H3 CR 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Solid-state Twin Timers

H3CR-F CSM_H3CR-F_DS_E_1_5

DIN 48 × 48-mm Twin Timers


• Wide power supply ranges of 100 to 240 VAC and 48 to
125 VDC respectively.
• ON- and OFF-times can be set independently and so
combinations of long ON- or OFF-time and short OFF- or ON-
time settings are possible.
• Sixteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h
depending on the model to be used.
• Models with a flicker ON start or flicker OFF start are available.
• Easy sequence checks through instantaneous outputs for a
zero set value at any time range.
• Length, when panel-mounted with a Socket, of 80 mm or less.
• 11-pin and 8-pin models are available.

Model Number Structure


■ Model Number Legend
H3CR - F @ @ - @ @
1 2 3 4 5

1. Classification 3. Twin Timer Mode 5. Supply Voltage


F: Twin timers None: Flicker OFF start 100-240AC: 100 to 240 VAC
2. Configuration N: Flicker ON start 24AC/DC: 24 VAC/VDC
None: 11-pin socket 4. Time Range 12DC: 12 VDC
8: 8-pin socket 48-125DC: 48 to 125 VDC
None: 0.05 s to 30 h models
300: 1.2 s to 300 h models

Ordering Information
■ List of Models
Operating Supply 0.05 s to 30 h models 1.2 s to 300 h models
modes voltage
11-pin models 8-pin models 11-pin models 8-pin models
Flicker OFF 100 to 240 VAC H3CR-F 100-240AC H3CR-F8 100-240AC H3CR-F-300 100-240AC H3CR-F8-300 100-240AC
start
24 VAC/DC H3CR-F 24AC/DC H3CR-F8 24AC/DC H3CR-F-300 24AC/DC H3CR-F8-300 24AC/DC
12 VDC H3CR-F 12DC H3CR-F8 12DC H3CR-F-300 12DC H3CR-F8-300 12DC
48 to 125 VDC H3CR-F 48-125DC H3CR-F8 48-125DC H3CR-F-300 48-125DC H3CR-F8-300 48-125DC
Flicker ON start 100 to 240 VAC H3CR-FN 100-240AC H3CR-F8N 100-240AC H3CR-FN-300 100-240AC H3CR-F8N-300 100-240AC
24 VAC/DC H3CR-FN 24AC/DC H3CR-F8N 24AC/DC H3CR-FN-300 24AC/DC H3CR-F8N-300 24AC/DC
12 VDC H3CR-FN 12DC H3CR-F8N 12DC H3CR-FN-300 12DC H3CR-F8N-300 12DC
48 to 125 VDC H3CR-FN 48-125DC H3CR-F8N 48-125DC H3CR-FN-300 48-125DC H3CR-F8N-300 48-125DC
Note: Specify both the model number and supply voltage when ordering.
Example: H3CR-F 100-240AC
Supply voltage

1
H3CR-F
■ Accessories (Order Separately)
Adapter, Protective Cover and Hold-down Clip
Name/specifications Models
Flush Mounting Adapter Y92F-30
Y92F-73 *1
Y92F-74 *1
Protective Cover Y92A-48B *2
Hold-down Clip For PF085A Socket Y92H-8
(Sold in sets of two) For PL08 and PL11 Sockets Y92H-7

Note: Refer to H3CR-A datasheet for details.


*1 The Y92F-48B Front Cover and the Y92P-48G@ Panel Cover cannot be used at the same time.
*2 The Y92F-48B Front Cover is made from hard plastic.
Remove the Front Cover to change the set value.
The Y92F-48B Front Cover and the Y92F-73/-74 Flush Mounting Adapter also cannot be used at the same time.

Sockets
Timer Round Sockets
Pin Connection Terminal Models
11-pin Front Connecting DIN track mounting P2CF-11
DIN track mounting P2CF-11-E
(Finger-safe type)
Back Connecting Screw terminal P3GA-11
Solder terminal PL11
Wrapping terminal PL11-Q
PCB terminal PLE11-0
8-pin Front Connecting DIN track mounting P2CF-08
DIN track mounting P2CF-08-E
(Finger-safe type)
DIN track mounting PF085A
Back Connecting Screw terminal P3G-08
Solder terminal PL08
Wrapping terminal PL08-Q
PCB terminal PLE08-0

Note: 1. The P2CF-@@-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals.
2. The P3GA-11 and P3G-08 Socket can be used together with the Y92A-48G Terminal Cover to implement finger protection.
3. For details, refer to Socket and DIN Track Products.

Terminal Cover
Application Model Remarks
For back connecting socket Y92A-48G For P3G-08 and P3GA-11

Note: For details, refer to Socket and DIN Track Products.

2
H3CR-F
Specifications
■ General
Item H3CR-F H3CR-F8 H3CR-FN H3CR-F8N
Operating mode Flicker OFF start Flicker ON start
Pin type 11-pin 8-pin 11-pin 8-pin
Operating/Reset method Time-limit operation/Time-limit reset or self-reset
Output type Relay output (DPDT)
Mounting method DIN track mounting, surface mounting, and flush mounting
Approved standards UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.

■ Time Ranges
0.05 s to 30 h Models
Time unit s (sec) ×10 s (10 sec) min (min) h (hrs)
Setting 1.2 0.05 to 1.2 1.2 to 12 0.12 to 1.2
3 0.3 to 3 3 to 30 0.3 to 3
12 1.2 to 12 12 to 120 1.2 to 12
30 3 to 30 30 to 300 3 to 30

Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.

1.2 s to 300 h Models


Time unit ×10 s (10 sec) ×10 min (10 min) h (hrs) ×10 h (10 hrs)
Setting 1.2 1.2 to 12 1.2 to 12 0.12 to 1.2 1.2 to 12
3 3 to 30 3 to 30 0.3 to 3 3 to 30
12 12 to 120 12 to 120 1.2 to 12 12 to 120
30 30 to 300 30 to 300 3 to 30 30 to 300

Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.

■ Ratings
Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC
Operating voltage range 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models
Power reset Minimum power-opening time: 0.1 s
Power consumption 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC
24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC
approx. 1 W at 24 VDC
48 to 125 VDC: approx. 1.5 W at 125 VDC
12 VDC: approx. 1 W at 12 VDC
Control outputs Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.

3
H3CR-F
■ Characteristics
Accuracy of operating ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s)
time
Setting error ±5% FS ±50 ms max.
Reset time 0.1 s max.
Reset voltage 10% max. of rated voltage
Influence of voltage ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s)
Influence of temperature ±1% FS max. (±1% FS ±10 ms max. in ranges of 1.2 and 3s)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC
voltage 1 kV for 12 VDC, 24 VAC/DC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to
125 VDC
1.5 kV for 12 VDC, 24 VAC/DC
Noise immunity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±400 V for 12 VDC
Static immunity Malfunction: 8 kV
Destruction: 15 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Shock resistance Destruction: 980 m/s2 three times each in six directions
Malfunction: 98 m/s2 three times each in six directions
Ambient temperature Operating: −10°C to 55°C (with no icing)
Storage: −25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3)
2 kV line to ground (level 3)
Case color Light Gray (Munsell 5Y7/1)
Degree of protection IP40 (panel surface)
Weight Approx. 100 g

Note: Refer to the Life-test Curve.

4
H3CR-F
■ Life-test Curve
10,000
Switching operations (x 103)

5,000

1,000
30 VDC L/R = 7 ms
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
500 and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
250 VAC/30 VDC both cases, a life of 100,000 operations can be expected.
(cosφ = 1)
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

100
250 VAC (cosφ = 0.4)

Load current (A)

Connections
■ Block Diagrams

ON indicator OFF indicator Zero setting


detection
circuit

Indicator
circuit
ROM RAM Clock
Output
circuit

AC (DC) input Power supply One-chip microcomputer Time range/unit


circuit selectors

■ I/O Functions
Inputs ---
Outputs Control output Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob.

■ Terminal Arrangement
H3CR-F8 H3CR-F
H3CR-F8N H3CR-FN
H3CR-F8-300 H3CR-F-300
H3CR-F8N-300 H3CR-FN-300

(+)(~)

Power supply Power supply

Note: Leave terminals 5, 6, and 7 open.


Do not use them as relay terminals.

5
H3CR-F
Operation
■ Timing Chart
tON: ON set time
tOFF: OFF set time

Operating mode Timing chart


Flicker OFF start 0.1 s min

ON
Power
②-⑩ OFF
tOFF tON tOFF tON tOFF tOFF
(② - ⑦)

ONindicator Lit
Not lit

OFF indicator Lit


Not lit

Output NO
① - ③、⑪ - ⑨ ON
(① - ③、⑥ - ⑧)OFF

Output NC
① - ④、⑪ - ⑨ ON
(① - ③、⑤ - ⑧)OFF

Flicker ON start 0.1 s min.


Power ON
②-⑩ OFF
(② - ⑦) tON tOFF tON tOFF tON tOFF
ONindicator
Lit
Not lit

OFF indicator
Lit
Not lit

Output NO
ON
① - ③、⑪ - ⑨
(① - ③、⑥ - ⑧)OFF

Output NC
① - ④、⑪ - ⑨ ON
(① - ③、⑤ - ⑧)OFF

Note: 1. The reset time requires a minimum of 0.1 s.


2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance
of the Timer.

Nomenclature
OFF indicator (green) OFF-time unit display window
Lit when the output is OFF.
OFF-time unit selector (select one from sec.
ON indicator (orange) 10 s, min., and hrs, or from 10 s, 10 min, hrs,
Lit when the output is ON. and 10 h)

Scale range display


windows ON-time setting knob (with orange pointer)
For ON-time setting

OFF-time setting knob (with green pointer)


For OFF-time setting
Time range selector (select one
from 1.2, 3, 12, and 30 at full ON-time unit display window
scale)
For both ON-time and OFF-time. ON-time unit selector (select one
from sec, 10 s, min, and hrs, or from
10 s, 10 min, hrs, and 10 h)

6
H3CR-F
Dimensions
Note: All units are in millimeters unless otherwise indicated.

H3CR-F 17.4 66.6


H3CR-FN 48 5.7 52.3 0.7
6
H3CR-F-300
H3CR-FN-300

48 37 dia. 44.8 × 44.8

14 dia.

R1.3
11 pins

H3CR-F8 17.4 66.6


48 5.7 52.3 0.7
H3CR-F8N 6
H3CR-F8-300
H3CR-F8N-300
48 37 dia. 44.8 × 44.8

14 dia.

R1.3
8 pins

Dimensions with Front Connecting Socket Dimensions with Back Connecting Socket
P2CF-08-@/P2CF-11-@ P3G-08/P3GA-11

81.5 81.5
17.4 17.4
80 75
H3CR-F H3CR-F8
H3CR-FN H3CR-F8N
103.2* 100.9 92.3* 90.0
H3CR-F H3CR-F8
H3CR-FN H3CR-F8N

P3GA-11 P3G-08
Y92F-30 Y92F-30
(When (When
2.3* 2.3* Y92A-48G Y92A-48G
P2CF-11 P2CF-08
P2CF-11-E P2CF-08-E mounted) mounted)
*These dimensions vary with the kind of DIN track (reference value).

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

7
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

 Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

2011.10
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.