0% found this document useful (0 votes)
269 views20 pages

Design of Column&Wall Footing

This document summarizes the design of interior and exterior column footings and a wall footing. For the interior column footing, the dimensions are 2m x 2m with 11 #20 reinforcing bars at 180mm spacing. Punching and shear checks show the footing is adequate. The exterior column footing has similar dimensions and reinforcement. The wall footing specifies a concrete compressive strength and steel yield strength, but provides no other design details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
269 views20 pages

Design of Column&Wall Footing

This document summarizes the design of interior and exterior column footings and a wall footing. For the interior column footing, the dimensions are 2m x 2m with 11 #20 reinforcing bars at 180mm spacing. Punching and shear checks show the footing is adequate. The exterior column footing has similar dimensions and reinforcement. The wall footing specifies a concrete compressive strength and steel yield strength, but provides no other design details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 20

DESIGN OF COLUMN FOOTING

(INTERIOR)

DESIGN CRITERIA:

fy = 276 MPa

f’c = 20.7 MPa

q a = 150 kPa ( allowable soil pressure )

ɣc = 23.54 kN/m³ ( Unit Weight of Concrete )

ɣs = 17.5 kN/m³ ( Unit Weight of Steel )

Column size = 400x400mm

Loads

P DL = Reaction due to Dead Load + Wt. of column + Wt. of column(10%)

= 60.723kN + 48.731kN + 88.843kN + 74.956kN + (23.54kN/m³)(0.4m)(0.4m)

(8.4m) + (23.54kN/m³)(0.4m)(0.4m)(8.4m)(0.1)

= 308.05 kN

P¿ = Reaction due to Live Load

= (58.65+25.83+17.943+23.876) kN
= 126.299 kN

Assume:

h c = 0.4m (depth of concrete)

h s = 1.4m (depth of soil above the footing)

Solve for SOIL UNFACTORED LOAD (P)

P = P DL + P¿

P = 308.05Kn+126.299kN

= 434.349kN

Solve for EFFECTIVE SOIL BEARING CAPACITY( q e)

q e = q a - h c (ɣ c ) - h s ¿ ¿ )

= 150kPa – (0.90)(23.54kN/m³) – (1.4m)(17.5kN/m³)

= 116.0841kPa

Solving for the area of footing:

P
A ftg =
qe

439.349 kN
=
116.084 kN /m²
= 3.74 m² or 3.8 m²

L² = 3.8 m²

L = 1.95 m say 2.0 m

FOOTING DIMENSION = 2m by 2m

Area = 4m²

Solve for SOIL FACTORED LOAD ( PU )

Case 1: PU = 1.4 P DL

= 1.4(308.05kN)

= 431.27kN

Case 2: PU = 1.2 P DL+1.6P¿

= 1.2(308.05kN)+1.6(126.299kN)

= 571.74 kN

Case 2 governs; PU = 571.74kN

Computing for the Factored Upward Pressure

PU
qU =
A ftg

571.75 kN
=
4m²

= 142kN/m² = 0.142 MPa


Use 20mmØ bar with 70mm cc

Ø
d = t – cc - = 400mm – 70mm –20/2mm = 320 mm
2

FAILURE MODES:

a. Based on two-way or punching shear

A shaded = (2mx2m) – (0.72m)(0.72m)

= 3.482m = 3482000 mm

vu = q u ( A shaded)

= 0.142MPa(3482000mm)

= 494.444kN

v c = ⅙ √ f ' c bd

= ⅙ √20.7 MPa(4)(400mm+320mm)

= 698.84kN

v c> vu therefore, the section is safe.

ɸv c = 0.75(⅙) √ f ' cbd

= 0.75(698.84kN)

= 524.13kN

ɸv c > vu , therefore it is safe for punching.


b. Based in Wide-Beam Shear

q u = 0.142MPa

d = 320mm

vup = vu A

= 0.142MPa(800mm-320mm)(2000mm)

= 136.32kN

v c = ⅙ √ f ' c bd

= ⅙ √20.7 MPa(2000mm)(320mm)

= 485.3kN

v c> vu . Therefore, the section is safe.

Solving for the reinforcement:

M u = q u(X)(L)(X/2)

= 0.142MPa(800)(2000)(800/2)

= 90.88 kN.m

Mu
Rn =
ɸbd

90.88 kN . m
=
0.90(2000)(3202 )

= 0.493 MPa
0.85 f ' c 2 Rn
ρ=
fy √
(1− 1− '
0.85 f c
)

0.85(20.7 MPa) 2(0.493 MPa)


=
276 MPa
(1− 1−

0.85(20.7 MPa)
)

= 0.0018

ρmin = 1.4/fy = 1.4/276MPa = 0.00507

Use ρmin = 0.00507

Computing for Area of steel:

A s= ρmin bd

= 0.00507(2000mm)(320mm)

= 3244.8mm²

Required number of steel bars:

Using 20mmØ bar ( Ab =314.16mm²)

As 3244.8 mm ²
N= = = 10.32 or say 11 pcs.
Ab 314.16 mm ²

Solve for spacing:

Ab
S= (2000mm)
As

314.16 mm ²
= (2000mm) = 193.54 mm
3244.8 mm ²

Adjust to 180mm spacing.


Use 11 – 20mm Ø bars spaced at 180 mm o.c.

Check for Development length

From Section 5.12.2 of the code, for 32mm bar and smaller and deformed wires,

0.02 A b fy
Ld =
√f ' c

0.02(314.16 mm 2 )(276 MPa)


=
√ 20.7 MPa

= 381.16 say 400mm

Ld = 0.06dbfy

= 0.06(20mm)(276MPa)

= 331 say 350 mm

Minimum area of dowel or extension bars by the code.

A = 0.005(400mmx400mm)

= 800mm²

Use 2m x 2m footing with an effective depth of 320 mm.


DESIGN OF COLUMN FOOTING

(EXTERIOR)

DESIGN CRITERIA:

fy = 276 MPa

f’c = 20.7 MPa

q a = 150 kPa ( allowable soil pressure )

ɣc = 23.54 kN/m³ ( Unit Weight of Concrete )

ɣs = 17.5 kN/m³ ( Unit Weight of Steel )

Column size = 400x400mm

Loads

P DL = Reaction due to Dead Load + Wt. of column + Wt. of column(10%)


= 126.610kN + 88.483kN + 32.016kN + 60.137kN + (23.54kN/m³)(0.4m)(0.4m)

(8.4m) + (23.54kN/m³)(0.4m)(0.4m)(8.4m)(0.1)

= 342.09kN

P¿ = Reaction due to Live Load

= (10.451+13.921+30.180+11.626) kN

= 66.18kN

Assume:

h c = 0.4m (depth of concrete)

h s = 1.4m (depth of soil above the footing)

Solve for SOIL UNFACTORED LOAD (P)

P = P DL + P¿

P = 342.09kN+66.18kN

= 408.27kN

Solve for EFFECTIVE SOIL BEARING CAPACITY( q e)

q e = q a - h c (ɣ c ) - h s ¿ ¿ )

= 150kPa – (0.40)(23.54kN/m³) – (1.4m)(17.5kN/m³)


= 116.0841kPa

Solving for the area of footing:

P
A ftg =
qe

408.27 kN
=
116.084 kN /m²

= 3.517 m² or 3.6 m²

L² = 3.6 m²

L = 1.89 m say 2.0 m

FOOTING DIMENSION = 2m by 2m

Area = 4m²

Solve for SOIL FACTORED LOAD ( PU )

Case 1: PU = 1.4 P DL

= 1.4(342.09kN)

= 478.93kN

Case 2: PU = 1.2 P DL+1.6P¿

= 1.2(342.09kN)+1.6(66.18kN)

= 516.396kN
Case 2 governs; PU = 516.396kN

Computing for the Factored Upward Pressure

PU
qU =
A ftg

516.396 kN
=
4m²

= 129.009kN/m² = 0.129 MPa

Use 20mmØ bar with 70mm cc

Ø
d = t – cc - = 400mm – 70mm – 20/2mm = 320 mm
2

FAILURE MODES:

a. Based on two-way or punching shear

A shaded = (2mx2m) – (0.72m)(0.72m)

= 3.482m² = 3482000 mm²

vu = q u ( A shaded)

= 0.129MPa(3482000mm)

= 449.18kN

v c = ⅙ √ f ' c bd

= ⅙ √20.7 MPa(4)(400mm+320mm)

= 698.84kN
v c> vu therefore, the section is safe.

ɸ v c = 0.75(⅙) √ f ' cbd

= 0.75(698.84kN)

= 524.13kN

ɸ v c > vu , therefore it is safe for punching.

b. Based in Wide-Beam Shear

q u = 0.129MPa

d = 320mm

vup = vu A

= 0.129MPa(800mm-320mm)(2000mm)

= 123.84kN

v c = ⅙ √ f ' c bd

= ⅙ √20.7 MPa(2000mm)(320mm)

= 485.3kN

v c> vu . Therefore, the section is safe.

Solving for the reinforcement:

M u = q u(X)(L)(X/2)

= 0.129MPa(800)(2000)(800/2)
= 82.56kN.m

Mu
Rn =
ɸ bd

82.56 kN . m
= 2
0.90(2000)(320 )

= 0.447 MPa

0.85 f ' c 2 Rn
ρ=
fy √
(1− 1−
0.85 f ' c
)

0.85(20.7 MPa) 2(0.447 MPa)


=
276 MPa
(1− 1−

0.85(20.7 MPa)
)

= 0.00164

ρmin = 1.4/fy = 1.4/276MPa = 0.00507

Use ρmin = 0.00507

Computing for Area of steel:

A s= ρmin bd

= 0.00507(2000mm)(320mm)

= 3244.8mm²

Required number of steel bars:

Using 20mmØ bar ( Ab =314.16mm²)

As 3244.8 mm ²
N= = = 10.32 or say 11 pcs.
Ab 314.16 mm ²
Solve for spacing:

Ab
S= (2000mm)
As

314.16 mm ²
= (2000mm) = 193.54 mm
3244.8 mm ²

Adjust to 180mm spacing.

Use 11 – 20mm Ø bars spaced at 180 mm o.c.

Check for Development length

From Section 5.12.2 of the code, for 32mm bar and smaller and deformed wires,

0.02 A b fy
Ld =
√f ' c

0.02(314.16 mm2 )(276 MPa)


=
√20. 7 MPa

= 381.16 say 400mm

Ld = 0.06dbfy

= 0.06(20mm)(276MPa)

= 331 say 350 mm

Minimum area of dowel or extension bars by the code.

A = 0.005(400mmx400mm)
= 800mm²

Use 2m x 2m footing with an effective depth of 320 mm.

DESIGN OF WALL FOOTING

f’c = 20.7 MPa

fy = 276 MPa

Q a = 150 kPa (assumed)

W s = 17.5kN/m³ (Unit weight of Soil)

W c = 23.54kN/m³ (Unit weight of concrete)

H = 0.60 (assumed height)

W CHB = 16.98kPa (Masonry works with Plastered both sides)

Use 150mm x 200mm x 400mm CHB

Effective Soil Bearing Capacity (Q e )


d = h e – 75mm = 200mm – 75mm = 125 mm or 0.125m

Q e = Q a - W c he - W s h s - W c hb

= 150kPa – (23.54kN/m³)(0.2m) – (17.5kN/m³)(0.4m) – (16.98kN/m²)

(0.15)

= 135.751kN/m²

Consider 1m strip of wall

Required width (W)

W DL = 1m(23.54kN/m³)(0.2m) + 1m(16.98kN/m³)(3.3m)

= 60.742kN/m

60.742 kN /m
W= = 0.447m or 500mm
135.75 kN /m ²

Bearing Pressure for Strength Design, (q u)

1.4 W DL
qu = [ ] = 1.4 ¿ ¿
W

= 170.1 kN/m²

Design for Shear (V u)

At distance “d” from the face of the wall.

W wall thickness
s= –d-
2 2

0.5 m 0.15 m
= – 0.125m -
2 2
= 0.5m or 50mm

V u = q u(s)(1m strip) = 170.1kN/m²(0.05m)(1m)

= 8.5kN

6Vu 6 (8.5 kN )
d= = = 29.86mm
'
0.75 √ f c b 0.75 √ 20.7 MPa(500mm)

d < 125mm assumed d, ok!

W wall thickness 0.5 m 0.15 m


k= - = - = 0.175
2 2 2 2

M u = k(q u)(1m(k/2)

= 0.175(170.1kN/m²)(1m)(0.175/2) = 2.6 kN.m

Mu 2.6 x 106 N .mm


Rn = = = 0.36 MPa
Øbd 0.90(500 mm)(125 mm)²

Solve for ρ:

0.85 f ' c 2 Rn
ρ=
fy √
(1− 1−
0.85 f ' c
)

0.85(20.7 MPa) 2(0.449 MPa)


=
276 MPa
(1− 1−

0.85(20.7 MPa)
)

= 0.00148 < ρmin = 0.00507

Use ρmin .

Area of steel:

A s= ρmin bd
= 0.00507(1000mm)(150mm)

= 633.75mm²

Required number of steel bars:

Using 12mmØ bar ( Ab =113.097mm²)

As 633.75 mm ²
N= = = 5.6 or say 6 pcs.
Ab 113.097 mm ²

Solve for spacing:

Ab
S= (2000mm)
As

113.097mm ²
= (1000mm) = 178.46 mm
633.75 mm ²

Adjust to 150mm spacing.

FOR TEMPERATURE BARS,

Using 12mmØ bar ( Ab = 113.097mm²)

COMPUTING A S AND NUMBER OF BARS REQUIRED, N

A S = 0.002bh = 0.002(500mm)(200mm) = 200mm² (NSCP Sec. 407.13.2.1)

As 200 mm ²
N= = = 1.77 or say 2 pcs.
Ab 113.097 mm ²

Solve for spacing:

Ab
S= (1000mm)
As
113.097mm ²
= (1000mm) = 565.485 mm
200 mm ²

Adjust to 250mm spacing.

Development Length ( Ld )

According to Section 5.12.2 of the code, the basic development length shall be:

For 32mm bar and smaller deformed bars

0.02 A s fy
Ld =
√f ' c

0.02(200 mm2 )(276 MPa)


=
√ 20.7 MPa

= 137.75 say 150mm

Ld = 0.06dbfy

= 0.06(113.54mm)(276MPa)

= 140 say 150 mm

But not less than 0.06 Ø ¯¿ ¿fy

0.06 Ø ¯¿ ¿fy = 0.06(12mm)(276MPa) = 198.72 mm

500 mm 200 mm
Ld furnisfed = - – 70mm(cover)
2 2

= 80mm; ( Ld furnisfed is < Ld )

Adopt 198.72 say 200mm