T1ducttype PDF
T1ducttype PDF
CONTENTS
1. MODELS LIST ................ .......................................................................................................... 2
2. NOMENCLATURE ................................................................................................................... 3
3. FEATURES .............................................................................................................................. 3
1 MODELS LIST
Nominal Capacity Model Power Supply
Model Name
Ton Refrigerant Ph, V, Hz
B-series C-series
FG20/B-G FG20/C-M
5.7 R22 3,380,50
FGR20/B-G FGR20/C-M
FG25/B-G FG25/C-M
7.1 R22 3,380,50
FGR25/B-G FGR25/C-M
FG30/B-G FG30/C-M
8.5 R22 3,380,50
FGR30/B-G FGR30/C-M
FG40/B-G FG40/C-M
11.4 R22 3,380,50
FGR40/B-G FGR40/C-M
FG55/B-G
15.6 R22 3,380,50
FGR55/B-G
FG65/B-G
18.5 R22 3,380,50
FGR65/B-G
FG50/B(2)-G
14.2 R22 3,380,50
FGR50/B(2)-G
FG60/B(2)-G
17.1 R22 3,380,50
FGR60/B(2)-G
2 NOMENCLATURE
FG / ( ) - ( )
1 2 3 4 5 6 7
No Description Options
1 Ducted type air conditioner
Heat pump type-R
2 Product type
Cooling only type-omitted
3 Cooling capacity Nominal cooling capacity (kW)
B-the second improvement;A-the first improvement
4 Design sequence C-depressed cost improvement
Omitted-the basic design
(2)-two outdoor units
5 Outdoor unit number
Omitted-one outdoor unit
M=3Ph,380V,50Hz;3Ph,400V,50Hz; 3Ph,420V,50Hz;
6 Power supply code K=1Ph,220~240V,50Hz ;1Ph,230~240V,50Hz
H=3Ph,380V,60Hz
(O)-Outdoor unit
7 Indoor and outdoor unit code (I)-Indoor unit
Omitted-whole unit
3 FEATURES
3.1 Description
GREE FG Series Ducted type Air-conditioning Units has combined the comfort, top grade from the
central air conditioners as well as the convenient installation and facility from the mini type of the split
air conditioners.
GREE FG Series Ducted type can offer the perfect combination of superior product quality、operating
efficiency and value for money. These units are available in vertical discharge configurations, as cool
only models. All capacities are rated according to the relevant National Standards. These units are
manufactured under strict quality control with full conformance to ISO 9001:2000 and ISO 14001
standards.
Indoor fan motor and motor are rotated by belt roller, so indoor outlet static pressure could be
adjusted within certain range.Outdoor unit air outlet is upward. The capacity range is 20kW to 60kW.
It could be sufficient to the different requirements from customers.
The FG Series Ducted Air-conditioning Units can be widely used in small supermarkets, chain stores,
hotels, restaurants, offices and meeting rooms etc. It's especially fit for the small commercial and
industrial application.
d
Features Description
The coil is constructed of golden aluminum sheet and inner groove
Quality condenser coil
copper pipe
Coil protected Coils are protected from damage by a metal grill.
High / low pressure protection、Discharge high temperature protection、
Protected compressor Overload protection、Reverse (open) phase protection、Sensor
malfunction alarm
Cabinet is made of pre-painted steel. The pre-treated flat galvanized
steel provides a better paint to steel bond, which resists corrosion and
Resisting corrosion
rust creep . Special primer formulas ensure minimal fading when
exposed to sunlight.
Low operating sound level Low noise fan and low noise compressor with isolator
Low maintenance Quality compressor and motor are used
All units are factory tested prior to dispatch to verify system operation
Factory tested
and control functioning before shipment
Features Description
Condensing water tube and refrigerant tube are in same direction,
Flexible installation
it's better for installation
It adopts high static pressure design, so air is centralized handling in the
Long-distance duct air supply
indoor unit and implant long-distance duct air supply
The capacity range The capacity range is 20kW to 60kW
Convenient operation Simple controller and intelligent remote controller make unit more
convenient operation.
It can connect many supply-air outlet to the duct, so that it can make the
temperature and humidity of the whole room equality, meanwhile, it can
Good indoor air quality
lead in fresh air, makes well indoor unit air quality. All units are provided
with filters that are easily accessible from the rear of the unit.
The controls provide for compressor delay protection, Remote control
Microcomputer Control function ,temperature setting ,fan function,Sleep function,Memory
function, Self-diagnosis with alarm function.
Evaporator coils are constructed of inner groove copper tube and
Quality evaporator coil
hydrophilic aluminum sheet.
Low operating sound The fan motors are resilient mounted to minimize vibration and noise
4
Duct Type Split Air Conditioners Technical Sales Guide
4 PRODUCT DATA
4.1 Product Data at Rated Condition
FG(R) /B-G(I)
Indoor unit
20 25 30 40
Models
FG(R) /B-G(O)
Outdoor unit
20 25 30 40
Btu/h 68243 85304 102360 136490
Cooling
Nominal Capacity 20 25 30 40
At Rated ESP Btu/h 78479 95540 112601 146722
Heating
23 28 33 43
Power Supply V/Ph/Hz 380/3/50
Cooling 8.5 10.2 12.1 17.0
Power Consumption
Heating 6.8 8.7 10.1 14
Cooling A 15.8 18.9 21.8 31.9
Running Current
Heating A 13.5 16.8 18.3 27.3
Refrigerant Type R22
Refrigerant Charge 7.0 8.0 12.0 13.2
Power Supply V/Ph/Hz 380/3/50
Fan Type Centrifugal / Belt Drive
CFM 2354 2825 3237 4120
Air flow
4000 4800 5500 7000
Input Power W 1100 1100 1500 2200
Fan
Running Current A 2.8 3.0 3.6 4.5
0.36 0.36 0.52 0.52
Rated ESP
Pa 90 90 130 130
Fan Motor Protection Overload Protection
Sound Pressure Level dB(A) 54 54 57 58
Indoor
Note
5
d
Note
6
Duct Type Split Air Conditioners Technical Sales Guide
Note
1. The design is according to GB/T 18836—2002 standard.
2. The parameter here might be changed by the factory, please refer to the name plate for the lasted one.
3. The Auxiliary Heater is optional.
4. this parameter table is only for the unit without auxiliary heater,which one with auxiliary heater please refer to the nameplate.
7
d
8
Duct Type Split Air Conditioners Technical Sales Guide
9
d
10
Duct Type Split Air Conditioners Technical Sales Guide
11
d
Model: FG(R)55/B-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 51.9 177.2 37.0 126.2 60.3 205.7 36.6 125.0 62.1 211.8 31.0 105.7
24 75.2 52.4 178.8 42.3 144.3 60.9 207.8 39.0 132.9 62.7 214.0 34.4 117.5
9348 5502 140 0.56
27 80.6 53.5 182.4 41.5 141.6 61.4 209.6 41.0 140.0 63.3 215.9 37.9 129.2
31 87.6 54.2 184.9 43.3 147.6 62.0 211.7 42.6 145.5 63.9 218.0 41.5 141.5
23 73.4 51.2 174.6 36.4 124.4 59.4 202.6 36.1 123.1 61.2 208.7 30.5 104.2
24 75.2 51.6 176.2 41.7 142.2 60.0 204.7 38.4 131.0 61.8 210.8 33.9 115.7
9000 5297 160 0.64
27 80.6 52.7 179.7 40.9 139.5 60.5 206.5 40.4 137.9 62.4 212.8 37.3 127.3
31 87.6 53.4 182.2 42.6 145.4 61.1 208.5 42.0 143.4 63.0 214.8 40.8 139.4
23 73.4 50.4 172.0 35.9 122.5 58.5 199.6 35.5 121.3 60.2 205.5 30.1 102.6
24 75.2 50.9 173.5 41.0 140.0 59.1 201.6 37.8 129.0 60.9 207.7 33.4 114.0
8579 5049 180 0.72
27 80.6 51.9 177.0 40.3 137.4 59.6 203.4 39.8 135.8 61.4 209.6 36.8 125.4
31 87.6 52.6 179.5 42.0 143.2 60.2 205.4 41.4 141.2 62.0 211.6 40.2 137.3
12
Duct Type Split Air Conditioners Technical Sales Guide
Model: FG(R)65/B-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 56.3 192.2 40.1 136.9 65.4 223.1 39.7 135.6 67.3 229.7 33.6 114.7
24 75.2 56.8 194.0 45.9 156.5 66.0 225.4 42.3 144.2 68.0 232.1 37.3 127.4
9348 5502 140 0.56
27 80.6 58.0 197.8 45.0 153.6 72.6 227.4 44.5 151.8 68.7 234.2 41.1 140.2
31 87.6 58.8 200.6 46.9 160.1 67.3 229.6 46.3 157.8 69.3 236.5 45.0 153.4
23 73.4 55.5 189.4 39.5 134.9 64.4 219.8 39.1 133.6 66.3 226.4 33.1 113.0
24 75.2 56.0 191.1 45.2 154.2 65.1 222.0 41.6 142.1 67.0 228.7 36.8 125.5
9000 5297 160 0.64
27 80.6 57.1 194.9 44.3 151.3 71.5 224.0 43.8 149.6 67.6 230.8 40.5 138.1
31 87.6 57.9 197.6 46.2 157.7 66.3 226.2 45.6 155.5 68.3 233.0 44.3 151.2
23 73.4 54.7 186.5 38.9 132.9 63.5 216.5 38.6 131.6 65.3 223.0 32.6 111.3
24 75.2 55.2 188.2 44.5 151.9 64.1 218.7 41.0 139.9 66.0 225.3 36.2 123.7
8579 5049 180 0.72
27 80.6 56.3 192.0 43.7 149.0 70.4 220.6 43.2 147.3 66.6 227.3 39.9 136.1
31 87.6 57.1 194.7 45.5 155.3 65.3 222.8 44.9 153.2 67.3 229.5 43.6 148.9
13
d
Model: FG(R)50/B(2)-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 47.2 161.1 33.6 114.7 54.8 187.0 33.3 113.6 56.4 192.5 28.2 96.1
24 75.2 47.6 162.5 38.4 131.2 55.3 188.8 35.4 120.8 57.0 194.5 31.3 106.8
9348 5502 140 0.56
27 80.6 48.6 165.8 37.7 128.7 55.8 190.5 37.3 127.2 57.5 196.3 34.4 117.5
31 87.6 49.3 168.1 39.3 134.1 56.4 192.4 38.8 132.3 58.1 198.2 37.7 128.6
23 73.4 46.5 158.7 33.1 113.0 54.0 184.2 32.8 111.9 55.6 189.7 27.8 94.7
24 75.2 46.9 160.1 37.9 129.2 54.5 186.0 34.9 119.0 56.2 191.6 30.8 105.2
9000 5297 160 0.64
27 80.6 47.9 163.3 37.2 126.8 55.0 187.7 36.7 125.3 56.7 193.4 33.9 115.7
31 87.6 48.5 165.6 38.7 132.2 55.6 189.6 38.2 130.3 57.2 195.2 37.1 126.7
23 73.4 45.8 156.3 32.6 111.3 53.2 181.4 32.3 110.2 54.8 186.8 27.3 93.3
24 75.2 46.2 157.7 37.3 127.3 53.7 183.3 34.4 117.2 55.3 188.7 30.4 103.6
8579 5049 180 0.72
27 80.6 47.2 160.9 36.6 124.9 54.2 184.9 36.2 123.5 55.8 190.5 33.4 114.0
31 87.6 47.8 163.1 38.2 130.2 54.7 186.7 37.6 128.3 56.4 192.3 36.6 124.8
14
Duct Type Split Air Conditioners Technical Sales Guide
Model: FG(R)60/B(2)-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 57.2 195.1 40.7 139.0 66.4 226.5 40.3 137.6 68.4 233.2 34.1 116.4
24 75.2 57.7 196.9 46.6 158.9 67.1 228.8 42.9 146.4 69.1 235.6 37.9 129.4
11425 6724 140 0.56
27 80.6 58.9 200.9 45.7 155.9 67.0 230.8 45.2 154.1 69.7 237.8 41.7 142.3
31 87.6 59.7 203.6 47.6 162.5 68.3 233.1 47.0 160.2 70.4 240.1 45.7 155.8
23 73.4 56.3 192.2 40.1 137.0 65.4 223.1 39.7 135.6 67.3 229.8 33.6 114.7
24 75.2 56.9 194.0 45.9 156.6 66.1 225.4 42.3 144.2 68.0 232.2 37.4 127.5
11000 6474 160 0.64
27 80.6 58.0 197.9 45.0 153.6 66.0 227.4 44.5 151.9 68.7 234.3 41.1 140.2
31 87.6 58.8 200.6 46.9 160.1 67.3 229.7 46.3 157.9 69.3 236.5 45.0 153.5
23 73.4 55.5 189.4 39.5 134.9 64.4 219.8 39.1 133.6 66.3 226.3 33.1 113.0
24 75.2 56.0 191.1 45.2 154.2 65.1 222.0 41.6 142.0 67.0 228.7 36.8 125.5
10485 6171 180 0.72
27 80.6 57.1 194.9 44.3 151.3 65.0 224.0 43.8 149.6 67.6 230.8 40.5 138.1
31 87.6 57.9 197.6 46.2 157.7 66.3 226.2 45.6 155.5 68.3 233.0 44.3 151.2
15
d
16
Duct Type Split Air Conditioners Technical Sales Guide
FGR20/B-G、FG20/B-G
FGR20/C-M、FG20/C-M
External Static Pressure(Pa)
110 0.44
100 0.40
90 0.36
80 0.32
70 0.28
4154 4000 3813 2445 2354 2244
FGR25/B-G、FG25/B-G
FGR25/C-M、FG25/C-M
External Static Pressure(Pa)
120 0.48
110 0.44
100 0.40
90 0.36
80 0.32
70 0.28
4895 4800 4575 2934 2825 2693
FGR30/B-G、FG30/B-G
FGR30/C-M、FG30/C-M
External Static Pressure(Pa)
160 0.64
150 0.60
140 0.56
130 0.52
120 0.48
110 0.44
5712 5500 5243 3362 3237 3086
17
d
FGR40/B-G、FG40/B-G
FGR40/C-M、FG40/C-M
External Static Pressure(Pa)
150 0.60
140 0.56
130 0.52
120 0.48
110 0.44
7270 7000 6672 4279 4120 3927
3
Air Flow(m /h) Air Flow(CFM)
FGR50/B(2)-G、FG50/B(2)-G
External Static Pressure(Pa)
190 0.76
180 0.72
170 0.68
160 0.64
150 0.60
140 0.56
11425 11000 10485 6724 6474 6171
FGR55/B-G、FG55/B-G
External Static Pressure(Pa)
190 0.76
180 0.72
170 0.68
160 0.64
150 0.60
140 0.56
9348 9000 8579 5502 5297 5049
18
Duct Type Split Air Conditioners Technical Sales Guide
FGR65/B-G、FG65/B-G
External Static Pressure(Pa)
180 0.72
170 0.68
160 0.64
150 0.60
140 0.56
11425 11000 10485 6724 6474 6171
6 CLEARANCE DATA
6.1 Outdoor Unit
>1000 >1200
>1000
>
19
d
>1000 >560
Air supply
>1000
Air return
20
Duct Type Split Air Conditioners Technical Sales Guide
7 DIMENSION DATA
7.1 Outdoor Unit
Unit: mm
Model A B C
FG(R)20/C-M(O) 1150 360 1350
FG(R)25/C-M(O) 1150 422 1600
840
1772
A 880 B±2
C±2
844±2
21
d
Unit: mm
Model A B C
FG(R)20/B-G(O)、FG(R)25/B-G(O)、FG(R)30/B-G(O) 990 787 337
FG(R)40/B-G(O) 1290 1160 850
FG(R)30/ C-M (O) 990 787 337
FG(R)40/C-M(O) 1290 1160 850
Note
Unit: mm
Model A B C D E F H
FG(R)55/B-G(O)
1980 840 920 1400 460 880 1760
FG(R)65/B-G(O)
22
Duct Type Split Air Conditioners Technical Sales Guide
B
Air Return F Air Oulet E
D C
A
A
FG(R)20/B-G(I)、FG(R)25/B-G(I) FG(R)40/B-G(I)、FG(R)50/B(2)-G(I)
FG(R)30/B-G(I) FG(R)60/B(2)-G(I)、FG(R)55/B-G(I)
FG(R)20/C-M(I) FG(R)30/C-M(I) FG(R)65/B-G(I)
FG(R)25/C-M(I) FG(R)40/C-M(I)
Unit: mm
Model A B C D E F
FG(R)20/B-G(I)
FG(R)25/B-G(I) 1560 910 1194 1194 292 342
FG(R)30/B-G(I)
FG(R)40/B-G(I) 1780 1040 868 1450 347 555
FG(R)50/B(2)-G(I) 1980 1040 1120 1650 347 600
FG(R)60/B(2)-G(I) 1980 104 1120 1650 347 755
FG(R)55/B-G(I) 1980 1040 1120 1650 347 600
FG(R)65/B-G(I) 1980 104 1120 1650 347 755
FG(R)20/C-M(I)
1560 910 331 1194 292 342
FG(R)25/C-M(I)
FG(R)30/C-M(I) 1560 910 1194 1194 292 342
FG(R)40/C-M(I) 1780 1040 868 1450 347 555
23
d
7.3 Controller
Remote Controller(Optional)
85
158.7
85
Central Controller(Optional)
96
56
96
24
Duct Type Split Air Conditioners Technical Sales Guide
8 WIRING DIAGRAM
8.1 Indoor Unit
FG20/B-G(I)、FG25/B-G(I)、FG30/B-G(I)、FGR20/B-G(I)、FGR25/B-G(I)、FGR30/B-G(I)
FG40/B-G(I)、FGR40/B-G(I)
25
d
FG50/B(2)-G(I)、FG60/B(2)-G(I)、FGR50/B(2)-G(I)、FGR60/B(2)-G(I)、
FGR55/B-G(I)、FGR65/B-G(I)
The specification of power cord mentioned hereby is defined as the required specification when wiring
with BV single core cable(2~ 4pieces)under the cover of PVC pipe, and environment temperature
shall be at 40℃; Air switch shall be selected according to 40℃ temperature condition, and shall in
“ D” Type. If the installation condition on site changed, please consider the modification on the
required specification of Power cord and Air switch, according to the specification manual provided by
manufacture.
26
Duct Type Split Air Conditioners Technical Sales Guide
27
d
FGR20/C-M( I),
FGR25/C-M( I),
FGR30/C-M(I),
FGR40/C-M(I),
28
Duct Type Split Air Conditioners Technical Sales Guide
FGR20/B-G(O)、FGR25/B-G(O)、FGR30/B-G(O)
29
d
FG40/B-G(O)
FGR40/B-G(O)
30
Duct Type Split Air Conditioners Technical Sales Guide
FG55/B-G(O)、FG65/B-G(O)
FGR55/B-G(O)、FGR65/B-G(O)
31
d
The specification of power cord mentioned hereby is defined as the required specification when wiring
with BV single core cable(2~ 4pieces)under the cover of PVC pipe, and environment temperature
shall be at 40℃; Air switch shall be selected according to 40℃ temperature condition, and shall in
“ D” type. If the installation condition on site changed, please consider the modification on the
required specification of Power cord and Air switch, according to the specification manual provided by
manufacture.
32
Duct Type Split Air Conditioners Technical Sales Guide
FGR20/C-M( O);FGR25/C-M(O);
33
d
FGR30/C-M( O);
FGR40/C-M(O);
34
Duct Type Split Air Conditioners Technical Sales Guide
35
Gree Electric Appliance, Inc. of Zhuhai, founded in 1991, is the world's largest air conditioner
enterprise integrating R&D, manufacturing, marketing and services.
Technology Innovation and quality are always our priority. With efforts of thousands of Gree's
engineers, we own more than 3000 patents for our products.
With the installation of Gree commercial air conditioners in important projects at home and abroad
like Media Village for 2008 Beijing Olympic Games, Stadiums for 2010 World Cup in South Africa,
as well as India Telecom base station, Gree commercial air conditioners are ready to develop
steadily to every corner in the world, to present a more comfortable and harmonious working
environment and family atmosphere.