Dehumdifier 1
Dehumdifier 1
Dehumdifier 1
INDUSTRIAL DEHUMIDIFIER
FLi - SERIES
FLi WITH HIGH PERFORMANCE, METAL SILICATE FLUTED
DESICCANT SYNTHESISED ROTOR
FLi 1500 1500 300 1.1 500 250 0.75 18 415 / 3 / 50 225
FLi 2000 2000 300 1.5 667 250 1.1 24 415 / 3 / 50 250
Reactivation Air
Inlet
Size- P x Q
FLi 1000 600 700 1368 1120 1806 608 428 121 40 150 982 624 620 154 124 350 377 98 130
FLi 1500 600 700 1368 1156 1790 651 286 121 40 150 982 624 620 340 200 350 377 111 154
FLi 2000 600 700 1368 1156 1790 651 286 121 40 150 982 624 620 340 200 350 377 111 154
Performance charts are for nominal process airflow within the operating range each FL i Series and
assumes XPI = XRI. Please consult bry-air for other specific condition.
35°C
30°C
14 50
25°C Example :-
20°C Conditions:
12 15°C
40
process inlet w PI = 12g/kg,
10°C
Process inlet T PI. = 200c
10 30
35°C
30°C Chart data :-
25°C
2 35°C
30°C 20
25°C process outlet w PO = 5g/kg,
1.5
20°C
20°C
Process outlet T PO. = 46.50c
15°C 6
1
10°C
0.5 4
15°C
0
2 4 2
10°C
0
0 2 4 6 8 10 12 14 16 18
Example :-
1000
1500
2000
2500
3000
3500
10948.0 325
11000.0 Airflow (m3/h)
11500.0
12000.0
FEATURE OVERVIEW
Items Standard Optional
Construction : Cold drawn steel SS frame with GI internal screen & cold drawon st
Stainless steel
INDUSTRIAL DEHUMIDIFIER
FLi - SERIES
FLi WITH HIGH PERFORMANCE, METAL SILICATE FLUTED
DESICCANT SYNTHESISED ROTOR
FEATURE HIGHLIGHTS
High efficiency and reliability
* Certifiied as per standard EN ISO12100-1:2003, Easy to operate
EN ISO12100-2:2003,EN60204-1:2006+A1 2009 * Suitable for continuous operation
* Meeting essential requirements of European directives * Auto / manual selector switch.
Low Voltage directive 2006/95/EC * Volume control dampers for both (P&R) air flow
machine directive 2006/42/EC, EMC : 2004/108/EC Easy to install
* A totally self contained unit. * Versatile, easy to package and handle
* Robust stainless steel frame with double skin construction, * Small footprints; low volume/weight per CMH
internal GI sheet. Easy to maintenance
* CNC fabricated with industrial grade coating. * Rotor is water washable
* High moisture removal. *
* EU-3 grade leak tight filters for Air intakes. Options
* Multiple choice of reactivation heat source:- * Humidity control by humidistat on/off
electrical, steam, thermic fluid, direct/indirect fired gas * Stainless steel construction
* In-bolt process by-pass for custom designing of process * Bry-Smart Controller
air flow or process tempreture control
* Easy addition of pre/after cooler, higher grade filter
* Rotor incorporates robust internal structure with
perimeter flange for industrial quality and durability.
* Rotor perimeter flange extend media and seal life
* Rotor is non-flammable with organic < 2%.
* Edge hard face coating on rotor edge ensures long life and
good sealing for media and seals.
* Process and reactivation air flow sectors are insulated
* Unique PTFE bonded bulb seal design;minimized air leakage
INDUSTRIAL DEHUMIDIFIER - FLi
PROCESS PROCESS PROCESS REACT REACT REACT REACT POWER* APPROX.
MODEL AIR FLOW ESP MOTOR AIR FLOW ESP MOTOR HEATER REQD. WEIGHT
CMH (Pa.) KW CMH (Pa.) KW KW (Kg)
FLi 2500 2500 300 1.5 833 250 0.75 26 415 /3/ 50 500
FLi 3000 3000 300 1.5 1000 250 0.75 33 415 / 3 / 50 500
FLi 4200 4200 300 2.2 1400 250 1.1 46 415 / 3 / 50 550
FLi 5000 5000 300 3.7 1667 250 1.1 53 415 / 3 / 50 550
FLi 6200 6200 300 2.2 2067 250 1.5 64 415 / 3 / 50 950
FLi 7300 7300 300 3.7 2433 250 1.5 76 415 / 3 / 50 950
FLi 8000 8000 300 3.7 2667 250 1.5 85 415 / 3 / 50 1025
FLi 9000 9000 300 3.7 3000 250 2.2 96 415 / 3 / 50 1050
FLi 10500 10500 300 3.7 3500 250 2.2 114 415 / 3 / 50 1050
* Note:- Other voltage available are 200/220/240/415/440/460 VAC, 3Ph, 50/60 Hz
4
R
25 40
J G N
90
40
E
850
A
D
FLi 2500 1050 1220 1770 1594 2600 876 249 210 103 150 1324 939 925 244 340 476 515 150 160
FLi 3000 1050 1220 1770 1594 2600 876 249 210 103 150 1324 939 925 244 340 476 515 150 160
FLi 4200 1050 1220 1770 1618 2600 936 249 210 103 150 1266 939 925 270 375 476 515 200 340
FLi 5000 1050 1220 1770 1618 2600 936 249 210 103 150 1266 939 925 270 375 476 515 200 340
FLi 6200 1050 1400 1950 1740 2600 1191 249 251 138 150 1448 1038 1030 390 552 476 617 200 340
FLi 7300 1050 1400 1950 1740 2600 1191 249 251 138 150 1448 1038 1030 390 552 476 617 200 340
FLi 8000 1050 1600 2150 1788 2730 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375
FLi 9000 1050 1600 2150 1788 2730 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375
FLi 10500 1050 1600 2150 1788 2730 1291 258 169 138 150 1481 1248 1235 438 614 631 619 268 375
Performance charts are for nominal process airflow within the operating range each FLi Series and
assumes XPI = XRI. Please consult bry-air for other specific condition.
16 60
35°C
30°C
14 25°C 50 Example :-
20°C Conditions:
15°C
12 40 process inlet w PI = 12g/kg,
10°C Process inlet T PI. = 200c
10 35°C 30
30°C Chart data :-
25°C
2 35°C
30°C 20
1.5
25°C process outlet w PO = 5g/kg,
20°C
20°C Process outlet T PO. = 46.50c
15°C 6
1
10°C
0.5 4
15°C
0
2 4 2
10°C
0 2 4 6 8 10 12 14 16 18
Example :-
20
15
FLi-2500
FLC-2500 FLi-3000
FLC-3000 FLi-4200
FLC-4200 FLi-5000
FLC-5000 FLi-6200
FLC-6200
300
340
300
320
305
STATIC PRESSURE (Pa)
300
300
305
280
7000 305
260
300
240
300
220
200 300
0 1000 1500 2000 2500 3000 3500 4000 5000 5500 6000 6500 7000 7500 8000 8500 9000 9500 10000 10500 11000 11500
FEATURE OVERVIEW
Items Standard Optional
Construction : Cold drawn steel SS frame with GI internal screen & cold drawon steel
Stainless steel