0% found this document useful (0 votes)
141 views15 pages

Earth Quake Load Calculation

This document provides design specifications for a seven storey building, including load assumptions, soil properties, material strengths, and calculations for structural components. Live loads are specified as 2 kN/m^2 for floors and 1.5 kN/m^2 for the terrace. Foundation depth is 3m below ground. Design is for M25 grade concrete and Fe 415 reinforcement. Gravity and lateral load calculations are shown for slab, beam, column and foundation design according to Indian codes. Earthquake loads are also calculated.

Uploaded by

Bala Subramanian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views15 pages

Earth Quake Load Calculation

This document provides design specifications for a seven storey building, including load assumptions, soil properties, material strengths, and calculations for structural components. Live loads are specified as 2 kN/m^2 for floors and 1.5 kN/m^2 for the terrace. Foundation depth is 3m below ground. Design is for M25 grade concrete and Fe 415 reinforcement. Gravity and lateral load calculations are shown for slab, beam, column and foundation design according to Indian codes. Earthquake loads are also calculated.

Uploaded by

Bala Subramanian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 15

DESIGN OF SEVEN STOREY BUILDING

Live Load : 2 kN/m²

Live Load : 1.5 kN/m² ( Terrace )

Floor Finish : 1 kN/m²

Water Proofing : 2 kN/m²

: As per IS:875(Part-2) - Not Design for Wind Load, Since Earthquake


Wind Load
Load is exceed the Wind Loads

Earthquake Load : As per IS:1893(Part-1)-2002

Depth of foundation : 3 m
Below Ground Level

Type of soil :

Allowable Bearing
: 28.5 kN/m²
Pressure

Average Thickness of
:
Footing

Storey Height : 3m ( For Each Floors)

Floors : Basement + Seven Floors

Plinth Level : 6'6"


Walls : 230mm Thick Wall
Material Properties

Concrete : All component unless specified in Design M25 grade all

Ec = 5000 √fck N/mm²

= 25000 N/mm²

Steel :
HYSD Reinforcement of grade Fe 415 conforming to IS-1786 used
throughout

GRAVITY LOAD CALCULATION

Brick Wall
0.23 x 19 ( Wall ) x 2 0.012 x 20 ( plaster ) = 4.9 kN/m²
(230mm thick) =

Slab (5" thick) 0.127 x 25.00 = 3.81 kN/m²


=

FACTOR LOAD CALCULATION

Factor of Safety = 1.5


STRUCTURAL DESIGN
COLUMN DESIGN CALCULATION
WAFFLE SLAB DESIGN CALCULATION
PLINTH BEAM DESIGN CALCULATION
RAFT SLAB & BEAM DESIGN CALCULATION
STAIR DESIGN CALCULATION
3.175
Earth Quake Load:

20.1 x 12.3 m
Floor Area = 247.23 sq. ft = 22.96842 sq. m

Terrace Load = 7.68 x 22.968 = 176.39745 Kn

Typical Load = 7.18 x 22.968 = 164.91325 Kn

Total Load = 1330.79 Kn

wxhxh (wxhxh / Lateral Force for EL


Storey Level W h hxh
/1000 Total(wxhxh)) X Y

7 164.91 21 441 72.73 0.35 62.88 62.88


6 164.91 18 324 53.43 0.257142857143 46.20 46.20
5 164.91 15 225 37.11 0.178571428571 32.08 32.08
4 164.91 12 144 23.75 0.114285714286 20.53 20.53
3 164.91 9 81 13.36 0.064285714286 11.55 11.55
2 164.91 6 36 5.94 0.028571428571 5.13 5.13
1 164.91 3 9 1.48 0.007142857143 1.28 1.28
Total 207.79
X-Direction
EL
T = 0.09 h / (d)½
h = 21 m
d = 20.1 m
T = 0.421564 sec

Building Located at Type II


Sa/g = 2.5
Z = 0.36
I = 1.5
R =5
Ah = (Z I/2R) X (sa/g)
Ah = 0.135
Base Shear = VB = Ah x w
= 179.66

Y-Direction
EL
T = 0.09 h / (d)½
h = 21 m
d = 12.3 m
T = 0.538901 sec
Building Located at Type II
Sa/g = 2.5
Z = Z = 0.36
I = I = 1.5
R = R = 5
Ah = (Z I/2R) X (sa/g)
Ah = 0.135
Base Shear = VB = Ah x w
= 179.66 Kn
Slab Load APPARTMENT
Component Terrace Typical
DL LL DL LL
Self Wt 3.18 0 3.18 0
Water Proof 2 0 0 0
Floor Finish 1 0 1 0

Live Load 0 1.5 0 3

Total 6.18 1.5 4.18 3