You are on page 1/ 1

Project: Two Storey Steel Building f'c 21 Mpa

Location: Cabadbaran City fy 230 Mpa


Date: February 11, 2020 Aggr. Size 20 mm
Structure: Exposure Interior
Index: Design by: Beam Width 300 mm
17, 18,Designation:
19, 46, 47, 48, 67, 68, 69, 70, 71, 72, 73,GR
74,Silot
92, 93, 94, 95
Beam Depth 500 mm

300 mm 300 mm 20 300 mm


4 - 20 mmØ 3 - 20 mmØ 4 - 20 mmØ
2 - 20 mmØ 2 - 20 mmØ

500 mm

4 - 20 mmØ 4 - 20 mmØ 4 - 20 mmØ

End 1 Midspan End 2

Node : 3, Node : 8,
8, 19, 9, 19, 34, 20,
20, 35, 3, 35, 49, 9,
9, 8, 20, 22, 20, 38,
19, 35, 34, 35, 52, 49,
49, 22, 38, Use 10 mm stirrups Length = 5.57 m Use 10 mm stirrups
64, 38, 53,
@300mm @300mm
END 1 MIDSPAN END 2
fMu (kN-m) Capacity fMu (kN-m) Capacity fMu (kN-m) Capacity
Top bars : -136 -150 Safe -21 -82 Safe -134 -150 Safe
bottom bars : 63 108 Safe 58 108 Safe 64 108 Safe

programmed by: R. F. Torregosa Ph.D, M.Eng., BSCE