0% found this document useful (0 votes)
554 views12 pages

MS 1248u

This product manual summarizes an 8 channel scanner with USB data logging capabilities. It includes: - Technical specifications for the MS-1248 U 8 channel scanner including temperature ranges, relay outputs, power supply, and operating conditions. - A diagram of the terminal connections for the 8 temperature input channels and 4 relay outputs. - Procedures for configuring the input selection, relay modes, set points, offsets, and real-time clock settings. - Details on the menu options for changing parameters like set values, input skips, relay groups, and modes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
554 views12 pages

MS 1248u

This product manual summarizes an 8 channel scanner with USB data logging capabilities. It includes: - Technical specifications for the MS-1248 U 8 channel scanner including temperature ranges, relay outputs, power supply, and operating conditions. - A diagram of the terminal connections for the 8 temperature input channels and 4 relay outputs. - Procedures for configuring the input selection, relay modes, set points, offsets, and real-time clock settings. - Details on the menu options for changing parameters like set values, input skips, relay groups, and modes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Product Manual

8 Channel Scanner
with USB Data Logger

MS-1248 U

Multispan Control Instruments Pvt Ltd


72/B, Phase 1, GIDC Estate, Vatva, Ahmedabad-382445, Gujarat, India.
+91-79-40029250 +91-9978991471
[email protected] www.multispanindia.com

MS-1248 U www.multispanindia.com
Product Inception

Upper Display
( RED )
Lower Display
( GREEN )

USB Storage Full 4 Relay Indication


Indication
Channel and
Alarm
USB Port Indication

To go to
To save changes
Parameter
in settings
Setting
To change the value
or select option

Technical Specifications

Model MS 1248U
UPPER: 4 Digit 7 seg 0.70 , RED LED Display
Display
LOWER: 4 Digit 7 seg 0.50 , GREEN LED Display
Size (mm) 96 (H) X 96 (W) X 50 (D) mm
Panel Cutout 92 X 92 mm
Input J TYPE, K TYPE, PT-100 3Wire Selectable
Temperature J : 0 To 600 / K: 0 TO 1200 / PT-100: -99 To 400 /
Range PT.1: -99.0 To 400.0

Output 4 Relay, (NO-C-NC) 1C/O 5A@230V AC , USB Data Logging Facilty


5A for Resistive load
Power Supply 100 to 250V AC,50/60 Hz, Approx 4VA
Operating
0 To 55
Temperature
Relative Up to 95% RH Non Condensing
Humidity

MS-1248 U Page - 1 www.multispanindia.com


Procedure

1) Do all connection as per the wiring diagram


2) To Configure: 1. Input Selection
2. Relay mode
- If 1 Relay per group - If 2 Relay per group
LOW LOW / HIGH
HIGH HIGH / TRIP
HIGH / LOW
3. Set point Selection
4. Offset Setting
5. RTC Setting
Note :- Dp selection for PT-100/3Wire Only.
3) If needed to add offset, press + together.
Set offset for each channel if required.
Off set range will be ±25 for J, K, PT-100 temperature input.
Off set range will be ±25.0 for PT.1 when DP is selected YES.
4) Press & Hold key for auto scrolling or manual scrolling.
5) In hold mode use & key to select next channel.

Terminal Diagram

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
PT-100/3W PT-100/3W PT-100/3W PT-100/3W PT-100/3W

+
T/C
-CH-1
+
T/C
-
CH-2
+
T/C
-CH-3
+
T/C
-CH-4
+
T/C
-CH-5

NC C NO NC C NO NC C NO NC C NO
100 ~
250V AC R1 R2 R3 R4
50/60 Hz
4VA ! + T/C -
CH-8
+ T/C -
CH-7
+ T/C -
CH-6

PT-100/3W PT-100/3W PT-100/3W


L N 24 23 22 21 20 19 18 17 16

MS-1248 U Page - 2 www.multispanindia.com


Main Menu: To change set value & hystersis based on relay mode & grouping

For Example:

In Group No 1 If 1st channel, have a set point as a high alarm, 1 relay


In Group No 2 If 2nd channel, have a set point as a low alarm, 1 relay
For, 3rd, 4th, 5th, 6th, 7th, 8th channel have a set point as high & low alarm, 2 relay

MENU-1

Input Selection

Press + SET key.

 Scan time.

Press key.

 
 / 

Use or key to Skip or Unskip Channel.
Press key.

 
 / 


(Repeat the same procedure for all 8 channels).
Press key.

 To change the Input Type, Press or Key.


 ( J, K , PT-100,PT.1).
Press key.

 (Repeat the same procedure for all 8 channels).




Press key.

Press ENT key to save & exit.

Note: Set value can be changed by or key.

MS-1248U Page - 3 www.multispanindia.com


Key Operation Note: Set value can be changed by or key.

1) Press SET key to enter in set value menu.


2) Press & Key to change the parameter setting.
3) Press + SET Key to enter in parameter menu
(Input selection, skip-unskip selection)
4) Press + SET Key to enter in group menu for relay
mode selection.
5) Press + Key to set OFFSET.
6) Press & hold key to enter in scroll & hold mode.

Menu: 2

To configurable no.of channel per group. (User can define maximum


4 group & maximum 8 channel/group), relay mode

Relay menu
Press SET + key

Repeat for 8  Set yes or no for channel by press or key.


Channel 
Press SET key to go to next parameter

Press SET key to output relay select.

 Select no of output relay by 


Press SET key  press & key.  Press SET key

to go to next to go to next
parameter parameter

  ST nd

  1 Relay Low & 2 High Relay


Set output of relay
/ Low and High
 Low
or
 High  ST nd

/ High and Low  1 Relay High & 2 Relay Trip
by press or key / High and Trip

Press SET key to next group(if relay exist)

Press key to exit

MS-1248U Page - 4 www.multispanindia.com


Note: Set value can be changed by or key.

MENU-3

Set point Selection


Press SET key.

 Low / High set point-1



Press SET key.

 High / Trip set point for Group1,



Press SET key. (Repeat the same procedure for all 4 group).

 Low / High set point for Group 4,



Press SET key.

 High / Trip set point for Group 4,



Press SET key.
 Hysteresis-1

Press SET key.


 (Repeat the same procedure for all 4 Hysteresis)
Press SET key.

Press key to save & exit.

MENU-4

OFFSET Setting
Press & key to change offset

 Press key to change offset



Press key to go to next channel
 (Repeat the same procedure for all 8 channels)


 Change offset point -25 to +25 by using or key.



Press set key to go to next channel

MS-1248U Page - 5 www.multispanindia.com


Note: Set value can be changed by or key.

RTC Setting
MENU-5
Press & key to access RTC Parameter.

 1-999.
 USB Save Time.
Press SET key.


If password 
is not 25.
If password is
25.
Press SET key.
 (0-59)
 Second.
Press SET key.

 (0-59)
 Minute.
Press SET key.

 (0-23)
 Hour.
Press SET key.

 (1-31)
 Date.
Press SET key.

 (1-12)
 Month.
Press SET key.

 (0-99)
Press SET key.  Year.

Press ENT key to save & exit.

MS-1248 U Page - 6 www.multispanindia.com


USB Excel Sheet Format

MS-1248 U
Note :- Up to 8000 Values can be stored in internal memory, and after internal memory reaches to 5800 values Memory full
indication LED start blinking which means memory is about to full.

Date Time Channel 1 Channel 2 Channel 3 Channel 4 Channel 7 Channel 8


1/06/2018 14:22:31 45 42 39 35 35 33
1/06/2018 14:22:32 46 42 39 36 36 33
1/06/2018 14:22:33 46 42 39 36 36 34
1/06/2018 14:22:34 46 43 39 36 37 34

Page - 7
1/06/2018 14:22:35 46 43 39 36 37 34
1/06/2018 14:22:36 46 43 40 36 37 34
1/06/2018 14:22:37 46 43 40 37 37 34
1/06/2018 14:22:38 46 43 40 37 37 34
1/06/2018 14:22:39 46 43 40 37 37 34

1/06/2018 14:22:40 46 43 40 37 37 34

www.multispanindia.com
Mechanical Installation

B E F

A
D

Right Side View

Top View

MODEL A B C D E F G
DIMENSIONS 100mm 100mm 90mm 90mm 3mm 53mm 56mm

MS-1248 U Page - 8 www.multispanindia.com


Safety Precautions
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
=> Read complete instructions prior to installation and operation of the unit.
WARNING : Risk of electric shock.

Warning Guidelines
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the
wiring arrangement. Do not touch the terminals while power is being supplied.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of
equal size shall be made with shortest connection. 2
3) Cable used for connection to power source, must have a cross section of (1mm) or greater. These wires
should have insulations capacity made of at least 1.5kV.
4) When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring
for the RTD type, use a wiring material with a small lead resistance (5 max per line)and no resistance
differentials among three wires should be present.
5) A better anti-noise effect can be expected by using standard power supply cable for
the instrument.

Installation Guidelines
1) This equipment, being built-in-type, normally becomes a part of main control panel and in such case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ON or OFF function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.

Mechanical Installation
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.

Maintenance
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any
other cleaning agent.
3) Fusible resistor must not be replaced by operator.

MS-1248 U Page - 9 www.multispanindia.com


Note :

MS-1248 U Page - 10 www.multispanindia.com


Note :

Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474 /76 /82 or Email at : [email protected]