OPERATING AND INSTALLATION MANUAL
SOFTWARE
ISOCON INTERFACE
Release number: ISOCON_EN_IS_REV01
OPERATING AND INSTALLATION MANUAL
CONTENTS
INTRODUCTION ___________________________________________________________________________ 3
SOFTWARE TOOLS END USER LICENSE AGREEMENT _______________________________________________ 4
INSTALLATION ____________________________________________________________________________ 4
CONNECTING ISOCON AND PC________________________________________________________________ 5
PROGRAMMING THE CONVERTER USING ISOCON _________________________________________________ 6
CONNECTION DETAILS______________________________________________________________________ 7
WINDOW SECTIONS________________________________________________________________________ 8
ISOCON SYNTAX COMMANDS, READ, SET AND HELP _______________________________________________ 9
CONFIGURATION FILE COMMANDS ___________________________________________________________ 10
ISOCON UPDATE _________________________________________________________________________ 12
ERROR CODES ___________________________________________________________________________ 13
ADDRESSES _____________________________________________________________________________ 14
Page 2 of 14
OPERATING AND INSTALLATION MANUAL
INTRODUCTION
ISOCON is a real-time interface designated to interface any converter of Millennium series to PC, notebook or other compatible IBM ®
The most important functionalities of ISOCON Interface are:
Set, read and execute all functions by an alfanumeric string (ETP COMMAND).
Simulation of instrument display
Instrument data loggers downloading
Visualization of data downloaded from data loggers
The physical connection between PC and converters is done by IF2 cable, read the corresponding manual for details
Each instrument is configurable in two ways:
through the converter keypad (see converter operative manual)
through the ISOCON interface
ISOCON
CONVERTER NOTE
INTERFACE
SETTING BY
NOT
ALFANUMERIC POSSIBLE
Might be too difficult to insert data by the converter keypad
STRING
SETTING ALL NOT All functions are not available to the converter display (the available
FUNCTIONS POSSIBLE functions on display depend on converter model)
SHOW ETP
ONLY
COMMAND AND
DISPLAY DISPLAY
FUNCTIONS
FUNCTIONS
Page 3 of 14
OPERATING AND INSTALLATION MANUAL
SOFTWARE TOOLS END USER LICENSE AGREEMENT
Please read the following terms and conditions carefully before accepting to install and use this software. Unless you have a different license
agreement supplied software indicates your acceptance of this license agreement and warranty.
Registered Version
One registered copy of supplied software may either be used by a single person who uses the software personally on one or more computers, or
installed on a single computer used non-simultaneously by multiple people, but not both.
You may access to software through a network, provided that you have obtained and agreed to individual licenses for the software covering all
computers that will access the software through the network regardless if they access the software program concurrently or at different times.
Governing Law
This agreement shall be governed by Italian Law
Disclaimer of Warranty
THIS SOFTWARE AND ANY ACCOMPANYING FILES ARE GIVEN FREE OF CHARGE “AS IS” AND WITHOUT WARRANTIES AS TO PERFORMANCE
OR MERCHANTABILITY. THIS INCLUDES ANY OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED.
Because of the many hardware and software environments may be installed and used, NO WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE IS OFFERED.
Good data processing procedure dictates that any program be thoroughly tested with non-critical data before relying on the program. The user
must assume the entire risk of using the program. ANY LIABILITY OF THE SELLER WILL BE LIMITED EXCLUSIVELY TO PRODUCT REPLACEMENT.
INSTALLATION
Requirements
P.C. with Intel® i486® o Pentium® processor
Microsoft Windows 2000®, Windows Xp® and Windows Vista® operating systems WINDOWS 7®.
32MB RAM
Hard disk with at least 10MB of available space
CD-Rom unit
USB socket
Installation
The file of the ISOCON program has to be installed from the CD-ROM. It is necessary to install first the component on the hard disk and perform
the program from this unit.
If on the system a previous version of the software is present, it is recommended to uninstall it before install the new
version.
To install the application:
Close all the applications in use
Insert the CD in the CD-ROM unit
In the dialog box for the installation clicks on “Yes” to pass to the following window and accept the license, (if the installation not starts
automatically launch the only file .exe in the CD).
To continue, click “Next”.
Accept the license agreement and after click “Next”.
To change the file destination folder clicks on “Change…”, specify the desired folder and clicks on “Next”.
Click on “Install” to confirm the installation of summarizing window and proceed with the installation. At the end, a message will point
out that the software has been installed.
Select “Finish”.
To launch the application click on the desktop icon symbol.
Page 4 of 14
OPERATING AND INSTALLATION MANUAL
CONNECTING ISOCON AND PC
Morsettiera M1 Morsettiera M2
1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26
11 12 13 14 15 16 17 18 19 20 27 28 29 30 31 32
Mors. M3
Allen key spanner 8mm PG9 cork Programming gate
ISOCON
ENGLISH
SER.# 55J0015 AND
ITALIAN
USB COMMUNICATION
SOFTWARE
Page 5 of 14
OPERATING AND INSTALLATION MANUAL
PROGRAMMING THE CONVERTER USING ISOCON
ISOCON
ISOCON is a software interface that allows to send commands to the converter via
EN GLISH
SE R. # 55J0015 AND
ITALIAN
USB COMMUNICATION
USB pc port
SOFTWARE
CONVERTER
Converter model and
firmware version
Serial number
Converter display
Full list commands
Access code set
Selected commands appear here
Input windows, to read, execute
or set the command value
BUTTON AVAILABLE BUTTON AVAILABLE ON BUTTON MEANING
ON PC KEYBOARD CONVERTER KEYPAD
SHOW/HIDE CONVERTER DISPLAY
SHOW/HIDE CONSOLE COMMANDS
LONG PUSH
REFRESH TREEVIEW TOOLTIPS
SHOW/HIDE COM PORT AND CONNECTION DETAILS
LONG PUSH SEND PC DATA AND TIME TO THE CONVERTER
LONG PUSH SET CUSTOM LEVEL CODE
The icon appears at the top left of the converter display while a pc keyboard button is pushed. When the converter display is hidden appears
the icon symbol , (near the clock) every 10 seconds to indicate the converter communication.
Note: after the language change is recommended to click on the icon symbol refresh TreeView ToolTips to update the Console
commands.
Page 6 of 14
OPERATING AND INSTALLATION MANUAL
CONNECTION DETAILS
Connections details are shown clicking on the icon symbol . Connections details permit to set the RS 232 connection port, it is necessary if
the connection is done in auxiliary module presence. It is also selectable the COM port where make the connection, its speed and after open the
connection in manual mode or use a device autosearch.
This section allows to show (and modify) some important details regarding the connection to the converter:
Connector type used
Connection port
Connection speed
Address of the device that receives the commands
Address of the device that sends the commands
Converter search mode auto or manual
About the converter connection cable, ISOCON is set with “USB IF2 Cable only”; if the customer does not use the IF2 cable, he has to deselect
this flag.
Possible settings of RS 232 port connector type used are:
jack conn. when the physical connection between PC and converter is made by IF2 cable connected to the board female jack
connector
modulo aux. when are used TX and RX signal of a standard RS232 serial cable connected to the terminals of an auxiliary COM port
of the converter.
After selecting the RS 232 port it is possible to establish a connection in the following ways:
manual mode, selecting the communication port and its (only for RS 232 – modulo aux.) speed, the Manual key establishes the
connection
automatic connection search, pressing the Autosearch key to start it (without setting communication port and speed).
Supported ports from COM1 to COM32.
Page 7 of 14
OPERATING AND INSTALLATION MANUAL
WINDOW SECTIONS
RESIZE
It is possible to resize the dimension of every window section moving the double arrow cursor . All resizing is memorized for successive
software opening/closing (except the fourth here in the bottom right which does not memorized any movement).
Double arrow cursor
SET CODE LEVEL
It is equivalent to the ETP command ACODE and allows to insert the level code (2 or upper) to modify:
these level commands
configuration and function list files
CONSOLE COMMANDS
In this section are listed all the commands available. Positioning the mouse pointer over the command a mnemonic’s description will appear as
show below.
Menu grouped commands
Commands in alphabetical order
Change menu tree view mode
Clear test result
List Command selection: click on the ‘+’ symbol at the side of the each function menu to see the related functions and commands.
Converter commands window: shows the corresponding result of a command sent (the Clear text results key allows to clear this window).
Input window: this window allow to type the functions; read (command “?”), modify (command “=”) or get the range (command “=?”), for
which see next page.
Page 8 of 14
OPERATING AND INSTALLATION MANUAL
ISOCON SYNTAX COMMANDS, READ, SET AND HELP
The ISOCON software is tree structure, all functions are grouped in menu; placing the pointer over every function is visible the extended function
description.
It allows three actions (commands) for each function, which are:
[command] ? : READ the current value of function or function status
[command] =? : HELP COMMAND: show the function allowed range
[command] = : SET COMMAND: set the value/status
EXAMPLE: how to set the function GPAPN (ACCESS POINT NAME, given by internet provider for GPRS network)
SET COMMAND HELP COMMAND READ COMMAND
Select the command Select the command from Select the command from
from the list the list then press enter the list then press enter
The ETP software shows
Type in the settings, The ETP software shows the
the allowed field for the
then press enter current value of the function
specific command
In the HELP and the READ commands above, after seeing the result
of the initial request, you can SET a new value for the command by
ETP acknowledges the typing the command in the input window followed by ‘=’ and the
command with 0:OK new setting, then press enter.
If any value/status setting is not possible appears the message 5:ACCESS ERR. See page 13 for error codes list and meaning.
Page 9 of 14
OPERATING AND INSTALLATION MANUAL
CONFIGURATION FILE COMMANDS
The most interesting applications of ISOCON Interface are:
the capability to create a “Master configuration file” to speed up the configuration process of similar meters
to keep data stored for future board replacement.
Save configuration
It allows to save the Configuration List (on the PC).
Flag the Show file option to see the file’s content
The system suggests a file name, you could let as it is or change with a more appropriate/useful name. The file is saved on the path
showed on screen highlighted in azure. In case of needed, you could change it by the Change File Folder function; you could also
check the folder’s content by the View File Folder function.
By the Save configuration key of the ISOCON Interface you can save its configuration in a file, flag the Show file option to see and
modify the file’s content
The system suggests a file name, you could let as it is or change with a more appropriate/useful name. The file is saved on the path
showed on screen highlighted in azure. In case of needed, you could change it by the Change File Folder function; you could also
check the folder’s content by the View File Folder function
Edit this file removing only the data specific of this converter, e.g. the data regarding the connected sensor, and leaving unchanged the
other parameters specific of the application like measure unit, volume value of every impulse, alarms. At the end save the modified file
Now you can upload this file on other meters of the same application thus saving the time necessary to program again the parameters
that are the same on every meter
Finally you can program the parameters specific of every converter using ISOCON.
Example of Save configuration
1. Download the configuration
2. Remove the specific parameter of the converter and save the configuration file
Page 10 of 14
OPERATING AND INSTALLATION MANUAL
3. Upload the “Master Configuration” and set the specific parameters of the other converters.
Save function list
Isocon allows to customize the functions visible on the display; this function is RESERVED to FACTORY/SERVICE
SD CARD FILE COMMANDS or DATA LOGGER
See the converter manual, functions description section.
Page 11 of 14
OPERATING AND INSTALLATION MANUAL
ISOCON UPDATE
ISOCON Interface is able to check if new versions of its modules are available on manufacturer’s web site.
At the top there are a dropdown menu that allows to configure ISOCON updating.
This operation can be:
manually started by clicking the line “Check for new version of the program” in “Update Program” section
automatically started at every program start checking the option “Check for new version at every start of the program”. If
updates are available, click on the red lighted menu and confirm the pop-up, the requested updating process will start.
Page 12 of 14
OPERATING AND INSTALLATION MANUAL
ERROR CODES
CODE MEANING
0:OK The command is executed correctly
1:CMD ERR The command is not executable (not allowed/out of context)
2:PARAM ERR The parameter is out of range / not valid
3:EXEC ERR The command returned an error condition due to hardware/configuration problem
4:RANGE ADJ The command caused an internal automatic re-adjustment of the parameters
5:ACCESS ERR The command requires an access level greater than the current one set
6:BUFFER FULL The input or output buffer used for the communication is full
7:FILE NOTFND The requested file was not found on the SD memory
8:SDC ERR The SD memory is not readable/writable/present
9:BUSY The ETP interpreter is busy (executing another command in another task/channel)
Page 13 of 14
OPERATING AND INSTALLATION MANUAL
ADDRESSES
Isoil Industria spa
Head office
20092 Cinisello Balsamo (MI) Italy
27, via F.lli Gracchi
Phone +39-02-66027.1
Fax +39-02-6123202
E-mail:
[email protected]Web: www.isoil.com
Service
Isoil Industria spa
20092 Cinisello Balsamo (MI) Italy
27, via F.lli Gracchi
Phone +39-02-66027.1
Fax +39-02-6123202
E-mail: [email protected]
Page 14 of 14