IQAN-XA2 Uk Interlok
IQAN-XA2 Uk Interlok
IQAN-XA2 Uk Interlok
I/O Modules
Electronic Control Systems
Catalogue HY33-8385/UK Electronic Control Systems
Technical Information IQAN-XA2 I/O Modules
Application General
The IQAN-XA2 is an IQANdesign platform expansion Weight 0.75 Kg
module in the IQAN product group. This unit is designed Temperature range
for high digital I/O count, weather resistance, and Operating, ambient -40 to +70 °C
safety. Storage, ambient -40 to +100 °C
Protection outdoor use
All IQAN expansion modules communicate with a master Voltage supply 9 - 32 Vdc
over a CAN bus. The IQAN-XA2 module has increased Current consumption (idle) 95 mA (14 Vdc)
I/O flexibility that allows the user greater freedom in 75 mA (28 Vdc)
defining signals for measurement and control. Data interface Parker ICP
(IQAN CAN Protocol)
I/O flexibility
Outputs
Inputs Proportional outputs
The IQAN-XA2 module has eight voltage inputs for Type current mode current - closed-loop
connection of 0-5 Vdc signals. Four of the inputs are PWM mode voltage - open-loop
multi-purpose and for flexibility may be configured as Signal range 100 - 2000 mA
frequency inputs or as directional frequency (quadrature) Dither frequency 25 - 333 Hz
inputs for measuring speed and position. Resolution 1 mA
Digital outputs
Outputs Type high side switch
The XA2 module has six on-off outputs that are high- Max load 2A
side power outputs. Inputs
The XA2 module also has six double proportional Voltage inputs
outputs for controlling proportional valves. These Signal range 0 - 5 Vdc
outputs can control six bi-directional valve sections or Resolution 5 mV
six single solenoid devices (ie. proportional cartridge Frequency inputs
valves). The proportional outputs can be used in two Signal range (speed mode) 2 - 30000 Hz
(position mode) 0 - 30000 Hz
different modes. Either Current mode (current closed-
Quadrature inputs
loop) or PWM mode (voltage open-loop) signals can
Signal range (speed mode) 2 - 30000 Hz
be selected and the parameters configured using IQAN
(position mode) 0 - 30000 Hz
software.
Digital inputs
For flexibility these outputs may also be configured as Signal high 4 Vdc - VBAT
up to six on/off outputs and up to twelve on/off inputs. Signal low 0 - 1 Vdc
The proportional outputs, on-off outputs and on-off
inputs share pin positions. Ordering part number
IQAN-XA2 5010033
Weather resistance
The aluminum housing is designed to be rugged, but
light and has a sealed, automotive AMP/Tyco power
timer connector. The IQAN-XA2 has a membrane to
prevent condensation inside the housing. This controller
is designed for the outdoor environment.
Safety
The unit executes a self-test during start up and cyclic
operation. An internal watch dog checks for software
errors and will interrupt outputs if errors are detected.
The IQAN-XA2 is made using selected components
and conforms to strict international requirements.
Diagnostics: If an error is detected an LED on the top
of the controller flashes a sequence to indicate the
nature of the error.
2 Parker Hannifin
Electronic Controls Division
Mölnlycke, Sweden
Catalogue HY33-8385/UK Electronic Control Systems
Technical Information IQAN-XA2 I/O Modules
Environmental protection
EMI Climate environment
ISO 14982:1998, Radiated emission IEC 60529:2001, IP66 (dust, water)
EN 55025:2003, Conducted emission DIN 40050 Part 9:1993, IP6K9K (steam jet cleaning)
ISO 11452-2:1995, Radiated susceptibility IEC 60068-2-30:1985 Db, Damp heat cyclic
ISO 11452-4:2001, Conducted susceptibility IEC 60068-2-78:2001, Damp heat, steady state
ISO 7637-2:2004, Conducted transient on power IEC 60068-2-14:1984 Nb, Change of temperature
ISO 7637-3:1995, Conducted transient on signal
Chemical environment
ESD IEC 60068-2-52:1996 Kb, Salt mist
ISO 10605:2001, ESD
Mechanical environment
IEC 60068-2-64:1993 Fh, Random vibration
IEC 60068-2-29:1987 Eb, Bump
7 mm/M6(x2) 60
32
142
164
67
52
75
unit=mm
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze all
aspects of your application, including consequences of any failure, and review the information concerning the product or sys-
tem in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems,
the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are
subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
Please contact your Parker representation for a detailed ”Offer of Sale”.
3 Parker Hannifin
Electronic Controls Division
Mölnlycke, Sweden
Parker Worldwide
© 2004-2015 Parker Hannifin Corporation. All rights reserved. Catalogue HY33-8385/UK POD 12/2015
www.parker.com