TESA-REFLEX panel II
18.08.2011
TESA-REFLEX panel - SG HEXAGON METROLOGY 1
Concept
TESA-REFLEX panel is one of the TESA-REFLEX Concept key features
TESA-REFLEX panel - SG HEXAGON METROLOGY 2
Concept
• Simple in use
No complicated programming process
Simple to demonstrate by sales forces
• Intuitive
User friendly interface
Simple to understand quickly by customers
• Fast to learn
Required training course time minimised
Same interface between all particular software applications
• Accessible to everyone
No need to be a metrology specialist
No need to have one person dedicated by machine type
TESA-REFLEX panel - SG HEXAGON METROLOGY 3
Concept
TESA-REFLEX panel - SG HEXAGON METROLOGY 4
Concept
Except the following functionalities due to the the machine type specialities, those three
software version remain the same
Going from one version to another is really easy
TESA-REFLEX panel - SG HEXAGON METROLOGY 5
Concept
Reference version Automatic motion Probe calibration
• Program recalled in automatic or • Automatic probe recognition
manual modes • Only one probe calibration required
TESA-REFLEX panel - SG HEXAGON METROLOGY 6
Overview
Panel type Micro-Hite 3D / RC Micro-Hite 3D Recorder Multi-Gage
Software application TESA-REFLEX MH3D TESA-REFLEX Recorder TESA-REFLEX Multi-Gage
Screen Color Color Black/White
Resolution 0.0001 0.0001 0.0001
Peripherals management
USB printers
USB dongle
Connection with the machine Cable Cable Cable
Measurement Results
Data saving on USB dongle
Data through serial port
Data sending to USB printer
Measurement Program Management
Program saving on USB dongle
Additional Applications Compatibility
ReflexScan
PcDmis
StatExpress
DataDirect
Measurement Report Management
Report Header Management
Go/NOGo Report
Language
1x Customisable Language
TESA-REFLEX panel - SG HEXAGON METROLOGY 7
Simple Software
Only Simple Features
• Point • Circle • Cylinder • Sphere
• Line • Plane • Cone
Automatic Feature Recognition
• No need to be specialist
• Gain of time → No pevious programming required
Feature results
• All results automatically displayed
• Gain of time → No need to program for getting a particular result
User friendly
• Processes to follow
• Understandable and intuitive icons
• One day training is enough
TESA-REFLEX panel - SG HEXAGON METROLOGY 8
Color and user friendly icons
TESA-REFLEX Panel I Software Version TESA-REFLEX Panel II Software Version
TESA-REFLEX panel - SG HEXAGON METROLOGY 9
Measurement Data
Results management possibilities
Printer
USB dongle* + Computer**
+
*Creation of a text file in the stick
**Computer required for data processing
Cable + computer
+
Sol. 1: Hyperterminal → Text file creation
Sol. 2: Datadirect → Data sent autom. in Excel
Sol. 3: StatExpress → Automatic reports and stats
Panel***
***At each measurement steps, results are
displayed
***A Go/NoGo report can be displayed for each
measurement run
TESA-REFLEX panel - SG HEXAGON METROLOGY 10
Measurement Data
Several formats can be used
Datapage Space betwen values
• Prog. Name
• Feature
• Channel
• MV, Nom, UT, LT
Gagetalker Coma betwen values
• Prog. Name
• Feature n°
• Channel
• Feature
• MV, Nom, UT, LT, Dev
Mitutoyo (or Mux10) Measurement values only
• Feature n°
• Channel
• Measured value
Print Measurement values only
• Feature title
• One line/characteristic
• MV, Nom, UT, LT, Dev
TESA-REFLEX panel - SG HEXAGON METROLOGY 11
Measurement Data
Possibility 1
Printer Automatic report printed
Possibility 2
USB stick
Possibility 3
*.txt manual importation in
Excel
Hyperterminal
Excel report template
Possibility 4 filled
Data format Data automatically
selection imported in Excel
Datadirect
• Mitutoyo = Mux10
• Datapage Possibility 5
• Gagetalker
• Print
StatExpress Data automatically Several reports
collected in StatExp. automatically created
TESA-REFLEX panel - SG HEXAGON METROLOGY 12
Measurement Data
Possibilty 1: the printer
file created with Print format
Data sent to Printer
Company logo
• Company name
• Operator name
• Time and date
•…
Measurement part
TESA-REFLEX panel - SG HEXAGON METROLOGY 13
Data management
TESA-REFLEX can not manage protocols other than the PCL3 native ones.
TESA recommends the use of printer units from the following list, otherwise no formal
assurance with regards to compatibility can be provided.
TESA-REFLEX panel - SG HEXAGON METROLOGY 14
Measurement Data
Possibility 2: USB stick
1 2 3
1. Data are automatically sent to the USB stick where a *.txt file
is created
4
2. The *.txt file is transferred manually to a computer
3. The *.txt file is imported manually in the ‘data’ sheet of an
Excel file
4. The report template placed in the ‘report’ sheet of the Excel
file is filled automatically by the imported values.
5. The user can see at first sight if the part is good or not.
TESA-REFLEX panel - SG HEXAGON METROLOGY 15
Measurement Data
Possibilty 3: Hyperterminal
1 2 3
1. Data are automatically sent to the computer (through the serial port)
2. A *.txt file is automatically created 4
3. The *.txt file is imported manually in the ‘data’ sheet of an
Excel file
4. The report template placed in the ‘report’ sheet of the Excel
file is filled automatically by the imported values.
5. The user can see at first sight if the part is good or not.
TESA-REFLEX panel - SG HEXAGON METROLOGY 16
Measurement Data
Possibilty 2: Datadirect
1 2 3
1. Data are automatically sent to the computer (through the serial port)
2. Datadirect gets the data and sends them automatically in the
‘data’ sheet of an Excel file
3. The report template placed in the ‘report’ sheet of the Excel
file is filled automatically by the received values.
4. The user can see in real time if the part is good or not.
TESA-REFLEX panel - SG HEXAGON METROLOGY 17
Measurement Data
Possibilty 2: StatExpress
1 2 3
1. Data are automatically sent to the computer
(through the serial port)
2. Statexpress collects the data
3. Different reports can be generated automatically
concerning the measured characteristics, the
user can have in real time statistics about his
previous measurements.
TESA-REFLEX panel - SG HEXAGON METROLOGY 18
Data management
Additionnal applications
ReflexScan DataDirect StatExpress PcDmis
• Reverse engineering • Gets the data from panel • Gets data from the panel • CAD file importation
• Sending cloud of points • Forward them to a MS • Calculates in real time • CAD comparison
to computer application the statistics
• Format converting • Several fomats of data • Automatically creates Available through Hexagon
management reports channel only
• Files readable by famous
applications
TESA-REFLEX panel - SG HEXAGON METROLOGY 19
Data management
Go/NoGo Report
• When recalling a program saved or not
• Measurement overview automatically
displayed on the screen
• Global figures results available quickly
- Number of measures in the report
- Number of measures out of tolerance
- Purcentage of out of tolerance values
• Possibility to print all displayed values at the
same time
TESA-REFLEX panel - SG HEXAGON METROLOGY 20
Languages management
Custom Language
Option that gives to
a customer, the
possibility to
upgrade his panel
with a customized
language
TESA-REFLEX panel - SG HEXAGON METROLOGY 21
Panel Comparison
What is new with the TESA-REFLEX panel II?
Panel Type TESA-REFLEX I TESA-REFLEX II
Color screen
Screen size 89 x 118 mm 116 x 154 mm
Resolution 0.001 0.0001
Printers type compatibility Matrix USB
USB dongle
Data saving on USB dongle
Data through serial port
Data sending to printer
Measurement Programs saving On Pcmcia cards On USB dongle
Measurement Programs sharing/backup
ReflexScan / PcDmis / DataDirect / StatEx.
Report Header Management (picture)
Go/NOGo Report
Customisable Language
Software upgrade process With Pcmcia card upgrade at TESA With USB dongle at customer place
TESA-REFLEX panel - SG HEXAGON METROLOGY 22
Retrofit
Is the TESA-REFLEX panel II usable with previous machine versions?
Derby MS343 Micro-Hite 3D
Yes
Older machine types can be retrofitted with the new TESA-REFLEX panel II
Retrofitting this machine with a new panel implies
Machine type Panel version
the use of
Prior to Micro-Hite 3D DERBY panel An upgrade kit
Prior to Micro-Hite 3D TESA-REFLEX panel I A modified TESA-REFLEX panel II
Micro-Hite 3D TESA-REFLEX panel I A standard TESA-REFLEX panel II
TESA-REFLEX panel - SG HEXAGON METROLOGY 23
References
MH3D Derby,
MH3D Recorder Multi-Gage MS343, 454
MH3D RC Gage2000
Standard version panels
03960281
03960303
03862000
03960284*
Exchange version panels
03960281E
03960303E
03862000E
03960284E*
Second hand version panels
03960281R
03960303R
03862000R
03960284R*
Retrofit kits including modified panel
03960313
03960312
* 03960281 modified for old machines = 03960284
* Only for old machines already retrofitted with a TESA-REFLEX panel I, can not be used on Micro-Hite 3D
TESA-REFLEX panel - SG HEXAGON METROLOGY 24