Jabacus - Wind Load Calculator

The document is a wind load calculator that provides wind load calculations for a building project in Labrador City, Newfoundland, Canada based on the National Building Code of Canada 2010. It calculates external wind pressure and internal wind pressure for different roof slopes and sides of the building based on specified wind speed, terrain exposure, height, and other factors. The results show wind pressures ranging from -2.0 kPa to 1.15 kPa for ultimate and serviceability limit states depending on the building orientation and side.

Uploaded by

harishram123456
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
687 views1 page

Jabacus - Wind Load Calculator

The document is a wind load calculator that provides wind load calculations for a building project in Labrador City, Newfoundland, Canada based on the National Building Code of Canada 2010. It calculates external wind pressure and internal wind pressure for different roof slopes and sides of the building based on specified wind speed, terrain exposure, height, and other factors. The results show wind pressures ranging from -2.0 kPa to 1.15 kPa for ultimate and serviceability limit states depending on the building orientation and side.

Uploaded by

harishram123456
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

12/4/2019 jabacus - Wind Load Calculator

version 0.1.0
Specified Wind Load Figure I-7 (NBC 2010) December 4,
2019
Project: Designer:
Estimation

Climatic Data Factors

Location Location: Labrador City, Newfoundland


Province: Newfoundland q50: 0.4kPa
Importance Factor, ULS: Iw = 1.0 / SLS: Iw = 0.75
Location: Labrador City Roof slope = 30.3 degrees
Ce = (h/10)0.2 = 1.14
Return Period 50 year
External Wind Pressure
Factors
p = Iw*q*Ce*Cg*Cp
Importance factor Load Case A: Winds generally perpendicular to ridge
Iw: Normal Load Case B: Winds generally parallel to ridge
Load Case A Load Case B
Terrain: Open terrain Side CpCg ULS SLS CpCg ULS SLS
Reference height in meters above grade p p p p
height, h: 19 m (kPa) (kPa) (kPa) (kPa)
1 1.05 0.48 0.36 -0.85 -0.39 -0.29
Roof Pitch: 7 /12 1E 1.3 0.59 0.44 -0.9 -0.41 -0.31

Internal pressure Category, Cpi: 2 0.4 0.18 0.14 -1.3 -0.59 -0.44
2E 0.5 0.23 0.17 -2.0 -0.91 -0.68
Category 1: Cpi = -0.15 to 0
3 -0.8 -0.36 -0.27 -0.7 -0.32 -0.24
3E -1 -0.45 -0.34 -1.0 -0.45 -0.34
4 -0.7 -0.32 -0.24 -0.85 -0.39 -0.29
4E -0.9 -0.41 -0.31 -0.9 -0.41 -0.31
5 n/a n/a n/a 0.75 0.34 0.26
5E n/a n/a n/a 1.15 0.52 0.39
6 n/a n/a n/a -0.55 -0.25 -0.19
6E n/a n/a n/a -0.8 -0.36 -0.27

Internal Wind Pressure


Cgi = 2 Cpi = -0.15 to 0
pi = Iw*q*Ce*Cgi*Cpi

ULS: pi = -0.14kPa to 0kPa


SLS: pi = -0.1kPa to 0kPa

By using Jabacus or information derived from this Service, you have agreed to the Terms of Service (../../terms.php).
This information must be read or used in conjunction with Part 4 of the NBC 2010. In the event of discrepancies, Part 4 of the NBC
2010 shall govern.