White Book C04 S02 Partitions GypWall CLASSIC
White Book C04 S02 Partitions GypWall CLASSIC
White Book C04 S02 Partitions GypWall CLASSIC
Partitions
This section contains a full range of lightweight partition and wall
systems for use in new and existing buildings. They cover all applications,
from simple space division to high performance walls
Partitions
C04
Introduction
Partitions
British Gypsum offers a full range of lightweight
partition and wall systems. Our systems are
non-loadbearing and constructed using modern,
drylining techniques. British Gypsum metal
framed partitions and walls can be used in all
types of new and existing buildings, including
private and social housing, apartments,
Partitions
healthcare, educational facilities, recreational
and industrial properties.
C04
They cover all applications, from simple space
division, through to high performance walls
designed to meet the most demanding fire
resistance, sound insulation, impact and height
requirements.
When specifying partitions, a number of performance characteristics are normally used to determine the required solution.
Depending on the project or construction type, these performance parameters could be set by minimum regulatory
standards, or a client or customer requirement for buildings that offer the highest standards of performance and comfort.
Our quick-reference partition system guide, below, allows you to simply select the performance categories of interest and
identify the British Gypsum partitions systems that best satisfy your project requirements.
Duty Maximum
Fire rating height1
Partition
Acoustic performance
performance thickness System Page
Partitions
Medium -
30 - 120 75 - 211 34 - 63 47 - 57 8100 GypWall classic C04.S02.P02
Severe
C04
Heavy -
30 - 90 102 - 208 49 - 63 48 - 55 5700 GypWall staggered C04.S06.P02
Severe
Non-loadbearing timber
30 - 120 88 - 196 34 - 52 - - - C04.S11.P02
stud (internal partitions)
Non-loadbearing timber
60 - 90 141 - 293 56 - 63 48 - 53 - - C04.S11.P05
stud (separating walls)
1
Based on studs at 600mm centres
Additional information
Try out The White Book System Selector, an online tool designed to help find the ideal solutions for your
project needs. Additional information such as BIM data (Revit), NBS clauses, CAD drawings and other
associated items can be downloaded. Visit british-gypsum.com
Introduction
Acoustic performance
Table 1 — Sound insulation performance for residential specification
On-site Laboratory2
Approved Document E (England and Wales) Minimum solution Recommended solution
DnT,w + Ctr dB
(Rw + Ctr ) dB (Rw + Ctr ) dB
On-site Laboratory2
Partitions
Technical Standards Section 5 (Scotland) Minimum solution Recommended solution
DnT,w + Ctr dB
Rw dB Rw dB
C04
or conversion (traditional buildings1)
1
Definition of traditional buildings - A building or part of a building of a type constructed before or around 1919:
a) using construction techniques that were commonly in use before 1919; and
b) with permeable components, in a way that promotes the dissipation of moisture from the building fabric.
2
Minimum solutions provide little or no margin of safety to allow for reduction in performance due to flanking transmission. Recommended solutions have
greater potential to satisfy the requirements of Building regulations.
Table 2 – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting deflection of L/240 at
200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
48 S 50 1 x 12.5mm 2500 2800 2900 3200 3100 3500
1 x 15mm 2800 3000 3100 3300 3300 3600
2 x 12.5mm 3400 3600 3600 3800 3800 4000
2 x 15mm 3700 3800 3900 4000 4000 4200
48 I 50 1 x 12.5mm 2900 - 3400 - 3700 -
1 x 15mm 3100 - 3500 - 3800 -
Partitions
In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.
Introduction
Table 2 (continued) – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting
deflection of L/240 at 200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to
EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
92 S 60 1 x 12.5mm 4700 5000 5200 5600 5600 6100
1 x 15mm 4900 5300 5400 5800 5800 6300
2 x 12.5mm 5800 6000 6100 6500 6500 6900
2 x 15mm 6000 6200 6300 6700 6600 7000
92 AS 50 1 x 12.5mm 4700 5100 5200 5700 5700 6200
Partitions
1 x 15mm 4900 5300 5400 5700 5800 6400
2 x 12.5mm 5800 6100 6200 6500 6500 6900
2 x 15mm 6000 6300 6400 6700 6700 7000
92 S 10 1 x 12.5mm 5300 5800 6000 6600 6500 7200
1 x 15mm 5500 6000 6100 6700 6600 7300
C04
2 x 12.5mm 6200 6600 6700 7200 7200 7700
2 x 15mm 6400 6800 6900 7400 7300 7800
92 I 90 1 x 12.5mm 6000 - 6800 - 7400 -
1 x 15mm 6200 - 6900 - 7500 -
2 x 12.5mm 6800 - 7400 - 7900 -
2 x 15mm 6900 - 7500 - 8000 -
146 S 50 1 x 12.5mm 6200 6800 6900 7600 7500 8300
1 x 15mm 6500 7000 7200 7800 7700 8400
2 x 12.5mm 7600 8000 8100 8600 8500 9100
2 x 15mm 7900 8200 8300 8800 8700 9300
146 AS 50 1 x 12.5mm 6600 7100 7300 8000 8000 8800
1 x 15mm 6800 7400 7600 8200 8200 8900
2 x 12.5mm 7800 8200 8400 8900 8900 9500
2 x 15mm 8100 8500 8600 9100 9100 9700
146 I 80 1 x 12.5mm 7900 - 8900 - 9700 -
1 x 15mm 8100 - 9000 - 9800 -
2 x 12.5mm 8800 - 9600 - 10400 -
2 x 15mm 9000 - 9800 - 10500 -
146 TI 90 1 x 12.5mm 8300 - 9400 - 10300 -
1 x 15mm 8400 - 9500 - 10400 -
2 x 12.5mm 9200 - 10100 - 10900 -
2 x 15mm 9400 - 10300 - 11100 -
In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.
To be read in conjunction with system specific details. Refer to relevant system sections
1 1a
1
3
5
5
Partitions
300mm
2
600mm
600mm
600mm
C04
2
300mm
6
7
2 2a
Centres
at 600mm
Centres
at
thereafter
600mm
thereafter
1479mm
1479mm
50mm
50mm
50mm
38mm
30mm
38mm
879mm
879mm
279mm
279mm
Service cut-outs - Gypframe ‘C’ and Gypframe ‘I’ Studs Service cut-outs - Gypframe AcouStuds
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
3 3a
Partitions
11
4
3 6
3
1
C04
2 7
6
4
10
Head and base Junction with masonry and stop end detail
To be read in conjunction with system specific details. Refer to relevant system sections
5 6
2 1
3
Partitions
7a 7b
2 2
1
1
4
3
3
‘T’ junction to optimise acoustic performance and reduce ‘T’ junction to optimise acoustic performance and reduce
flanking transmission flanking transmission
8 9
2 1
1
5
2
3
1 Gyproc plasterboard or Glasroc F specialist board 4 Gypframe GA5 Internal Fixing Angle
2 Gypframe 'C' Stud 5 Gypframe GA6 Splayed Angle
3 Isover insulation
Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
10 11
1
1
2
2
Partitions
Corner detail - single layer Corner detail - double layer
C04
12 13
16
mm
12 12
mm mm
2
3
1
1
4
14
Installing the screw into the side of the Gypframe Service Support Plate and the web of the Gypframe 'C' Stud will avoid creating excessive distortion to
the lining board.
To be read in conjunction with system specific details. Refer to relevant system sections
15
15mm 7 16 15mm 7
15mm 6 15mm 6
4 4
20mm 15mm 10
3
11
2
1 2
1
Partitions
Deflection head for 15mm downward movement Deflection head for 15mm downward movement
and 60 minutes fire resistance and up to 120 minutes fire resistance
Not suitable for 60 minutes single layer systems on 48mm studs to Not suitable for 48mm studs to BS EN 1364-1
C04
BS EN 1364-1
17 7 18
7
25mm 50mm
8 8
7
25mm 7 50mm
5 5
55mm
30mm
3
3
2
2
1
1
Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance and 60 minutes fire resistance
19 20 7
7
25mm 9
50mm
9
7
25mm 7
50mm
5 5
30mm
3 55mm
3
2 2
1 1
Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance and 60 minutes fire resistance
No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap (or stud nogging in construction detail 16). Continuous Gyproc FireStrip must be installed as shown to
maintain fire performance. Where there is a need for a deflection head in a 90 minute wall, the 120 minute solution can be used (refer to construction detail 16)
or alternatively, please contact the British Gypsum Technical Advice Centre for further guidance.
To minimise loss in acoustic performance refer to C02 S01 P10 Acoustic performance of head details.
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
21 2 22
5 7
2
9
5
8
15mm 6 15mm 6
15mm 15mm
3 3
15mm 10
15mm
Partitions
10
4
4
C04
1
1
Deflection head parallel to floor profile for 15mm downward Deflection head perpendicular to floor profile for 15mm downward
movement and up to 60 minutes fire resistance 1 movement and up to 60 minutes fire resistance
Not suitable for 60 minutes single layer systems on 48mm studs to Not suitable for 60 minutes single layer systems on 48mm studs to
BS EN 1364-1 BS EN 1364-1
23 24
12 12
13 13
1
1
4
4
11 11
14
No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap. Continuous Gyproc FireStrip must be installed as shown to maintain fire performance.
1
To minimise acoustic downgrade, install Isover insulation within the hollow rib void.
To be read in conjunction with system specific details. Refer to relevant system sections
25
Partitions
150mm
4
C04
1200mm 1200mm
Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Light and Medium Duty (up to 35kg door)
1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel 7 Timber sub-frame
4 Gypframe Floor & Ceiling Channel cut and bent to form door head
Advice should be sought from the door manufacturer prior to the construction of these details.
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
26
150mm
Partitions
4
C04
3
2
300mm
1200mm 1200mm
150mm
Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)
1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel to sleeve studs 7 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head
Advice should be sought from the door manufacturer prior to the construction of these details.
At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws. The
studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.
To be read in conjunction with system specific details. Refer to relevant system sections
27
8
7
Partitions
150mm
4
C04
2
300mm
150mm
Alternative door frame for fixed partition heads only (maximum 1200mm width) to satisfy
BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)
1 Gyproc plasterboard or Glasroc F specialist board 6 Gypframe 'C' Stud to maintain stud module
2 Gypframe 'C' Stud 7 Gypframe 'C' Studs fixed back to back with
British Gypsum Drywall Screws at 300mm centres staggered
3 Gypframe Floor & Ceiling Channel to sleeve studs
8 Plasterboard infill (same type as lining) cut to fit between studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head
9 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
5 Timber door frame and architrave
Advice should be sought from the door manufacturer prior to the construction of these details.
At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws.
The studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.
The principle of this alternative detail is only suitable for GypWall classic, GypWall robust and GypWall extreme for fixed head situations only.
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
28
3
1
Partitions
150mm
4
C04
5
150mm
Openings 1201 - 3300mm wide, for example double doors or large windows
1 Gypframe 'C' Stud 6 Centre stud required for margin up to 600mm between openings
2 Stud sleeved to full opening height with Gypframe Floor & Ceiling Channel 7 Partition between openings, minimum 600mm for Gypframe 'C' Studs
3 Gypframe studs (appropriate to system) (minimum 300mm for Gypframe 'I' Studs)
4 Gypframe Extra Deep Flange Floor & Ceiling Channel 8 Maximum distance 2400mm (if exceeds 2400mm contact British Gypsum
Technical Advice Centre)
5 Gypframe stud insert
To be read in conjunction with system specific details. Refer to relevant system sections
29 30
Elevation
4
X
Y
Partitions
2
C04
2
Section X - X
1
Fire tested construction in which the damper is supported
3 by the partition (isometric view)
4 31
150mm
6
Section Y - Y
Opening for service penetrations in fire-rated partitions Opening up to 600mm wide for services
1 Gyproc plasterboard or Glasroc F specialist board 5 Damper (by others). Weight of damper should not exceed 57kg.
2 Gypframe 'C' Stud Size of damper should not exceed 1400 x 1200mm
3 Gypframe Floor & Ceiling Channel 6 Gypframe Folded Edge Standard Floor & Ceiling Channel cut and bent
to form opening head and cill
4 Penetration seal if required (refer to damper manufacturer for details)
Introduction
To be read in conjunction with system specific details. Refer to relevant system sections
32
Partitions
5
C04
2
33 34
2 6
7 7
Horizontal board joint - double layer Horizontal board joint - single layer
1 Inner layer of Gyproc plasterboard or Glasroc F specialist board 5 British Gypsum Drywall Screws
2 Outer layer of Gyproc plasterboard or Glasroc F specialist board 6 Gyproc plasterboard or Glasroc F specialist board
3 Gypframe GFS1 Fixing Strap 7 Gypframe 'C' Stud
4 Gypframe metal framing 8 Gypframe GFT1 Fixing T (alternatively use Gypframe GSF1 Fixing Strap)
GypWall classic
A highly versatile metal stud partition system
Partitions
through a combination of interchangeable
Gyproc plasterboards, Gypframe metal,
System can be skim
Thistle finish plasters and Saint-Gobain Isover finished with
ThistlePro PureFinish.
insulation
C04
Refer to C02. S01. P49
GypWall robust
Need a higher Duty Rating to BS 5234? GypWall robust provides Severe Duty Rating with a single
layer of board.
Refer to C04. S03. P02.
ShaftWall
Where access is limited to one side only, for example risers, lift shafts, corridors and stair cores,
ShaftWall provides the answer.
Refer to C05. S02. P02.
1 2
One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy the requirements of BS 476: Part 8: 1972 or BS 476: Part 22: 1987
1 2 3
One layer of board each side of 48mm One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
1 2 3
One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe ‘C’ Studs at 600mm Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 2b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3
One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty rating Approx. System reference
thickness type thickness height1 Rw dB weight
mm mm mm kg/m²
C04
Any2 Skim3 Any32 Skim3
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
1 2 3 4
One layer of board each side of One layer of board each side of 70mm One layer of board each side of One layer of board each side of
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 70mm Gypframe 70 AS 50 AcouStuds 70mm Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm Isover Acoustic at 600mm centres. 50mm 600mm centres. 3 x 25mm
Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 3b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3 4
One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 600mm centres. 3 x 25mm
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
C04
Any2 Skim3 Any2 Skim3
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
1 2 3
One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
4 5
Partitions
One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.
C04
Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 4b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3
One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
4 5
Partitions
One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.
C04
Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection
criteria).
1 2 3 4
One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 5b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3 4
One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
C04
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2
Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 6b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2
Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
1 2 3
Two layers of board each side of 70mm Two layers of board each side of 70mm Two layers of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 7b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3
Two layers of board each side of 70mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres.
Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200) 50mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2
Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 8b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2
Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2 3 4
Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 600mm
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm centres. 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 9b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3 4
Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of 92mm
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
thickness type thickness height1 Rw (Rw + Ctr) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
5
2 x 12.5mm lining thickness is acceptable for 120 minutes BS up to a maximum height of 5700mm but acoustic test data is not available.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2 3 4
Two layers of board each side of Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
2 144 Gyproc SoundBloc 2 x 12.5 5000 57 (51) 58 (51) Severe 45 A206A290 A206A290S
3 144 Gyproc SoundBloc 2 x 12.5 5000 58 (53) 59 (53) Severe 45 A206A291 A206A291S
4 144 Gyproc SoundBloc 2 x 12.5 5000 59 (54) 60 (54) Severe 45 A206A292 A206A292S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 10b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3 4
Two layers of board each side Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only
2 144 Gyproc SoundBloc 2 x 12.5 5800 57 (51) 58 (51) Severe 45 A206A290 A206A290S
3 144 Gyproc SoundBloc 2 x 12.5 5800 58 (53) 59 (53) Severe 45 A206A291 A206A291S
4 144 Gyproc SoundBloc 2 x 12.5 5800 59 (54) 60 (54) Severe 45 A206A292 A206A292S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2 3
Two layers of board each side of 146mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm
Partitions
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
C04
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only
2 198 Gyproc SoundBloc 2 x 12.5 4000 55 (49) 56 (49) Severe 43 A206210 A206210S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
GypWall classic
For details of when
to specify fire
146mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 11b — Solutions to satisfy the requirements of BS 476: Part 8: 1972 or BS 476: Part 22: 1987
1 2 3
Two layers of board each side of 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm
Partitions
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
C04
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only
2 198 Gyproc SoundBloc 2 x 12.5 7600 55 (49) 56 (49) Severe 43 A206210 A206210S
3 198 Gyproc SoundBloc 2 x 12.5 7600 56 (50) 57 (50) Severe 43 A206244 A206244S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
1 2 3
Two layers of board each sideof 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe 146 AS 50 AcouStuds at Gypframe 146 AS 50 AcouStuds at 600mm centres. Gypframe 146 AS 50 AcouStuds at 600mm centres.
Partitions
600mm centres. Linings as in table. 50mm Isover Acoustic Partition Roll (APR 1200) 150mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. (100mm and 50mm) in the cavity.
Linings as in table.
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S
1 198 Gyproc FireLine 2 x 12.5 4200 52 (48) 53 (48) Severe 40 A206A091 A206A091S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.
GypWall classic
For details of when
to specify fire
146mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 12b — Solutions to satisfy the requirements of BS 476: Part 22: 1987
1 2 3
Partitions
of 146mm Gypframe 146 AS 50 AcouStuds 146 AS 50 AcouStuds at 600mm centres. 50mm
150mm Isover Acoustic Partition Roll (APR 1200)
at 600mm centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200)
(100mm and 50mm) in the cavity.
in the cavity. Linings as in table.
Linings as in table.
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04
thickness type thickness partition Rw (Rw + Ctr ) dB rating weight
mm mm height1 Any2 Skim3 kg/m² Any2 Skim3
mm finish only finish only
1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S
For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).
For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.
Whilst our GypWall partition systems are non-loadbearing, they Where services such as horizontal ducts, fire dampers and access
are able to provide resistance to levels of horizontal uniformly panels are required to penetrate the wall, their position should be
distributed loads in accordance with BS 6399. pre-determined in order that a framed opening can be provided.
The openings should be constructed using established metal stud
Refer to C02. S01. P26 – Robustness.
procedures.
Planning – key factors Refer to Partitions introduction C04. S01. P16 - construction
details 28-31.
GypWall classic comprises Gypframe 'C' Studs installed at 600mm
centres within Gypframe Floor & Ceiling Channels. The position
Cavity barriers
of services and heavy fixtures should be pre-determined and their
installation planned into the frame erection stage. Minimum 12.5mm Gyproc plasterboard, screw-fixed into the web
Partitions
Gypframe Floor & Ceiling Channels must be securely fixed with a Refer to C06. S07. P02 – Cavity barriers.
row of fixings at 600mm maximum centres. For 94mm and 148mm
channels, two rows of staggered fixings are required, each row at
C04
Control joints
600mm centres and each fixing 25mm in from the flange. If the
Control joints may be required in the partition to relieve stresses
floor is uneven, a 38mm thick timber sole plate equal to the width
induced by expansion and contraction of the structure (refer to
of the channel should be used.
Partitions introduction C04. S01. P10 – construction detail 12). They
should coincide with movement joints within the surrounding
If the concrete or screeded floor is new, consideration should be
structure.
given to the installation of a damp-proof membrane between the
floor surface and the channel or sole plate.
Deflection heads
Partition to structural steelwork junctions Refer to C02. S01. P10 – Building acoustics.
Electrical
The installation of electrical services should be carried out in
accordance with BS 7671. The cut-outs in the studs can be used Handy hint
for routing electrical and other small services (refer to Partitions
introduction C04. S01. P07 – construction detail 2). Switch boxes For alternative stud types and / or reduced
and socket outlets can be supported from Gypframe 99 FC 50 Fixing centres, to increase maximum partition
Channel fixed horizontally between studs, or a high performance height, further options are available.
socket box detail used where higher acoustic performance is Refer to C04. S01. P05, table 2.
required.
Partitions
in Partitions introduction C04. S01. P07 – construction detail 2a
for conventional cut-outs. Cables should be protected by conduit,
SpecSure®
or other suitable precautions taken to prevent abrasion when they
All our systems are covered by SpecSure® when
pass through the metal frame. Service cut-outs should be aligned to
using genuine British Gypsum and Saint-Gobain
allow easy installation of service. If studs require cutting, cut from
Isover products.
C04
the same end of each stud to ensure cut-out alignment.
Independent support
Fixtures
Board finishing
Tiling
Construction details
Gypframe ‘C’ Studs (48 S 50, 70 S 50, 92 S 50, Gypframe Extra Deep Flange Floor & Ceiling
146 S 50) Channels (50 EDC 70, 72 EDC 80, 94 EDC 70,
Vertical stud providing acoustic and structural 148 EDC 80)
performances designed to receive fixing of board Floor and ceiling channels with extra deep flanges
to both sides. for retaining the Gypframe studs at floor and
ceiling junctions for partitions over 8000mm high.
Also used around openings and in deflection heads
(maximum 50mm deflection).
Partitions
Gypframe ‘I’ Studs (70 I 50, 92 I 90, 146 I 80, Gypframe 99 FC 50 Fixing Channel
146 TI 90) A versatile metal fixing channel used to support
Enhanced strength stud that allows for increased medium weight fixtures on walls.
partition height, designed to receive fixing of board.
C04
Gypframe AcouStud (70 AS 50, 92 AS 50, 146 AS 50) Gypframe GFS1 Fixing Strap
Vertical stud providing enhanced acoustic and Used to support horizontal board joints and within
structural performances designed to receive deflection heads.
fixing of board to both sides.
Gypframe Folded Edge Standard Floor & Ceiling Gypframe GFT1 Fixing T
Channels (50 FEC 50, 72 FEC 50, 94 FEC 50, Used to support horizontal board joints.
148 FEC 50)
Standard floor and ceiling channels for retaining
the Gypframe studs at floor and ceiling junctions Gypframe GA6 Splayed Angle
and around openings to heights not exceeding Steel angle providing framing stability and
4200mm. board support.
Gypframe Deep Flange Floor & Ceiling Channels Gypframe Service Support Plate
(50 DC 60, 72 DC 60, 94 DC 60, 148 DC 60) For installation of 18mm plywood within
Floor and ceiling channels with deep flanges for a partition cavity to support medium to
retaining the Gypframe studs at floor and ceiling heavyweight fixtures.
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).
1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.
GypWall classic
Board products ( Refer to C10. S03. P02 for details)
Partitions
3
Glasroc H tilebacker is suitable for use in high moisture environments.
C04
Corrosion resistant self-tapping steel screws For fixing boards to Gypframe metal framing
for fixing board to metal framing less than 0.8mm thick or greater (‘I’ studs 0.6mm thick
0.8mm thick ('I' studs less than 0.6mm thick). and greater).
British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing 0.8mm thick or
0.8mm thick ('I' studs less than 0.6mm thick). greater ('I' studs 0.6mm thick or greater).
GypWall classic
Scan the image with this frame
for more information and
videos related to this system
This is intended to be a basic description of how the system is installed. Or visit gyp.sm/b/l2
For installation guidance refer to the British Gypsum Site Book.
Partitions
Appropriate Gypframe channels are suitably Gypframe 'C' Studs are suitably fixed to Gypframe studs are then friction fitted into
fixed to the floor and soffit. abutments. the Gypframe Floor & Ceiling Channels at
required centres.
C04
Door openings are constructed to suit the The perimeter of the partition is then sealed M&E services can be located within the
partitions' duty rating. on both sides with Gyproc Sealant. partition cavity.
Additional information
For full installation details, refer to the
British Gypsum Site Book, available to