0% found this document useful (0 votes)
140 views36 pages

T1ducttype PDF

This document provides product information on GREE FG Series ducted air conditioners. It includes a models list, descriptions of nomenclature, features of outdoor and indoor units, product data, fan performance curves, clearance and dimension data, and wiring diagrams. The units have cooling capacities ranging from 5.7 to 18.5 tons and come in both heat pump and cooling only models. Features include corrosion resistant cabinets, protected compressors, low noise operation, and factory testing.

Uploaded by

Dung Vo Tan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views36 pages

T1ducttype PDF

This document provides product information on GREE FG Series ducted air conditioners. It includes a models list, descriptions of nomenclature, features of outdoor and indoor units, product data, fan performance curves, clearance and dimension data, and wiring diagrams. The units have cooling capacities ranging from 5.7 to 18.5 tons and come in both heat pump and cooling only models. Features include corrosion resistant cabinets, protected compressors, low noise operation, and factory testing.

Uploaded by

Dung Vo Tan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Guide

CONTENTS
1. MODELS LIST ................ .......................................................................................................... 2
2. NOMENCLATURE ................................................................................................................... 3

3. FEATURES .............................................................................................................................. 3

4. PRODUCT DATA .................................................................................................................... 5

5. FAN PERFORMANCE CURVES ............................................................................................... . 17

6. CLEARANCE DATA ............. .................................................................................................... 19

7. DIMENSION DATA ............................................................................................................. 21

8. WIRING DIAGRAM ................................................................................................................. 25

1 MODELS LIST
Nominal Capacity Model Power Supply
Model Name
Ton Refrigerant Ph, V, Hz
B-series C-series
FG20/B-G FG20/C-M
5.7 R22 3,380,50
FGR20/B-G FGR20/C-M
FG25/B-G FG25/C-M
7.1 R22 3,380,50
FGR25/B-G FGR25/C-M
FG30/B-G FG30/C-M
8.5 R22 3,380,50
FGR30/B-G FGR30/C-M
FG40/B-G FG40/C-M
11.4 R22 3,380,50
FGR40/B-G FGR40/C-M
FG55/B-G
15.6 R22 3,380,50
FGR55/B-G
FG65/B-G
18.5 R22 3,380,50
FGR65/B-G
FG50/B(2)-G
14.2 R22 3,380,50
FGR50/B(2)-G
FG60/B(2)-G
17.1 R22 3,380,50
FGR60/B(2)-G

1Ton =12000Btu/h = 3.517kW


Duct Type Split Air Conditioners Technical Sales Guide

2 NOMENCLATURE

FG / ( ) - ( )
1 2 3 4 5 6 7

No Description Options
1 Ducted type air conditioner
Heat pump type-R
2 Product type
Cooling only type-omitted
3 Cooling capacity Nominal cooling capacity (kW)
B-the second improvement;A-the first improvement
4 Design sequence C-depressed cost improvement
Omitted-the basic design
(2)-two outdoor units
5 Outdoor unit number
Omitted-one outdoor unit
M=3Ph,380V,50Hz;3Ph,400V,50Hz; 3Ph,420V,50Hz;
6 Power supply code K=1Ph,220~240V,50Hz ;1Ph,230~240V,50Hz
H=3Ph,380V,60Hz
(O)-Outdoor unit
7 Indoor and outdoor unit code (I)-Indoor unit
Omitted-whole unit

3 FEATURES

3.1 Description

GREE FG Series Ducted type Air-conditioning Units has combined the comfort, top grade from the
central air conditioners as well as the convenient installation and facility from the mini type of the split
air conditioners.
GREE FG Series Ducted type can offer the perfect combination of superior product quality、operating
efficiency and value for money. These units are available in vertical discharge configurations, as cool
only models. All capacities are rated according to the relevant National Standards. These units are
manufactured under strict quality control with full conformance to ISO 9001:2000 and ISO 14001
standards.
Indoor fan motor and motor are rotated by belt roller, so indoor outlet static pressure could be
adjusted within certain range.Outdoor unit air outlet is upward. The capacity range is 20kW to 60kW.
It could be sufficient to the different requirements from customers.
The FG Series Ducted Air-conditioning Units can be widely used in small supermarkets, chain stores,
hotels, restaurants, offices and meeting rooms etc. It's especially fit for the small commercial and
industrial application.
d

3.2 Features-Outdoor Units

Features Description
The coil is constructed of golden aluminum sheet and inner groove
Quality condenser coil
copper pipe
Coil protected Coils are protected from damage by a metal grill.
High / low pressure protection、Discharge high temperature protection、
Protected compressor Overload protection、Reverse (open) phase protection、Sensor
malfunction alarm
Cabinet is made of pre-painted steel. The pre-treated flat galvanized
steel provides a better paint to steel bond, which resists corrosion and
Resisting corrosion
rust creep . Special primer formulas ensure minimal fading when
exposed to sunlight.
Low operating sound level Low noise fan and low noise compressor with isolator
Low maintenance Quality compressor and motor are used
All units are factory tested prior to dispatch to verify system operation
Factory tested
and control functioning before shipment

3.3 Features-Indoor Units

Features Description
Condensing water tube and refrigerant tube are in same direction,
Flexible installation
it's better for installation
It adopts high static pressure design, so air is centralized handling in the
Long-distance duct air supply
indoor unit and implant long-distance duct air supply
The capacity range The capacity range is 20kW to 60kW
Convenient operation Simple controller and intelligent remote controller make unit more
convenient operation.
It can connect many supply-air outlet to the duct, so that it can make the
temperature and humidity of the whole room equality, meanwhile, it can
Good indoor air quality
lead in fresh air, makes well indoor unit air quality. All units are provided
with filters that are easily accessible from the rear of the unit.
The controls provide for compressor delay protection, Remote control
Microcomputer Control function ,temperature setting ,fan function,Sleep function,Memory
function, Self-diagnosis with alarm function.
Evaporator coils are constructed of inner groove copper tube and
Quality evaporator coil
hydrophilic aluminum sheet.
Low operating sound The fan motors are resilient mounted to minimize vibration and noise

4
Duct Type Split Air Conditioners Technical Sales Guide

4 PRODUCT DATA
4.1 Product Data at Rated Condition
FG(R) /B-G(I)
Indoor unit
20 25 30 40
Models
FG(R) /B-G(O)
Outdoor unit
20 25 30 40
Btu/h 68243 85304 102360 136490
Cooling
Nominal Capacity 20 25 30 40
At Rated ESP Btu/h 78479 95540 112601 146722
Heating
23 28 33 43
Power Supply V/Ph/Hz 380/3/50
Cooling 8.5 10.2 12.1 17.0
Power Consumption
Heating 6.8 8.7 10.1 14
Cooling A 15.8 18.9 21.8 31.9
Running Current
Heating A 13.5 16.8 18.3 27.3
Refrigerant Type R22
Refrigerant Charge 7.0 8.0 12.0 13.2
Power Supply V/Ph/Hz 380/3/50
Fan Type Centrifugal / Belt Drive
CFM 2354 2825 3237 4120
Air flow
4000 4800 5500 7000
Input Power W 1100 1100 1500 2200
Fan
Running Current A 2.8 3.0 3.6 4.5
0.36 0.36 0.52 0.52
Rated ESP
Pa 90 90 130 130
Fan Motor Protection Overload Protection
Sound Pressure Level dB(A) 54 54 57 58
Indoor

Material Inner Groove Copper Tube


Tube
Diameter 9.52 9.52 9.52 9.52
Coil
Material Aluminum
Fin
No.of Rows/FPI 3/16 3/16 4/16 4/16
Coil Area Sqm 0.59 0.66 0.66 0.81
Width 1500/1840 1700/1890
Dimensions
Depth 1000/1200 1100/1460
(Outline/Package)
Height 500/673 650/835
Weight(Net/Gross) 130/180 150/200 170/220 200/250
System Operation Control Wired Control with LED Display + Wireless Controller
Condensate Drainage(O.D) 25.4 25.4 25.4 25.4
Air Filter Standard Washable Synthetic
Power Supply V/Ph/Hz 380/3/50
Compressor Type Centrifugal / Belt Drive
Nominal Current A 12.5 13.7 17.6 25.6
Compressor
Vibration Isolator Rubber
Protection Device Auto Reset Thermal Overload
Fan Type/Drive Inner Groove Copper Tube
Fan Speed 660 730 730 730
Fan
Blade Material Plastic
Diameter 750 750 750 750
Tube Material Inner Groove Copper Tube
Coil Material Aluminum
Fan
No.of Rows/FPI 1/16 2/15 2/15 2/15
Coil Area Sqm 2.2 2.1 2.4 2.8
Dimensions Width 990/1162 1290/2020
(Outline/ Depth 880/980 880/1335
Package) Height 1772/2020 1772/980
Weight(Net/Gross) 200/230 230/260 250/280 300/330
_ _ _ _
Pipe Sizes Suction Inch 11
8 118 118 138
Liquid Inch
_
5 _
5 _
5 _
5
8 8 8 8

Note

1. The cooling capacity stated above is measured under following conditions :


Indoor Condition: 27℃(81℉)DB/19℃(66.6℉)WB;
Outdoor Condition: 35℃(95.4℉)DB
2. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual
operation due to environmental change.
3. The air flow stated above is measured under rated ESP.

5
d

FG(R) /B(2)-G(I) FG(R) /B-G(I)


Indoor unit
50 60 55 65
Models
FG(R) /B(2)-G(O) FG(R) /B-G(O)
Outdoor unit
50 60 55 65
Btu/h 170610 204730 187669 221790
Cooling
Nominal Capacity 50 60 55 65
At Rated ESP Btu/h 180844 218378 204730 238851
Heating
53 64 60 70
Power Supply V/Ph/Hz 380/3/50
Cooling 20.7 24.5 21.5 27.5
Power Consumption
Heating 17.7 20.5 19.5 22.8
Cooling A 38.9 46.0 40.4 51.6
Running Current
Heating A 34.5 39.9 38.0 44.3
Refrigerant Type R22
Refrigerant Charge 2×8 2×12 17 19
Power Supply V/Ph/Hz 380/3/50
Fan Type Centrifugal / Belt Drive
CFM 5297 6474 5297 6474
Air flow
9000 11000 9000 11000
Input Power W 3300 3300 3300 3300
Fan
Running Current A 6.0 8.4 6.0 8.4
0.64 0.64 0.64 0.64
Rated ESP
Pa 160 160 160 160
Fan Motor Protection Overload Protection
Sound Pressure Level dB(A) 60 62 60 62
Indoor

Material Inner Groove Copper Tube


Tube
Diameter 9.52 9.52 9.52 9.52
Coil
Material Aluminum
Fin
No.of Rows/FPI 4/16 4/16 4/16 4/16
Coil Area Sqm 0.96 1.22 0.96 1.22
Width 1900/2090 1900/2090 1900/2090 1900/2090
Dimensions
Depth 1100/1460 1100/1460 1100/1460 1100/1460
(Outline/Package)
Height 700/885 850/1040 700/885 850/1040
Weight(Net/Gross) 230/280 250/300 230/280 250/300
System Operation Control Wired Control with LED Display + Wireless Controller
Condensate Drainage(O.D) 25.4 25.4 25.4 25.4
Air Filter Standard Washable Synthetic
Power Supply V/Ph/Hz 380/3/50
Compressor Type Centrifugal / Belt Drive
Nominal Current A 2×13.7 2×17.6 29.6 37.9
Compressor
Vibration Isolator Rubber
Protection Device Auto Reset Thermal Overload
Fan Type/Drive Inner Groove Copper Tube
Fan Speed 730 730 730 730
Fan
Blade Material Plastic
Diameter 750 750 750 750
Tube Material Inner Groove Copper Tube
Coil Material Aluminum
Fan
No.of Rows/FPI 2/15 2/15 2/15 2/15
Coil Area Sqm 2×2.1 2×2.4 4.2 4.8
Dimensions Width 2×990/2×1162 2×990/2×1162 1980/2152 1980/2152
(Outline/ Depth 2×880/2×980 2×880/2×980 920/980 920/980
Package) Height 2×1772/2×2020 2×1772/2×2020 1760/1950 1760/1950
Weight(Net/Gross) 2×200/230 2×250/260 550/600 550/600
_
1 _
1 _ _
Pipe Sizes Suction Inch 2×18 2×18 158 158
_
5 _ _ _
Liquid Inch 2× 8 2× 5
8
7
8
7
8

Note

1.The cooling capacity stated above is measured under following conditions :


Indoor Condition: 27℃(81℉)DB/19℃(66.6℉)WB;
Outdoor Condition: 35℃(95.4℉)DB
2. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual
operation due to environmental change.
3.The air flow stated above is measured under rated ESP.

6
Duct Type Split Air Conditioners Technical Sales Guide

4.2Parameter and Specifications of the Duct Type Air Conditioner


FG(R) /C-M(I)
Indoor unit
20 25 30 40
Models
FG(R) /C-M(O)
Outdoor unit
20 25 30 40
Btu/h 66537 83598 100658 129675
Cooling
Nominal Capacity 19.5 24.5 29.5 38
At Rated ESP Btu/h 76773 93834 110895 139912
Heating
22.5 27.5 32.5 41
Power Supply V/Ph/Hz 380/3/50 380/3/50
Cooling 8.5 10.2 12.1 16
Power Consumption
Heating 6.8 8.7 10.1 13.5
Cooling A 15.8 18.9 21.8 30.5
Running Current
Heating A 13.5 16.8 18.3 25.7
Refrigerant Type R22
Refrigerant Charge 7.0 8.0 8.5 11
Power Supply V/Ph/Hz 380/3/50
Fan Type Centrifugal / Belt Drive
CFM 2354 2825 3237 4120
Air flow
4000 4800 5500 7000
Input Power W 1500 1500 1500 2200
Fan
Running Current A 2.6 2.8 3 4.2
0.36 0.44 0.52 0.60
Rated ESP
Pa 90 110 130 150
Fan Motor Protection Overload Protection
Sound Pressure Level dB(A) 54 54 57 58
Indoor

Material Inner Groove Copper Tube


Tube
Diameter 9.52 7.94 9.52 9.52
Coil
Material Aluminum
Fin
No.of Rows/FPI 2/16 3/16 4/16 3/16
Coil Area Sqm 0.66 0.63 0.66 0.86
Width 500 500 500 650
Dimensions
Depth 1500 1500 1500 1700
/Outline
Height 1000 1000 1000 1100
Width 673 673 673 835
Dimensions
Depth 1840 1840 1840 1890
/Package
Height 1200 1200 1200 1460
Weight(Net/Gross) 150/200 150/200 150/200 215/265
System Operation Control Wired Control with LED Display + Wireless Controller
Condensate Drainage(O.D) 25.4 25.4 25.4 25.4
Air Filter Standard Washable Synthetic
Power Supply V/Ph/Hz 380/3/50
Compressor Type Scroll
Nominal Current A 12.21 15.27 15.5 20.2
Compressor
Vibration Isolator Rubber
Protection Device Auto Reset Thermal Overload
Fan Type/Drive Axial/Direct Drive
Fan Speed 850 850 660 730
Fan
Blade Material Plastic
Outdoor Unit

Diameter 524 524 750 750


Tube Material Inner Groove Copper Tube
Coil Material Aluminum
Fan
No.of Rows/FPI 2/16 2/15 2/15 2/14
Coil Area Sqm 1.22 1.49 2.081 2.71
Dimensions Width 360 360 990 1290
/Outline Depth 1150 1150 880 880
Height 1350 1600 1772 1772
Dimensions Width 502 502 980 980
/Package Depth 1305 1305 1162 1370
Height 1460 1715 1950 1950
Weight(Net/Gross) 225/255 230/260 250/280 300/330
Pipe Sizes Suction Ø28 Ø35
Liquid Ø16 Ø16

Note
1. The design is according to GB/T 18836—2002 standard.
2. The parameter here might be changed by the factory, please refer to the name plate for the lasted one.
3. The Auxiliary Heater is optional.
4. this parameter table is only for the unit without auxiliary heater,which one with auxiliary heater please refer to the nameplate.

7
d

4.3 Working Range

Mode Range of Outdoor Temperature℃(℉)


Cooling 21~43℃(69.8~109.8℉)
Heating -5~24℃(23.0~75.6℉)

4.4 Cooling Performance

Model: FG(R)20/B-G FG(R)20/C-M


Outdoor Air Dry Bulb Temperature 77。F(25℃)
Indoor Air Wet Bulb Temperature 。F(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 18.9 64.4 13.5 45.9 21.9 74.8 13.3 45.4 22.6 77.0 11.3 38.5
24 75.2 19.1 65.0 15.4 52.5 22.1 75.6 14.2 48.3 22.8 77.8 12.5 42.7
4154 2445 70 0.28
27 80.6 19.4 66.3 15.1 51.5 22.3 76.2 14.9 50.9 23.0 78.5 13.8 47.0
31 87.6 19.7 67.3 15.7 53.7 22.6 77.0 15.5 52.9 23.2 79.3 15.1 51.4
23 73.4 18.6 63.5 13.3 45.2 21.6 73.7 13.1 44.8 22.2 75.9 11.1 37.9
24 75.2 18.8 64.1 15.2 51.7 21.8 74.4 14.0 47.6 22.5 76.7 12.3 42.1
4000 2354 90 0.36
27 80.6 19.2 65.4 14.9 50.7 22.0 75.1 14.7 50.2 22.7 77.4 13.6 46.3
31 87.6 19.4 66.3 15.5 52.9 22.2 75.8 15.3 52.1 22.9 78.1 14.9 50.7
23 73.4 18.3 62.5 13.1 44.6 21.3 72.6 12.9 44.1 21.9 74.8 10.9 37.3
24 75.2 18.5 63.1 14.9 50.9 21.5 73.3 13.7 46.9 22.1 75.5 12.2 41.5
3813 2244 110 0.44
27 80.6 18.9 64.4 14.6 50.0 21.7 74.0 14.5 49.4 22.3 76.2 13.4 45.6
31 87.6 19.1 65.3 15.3 52.1 21.9 74.7 15.1 51.4 22.6 76.9 14.6 49.9

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 17.2 58.6 12.2 41.7 19.9 68.0 12.1 41.3 20.5 70.0 10.2 34.9
24 75.2 17.3 59.1 14.0 47.7 20.1 68.7 12.9 43.9 20.7 70.7 11.4 38.8
4154 2445 70 0.28
27 80.6 17.7 60.3 13.7 46.8 20.3 69.3 13.6 46.3 20.9 71.4 12.5 42.7
31 87.6 17.9 61.1 14.3 48.8 20.5 69.9 14.1 48.1 21.1 72.0 13.7 46.7
23 73.4 16.9 57.7 12.0 41.1 19.6 67.0 11.9 40.7 20.2 69.0 10.1 34.4
24 75.2 17.1 58.2 13.8 47.0 19.8 67.6 12.7 43.3 20.4 69.7 11.2 38.2
4000 2354 90 0.36
27 80.6 17.4 59.4 13.5 46.1 20.0 68.2 13.4 45.6 20.6 70.3 12.3 42.1
31 87.6 17.6 60.2 14.1 48.0 20.2 68.9 13.9 47.4 20.8 71.0 13.5 46.1
23 73.4 16.7 56.8 11.9 40.5 19.3 66.0 11.7 40.1 19.9 67.9 9.9 33.9
24 75.2 16.8 57.3 13.6 46.3 19.5 66.6 12.5 42.6 20.1 68.6 11.0 37.7
3813 2244 110 0.44
27 80.6 17.1 58.5 13.3 45.4 19.7 67.2 13.2 44.9 20.3 69.3 12.1 41.4
31 87.6 17.4 59.3 13.9 47.3 19.9 67.9 13.7 46.7 20.5 69.9 13.3 45.4

8
Duct Type Split Air Conditioners Technical Sales Guide

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 15.3 52.3 10.9 37.3 17.8 60.8 10.8 36.9 18.3 62.6 9.2 31.2
24 75.2 15.5 52.8 12.5 42.6 18.0 61.4 11.5 39.3 18.5 63.2 10.2 34.7
4154 2445 70 0.28
27 80.6 15.8 53.9 12.3 41.8 18.3 61.9 12.1 41.3 18.7 63.8 11.2 38.2
31 87.6 16.0 54.6 12.8 43.6 18.3 62.5 12.6 43.0 18.9 64.4 12.2 41.8
23 73.4 15.1 51.6 10.8 36.7 17.5 59.9 10.7 36.4 18.1 61.6 9.0 30.8
24 75.2 15.3 52.0 12.3 42.0 17.7 60.5 11.3 38.7 18.3 62.3 10.0 34.2
4000 2354 90 0.36
27 80.6 15.6 53.1 12.1 41.2 18.0 61.0 11.9 40.7 18.4 62.8 11.0 37.6
31 87.6 15.8 53.8 12.6 42.9 18.1 61.6 12.4 42.3 18.6 63.5 12.1 41.2
23 73.4 14.9 50.8 10.6 36.2 17.3 59.0 10.5 35.8 17.8 60.7 8.9 30.3
24 75.2 15.0 51.3 12.1 41.4 17.5 59.6 11.2 38.1 18.0 61.3 9.9 33.7
3813 2244 110 0.44
27 80.6 15.3 52.3 11.9 40.6 17.7 60.1 11.8 40.1 18.1 61.9 10.9 37.1
31 87.6 15.5 53.0 12.4 42.3 17.8 60.7 12.2 41.7 18.3 62.5 11.9 40.6

Model: FG(R)25/B-G FG(R)25/C-M


Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 23.6 80.5 16.8 57.3 27.4 93.4 16.6 56.8 28.2 96.2 14.1 48.0
24 75.2 23.8 81.2 19.2 65.5 27.7 94.4 17.7 60.4 28.5 97.2 15.6 53.4
4985 2934 70 0.28
27 80.6 24.3 82.8 18.8 64.3 27.9 95.2 18.6 63.6 28.7 98.1 17.2 58.7
31 87.6 24.6 84.0 19.6 67.0 28.2 96.1 19.4 66.1 29.0 99.0 18.8 64.3
23 73.4 23.2 79.3 16.6 56.5 27.0 92.0 16.4 55.9 27.8 94.8 13.9 47.3
24 75.2 23.5 80.0 18.9 64.6 27.2 93.0 17.4 59.5 28.1 95.8 15.4 52.6
4800 2825 90 0.36
27 80.6 23.9 81.6 18.6 63.4 27.5 93.8 18.4 62.6 28.3 96.6 17.0 57.8
31 87.6 24.3 82.8 19.4 66.0 27.8 94.7 19.1 65.1 28.6 97.6 18.6 63.3
23 73.4 22.9 78.1 16.3 55.6 26.6 90.7 16.1 55.1 27.4 93.4 13.7 46.6
24 75.2 23.1 78.8 18.6 63.6 26.8 91.6 17.2 58.6 27.6 94.3 15.2 51.8
4575 2693 110 0.44
27 80.6 23.6 80.4 18.3 62.4 27.1 92.4 18.1 61.7 27.9 95.2 16.7 57.0
31 87.6 23.9 81.5 19.1 65.1 27.3 93.3 18.8 64.1 28.2 96.1 18.3 62.4

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 21.5 73.2 15.3 52.1 24.9 85.0 15.1 51.6 25.6 87.5 12.8 43.7
24 75.2 21.6 73.9 17.5 59.6 25.2 85.8 16.1 54.9 25.9 88.4 14.2 48.5
4985 2934 70 0.28
27 80.6 22.1 75.3 17.1 58.5 25.4 86.6 16.9 57.8 26.1 89.2 15.6 53.4
31 87.6 22.4 76.4 17.9 61.0 25.6 87.4 17.6 60.1 26.4 90.1 17.1 58.4
23 73.4 21.1 72.1 15.1 51.4 24.5 83.7 14.9 50.9 25.3 86.2 12.6 43.0
24 75.2 21.3 72.8 17.2 58.7 24.8 84.5 15.9 54.1 25.5 87.1 14.0 47.8
4800 2825 90 0.36
27 80.6 21.8 74.2 16.9 57.6 25.0 85.3 16.7 57.0 25.8 87.9 15.4 52.6
31 87.6 22.1 75.3 17.6 60.1 25.2 86.1 17.4 59.2 26.0 88.7 16.9 57.6
23 73.4 20.8 71.0 14.8 50.6 24.2 82.4 14.7 50.1 24.9 84.9 12.4 42.4
24 75.2 21.0 71.7 17.0 57.8 24.4 83.3 15.6 53.3 25.1 85.8 13.8 47.1
4575 2693 110 0.44
27 80.6 21.4 73.1 16.6 56.8 24.6 84.0 16.4 56.1 25.4 86.6 15.2 51.8
31 87.6 21.7 74.1 17.3 59.2 24.9 84.9 17.1 58.3 25.6 87.4 16.6 56.7

9
d

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 19.3 65.9 13.8 46.9 22.4 76.5 13.6 46.5 23.1 78.8 11.5 39.3
24 75.2 19.5 66.5 15.7 53.7 22.6 77.3 14.5 49.4 23.3 79.6 12.8 43.7
4985 2934 70 0.28
27 80.6 19.9 67.8 15.4 52.7 22.8 78.0 15.3 52.1 23.5 80.3 14.1 48.1
31 87.6 20.2 68.8 16.1 54.9 23.1 78.7 15.9 54.1 23.8 81.1 15.4 52.6
23 73.4 19.0 64.9 13.6 46.3 22.1 75.4 13.4 45.8 22.7 77.6 11.4 38.7
24 75.2 19.2 65.5 15.5 52.9 22.3 76.1 14.3 48.7 23.0 78.4 12.6 43.0
4800 2825 90 0.36
27 80.6 19.6 66.8 15.2 51.9 22.5 76.8 15.0 51.3 23.2 79.1 13.9 47.4
31 87.6 19.9 67.8 15.8 54.1 22.7 77.6 15.6 53.3 23.4 79.9 15.2 51.8
23 73.4 18.7 64.0 13.4 45.6 21.8 74.2 13.2 45.1 22.4 76.4 11.2 38.2
24 75.2 18.9 64.5 15.3 52.1 22.0 75.0 14.1 48.0 22.6 77.2 12.4 42.4
4575 2693 110 0.44
27 80.6 19.3 65.8 15.0 51.1 22.2 75.6 14.8 50.5 22.8 77.9 13.7 46.6
31 87.6 19.6 66.7 15.6 53.3 22.4 76.4 15.4 52.5 23.1 78.7 15.0 51.1

Model: FG(R)30/B-G FG(R)30/C-M


Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 28.3 96.6 20.2 68.8 32.9 112.2 20.0 68.1 33.8 115.5 16.9 57.7
24 75.2 28.6 97.5 23.1 78.7 33.2 113.3 21.2 72.5 34.2 116.7 18.8 64.1
5712 3362 110 0.44
27 80.6 29.1 99.5 22.6 77.2 33.5 114.3 22.4 76.3 34.5 117.8 20.7 70.5
31 87.6 29.6 100.8 23.6 80.5 33.8 115.4 23.3 79.3 34.8 118.9 22.6 77.1
23 73.4 27.9 95.2 19.9 67.8 32.4 110.5 19.7 67.1 33.3 113.8 16.6 56.8
24 75.2 28.2 96.1 22.7 77.5 32.7 111.6 20.9 71.4 33.7 115.0 18.5 63.1
5500 3237 130 0.52
27 80.6 28.7 98.0 22.3 76.1 33.0 112.6 22.0 75.2 34.0 116.0 20.3 69.4
31 87.6 29.1 99.3 23.2 79.3 33.3 113.7 22.9 78.2 34.3 117.1 22.3 76.0
23 73.4 27.5 93.8 19.6 66.8 31.9 108.8 19.4 66.1 32.8 112.1 16.4 55.9
24 75.2 27.7 94.6 22.4 76.4 32.2 109.9 20.6 70.3 33.2 113.2 18.2 62.2
5243 3086 150 0.60
27 80.6 28.3 96.5 22.0 74.9 32.5 110.9 21.7 74.1 33.5 114.3 20.0 68.4
31 87.6 28.7 97.9 22.9 78.1 32.8 112.0 22.6 77.0 33.8 115.4 21.9 74.9

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 25.8 87.9 18.3 62.6 29.9 102.0 18.2 62.0 30.8 105.0 15.4 52.4
24 75.2 26.0 88.7 21.0 71.6 30.2 103.0 19.3 65.9 31.1 106.1 17.1 58.3
4985 2934 70 0.28
27 80.6 26.5 90.4 20.6 70.2 30.5 103.9 20.3 69.4 31.4 107.1 18.8 64.1
31 87.6 26.9 91.7 21.4 73.2 30.8 105.0 21.1 72.2 31.7 108.1 20.6 70.1
23 73.4 25.4 86.6 18.1 61.7 29.5 100.5 17.9 61.1 30.3 103.5 15.1 51.7
24 75.2 25.6 87.4 20.7 70.5 29.7 101.5 19.0 64.9 30.6 104.5 16.8 57.4
4800 2825 90 0.36
27 80.6 26.1 89.1 20.3 69.2 30.0 102.4 20.0 68.4 30.9 105.5 18.5 63.1
31 87.6 26.5 90.3 21.1 72.1 30.3 103.4 20.8 71.1 31.2 106.5 20.3 69.1
23 73.4 25.0 85.3 17.8 60.7 29.0 99.0 17.6 60.1 29.9 101.9 14.9 50.9
24 75.2 25.2 86.0 20.4 69.4 29.3 100.0 18.7 64.0 30.2 103.0 16.6 56.5
4575 2693 110 0.44
27 80.6 25.7 87.8 20.0 68.1 29.6 100.9 19.7 67.4 30.5 103.9 18.2 62.2
31 87.6 26.1 89.0 20.8 71.0 29.9 101.9 20.5 70.0 30.7 104.9 20.0 68.1

10
Duct Type Split Air Conditioners Technical Sales Guide

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 23.1 78.9 16.5 56.2 26.9 91.6 16.3 55.7 27.7 94.4 13.8 47.1
24 75.2 23.3 79.7 18.8 64.3 27.1 92.6 17.4 59.2 27.9 95.3 15.3 52.3
5712 3362 110 0.44
27 80.6 23.8 81.3 18.5 63.1 27.4 93.4 18.3 62.4 28.2 96.2 16.9 57.6
31 87.6 24.1 82.4 19.3 65.7 27.6 94.3 19.0 64.8 28.5 97.1 18.5 63.0
23 73.4 22.8 77.8 16.2 55.4 26.5 90.3 16.1 54.9 27.2 93.0 13.6 46.4
24 75.2 23.0 78.5 18.6 63.3 26.7 91.2 17.1 58.3 27.5 93.9 15.1 51.6
5500 3237 130 0.52
27 80.6 23.5 80.1 18.2 62.1 27.0 92.0 18.0 61.4 27.8 94.8 16.6 56.7
31 87.6 23.8 81.2 19.0 64.8 27.2 92.9 18.7 63.9 28.0 95.7 18.2 62.1
23 73.4 22.5 76.6 16.0 54.6 26.1 88.9 15.8 54.0 26.8 91.6 13.4 45.7
24 75.2 22.7 77.3 18.3 62.4 26.3 89.8 16.8 57.5 27.1 92.5 14.9 50.8
5243 3086 150 0.60
27 80.6 23.1 78.9 17.9 61.2 26.6 90.6 17.7 60.5 27.4 93.4 16.4 55.9
31 87.6 23.4 80.0 18.7 63.8 26.8 91.5 18.4 62.9 27.6 94.3 17.9 61.2

Model: FG(R)40/B-G FG(R)40/C-M


Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 37.8 128.9 26.9 91.8 43.8 149.6 26.6 90.9 45.2 154.1 22.5 76.9
24 75.2 38.1 130.1 30.8 105.0 44.3 151.1 28.3 96.7 45.6 155.6 25.0 85.4
7270 4279 110 0.44
27 80.6 38.9 132.7 30.2 103.0 44.7 152.5 29.8 101.8 46.0 157.1 27.6 94.0
31 87.6 39.4 134.5 31.5 107.3 45.1 154.0 31.0 105.8 46.5 158.6 30.2 102.9
23 73.4 37.2 127.0 26.5 90.5 43.2 147.4 26.2 89.6 44.5 151.8 22.2 75.8
24 75.2 37.6 128.1 30.3 103.4 43.6 148.9 27.9 95.3 44.9 153.3 24.7 84.2
7000 4120 130 0.52
27 80.6 38.3 130.7 29.7 101.5 44.0 150.2 29.4 100.3 45.4 154.8 27.1 92.6
31 87.6 38.8 132.5 31.0 105.8 44.5 151.7 30.6 104.3 45.8 156.2 29.7 101.4
23 73.4 36.7 125.1 26.1 89.1 42.5 145.2 25.9 88.2 43.8 149.5 21.9 74.6
24 75.2 37.0 126.2 29.9 101.9 43.0 146.6 27.5 93.8 44.3 151.0 24.3 82.9
6672 3927 150 0.60
27 80.6 37.7 128.7 29.3 99.9 43.3 147.9 29.0 98.8 44.7 152.4 26.7 91.2
31 87.6 38.3 130.5 30.5 104.2 43.8 149.4 30.1 102.7 45.1 153.9 29.3 99.8

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 34.3 117.1 24.5 83.4 39.8 136.0 24.2 82.6 41.0 140.0 20.5 69.9
24 75.2 34.6 118.2 28.0 95.4 40.2 137.3 25.8 87.9 41.5 141.4 22.8 77.7
7270 4279 110 0.44
27 80.6 35.3 120.6 27.4 93.6 40.6 138.5 27.1 92.5 41.8 142.7 25.0 85.4
31 87.6 35.8 122.2 28.6 97.5 41.0 139.9 28.2 96.2 42.2 144.1 27.4 93.5
23 73.4 33.8 115.4 24.1 82.2 39.3 133.9 23.9 81.4 40.4 137.9 20.2 68.9
24 75.2 34.1 116.4 27.5 94.0 39.7 135.3 25.4 86.6 40.8 139.4 22.4 76.5
7000 4120 130 0.52
27 80.6 34.8 118.8 27.0 92.2 40.0 136.5 26.7 91.2 41.2 140.6 24.7 84.2
31 87.6 35.3 120.4 28.2 96.1 40.4 137.9 27.8 94.8 41.6 142.0 27.0 92.1
23 73.4 33.3 113.7 23.7 81.0 38.7 131.9 23.5 80.2 39.8 135.9 19.9 67.8
24 75.2 33.6 114.7 27.1 92.6 39.1 133.3 25.0 85.3 40.2 137.3 22.1 75.4
6672 3927 150 0.60
27 80.6 34.3 117.0 26.6 90.8 39.4 134.5 26.3 89.8 40.6 138.5 24.3 82.9
31 87.6 34.8 118.6 27.7 94.7 39.8 135.8 27.4 93.3 41.0 139.9 26.6 90.7

11
d

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 30.9 105.5 22.0 75.1 35.9 122.4 21.8 74.4 36.9 126.1 18.4 62.9
24 75.2 31.2 106.4 25.2 85.9 36.2 123.6 23.2 79.1 37.3 127.4 20.5 69.9
7270 4279 110 0.44
27 80.6 31.8 108.6 24.7 84.3 36.9 124.7 24.4 83.3 37.7 128.5 22.5 76.9
31 87.6 32.3 110.1 25.7 87.8 36.9 126.0 25.4 86.6 38.0 129.8 24.7 84.2
23 73.4 30.5 103.9 21.7 74.0 35.3 120.6 21.5 73.3 36.4 124.2 18.2 62.0
24 75.2 30.7 104.8 24.8 84.6 35.7 121.8 22.8 77.9 36.8 125.5 20.2 68.9
7000 4120 130 0.52
27 80.6 31.3 106.9 24.3 83.0 36.4 122.9 24.1 82.1 37.1 126.6 22.2 75.8
31 87.6 31.8 108.4 25.4 86.5 36.4 124.1 25.0 85.3 37.5 127.8 24.3 82.9
23 73.4 30.0 102.3 21.4 72.9 34.8 118.8 21.2 72.2 35.9 122.3 17.9 61.1
24 75.2 30.3 103.3 24.4 83.3 35.2 120.0 22.5 76.8 36.2 123.6 19.9 67.8
6672 3927 150 0.60
27 80.6 30.9 105.3 24.0 81.8 35.9 121.1 23.7 80.8 36.6 124.7 21.9 74.6
31 87.6 31.3 106.8 25.0 85.2 35.8 122.3 24.6 84.0 36.9 125.9 23.9 81.7

Model: FG(R)55/B-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 51.9 177.2 37.0 126.2 60.3 205.7 36.6 125.0 62.1 211.8 31.0 105.7
24 75.2 52.4 178.8 42.3 144.3 60.9 207.8 39.0 132.9 62.7 214.0 34.4 117.5
9348 5502 140 0.56
27 80.6 53.5 182.4 41.5 141.6 61.4 209.6 41.0 140.0 63.3 215.9 37.9 129.2
31 87.6 54.2 184.9 43.3 147.6 62.0 211.7 42.6 145.5 63.9 218.0 41.5 141.5
23 73.4 51.2 174.6 36.4 124.4 59.4 202.6 36.1 123.1 61.2 208.7 30.5 104.2
24 75.2 51.6 176.2 41.7 142.2 60.0 204.7 38.4 131.0 61.8 210.8 33.9 115.7
9000 5297 160 0.64
27 80.6 52.7 179.7 40.9 139.5 60.5 206.5 40.4 137.9 62.4 212.8 37.3 127.3
31 87.6 53.4 182.2 42.6 145.4 61.1 208.5 42.0 143.4 63.0 214.8 40.8 139.4
23 73.4 50.4 172.0 35.9 122.5 58.5 199.6 35.5 121.3 60.2 205.5 30.1 102.6
24 75.2 50.9 173.5 41.0 140.0 59.1 201.6 37.8 129.0 60.9 207.7 33.4 114.0
8579 5049 180 0.72
27 80.6 51.9 177.0 40.3 137.4 59.6 203.4 39.8 135.8 61.4 209.6 36.8 125.4
31 87.6 52.6 179.5 42.0 143.2 60.2 205.4 41.4 141.2 62.0 211.6 40.2 137.3

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 47.2 161.0 33.6 114.7 54.8 186.9 33.3 113.6 56.4 192.5 28.2 96.1
24 75.2 47.6 162.5 38.4 131.1 55.3 188.8 35.4 120.8 57.0 194.5 31.3 106.8
9348 5502 140 0.56
27 80.6 48.6 165.8 37.7 128.7 55.8 190.5 37.3 127.2 57.5 196.2 34.4 117.5
31 87.6 49.3 168.1 39.3 134.1 56.4 192.4 38.8 132.2 58.1 198.1 37.7 128.5
23 73.4 46.5 158.6 33.1 113.0 54.0 184.2 32.8 111.9 55.6 189.6 27.7 94.7
24 75.2 46.9 160.1 37.9 129.2 54.5 186.0 34.9 119.0 56.1 191.6 30.8 105.2
9000 5297 160 0.64
27 80.6 47.9 163.3 37.1 126.8 55.0 187.7 36.7 125.3 56.7 193.3 33.9 115.7
31 87.6 48.5 165.6 38.7 132.1 55.5 189.5 38.2 130.3 57.2 195.2 37.1 126.6
23 73.4 45.8 156.3 32.6 111.3 53.2 181.4 32.3 110.2 54.7 186.8 27.3 93.2
24 75.2 46.2 157.7 37.3 127.3 53.7 183.2 34.4 117.2 55.3 188.7 30.4 103.6
8579 5049 180 0.72
27 80.6 47.1 160.9 36.6 124.9 54.2 184.8 36.2 123.4 55.8 190.4 33.4 114.0
31 87.6 47.8 163.1 38.1 130.1 54.7 186.7 37.6 128.3 56.4 192.3 36.6 124.7

12
Duct Type Split Air Conditioners Technical Sales Guide

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 42.5 144.9 30.3 103.2 49.3 168.2 30.0 102.2 50.8 173.2 25.3 86.5
24 75.2 42.9 146.2 34.6 118.0 49.8 169.9 31.9 108.7 51.3 175.0 28.2 96.1
9348 5502 140 0.56
27 80.6 43.7 149.2 33.9 115.8 50.2 171.4 33.6 114.5 51.8 176.6 31.0 105.7
31 87.6 44.3 151.3 35.4 120.7 50.7 173.1 34.9 119.0 52.3 178.3 33.9 115.7
23 73.4 41.8 142.8 29.8 101.7 48.6 165.7 29.5 100.7 50.0 170.7 25.0 85.2
24 75.2 42.2 144.1 34.1 116.3 49.1 167.4 31.4 107.1 50.5 172.4 27.7 94.7
9000 5297 160 0.64
27 80.6 43.1 147.0 33.4 114.1 49.5 168.9 33.1 112.8 51.0 174.0 30.5 104.1
31 87.6 43.7 149.0 34.9 118.9 50.0 170.6 34.4 117.3 51.5 175.7 33.4 114.0
23 73.4 41.2 140.6 29.4 100.2 47.8 163.3 29.1 99.2 49.3 168.1 24.6 83.9
24 75.2 41.6 141.9 33.6 114.5 48.3 164.9 30.9 105.5 49.8 169.8 27.3 93.2
8579 5049 180 0.72
27 80.6 42.4 144.8 32.9 112.4 48.8 166.4 32.6 111.1 50.2 171.4 30.1 102.6
31 87.6 43.0 146.8 34.3 117.1 49.2 168.0 33.8 115.5 50.7 173.1 32.9 112.3

Model: FG(R)65/B-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 56.3 192.2 40.1 136.9 65.4 223.1 39.7 135.6 67.3 229.7 33.6 114.7
24 75.2 56.8 194.0 45.9 156.5 66.0 225.4 42.3 144.2 68.0 232.1 37.3 127.4
9348 5502 140 0.56
27 80.6 58.0 197.8 45.0 153.6 72.6 227.4 44.5 151.8 68.7 234.2 41.1 140.2
31 87.6 58.8 200.6 46.9 160.1 67.3 229.6 46.3 157.8 69.3 236.5 45.0 153.4
23 73.4 55.5 189.4 39.5 134.9 64.4 219.8 39.1 133.6 66.3 226.4 33.1 113.0
24 75.2 56.0 191.1 45.2 154.2 65.1 222.0 41.6 142.1 67.0 228.7 36.8 125.5
9000 5297 160 0.64
27 80.6 57.1 194.9 44.3 151.3 71.5 224.0 43.8 149.6 67.6 230.8 40.5 138.1
31 87.6 57.9 197.6 46.2 157.7 66.3 226.2 45.6 155.5 68.3 233.0 44.3 151.2
23 73.4 54.7 186.5 38.9 132.9 63.5 216.5 38.6 131.6 65.3 223.0 32.6 111.3
24 75.2 55.2 188.2 44.5 151.9 64.1 218.7 41.0 139.9 66.0 225.3 36.2 123.7
8579 5049 180 0.72
27 80.6 56.3 192.0 43.7 149.0 70.4 220.6 43.2 147.3 66.6 227.3 39.9 136.1
31 87.6 57.1 194.7 45.5 155.3 65.3 222.8 44.9 153.2 67.3 229.5 43.6 148.9

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 55.8 190.3 39.7 135.6 64.7 220.9 39.3 134.2 66.7 227.5 33.3 113.6
24 75.2 56.3 192.0 45.4 155.0 65.4 223.1 41.8 142.8 67.4 229.8 37.0 126.2
9348 5502 140 0.56
27 80.6 57.4 195.9 44.6 152.0 66.0 225.1 44.1 150.3 68.0 231.9 40.7 138.8
31 87.6 58.2 198.6 46.5 158.5 66.6 227.3 45.8 156.3 68.6 234.2 44.5 151.9
23 73.4 55.0 187.5 39.1 133.6 63.8 217.6 38.8 132.2 65.7 224.1 32.8 111.9
24 75.2 55.5 189.2 44.7 152.7 64.4 219.8 41.2 140.6 66.4 226.4 36.4 124.3
9000 5297 160 0.64
27 80.6 56.6 193.0 43.9 149.8 65.0 221.8 43.4 148.1 67.0 228.5 40.1 136.8
31 87.6 57.3 195.7 45.8 156.1 65.6 224.0 45.1 154.0 67.6 230.7 43.9 149.7
23 73.4 54.1 184.7 38.6 131.6 62.8 214.4 38.2 130.3 64.7 220.7 32.3 110.2
24 75.2 54.6 186.4 44.1 150.4 63.5 216.5 40.6 138.5 65.4 223.0 35.9 122.4
8579 5049 180 0.72
27 80.6 55.7 190.1 43.2 147.6 64.0 218.5 42.8 145.9 66.0 225.1 39.5 134.7
31 87.6 56.5 192.7 45.1 153.8 64.7 220.6 44.4 151.7 66.6 227.2 43.2 147.4

13
d

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 38.6 131.7 27.5 93.8 44.8 152.9 27.2 92.9 46.1 157.4 23.0 78.6
24 75.2 39.0 132.9 31.4 107.3 45.3 154.4 29.0 98.8 46.6 159.1 25.6 87.3
9348 5502 140 0.56
27 80.6 39.7 135.6 30.8 105.2 45.7 155.8 30.5 104.0 47.0 160.5 28.2 96.1
31 87.6 40.3 137.5 32.2 109.7 46.1 157.3 31.7 108.2 47.5 162.1 30.8 105.1
23 73.4 38.0 129.8 27.1 92.4 44.1 150.6 26.8 91.5 45.5 155.1 22.7 77.4
24 75.2 38.4 131.0 31.0 105.7 44.6 152.1 28.5 97.3 45.9 156.7 25.2 86.0
9000 5297 160 0.64
27 80.6 39.1 133.6 30.4 103.7 45.0 153.5 30.0 102.5 46.4 158.2 27.7 94.7
31 87.6 39.7 135.4 31.7 108.1 45.4 155.0 31.2 106.6 46.8 159.7 30.4 103.6
23 73.4 37.5 127.8 26.7 91.1 43.5 148.4 26.4 90.1 44.8 152.8 22.4 76.3
24 75.2 37.8 129.0 30.5 104.1 43.9 149.9 28.1 95.9 45.2 154.4 24.8 84.7
8579 5049 180 0.72
27 80.6 38.6 131.6 29.9 102.1 44.3 151.2 29.6 101.0 45.7 155.8 27.3 93.2
31 87.6 39.1 133.4 31.2 106.5 44.8 152.7 30.8 105.0 46.1 157.3 29.9 102.0

Model: FG(R)50/B(2)-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 47.2 161.1 33.6 114.7 54.8 187.0 33.3 113.6 56.4 192.5 28.2 96.1
24 75.2 47.6 162.5 38.4 131.2 55.3 188.8 35.4 120.8 57.0 194.5 31.3 106.8
9348 5502 140 0.56
27 80.6 48.6 165.8 37.7 128.7 55.8 190.5 37.3 127.2 57.5 196.3 34.4 117.5
31 87.6 49.3 168.1 39.3 134.1 56.4 192.4 38.8 132.3 58.1 198.2 37.7 128.6
23 73.4 46.5 158.7 33.1 113.0 54.0 184.2 32.8 111.9 55.6 189.7 27.8 94.7
24 75.2 46.9 160.1 37.9 129.2 54.5 186.0 34.9 119.0 56.2 191.6 30.8 105.2
9000 5297 160 0.64
27 80.6 47.9 163.3 37.2 126.8 55.0 187.7 36.7 125.3 56.7 193.4 33.9 115.7
31 87.6 48.5 165.6 38.7 132.2 55.6 189.6 38.2 130.3 57.2 195.2 37.1 126.7
23 73.4 45.8 156.3 32.6 111.3 53.2 181.4 32.3 110.2 54.8 186.8 27.3 93.3
24 75.2 46.2 157.7 37.3 127.3 53.7 183.3 34.4 117.2 55.3 188.7 30.4 103.6
8579 5049 180 0.72
27 80.6 47.2 160.9 36.6 124.9 54.2 184.9 36.2 123.5 55.8 190.5 33.4 114.0
31 87.6 47.8 163.1 38.2 130.2 54.7 186.7 37.6 128.3 56.4 192.3 36.6 124.8

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 42.9 146.4 30.6 104.3 49.8 169.9 30.3 103.2 51.3 175.0 25.6 87.3
24 75.2 43.3 147.7 34.9 119.2 50.3 171.6 32.2 109.8 51.8 176.8 28.4 97.1
9348 5502 140 0.56
27 80.6 44.2 150.7 34.3 117.0 50.8 173.2 33.9 115.6 52.3 178.4 31.3 106.8
31 87.6 44.8 152.8 35.7 121.9 51.3 174.9 35.2 120.2 52.8 180.1 34.3 116.9
23 73.4 42.3 144.2 30.1 102.7 49.1 167.4 29.8 101.7 50.5 172.4 25.2 86.1
24 75.2 42.7 145.5 34.4 117.4 49.6 169.1 31.7 108.2 51.0 174.2 28.0 95.6
9000 5297 160 0.64
27 80.6 43.5 148.5 33.8 115.2 50.0 170.6 33.4 113.9 51.5 175.8 30.8 105.2
31 87.6 44.1 150.5 35.2 120.1 50.5 172.3 34.7 118.4 52.0 177.5 33.7 115.1
23 73.4 41.6 142.1 29.7 101.2 48.3 164.9 29.4 100.2 49.8 169.8 24.8 84.8
24 75.2 42.0 143.4 33.9 115.7 48.8 166.6 31.2 106.6 50.3 171.6 27.6 94.2
8579 5049 180 0.72
27 80.6 42.9 146.2 33.3 113.5 49.3 168.0 32.9 112.2 50.7 173.1 30.4 103.6
31 87.6 43.5 148.3 34.7 118.3 49.7 169.7 34.2 116.7 51.2 174.8 33.2 113.4

14
Duct Type Split Air Conditioners Technical Sales Guide

Outdoor Air Dry Bulb Temperature 110℉(43℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 38.6 131.7 27.5 93.8 44.8 152.9 27.2 92.9 46.1 157.4 23.0 78.6
24 75.2 39.0 132.9 31.4 107.3 45.3 154.4 29.0 98.8 46.6 159.1 25.6 87.3
9348 5502 140 0.56
27 80.6 39.7 135.6 30.8 105.2 45.7 155.8 30.5 104.0 47.0 160.5 28.2 96.1
31 87.6 40.3 137.5 32.2 109.7 46.1 157.3 31.7 108.2 47.5 162.1 30.8 105.1
23 73.4 38.0 129.8 27.1 92.4 44.1 150.6 26.8 91.5 45.5 155.1 22.7 77.4
24 75.2 38.4 131.0 31.0 105.7 44.6 152.1 28.5 97.3 45.9 156.7 25.2 86.0
9000 5297 160 0.64
27 80.6 39.1 133.6 30.4 103.7 45.0 153.5 30.0 102.5 46.4 158.2 27.7 94.7
31 87.6 39.7 135.4 31.7 108.1 45.4 155.0 31.2 106.6 46.8 159.7 30.4 103.6
23 73.4 37.5 127.8 26.7 91.1 43.5 148.4 26.4 90.1 44.8 152.8 22.4 76.3
24 75.2 37.8 129.0 30.5 104.1 43.9 149.9 28.1 95.9 45.2 154.4 24.8 84.7
8579 5049 180 0.72
27 80.6 38.6 131.6 29.9 102.1 44.3 151.2 29.6 101.0 45.7 155.8 27.3 93.2
31 87.6 39.1 133.4 31.2 106.5 44.8 152.7 30.8 105.0 46.1 157.3 29.9 102.0

Model: FG(R)60/B(2)-G
Outdoor Air Dry Bulb Temperature 77℉(25℃)
Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 57.2 195.1 40.7 139.0 66.4 226.5 40.3 137.6 68.4 233.2 34.1 116.4
24 75.2 57.7 196.9 46.6 158.9 67.1 228.8 42.9 146.4 69.1 235.6 37.9 129.4
11425 6724 140 0.56
27 80.6 58.9 200.9 45.7 155.9 67.0 230.8 45.2 154.1 69.7 237.8 41.7 142.3
31 87.6 59.7 203.6 47.6 162.5 68.3 233.1 47.0 160.2 70.4 240.1 45.7 155.8
23 73.4 56.3 192.2 40.1 137.0 65.4 223.1 39.7 135.6 67.3 229.8 33.6 114.7
24 75.2 56.9 194.0 45.9 156.6 66.1 225.4 42.3 144.2 68.0 232.2 37.4 127.5
11000 6474 160 0.64
27 80.6 58.0 197.9 45.0 153.6 66.0 227.4 44.5 151.9 68.7 234.3 41.1 140.2
31 87.6 58.8 200.6 46.9 160.1 67.3 229.7 46.3 157.9 69.3 236.5 45.0 153.5
23 73.4 55.5 189.4 39.5 134.9 64.4 219.8 39.1 133.6 66.3 226.3 33.1 113.0
24 75.2 56.0 191.1 45.2 154.2 65.1 222.0 41.6 142.0 67.0 228.7 36.8 125.5
10485 6171 180 0.72
27 80.6 57.1 194.9 44.3 151.3 65.0 224.0 43.8 149.6 67.6 230.8 40.5 138.1
31 87.6 57.9 197.6 46.2 157.7 66.3 226.2 45.6 155.5 68.3 233.0 44.3 151.2

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 51.5 175.6 36.7 125.1 59.8 203.9 36.3 123.9 61.5 210.0 30.7 104.8
24 75.2 51.9 177.2 41.9 143.0 60.4 205.9 38.6 131.8 62.2 212.1 34.1 116.4
11425 6724 140 0.56
27 80.6 53.0 180.8 41.1 140.3 60.9 207.8 40.7 138.7 62.7 214.1 37.5 128.1
31 87.6 53.7 183.3 42.9 146.3 61.5 209.8 42.3 144.2 63.3 216.1 41.1 140.2
23 73.4 50.7 173.1 36.1 123.3 58.9 200.9 35.8 122.0 60.6 206.8 30.3 103.3
24 75.2 51.2 174.6 41.3 140.9 59.5 202.9 38.0 129.8 61.2 209.0 33.6 114.7
11000 6474 160 0.64
27 80.6 52.2 178.1 40.5 138.3 60.0 204.7 40.1 136.7 61.8 210.9 37.0 126.2
31 87.6 52.9 180.6 42.2 144.1 60.6 206.7 41.6 142.1 62.4 212.9 40.5 138.1
23 73.4 50.0 170.5 35.6 121.4 58.0 197.9 35.2 120.2 59.7 203.7 29.8 101.7
24 75.2 50.4 172.0 40.7 138.8 58.6 199.9 37.5 127.9 60.3 205.8 33.1 113.0
10485 6171 180 0.72
27 80.6 51.4 175.5 39.9 136.2 59.1 201.6 39.5 134.6 60.9 207.7 36.4 124.3
31 87.6 52.1 177.9 41.6 142.0 59.7 203.6 41.0 140.0 61.5 209.7 39.9 136.1

15
d

Outdoor Air Dry Bulb Temperature 95℉(35℃)


Indoor Air Wet Bulb Temperature ℉(℃)
Air Flow Entering
ESP 62℉(17℃) 67℉(19℃) 72℉(22℃)
Rate Air DBT
Total Sensible Total Sensible Total Sensible
Capacity Capacity Capacity Capacity Capacity Capacity
℃ ℉ Mbh Mbh Mbh Mbh Mbh Mbh
23 73.4 46.3 158.1 33.0 112.6 53.8 183.5 32.7 111.5 55.4 188.9 27.6 94.3
24 75.2 46.7 159.5 37.7 128.7 54.3 185.3 34.7 118.6 55.9 190.9 30.7 104.8
11425 6724 140 0.56
27 80.6 47.7 162.7 37.0 126.3 54.8 187.0 36.6 124.9 56.5 192.6 33.8 115.3
31 87.6 48.3 165.0 38.6 131.6 55.3 188.8 38.0 129.8 57.0 194.5 37.0 126.2
23 73.4 45.6 155.7 32.5 110.9 53.0 180.8 32.2 109.8 54.6 186.1 27.2 92.9
24 75.2 46.1 157.1 37.2 126.8 53.5 182.6 34.2 116.8 55.1 188.0 30.3 103.2
11000 6474 160 0.64
27 80.6 47.0 160.3 36.5 124.4 54.0 184.2 36.1 123.0 55.6 189.8 33.3 113.6
31 87.6 47.6 162.5 38.0 129.7 54.5 186.0 37.5 127.9 56.2 191.6 36.4 124.3
23 73.4 45.0 153.4 32.0 109.3 52.2 178.0 31.7 108.2 53.7 183.3 26.8 91.5
24 75.2 45.4 154.8 36.6 124.9 52.7 179.8 33.7 115.1 54.3 185.2 29.8 101.7
10485 6171 180 0.72
27 80.6 46.3 157.9 35.9 122.6 53.2 181.4 35.5 121.2 54.8 186.9 32.8 111.9
31 87.6 46.9 160.1 37.4 127.7 53.7 183.2 36.9 126.0 55.3 188.7 35.9 122.4

4.5 Electrical Data


Max. Min.
Compressor Fan Motor Fuse Breaker Size Disconnect Size
(Indoor/Outoor) (Indoor/Outoor)

Model Condenser Supply


Power Supply Qty. RLA LRA Fan Blower
Motors Motor Amperes Amperes

Ph, V, Hz Each Each FLA Each FLA Each


FG(R)20/B-G 3, 380, 50 1 16.4 95 1.5 2.7 15/35 3.4/22
FG(R)25/B-G 3,380,50 1 19.2 110 2.5 2.7 15/45 3.4/26.5
FG(R)30/B-G 3,380,50 1 22.1 110 2.5 3.6 15/50 4.5/30.1
FG(R)40/B-G 3,380, 50 1 26.9 168 2.5 4.98 15/60 6.2/36.1
FG(R)50/B(2)-G 3,380, 50 2 19.2 110 2×2.5 6.8 30/90 8.5/53
FG(R)60/B(2)-G 3,380, 50 2 22.1 110 2×2.5 6.8 30/100 8.5/60.3
FG(R)55/B-G 3,380, 50 1 34.0 225 2×2.5 6.8 30/80 8.5/47.5
FG(R)65/B-G 3,380, 50 1 41.4 272 2×2.5 6.8 30/95 8.5/56.8
FG(R)20/C-M 3, 380, 50 1 16.4 95 1.5 2.7 15/35 3.4/22
FG(R)25/C-M 3,380,50 1 19.2 110 2.5 2.7 15/45 3.4/26.5
FG(R)30/C-M 3,380,50 1 22.1 110 2.5 3.6 15/50 4.5/30.1
FG(R)40/C-M 3,380, 50 1 26.9 168 2.5 4.98 15/60 6.2/36.1

16
Duct Type Split Air Conditioners Technical Sales Guide

5 FAN PERFORMANCE CURVES

FGR20/B-G、FG20/B-G
FGR20/C-M、FG20/C-M
External Static Pressure(Pa)

External Static Pressure(in.wg)


120 0.48

110 0.44

100 0.40

90 0.36

80 0.32

70 0.28
4154 4000 3813 2445 2354 2244

Air Flow(m3/h) Air Flow(CFM)

FGR25/B-G、FG25/B-G
FGR25/C-M、FG25/C-M
External Static Pressure(Pa)

External Static Pressure(in.wg)

120 0.48

110 0.44

100 0.40

90 0.36

80 0.32

70 0.28
4895 4800 4575 2934 2825 2693

Air Flow(m3/h) Air Flow(CFM)

FGR30/B-G、FG30/B-G
FGR30/C-M、FG30/C-M
External Static Pressure(Pa)

External Static Pressure(in.wg)

160 0.64

150 0.60

140 0.56

130 0.52

120 0.48

110 0.44
5712 5500 5243 3362 3237 3086

Air Flow(m3/h) Air Flow(CFM)

17
d

FGR40/B-G、FG40/B-G
FGR40/C-M、FG40/C-M
External Static Pressure(Pa)

External Static Pressure(in.wg)


160 0.64

150 0.60

140 0.56

130 0.52

120 0.48

110 0.44
7270 7000 6672 4279 4120 3927
3
Air Flow(m /h) Air Flow(CFM)

FGR50/B(2)-G、FG50/B(2)-G
External Static Pressure(Pa)

External Static Pressure(in.wg)

190 0.76

180 0.72

170 0.68

160 0.64

150 0.60

140 0.56
11425 11000 10485 6724 6474 6171

Air Flow(m3/h) Air Flow(CFM)

FGR55/B-G、FG55/B-G
External Static Pressure(Pa)

External Static Pressure(in.wg)

190 0.76

180 0.72

170 0.68

160 0.64

150 0.60

140 0.56
9348 9000 8579 5502 5297 5049

Air Flow(m3/h) Air Flow(CFM)

18
Duct Type Split Air Conditioners Technical Sales Guide

FGR65/B-G、FG65/B-G
External Static Pressure(Pa)

External Static Pressure(in.wg)


190 0.76

180 0.72

170 0.68

160 0.64

150 0.60

140 0.56
11425 11000 10485 6724 6474 6171

Air Flow(m3/h) Air Flow(CFM)

6 CLEARANCE DATA
6.1 Outdoor Unit

Side with Electrical Box


>3000
>1000

>1000 >1200
>1000

Schematic map for the installation of single outdoor unit

19
d

>300 >300 >300

Schematic map for the installation of single outdoor unit

6.2 Indoor Unit

>1000 >560

Air supply
>1000

Air return

20
Duct Type Split Air Conditioners Technical Sales Guide

7 DIMENSION DATA
7.1 Outdoor Unit

Unit: mm
Model A B C
FG(R)20/C-M(O) 1150 360 1350
FG(R)25/C-M(O) 1150 422 1600

840
1772

A 880 B±2

C±2
844±2

21
d

Unit: mm
Model A B C
FG(R)20/B-G(O)、FG(R)25/B-G(O)、FG(R)30/B-G(O) 990 787 337
FG(R)40/B-G(O) 1290 1160 850
FG(R)30/ C-M (O) 990 787 337
FG(R)40/C-M(O) 1290 1160 850

Note

FG(R)50/B(2)-G(O) is made up of two FG(R)25/B-G(O) , FG(R)60/B(2)-G is made up of two


FG(R)30/B-G(O).

Unit: mm
Model A B C D E F H
FG(R)55/B-G(O)
1980 840 920 1400 460 880 1760
FG(R)65/B-G(O)

22
Duct Type Split Air Conditioners Technical Sales Guide

7.2 Indoor Unit


C D
E F
Air Oulet
Air Return

B
Air Return F Air Oulet E
D C
A
A

FG(R)20/B-G(I)、FG(R)25/B-G(I) FG(R)40/B-G(I)、FG(R)50/B(2)-G(I)
FG(R)30/B-G(I) FG(R)60/B(2)-G(I)、FG(R)55/B-G(I)
FG(R)20/C-M(I) FG(R)30/C-M(I) FG(R)65/B-G(I)
FG(R)25/C-M(I) FG(R)40/C-M(I)

Unit: mm
Model A B C D E F
FG(R)20/B-G(I)
FG(R)25/B-G(I) 1560 910 1194 1194 292 342
FG(R)30/B-G(I)
FG(R)40/B-G(I) 1780 1040 868 1450 347 555
FG(R)50/B(2)-G(I) 1980 1040 1120 1650 347 600
FG(R)60/B(2)-G(I) 1980 104 1120 1650 347 755
FG(R)55/B-G(I) 1980 1040 1120 1650 347 600
FG(R)65/B-G(I) 1980 104 1120 1650 347 755
FG(R)20/C-M(I)
1560 910 331 1194 292 342
FG(R)25/C-M(I)
FG(R)30/C-M(I) 1560 910 1194 1194 292 342
FG(R)40/C-M(I) 1780 1040 868 1450 347 555

23
d

7.3 Controller

Wired Remote Controller

Remote Controller(Optional)

85

158.7
85

Central Controller(Optional)
96

56

96

24
Duct Type Split Air Conditioners Technical Sales Guide

8 WIRING DIAGRAM
8.1 Indoor Unit
FG20/B-G(I)、FG25/B-G(I)、FG30/B-G(I)、FGR20/B-G(I)、FGR25/B-G(I)、FGR30/B-G(I)

FG40/B-G(I)、FGR40/B-G(I)

25
d

FG50/B(2)-G(I)、FG60/B(2)-G(I)、FGR50/B(2)-G(I)、FGR60/B(2)-G(I)、
FGR55/B-G(I)、FGR65/B-G(I)

Model Recommendatory sectional area of electrical wire (mm2)


FG(R)20/B-G(I) 2.5
FG(R)25/B-G(I) 2.5
FG(R)30/B-G(I) 2.5
FG(R)40/B-G(I) 2.5
FG(R)50/B(2)-G (I) 6.0
FG(R)60/B(2)-G (I) 6.0
FG(R)55/B-G (I) 6.0
FG(R)65/B-G (I) 6.0
FGR20/C-M (I) 2.5
FGR25/C-M (I) 2.5
FGR30/C-M (I) 2.5
FGR40/C-M (I) 2.5
FG20/C-M (I) 1.0
FG25/C-M (I) 1.0
FG30/C-M (I) 1.0
FG40/C-M (I) 1.5

The specification of power cord mentioned hereby is defined as the required specification when wiring
with BV single core cable(2~ 4pieces)under the cover of PVC pipe, and environment temperature
shall be at 40℃; Air switch shall be selected according to 40℃ temperature condition, and shall in
“ D” Type. If the installation condition on site changed, please consider the modification on the
required specification of Power cord and Air switch, according to the specification manual provided by
manufacture.

26
Duct Type Split Air Conditioners Technical Sales Guide

FG20/C-M( I),FG25/C-M( I),FG30/C-M( I),FG40/C-M(I),

27
d

FGR20/C-M( I),
FGR25/C-M( I),
FGR30/C-M(I),
FGR40/C-M(I),

28
Duct Type Split Air Conditioners Technical Sales Guide

8.2 Wiring Diagram-Condensing Units


FG20/B-G(O) FG25/B-G(O) FG30/B-G(O)

FGR20/B-G(O)、FGR25/B-G(O)、FGR30/B-G(O)

29
d

FG40/B-G(O)

FGR40/B-G(O)

30
Duct Type Split Air Conditioners Technical Sales Guide

FG55/B-G(O)、FG65/B-G(O)

FGR55/B-G(O)、FGR65/B-G(O)

31
d

Model Recommendatory sectional area of electrical wire (mm2)


FG(R)20/B-G(O) 10
FG(R)25/B-G(O) 16
FG(R)30/B-G(O) 16
FG(R)40/B-G(O) 25
FG(R)55/B-G(O) 35
FG(R)65/B-G(O) 50
FG(R)20/C-M (O) 4.0
FG(R)25/C-M (O) 4.0
FG(R)30/C-M (O) 4.0
FG(R)40/C-M (O) 6.0

The specification of power cord mentioned hereby is defined as the required specification when wiring
with BV single core cable(2~ 4pieces)under the cover of PVC pipe, and environment temperature
shall be at 40℃; Air switch shall be selected according to 40℃ temperature condition, and shall in
“ D” type. If the installation condition on site changed, please consider the modification on the
required specification of Power cord and Air switch, according to the specification manual provided by
manufacture.

FG20/C-M( O);FG25/C-M( O);

32
Duct Type Split Air Conditioners Technical Sales Guide

FGR20/C-M( O);FGR25/C-M(O);

FG30/C-M( O);FG40/C-M( O);

33
d

FGR30/C-M( O);

FGR40/C-M(O);

34
Duct Type Split Air Conditioners Technical Sales Guide

8.3 Field Wiring Diagrams

35
Gree Electric Appliance, Inc. of Zhuhai, founded in 1991, is the world's largest air conditioner
enterprise integrating R&D, manufacturing, marketing and services.

Technology Innovation and quality are always our priority. With efforts of thousands of Gree's
engineers, we own more than 3000 patents for our products.

Nowadays, we have 6 production bases in Zhuhai, Chongqing, and Hefei(China), as well as


Brazil, Pakistan and Vietnam, with annual production capacity of 27 million sets of residential air
conditioners and 2 million sets of commercial air conditioners.

With the installation of Gree commercial air conditioners in important projects at home and abroad
like Media Village for 2008 Beijing Olympic Games, Stadiums for 2010 World Cup in South Africa,
as well as India Telecom base station, Gree commercial air conditioners are ready to develop
steadily to every corner in the world, to present a more comfortable and harmonious working
environment and family atmosphere.

Add: West Jinji Rd,Qianshan Zh uhai,Guangdong,China 519070


Tel: (+86-756)8614883 Fax: (+86-756)8614998
Http://www.gree.com Em ail: gree@g ree.com. cn