The document provides design parameters and load calculations for a structural analysis model. It includes calculations for dead loads, live loads, wind loads, and gantry loads based on given structural dimensions and specifications.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
43 views4 pages
Load Calulation
The document provides design parameters and load calculations for a structural analysis model. It includes calculations for dead loads, live loads, wind loads, and gantry loads based on given structural dimensions and specifications.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4
DESIGN PARAMETERS :
Primary load cases for staad pro models:
Dead Load Calculation:- Assuming AC sheeting load = 200N/ m*m =.2Kn/m*m Here 1.56m Purlin interval So load on intermediate purlin = .2X1.56 = 3.12 kN/m End purlin load = 3.12/2 = 1.56 kN/m Side Sheeting load on columns Assuming Sheeting load = .2kN/m*m Self weight of runner for purlin =.450 kN/m*m
Total load = .2 + .45 = .65 kN/m*m
Load per column:
One end column = 6.6/2 =3.3X.650= 2.145 kN/m*m Other end column = 5.6/2 = 2.80X 0.650= 1.80 kN/m One end side setting column =12.2/2 +3.3 =9.4 X .650 =6.1 kN/ m*m Other end side setting column =5.6/2 +12.2/2 = 8.9X.650= 5.785 kN/m Intermediate column = 12.2X .650 = 7.93 kN/m*m
Gable Sheeting Load:
14.5/2 X 0.650 = 4.7125kN/m*m for end 14.5 X .650 = 9.425 kN/m*m for intermediate column of side gable Live Load := For intermediate purlin We assumed .725 kN/m*m So intermediate purlin load = .725X1.56 = 1.131kN/m
Wind load calculation:-
Industrial Shed Wind load calculation; For roof As per IS 875 part 3 Vb= basic wind speed of Howrah as per IS 875 part 3 = 50m/s Wind load F on a roof truss by static wind method and given by: F= ( Cpe –Cpi) X AX Pd Where Cpe&Cpi are force co-efficient for exterior and interior of the structure. Assuming the permeability of the structure (opening) between ( 5- 20 %) of the wall area. Cpi=(+-).5, (+-).2 External press are coefficient for say tooth roofs Multi span structure F= ( Cpe –Cpi) Pd= K1 k2 K3 Vb K1= Risk co-efficient =1.08 ( Asper IS 875 part 3 Important building Table 1) K2 = Terrain height, structure size factor K3 = Topoghraphy factor K2 = terrain category 4 Class of structure C K2 = 1.03 ( As per IS 875 part 3 Table 2) K3 = 1 Vz = K1 K2 K3 Vb = 1.08X 1.03X1.0X50 = 55.62 m/s Pd = 0.6Vz*Vz = .6x55.62X55.62 = 1856.15N/m*m Wind from wind ward (-Z) = 1856.15 N/m*m F = (Cpe-Cpi)XAXPd = (.6+.5)XAX1.86 =2.046 A ( 7.41, 3.70) Wind from Leeward = (-.7-.5) XAX1.86 = -2.232 A ( -3.48, -1.84)
Wind from (+Z)
Wind ward = ( -.5-.5) X A X 1.86 = -1.86 A ( -2.90, -1.45) Lee ward = ( -.6 -.5)XAX1.86 = - 2.046A (- 7.36, -3.68) Wind from (-X, +X) (-.8- .5) AX1.86 = -2.418 A (-3.77, -1.88) Here H = 15 m B = 29 m L = 97 m So H/B = 15/29 = .51 L/B = 97/29 = 3.34 Case 1: Table 4 IS 875 part 3 (+Z) , (- Z) Gable Side ( Front) (.7 + .5) X AX 1.86 = 2.232 A ( 32.364, 16.182) Opposite Gable Side (Rear) = (-.1-.5)X AX 1.86 = -1.116A ( -16.182,-8.09) Side face (-0.5-0.5)xAx1.80 = -1.8A (-22.692, -5.208) Side face (0.7+0.5)xAx1.80 =2.32 A (27.5, 6.25) Opposite (far) side (-0.25-0.5)xAx1.8 = -1.395A = -3.908(1st column) = -12.415(2nd column) = -17.019(intermediate column) = -4.6075(far side) Gable side (-0.6-0.5)xAx1.80 =-0.246A (-29.667, -14.833) Gantry load calculation:-
Crane capacity= 40T
Assumed value of wheel base= 4m C/C Self weight of crane girder excluding trolley= 40T Self weight of crab or trolley= 10T Impact 25% due to moment Maximum moment due to surge= 5T
Load on single wheel due to self weight= 10T
Load on single wheel due to crane with trolley load= 20T Self weight of crab on single wheel= 5T Total load on single wheel= 35T With impact load on single wheel= 1.25x35= 44T