CHF101/CHW-S12

Flux/Wire Combination for Submerged Arc Welding


AWS A5.17M F48A4-EM12K

ISO 14171-A-S 38 4 FB S2Si

ISO 14171-B-S 49A 4 FB SU21

BS EN 756-S 38 4 FB S2Si

Type of Flux: Agglomerated (sintered)


Type of Current: DCEP or AC

Features & Applications


CHF101 is a fluoride-basic type sintered flux and its basicity is about 1.8. The welding
performance of this combination is good arc stability and good slag detachability and the
weld metal has fine appearance and good performance of low temperature impact
toughness. It is suitable to weld structures made by mild steels or equivalent tensile
strength low alloy steels, such as boilers, pressure vessels, LPG cylinders and so on.

Chemical Composition (%)


C Mn Si S P Cr Ni
CHW-S12 Standard 0.05-0.15 0.80-1.25 0.10-0.35 ≤0.030 ≤0.030 — —
(EM12K) Typical 0.08 1.06 0.22 0.014 0.016 0.025 0.026
Deposited Metal Typical 0.056 1.30 0.30 0.011 0.020 0.02 0.01

Mechanical Properties of Deposited Metal (AW)


Tensile Strength Yield Strength Elongation Impact Value (J)
Rm (MPa) ReL (MPa) A4 (%) -40℃
Standard 480-660 ≥400 ≥22 ≥27
Typical 510 420 30 110
X-ray radiographic inspection: Grade Ⅰ

Quality Guarantee of Flux


Moisture Solid Impurities S P Mesh
≤0.10% ≤0.30% ≤0.060% ≤0.080% 10-60

Approvals
Institute LR ABS GL BV DNV NK
Grade 3YM 3YM 3YM A3YM ⅢYM KAW53M

Notice: 1) To avoid rust the wire must be kept in dry condition and keep the package in
good condition also before welding.
2) The flux should be re-baked at 300℃-350℃ for 1-2 hours before use.
3) The surfaces to be welded must be cleaned away impurities of oil
contamination, rust, moisture and so on.
4) The welding conditions mentioned above for reference only and it is better to
do a welding procedure qualification according to project before put it into
formal welding.