Pump Capacity Final
Pump Capacity Final
Pump Capacity Final
Using galvanized iron pipe: system through water pump shall be 13.81 m.
Roughness coefficient (e) is 0.15 mm
Computing for water pump power;
Using Colebrook equation:
𝑃 = 𝑄𝛾𝐻𝐴
𝜀
1 𝐷 2.51
= −2 log ( + )
√𝑓 3.7 𝑅𝑒√𝑓 𝑃 = (0.003)(9810)(13.81)
25.4
(5.92)( )(1000)
1000
Re =
1.307 𝑥10−3
Re = 76,666.41
0.15
1 2.51
= −2 log ( 38.1 + )
√𝑓 3.7 76,666.41√𝑓
𝑓= 0.02969
E1 = E2
𝑃1 𝑣12 𝑃2 𝑣22
+ + ℎ1 + 𝐻𝐴 = + + ℎ2 + ℎ𝑓
𝛾 2𝑔 𝛾 2𝑔
2.632
0 + 0 + 0 + 𝐻𝐴 = 0 + + 6.602 + ℎ𝑓
2(9.81)
𝐻𝐴 = 6.95 + ℎ𝑓
𝑓𝐿𝑣 2
Whereℎ𝑓 = ;
2𝑔𝐷
(0.02969)(24.984)(2.632 )
ℎ𝑓 =
(2)(9.81)(0.0381)
ℎ𝑓 = 6.86 m
Thus,
𝐻𝐴 = 6.95 + 6.86
𝐻𝐴 = 13.81 m