White Book C04 S02 Partitions GypWall CLASSIC

Download as pdf or txt
Download as pdf or txt
You are on page 1of 51
At a glance
Powered by AI
The document discusses the GypWall classic partition system from British Gypsum, including its components, installation process, and compatible insulation and finishing products.

The main components of the GypWall classic partition system include Gypframe channels, studs, plasterboards, screws, jointing materials, beads and trims.

A GypWall classic partition is installed by fixing channels to the floor and ceiling, inserting studs into the channels, installing boards using screws, sealing joints, and adding insulation in the cavity if required.

!

This section includes updated information, added since it was first


published in December 2015.
Last updated 10/06/2019

C04. S02. P02 – P32


GypWall classic

Including C04. S01. P02 – P18
Partitions introduction
Introduction

Partitions
This section contains a full range of lightweight partition and wall
systems for use in new and existing buildings. They cover all applications,
from simple space division to high performance walls
Partitions
C04
Introduction
Partitions
British Gypsum offers a full range of lightweight
partition and wall systems. Our systems are
non-loadbearing and constructed using modern,
drylining techniques. British Gypsum metal
framed partitions and walls can be used in all
types of new and existing buildings, including
private and social housing, apartments,

Partitions
healthcare, educational facilities, recreational
and industrial properties.

C04
They cover all applications, from simple space
division, through to high performance walls
designed to meet the most demanding fire
resistance, sound insulation, impact and height
requirements.

British Gypsum partition systems are constructed


using lightweight materials, which can give rise to
significant savings in structural design compared
to masonry alternatives. Big benefits also include
the speed of installation and reduction to overall
build costs.

Buildings need to evolve throughout their life to


suit changing demands placed upon them. Our
lightweight partition systems are easy to reconfigure
with minimal impact to both building and occupants
resulting in less disruption, optimising the
transformation process.

You may also be interested in...


For unique performance situations with specialist requirements:
— Curved partitions — Access to build from one side only
— High levels of fire resistance — High security including bomb blast

Refer to C05. S01. P02 – Specialist partitions

0115 945 6123 [email protected] C04. S01. P02


Partitions
Introduction

When specifying partitions, a number of performance characteristics are normally used to determine the required solution.
Depending on the project or construction type, these performance parameters could be set by minimum regulatory
standards, or a client or customer requirement for buildings that offer the highest standards of performance and comfort.

Our quick-reference partition system guide, below, allows you to simply select the performance categories of interest and
identify the British Gypsum partitions systems that best satisfy your project requirements.

Duty Maximum
Fire rating height1
Partition
Acoustic performance
performance thickness System Page
Partitions

mins mm Rw dB Rw + Ctr dB BS 5234 mm

Medium -
30 - 120 75 - 211 34 - 63 47 - 57 8100 GypWall classic C04.S02.P02
Severe
C04

60 - 120 102 - 132 42 - 58 - Severe 4900 GypWall robust C04.S03.P02

GypWall extreme (including


30 - 60 97 - 203 44 - 62 - Severe 7800 C04.S04.P02
exreme / robust Hybrid)

60 - 120 137 - 238 61 - 65 53 - 59 Severe 6800 GypWall quiet sf C04.S05.P02

Heavy -
30 - 90 102 - 208 49 - 63 48 - 55 5700 GypWall staggered C04.S06.P02
Severe

60 - 120 200 - 300 60 - 64 47 - 58 Severe 7500 GypWall quiet C04.S07.P02

60 - 120 ≥200 66 - 70 58 - 62 Severe 3900 GypWall quiet iwl C04.S08.P02

60 - 120 300 - 800 67 - 80 56 - 71 Severe 11500 GypWall audio C04.S09.P02

30 75 - 102 40 - 46 - Medium 2700 GypWall rapid dB Plus C04.S10.P02

Non-loadbearing timber
30 - 120 88 - 196 34 - 52 - - - C04.S11.P02
stud (internal partitions)

Non-loadbearing timber
60 - 90 141 - 293 56 - 63 48 - 53 - - C04.S11.P05
stud (separating walls)

1
Based on studs at 600mm centres

Additional information
Try out The White Book System Selector, an online tool designed to help find the ideal solutions for your
project needs. Additional information such as BIM data (Revit), NBS clauses, CAD drawings and other
associated items can be downloaded. Visit british-gypsum.com

C04. S01. P03 british-gypsum.com


GypWall performance

Introduction
Acoustic performance
Table 1 — Sound insulation performance for residential specification
On-site Laboratory2
Approved Document E (England and Wales) Minimum solution Recommended solution
DnT,w + Ctr dB
(Rw + Ctr ) dB (Rw + Ctr ) dB

Separating walls between new homes 45 (49) (54)


Separating walls between purpose-built rooms for residential
43 (47) (52)
purposes and rooms created by a change of use or conversion

On-site Laboratory2

Partitions
Technical Standards Section 5 (Scotland) Minimum solution Recommended solution
DnT,w + Ctr dB
Rw dB Rw dB

Separating walls between new homes, purpose-built for residential


56 60 63
purposes and conversions (not including traditional buildings1)

Separating walls between rooms created by a change of use


53 57 60

C04
or conversion (traditional buildings1)

1
Definition of traditional buildings - A building or part of a building of a type constructed before or around 1919:
a) using construction techniques that were commonly in use before 1919; and
b) with permeable components, in a way that promotes the dissipation of moisture from the building fabric.
2
Minimum solutions provide little or no margin of safety to allow for reduction in performance due to flanking transmission. Recommended solutions have
greater potential to satisfy the requirements of Building regulations.

Good practice specification guidance


British Gypsum’s systems are designed and tested to meet — Consider flanking transmission at the design stage and
every performance requirement and are fully supported by ensure construction detailing is specified to eliminate,
our SpecSure® lifetime system warranty. or at least to minimise, any downgrading of the acoustic
performance
This means that when our systems are installed following
— Small openings such as gaps, cracks or holes will conduct
our guidance they will achieve every performance claim we
airborne sounds and can significantly reduce the sound
make, and if they don’t then we’ll put it right.
insulation of a construction. For optimum sound
insulation a construction must be airtight
To maximise the performance achieved on site, consider the
following good practice specification guidance: — When designing the layout of rooms requiring separation
by sound insulating walls abutting structural steelwork,
consideration should be given to the potential loss of
sound insulation performance through the steelwork
— Deflection heads, by definition, must be able to move
and, therefore, achieving an airtight seal is very difficult
without incorporating sophisticated components and
techniques. Air leakage at the partition heads will have a
detrimental effect on acoustic performance of any
partition. Where acoustic performance is a key
consideration, steps must be taken to minimise this loss
of performance
— A common mistake made when designing a building is to
specify a high performance element and then incorporate
a lower performing element within it; for example, a
door within a partition. Where the difference between
insulation is relatively small (7dB or less), there needs
to be a comparatively large area of the lower insulation
element before the overall sound insulation is
significantly affected. However, where there is a greater
difference in sound insulation performance between
the two elements, this would usually result in a greater
reduction of overall sound insulation performance

0115 945 6123 [email protected] C04. S01. P04


Standard GypWall performance
Introduction

Table 2 – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting deflection of L/240 at
200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
48 S 50 1 x 12.5mm 2500 2800 2900 3200 3100 3500
1 x 15mm 2800 3000 3100 3300 3300 3600
2 x 12.5mm 3400 3600 3600 3800 3800 4000
2 x 15mm 3700 3800 3900 4000 4000 4200
48 I 50 1 x 12.5mm 2900 - 3400 - 3700 -
1 x 15mm 3100 - 3500 - 3800 -
Partitions

2 x 12.5mm 3700 - 3900 - 4200 -


2 x 15mm 3900 - 4200 - 4400 -
60 S 50 1 x 12.5mm 3200 3400 3500 3800 3800 4200
1 x 15mm 3400 3600 3700 4000 4000 4300
C04

2 x 12.5mm 4100 4300 4300 4600 4600 4800


2 x 15mm 4400 4500 4600 4800 4800 5000
60 I 50 1 x 12.5mm 3600 - 4000 - 4400 -
1 x 15mm 3800 - 4200 - 4500 -
2 x 12.5mm 4400 - 4700 - 5000 -
2 x 15mm 4600 - 4900 - 5200 -
60 I 70 1 x 12.5mm 4100 - 4600 - 5000 -
1 x 15mm 4200 - 4700 - 5100 -
2 x 12.5mm 4700 - 5100 - 5500 -
2 x 15mm 4900 - 5300 - 5600 -
70 S 50 1 x 12.5mm 3600 3900 4000 4300 4300 4700
1 x 15mm 3800 4100 4200 4500 4500 4900
2 x 12.5mm 4600 4800 4900 5100 5100 5400
2 x 15mm 4900 5100 5100 5300 5300 5600
70 S 60 1 x 12.5mm 3800 4100 4200 4600 4500 5000
1 x 15mm 4000 4300 4400 4700 4700 5100
2 x 12.5mm 4700 4900 5000 5300 5200 5600
2 x 15mm 5000 5200 5200 5500 5500 5800
70 AS 50 1 x 12.5mm 3800 4200 4300 4700 4600 5100
1 x 15mm 4000 4400 4500 4800 4700 5200
2 x 12.5mm 4700 5000 5000 5300 5300 5700
2 x 15mm 5000 5200 5300 5600 5500 5900
70 I 50 1 x 12.5mm 4100 - 4600 - 5000 -
1 x 15mm 4300 - 4700 - 5100 -
2 x 12.5mm 4900 - 5300 - 5600 -
2 x 15mm 5200 - 5500 - 5800 -
70 I 70 1 x 12.5mm 4600 - 5100 - 5600 -
1 x 15mm 4700 - 5300 - 5700 -
2 x 12.5mm 5300 - 5700 - 6100 -
2 x 15mm 5500 - 5900 - 6300 -
92 S 50 1 x 12.5mm 4500 4800 4900 5400 5300 5800
1 x 15mm 4700 5100 5200 5600 5500 6000
2 x 12.5mm 5700 5900 6000 6300 6200 6600
2 x 15mm 5900 6100 6200 6500 6400 6800

In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.

For the affect on acoustic performance refer to C02. S01. P30.

C04. S01. P05 british-gypsum.com


Standard GypWall performance (continued)

Introduction
Table 2 (continued) – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting
deflection of L/240 at 200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to
EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
92 S 60 1 x 12.5mm 4700 5000 5200 5600 5600 6100
1 x 15mm 4900 5300 5400 5800 5800 6300
2 x 12.5mm 5800 6000 6100 6500 6500 6900
2 x 15mm 6000 6200 6300 6700 6600 7000
92 AS 50 1 x 12.5mm 4700 5100 5200 5700 5700 6200

Partitions
1 x 15mm 4900 5300 5400 5700 5800 6400
2 x 12.5mm 5800 6100 6200 6500 6500 6900
2 x 15mm 6000 6300 6400 6700 6700 7000
92 S 10 1 x 12.5mm 5300 5800 6000 6600 6500 7200
1 x 15mm 5500 6000 6100 6700 6600 7300

C04
2 x 12.5mm 6200 6600 6700 7200 7200 7700
2 x 15mm 6400 6800 6900 7400 7300 7800
92 I 90 1 x 12.5mm 6000 - 6800 - 7400 -
1 x 15mm 6200 - 6900 - 7500 -
2 x 12.5mm 6800 - 7400 - 7900 -
2 x 15mm 6900 - 7500 - 8000 -
146 S 50 1 x 12.5mm 6200 6800 6900 7600 7500 8300
1 x 15mm 6500 7000 7200 7800 7700 8400
2 x 12.5mm 7600 8000 8100 8600 8500 9100
2 x 15mm 7900 8200 8300 8800 8700 9300
146 AS 50 1 x 12.5mm 6600 7100 7300 8000 8000 8800
1 x 15mm 6800 7400 7600 8200 8200 8900
2 x 12.5mm 7800 8200 8400 8900 8900 9500
2 x 15mm 8100 8500 8600 9100 9100 9700
146 I 80 1 x 12.5mm 7900 - 8900 - 9700 -
1 x 15mm 8100 - 9000 - 9800 -
2 x 12.5mm 8800 - 9600 - 10400 -
2 x 15mm 9000 - 9800 - 10500 -
146 TI 90 1 x 12.5mm 8300 - 9400 - 10300 -
1 x 15mm 8400 - 9500 - 10400 -
2 x 12.5mm 9200 - 10100 - 10900 -
2 x 15mm 9400 - 10300 - 11100 -

In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.

For the affect on acoustic performance refer to C02. S01. P30.

0115 945 6123 [email protected] C04. S01. P06


Standard GypWall construction details
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

1 1a

1
3
5

5
Partitions

300mm
2
600mm

600mm

600mm
C04

2
300mm

6
7

Stud splicing detail Fully boxed Gypframe 'C' Stud

2 2a
Centres
at 600mm
Centres
at
thereafter
600mm
thereafter

1479mm
1479mm

50mm

50mm

50mm

75mm 75mm 75mm 75mm 75mm 28mm 28mm 28mm


38mm
38mm

38mm
30mm

38mm
879mm

879mm
279mm

279mm

70mm 92mm 146mm

48mm 60mm 70mm 146mm 70mm 92mm 146mm


92mm
stud stud stud stud AcouStud AcouStud AcouStud
stud

Service cut-outs - Gypframe ‘C’ and Gypframe ‘I’ Studs Service cut-outs - Gypframe AcouStuds

1 Gypframe 'I' Stud 5 British Gypsum Wafer Head Drywall Screws or


British Gypsum Wafer Head Jack-Point Screws
2 Gypframe 'C' Stud
6 Crimp
3 Gypframe AcouStud
7 Studs offset at top and bottom to facilitate engagement into channels
4 Gypframe Floor & Ceiling Channel

C04. S01. P07 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

3 3a

Partitions
11
4

3 6

3
1

C04
2 7

Base with timber sole plate

6
4

10

Head and base Junction with masonry and stop end detail

1 Gyproc plasterboard or Glasroc F specialist board 7 Floating screed on resilient layer


2 Gypframe 'C' Stud 8 Timber sole plate suitably fixed to structure
3 Gypframe Floor & Ceiling Channel 9 Internal blockwork
4 Gyproc Sealant 10 DriLyner basic wall lining system
5 Bulk fill Gyproc jointing materials (where gap exceeds 5mm) 11 Isover insulation
6 Skirting

0115 945 6123 [email protected] C04. S01. P08


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

5 6

2 1

3
Partitions

‘T’ Junction when partition with higher acoustic performance abuts


C04

a partition with lower acoustic performance. Acoustic principles


‘T’ junction - single layer only - detail may not be suitable for all solutions

7a 7b

2 2
1
1
4

3
3

‘T’ junction to optimise acoustic performance and reduce ‘T’ junction to optimise acoustic performance and reduce
flanking transmission flanking transmission

8 9

2 1

1
5

2
3

Four way junction to optimise acoustic performance and


reduce flanking transmission Splayed corner

1 Gyproc plasterboard or Glasroc F specialist board 4 Gypframe GA5 Internal Fixing Angle
2 Gypframe 'C' Stud 5 Gypframe GA6 Splayed Angle
3 Isover insulation

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

C04. S01. P09 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

10 11

1
1

2
2

Partitions
Corner detail - single layer Corner detail - double layer

C04
12 13

16
mm
12 12
mm mm
2

3
1

1
4

Gypframe 99 FC 50 Fixing Channel


Typical control joint (short legs flattened at stud positions)

14

Gypframe Service Support Plate

1 Gyproc plasterboard or Glasroc F specialist board 5 Gypframe 99 FC 50 Fixing Channel


2 Gypframe 'C' Stud 6 18mm plywood
3 Stone mineral wool (minimum density 23kg/m3) (by others) 7 Gypframe Service Support Plate
4 Gyproc Control Joint

Installing the screw into the side of the Gypframe Service Support Plate and the web of the Gypframe 'C' Stud will avoid creating excessive distortion to
the lining board.

0115 945 6123 [email protected] C04. S01. P10


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

15
15mm 7 16 15mm 7
15mm 6 15mm 6

4 4
20mm 15mm 10

3
11
2
1 2
1
Partitions

Deflection head for 15mm downward movement Deflection head for 15mm downward movement
and 60 minutes fire resistance and up to 120 minutes fire resistance

Not suitable for 60 minutes single layer systems on 48mm studs to Not suitable for 48mm studs to BS EN 1364-1
C04

BS EN 1364-1

17 7 18
7
25mm 50mm
8 8

7
25mm 7 50mm

5 5

55mm
30mm

3
3
2
2
1
1

Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance and 60 minutes fire resistance

19 20 7
7
25mm 9
50mm
9
7
25mm 7
50mm
5 5

30mm
3 55mm

3
2 2
1 1

Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance and 60 minutes fire resistance

1 Gyproc plasterboard or Glasroc F specialist board 7 Gyproc FireStrip (continuous)


2 Gypframe 'C' Stud 8 Timber head plate suitably fixed to structure
3 Gypframe GFS1 Fixing Strap 9 25mm Glasroc F firecase
4 Gypframe Deep Flange Floor & Ceiling Channel 10 Stone mineral wool (by others)
5 Gypframe Extra Deep Flange Floor & Ceiling Channel 11 Nogging cut from Gypframe 'C' Stud
6 Gyproc CoreBoard

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap (or stud nogging in construction detail 16). Continuous Gyproc FireStrip must be installed as shown to
maintain fire performance. Where there is a need for a deflection head in a 90 minute wall, the 120 minute solution can be used (refer to construction detail 16)
or alternatively, please contact the British Gypsum Technical Advice Centre for further guidance.
To minimise loss in acoustic performance refer to C02 S01 P10 Acoustic performance of head details.

C04. S01. P11 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

21 2 22

5 7
2

9
5
8
15mm 6 15mm 6
15mm 15mm

3 3

15mm 10
15mm

Partitions
10

4
4

C04
1
1

Deflection head parallel to floor profile for 15mm downward Deflection head perpendicular to floor profile for 15mm downward
movement and up to 60 minutes fire resistance 1 movement and up to 60 minutes fire resistance

Not suitable for 60 minutes single layer systems on 48mm studs to Not suitable for 60 minutes single layer systems on 48mm studs to
BS EN 1364-1 BS EN 1364-1

23 24

12 12

13 13

1
1
4
4

11 11

14

Junction with external wall when acoustic performance is a key


Junction with external wall consideration - helps reduce flanking transmission

1 Gyproc plasterboard or Glasroc F specialist board 9 Gypframe 99 FC 50 Fixing Channel


2 Gyproc FireStrip (continuous line) 10 Gypframe GFS1 Fixing Strap fixed to studs with
3 Gypframe Deep Flange Floor & Ceiling Channels (DC) British Gypsum Wafer Head Drywall Screws
4 Gypframe 'C' Stud 11 Isover insulation
5 Gyproc Sealant 12 External facade
6 Gyproc CoreBoard 13 External wall frame stud / by other(s)
7 Fire-stopping (by others) 14 Cavity barrier (subject to regulatory requirements)
8 Glasroc F firecase

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap. Continuous Gyproc FireStrip must be installed as shown to maintain fire performance.

1
To minimise acoustic downgrade, install Isover insulation within the hollow rib void.

0115 945 6123 [email protected] C04. S01. P12


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

25
Partitions

150mm
4
C04

1200mm 1200mm

Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Light and Medium Duty (up to 35kg door)

1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel 7 Timber sub-frame
4 Gypframe Floor & Ceiling Channel cut and bent to form door head

Advice should be sought from the door manufacturer prior to the construction of these details.

C04. S01. P13 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

26

150mm

Partitions
4

C04
3

2
300mm

1200mm 1200mm

150mm

Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel to sleeve studs 7 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head

Advice should be sought from the door manufacturer prior to the construction of these details.

At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws. The
studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.

0115 945 6123 [email protected] C04. S01. P14


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

27

8
7
Partitions

150mm
4
C04

2
300mm

1200mm 1200mm 1200mm

150mm

Alternative door frame for fixed partition heads only (maximum 1200mm width) to satisfy
BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc plasterboard or Glasroc F specialist board 6 Gypframe 'C' Stud to maintain stud module
2 Gypframe 'C' Stud 7 Gypframe 'C' Studs fixed back to back with
British Gypsum Drywall Screws at 300mm centres staggered
3 Gypframe Floor & Ceiling Channel to sleeve studs
8 Plasterboard infill (same type as lining) cut to fit between studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head
9 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
5 Timber door frame and architrave

Advice should be sought from the door manufacturer prior to the construction of these details.

At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws.
The studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.
The principle of this alternative detail is only suitable for GypWall classic, GypWall robust and GypWall extreme for fixed head situations only.

C04. S01. P15 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

28

3
1

Partitions
150mm
4

C04
5

150mm

Openings 1201 - 3300mm wide, for example double doors or large windows

1 Gypframe 'C' Stud 6 Centre stud required for margin up to 600mm between openings
2 Stud sleeved to full opening height with Gypframe Floor & Ceiling Channel 7 Partition between openings, minimum 600mm for Gypframe 'C' Studs
3 Gypframe studs (appropriate to system) (minimum 300mm for Gypframe 'I' Studs)

4 Gypframe Extra Deep Flange Floor & Ceiling Channel 8 Maximum distance 2400mm (if exceeds 2400mm contact British Gypsum
Technical Advice Centre)
5 Gypframe stud insert

0115 945 6123 [email protected] C04. S01. P16


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

29 30

Elevation

4
X

Y
Partitions

2
C04

2
Section X - X

1
Fire tested construction in which the damper is supported
3 by the partition (isometric view)

4 31

150mm
6
Section Y - Y

Opening for service penetrations in fire-rated partitions Opening up to 600mm wide for services

1 Gyproc plasterboard or Glasroc F specialist board 5 Damper (by others). Weight of damper should not exceed 57kg.
2 Gypframe 'C' Stud Size of damper should not exceed 1400 x 1200mm

3 Gypframe Floor & Ceiling Channel 6 Gypframe Folded Edge Standard Floor & Ceiling Channel cut and bent
to form opening head and cill
4 Penetration seal if required (refer to damper manufacturer for details)

C04. S01. P17 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

32

Partitions
5

C04
2

Board layout - typical configuration

33 34

2 6

7 7

Horizontal board joint - double layer Horizontal board joint - single layer

1 Inner layer of Gyproc plasterboard or Glasroc F specialist board 5 British Gypsum Drywall Screws
2 Outer layer of Gyproc plasterboard or Glasroc F specialist board 6 Gyproc plasterboard or Glasroc F specialist board
3 Gypframe GFS1 Fixing Strap 7 Gypframe 'C' Stud
4 Gypframe metal framing 8 Gypframe GFT1 Fixing T (alternatively use Gypframe GSF1 Fixing Strap)

0115 945 6123 [email protected] C04. S01. P18


GypWall classic

GypWall classic
A highly versatile metal stud partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall classic
GypWall classic
GypWall classic is the industry’s original 30 120
lightweight non-loadbearing drywall partition mins

system, providing cost-effective, multi-purpose


solutions suitable for all types of buildings.
34 63
Key benefits Rw dB

— Wide range of performances achievable

Partitions
through a combination of interchangeable
Gyproc plasterboards, Gypframe metal,
System can be skim
Thistle finish plasters and Saint-Gobain Isover finished with
ThistlePro PureFinish.
insulation

C04
Refer to C02. S01. P49

— Optimised acoustic performance for a given


footprint through the use of Gypframe AcouStuds
— Quick to install compared to masonry or timber Refer to C01. S01. P07

frame alternatives and allows transformation


of building layouts with minimal disruption
— Non-hygroscopic Gypframe metal framework
will not twist, warp or rot
— Easy accommodation of services within the
stud cavity due to pre-cut service holes within
the Gypframe metal studs

You may also be interested in...


GypWall rapid dB Plus
Constructing an internal wall within low rise housing? GypWall rapid dB Plus is particularly
suitable for projects where speed of installation and floor area maximisation are key priorities.
Refer to C04. S10. P02.

GypWall robust
Need a higher Duty Rating to BS 5234? GypWall robust provides Severe Duty Rating with a single
layer of board.
Refer to C04. S03. P02.

ShaftWall
Where access is limited to one side only, for example risers, lift shafts, corridors and stair cores,
ShaftWall provides the answer.
Refer to C05. S02. P02.

0115 945 6123 [email protected] C04. S02. P02


GypWall classic performance
GypWall classic

For details of when


to specify fire
48mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 75 Gyproc WallBoard 1 x 12.5 2500 34 - Medium 18 A206001 -

1 75 Glasroc H tilebacker 1 x 12.5 2500 34 - Medium 22 H206001 -

1 75 Gyproc SoundBloc 1 x 12.5 2500 37 - Medium 22 A206152 -

2 75 Gyproc WallBoard 1 x 12.5 2500 40 - Medium 18 A206033 -

2 75 Glasroc H tilebacker 1 x 12.5 2500 40 - Medium 22 H206033 -

2 75 Gyproc SoundBloc 1 x 12.5 2500 43 - Medium 22 A206184 -

1 80 Gyproc WallBoard 1 x 15 2800 36 - Medium 22 A206002 -

1 80 Gyproc SoundBloc 1 x 15 2800 39 - Medium 26 A206153 -

2 80 Gyproc WallBoard 1 x 15 2800 42 - Medium 22 A206034 -

2 80 Gyproc SoundBloc 1 x 15 2800 44 45 Medium 26 A206185 A206185S

60 minutes fire resistance

1 75 Glasroc F multiboard 1 x 12.5 2500 36 - Severe 25 G106010 -

1 80 Gyproc FireLine 1 x 15 2800 36 - Heavy 24 A206066 -

1 80 Gyproc SoundBloc f 1 x 15 2800 39 - Heavy 27 A206299 -

2 80 Gyproc FireLine 1 x 15 2800 42 - Heavy 24 A206098 -

2 80 Gyproc SoundBloc f 1 x 15 2800 44 45 Heavy 27 A206300 A206300S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P03 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy the requirements of BS 476: Part 8: 1972 or BS 476: Part 22: 1987

1 2 3

One layer of board each side of 48mm One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

30 minutes fire resistance

1 70 Glasroc F multiboard 1 x 10 2500 35 - Heavy 20 G106006 -

1 75 Gyproc WallBoard 1 x 12.5 2500 34 - Medium 18 A206001 -

1 75 Glasroc H tilebacker 1 x 12.5 2500 34 - Medium 22 H206001 -

1 75 Gyproc SoundBloc 1 x 12.5 2500 37 - Medium 22 A206152 -

2 75 Gyproc WallBoard 1 x 12.5 2500 40 - Medium 18 A206033 -

2 75 Glasroc H tilebacker 1 x 12.5 2500 40 - Medium 22 H206033 -

2 75 Gyproc SoundBloc 1 x 12.5 2500 43 - Medium 22 A206184 -

1 80 Gyproc WallBoard 1 x 15 2800 36 - Medium 22 A206002 -

1 80 Gyproc SoundBloc 1 x 15 2800 39 - Medium 26 A206153 -

2 80 Gyproc WallBoard 1 x 15 2800 42 - Medium 22 A206034 -

2 80 Gyproc SoundBloc 1 x 15 2800 44 45 Medium 26 A206185 A206185S

60 minutes fire resistance

3 70 Glasroc F multiboard 1 x 10 2500 43 - Heavy 20 G106008 -

1 75 Glasroc F multiboard 1 x 12.5 2500 36 - Severe 25 G106010 -

1 80 Gyproc FireLine 1 x 15 2800 36 - Heavy 24 A206066 -

1 80 Gyproc SoundBloc f 1 x 15 2800 39 - Heavy 27 A206299 -

2 80 Gyproc FireLine 1 x 15 2800 42 - Heavy 24 A206098 -

2 80 Gyproc SoundBloc f 1 x 15 2800 44 45 Heavy 27 A206300 A206300S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 [email protected] C04. S02. P04


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 2a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe ‘C’ Studs at 600mm Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
C04

Any2 Skim3 Any2 Skim3


finish only finish only

30 minutes fire resistance

1 97 Gyproc WallBoard 1 x 12.5 3600 36 - Medium 18 A206013 -

1 97 Glasroc H tilebacker 1 x 12.5 3600 36 - Medium 22 H206013 -

1 97 Gyproc SoundBloc 1 x 12.5 3600 40 - Medium 22 A206164 -

2 97 Gyproc WallBoard 1 x 12.5 3600 42 - Medium 18 A206045 -

2 97 Glasroc H tilebacker 1 x 12.5 3600 42 - Medium 22 H206045 -

3 97 Gyproc WallBoard 1 x 12.5 3600 43 - Medium 19 A206138 -

3 97 Glasroc H tilebacker 1 x 12.5 3600 43 - Medium 23 H206138 -

2 97 Gyproc SoundBloc 1 x 12.5 3600 45 - Medium 22 A206196 -

3 97 Gyproc SoundBloc 1 x 12.5 3600 47 - Medium 22 A206228 -

1 102 Gyproc WallBoard 1 x 15 3800 38 39 Medium 22 A206014 A206014S

1 102 Gyproc SoundBloc 1 x 15 3800 42 - Heavy 26 A206165 -

2 102 Gyproc WallBoard 1 x 15 3800 43 44 Medium 22 A206046 A206046S

3 102 Gyproc WallBoard 1 x 15 3800 44 45 Medium 22 A206139 A206139S

2 102 Gyproc SoundBloc 1 x 15 3800 47 48 Heavy 26 A206197 A206197S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 3800 37 - Heavy 24 A206078 -

1 102 Gyproc SoundBloc f 1 x 15 3800 42 - Heavy 27 A206301 -

2 102 Gyproc FireLine 1 x 15 3800 43 44 Heavy 24 A206110 A206110S

3 102 Gyproc FireLine 1 x 15 3800 44 45 Heavy 24 A206141 A206141S

2 102 Gyproc SoundBloc f 1 x 15 3800 47 48 Heavy 27 A206302 A206302S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P05 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 2b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty rating Approx. System reference
thickness type thickness height1 Rw dB weight
mm mm mm kg/m²

C04
Any2 Skim3 Any32 Skim3
finish only finish only

30 minutes fire resistance

1 97 Gyproc WallBoard 1 x 12.5 3600 36 - Medium 18 A206013 -

1 97 Glasroc H tilebacker 1 x 12.5 3600 36 - Medium 22 H206013 -

1 97 Gyproc SoundBloc 1 x 12.5 3600 40 - Medium 22 A206164 -

2 97 Gyproc WallBoard 1 x 12.5 3600 42 - Medium 18 A206045 -

2 97 Glasroc H tilebacker 1 x 12.5 3600 42 - Medium 22 H206045 -

3 97 Gyproc WallBoard 1 x 12.5 3600 43 - Medium 19 A206138 -

3 97 Glasroc H tilebacker 1 x 12.5 3600 43 - Medium 23 H206138 -

2 97 Gyproc SoundBloc 1 x 12.5 3600 45 - Medium 22 A206196 -

3 97 Gyproc SoundBloc 1 x 12.5 3600 47 - Medium 22 A206228 -

1 102 Gyproc WallBoard 1 x 15 3800 38 39 Medium 22 A206014 A206014S

1 102 Gyproc SoundBloc 1 x 15 3800 42 - Heavy 26 A206165 -

2 102 Gyproc WallBoard 1 x 15 3800 43 44 Medium 22 A206046 A206046S

3 102 Gyproc WallBoard 1 x 15 3800 44 45 Medium 22 A206139 A206139S

2 102 Gyproc SoundBloc 1 x 15 3800 47 48 Heavy 26 A206197 A206197S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 3800 37 - Heavy 24 A206078 -

1 102 Gyproc SoundBloc f 1 x 15 3800 42 - Heavy 27 A206301 -

2 102 Gyproc FireLine 1 x 15 3800 43 44 Heavy 24 A206110 A206110S

3 102 Gyproc FireLine 1 x 15 3800 44 45 Heavy 24 A206141 A206141S

2 102 Gyproc SoundBloc f 1 x 15 3800 47 48 Heavy 27 A206302 A206302S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 [email protected] C04. S02. P06


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 3a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of One layer of board each side of 70mm One layer of board each side of One layer of board each side of
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 70mm Gypframe 70 AS 50 AcouStuds 70mm Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm Isover Acoustic at 600mm centres. 50mm 600mm centres. 3 x 25mm
Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 97 Gyproc SoundBloc 1 x 12.5 3800 41 - Medium 22 A206A164 -

3 97 Gyproc WallBoard 1 x 12.5 3800 44 - Medium 19 A206A138 -

2 97 Gyproc SoundBloc 1 x 12.5 3800 48 - Medium 22 A206A196 -

3 97 Gyproc SoundBloc 1 x 12.5 3800 49 50 Medium 23 A206A228 A206A228S

1 102 Gyproc WallBoard 1 x 15 4000 38 39 Medium 22 A206A014 A206A014S

4 102 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 26 A206A252 A206A252S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 4000 39 40 Heavy 24 A206A078 A206A078S

1 102 Gyproc SoundBloc f 1 x 15 4000 42 - Heavy 27 A206A301 -

2 102 Gyproc FireLine 1 x 15 4000 43 44 Heavy 24 A206A110 A206A110S

3 102 Gyproc FireLine 1 x 15 4000 44 45 Heavy 24 A206A141 A206A141S

2 102 Gyproc SoundBloc f 1 x 15 4000 48 - Heavy 27 A206A302 -

4 102 Gyproc SoundBloc f 1 x 15 3000 50 51 Heavy 27 A206A304 A206A304S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P07 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 3b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 600mm centres. 3 x 25mm
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²

C04
Any2 Skim3 Any2 Skim3
finish only finish only

30 minutes fire resistance

1 97 Gyproc SoundBloc 1 x 12.5 3800 41 - Medium 22 A206A164 -

3 97 Gyproc WallBoard 1 x 12.5 3800 44 - Medium 19 A206A138 -

2 97 Gyproc SoundBloc 1 x 12.5 3800 48 - Medium 22 A206A196 -

3 97 Gyproc SoundBloc 1 x 12.5 3800 49 50 Medium 23 A206A228 A206A228S

4 102 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 26 A206A252 A206A252S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 4000 39 40 Heavy 24 A206A078 A206A078S

1 102 Gyproc SoundBloc f 1 x 15 4000 42 - Heavy 27 A206A301 -

2 102 Gyproc FireLine 1 x 15 4000 43 44 Heavy 24 A206A110 A206A110S

3 102 Gyproc FireLine 1 x 15 4000 44 45 Heavy 24 A206A141 A206A141S

2 102 Gyproc SoundBloc f 1 x 15 4000 48 - Heavy 27 A206A302 -

4 102 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206A304 A206A304S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 [email protected] C04. S02. P08


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 4a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

4 5
Partitions

One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.
C04

Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3

30 minutes fire resistance

4 119 Gyproc SoundBloc 1 x 12.5 4000 50 51 Medium 23 A206232 A206232S

1 124 Gyproc SoundBloc 1 x 15 4000 44 45 Heavy 27 A206261 A206261S

2 124 Gyproc SoundBloc 1 x 15 4000 49 50 Heavy 27 A206262 A206262S

3 124 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 27 A206263 A206263S

5 124 Gyproc SoundBloc 1 x 15 4000 51 52 Heavy 27 A206264 A206264S

4 124 Gyproc SoundBloc 1 x 15 4000 52 53 Heavy 27 A206233 A206233S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4000 40 41 Heavy 25 A206265 A206265S

1 124 Gyproc SoundBloc f 1 x 15 4000 44 45 Heavy 27 A206305 A206305S

2 124 Gyproc FireLine 1 x 15 4000 44 4


45
4
Heavy 25 A206266 A206266S

5 124 Gyproc FireLine 1 x 15 4000 46 48 Heavy 25 A206268 A206268S

2 124 Gyproc SoundBloc f 1 x 15 4000 49 50 Heavy 27 A206306 A206306S

3 124 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206309 A206309S

5 124 Gyproc SoundBloc f 1 x 15 4000 51 52 Heavy 27 A206308 A206308S

4 124 Gyproc SoundBloc f 1 x 15 4000 52 53 Heavy 27 A206307 A206307S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P09 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 4b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

4 5

Partitions
One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.

C04
Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3

30 minutes fire resistance

4 119 Gyproc SoundBloc 1 x 12.5 4500 50 51 Medium 23 A206232 A206232S

1 124 Gyproc SoundBloc 1 x 15 4700 44 45 Heavy 27 A206261 A206261S

2 124 Gyproc SoundBloc 1 x 15 4700 49 50 Heavy 27 A206262 A206262S

3 124 Gyproc SoundBloc 1 x 15 4700 50 51 Heavy 27 A206263 A206263S

5 124 Gyproc SoundBloc 1 x 15 4700 51 52 Heavy 27 A206264 A206264S

4 124 Gyproc SoundBloc 1 x 15 4700 52 53 Heavy 27 A206233 A206233S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4700 40 41 Heavy 25 A206265 A206265S

1 124 Gyproc SoundBloc f 1 x 15 4700 44 45 Heavy 27 A206305 A206305S

2 124 Gyproc FireLine 1 x 15 4700 444 454 Heavy 25 A206266 A206266S

5 124 Gyproc FireLine 1 x 15 4700 46 48 Heavy 25 A206268 A206268S

2 124 Gyproc SoundBloc f 1 x 15 4700 49 50 Heavy 27 A206306 A206306S

3 124 Gyproc SoundBloc f 1 x 15 4700 50 51 Heavy 27 A206309 A206309S

5 124 Gyproc SoundBloc f 1 x 15 4700 51 52 Heavy 27 A206308 A206308S

4 124 Gyproc SoundBloc f 1 x 15 4700 52 53 Heavy 27 A206307 A206307S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection
criteria).

0115 945 6123 [email protected] C04. S02. P10


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 5a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
C04

mm mm mm Any2 Skim3 kg/m² Any2 Skim3


finish only finish only

30 minutes fire resistance

1 124 Gyproc SoundBloc 1 x 15 4000 45 46 Heavy 27 A206A281 A206A281S

2 124 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 27 A206A282 A206A282S

3 124 Gyproc SoundBloc 1 x 15 4000 51 52 Heavy 27 A206A283 A206A283S

4 124 Gyproc SoundBloc 1 x 15 4000 52 54 Heavy 27 A206A284 A206A284S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4000 41 42 Heavy 24 A206A285 A206A285S

2 124 Gyproc FireLine 1 x 15 4000 444 454 Heavy 24 A206A286 A206A286S

1 124 Gyproc SoundBloc f 1 x 15 4000 45 46 Heavy 27 A206A305 A206A305S

4 124 Gyproc FireLine 1 x 15 4000 46 48 Heavy 24 A206A288 A206A288S

2 124 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206A306 A206A306S

3 124 Gyproc SoundBloc f 1 x 15 4000 51 52 Heavy 27 A206A309 A206A309S

4 124 Gyproc SoundBloc f 1 x 15 4000 52 54 Heavy 27 A206A308 A206A308S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P11 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 5b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight

C04
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

30 minutes fire resistance

1 124 Gyproc SoundBloc 1 x 15 4900 45 46 Heavy 27 A206A281 A206A281S

2 124 Gyproc SoundBloc 1 x 15 4900 50 51 Heavy 27 A206A282 A206A282S

3 124 Gyproc SoundBloc 1 x 15 4900 51 52 Heavy 27 A206A283 A206A283S

4 124 Gyproc SoundBloc 1 x 15 4900 52 54 Heavy 27 A206A284 A206A284S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4900 41 42 Heavy 24 A206A285 A206A285S

2 124 Gyproc FireLine 1 x 15 4900 445 455 Heavy 24 A206A286 A206A286S

1 124 Gyproc SoundBloc f 1 x 15 4900 45 46 Heavy 27 A206A305 A206A305S

4 124 Gyproc FireLine 1 x 15 4900 46 48 Heavy 24 A206A288 A206A288S

2 124 Gyproc SoundBloc f 1 x 15 4900 50 51 Heavy 27 A206A306 A206A306S

3 124 Gyproc SoundBloc f 1 x 15 4900 51 52 Heavy 27 A206A309 A206A309S

4 124 Gyproc SoundBloc f 1 x 15 4900 52 54 Heavy 27 A206A308 A206A308S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P12


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
48mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 6a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 100 Gyproc WallBoard 2 x 12.5 3400 42 - Severe 35 A206003 -

Outer layer Glasroc H tilebacker 1 x 12.5


1 100 3400 42 - Severe 39 H206003 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 100 Gyproc WallBoard 2 x 12.5 3000 49 - Severe 35 A206035 -
Outer layer Glasroc H tilebacker 1 x 12.5
2 100 3000 49 - Severe 39 H206035 -
+ inner layer Gyproc WallBoard + 1 x 12.5

60 minutes fire resistance

1 100 Gyproc SoundBloc 2 x 12.5 3000 46 - Severe 43 A206154 -

2 100 Gyproc SoundBloc 2 x 12.5 3000 51 - Severe 43 A206186 -

1 110 Gyproc WallBoard 2 x 15 3700 45 - Severe 42 A206004 -

90 minutes fire resistance

1 100 Gyproc FireLine 2 x 12.5 3400 42 - Severe 40 A206067 -

1 110 Gyproc SoundBloc 2 x 15 3000 49 - Severe 51 A206155 -

2 110 Gyproc SoundBloc 2 x 15 3000 53 54 Severe 51 A206187 A206187S

120 minutes fire resistance

1 100 Gyproc FireLine 2 x 12.5 3000 42 - Severe 40 A206067 -

2 100 Gyproc FireLine 2 x 12.5 3000 49 - Severe 40 A206099 -

1 110 Gyproc FireLine 2 x 15 3700 45 - Severe 49 A206156 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P13 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 6b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2

Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 100 Gyproc WallBoard 2 x 12.5 3400 42 - Severe 35 A206003 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 100 3400 42 - Severe 39 H206003 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 100 Gyproc SoundBloc 2 x 12.5 3400 46 - Severe 43 A206154 -

2 100 Gyproc WallBoard 2 x 12.5 3400 49 - Severe 35 A206035 -


Outer layer Glasroc H tilebacker 1 x 12.5
2 100 3400 49 - Severe 39 H206035 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 100 Gyproc SoundBloc 2 x 12.5 3400 51 - Severe 43 A206186 -

90 minutes fire resistance

1 110 Gyproc WallBoard 2 x 15 3700 45 - Severe 42 A206004 -

1 110 Gyproc SoundBloc 2 x 15 3700 49 - Severe 51 A206155 -

2 110 Gyproc WallBoard 2 x 15 3700 49 - Severe 42 A206036 -

2 110 Gyproc SoundBloc 2 x 15 3700 53 54 Severe 51 A206187 A206187S

120 minutes fire resistance

1 100 Gyproc FireLine 2 x 12.5 3400 42 - Severe 40 A206067 -

2 100 Gyproc FireLine 2 x 12.5 3400 49 - Severe 40 A206099 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 [email protected] C04. S02. P14


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 7a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each side of 70mm Two layers of board each side of 70mm Two layers of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4600 45 - Severe 35 A206015 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 122 4600 45 - Severe 39 H206015 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc WallBoard 2 x 12.5 4600 49 - Severe 35 A206047 -

60 minutes fire resistance

1 122 Gyproc SoundBloc 2 x 12.5 4600 49 - Severe 43 A206166 -

3 122 Gyproc WallBoard 2 x 12.5 4000 50 - Severe 35 A206142 -


Outer layer Glasroc H tilebacker 1 x 12.5
3 122 4000 50 - Severe 39 H206142 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc SoundBloc 2 x 12.5 4000 52 - Severe 43 A206198 -

3 122 Gyproc SoundBloc 2 x 12.5 4000 53 - Severe 44 A206230 -

1 132 Gyproc WallBoard 2 x 15 4900 46 47 Severe 42 A206016 A206016S

2 132 Gyproc WallBoard 2 x 15 4000 50 - Severe 42 A206048 -

90 minutes fire resistance

1 132 Gyproc SoundBloc 2 x 15 4000 51 52 Severe 51 A206167 A206167S

2 132 Gyproc SoundBloc 2 x 15 4000 54 55 Severe 51 A206199 A206199S

3 132 Gyproc SoundBloc 2 x 15 4000 56 57 Severe 52 A206231 A206231S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4200 46 - Severe 40 A206079 -

2 122 Gyproc FireLine 2 x 12.5 4000 49 - Severe 40 A206111 -

3 122 Gyproc FireLine 2 x 12.5 4000 50 - Severe 40 A206144 -

1 132 Gyproc FireLine 2 x 15 4900 46 47 Severe 47 A206251 A206251S

2 132 Gyproc FireLine 2 x 15 4300 50 - Severe 49 A206253 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P15 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 7b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 70mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres.
Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200) 50mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4600 45 - Severe 35 A206015 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 122 4600 45 - Severe 39 H206015 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 122 Gyproc SoundBloc 2 x 12.5 4600 49 - Severe 43 A206166 -

2 122 Gyproc WallBoard 2 x 12.5 4600 49 - Severe 35 A206047 -


Outer layer Glasroc H tilebacker 1 x 12.5
2 122 4600 49 - Severe 39 H206047 -
+ inner layer Gyproc WallBoard + 1 x 12.5
3 122 Gyproc WallBoard 2 x 12.5 4600 50 - Severe 36 A206142 -
Outer layer Glasroc H tilebacker 1 x 12.5
3 122 4600 50 - Severe 39 H206142 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc SoundBloc 2 x 12.5 4600 52 - Severe 43 A206198 -

3 122 Gyproc SoundBloc 2 x 12.5 4600 53 - Severe 44 A206230 -

90 minutes fire resistance

1 132 Gyproc WallBoard 2 x 15 4900 46 47 Severe 42 A206016 A206016S

2 132 Gyproc WallBoard 2 x 15 4900 50 - Severe 42 A206048 -

1 132 Gyproc SoundBloc 2 x 15 4900 51 52 Severe 51 A206167 A206167S

2 132 Gyproc SoundBloc 2 x 15 4900 54 55 Severe 51 A206199 A206199S

3 132 Gyproc SoundBloc 2 x 15 4900 56 57 Severe 52 A206231 A206231S

120 minutes fire resistance

1 112 Glasroc F multiboard 2 x 10 4200 42 -- Severe 40 G106013 -

1 122 Gyproc FireLine 2 x 12.5 4600 46 - Severe 40 A206079 -

2 122 Gyproc FireLine 2 x 12.5 4600 49 - Severe 40 A206111 -

3 122 Gyproc FireLine 2 x 12.5 4600 50 - Severe 41 A206144 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P16


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 8a – Solutions to satisfy the requirements of BS EN 1364-1

1 2

Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4700 47 - Severe 35 A206A015 -

60 minutes fire resistance

1 122 Gyproc SoundBloc 2 x 12.5 4700 53 - Severe 43 A206A166 -

2 122 Gyproc SoundBloc 2 x 12.5 4000 58 59 Severe 43 A206A198 A206A198S

90 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4700 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4700 54 55 Severe 40 A206A111 A206A111S

1 132 Gyproc SoundBloc 2 x 15 4000 54 55 Severe 51 A206A167 A206A167S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4200 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4000 54 55 Severe 40 A206A111 A206A111S

1 132 Gyproc FireLine 2 x 15 5000 49 50 Severe 49 A206A251 A206A251S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P17 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 8b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2

Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4700 47 - Severe 35 A206A015 -

1 122 Gyproc SoundBloc 2 x 12.5 4700 53 - Severe 43 A206A166 -

2 122 Gyproc SoundBloc 2 x 12.5 4700 58 59 Severe 43 A206A198 A206A198S

90 minutes fire resistance

1 132 Gyproc SoundBloc 2 x 15 5000 54 55 Severe 51 A206A167 A206A167S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4700 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4700 54 55 Severe 40 A206A111 A206A111S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P18


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 9a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 600mm
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm centres. 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions

in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness height1 Rw (Rw + Ctr) dB rating weight


mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

3 144 Gyproc SoundBloc 2 x 12.5 4000 56 (51) - Severe 44 A206234 -

90 minutes fire resistance

1 154 Gyproc SoundBloc 2 x 15 5000 52 53 Severe 52 A206269 A206269S

4 154 Gyproc FireLine 2 x 15 4000 53 55 Severe 49 A206276 A206276S

2 154 Gyproc SoundBloc 2 x 15 5000 56 4


57 4
Severe 52 A206270 A206270S

120 minutes fire resistance

1 154 Gyproc FireLine 2 x 15 5900 50 51 Severe 48 A206273 A206273S

2 154 Gyproc FireLine 2 x 15 5000 52 4


53 4
Severe 48 A206274 A206274S

4 154 Gyproc FireLine 2 x 15 3000 53 55 Severe 49 A206276 A206276S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P19 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 9b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of 92mm
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.

Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness height1 Rw (Rw + Ctr) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only

60 minutes fire resistance

3 144 Gyproc SoundBloc 2 x 12.5 5700 56 (51) - Severe 44 A206234 -

90 minutes fire resistance

1 154 Gyproc SoundBloc 2 x 15 5900 52 53 Severe 52 A206269 A206269S

2 154 Gyproc SoundBloc 2 x 15 5900 564 574 Severe 52 A206270 A206270S

120 minutes fire resistance

1 154 Gyproc FireLine 2 x 155 5900 50 51 Severe 48 A206273 A206273S

2 154 Gyproc FireLine 2 x 15 5


5900 52 4
53 4
Severe 48 A206274 A206274S

4 154 Gyproc FireLine 2 x 155 5900 53 55 Severe 49 A206276 A206276S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
5
2 x 12.5mm lining thickness is acceptable for 120 minutes BS up to a maximum height of 5700mm but acoustic test data is not available.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P20


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 10a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

Two layers of board each side of Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions

in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight


mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

1 144 Gyproc SoundBloc 2 x 12.5 5000 54 55 Severe 44 A206A289 A206A289S

2 144 Gyproc SoundBloc 2 x 12.5 5000 57 (51) 58 (51) Severe 45 A206A290 A206A290S

3 144 Gyproc SoundBloc 2 x 12.5 5000 58 (53) 59 (53) Severe 45 A206A291 A206A291S

4 144 Gyproc SoundBloc 2 x 12.5 5000 59 (54) 60 (54) Severe 45 A206A292 A206A292S

120 minutes fire resistance

1 144 Gyproc FireLine 2 x 12.5 3000 51 52 Severe 41 A206A293 A206A293S

3 144 Gyproc FireLine 2 x 12.5 4000 55 56 Severe 42 A206A295 A206A295S

4 144 Gyproc FireLine 2 x 12.5 3000 56 58 Severe 42 A206A296 A206A296S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P21 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 10b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

Two layers of board each side Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.

Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

1 144 Gyproc SoundBloc 2 x 12.5 5800 54 55 Severe 44 A206A289 A206A289S

2 144 Gyproc SoundBloc 2 x 12.5 5800 57 (51) 58 (51) Severe 45 A206A290 A206A290S

3 144 Gyproc SoundBloc 2 x 12.5 5800 58 (53) 59 (53) Severe 45 A206A291 A206A291S

4 144 Gyproc SoundBloc 2 x 12.5 5800 59 (54) 60 (54) Severe 45 A206A292 A206A292S

120 minutes fire resistance

1 144 Gyproc FireLine 2 x 12.5 5800 51 52 Severe 41 A206A293 A206A293S

3 144 Gyproc FireLine 2 x 12.5 5800 55 56 Severe 42 A206A295 A206A295S

4 144 Gyproc FireLine 2 x 12.5 5800 56 58 Severe 42 A206A296 A206A296S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P22


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
146mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 11a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each side of 146mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm
Partitions

Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
C04

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

30 minutes fire resistance

1 198 Gyproc WallBoard 2 x 12.5 7600 50 51 Severe 35 A206027 A206027S


Outer layer Glasroc H tilebacker 1 x 12.5 +
1 198 7600 50 - Severe 39 H206027 -
+ inner layer Gyproc WallBoard 1 x 12.5

60 minutes fire resistance

3 198 Gyproc WallBoard 2 x 12.5 4000 51 52 Severe 36 A206149 A206149S


Outer layer Glasroc H tilebacker 1 x 12.5 +
3 198 4000 51 - Severe 40 H206149 -
+ inner layer Gyproc WallBoard 1 x 12.5
1 198 Gyproc SoundBloc 2 x 12.5 5000 53 54 Severe 43 A206178 A206178S

2 198 Gyproc SoundBloc 2 x 12.5 4000 55 (49) 56 (49) Severe 43 A206210 A206210S

1 208 Gyproc WallBoard 2 x 15 5000 50 - Severe 42 A206028 -

2 208 Gyproc WallBoard 2 x 15 4000 51 - Severe 42 A206060 -

90 minutes fire resistance

1 208 Gyproc SoundBloc 2 x 15 3000 56 (50) 57 (50) Severe 51 A206179 A206179S

3 208 Gyproc SoundBloc 2 x 15 4000 59 (53) 60 (53) Severe 52 A206243 A206243S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 4200 50 51 Severe 40 A206091 A206091S

2 198 Gyproc FireLine 2 x 12.5 4000 51 52 Severe 40 A206123 A206123S

1 208 Gyproc FireLine 2 x 15 7900 50 - Severe 46 A206180 -

2 208 Gyproc FireLine 2 x 15 7800 51 - Severe 46 A206181 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P23 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
146mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 11b — Solutions to satisfy the requirements of BS 476: Part 8: 1972 or BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm

Partitions
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

C04
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only

60 minutes fire resistance

1 198 Gyproc WallBoard 2 x 12.5 7600 50 51 Severe 35 A206027 A206027S


Outer layer Glasroc H tilebacker 1 x 12.5
1 198 7600 50 - Severe 39 H206027 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 198 Gyproc WallBoard 2 x 12.5 7600 51 52 Severe 35 A206059 A206059S
Outer layer Glasroc H tilebacker 1 x 12.5
2 198 7600 51 - Severe 39 H206059 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 198 Gyproc SoundBloc 2 x 12.5 7600 53 54 Severe 43 A206178 A206178S

2 198 Gyproc SoundBloc 2 x 12.5 7600 55 (49) 56 (49) Severe 43 A206210 A206210S

3 198 Gyproc SoundBloc 2 x 12.5 7600 56 (50) 57 (50) Severe 43 A206244 A206244S

90 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 7900 50 - Severe 42 A206028 -

2 208 Gyproc WallBoard 2 x 15 7900 51 - Severe 42 A206060 -

1 208 Gyproc SoundBloc 2 x 15 7900 56 (50) 57 (50) Severe 51 A206179 A206179S

2 208 Gyproc SoundBloc 2 x 15 7900 58 (52) - Severe 51 A206211 -

3 208 Gyproc SoundBloc 2 x 15 7900 59 (53) 60 (53) Severe 52 A206243 A206243S

120 minutes fire resistance

1 188 Glasroc F multiboard 2 x 10 7100 48 - Severe 40 G106014 -

1 198 Gyproc FireLine 2 x 12.5 7600 50 51 Severe 40 A206091 A206091S

2 198 Gyproc FireLine 2 x 12.5 7600 51 52 Severe 40 A206123 A206123S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 [email protected] C04. S02. P24


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
146mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 12a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each sideof 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe 146 AS 50 AcouStuds at Gypframe 146 AS 50 AcouStuds at 600mm centres. Gypframe 146 AS 50 AcouStuds at 600mm centres.
Partitions

600mm centres. Linings as in table. 50mm Isover Acoustic Partition Roll (APR 1200) 150mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. (100mm and 50mm) in the cavity.
Linings as in table.

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness partition Rw (Rw + Ctr ) dB rating weight


mm mm height1 Any2 Skim3 kg/m² Any2 Skim3
mm finish only finish only

60 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 5000 52 (47) 54 (47) Severe 42 A206A028 A206A028S

1 208 Gyproc SoundBloc 2 x 15 5000 59 (54) 60 (54) Severe 51 A206A179 A206A179S

3 208 Gyproc SoundBloc 2 x 15 5000 61 (57) 63 (57) Severe 53 A206A255 A206A255S

90 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S

1 208 Gyproc SoundBloc 2 x 15 4000 59 (54) 60 (54) Severe 51 A206A179 A206A179S

2 208 Gyproc SoundBloc 2 x 15 4000 61 (56) 62 (56) Severe 52 A206A243 A206A243S

3 208 Gyproc SoundBloc 2 x 15 4000 61 (57) 63 (57) Severe 53 A206A255 A206A255S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 4200 52 (48) 53 (48) Severe 40 A206A091 A206A091S

1 208 Gyproc FireLine 2 x 15 8100 52 (47) 54 (47) Severe 50 A206A180 A206A180S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.

C04. S02. P25 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
146mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 12b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 146mm


Two layers of board each side Two layers of board each side of 146mm Gypframe
Gypframe 146 AS 50 AcouStuds at 600mm centres.

Partitions
of 146mm Gypframe 146 AS 50 AcouStuds 146 AS 50 AcouStuds at 600mm centres. 50mm
150mm Isover Acoustic Partition Roll (APR 1200)
at 600mm centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200)
(100mm and 50mm) in the cavity.
in the cavity. Linings as in table.
Linings as in table.

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness partition Rw (Rw + Ctr ) dB rating weight
mm mm height1 Any2 Skim3 kg/m² Any2 Skim3
mm finish only finish only

90 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 8100 52 (47) 54 (47) Severe 42 A206A028 A206A028S

1 208 Gyproc SoundBloc 2 x 15 8100 59 (54) 60 (54) Severe 51 A206A179 A206A179S

2 208 Gyproc SoundBloc 2 x 15 8100 61 (56) 62 (56) Severe 52 A206A243 A206A243S

3 208 Gyproc SoundBloc 2 x 15 8100 61 (57) 63 (57) Severe 53 A206A255 A206A255S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.

0115 945 6123 [email protected] C04. S02. P26


GypWall classic design
GypWall classic

Building design Framing surround for openings

Whilst our GypWall partition systems are non-loadbearing, they Where services such as horizontal ducts, fire dampers and access
are able to provide resistance to levels of horizontal uniformly panels are required to penetrate the wall, their position should be
distributed loads in accordance with BS 6399. pre-determined in order that a framed opening can be provided.
The openings should be constructed using established metal stud
Refer to C02. S01. P26 – Robustness.
procedures.

Planning – key factors Refer to Partitions introduction C04. S01. P16 - construction
details 28-31.
GypWall classic comprises Gypframe 'C' Studs installed at 600mm
centres within Gypframe Floor & Ceiling Channels. The position
Cavity barriers
of services and heavy fixtures should be pre-determined and their
installation planned into the frame erection stage. Minimum 12.5mm Gyproc plasterboard, screw-fixed into the web
Partitions

of perimeter channels or vertical studs, will provide a satisfactory


Fixing floor and ceiling channels closure to flame or smoke.

Gypframe Floor & Ceiling Channels must be securely fixed with a Refer to C06. S07. P02 – Cavity barriers.
row of fixings at 600mm maximum centres. For 94mm and 148mm
channels, two rows of staggered fixings are required, each row at
C04

Control joints
600mm centres and each fixing 25mm in from the flange. If the
Control joints may be required in the partition to relieve stresses
floor is uneven, a 38mm thick timber sole plate equal to the width
induced by expansion and contraction of the structure (refer to
of the channel should be used.
Partitions introduction C04. S01. P10 – construction detail 12). They
should coincide with movement joints within the surrounding
If the concrete or screeded floor is new, consideration should be
structure.
given to the installation of a damp-proof membrane between the
floor surface and the channel or sole plate.
Deflection heads

Splicing Partition head deflection designs may be necessary to


accommodate deflections in the supporting floor. Deflection heads
To extend studs, overlap by 600mm (minimum). Fix together using
may also be required to the underside of roof structures subjected
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two
to positive and negative pressures.
to each flange), or by using the Gyproc Stud Interlocking Tool twice
to each flange. Refer to Partitions introduction C04. S01. P11 – construction
details 15-22.
Refer to Partitions introduction C04. S01. P07 – construction
detail 1.
To minimise the loss of acoustic performance:

Partition to structural steelwork junctions Refer to C02. S01. P10 – Building acoustics.

When designing the layout of rooms requiring separation by sound


Services
insulating walls abutting structural steelwork, consideration should
be given to the potential loss of sound insulation performance Penetrations
through the steelwork. Penetrations of fire-resistant or sound-insulating constructions
for services need careful consideration to ensure that the
Refer to C02. S01. P10 – Building acoustics.
performance of the element is not downgraded. Consideration also
needs to be given to the services themselves so they do not act as
Door openings
the mechanism of fire spread or sound transmission.
The designer should consider thickness tolerances of the partition
Refer to C02. S01. P32 – Service installations.
types in relation to the proposed door frame detail. Standard door
frame detailing to suit BS 5234 Light and Medium Duty applications
is shown in Partitions introduction C04. S01. P13 – construction
detail 25. Detailing to satisfy BS 5234 requirements for Heavy and Handy hint
Severe Duty Rating is shown in Partitions introduction C04. S01. P14
– construction details 26 and 27. The door manufacturer should Where access is limited to one side of the
also be consulted in relation to door details. head, e.g. M+E cages already installed in
corridors
Specialist advice should be sought from door manufacturers and
Refer to C05. S02. P02 - ShaftWall.
Acoustic Consultants to ensure the required acoustic performance
is achieved. This becomes more important as acoustic requirements
increase.

C04. S02. P27 british-gypsum.com


GypWall classic
GypWall classic design (continued)

Electrical
The installation of electrical services should be carried out in
accordance with BS 7671. The cut-outs in the studs can be used Handy hint
for routing electrical and other small services (refer to Partitions
introduction C04. S01. P07 – construction detail 2). Switch boxes For alternative stud types and / or reduced
and socket outlets can be supported from Gypframe 99 FC 50 Fixing centres, to increase maximum partition
Channel fixed horizontally between studs, or a high performance height, further options are available.
socket box detail used where higher acoustic performance is Refer to C04. S01. P05, table 2.
required.

Where Gypframe AcouStuds are used, services are routed through


50mm x 28mm ‘H’ shaped push-outs, at the same centres as shown

Partitions
in Partitions introduction C04. S01. P07 – construction detail 2a
for conventional cut-outs. Cables should be protected by conduit,
SpecSure®
or other suitable precautions taken to prevent abrasion when they
All our systems are covered by SpecSure® when
pass through the metal frame. Service cut-outs should be aligned to
using genuine British Gypsum and Saint-Gobain
allow easy installation of service. If studs require cutting, cut from
Isover products.

C04
the same end of each stud to ensure cut-out alignment.

Independent support

When designing for the installation of services such as fire


dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the
damper - this will determine whether it can be supported directly
from the partition or needs to be independently supported from the
structure.

Refer to Partitions introduction C04. S01. P17 – construction


details 29-31.

Fixtures

Lightweight fixtures can be made directly to the partition linings.


Medium weight fixtures can be made to Gypframe 99 FC 50
Fixing Channel. Heavyweight fixtures (to BS 5234) such as wash
basins and wall cupboards, can be fixed using plywood secured by
Gypframe Service Support Plates.

Refer to C02. S01. P33 – Service installations.

Access for maintenance

Gyproc Profilex Access Panels are available to provide access for


maintenance. Access panels must be fully compatible with drywall
construction and match the fire rating of the partition.

Refer to profilex.co.uk for further information.

Board finishing

Refer to C08. S01. P03 – Finishes.

Tiling

Tiles up to 32kg/m2 can be applied to the surface of lightweight


partition systems.

Refer to C08. S04. P02 – Tiling.

Construction details

For standard GypWall construction details

Refer to Partitions introduction C04. S01. P07 – construction


details.

0115 945 6123 [email protected] C04. S02. P28


GypWall classic system components
GypWall classic

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (48 S 50, 70 S 50, 92 S 50, Gypframe Extra Deep Flange Floor & Ceiling
146 S 50) Channels (50 EDC 70, 72 EDC 80, 94 EDC 70,
Vertical stud providing acoustic and structural 148 EDC 80)
performances designed to receive fixing of board Floor and ceiling channels with extra deep flanges
to both sides. for retaining the Gypframe studs at floor and
ceiling junctions for partitions over 8000mm high.
Also used around openings and in deflection heads
(maximum 50mm deflection).
Partitions

Gypframe ‘I’ Studs (70 I 50, 92 I 90, 146 I 80, Gypframe 99 FC 50 Fixing Channel
146 TI 90) A versatile metal fixing channel used to support
Enhanced strength stud that allows for increased medium weight fixtures on walls.
partition height, designed to receive fixing of board.
C04

Gypframe AcouStud (70 AS 50, 92 AS 50, 146 AS 50) Gypframe GFS1 Fixing Strap
Vertical stud providing enhanced acoustic and Used to support horizontal board joints and within
structural performances designed to receive deflection heads.
fixing of board to both sides.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe GFT1 Fixing T
Channels (50 FEC 50, 72 FEC 50, 94 FEC 50, Used to support horizontal board joints.
148 FEC 50)
Standard floor and ceiling channels for retaining
the Gypframe studs at floor and ceiling junctions Gypframe GA6 Splayed Angle
and around openings to heights not exceeding Steel angle providing framing stability and
4200mm. board support.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe Service Support Plate
(50 DC 60, 72 DC 60, 94 DC 60, 148 DC 60) For installation of 18mm plywood within
Floor and ceiling channels with deep flanges for a partition cavity to support medium to
retaining the Gypframe studs at floor and ceiling heavyweight fixtures.
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Board products ( Refer to C10. S03. P02 for details)

Gyproc WallBoard Gyproc SoundBloc1


Standard gypsum plasterboard. Gypsum plasterboard with a high density core for
enhanced sound insulation performance.

Gyproc Moisture Resistant Gyproc SoundBloc f


Gypsum plasterboard with moisture resistant Gypsum plasterboard with fire resistant additives
additives in the core and special green lining paper and a high density core for enhanced sound
for easy recognition. insulation performance.

Gyproc FireLine1 Gyproc Plank


Gypsum plasterboard with fire resistant additives. Standard gypsum plasterboard located as an
inner layer.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S02. P29 british-gypsum.com


GypWall classic system components (continued)

GypWall classic
Board products ( Refer to C10. S03. P02 for details)

Glasroc H tilebacker3 Glasroc F firecase


Non-combustible glass-reinforced gypsum board Non-combustible glass-reinforced gypsum board.
with a water resistant pre-primed acrylic coating Used to form deflection head.
to receive tiling.

Glasroc F multiboard Gyproc CoreBoard


Non-combustible glass-reinforced gypsum board. Gypsum plasterboard with fire and moisture
Providing optimum acoustic and fire performance. resistant additives. Used to form deflection head.

Partitions
3
Glasroc H tilebacker is suitable for use in high moisture environments.

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Jack-Point Screws

C04
Corrosion resistant self-tapping steel screws For fixing boards to Gypframe metal framing
for fixing board to metal framing less than 0.8mm thick or greater (‘I’ studs 0.6mm thick
0.8mm thick ('I' studs less than 0.6mm thick). and greater).

British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing 0.8mm thick or
0.8mm thick ('I' studs less than 0.6mm thick). greater ('I' studs 0.6mm thick or greater).

British Gypsum Wafer Head Drywall Screws


Corrosion resistant self-tapping steel screws
for fixing metal to metal framing less than
0.8mm thick ('I' studs less than 0.6mm thick).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc FireStrip Gyproc Sealant


A soft extruded linear intumescent gap sealer Used to seal air paths for optimum sound
to maintain fire resistance located directly to insulation.
the underside of the soffit when forming a
deflection head.

Gyproc Control Joint Gyproc Joint Tape


To accommodate structural movement of up A paper tape designed for reinforcement of flat
to 7mm. joints or internal angles.

0115 945 6123 [email protected] C04. S02. P30


GypWall classic system components (continued)
GypWall classic

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
Partitions

common backgrounds including undercoat plasters


and plasterboard. For more information refer to
C02. S01. P49.
C04

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for reinforcement and finishing of board
joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200) Isover Modular Roll


Glass mineral wool for enhanced acoustic Glass mineral wool for enhanced acoustic
performance. performance.

Stone mineral wool (by others)


For fire-stopping.

Access panels ( Refer to profilex.co.uk for details)

Profilex Access Panel


Panel for access to cavity.

C04. S02. P31 british-gypsum.com


GypWall classic system installation overview

GypWall classic
Scan the image with this frame
for more information and
videos related to this system
This is intended to be a basic description of how the system is installed. Or visit gyp.sm/b/l2
For installation guidance refer to the British Gypsum Site Book.

Partitions
Appropriate Gypframe channels are suitably Gypframe 'C' Studs are suitably fixed to Gypframe studs are then friction fitted into
fixed to the floor and soffit. abutments. the Gypframe Floor & Ceiling Channels at
required centres.

C04
Door openings are constructed to suit the The perimeter of the partition is then sealed M&E services can be located within the
partitions' duty rating. on both sides with Gyproc Sealant. partition cavity.

Isover insulation can also be added to Gyproc plasterboards or Glasroc specialist


the partition cavity for increased acoustic boards are fixed to the Gypframe framework
performance. with British Gypsum Drywall Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 [email protected] C04. S02. P32