0% found this document useful (0 votes)
36 views1 page

Timber Plank Capacity

The document discusses the design of timber plank fencing for an irrigation tank including material properties, member sizing, design loading, and stress calculations showing the design is adequate with a safety factor of 4.98.

Uploaded by

ChangHangWing
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views1 page

Timber Plank Capacity

The document discusses the design of timber plank fencing for an irrigation tank including material properties, member sizing, design loading, and stress calculations showing the design is adequate with a safety factor of 4.98.

Uploaded by

ChangHangWing
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Project: Bedok North Road

Location: Timber Plank Fencing for Irrigation Tank


Design Element: Timber Plank

Figure:

Material Properties:
Timber Standard = ASTM C1185
Flexural Strength, f = 11 N/mm²
Modulus of Elasticity, E = 5000 N/mm²
Timber Density, γ = 12 N/mm³

Member Sizing:
Section Width, B = 150 mm
Section Thickness, t = 25 mm
Cross Section Area, A = 3750 mm²
Second Moment of Area, I = 195313 mm⁴

Design Loading:
*Assuming 1kN of human load acting at the centre of timber plank
Live Load, PLL = 1.00 kN
Factored Point Load, PULS = 1.50 kN [DL*1.5]
Design Span, L = 1.15 m
Design Bending Moment, MEd = 0.431 kN.m
Timber Bending Stress, σ = 2.208 N/mm² < f = 11N/mm2, OK!!
Factor of Safety, F = 4.98