Modulo IO DSQC 652
Modulo IO DSQC 652
Description
Illustration
xx0600002855
Parts
Item Description
A Status LEDs
X1 Digital outputs
See section Connector X1 on page 80 for connection table!
X2 Digital outputs
See Connector X2 on page 81for connection table!
X3 Digital inputs
See Connector X3 on page 81 for connection table!
X4 Digital inputs
See Connector X4 on page 82 for connection table!
3HAC020676-001 Revision: G 79
6 Boards and units
6.2.3. DSQC 652, Digital I/O
Item Description
X5 DeviceNet connector
See Connector X5 on page 82!
Technical data
No. of inputs 16
No. of outputs 16
Supply voltage 24 VDC
Supply source 24 V I/O or separate external supply
SW connections Support for the following connections:
• Polled
• Change-Of-State
• Change-Of-State with acknowledge suppression
• Cyclic
• Cyclic with acknowledge suppression
For descriptions of the different types of I/O connections, see
I/O messages - connection types on page 11.
Baudrate Autodetect; the unit will detect the baud rate automatically.
NOTE!
When the master baud rate is changed disconnect the power
to the unit(s) before the system is restarted, reconnect the
power when the master is up and running.
This is required for the unit(s) to be able to establish a new
connection with the master.
Unit setup
Connector X1
xx0200000264
80 3HAC020676-001 Revision: G
6 Boards and units
6.2.3. DSQC 652, Digital I/O
Connector X2
xx0200000264
Connector X3
xx0200000264
3HAC020676-001 Revision: G 81
6 Boards and units
6.2.3. DSQC 652, Digital I/O
Connector X4
xx0200000264
Connector X5
xx0100000244
LEDs
82 3HAC020676-001 Revision: G
6 Boards and units
6.2.3. DSQC 652, Digital I/O
Input map
xx0300000613
Output map
en0400000716