Multi-Gas Detection

The Dräger X-am® 2500 was especially developed for use as personal
protection. The 1 to 4 gas detector reliably detects combustible gases and
vapours, as well as O2, CO, NO2, SO2 and H2S. Reliable and fully mature
measuring technology, durable sensors and easy handling guarantee a
high degree of safety with extremely low operating costs.

Safe gas entry Crocodile clip


Gas entry from two sides. Secure attachment.

Visual alarm
Alarm visible across 360°.

Dräger sensors
Quick, precise, long service life.

Robust design Large display


Water and dust resistant in acc. All values at a glance.
with IP 67.
D-59024-2012
02 | Dräger X-am® 2500

Benefits

Durable electrochemical sensors

Fully developed, high performance Dräger sensors in an extra small format for CO, H2S, O2, SO2 and NO2 gases
enable safe use in industry, mining and in refineries. The impressive hydrogen sulphide sensor has a high
resolution, so it can reliably measure even very low workplace limits. The non-consumptive and lead-free sensor
for oxygen is characterized by an especially long service life of more than 5 years. Our CO and H2S sensors
also have this long service life expectation, so they contribute to especially low operating costs.

Poison resistant ex sensor

The innovative, catalytic Ex sensor is im- pressive due to its high resistance to silicone and hydrogen sulphide.
Together with the high degree of drift stability, this resistance enables an extraordinarily long service life of
more than 4 years. Its sensitivity with regard to flammable gases and vapours is tested in accordance with the
technical approval for measuring IEC/EN 60079-29-1 from methane to nonane. This approval also demonstrates
the suitability of this instrument for primary explosion protection, e.g. for use in refineries and in the chemical
industry.

Maximum safety

The Dräger X-am 2500 has Ex approval for zone 0, so it is clearly designed for very high user safety in areas
subject to explosion hazard. The functional design ensures that gas can enter from above and from the side –
even if the instrument is inside a pocket or if the front gas entry is accidentally covered.

Maintenance: fast, easy, inexpensive

From functional test to complete documentation, users have access to practical solutions that provide safety for
implementation at any time. The Dräger Bump Test Station, which does not require a local power source, and
the automatic Dräger X-dock testing and calibration station for comprehensive equipment management are ideal
system additions that save time and effort. Together with the Dräger X-dock, the high quality Dräger sensors
enable quick bump tests of 8 to 15 seconds1 with very low gas consumption. This significantly reduces your
equipment operating costs.

1) With standard sensors: CH4, O2, CO, H2S

Diffusion or pump

For clearance measurements for tanks and shafts or when searching for leaks, an optional external pump with
a hose up to 30 m long is the optimum solution. The pump starts automatically when the measuring instrument
is inserted in the external pump. The switch from diffusion to pump operation can be handled quickly and easily
without tools or screws.
Dräger X-am® 2500 | 03

Benefits

Ergonomic and robust

Thanks to its low weight and ergonomic design, the Dräger X-am 2500 offers a high degree of wearing comfort.
The practical 2008two button control panel and easy menu navigation allow the instrument to be used intuitively,
despite its comprehensive functionality. The integrated protective rubber coating and sensors that are not
sensitive to shock provide additional safety in case of impacts or vibrations. More-over, the Dräger X-am 2500 is
not sensitive to electromagnetic radiation, e.g. from wireless devices. The Dräger X-am 2500 is water and dust
resistant in accordance with protection class IP67, so it remains fully functional even if it falls into the water.

Reliable power supply

The Dräger X-am 2500 can operate with either alkaline batteries or with rechargeable NiMH batteries. This
enables a reliable power supply for more than 12 hours, and with the high capacity battery pack more than 13
hours. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle.
Operating time without Ex sensor is typically more than 250 hours.

System components

Dräger X-dock® 5300/6300/6600

The Dräger X-dock® series provides you with full control of your
portable Dräger gas detection instruments. Automatic bump tests
and calibrations with reduced test gas consumption and short testing
times save time and money. Comprehensive documentation and
evaluations provide you with a clear overview.
D-47907-2012
04 | Dräger X-am® 2500

System components

Dräger Bump Test Station

Easy to use, stand-alone and portable. With the Bump Test Station,
functionality tests of gas detection and warning devices can be carried
out easily and quickly.
ST-740-2006

Accessories

Dräger X-am 125, external pump

External pump for hose length of up to 30 meters (98 feet). Makes it


possible to use the detector for pre-entry measurements into confined
spaces such as tanks, shafts, etc. The pump starts automatically when
the detector is inserted. The change between diffusion and pump
operation is quickly and easily possible without any need for additional
tools or steps.
ST-9477-2007

Power pack & Charging set

Consisting of: NiMH power supply, charging module, single charger


D-12284-2009
Dräger X-am® 2500 | 05

Related Products

Dräger X-am® 5000

The Dräger X-am® 5000 belongs to a generation of gas detectors,


developed especially for personal monitoring applications. This 1- to
5-gas detector reliably measures combustible gases and vapors as
well as O2 and harmful concentrations of toxic gases, organic vapors,
Odorant and Amine.
ST-9466-2007

Dräger X-am® 5600

Featuring an ergonomic design and innovative infrared sensor


technology, the Dräger X-am 5600 is the smallest gas detection
instrument for the measurement of up to 6 gases. Ideal for personal
monitoring applications, this robust and water-tight detector provides
accurate, reliable measurements of explosive, combustible and toxic
gases and vapors as well as oxygen.
D-27784-2009

Dräger X-am® 7000

Dräger X-am® 7000 is the solution for the simultaneous and


continuous measurement of up to five gases. It is the ideal companion
in a variety of applications where the reliable detection of oxygen, toxic
and combustible gases and vapors are necessary.
ST-67-2006
06 | Dräger X-am® 2500

Technical Data

Dimensions (W × H × D) 48 × 130 × 44 mm
Weight 220 – 250 g
Ambient conditions Temperature -20 to +50 °C
Pressure 700 to 1,300 mbar
Relative humidity 10 to 95 % r.h.
Protection class IP67
Alarms Visual 360°
Audible Multi-tone > 90 dB at 30 cm
Vibration
Operating times > 12 h with alkaline and NiMH,
> 13 h with NiMH HC,
> 250 h w/o Ex sensor with alkaline batteries
Charging time <4h
Datalogger Retrievable using an infrared interface > 1,000 h with 4 gases at a
recording interval of 1 value per minute
Approvals ATEX I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb,
II 2G Ex d ia IIC T4/T3 Gb
Performance approval to:
EN 50104 (2002) + A1(2004) O2
EN 45544 CO & H2S
EN 60079-29-1:2007 Methane to nonane
EN 50271:2010 Software and documentation
CSA Class I Div. 1 Group A, B, C, D T.-Code T4/T3
(Canada & USA) A/Ex ia IIC T3 /Ga
A/Ex d ia IIC T4/ T3 /Gb
IECEx Ex ia I Ma
Ex ia IIC T3 Ga
Ex d ia I Mb
Ex d ia IIC T4/ T3 Gb
CE mark Electromagnetic Compatibility (Directive 2004/108/EC);
ATEX (Directive 94/9/EC)
MED Marine Equipment Directive (Directive 96/98/EC)

Ordering Information

Dräger X-am® 2500 Order No.

Dräger X-am® 2500 - Available in various versions. Cannot be


modified later with other sensors. Includes calibration certificate.
No power supply included.
Dräger X-am® 2500 EX1) 83 23 910
Dräger X-am® 2500 Ex, O2 1) 83 23 912
Dräger X-am® 2500 Ex, O2, H2S-LC1) 83 23 914
Dräger X-am® 2500 Ex, O2, CO1) 83 23 916
Dräger X-am® 2500 Ex, O2, H2S-LC, CO1) 83 23 918

Dräger X-am® 2500 Flex 1) 83 23 900


Choice of four sensors (1 slot for CatEx and 3 slots for XXS
sensors). Can be modified later with other sensors.
Includes calibration certificate. No power supply included.
Dräger X-am® 2500 | 07

Ordering Information

DrägerSensors Measuring range Resolution Response time(t90) Expected service


life
CatEx 125 PR1) 0 – 100 % LEL 1 % LEL 10 sec. > 4 years 68 12 950
0 – 5 Vol.-% CH4
CatEx 125 Mining 0 – 100 % LEL 1 % LEL 10 sec. > 3 years 68 13 080
PR 0 – 100 Vol.-% CH4
DrägerSensor XXS 0 – 25 Vol.-% 0,1 Vol.-% 10 sec. > 5 years 68 10 881
O2 1)
DrägerSensor CO1) 0 – 2,000 ppm 2 ppm 15 sec. > 5 years 68 10 882
DrägerSensor XXS 0 – 100 ppm 0,1 ppm 15 sec. > 5 years 68 11 525
H2S LC1)
DrägerSensor NO2 0 – 50 ppm 0,1 ppm 15 sec. > 3 years 68 10 884
DrägerSensor SO2 0 – 100 ppm 0,1 ppm 15 sec. > 3 years 68 10 885
1)Dräger provides a 3 year guarantee on the Dräger X-am® 2500 and these sensors.
The legal rights arising from defects remain unaffected.

Power supply units


NiMH power pack T4 with charging module and PSU (complete 83 18 785
set)
NiMH power pack T4 83 18 704
NiMH HC power pack T4 with charging module and PSU 83 22 785
(complete set)
NiMH HC power pack T4 83 22 244
Alkaline power pack (w/o batteries) 83 22 237
Alkaline batteries T4 (2 pcs.) for power pack 83 22 237 83 22 240

Charging accessories
Charging module 83 18 639
Charging kit consisting of a charging module and a single charger 83 20 333
(worldwide)
Power pack with power cord (worldwide) for multiple charging 83 15 805
modules (max. 20)
Single charger (worldwide) for multiple charging modules (max. 83 16 994
5)
Single charger (worldwide) for multiple charging modules (max. 83 15 635
2)
Vehicle charging cable 12 V / 24 V for charging module 45 30 057
Vehicle mounting kit for a Dräger X-am® 1/2/5x00 charging 83 18 779
module

Pump accessories
Dräger pump X-am® 125, external pump 83 19 400
Manual pump adapter 83 19 195
Confined Space Entry Kit with external pump and 3 m Viton® hose 83 19 399
Empty case with room for X-am® 1/2/5x00, charging accessories, 83 20 467
probe, gas cylinder, pump, 3 m hose, etc.
08 | Dräger X-am® 2500

90 94 028 | 15-02-3 | Communications & Sales Marketing | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2015 Drägerwerk AG & Co. KGaA
Ordering Information

Calibration accessories
Calibration cradle for Dräger X-am® 1/2/5x00 83 18 752
Dräger X-dock® 5300 for Dräger X-am® 1/2/5x00 83 21 880
Other versions of Dräger X-dock® by request
Dräger Bump Test Station for Dräger X-am® 1/2/5x00 (w/o gas 83 19 131
cylinder)
Dräger Bump Test Station for Dräger X-am® 1/2/5x00, incl. gas 83 19 130
cylinder 58L (gas and concentration can be selected)
Nonane tester for Dräger X-am® 1/2/5x00 83 20 080

Communication Accessories
Dräger GasVision 83 14 034
Dräger CC-Vision Freeware
USB DIRA with USB cable, IR communication adapter to USB 83 17 409
Viton® is a trademark of DuPont.

CORPORATE HEADQUARTERS REGION EUROPE CENTRAL REGION MIDDLE EAST, AFRICA REGION CENTRAL
Drägerwerk AG & Co. KGaA AND EUROPE NORTH Dräger Safety AG & Co. KGaA AND SOUTH AMERICA
Moislinger Allee 53–55 Dräger Safety AG & Co. KGaA Branch Office Dräger Panama S. de R.L.
23558 Lübeck, Germany Revalstraße 1 P.O. Box 505108 Complejo Business Park,
www.draeger.com 23560 Lübeck, Germany Dubai, United Arab Emirates V tower, 10th floor
Tel +49 451 882 0 Tel +971 4 4294 600 Panama City
Fax +49 451 882 2080 Fax +971 4 4294 699 Tel +507 377 9100
[email protected] [email protected] Fax +507 377 9130
Manufacturer: [email protected]
Dräger Safety AG & Co. KGaA REGION EUROPE SOUTH REGION ASIA PACIFIC
Revalstraße 1 Dräger Safety France SAS Draeger Safety Asia Pte Ltd
23560 Lübeck, Germany 25, rue Georges Besse 25 International Business Park
92182 Antony Cedex #04-20/21 German Centre
Tel +33 1 46 11 56 00 Singapore 609916
Fax +33 1 40 96 97 20 Tel +65 6308 9400
[email protected] Fax +65 6308 9401
[email protected]

Locate your Regional


Sales Representative at:
www.draeger.com/contact

You might also like