P24LabExam Answers PDF
P24LabExam Answers PDF
Instructions: Work individually to complete each exercise to the best of your ability, show all your work, and
clearly explain your answers in the spaces provided or on the back of these papers.
Be sure to record all measurements (in SI units) and show all calculations. For items that require a numerical
result, write your answer as you would for a formal lab report, including a meaningful label to identify a value.
Your answer will be graded based on the accuracy of your result and proper reporting of uncertainty,
significant figures, and units.
Once the lab exam begins, you are not permitted to receive any assistance from your TA or other students.
However, you may use your lab manual, graded lab reports, notes, and textbook as resources for this exam. The
questions may be answered in any order, so adjust your work according to the availability of the lab equipment.
1. A simple pendulum is known to have a period of oscillation T = 1.55 s. Student A uses a digital stopwatch to
measure the total time for 5 oscillations and calculates an average period T = 1.25 s. Student B uses an analog
wristwatch and the same procedure to calculate an average period for the 5 oscillations and finds T = 1.6 s.
c) What is the most likely source of error that could account for the difference in the results?
Although the difference in period measurements is only 0.3 s, the original timing measurements must
have differed by 5 times this amount since we are told that the average period was calculated from the
total time for 5 oscillations. So even though reaction time (typically ~0.2 s) is a likely source of error,
this would not explain the discrepancy of approximately 1.5 s, or about one period. Therefore, the most
likely source of error is that Student A mistakenly measured only 4 oscillations instead of 5.
This example shows that a more precise measurement is not always more accurate.
2. The number of significant figures reported for a measured value suggests a certain degree of precision.
What is the relative uncertainty implied by the following numbers?
a) 0.30 implies an uncertainty of ± 3 % (possibly 2% from rounding error)
b) 9.8 implies an uncertainty of ± 1 % (possibly 0.5% from rounding error)
c) 52 implies an uncertainty of ± 2 % (possibly 1% from rounding error)
d) 0.503 implies an uncertainty of ± 0.2 % (possibly 0.1% from rounding error)
3. A student uses a protractor to measure an angle to be θ = 85° ± 1°. What should she report for sinθ ?
R = 0.767 ± 0.003 cm (half the diameter measured with Vernier calipers: D = 1.534 ± 0.005 cm)
7. Use any available equipment to measure the acceleration of a glider on an inclined air track as accurately as
possible. Clearly identify the measurements you make and the procedure you use.
A number of different procedures could be used to find the acceleration. The simplest is to release the
glider from rest and use a stopwatch or photogate to measure the average time t for it to travel a
distance x and use the constant acceleration equation: x = 0.5at 2
x = 1.500 ± 0.005 m, t(s) = 1.12, 1.06, 1.19, 1.15, 1.08 so, <t> = 1.12 s with SE = 0.02 s
8. A group of students are told to use a meter stick to find the length of a hallway. They take 6 independent
measurements as follows: 3.314 m, 3.225 m, 3.332 m, 3.875 m, 3.374 m, 3.285 m. Show how they
should report their findings and explain your answer.
The measurement of 3.875 m is an extreme outlier (it is 10 standard deviations from the other values)
and is most likely a mistake. The best estimate of the length is found from the average of the other 5
values (3.31 m), which agrees with the median value of all 6 data points (3.32 m) within the uncertainty
determined as the standard error of the 5 “good” data values.
9. In an investigation to empirically determine the value of π, a student measures the circumference and
diameter of several circles of varying size and uses Excel to make a linear plot of circumference versus diameter
(both in units of meters). A linear regression fit yields the result of: y = 3.1527x – 0.0502, with
R2 = 0.9967 for the 5 data points plotted. How should this student report the final result? Does the empirical
ratio of C/D agree with the accepted value of π?
C/D = 3.15 ± 0.10 (where the uncertainty is the standard error in the slope)
Yes, this empirical value agrees with π since 3.1416 lies within the experimental uncertainty range.
10. A student performs a simple experiment to find the average acceleration of a falling object. He drops a
baseball from a building and uses a string and meter stick to measure the height the ball was dropped. He uses a
stopwatch to find an average time of fall for 3 trials from the same height and reports the following data: h =
5.25 ± 0.15 m, t = 1.14 ± 0.06 s.
a) Use the equation a = 2h/t2 to determine the average acceleration and its uncertainty.
2 h 2( 5.25 ± 0.15 m )
a= = = 8.1 ± 0.9 m/s 2
t 2
(1.14 ± 0.06 s ) 2
Explanation: By applying the propagation of uncertainty equation, we find that the relative uncertainty
for the height is ± 2.9% and for the time is ± 2(5.3%), so that the combined relative uncertainty (adding
in quadrature) is ± 10.9%. This yields an average acceleration of
8.08 ± 0.88 m/s2 , which when properly rounded is 8.1 ± 0.9 m/s2 .
b) Comment on the accuracy of the acceleration result. Do you think the student made any mistakes?
While it is impossible to know if the student's result is accurate without knowing detailed information
about the drag factor, it is plausible that the average acceleration of the falling ball is about 0.8 g over
the fall distance of about 3 stories. Since the objective of the experiment was to find the average
acceleration of a falling object (as opposed to measuring g), the systematic effect of the air resistance is
not an error, and just because the average acceleration is significantly less than g does not necessarily
indicate that a procedural mistake was made by the student. However, if the acceleration value was
significantly greater than g, then we could claim that the student made a mistake.
c) What one suggestion would you tell this student to improve the experimental result? Please explain.
The uncertainty in the time measurement contributes the most to the overall uncertainty in the average
acceleration (by a factor of about 3 times the height measurement), so improving the precision of this
measurement (with more trials or an automated timing device) will most significantly reduce the
uncertainty of the result, and hopefully give a more accurate value.
11. Describe a procedure you could use to determine the coefficient of friction between various materials.
The coefficient of kinetic friction between two objects (like a wooden block and a table) could be
determined by using a spring scale or force probe to measure the force required to pull the object
across a horizontal surface at constant speed so that the tension equals the frictional force. Then the
coefficient of friction can be calculated by dividing the frictional force by the normal force, which in this
case is equal to the magnitude of the object’s weight. The coefficient of static friction is determined in a
similar fashion from the maximum tension force that is needed to initially get the object moving.
An alternative method is to place the object on an inclined plane and increase the angle made with the
horizontal until the object first starts to slide (for static friction) or the slightly lower angle at which the
object slides with constant speed (for kinetic friction). The coefficient of friction can then be calculated
from these two angles by the simple equation: µ = tan θ