Assignment RAC
Assignment RAC
1. Explain the effect of evaporator pressure, condenser pressure and liquid sub-
cooling on performance of vapor compressor refrigeration system using P-h
diagram.
2 Explain standard vapor compression refrigeration cycle with T-s and P-h
diagram. What is the effect of sub-cooling on the performance of vapor
compression refrigeration system?
3 Define refrigeration, State the Name of different types of system used for
cooling of aircraft cabin. Also explain with schematic diagram Bootstrap air
Refrigeration system.
7 An air refrigerator working on Bell Coleman cycle takes in air at 1 bar and at
a temperature of 10 0C. The air is compressed to 5 bar abs. The same is
cooled to 25 0C in the cooler before expanding in the expansion cylinder to
cold chamber pressure of 1 bar. The compression and expansion laws
followed are pv1.35 = C and pv1.3 = C respectively. Determine COP of the
plant and net refrigeration effect per kg of air. Take Cp = 1.009 kJ/kg K and
R = 0.287 kJ/kg K for air.
6 With neat sketch explain working of steam jet refrigeration system and list
its advantages and disadvantages.
b) specific humidity
c) Relative humidity
d) Thermodynamic wet bulb temperature
f) Degree of saturation
g) Humidity ratio
j) By-pass factor
4 The pressure and temperature of mixture of dry air and water vapor are
736mm of Hg and 210 C. The dew point temperature of the mixture is 150 C.
Determine the following using steam table:
5 A room has sensible heat gain of 24 kW and latent heat gain of 5.2 kW and it
has to be maintained at 26 ⁰C DBT and 50% RH. If 180m3/min of air is
supplied to the room, calculate the supply air condition.
1. State and explain various heat loads to be considered for cooling load
calculation of typical building.
ADP temperature = 10 0C
If the quantity of re-circulated air is mixed with the conditioned air after the
cooling coil, find the following:
(i) Condition of air leaving the conditioner coil and before mixing with the
re-circulated air
(ii) Condition of air before entering the hall
(iii) Mass of air entering the cooler
(iv) Mass of total air passing through the hall
(v) BF of the cooling coil
(vi) Refrigeration load on cooling coil in TR
4 The pressure and temperature of mixture of dry air and water vapor are
736mm of Hg and 210 C. The dew point temperature of the mixture is 150 C.
Determine the following using steam table:
5 What are the different types of insulating material used for air conditioned
building? What factors are considered in the selection of insulating
materials?
6 What is the importance of relative humidity for the selection of insulation?