Specify the time to set the clock forward by.
Start Specify the start time of daylight saving time. The interval between the
start time and end time should be more than 1 day and less than 1 year
(365 days).
End Specify the end time of daylight saving time. The interval between the
start time and end time should be more than 1 day and less than 1 year
(365 days).
80
■■Date Mode
If you select Date Mode, manually specify an absolute time range for the daylight saving
time of the EAP. This configuration will be used only once.
The following table introduces how to configure the absolute time range.
Time Offset Specify the time to set the clock forward by.
Start Specify the start time of daylight saving time. The interval between the
start time and end time should be more than 1 day and less than 1 year
(365 days).
End Specify the end time of daylight saving time. The interval between the
start time and end time should be more than 1 day and less than 1 year
(365 days).
4. Click Save.
To reboot and reset the EAP, go to the System > Reboot&Reset page.
• To reboot the EAP, click the button , and the EAP will be rebooted automatically.
Please wait without any operation.
81
• To reset the EAP, click the button , and the EAP will be reset to the factory
defaults automatically. Please wait without any operation.
Note
After reset, all the current configuration of the EAP will be lost. We recommend that you check
whether you have any configuration that needs to be backed up before resetting the EAP.
To backup and restore the configuration, go to the System > Backup&Restore page.
• To backup the configuration, click the button in the Backup section, and the
backup file will be saved to the host automatically.
• To restore the configuration, click the button in the Restore section and
choose the backup file from the host. Then click the button to restore the
configuration.
82
To update the firmware, go to the System > Firmware Update page.
1. Go to our website https://www.tp-link.com and search your EAP model. Download the
proper firmware file on the support page of the EAP.
2. Click the button , locate and choose the correct firmware file from your host.
3. Click the button to update the firmware of the EAP. After updated, the EAP will
be rebooted automatically.
Note
The update process takes several minutes. To avoid damage to the EAP, please wait without any
operation until the update is finished.
83
6 Application Example
This chapter provides an application example about how to establish and manage a EAP
wireless network:
A restaurant wants to provide the wireless internet access for the employees and guests.
The restaurant now has a router, a switch, a dual-band EAP and a computer. Follow the
steps below to establish the wireless network:
84
6.1 Determine the Network Requirements
Before starting to build the network, we need to first analyze and determine the network
requirements. In this restaurant example, the network requirements are as follows:
• On both 2.4GHz and 5GHz bands, there are two SSIDs needed: one for the restaurant
employees and one for the guests.
• In order to advertise the restaurant, the Portal feature needs to be configured on the
SSIDs for the guests. In this way, the guests who have passed the portal authentication
will be redirected to the restaurant’s official website http://www.restaurant1.com.
• The employees of the restaurant can use the correct password to access the internet
and do not need to pass the portal authentication. For security, the SSIDs for the
employees should be encrypted with WPA2-PSK.
• To reduce power consumption, the Scheduler feature needs to be configured. The radio
should operate only during the working time (9:00 am to 22:00 pm).
Management Host
EAP
• The router is the gateway of the network and acts as a DHCP server to assign dynamic
IP addresses to the management host, EAP and clients. The LAN IP of the router is
192.168.88.1/24.
• Connect the management host and the EAP to the switch. The IP address mode of
the management host and EAP is dynamic, which means that they will get dynamic IP
addresses from the router.
Tips
If the router has more than one LAN port, we can also respectively connect the management host
and the EAP to the LAN ports of the router.
85
6.3 Log in to the EAP
After building the network topology, follow the steps below to log in to the web page of the
EAP:
1. On the management host, launch the web browser and enter “192.168.88.1” in the
address bar. Then log in to the router and find the IP address of the EAP. As the
following figure shows, the IP address of the EAP is 192.168.88.101.
2. Enter “192.168.88.101” in the address bar to load the login page of the EAP. Type the
default username and password (both admin) in the two fields and click LOGIN.
3. In the pop-up window, specify a new username and a new password for the user
account. Click Next.
86
6.4 Configure the EAP
To achieve the network requirements in this application example, we need to Configure
SSIDs , Configure Portal Authentication and Configure Scheduler .
Configure SSIDs
1. After Logging in to EAP, follow the step-by-step instructions to complete the basic
configurations of creating SSIDs. Configure the SSID as “employee_2.4GHz” and
“employee_5GHz”, specify the Password as “restaurant123abc“. Click Save.
2. Go to the Wireless > Wireless Settings page. Create SSIDs for guests on 2.4GHz. Click
to add a new SSID.
87
3. The following page will appear. Configure this SSID as “guest_2.4GHz“, keep the
Security Mode as “None” and check the box to enable the Portal feature for this SSID.
Click OK.
4. Click to enter the configuration page for the 5GHz band. Similarly to
the configurations for the 2.4GHz band, configure another SSID for the guests on the
5GHz band.
88
2. Configure the portal feature as the following figure shows.
1 ) Select the SSIDs for the guests on which the portal will take effect.
2 ) Select the Authentication Type as “Local Password” and specify the Password as
“restaurant123”.
4 ) Check the box to enable Redirect, and enter the website of the restaurant: http://
www.restaurant1.com.
89
5 ) Configure the authentication page. Specify the title and the term of use. To access
the internet, guests need to enter the correct password in the Password field,
accept the Term of Use, and click the Login button.
3. Click Save.
Configure Scheduler
Follow the steps below to schedule the radio to operate only during the working time (9:00
am to 22:00 pm).
2. In the Settings section, check the box to enable Scheduler, and select the Association
Mode as “Associated with AP“. Click Save.
1 ) The following page will appear. Click and specify the profile name as
“worktime”. Click OK.
90
2 ) Choose the newly added profile “worktime”, and click . Then the item
configuraiton page will appear. Specify the time range as everyday 9:00 to 22:00.
Click OK.
4. In the Scheduler Association section, select “worktime“ in the Profile Name column
and select “Radio On” in the Action column. Click Save.
• To test the SSIDs for the employees, follow the steps below:
91
• To test the SSIDs for the guests, follow the steps below:
3 ) The default web browser on the device will pop up and the authentication page will
appear. Enter the password “restaurant123”, check the box to accept the term of
use, and click the LOGIN button.
Tips
Generally, the web browser pops up automatically. But if the web browser does not pop up, we
can manually launch the web browser and visit any http website. Then the authentication page will
appear.
92
4 ) If the network is working normally, we will be redirected to the website of the
restaurant: http://www.restaurant1.com.
93
Appendix: Omada App
Omada app is a mobile application designed for Omada series EAP products. It allows you
to conveniently manage and monitor your network.
This appendix introduces how to use Omada app to manage your network and includes
the following sections:
94
1 Install Omada App on the Mobile Device
Omada app runs on iOS and Android devices, such as smart phones and tablets. Launch
the Apple App Store (iOS) or Google Play store (Android) and search “TP-Link Omada” or
simply scan the QR code to download and install the app.
or
Refer to the topology below, make sure that the following requirements have been met:
• An Ethernet connection from your Omada EAP to the LAN with DHCP service.
• The supported firmware version of the EAP. EAP245, EAP225, EAP115, EAP110,
EAP225-Outdoor, EAP110-Outdoor, EAP115-Wall and EAP225-Wall are currently
supported. To check the firmware versions of the supported EAPs, please refer to www.
tp-link.com/omada_compatibility_list .
EAP
Internet Router
Mobile Device Installed
with Omada App
EAP
Follow the steps below to manage your network via Omada app in standalone mode. The
following page is exampled with the iOS version of the app. The Android version is similar.
95
1. Connect your mobile device to 3. Tap on the EAP appearing on the
the EAP by using the default SSID page. Set a new username and
(format: TP-Link 2.4GHz/5GHz_ password for your login account of
XXXXXX) printed on the label. the EAP.
2. L a u n c h t h e O m a d a a p p , t a p
Standalone APs and wait for the
EAP to be discovered.
Note
The settings will take effect after several
minutes. For operation system differences,
the wireless network connection will be
different. Generally the mobile device will
join the new wireless network automatically
when the SSID of the EAP is changed. If it
doesn’t, connect the mobile device to the
Tips new SSID manually.
All the EAPs in the same subnet will be
discovered by Omada app and shown on
the page. You can tap the discovered EAP
to configure directly.
96
5. You can view the name of the EAP
and other information including
wireless parameters and clients.
And you can tap to change the
settings of radio, SSID and device
account.
Tips
••Omada app is designed to help you
quickly configure some basic settings.
Fo r a d va n c e d f u n c t i o n s , yo u c a n
configure them on the web page of the
EAP.
••In standalone mode, only one user is
allowed to log in to the management
page of the EAP at the same time. Thus
the management web page of the EAP
cannot be logged in to when using the
Omada app and vice versa. Also only
one user can log in to the EAP via Omada
app.
97
FCC Compliance Information Statement
T090060-2B1(For EAP115)
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: http://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: [email protected]
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
•• Reorient or relocate the receiving antenna.
•• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
98
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user’s
authority to operate the equipment.
99
FCC Compliance Information Statement
•• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
We, TP-Link USA Corporation, has determined that the equipment shown as above has
been shown to comply with the applicable technical standards, FCC part 15. There is no
unauthorized change is made in the equipment and the equipment is properly maintained
and operated.
Issue Date:2019-04-22
CE Mark Warning
This is a class B product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and
other relevant provisions of directives 2014/53/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce.
RF Exposure Information
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of
exposure of the general public to electromagnetic fields by way of health protection.
The device complies with RF specifications when the device used at 20 cm from your body.
For EAP225-Outdoor:
This radio transmitter (IC: 8853A-EAP225OD / Model: EAP225-Outdoor) has been approved
by Industry Canada to operate with the antenna types listed below with the maximum
permissible gain indicated. Antenna types not included in this list below, having a gain greater
than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 8853A-EAP225OD / Model: EAP225-Outdoor) a été approuvé
par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous
et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste ci-
dessous et dont le gain est supérieur au gain maximal indiqué, sont strictement interdits
pour l'exploitation de l'émetteur.
Caution (EAP225/EAP245/EAP225-Outdoor/EAP225-Wall)
1) The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems;
2) For devices with detachable antenna(s), the maximum antenna gain permitted for devices
in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still
complies with the e.i.r.p. limit; (For EAP225-Outdoor only)
DFS (Dynamic Frequency Selection) products that operate in the bands 5250- 5350 MHz,
5470-5600MHz, and 5650-5725MHz. (For EAP245 and EAP225-Outdoor).
Avertissement
1) Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux;
2) Le gain maximal d'antenne permis pour les dispositifs avec antenne(s) amovible(s) utilisant
les bandes 5250-5350 MHz et 5470-5725 MHz doit se conformer à la limitation P.I.R.E.; (For
EAP225-Outdoor Only)
Les produits utilisant la technique d'atténuation DFS (sélection dynamique des fréquences)
sur les bandes 5250- 5350 MHz, 5470-5600MHz et 5650-5725MHz.
EAP110/EAP115/EAP225/EAP245/ 20 cm
EAP115-Wall/EAP110-Outdoor/
EAP225-Outdoor/EAP225-Wall
Safety Information
When product has power button, the power button is one of the way to shut off the product;
When there is no power button, the only way to completely shut off power is to disconnect
the product or the power adapter from the power source.
•• Keep the device away from water, fire, humidity or hot environments.
•• Do not use the device where wireless devices are not allowed.
•• Adapter shall be installed near the equipment and shall be easily accessible.
For EAP110/EAP225/EAP245/EAP110-Outdoor/EAP225-Outdoor:
Use only power supplies which are provided by manufacturer and in the original
packing of this product. If you have any questions, please don’t hesitate to contact us.
NCC Notice
注意!
依據 低功率電波輻射性電機管理辦法
第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變
更頻率、加大功率或變更原設計之特性或功能。
第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通行;經發現有干擾現象時,
應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信規定作業之無線電信。
低功率射頻電機需忍受合法通信或工業、科學以及醫療用電波輻射性電機設備之干擾。
針對EAP225/EAP245/EAP225-Wall/EAP225-Outdoor:
4.7.9.1應避免影響附近雷達系統之操作。
4.7.9.2高增益指向性天線只得應用於固定式點對點系統。
BSMI Notice
安全諮詢及注意事項
·請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
·清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
·注意防潮,請勿將水或其他液體潑灑到本產品上。
·插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。
·請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。
·請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。
此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者會被
要求採取某些適當的對策。(針對EAP110/110-Outdoor)
限用物質含有情況標示聲明書
限用物質及其化學符號
產品元件名稱 鉛 鎘 汞 六價鉻 多溴聯苯 多溴二苯醚
Pb Cd Hg CrVI PBB PBDE
PCB ○ ○ ○ ○ ○ ○
外殼 ○ ○ ○ ○ ○ ○
電源適配器
(EAP115-Wall/ — ○ ○ ○ ○ ○
EAP225-Wall
excluded)
Symbol Explanation
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic
equipment (WEEE). This means that this product must be handled pursuant to
European directive 2012/19/EU in order to be recycled or dismantled to minimize
its impact on the environment.
User has the choice to give his product to a competent recycling organization or to
the retailer when he buys a new electrical or electronic equipment.
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: http://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: [email protected]
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user’s
authority to operate the equipment.
This is a class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがあります。この場
合には使用者が適切な対策を講ずるよう要求されることがあります。
VCCI-A
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice. is a registered trademark
of TP-Link Technologies Co., Ltd. Other brands and product names are trademarks or
registered trademarks of their respective holders.
No part of the specifications may be reproduced in any form or by any means or used to
make any derivative such as translation, transformation, or adaptation without permission
from TP-Link Technologies Co., Ltd. Copyright © 2019 TP-Link Technologies Co., Ltd.. All
rights reserved.