Fuji Electric VFZ Series Operating Manual JEC PDF
Fuji Electric VFZ Series Operating Manual JEC PDF
Fuji Electric VFZ Series Operating Manual JEC PDF
RING COMPRESSOR
VFZ-7W(5W) Standard Model Series
VFC805A-7(5)WS
WARNING
• Read the instruction manual carefully before you install, put into operation and maintain
the Ring Compressor and handle it properly.
• For the sake of safety, never modify the Ring Compressor.
We take no responsibility for the troubles caused by repairing or modifying the product.
• Hand over this instruction manual surely to the end users, who actually install, operate
and maintain the Ring Compressor.
• After having read the instruction manual, keep it at the place, where can be accessed
by the persons, who use it.
• The specification of the product may be changed without prior notification.
CONTENTS ............................................................................................................................... - 1 -
1.INTRODUCTION ................................................................................................................... - 2 -
4.TRANSPORT ........................................................................................................................ - 7 -
5.SAFEKEEPING .................................................................................................................... - 7 -
8.OPERATION ....................................................................................................................... - 12 -
11.SPECIFICATION .............................................................................................................. - 22 -
It is required for the Ring Compressor for give full play to its performance, for preventing troubles from
occurring and for continuing its satisfactory operation for a long period not only to maintain and inspect
it after putting it into service but also to handle it properly in every stage after its delivery until its actual
operation.
This instruction manual illustrates the essential items for handling the Ring Compressor.
If you find any question, please inquire of our special agent, dealer or business office about it.
Danger
: those items, for which the possibility of human DEATH and
HEAVY INJURY are feared, if they are mishandles.
Even those items marked with Warning may lead to serious results depending upon the
situation.
• Ground the protective earthing terminal surely. Use the wiring of AWG 14(2.1mm2) for
VFZ 40 to 60 type, the wiring of AWG 12(3.3mm2) for VFZ 70 type, the wiring of AWG
10(5.3mm2) for VFZ 80 to 90 type, and ground it near the product.
Installation, Otherwise, an ELECTRIC SHOCK or a FIRE is feared.
Adjustment
• In the Ring Compressor is used as mounted on a ceiling or a wall, its fall is feared
depending on its mounting condition. Observe the catalog or instruction manual for the
details of usable range. An INJURY due to a FIRE is feared.
• Connect it to the power supply cable according to the wiring diagram within terminal
box and the instruction manual. An ELECTRIC SHOCK or a FIRE due to incorrect
connection is feared.
• Use it always at the voltage and frequency indicated in the nameplate on its main body.
Piping, A BURNOUT or a FIRE is feared.
Wiring
• Do not bend, stretch or pinch the power supply cable and the lead wire for the Ring
Compressor by force. An ELECTRIC SHOCK or a FIRE is feared.
• Restore the cover for terminal box to the original position after completion of every
work. Otherwise, an ELECTRIC SHOCK is feared.
• Never access or touch any rotating body (cooling fan etc.) during running. A CATCH-IN
on an INJURY is feared.
• Switch off the power supply always in case of power failure. An INJURY is feared due
to sudden work of the machine at restoration of power supply.
• Switch off the power supply always when the Ring Compressor is stopped because the
Operation
protection unit belonging to it worked. An INJURY is feared due to sudden work of Ring
Compressor at recovery of the protection unit.
• Do not run the Ring Compressor at the frequency exceeding 60Hz (50Hz* for models
dedicated to 50Hz*). Otherwise, it may lead to a BURN, a FIRE, DAMAGE, or an
INJURY. ※50 Hz operation is not covered by UL.
• Take full care of fall and tumbling down during transportation. An INJURY is feared.
• Lift up the Ring Compressor equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Compressor on a
machine, do not lift up the entire machine using the mounted hanger bolt.
Verify the mass of motor based in the nameplate, package box, outline drawing,
catalog or the like before lifting it and do not lift any more mass than the rated load
of lifting tool. The gravity center of the Ring Compressor is located at motor side,
therefore, the Ring Compressor inclines to one side during lift-up.
Exert tension gradually on the wire and do not lift up suddenly.
Transportation This lift-up work may only be executed by the qualified workers. Do not stay under
the Ring Compressor during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of
these cases.
• When lifting the Ring Compressor without a hanger bolt, pay attention to its weight.
Do not allow a single person to lift the product heavier than 15kg. Failure to
observe this may cause an INJURY.
• Ambient temperature should be kept –20℃~+50℃ during transportation.
• Open the package after verifying the top and bottom of product. An INJURY is
feared.
• Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
Opening the
Package • Verify if the product is just the ordered one. An INJURY, DAMAGE or a FIRE due
to use of the incorrect product is feared.
• Verify if no part of the product is damaged during transportation and if all fastening
parts including bolts and nuts are securely tightened.
• Never place any inflammable material around the Ring Compressor. A FIRE is
feared.
• Do not place any obstacle against ventilation around the Ring Compressor. A
BURN or a FIRE caused by abnormal heating due to disturbed cooling is feared.
• Fasten the foundation bolts surely.
Insufficient fastening may cause an INJURY and DAMAGE due to shift of the Ring
Installation,
Compressor.
Adjustment
• Never get on or hang on the Ring Compressor. An INJURY is feared.
• Ring Compressor shell be always mounted on suitable place in order to see its
nameplate easily and do not put any obstacle in front of it.
Do not dismount the nameplate.
Piping, • For measuring the insulation resistance, do not touch the terminal. An ELECTRIC
Wiring SHOCK is feared.
• No protection unit belongs to the Ring Compressor except for some models. The
installing of overcurrent protection unit is obliged based upon the technical
standard for electrical equipment. For preventing a FIRE and DAMAGE due to a
motor burnout, we recommend to install the protection unit other then overcurrent
protection units (including a ground fault interrupter) based upon consulting with us.
• If any abnormality occurs, stop the operation immediately and switch off the power
supply. An ELECTRIC SHOCK an INJURY or a FIRE is feared.
• The Ring Compressor becomes considerably hot during its operation. Take care
Operation not to touch it by your hand or body. A BURN is feared.
• Do not insert your finger or any others material into the opening of Ring
Compressor. An ELECTRIC SHOCK an INJURY or FIRE is feared.
• Wear stopples during operation to shut the big noise.
• Do not touch the terminal for measuring the insulation resistance. An ELECTRIC
SHOCK is feared.
• The Ring Compressor becomes considerably hot during its operation. Take care
Maintenance
not to touch by your finger and body. A BURN is feared.
, Inspection
• Take care, if you use a solvent or the like for cleaning the Ring Compressor. A
POISONING is feared. Further, the use of thinner or benzene may cause
discoloring or exfoliation of coating on the Ring Compressor.
Disassembly, • The repair, disassembling and modification shall be executed only by experts. An
Repair, INJURY due to the edge of Impeller or key groove, an ELECTRIC SHOCK or a
Modification FIRE is feared.
Disposal • Handle the Ring Compressor as a general industrial waste, when it is be disposed.
Warning
1. Verify the top and the bottom of product and open the package.
Otherwise, an INJURY is feared.
2. Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
3. Verify if the delivered product is just the ordered one.
(Check the output voltage, frequency, model etc. with the description on face plate.)
An INJURY, DAMAGE or a FIRE is feared, if an incorrect product is used.
4. Verify if any part is damaged and if any bolt or nut is loosened during the transport.
3.2 Location of name plate, warning labels and electric shock warning labels
The figure below shows the locations of name plate, warning labels and electric shock warning
labels.
A B
Warning label
Nameplate
Nameplate
Electric shock
Warning label
Nameplate
Warning label
Warning label
View from A View from B
VFZ601~701A-7W(5W) VFZ801~VFZ901A-7W(5W)
VFZ401~VFZ501A-7W(5W)
Warning
1. Take full care of fall and tumbling down during transportation. An INJURY is feared.
2. Lift up the Ring Compressor equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Compressor on a machine,
do not lift up the entire machine using the mounted hanger bolt.
Verify the mass of motor based in the nameplate, package box, outline drawing,
catalog or the like before lifting it and do not lift any more mass than the rated load of
lifting tool. The gravity center of the Ring Compressor is located at motor side,
therefore, the Ring Compressor inclines to one side during lift-up.
Exert tension gradually on the wire and do not lift up suddenly.
This lift-up work may only be executed by the qualified workers. Do not stay under
the Ring Compressor during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of these
cases.
3. When lifting the Ring Compressor without a hanger bolt, pay attention to its weight.
Do not allow a single person to lift the product heavier than 15kg. Failure to observe
this may cause an INJURY.
5.Safekeeping
Take care of following points for safekeeping the Ring Compressor or suspending its operation for a
long period.
Fan cover
Cooling fan
Casing cover
Impeller
Suction port
Discharge port
Silencer Middle bracket (Cross section of VFZ601A-7W)
Danger
1. Ground the protective earthing terminal surely. Use the wiring of AWG 14(2.1mm2) for
VFZ 40 to 60 type, the wiring of AWG 12(3.3mm2) for VFZ 70 type, the wiring of AWG
10(5.3mm2) for VFZ 80 to 90 type, and ground it near the product. An ELECTRIC
SHOCK or a FIRE is feared.
2. In case of using the Ring Compressor mounted on a ceiling or wall, its fall is feared
depending upon the condition. Follow the catalog or instruction manual for details of
usable range.
INJURY caused by its FALL is feared.
Warning
3. Never place any inflammable object around the Ring Compressor.
A FIRE is feared.
4. Do not place any obstacle, which disturbs the ventilation, around the Ring
Compressor.
A BURN or a FIRE caused by abnormal heating is feared, due to the disturbed
ventilation.
5. Fasten the foundation bolts surely before starting the operation. An INJURY or
DAMAGE due to shift of the Ring Compressor is feared, if the fastening is insufficient.
6. Never step on or hang from the Ring Compressor.
An INJURY is feared.
7. Make the nameplate for the Ring Compressor always easily legible and do not place
any obstacle in front of it. Do not dismount the face plate.
Warning
1. Outdoor/indoor: Install at an indoor site, which is exposed to no wind and rain
Otherwise, an ELECTRIC SHOCK or a FAULT is feared.
2. Ambient temp./ Use it in the range from -10 to 40℃. Otherwise, shortening of life
transported gas: and a FAULT is feared. The transported gas should be standard
air. (No freezing is allowed.)
3. Relative humidity / Use relative humidity in 80% or less and 1000m above sea level
altitude: or less. Shortening of life or FAULT is feared.
4. Atmosphere / If can neither be used in a place, where any such corrosive liquid
transported gas: or gas as an acid or an alkali or any inflammable or explosive
gas exists, nor trans port such material. A FIRE, a FAULT or an
INJURY is feared.
5. Dusts: Evade a place, where a lot of dusts, wastes or thread chips exist.
If inevitable, clean the dusts and wastes adhered in the Ring
compressor regularly.
A FIRE or a FAULT is feared
6. Ventilation: Select a well ventilated place. It shell not be used in a closed
room or in a case. A FIRE, a BURN or a FAULT is feared.
7. Ambient air: Evade a narrow place, for the convenience of maintenance and
inspection.
mm mm N・m
9. Install the Ring Compressor so as to be used in horizontal shaft condition. For installing it in
vertical or slant shaft condition, install it so that its compressor side lies under its motor side
(Figure 2). ※VFZ701~VFZ901: Horizontal shaft condition only
<Good!> <No good!>
① ② ③ ④ ⑤
7.3 Observe the following points in piping work and wiring work.
Danger
1. Connect it to the power supply cable according to the wiring diagram within terminal box
and the instruction manual. An ELECTRIC SHOCK or a FIRE due to incorrect
connection is feared.
2. Use it always at the voltage and frequency indicated in the nameplate on its main body.
A BURNOUT or a FIRE is feared.
3. Do not bend, stretch or pinch the power supply cable and the lead wire for the Ring
Compressor by force. An ELECTRIC SHOCK or a FIRE is feared.
4. Restore the cover for terminal box to the original position after completion of every work.
Otherwise, an ELECTRIC SHOCK is feared.
Warning
5. Ground the protective earthing terminal surely.
An ELECTRIC SHOCK or a FIRE is feared.
6. Construct the piping and wiring according to the technical standard for electrical
equipment and the internal wiring provisions. A BURNOUT or a FIRE is feared.
7. For wiring to the terminal base in terminal box, fasten the terminal screws with a torque
of 1.0 to 1.3 N・m. Otherwise, DAMAGE of the terminal box is feared.
8. For measuring the insulation resistance, do not touch the terminal. An ELECTRIC
SHOCK is feared.
9. No protection unit belongs to the Ring Compressor except for some models. The
installing of overcurrent protection unit is obliged based upon the technical standard for
electrical equipment. For preventing a FIRE and DAMAGE due to a motor burnout, we
recommend to install the protection unit other then overcurrent protection units (including
a ground fault interrupter) based upon consulting with us.
10. As the motor load (current) changes depending upon the air flow used by the Ring Compressor,
refer to the characteristics curve for setting the wiring capacity and protection relay.
11. Use such pipes as PVC-pipes, gas pipes, flexible hoses etc., which can hold the Ring
Compressor pressure and hoses other then metallic one for discharge side, use those once,
which have a sufficient high-temperature resistance.
Lay piping so surely as to have no leakage (Figure 3).
Ideally, use pipes having the same Economical for high pressure
diameter as standard pipes. and small Air flow, as small
pipes may be used.
12. Do not allow any foreign material to intrude into the compressor.
13. The rotation direction shall be the arrow direction on the casing. The rotation direction can be
seen at the shaft end at counter-compressor side and it is also correct, if the wind direction
coincides with the IN and OUT indicated at the pipe connection port. Reverse rotation is allowed,
although the performance is reduced.
14. Connect the power cables by using gland or electrical conduit at wiring hole of the terminal box to
protect dust, foreign objects, water and etc. into the terminal box inside. Do not remove the
unused rubber bushes of VFZ501~VFZ901. Do not use the rubber bushes to wiring.
15. Take care of edge of wiring holes at the terminal box. An INJURY is feared.
16. Wire the power cables with motor terminals surely according to wiring figure in the terminal box or
Figure 4.
Connecting
method
Wires 5 wires
Connecting
method
17. Limit the fluctuations of the supply voltage within ±10% of the rated voltage, and also limit the
fluctuations of the frequency between –5% and +3% of the rated value. Although you can run the
Ring Compressor in these ranges, avoid continuous operation if the voltage is not within ±5% of
the rated value or if the frequency is not within ±2% of the rated value. Even if the power
fluctuations fall within the allowable ranges, the Ring Compressor characteristics and motor
characteristics may differ from those at the rated voltage and frequency.
18. Before operating the Ring Compressor, check the following points again.
・ Check that the equipment is correctly wired.
・ Check that the equipment is securely grounded.
・ Check that an appropriate ground fault interrupter and an overload protection device are
installed.
・ Check that none of the three terminals of the motor has come loose or disconnected.
In case of running the motor with connection of only two terminals, it may cause an
open-phase operation, thus leading to motor burnout.
8.Operation
Verify the following points for operating the Ring Compressor.
Danger
1. Never access or touch the rotating body (cooling fan etc.) during running. CATCH-IN
or INJURY is feared.
2. Turn the power supply switch off in case of power failure.
INJURY is feared, when the machine runs suddenly at the power restoration.
3. Be sure to turn the power supply switch off, in the Ring Compressor has been stopped
because the attached protection unit has been activated. An INJURY is feared, as the
machine may run suddenly at the power restoration.
4. Do not run the Ring Compressor at the frequency exceeding 60Hz (50Hz for models
dedicated to 50Hz). Otherwise, it may lead to a BURN, a FIRE, DAMAGE, or an
INJURY. ※50 Hz operation is not covered by UL.
12. The Ring Compressor will be continuously at within the operation range shown on the wind flow
rate to static pressure curve (shown in the catalog). This operation range is so wide that the
machine can be operated at nearly closed pressure but, if you operate it at high pressure,
especially take care not to exceed the operation range. If you must operate it at closed condition,
arrange a bypass hole on the way, so that a more wind than required range flows through the
compressor even if the suction port is closes (Figure 5).
Bypass hole
Valve
Piping
(Figure 5)
Suction
Blow
(Suction)
(Blow)
(Figure 6)
Switch suction and blow using the valve.
15. Remove any solid object, dust, thread chip, water drop or the like before entering into the Ring
Compressor. Even if make no dust be sucked directly, take measures not to suck any dust
staying around by mistake. Use of the dust staying around by mistake. Use of the dust collection
sack in a vacuum cleaner or the like is recommended.
Also, it is recommended to use a filter having considerably large space. Remove sometimes the
dust collected in the filter. It may also be possible to make the dust blow off by reversing the Ring
Compressor, if it is possible.
16. If dusts adhered inside and outside of the compressor (especially in the cooling air path for
cooling fan cover), remove them. If adhered dusts increase, it causes such troubles as a
temperature rise, a sink of wind flow rate and an increase vibration.
17. As the motor load (current) changes depending upon the air flow used by the Ring Compressor,
refer to the characteristics curve for setting the wiring capacity and protection relay.
18. The bearing and silencer are consumables and need to be changed when their lives are arrived.
Depending on the environment, in which the machine was used, the Impeller, casing, casing
cover, and wire net are also included in consumables. (Please notice discharge and suction
material is different from VFZ50’s and VFZ60’s silencers when you exchange them.)
Silencer 2 years
Temperature RISE K
Temperature RISE K
Motor
Casing
Casing cover
Silencer
*The temperature of the air passing through the
Ring Compressor rises. Especially it reaches
a high temperature at a nearly closed
condition.
(Figure 8)High temperature part of the Ring Compressor
Warning
1. Always only the expert shall investigate, repair, disassemble and modify the fault. An
INJURY due to the Impeller edge or key groove, an ELCTRIC SHOCK or a FIRE is
feared.
2. If the Ring Compressor must be abandoned as the result of investigation in a rare
possibility, dispose it as a general industrial waste.
3. If the investigation result shows that the machine cannot be easily repaired, if you will
request any spare part or you have any trouble, contact our agent, dealer or business
office at any time. In case of contacting us, please verify following items in advance:
(a) Model indicated in the nameplate,
(b) SER. No.,
(c) Details of the fault,
(d) Name of faulty part, name of spare parts,
(e) Required quantity and
(f) Kind of gas to be transported (e.g. Air)
Does not Stator and rotor come into contact Replace bearing.
rotate due to bearing fault.
Foreign material involved in blades. Remove it.
Power failure Consult with utility company.
2 phases of power supply connection Replace them.
No sound wires disconnected.
2 phases of stator coils disconnected. Request factory to repair them.
Part No. Name of Part Part No. Name of Part Part No. Name of Part
1-2 Bolt (for Casing cover) 3-5 Bearing at driving side 5-1 Terminal box
2-2 Bolt (for Casing) 3-8 Bolt (for fastening Fan wheel) 5-6 Packing (for Terminal box cover)
2-3 Spring washer 3-9 Claw washer 5-7 Bolt (for Terminal box cover)
2-4 End cover 3-11 Key (for Fan Wheel) 5-8 Bush (for Terminal box)
Bolt
2-5 Bolt (for End cover) 3-12 Motor cooler fan 5-9
(for Protective earthing terminal)
Bush
2-6 Spring washer 3-13 Bolt (for Motor cooler fan) 5-20
(for Leader mouth for Terminal box)
2-7 Silencer (1 set) 4-1 Frame/Stator assembly 5-21 Bolt (for Motor)
2-7-1 Silencer (Suction side) 4-4 Shield at counter-driving side 5-22 Nut (for Motor)
Spring washer
2-17 Bolt (for Silencer box) 4-15
(Shield, frame)
Spring washer
2-20 4-17 Bolt (Middle bracket, frame)
(for Silencer box)
1
VFZ401A-7W 1.1 0.85 3.3-3.2/1.6 53 12.9 0 0 F 69.5 NPSC 1 /2 33.3-36.0/18.0 21.0 46
VFZ501A-7W 2.4 1.8 6.9-6.7/3.4 82 20.8 0 0 F 74.5 NPSC 11/2 69-76/38 35.0 77
VFZ601A-7W 4.4 3.3 11.2-10.8/5.4 95 23.6 0 0 F 74.5 NPSC 2 119-132/66 49.0 108
VFZ701A-7W 6.4 4.8 16.2-15.3/7.7 99 25.1 0 0 F 79.5 NPSC 2 189-210/105 61.0 134
VFZ801A-7W 10.4 7.8 23.0-22.1/11.0 108 26.6 0 0 F 81 NPSC 21/2 252-270/135 95.5 211
VFC805A-7WS 10.4 7.8 23.0-22.1/11.0 108 26.6 0 0 F 81 NPSC 21/2 252-270/135 130.0 287
VFZ901A-7W 13.7 10.3 33.9-33.7/17.0 85 21.5 146 4.2 F 83 NPSC 3 456-500/250 117.5 259
VFZ401A-5W 0.85 0.85 1.2 53 12.9 0 0 F 69.5 NPSC 11/2 28.8 21.0 46
VFZ501A-5W 1.8 1.8 2.7 82 20.8 0 0 F 74.5 NPSC 11/2 30 35.0 77
VFZ601A-5W 3.3 3.3 4.2 95 23.6 0 0 F 74.5 NPSC 2 53 49.0 108
VFZ501A-5W 4.8 4.8 6.0 99 25.1 0 0 F 79.5 NPSC 2 84 61.0 134
VFZ801A-5W 7.8 7.8 8.4 108 26.6 0 0 F 81 NPSC 21/2 108 95.5 211
VFC805A-5WS 7.8 7.8 8.4 108 26.6 0 0 F 81 NPSC 21/2 108 130.0 287
VFZ901A-5W 10.3 10.3 13.2 85 21.5 146 4.2 F 83 NPSC 3 200 117.5 259
The maximum static pressure of the delivery character is the value near the discharge port, and it is the value of
S uc t ion c harac t er
Maximum value Approximate
MInimum Noise Starting
Insulation Suction/delivery mass
Model Output Pressure air quantity value current
Current class bore diameter
【dB(A)】 【A】
【A】 3
【HP】 【kW 】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【 kg】 【 lbs 】
1
VFZ401A-7W 0.71 0.53 2.7/1.3 39 9.4 0 0 F 65.5 NPSC 1 /2 32.5/16.3 21.0 46
VFZ501A-7W 1.7 1.3 6.0/3.0 55 13.7 0 0 F 70.5 NPSC 11/2 71/35.5 35.0 77
VFZ601A-7W 3.1 2.3 9.8/4.9 72 18.2 0 0 F 70.0 NPSC 2 120/60 49.0 108
VFZ701A-7W 4.1 3.1 12.7/6.3 78 18.3 0 0 F 75.0 NPSC 2 195/97.5 61.0 134
VFZ801A-7W 6.9 5.2 18.8/9.4 88 21.6 0 0 F 78.0 NPSC 21/2 268/134 95.5 211
VFC805A-7WS 6.9 5.2 18.8/9.4 88 21.6 0 0 F 78.0 NPSC 21/2 268/134 130.0 287
VFZ901A-7W 9.3 7 24.5/12.2 63 19.7 111 3.2 F 79.5 NPSC 3 438/219 117.5 259
Recommended Equipment *3
Blower Motor Controllers, Manual *4 Magnetic Contactors Electromagnetic Relay Push button switches
Model Voltage(V) Model Setting current File No. Model Specification File No. Model Specification File No. Model File No.
208 BM3RSB-6P3 4A E163944 SC-03 200V 7.8A E42419 HH52 200V E42419 AR22 E44592(UL)
VFZ401A-7W 230 BM3RSB-6P3 4A SC-03 200V 7.8A LR20479(CSA)
460 BM3RSB-2P5 2A SC-03 200V 7.8A
208 BM3RSB-010 8A SC-0 200V 11A
VFZ501A-7W 230 BM3RSB-010 8A SC-0 200V 11A
460 BM3RSB-004 4A SC-03 200V 7.8A
208 BM3RSB-016 14A SC-4-0 200V 17.5A
VFZ601A-7W 230 BM3RSB-016 14A SC-4-0 200V 17.5A
460 BM3RSB-010 7A SC-03 200V 7.8A
208 BM3RSB-025 21A SC-N1 200V 25.3A
VFZ701A-7W 230 BM3RSB-025 22A SC-N1 200V 25.3A
460 BM3RSB-013 11A SC-4-0 200V 17.5A
208 BM3VSB-050 28A SC-N2 200V 32.2A
VFZ801A-7W 230 BM3VSB-050 30A SC-N1 200V 25.3A
460 BM3RSB-020 14A SC-4-1 200V 17.5A
208 BM3VSB-050 28A SC-N2 200V 32.2A
VFC805A-7WS 230 BM3VSB-050 30A SC-N1 200V 25.3A
460 BM3RSB-020 14A SC-4-1 200V 17.5A
208 BM3VSB-063 48A SC-N2 200V 32.2A
VFZ901A-7W 230 BM3VSB-063 52A SC-N2 200V 32.2A
460 BM3RSB-032 26A SC-N1 200V 25.3A
VFZ401A-5W 575 BM3RSB-2P5 1.6A SC-03 200V 7.8A
VFZ501A-5W 575 BM3RSB-004 3.2A SC-03 200V 7.8A
VFZ601A-5W 575 BM3RSB-6P3 5.5A SC-03 200V 7.8A
VFZ501A-5W 575 BM3RSB-013 9A SC-4-0 200V 17.5A
VFZ801A-5W 575 BM3RSB-020 14A SC-4-1 200V 17.5A
VFC805A-5WS 575 BM3RSB-020 14A SC-4-1 200V 17.5A
VFZ901A-5W 575 BM3RSB-025 21A SC-N1 200V 25.3A
*3 Recommended equipment is a reference model manufactured by Fuji Electric.
*4 UL evaluation test was carried out at the protector (MMS).