////// TRACTION POWER SYSTEMS

ESTRA-MIU10
Isolated amplifiers for current measurement
Type MIU10
GENERAL INFORMATION
APPLICATION
The MIU10 amplifier is suitable for measuring high DC
currents in power distribution systems for public transport
networks.
The MIU10 measuring equipment, with its high voltage
isolation, ensures safety for the equipment and for the
personnel.

MAIN FEATURES
The housing width is 22.5 mm.
The devices isolate and transmit input voltages in the
range of ± 60 mV ... ± 5 V.
The individual measurement ranges are calibrated.
The broad-range power supply operates from 24 to 230 V
AC/DC.

/// ADJUSTABLE VERSION


The working voltage for basic insulation (overvoltage
category III, pollution degree 2) is 2.2 kV / 10 kV dielectric
isolation. The 16 measurement ranges are selected using
an insulated rotary coding switch and/or by reconnecting
the output lines. Preselection is done at factory, according
to the substation specifications.

/// FIXED VERSION (3 KV)


The working voltage for basic insulation (overvoltage
category III, pollution degree 2) is 3.6 kV / 15 kV dielectric
isolation. Available outputs signals: ± 5 V, ± 20 mA or 4 ...
20 mA. The configuration is made only in the factory.

MAIN BENEFITS
MAIN BENEFITS
DD Wide supply voltage range.
DD Low non-linearity error.
DD Very high immunity.
DD High galvanic isolation, up to 15 kV (50 Hz, 1 min).
DD Compact solution.
DD No external protection necessary (fuseless solution).

2 ESTRA-MIU10/Isolatedamplifiersforcurrentmeasurement-TypeMIU10
MAIN CHARACTERISTICS
TECHNICAL DATA
Supply voltage 24 ... 230 V AC/DC -20% / +10%
Input sensitivity ± 60, 90, 150, 300, 500 mV, 5 V
Output voltage Us nom ± 5 V
Output current Is nom ± 20 mA or Is 4...20 mA (if Input = 0, Is = 12 mA)
RLmax = 600 ohms
Error on gain and non-linearity Less than ± 0.1%
< 50 ppm/K full scale
Cut off frequency (-3 dB) > 5 kHz
Voltage consumption < 5 VA
Residual ripple < 10 mVeff
Galvanic isolation EN 50124-1 3-port isolation between input, output and power supply
Operating temperature -25 to +85 °C
Galvanic isolation, input 10 kVAC 50 Hz 1 min (with 16 settings)
against output 15 kVAC 50 Hz 1 min (with fixed setting)
EMC standards EN 50121-5 (when mounted in a cubicle)
EN 61326 class B (standard for isolators)

MECHANICAL DATA
Dimensions (H x W x D) 90 x 22.5 x 118 mm
Weight 180 grams
Sealing IP40 (housing)
Mounting DIN rail

TYPE DESIGNATION

• Standard version with setting selection: SG811410P00001.


• Fixed setting version: upon request.
For more technical information, please refer to the instruction manual.

ESTRA-MIU10/Isolatedamplifiersforcurrentmeasurement-TypeMIU10 3
Sécheron SA www.secheron.com

9.18 Rue du Pré-Bouvier 25 Tel: +41 (0)22 739 41 11


02-0
BEN_C 1242 Satigny - Geneva Fax: +41 (0)22 739 48 11
13841
SG8 CH-Switzerland [email protected]

This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product,
whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser’s responsibility to inform himself, no matter what the circumstances, of
the product’s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our “General Delivery Conditions”.
Copyright© 2018 Sécheron SA

You might also like