0% found this document useful (0 votes)
107 views2 pages

TPItL10 CtLv10 Com EN

The programmable safety converter is designed to fulfill safety integrity level 2 (SIL 2) requirements according to standard EN61508. It has universal power supply and input capabilities, a programmable isolated analog output, and optional relay outputs. The device can be easily configured via a front panel micro-console or PC software for applications requiring functional safety.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views2 pages

TPItL10 CtLv10 Com EN

The programmable safety converter is designed to fulfill safety integrity level 2 (SIL 2) requirements according to standard EN61508. It has universal power supply and input capabilities, a programmable isolated analog output, and optional relay outputs. The device can be easily configured via a front panel micro-console or PC software for applications requiring functional safety.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PROGRAMMABLE SAFETY CONVERTER

TPI t L 10 / µCtL10 ARDETEM SFERE


Designed according to the standard EN61508 in order to fulfill the requirements of a safety integrity level (SIL 2).

2
L
)

S I nd
ard EN
615
08

( Sta

Relay outputs (option R): 2 change-over


relays (5A/250 VAC on resistive load).
Features Isolation: input / outputs / supply.
• Universal power supply: • Safety:
20 to 270 Vac and 20 to 300 Vdc Checking of the current on the output loop
• Universal input: Self-diagnosis
Sensor rupture detection (according to input)
100mV, 1V, 10V, 300V, 20mA, Pt100 3 wire, Ni 100, Checking of the configuration data
thermocouple, resistance and potentiometer. Programming protected by code
Typical response time: 500 ms
• Test functions:
• Supply for 2-wire sensor - Simulation of the input measure
• 1 isolated analog output (A) programmable in 0-4-20mA - Simulation of the analog output
(active/passive) current or in 0-10V voltage. - Test for setting in safety position

Configuration Dimensions
Numbering of the 22.7(*)
130.4
Easy programming on front face with a micro-console or with the terminals:
PC software SuperVISION (ARDETEM) or MCvision (SFERE) connectors A/B/C 1234
119.9
Voltage presence Led
Programming with the Micro-console ON (green) or major error
indication (red)
This minaturised micro-console connected on the front face of the A B C
instruments allows: Relay 1 Location of the upper connectors
- the visualisation of the measure and the status of the analog and Relay 2
relay outputs,
- the visualisation and the modification of the programming,

µconsole
108.5

(protection by code) µconsole plug


- the teleloading of programming files for duplication to other
converters. PC connection plug
Programming by PC: SuperVISION/MCvision Location of the lower connectors
Programming software (Windows environment) allowing: D E F
- the storage of configurations as files which can be consulted, Numbering of the
modified, duplicated or loaded into the converters, terminals:
1234
- the edition and printing of files with or without having a converter connectors D/E/F
connected. (*) 26.5 with µconsole

Dimensions
Self-extinguishing case of black UL 94VO ABS. Coding
Mounting in switchbox: latching on symmetrical DIN rail.
Rack version: consult.
Plug-off connectors for screwed connectings Types:
Dimensions: 22.5x75x120 mm ARDETEM reference: TPItL10
with µconsole: 26.5x80x130 mm SFERE reference: µCtL10
To allow the inserting of the µconsole: mount Type TPI/µC tL10 AR
the instruments vertically (horizontal DIN rail)
leaving a 5mm space between each.
Operating T°: -5° to 50°C Outputs:
Storage T°: -20 to 70°C A analog I/U isolated
R 2 change-over relays
22.7 5 22.7 3 26.5 1 Power supply:
♦ according to the directive EMC 2004/108/CE.. 20 to 270 VAC and 20 to 300 Vdc
Compliance with standards:
Power draw : 3.5 W max. 6 VA max.
IEC 61000-6-4 on emissions, IEC 61000-6-2 immunity Dielectric withstanding : 2 kV-50Hz-1min.
(industrial environment)
Order example: For a converter with universal input + analog output +
IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-6 (level 3)
2 relays, request the reference TPItL10/µCtL10 AR
Sensitiveness < ±1% of the measure range

695 1 0 S O U C I E U E N J A R R E S T - Tél. : 33(0)4 72 31 31 30 Fax. : 33(0)4 72 31 31 31 CA CO2016/31


Features Connectings
Inputs Upper connectors

Types of Measure range adjus- Permanent Intrinsic Console Input


Supply Inputs
INPUTS table from: overload error resolution impedance
mA∗ -2 to +22mA ±100mA 10 µA Max. drop A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4
0.9V
mV∗ -10 to +110mV ±1V 100 µV
+ 300V -
< ±0.1% of
- 0.1 to +1.1V ±50V the MR 1 mV
+ - 1V/10V
≥ 1MΩ AC ~ ~
V -1 to +11V 10 mV DC + - + - mV/mA
-30 to +330V ±600V 100 mV
Thermocouples∗ °C °F + - Tc
Standard IEC 581
J -160/1200 -256/2192
K -270/1370 -454/2498 - (2) Resistance
B 200/1820 392/3308 <±0.1%
R < 440Ω
R -50/1770 -58/3218 of the MR 0.1° or 1° ≥ 1 MΩ
S -50/1770 -58/3218 C or F R<2.2KΩ or 8.8KΩ
T -270/410 -454/770 (optional)
E -120/1000 -184/1832
N 0/1300 -32/2372
L -150/910 -238/1670 PT100 3 wire
W 1000/2300 1832/4172
W3 0/2480 32/4496 potentiometer
WRE5 0/2300 32/4172

Sensor Pt100Ω (1)∗ °C °F -


+ - 2-wire
3 wire, Stand.IEC
-200/850 -328/1562 -
<±0.1% 0.1° or 1° Current transmitter
751 (DIN 43760) of the MR C or F 250µA
Sensor Ni 100 3 -60/260 -76/500 -
wire (1)∗
Resistive sensors Calibers 0-440 Ω ∗ - <±0.1% of the 0,1Ω Current Lower connector
and 0-2.2 kΩ MR (0.5% for (400Ω) max.
(0-8.8 kΩ optional) 0-2 kΩ) 1Ω (2kΩ) 250µA Outputs
Potentiometer from 100Ω to 10 kΩ - Voltage Analog output Relay outputs
0,1% max.
100mV
D1 D2 D3 D4 E1 E2 E3 E4 F1 F2 F3 F4
Supply for 2-wire 24 VDC ±15% with protection from short-circuits.
sensor 25 mA max.
ON2 ON1
Special linearisation
programming
On inputs: mV, V, mA.
resistive sensors and potentiometer
- + - +
V mA
up to 20 points
0-10V 0-4/20mA OFF2 C2 OFF1 C1
Square root extraction On inputs mV, V or mA
active
Relay 2 Relay 1

CA CO2016/31 - A 12/16 - Any data in this documentation may be modified without prior notice.
MR Measure range Thermal drift <150ppm /°C

(1) Line resistance <25Ω ∗ Sensor break detection:


Lr !
Input mA (if down scale ≥
(2) Or 30 µV typical (60µV Max.) 3.5mA) Only 1 of the 2 analog outputs
CJC efficiency: 0.03°C/°C from Other inputs: a 12µA pulsed current can be activated at the same
-5 to 50°C allows the detection of line or 0-4/20mA passive time (outputs not indepedent).
sensor break. external source 30V max.

Outputs
Features related to the
Code
Types of
Features
safety
OUTPUTS
Current
active/ Current: Direct or reversed 0-4-20mA
A 1 analog Load impedance ≤ Lr 600Ω
passive Type of the instrument B
Voltage: Direct or reversed 0-10V
Voltage Load impedance ≥ Lr 5000Ω SIL (safety integrity level) 2

2 setpoints per relay, configurable on HFT (hardware fault tolerance) 0


the whole MR. Hysteresis programma-
R
2 change-over relays ble from 0 to 100%. Time delay pro- PFH (probability of failure per hour) 5E10 -8 /h
grammable from 0 to 25 sec. (250 VAC
5A or 30VDC 2A on resistive load) PFD (probability of failure on demand) 2,2E10 -4
For a Tproof of 1 year

Typical response time: 500 ms (for a variation from 0 to 90 % of SFF (safe failure fraction) 93%
the input signal)
Add 50 ms for the response time on the analog output
Only the output 4-20mA and the relays can be used in a safety
system.
Galvanic partition:
2kV-50Hz-1min. between supply, input, analog output, relay
outputs

y o u r r e p r e s e n t a t i ve

Route de Brindas
Parc d’activité d’Arbora N°2
69510 SOUCIEU EN JARREST
- FRANCE -
e-mail : [email protected] Tél. : 33 (0)4 72 31 31 30
http : //www.ardetem.com Fax. : 33 (0)4 72 31 31 31

You might also like