DS P5500-P6500-Low-press-gauge PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Data Sheet

P5500 and P6500 Low Pressure


Diaphragm Gauges
FEATURES
n “Dry cell” mechanism
n Ranges from 10 Inches of Water
n Overpressure protection up to 10 times range (OPT.)
n Available dry or liquid filled
n Optional ATEX certification
n Threaded or flanged process connections

TYPICAL USES
n Oil & gas
n Chemical and petrochemical
n Food and beverage
n Vacuum pumps
n Pulp and paper
Threaded
Flanged

SPECIFICATIONS
(optional)
Accuracy: ±1.6% of span
Size: 100mm, 160mm
Range: 10 IW to 300 psi including vacuum ranges KEY BENEFITS
Process Conn. Location: Lower, threaded or flanged • Uses a “dry cell” mechanism with no system fill
Process Conn. Size: fluid to avoid possible media contamination
Threaded: ¼ NPT Male, ½ NPT Male
Flanged: ½˝, 1˝, 2˝, and 3˝ • IP66 for use outdoors or humid environments
P5500: Open front with pressure relief disc and • 10X full scale range over pressure capability
Case Style:
ventable fill plug on top (XHP Option)
P6500: Solid front with pressure relief back and
ventable fill plug on top
Movement: 304 stainless steel
Window Material: Safety glass (STD.), acrylic (OPT.)
Diaphragm Material: ≤ 80 IW - 316Ti,
NON-WETTED COMPONENTS
≥ 80 IW - Duratherm® (NiCrCo alloy)
Hastelloy® C-276 (OPT.) Case Bayonet Ring Window
Aluminum, white background, black figures and Safety glass (STD.)
Dial: 316L SS (STD.) 316L SS (STD.)
intervals Safety glass, acrylic (OPT.)
Pointer: Aluminum black MIN/MAX TEMPERATURE LIMITS
Overpressure Protection: 5 times and 10 times (OPT.), up to 580 psi Version Ambient Process Storage

Dry: IP66 and NEMA 4x -4°F to 140°F -4°F to 185°F -40°F to 158°F
Dry
Weather Protection: Liquid filled/hermetically sealed: IP66/67 and (-20°C to 60°C) (-20°C to 85°C) (-40°C to 70°C)
NEMA 4X 19°F to 140°F 19°F to 185°F -4°F to 158°F
Glycerin
Mounting: Stem, flanged (-7°C to 60°C) (-7°C to 85°C) (-20°C to 70°C)
WETTED COMPONENTS -4°F to 140°F -20°F to 140°F -40°F to 158°F
Silicone
(-20°C to 60°C) (-29°C to 60°C) (-40°C to 70°C)
Diaphragm Lower Housing Other
-4°F to 140°F -4°F to 185°F -4°F to 140°F
316Ti SS ATEX
(-20°C to 60°C) (-20°C to 85°C) (-20°C to 60°C)
Hastelloy® 316 SS
O-Ring, Viton *Accuracy at temperatures above or below the referenceambient
C-276 Hastelloy® C-276
temperatures of 68°F (20°C) will be affected by approximately 0.8%
Duratherm® per 25°F.

1 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258
Data Sheet
P5500 and P6500 Low Pressure
Diaphragm Gauges

ORDERING CODE Example: 10P5500 S S D T 04 L 00 00000 10IW XPD


Dial Size/Model Code
10P5500 - 100mm open front diaphragm pressure gauge 10P5500
16P5500 - 160mm open front diaphragm pressure gauge
10P6500 - 100mm solid front diaphragm pressure gauge
16P6500 - 160mm solid front diaphragm pressure gauge
Diaphragm
H - Hastelloy® C-276
S - 316Ti Stainless steel, Duratherm® S
Lower Housing
H - Hastelloy® C-276
S - 316 Stainless steel S
Case Design
D - Dry case D
L - Liquid filled case, glycerin (STD.), (for ranges ≥ 40 IW only)
Process Connection Type
T - Threaded T
F - Flanged
Process Connection Sizes
00 - Flanged process connection
02 - 1/4 NPT Male
04 - 1/2 NPT Male 04
Process Connection Location
L - Lower L
Flange Connection Sizes
00 -Threaded process connection 00
50 -1/2˝ NPS
10 - 1˝ NPS
15 -11/2˝ NPS
20 - 2˝ NPS
30 - 3˝ NS
Flange Ratings
00000 - Threaded process connection 00000
150RF -150# Raised Face Flange
300RF - 300# Raised Face Flange
Range (coding example only, see range table on page 3 for all standard ranges)
10IW - 10 Inches of water 10IW
Options (If choosing an option(s) must include an “X”) (for more options, see table 2 on page 4) X__
PD - Acrylic window PD

2 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258
Data Sheet
P5500 and P6500 Low Pressure
Diaphragm Gauges

TABLE 1 - STANDARD RANGES


  Other ranges and engineering units available

psi inH2O mbar bar kPa mPa kg/cm² mmH2O cmH2O mmHG
N0.2/0.2# N16/0IW N16/0MB N1/0BR N2.5/0KP N0.01/0.01MP N1/0KG N160/0MW N100/100CW N600/0MM
N0.4/0.25# N40/0IW N25/0MB N0.6/0BR N4/0KP N0.0016/0MP N0.0125/0.0125KG N250/0MW N400/400CW 0/100MM
N5/5# N5/5IW N40/0MB N0.1/0BR N6/0KP 0/0.016MP N0.05/0.05KG N400/0MW 0/160MM
N14.5/43.5# N10/10IW N60/0MB N0.1/0.1BR N10/0KP 0/0.04MP N0.1/0.1KG N600/0MW 0/200MM
N14.5/130.5# N10/20IW N100/0MB N0.1/0.15BR N16/0KP 0/0.06MP N0.5/0.5KG N1000/0MW 0/300MM
N2/0# N10/40IW N250/0MB N0.1/2BR N40/0KP 0/0.4MP N1/2KG N1600/0MW
N3.6/0# N15/15IW N400/0MB N0.15/0.25BR N60/0KP 0/0.6MP N1/5KG N2500/0MW
N6/0# N20/20IW N600/0MB N0.2/0.2BR N100/0KP 0/1MP N1/24KG N4000/0MW
N15/0# N50/50IW N10/10MB N0.5/0.5BR N0.8/0.8KP 0/1.6MP 0/0.04KG N6000/0MW
0/1# N100/100IW N12.5/12.5MB N1/0.6BR N1/1KP 0/2.5MP 0/0.1KG N1000/0MW
0/3# 0/10IW N15/10MB N1/1BR N3/3KP 0/0.2KG N50/200MW
0/4# 0/15IW N16/16MB N1/3BR N4/4KP 0/0.6KG N50/500MW
0/5# 0/30IW N20/20MB N1/4BR N10/10KP 0/1KG N100/150MW
0/6# 0/40IW N30/30MB N1/5BR N12.5/12.5KP 0/2.5KG N100/400MW
0/8# 0/50IW N40/40MB N1/24BR N20/20KP 0/4KG N100/500MW
0/9# 0/100IW N50/50MB 0/0.025BR N30/30KP 0/10KG N100/1000MW
0/10# 0/160IW N60/60MB 0/0.06BR N100/100KP 0/16KG N125/125MW
0/15# N80/80MB 0/0.1BR N100/2400KP 0/25KG N500/500MW
0/30# N100/100MB 0/0.15BR N1250/1250KP 0/160MW
0/35# N250/250MB 0/0.16BR 0/1.6KP 0/200MW
0/60# N1000/1000MB 0/0.2BR 0/5KP 0/250MW
0/85# 0/16MB 0/0.25BR 0/6KP 0/400MW
0/100# 0/25MB 0/0.3BR 0/10KP 0/500MW
0/140# 0/30MB 0/0.4BR 0/20KP 0/600MW
0/200# 0/40MB 0/0.6BR 0/40KP 0/750MW
0/220# 0/60MB 0/1BR 0/60KP 0/1000MW
0/232# 0/100MB 0/1.6BR 0/100KP 0/1210MW
0/300# 0/160MB 0/2BR 0/160KP 0/1600MW
0/200MB 0/2.5BR 0/250KP 0/2000MW
0/250MB 0/4BR 0/400KP 0/2500MW
0/400MB 0/6BR 0/600KP 0/3000MW
0/500MB 0/7BR 0/1000KP 0/4000MW
0/600MB 0/10BR 0/1600KP 0/5000MW
0/1000MB 0/11BR 0/2500KP 0/6000MW
0/1600MB 0/14BR 0/4000KP
0/16BR
0/20BR
0/25BR

3 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258
Data Sheet
P5500 and P6500 Low Pressure
Diaphragm Gauges

TABLE 2 - OPTIONS
Code Description Notes
DA Dial marking Information is required by the customer
GV Silicone case fill
GX Halocarbon filled case
Maximum protection up to 580 psi. Not available for ranges below
HP Overpressure protection 10-times F.S.
10IW and vacuum or compound ranges
5G Instrument assembled to accessory
MQ Positive material certificate (PMI)
NH Stainless steel tag wired to case Information is required by the customer
PD Polycarbonate window
C3 Certificate according to EN 10204 3.1 C3
C4 CD-4 calibration certificate
HY Hydrostatic pressure test HY Only available with overload protection (Option HP)
EP Maximum pointer With acrylic window only, 100mm only
AT ATEX Approval
E6 Six O’clock stop pin
VS Underload stop 40inH20 and above only
MP Micrometer adjustable pointer
EA External zero Standard with liquid filled gauge not available with option code MP

4 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258
Data Sheet
P5500 and P6500 Low Pressure
Diaphragm Gauges

DIMENSIONS in [ ] are decimal inches


  For reference only, consult Ashcroft for specific dimensional drawings.

P5500, 100 mm, (Range < 15 psi) P5500, 160 mm (Range < 15 psi)
B1
ØA
[0.2] [0.69]
5.0mm 18.0mm

B1

[0.2] [0.71]
5.0mm 18.0mm

ØA

C1 C1

[0.87]
Across Flats 22.0mm Across Flats 22.0mm
Possible Process Possible Process
Connection, Connection,
Threads See Table ØD Threads See Table
ØD

P5500, 100 mm, (Range ≥ 15 psi) P6500, 160 mm (Range ≥ 15 psi)


ØA B
[0.69]
18.0mm
B
[0.71]
18.0mm

ØA

C C

H
H

[0.87]
Across Flats 22.0mm Across Flats 22.0mm
Possible Process
Possible Process Connection,
Connection, Threads See Table
Threads See Table ØD ØD

PRESSURE
SIZE ØA B B1 C C1 ØD H
RANGE

[3.97] [2.01] [2.38] [0.73] [1.02] [3.90] [5.04]


100
101 51 61 18.5 26 99 128
≥ 0.6 bar
[6.35] [1.96] [2.52] [0.76] [1.11] [3.90] [5.04]
160
161 50 64 17 28 99 128

[3.97] [2.01] [2.38] [0.73] [1.02] [6.18] [4.92]


100
101 51 61 18.5 26 157 125
≤ 400 mbar
[6.35] [1.96] [2.52] [0.76] [1.11] [6.18] [4.92]
160
161 50 64 17 28 157 125

5 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258
Data Sheet
P5500 and P6500 Low Pressure
Diaphragm Gauges

DIMENSIONS in [ ] are decimal inches


  For reference only, consult Ashcroft for specific dimensional drawings.

P6500, 100 mm [2.38] P5500, 160 mm [1.96]


61.0mm 50.0mm
[6.35]
[3.97] Ø 161.0mm
Ø 101.0mm [0.71] [0.69]
18.0mm 18.0mm

[0.20]
5.0mm

[1.02]
26.0mm
H3

[0.67]
17.0mm

H3
M
ØG
ØK
Ø D1
M
ØG
ØK
Ø D1

P5500, 100 mm [2.01]


51.0mm
[3.97] SIZE Ø D1
Ø 101.0mm [0.20] [0.71]
5mm 18.0mm FLANGE ≥ 0.6 ≤ 400 ØG H3 ØK M
RATING* bar mbar
[4.25] [2.00] [5.75] [3.12]
- 4 x ½-13 UNC
108 50.8 146 79.2
1˝ 150
[4.25] [2.00] [5.79] [3.12]
- 4 x ½-13 UNC
[0.73]
108 50.8 147 79.2
18.5mm
[4.88] [2.00] [5.94] [3.50]
- 4 x 5⁄8-11 UNC
H3

123.9 50.8 151 88.9


1˝ 300
[4.88] [2.00] [5.98] [3.50]
- 4 x 5⁄8-11 UNC
123.9 50.8 152 88.9
[4.92] [2.87] [5.83] [3.87]
M - 4 x ½-13 UNC
125.0 73.0 148 98.4
1½˝ 150
ØK
[4.92] [2.87] [5.87] [3.87]
Ø D1 - 4 x ½-13 UNC
125.0 73.0 149 98.4
P6500, 160 mm [6.10] [2.87] [5.63] [4.50]
[2.52] - 4 x 3⁄4-10 UNC
[6.35]
64.0mm 155.0 73.0 143 114.3
Ø 161.0mm 1½˝ 300
[0.69] [6.10] [2.87] [5.67] [4.50]
18.0mm - 4 x 3⁄4-10 UNC
155.0 73.0 144 114.3
[6.18] [3.63] [6.02] [4.75]
- 4 x 5⁄8-11 UNC
157.0 92.1 153 120.7
2˝ 150
[6.0] [3.63] [5.47] [4.75]
- 4 x 5⁄8-11 UNC
152.4 92.1 139 120.7
[6.50] [3.63] [5.63] [4.75]
- 8 x 5⁄8-11 UNC
165.0 92.1 143 120.7
1.11] 2˝ 300
[6.50] [3.63] [5.28] [4.75]
28.0mm
- 8 x 5⁄8-11 UNC
165.0 92.1 134 120.7
H3

Through Hole
[7.52] [5.00] [5.47] [6.00]
- [0.75]
190.9 127 139 152.4
8 x 5⁄8-11 UNC
3˝ 150
Through Hole
M [7.52] [5.00] [5.47] [6.00]
- [0.75]
ØG 190.9 127 139 152.4
ØK 8 x 5⁄8-11 UNC
Ø D1

* 1½˝ Process connection not available with P6500

6 of 6
All specifications are subject to change without notice. ashcroft.com
All sales subject to standard terms and conditions. [email protected]
©2019 Ashcroft Inc. P5500-6500_gauge_ds_RevB_11-14-19 1.800.328.8258