Instruction manual

RING COMPRESSOR
VFZ-7W(5W) Standard Model Series
VFC805A-7(5)WS

WARNING
• Read the instruction manual carefully before you install, put into operation and maintain
the Ring Compressor and handle it properly.
• For the sake of safety, never modify the Ring Compressor.
We take no responsibility for the troubles caused by repairing or modifying the product.
• Hand over this instruction manual surely to the end users, who actually install, operate
and maintain the Ring Compressor.
• After having read the instruction manual, keep it at the place, where can be accessed
by the persons, who use it.
• The specification of the product may be changed without prior notification.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Jamieson Equipment Company
www.jamiesonequipment.com
toll free 800.875.0280
Contents
Page

CONTENTS ............................................................................................................................... - 1 -

1.INTRODUCTION ................................................................................................................... - 2 -

2.WARNINGS FOR SAFETY................................................................................................... - 2 -

3.PACKAGE OPENING AND PRODUCT VERIFICATION ..................................................... - 6 -

4.TRANSPORT ........................................................................................................................ - 7 -

5.SAFEKEEPING .................................................................................................................... - 7 -

6.NAME OF PARTS ................................................................................................................ - 8 -

7.INSTALLATION , PIPING AND WIRING .............................................................................. - 8 -

8.OPERATION ....................................................................................................................... - 12 -

9.FAULTS AND COUNTERMEASURES .............................................................................. - 16 -

10.PARTS LIST AND DISASSEMBLED DRAWINGS .......................................................... - 18 -

11.SPECIFICATION .............................................................................................................. - 22 -

12.MOTOR PROTECTION .................................................................................................... - 23 -

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
1.Introduction
Thank you for your purchasing of the Ring Compressor.

It is required for the Ring Compressor for give full play to its performance, for preventing troubles from
occurring and for continuing its satisfactory operation for a long period not only to maintain and inspect
it after putting it into service but also to handle it properly in every stage after its delivery until its actual
operation.
This instruction manual illustrates the essential items for handling the Ring Compressor.

If you find any question, please inquire of our special agent, dealer or business office about it.

2.Warnings for safety


• Read this instruction manual and the other attached documents carefully before you use (install,
transport, maintain, inspect etc.) the Ring Compressor and then use it properly. Acquire first the
machine knowledge, safety information and all warning items and use the machine.
Keep this instruction manual at the place, where can be accessed by the persons, who use it.
• The ranks for safety items are classified into dangers and warnings and described in this instruction
manual.

Danger
: those items, for which the possibility of human DEATH and
HEAVY INJURY are feared, if they are mishandles.

: those items, for which hazardous condition may occur and

Warning MEDIUM HAZARD and SLIGHT INJURY are feared and/or


material damage are feared, if they are mishandles.

Even those items marked with Warning may lead to serious results depending upon the
situation.

As every item describes serious contents, be sure to keep it always.


Furthermore, the following symbols are applied according to necessity in this instruction manual, so
that the essential points of indication can be grasped at a glance.

Symbol Meaning Symbol Meaning

Notification of a general Do not touch!


prohibition

Always connect a Take care of ignition!


protective earthing
terminal!

Take care of an electrical Take care of a high


shock! temperature!

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Danger
• The works of transport, installation, piping, wiring, operation, control, maintenance and
inspection may only be executed by the experts, who are well skilled of handling the
Ring Compressor. Otherwise, an ELECTRIC SHOCK, an INJURY or a FIRE is feared.
• Hot line works are forbidden. Work always with the power supply switched off.
Otherwise, an ELECTRIC SHOCK or a FIRE is feared.
General
• Do not use the Ring Compressor in an explosive atmosphere.
Otherwise, an INJURY or a FIRE is feared.
• Incorrect operation may lead to an FIRE, because of the characteristics of the power
cable.

• Ground the protective earthing terminal surely. Use the wiring of AWG 14(2.1mm2) for
VFZ 40 to 60 type, the wiring of AWG 12(3.3mm2) for VFZ 70 type, the wiring of AWG
10(5.3mm2) for VFZ 80 to 90 type, and ground it near the product.
Installation, Otherwise, an ELECTRIC SHOCK or a FIRE is feared.
Adjustment
• In the Ring Compressor is used as mounted on a ceiling or a wall, its fall is feared
depending on its mounting condition. Observe the catalog or instruction manual for the
details of usable range. An INJURY due to a FIRE is feared.

• Connect it to the power supply cable according to the wiring diagram within terminal
box and the instruction manual. An ELECTRIC SHOCK or a FIRE due to incorrect
connection is feared.
• Use it always at the voltage and frequency indicated in the nameplate on its main body.
Piping, A BURNOUT or a FIRE is feared.
Wiring
• Do not bend, stretch or pinch the power supply cable and the lead wire for the Ring
Compressor by force. An ELECTRIC SHOCK or a FIRE is feared.
• Restore the cover for terminal box to the original position after completion of every
work. Otherwise, an ELECTRIC SHOCK is feared.

• Never access or touch any rotating body (cooling fan etc.) during running. A CATCH-IN
on an INJURY is feared.
• Switch off the power supply always in case of power failure. An INJURY is feared due
to sudden work of the machine at restoration of power supply.
• Switch off the power supply always when the Ring Compressor is stopped because the
Operation
protection unit belonging to it worked. An INJURY is feared due to sudden work of Ring
Compressor at recovery of the protection unit.
• Do not run the Ring Compressor at the frequency exceeding 60Hz (50Hz* for models
dedicated to 50Hz*). Otherwise, it may lead to a BURN, a FIRE, DAMAGE, or an
INJURY. ※50 Hz operation is not covered by UL.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Warning
• Do not use the Ring Compressor out of the specifications described in the
nameplate, catalog and instruction manual. An ELECTRIC SHOCK, an INJURY or
DAMAGE is feared.
• Do not use the damaged Ring Compressor. An ELECTRIC SHOCK, an INJURY or
a FIRE is feared.
General
• Do not insert any foreign material or finger into the opening (opening in fan cover,
admission and discharge ports) of Ring Compressor. An ELECTRIC SHOCK an
INJURY or DAMAGE is feared.
• We take no responsibility for modification by the customer, as they are out of the
scope of our responsibility.

• Take full care of fall and tumbling down during transportation. An INJURY is feared.
• Lift up the Ring Compressor equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Compressor on a
machine, do not lift up the entire machine using the mounted hanger bolt.
Verify the mass of motor based in the nameplate, package box, outline drawing,
catalog or the like before lifting it and do not lift any more mass than the rated load
of lifting tool. The gravity center of the Ring Compressor is located at motor side,
therefore, the Ring Compressor inclines to one side during lift-up.
Exert tension gradually on the wire and do not lift up suddenly.
Transportation This lift-up work may only be executed by the qualified workers. Do not stay under
the Ring Compressor during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of
these cases.
• When lifting the Ring Compressor without a hanger bolt, pay attention to its weight.
Do not allow a single person to lift the product heavier than 15kg. Failure to
observe this may cause an INJURY.
• Ambient temperature should be kept –20℃~+50℃ during transportation.

• Open the package after verifying the top and bottom of product. An INJURY is
feared.
• Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
Opening the
Package • Verify if the product is just the ordered one. An INJURY, DAMAGE or a FIRE due
to use of the incorrect product is feared.
• Verify if no part of the product is damaged during transportation and if all fastening
parts including bolts and nuts are securely tightened.

• Never place any inflammable material around the Ring Compressor. A FIRE is
feared.
• Do not place any obstacle against ventilation around the Ring Compressor. A
BURN or a FIRE caused by abnormal heating due to disturbed cooling is feared.
• Fasten the foundation bolts surely.
Insufficient fastening may cause an INJURY and DAMAGE due to shift of the Ring
Installation,
Compressor.
Adjustment
• Never get on or hang on the Ring Compressor. An INJURY is feared.
• Ring Compressor shell be always mounted on suitable place in order to see its
nameplate easily and do not put any obstacle in front of it.
Do not dismount the nameplate.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Warning
• Construct the piping and wiring according to the technical standard for electrical
equipment and the internal wiring provisions. A BURNOUT or a FIRE is feared.
• For wiring to the terminal base in terminal box, fasten the terminal screws with a
torque of 1.0 to 1.3 N・m. Otherwise, DAMAGE of the terminal box is feared.

Piping, • For measuring the insulation resistance, do not touch the terminal. An ELECTRIC
Wiring SHOCK is feared.
• No protection unit belongs to the Ring Compressor except for some models. The
installing of overcurrent protection unit is obliged based upon the technical
standard for electrical equipment. For preventing a FIRE and DAMAGE due to a
motor burnout, we recommend to install the protection unit other then overcurrent
protection units (including a ground fault interrupter) based upon consulting with us.

• If any abnormality occurs, stop the operation immediately and switch off the power
supply. An ELECTRIC SHOCK an INJURY or a FIRE is feared.
• The Ring Compressor becomes considerably hot during its operation. Take care
Operation not to touch it by your hand or body. A BURN is feared.
• Do not insert your finger or any others material into the opening of Ring
Compressor. An ELECTRIC SHOCK an INJURY or FIRE is feared.
• Wear stopples during operation to shut the big noise.

• Do not touch the terminal for measuring the insulation resistance. An ELECTRIC
SHOCK is feared.
• The Ring Compressor becomes considerably hot during its operation. Take care
Maintenance
not to touch by your finger and body. A BURN is feared.
, Inspection
• Take care, if you use a solvent or the like for cleaning the Ring Compressor. A
POISONING is feared. Further, the use of thinner or benzene may cause
discoloring or exfoliation of coating on the Ring Compressor.

Disassembly, • The repair, disassembling and modification shall be executed only by experts. An
Repair, INJURY due to the edge of Impeller or key groove, an ELECTRIC SHOCK or a
Modification FIRE is feared.

Disposal • Handle the Ring Compressor as a general industrial waste, when it is be disposed.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
3.Package Opening and Product Verification
3.1 When the Ring Compressor has been delivered, verify the following points.

Warning
1. Verify the top and the bottom of product and open the package.
Otherwise, an INJURY is feared.
2. Open the wooden frame package taking care of the used nails. Wear glove when
opening the wooden package. An INJURY is feared.
3. Verify if the delivered product is just the ordered one.
(Check the output voltage, frequency, model etc. with the description on face plate.)
An INJURY, DAMAGE or a FIRE is feared, if an incorrect product is used.
4. Verify if any part is damaged and if any bolt or nut is loosened during the transport.

3.2 Location of name plate, warning labels and electric shock warning labels
The figure below shows the locations of name plate, warning labels and electric shock warning
labels.

A B

Electric shock Electric shock


Warning label Warning label

Warning label

Nameplate
Nameplate

Electric shock
Warning label

Nameplate

Warning label

Warning label
View from A View from B

VFZ601~701A-7W(5W) VFZ801~VFZ901A-7W(5W)
VFZ401~VFZ501A-7W(5W)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
4.Transport
Take care of the following points for transporting the Ring Compressor.

Warning
1. Take full care of fall and tumbling down during transportation. An INJURY is feared.
2. Lift up the Ring Compressor equipped with a hanger bolt always after getting rid of
loosening of the hanger bolt. But after mounting the Ring Compressor on a machine,
do not lift up the entire machine using the mounted hanger bolt.
Verify the mass of motor based in the nameplate, package box, outline drawing,
catalog or the like before lifting it and do not lift any more mass than the rated load of
lifting tool. The gravity center of the Ring Compressor is located at motor side,
therefore, the Ring Compressor inclines to one side during lift-up.
Exert tension gradually on the wire and do not lift up suddenly.
This lift-up work may only be executed by the qualified workers. Do not stay under
the Ring Compressor during the lifting work.
An INJURY or FIRE caused by FALL or TUMBLING DOWN is feared for all of these
cases.
3. When lifting the Ring Compressor without a hanger bolt, pay attention to its weight.
Do not allow a single person to lift the product heavier than 15kg. Failure to observe
this may cause an INJURY.

Lifting method of the Ring Compressor


1. Use one hanger bolt 2.Use two hanger bolts In case of terminal box is located 45°

(VFZ501~VFZ701,VFC805) (VFZ801, VFZ901) (VFZ801, VFZ901)

Gravity Center Move hanger bolt

5.Safekeeping
Take care of following points for safekeeping the Ring Compressor or suspending its operation for a
long period.

5.1 For safekeeping in the packed.


Keep the Ring Compressor in an indoor dry place (Ambient temperature: -20℃~+50℃). Do not
keep it on such a place, as is exposed to water or dust, or with vibration, or place it on a bare
ground directly.
5.2 For keeping it in the installed condition.
(a) Cover the entire Ring Compressor with a sheet for protecting it from invasion of moisture
foreign materials.
(b) Keep the Ring Compressor with its hanger bolt mounted. If it is kept with the hanger bolt
dismounted, water may sometimes invade into through the screw hole.
(c) Run the Ring Compressor for some minutes keeping it and every 3 months, for protecting the
bearings from rusting.
(d) If the operation of Ring Compressor is suspended for a long period, measure the insulation
resistance of its winding every 6 months and verify that it is kept at higher than 1 MΩ. If the
resistance is not higher then 1 MΩ at normal temperature, such measures are required as to
dry the winding.
(e) Keep the Ring Compressor in an indoor dry place (Ambient temperature: -20℃~+50℃).

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
6.Name of parts Casing Gutter
End cover

Terminal box Motor

Fan cover

Cooling fan
Casing cover

Impeller

Suction port
Discharge port
Silencer Middle bracket (Cross section of VFZ601A-7W)

7.Installation , Piping and Wiring


7.1 Take care of the following points for installing and adjusting the Ring Compressor.

Danger
1. Ground the protective earthing terminal surely. Use the wiring of AWG 14(2.1mm2) for
VFZ 40 to 60 type, the wiring of AWG 12(3.3mm2) for VFZ 70 type, the wiring of AWG
10(5.3mm2) for VFZ 80 to 90 type, and ground it near the product. An ELECTRIC
SHOCK or a FIRE is feared.
2. In case of using the Ring Compressor mounted on a ceiling or wall, its fall is feared
depending upon the condition. Follow the catalog or instruction manual for details of
usable range.
INJURY caused by its FALL is feared.

Warning
3. Never place any inflammable object around the Ring Compressor.
A FIRE is feared.
4. Do not place any obstacle, which disturbs the ventilation, around the Ring
Compressor.
A BURN or a FIRE caused by abnormal heating is feared, due to the disturbed
ventilation.
5. Fasten the foundation bolts surely before starting the operation. An INJURY or
DAMAGE due to shift of the Ring Compressor is feared, if the fastening is insufficient.
6. Never step on or hang from the Ring Compressor.
An INJURY is feared.
7. Make the nameplate for the Ring Compressor always easily legible and do not place
any obstacle in front of it. Do not dismount the face plate.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
7.2 Take care of the following ranges for the installation site and the gas to be transported.

Warning
1. Outdoor/indoor: Install at an indoor site, which is exposed to no wind and rain
Otherwise, an ELECTRIC SHOCK or a FAULT is feared.

2. Ambient temp./ Use it in the range from -10 to 40℃. Otherwise, shortening of life
transported gas: and a FAULT is feared. The transported gas should be standard
air. (No freezing is allowed.)
3. Relative humidity / Use relative humidity in 80% or less and 1000m above sea level
altitude: or less. Shortening of life or FAULT is feared.

4. Atmosphere / If can neither be used in a place, where any such corrosive liquid
transported gas: or gas as an acid or an alkali or any inflammable or explosive
gas exists, nor trans port such material. A FIRE, a FAULT or an
INJURY is feared.
5. Dusts: Evade a place, where a lot of dusts, wastes or thread chips exist.
If inevitable, clean the dusts and wastes adhered in the Ring
compressor regularly.
A FIRE or a FAULT is feared
6. Ventilation: Select a well ventilated place. It shell not be used in a closed
room or in a case. A FIRE, a BURN or a FAULT is feared.

7. Ambient air: Evade a narrow place, for the convenience of maintenance and
inspection.

8. Vibration: Select a place, where no external vibration is added to the


compressor. If inevitable, take anti-vibration measures for
protecting from addition of vibration the Ring compressor. A
FAULT, DAMAGE or an INJURY is feared. The value in Figure
1 is recommended as the tolerable vibration value.

Size and tightening torque (recommended value) of the anchor bolt

Anchor hole Bolt size Tightening torque

mm mm N・m

φ12 M10 23.4


φ15 M12 41.3
φ19 M16 105
※ Bolt materials are
recommended values in case of
SS, SWRM
(Figure 1)

9. Install the Ring Compressor so as to be used in horizontal shaft condition. For installing it in
vertical or slant shaft condition, install it so that its compressor side lies under its motor side
(Figure 2). ※VFZ701~VFZ901: Horizontal shaft condition only
<Good!> <No good!>

① ② ③ ④ ⑤

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
10. The tone quality of compressor noise in this product changes depending on the Air flow rate,
pressure and fully closed suction operation.

7.3 Observe the following points in piping work and wiring work.

Danger
1. Connect it to the power supply cable according to the wiring diagram within terminal box
and the instruction manual. An ELECTRIC SHOCK or a FIRE due to incorrect
connection is feared.
2. Use it always at the voltage and frequency indicated in the nameplate on its main body.
A BURNOUT or a FIRE is feared.
3. Do not bend, stretch or pinch the power supply cable and the lead wire for the Ring
Compressor by force. An ELECTRIC SHOCK or a FIRE is feared.
4. Restore the cover for terminal box to the original position after completion of every work.
Otherwise, an ELECTRIC SHOCK is feared.

Warning
5. Ground the protective earthing terminal surely.
An ELECTRIC SHOCK or a FIRE is feared.
6. Construct the piping and wiring according to the technical standard for electrical
equipment and the internal wiring provisions. A BURNOUT or a FIRE is feared.
7. For wiring to the terminal base in terminal box, fasten the terminal screws with a torque
of 1.0 to 1.3 N・m. Otherwise, DAMAGE of the terminal box is feared.
8. For measuring the insulation resistance, do not touch the terminal. An ELECTRIC
SHOCK is feared.
9. No protection unit belongs to the Ring Compressor except for some models. The
installing of overcurrent protection unit is obliged based upon the technical standard for
electrical equipment. For preventing a FIRE and DAMAGE due to a motor burnout, we
recommend to install the protection unit other then overcurrent protection units (including
a ground fault interrupter) based upon consulting with us.

10. As the motor load (current) changes depending upon the air flow used by the Ring Compressor,
refer to the characteristics curve for setting the wiring capacity and protection relay.

11. Use such pipes as PVC-pipes, gas pipes, flexible hoses etc., which can hold the Ring
Compressor pressure and hoses other then metallic one for discharge side, use those once,
which have a sufficient high-temperature resistance.
Lay piping so surely as to have no leakage (Figure 3).

Piping for suction port and discharge port.

Type for companion flanges


(Type from VFZ40 to VFZ90) ※ In case of piping to companion flanges,
Companion companion flanges must be remove form the Ring
Compressor before piping, it should be assembled
flange
after piping. Take care of the breakage by tighten
pipes too much.

Plastic or steel pipe

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Piping for Ring Compressor

Ideally, use pipes having the same Economical for high pressure
diameter as standard pipes. and small Air flow, as small
pipes may be used.

Use large diameter pipes for long


piping having many bends

Pipe joint Construct piping surely with no leakage.


Pressure and Air flow will be reduced by
Pipe support leakage.

Caution : Arrange pipe-supports properly, so that no self


weight and external load concentrate on pipe (Figure 3)
connections.

12. Do not allow any foreign material to intrude into the compressor.

13. The rotation direction shall be the arrow direction on the casing. The rotation direction can be
seen at the shaft end at counter-compressor side and it is also correct, if the wind direction
coincides with the IN and OUT indicated at the pipe connection port. Reverse rotation is allowed,
although the performance is reduced.

14. Connect the power cables by using gland or electrical conduit at wiring hole of the terminal box to
protect dust, foreign objects, water and etc. into the terminal box inside. Do not remove the
unused rubber bushes of VFZ501~VFZ901. Do not use the rubber bushes to wiring.

15. Take care of edge of wiring holes at the terminal box. An INJURY is feared.

Recommended gland VFZ401~VFZ701: Multi hole type seal connector


VFZ801, VFZ901: Seal connector

16. Wire the power cables with motor terminals surely according to wiring figure in the terminal box or
Figure 4.

Model VFZ401~VFZ601-7W VFZ701~VFZ901-7W, VFC805A-7WS

Wires 11 wires 11 wires

Connecting
method

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Model VFZ401~VFZ901-5W, VFC805A-5WS

Wires 5 wires

Connecting
method

(Figure 4) Wiring diagram

17. Limit the fluctuations of the supply voltage within ±10% of the rated voltage, and also limit the
fluctuations of the frequency between –5% and +3% of the rated value. Although you can run the
Ring Compressor in these ranges, avoid continuous operation if the voltage is not within ±5% of
the rated value or if the frequency is not within ±2% of the rated value. Even if the power
fluctuations fall within the allowable ranges, the Ring Compressor characteristics and motor
characteristics may differ from those at the rated voltage and frequency.

18. Before operating the Ring Compressor, check the following points again.
・ Check that the equipment is correctly wired.
・ Check that the equipment is securely grounded.
・ Check that an appropriate ground fault interrupter and an overload protection device are
installed.
・ Check that none of the three terminals of the motor has come loose or disconnected.
In case of running the motor with connection of only two terminals, it may cause an
open-phase operation, thus leading to motor burnout.

8.Operation
Verify the following points for operating the Ring Compressor.

Danger
1. Never access or touch the rotating body (cooling fan etc.) during running. CATCH-IN
or INJURY is feared.
2. Turn the power supply switch off in case of power failure.
INJURY is feared, when the machine runs suddenly at the power restoration.
3. Be sure to turn the power supply switch off, in the Ring Compressor has been stopped
because the attached protection unit has been activated. An INJURY is feared, as the
machine may run suddenly at the power restoration.
4. Do not run the Ring Compressor at the frequency exceeding 60Hz (50Hz for models
dedicated to 50Hz). Otherwise, it may lead to a BURN, a FIRE, DAMAGE, or an
INJURY. ※50 Hz operation is not covered by UL.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Danger
5. If any abnormality occurs, stop the operation immediately and turn the power supply
switch off. An ELECTRIC SHOCK, an INJURY or a FIRE is feared.
6. During operation the Ring Compressor, it becomes considerably hot. Take care not to
touch by your hand or body. A BURN is feared.
7. During its operation, do not insert your finger or any other object into the opening (fan
cover, admission and discharge ports etc.) of the Ring Compressor.
An ELECTRIC SHOCK, an INJURY or a FIRE is feared.
8. If the Ring Compressor (VFZ401A and larger) is operated with the discharge side
closed, the motor and compressor temperature rises drastically and its distortion or
damage after long time operation is feared.
9. If the Ring Compressor is operated at a wind flow rate not more then continuous
operation range, the motor and compressor temperature rises drastically and its
distortion or damage is feared, if the operation is continued for along time.
10. The temperature of the air passing through the Ring Compressor rises. Especially it
reaches a high temperature at a nearly closed condition. Take care not to touch it by
your hand or body. A BURN is feared. Figure 7 shows the temperature rise. Figure 8
shows the high temperature part of the Ring Compressor.
11. During its operation, the Ring Compressor and discharged air will reach a
considerably high temperature. Do not use it in a narrow closed room. A BURN, a
FIRE or DAMAGE is feared. (Inquire of us, if you use it in closed operation.)

12. The Ring Compressor will be continuously at within the operation range shown on the wind flow
rate to static pressure curve (shown in the catalog). This operation range is so wide that the
machine can be operated at nearly closed pressure but, if you operate it at high pressure,
especially take care not to exceed the operation range. If you must operate it at closed condition,
arrange a bypass hole on the way, so that a more wind than required range flows through the
compressor even if the suction port is closes (Figure 5).

For using discharge side closed

Bypass hole
Valve

Piping

(Figure 5)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
13. For using air intermittently, the switching by means of a valve is recommended rather than the
switching on and off of the motor (Figure 6). The standard for start and stop frequency of Ring
Compressor shall be not higher than the values in table.
Product(Load)
Valve
Release
Valve

Suction
Blow

(Suction)
(Blow)

(Figure 6)
Switch suction and blow using the valve.

Tolerable start/stop frequency for Ring Compressor[Sw/Hr]


Model Value for frequency of 50/60Hz
VFZ401 – VFZ601 20/15
VFZ701 – VFZ901 15/10
*1 switch:one cycle of ON and OFF
*2 50 Hz operation is not covered by UL.
14. Connect the power cables by using gland or electrical conduit at wiring hole of the terminal box to
protect dust, foreign objects, water and etc. into the terminal box inside. Do not remove the
unused rubber bushes of VFZ501~VFZ901. Do not use the rubber bushes to wiring.

15. Remove any solid object, dust, thread chip, water drop or the like before entering into the Ring
Compressor. Even if make no dust be sucked directly, take measures not to suck any dust
staying around by mistake. Use of the dust staying around by mistake. Use of the dust collection
sack in a vacuum cleaner or the like is recommended.
Also, it is recommended to use a filter having considerably large space. Remove sometimes the
dust collected in the filter. It may also be possible to make the dust blow off by reversing the Ring
Compressor, if it is possible.

16. If dusts adhered inside and outside of the compressor (especially in the cooling air path for
cooling fan cover), remove them. If adhered dusts increase, it causes such troubles as a
temperature rise, a sink of wind flow rate and an increase vibration.

17. As the motor load (current) changes depending upon the air flow used by the Ring Compressor,
refer to the characteristics curve for setting the wiring capacity and protection relay.

18. The bearing and silencer are consumables and need to be changed when their lives are arrived.
Depending on the environment, in which the machine was used, the Impeller, casing, casing
cover, and wire net are also included in consumables. (Please notice discharge and suction
material is different from VFZ50’s and VFZ60’s silencers when you exchange them.)

Intervals for inspection and exchange of consumables


Part name Inspection/exchange interval *Standard for use in a standard environment.
They may be shorter depending on the environment.
Bearing 2 years

Silencer 2 years

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Table of bearing
Bearing
Model Grease
Load side No-load side

VFZ401 6204ZZCM 6203ZZCM Urea

VFZ501 6206ZZC3 6205ZZCM Urea

VFZ601 6206ZZC3 6205ZZCM Urea

VFZ701 6306ZZC3 6206ZZCM Urea

VFZ801 6308ZZC3 6207ZZCM Urea

VFZ901 6308ZZC3 6306ZZCM Urea

Temperature RISE K
Temperature RISE K

Air flow rate ( m3/min ) Air flow rate ( m3/min )


(Figure 7) Discharged air-temperature rise curve
※50 Hz operation is not covered by UL.

Motor
Casing

Casing cover
Silencer
*The temperature of the air passing through the
Ring Compressor rises. Especially it reaches
a high temperature at a nearly closed
condition.
(Figure 8)High temperature part of the Ring Compressor

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
19. Confirm below items at test running, if inverter is applied for the Ring Compressor operation.
・Resonance is feared by install condition of the Ring Compressor. Avoid the frequency of the
resonance
・Vibration and noise become bigger by using inverter. Stop the operation immediately, if abnormal
temperature rise or vibration occurs.
・Do not run the Ring Compressor at the frequency exceeding 60Hz (50 Hz* for models dedicated
to 50 Hz*). ※50 Hz operation is not covered by UL.
Otherwise, the motor may burn out, or the main body of the compressor may be damaged.
・For the frequency of the startups and shutdowns in the operation with a inverter, refer to the table
below.

Tolerable start/stop frequency for Ring Compressor[Sw/Hr]


Model Value for frequency of 50/60Hz
VFZ401 – VFZ601 20/15
VFZ701 – VFZ901 15/10
*1 switch:one cycle of ON and OFF
*2 50 Hz operation is not covered by UL.

9.Faults and Countermeasures


In case of occurrence of any fault in the Ring Compressor, handle it properly referring to Table 1
“Fault States of Ring Compressor and Countermeasures” (page 17) and taking care of the following
points.

Warning
1. Always only the expert shall investigate, repair, disassemble and modify the fault. An
INJURY due to the Impeller edge or key groove, an ELCTRIC SHOCK or a FIRE is
feared.
2. If the Ring Compressor must be abandoned as the result of investigation in a rare
possibility, dispose it as a general industrial waste.

3. If the investigation result shows that the machine cannot be easily repaired, if you will
request any spare part or you have any trouble, contact our agent, dealer or business
office at any time. In case of contacting us, please verify following items in advance:
(a) Model indicated in the nameplate,
(b) SER. No.,
(c) Details of the fault,
(d) Name of faulty part, name of spare parts,
(e) Required quantity and
(f) Kind of gas to be transported (e.g. Air)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Table - 1 Fault States of Ring Compressor and Countermeasures

States of Fault Causes Countermeasures


Switch-contact fault Repair switch-contact.
Fuse blown Replace it.
One phase of power supply Replace it.
connection wires disconnected.
Whining sound One phase of stator coils Request factory to repair it.
disconnected.

Does not Stator and rotor come into contact Replace bearing.
rotate due to bearing fault.
Foreign material involved in blades. Remove it.
Power failure Consult with utility company.
2 phases of power supply connection Replace them.
No sound wires disconnected.
2 phases of stator coils disconnected. Request factory to repair them.

Switch fault Replace or replace it.


Fuse blown Short-circuit in circuit Repair or replace it.
Power supply voltage fell Consult with utility company.
Motor overheated Single phase operation Request factory to repair it.
Impeller rubbing Adjust wheel.
1 phase short circuit in stator coils. Request factory to repair it.
Whining sound Uneven space between stator and Request factory to repair it.
rotor.
Blade wheel rubbing Adjust it.
Rotates
Blade damaged due to foreign Request factory to repair it.
Abnormal noise
material.
Bearing fault Replace it.
Leakage in piping. Fasten tightly.

Motor rotates but Piping blocked Ventilate sufficiently.


fan works Reverse rotation direction Correct connection (2 out of 3
improperly. wires).
Closure equipment fault Replace it.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
10.Parts List and Disassembled Drawings
The Parts List of Ring Compressor is shown below.
The Parts No. in Parts List corresponds to those in Disassembled Drawings.
Caution: Some parts are not used for some machine models.

Part No. Name of Part Part No. Name of Part Part No. Name of Part

1-1 Casing cover 3-4 Bearing at counter-driving side 4-28 Cap

1-2 Bolt (for Casing cover) 3-5 Bearing at driving side 5-1 Terminal box

1-3 Impeller 3-6 Spacer 5-2 Packing (for Terminal box)

2-1 Casing 3-7 Press ring 5-3 Terminal box cover

2-2 Bolt (for Casing) 3-8 Bolt (for fastening Fan wheel) 5-6 Packing (for Terminal box cover)

2-3 Spring washer 3-9 Claw washer 5-7 Bolt (for Terminal box cover)

2-4 End cover 3-11 Key (for Fan Wheel) 5-8 Bush (for Terminal box)

Bolt
2-5 Bolt (for End cover) 3-12 Motor cooler fan 5-9
(for Protective earthing terminal)

Bush
2-6 Spring washer 3-13 Bolt (for Motor cooler fan) 5-20
(for Leader mouth for Terminal box)

2-7 Silencer (1 set) 4-1 Frame/Stator assembly 5-21 Bolt (for Motor)

2-7-1 Silencer (Suction side) 4-4 Shield at counter-driving side 5-22 Nut (for Motor)

2-7-2 Silencer (Discharge side) 4-5 Waved washer

2-8 Flange 4-7 Bolt (for Shield)

2-9 Bolt (for Flange) 4-8 Cooler fan cover

2-10 Filter 4-9 Bolt (for Cooler fan cover)

2-15 Silencer Retaining Net 4-13 Bolt (Shield, frame)

2-16 Silencer box 4-14 Nut (Shield, frame)

Spring washer
2-17 Bolt (for Silencer box) 4-15
(Shield, frame)

2-18 Hanger bolt 4-16 Middle bracket

Spring washer
2-20 4-17 Bolt (Middle bracket, frame)
(for Silencer box)

3-1 Shaft/Rotor assembly 4-18 Spring washer

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Disassembled VFZ401A-7W(5W) – VFZ501A-7W(5W)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Disassembled VFZ601A-7W(5W)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
Motor part of VFZ801A, VFZ901A
Disassembled VFZ701A-7W(5W)~VFZ901A-7W(5W)

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
11.Specification
Deliv ery c harac t er
Maximum value Rated value
MInimum
Voltage Frequency Output(*) Static Static
Model Current(*) Pressure(*) Air quantity(*) air quantity
【V】 【Hz】 pressure air quantity
【A】
3 3 3
【HP】 【kW】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【SCFM】 【 m /min】

VFZ401A-7W 1.3 0.95 3.8-3.5/1.8 60 15.3 89 2.6 19 4.90 68 1.95 7 0.2


VFZ501A-7W 2.7 2 7.8-7.4/3.7 80 20.3 135 3.9 27 6.86 104 3 45 1.3
VFZ601A-7W 5 3.7 13.2-12.1/6.1 112 28.5 173 5 39 9.81 153 4.4 56 1.6

VFZ701A-7W 208-230/ 60 6.7 5 17.6-16.2/8.1 105 26.7 217 6.3 39 9.81 198 5.7 87 2.5
460
VFZ801A-7W 11 8 27.8-25.2/12.6 115 29.2 379 10.9 39 9.81 295 8.5 132 3.8
VFC805A-7WS 11 8 27.8-25.2/12.6 115 29.2 379 10.9 39 9.81 295 8.5 132 3.8
VFZ901A-7W 15 11 39.1-37.8/18.9 90-94/104 23.0-24.0/26.5 574 16.5 58 14.7 375 10.8 191 5.5
VFZ401A-5W 1.3 0.95 1.4 60 15.3 89 2.6 19 4.90 68 1.95 7 0.2
VFZ501A-5W 2.7 2 3.0 80 20.3 135 3.9 27 6.86 104 3 45 1.3
VFZ601A-5W 5 3.7 4.9 112 28.5 173 5 39 9.81 153 4.4 56 1.6

VFZ501A-5W 60 6.7 5 6.5 105 26.7 217 6.3 39 9.81 198 5.7 87 2.5
575
VFZ801A-5W 11 8 10.1 115 29.2 379 10.9 39 9.81 295 8.5 132 3.8
VFC805A-5WS 11 8 10.1 115 29.2 379 10.9 39 9.81 295 8.5 132 3.8
VFZ901A-5W 15 11 15.2 100 25.4 574 16.5 58 14.7 375 10.8 191 5.5

Suc t ion c harac ter


Maximum value Approximate
MInimum Noise Starting
Insulation Suction/delivery mass
Model Output Pressure air quantity value current
Current class bore diameter
【dB(A)】 【A】
【A】
3
【HP】 【kW】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【 kg】 【 lbs 】

1
VFZ401A-7W 1.1 0.85 3.3-3.2/1.6 53 12.9 0 0 F 69.5 NPSC 1 /2 33.3-36.0/18.0 21.0 46
VFZ501A-7W 2.4 1.8 6.9-6.7/3.4 82 20.8 0 0 F 74.5 NPSC 11/2 69-76/38 35.0 77
VFZ601A-7W 4.4 3.3 11.2-10.8/5.4 95 23.6 0 0 F 74.5 NPSC 2 119-132/66 49.0 108
VFZ701A-7W 6.4 4.8 16.2-15.3/7.7 99 25.1 0 0 F 79.5 NPSC 2 189-210/105 61.0 134
VFZ801A-7W 10.4 7.8 23.0-22.1/11.0 108 26.6 0 0 F 81 NPSC 21/2 252-270/135 95.5 211
VFC805A-7WS 10.4 7.8 23.0-22.1/11.0 108 26.6 0 0 F 81 NPSC 21/2 252-270/135 130.0 287
VFZ901A-7W 13.7 10.3 33.9-33.7/17.0 85 21.5 146 4.2 F 83 NPSC 3 456-500/250 117.5 259
VFZ401A-5W 0.85 0.85 1.2 53 12.9 0 0 F 69.5 NPSC 11/2 28.8 21.0 46
VFZ501A-5W 1.8 1.8 2.7 82 20.8 0 0 F 74.5 NPSC 11/2 30 35.0 77
VFZ601A-5W 3.3 3.3 4.2 95 23.6 0 0 F 74.5 NPSC 2 53 49.0 108
VFZ501A-5W 4.8 4.8 6.0 99 25.1 0 0 F 79.5 NPSC 2 84 61.0 134
VFZ801A-5W 7.8 7.8 8.4 108 26.6 0 0 F 81 NPSC 21/2 108 95.5 211
VFC805A-5WS 7.8 7.8 8.4 108 26.6 0 0 F 81 NPSC 21/2 108 130.0 287
VFZ901A-5W 10.3 10.3 13.2 85 21.5 146 4.2 F 83 NPSC 3 200 117.5 259

The noise is the value at a position of 1.5m in an open state.

The values with (*)mark are specified on nameplate.

The maximum static pressure of the delivery character is the value near the discharge port, and it is the value of

the state where the temperature is saturated.

Deliv ery c harac t er


Maximum value
MInimum
Voltage Frequency Output Pressure Air quantity air quantity
Model
【V】 【Hz】 Current
【A 】 3 3
【HP 】 【kW 】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【SCFM】 【 m /min】

VFZ401A-7W 0.8 0.6 3.0/1.5 42 10.4 74 2 0 0


VFZ501A-7W 1.9 1.4 6.5/3.8 60 14.7 114 3.4 7 0.2
VFZ601A-7W 3.6 2.7 10.6/5.3 85 21.6 145 4.2 28 0.8
VFZ701A-7W 3φ 4.4 3.3 13.4/6.7 84 21.4 179 5.2 38 1.1
200/400 50 (※)
VFZ801A-7W 7.3 5.5 20.5/10.3 85 21.6 318 8.7 63 1.8
VFC805A-7WS 7.3 5.5 20.5/10.3 85 21.6 318 8.7 63 1.8
VFZ901A-7W 9.3 7.0 39.7/19.9 78 19.8 472 13 90 2.6

S uc t ion c harac t er
Maximum value Approximate
MInimum Noise Starting
Insulation Suction/delivery mass
Model Output Pressure air quantity value current
Current class bore diameter
【dB(A)】 【A】
【A】 3
【HP】 【kW 】 【in.H2 0】 【 kPa】 【SCFM】 【 m /min】 【 kg】 【 lbs 】
1
VFZ401A-7W 0.71 0.53 2.7/1.3 39 9.4 0 0 F 65.5 NPSC 1 /2 32.5/16.3 21.0 46
VFZ501A-7W 1.7 1.3 6.0/3.0 55 13.7 0 0 F 70.5 NPSC 11/2 71/35.5 35.0 77
VFZ601A-7W 3.1 2.3 9.8/4.9 72 18.2 0 0 F 70.0 NPSC 2 120/60 49.0 108
VFZ701A-7W 4.1 3.1 12.7/6.3 78 18.3 0 0 F 75.0 NPSC 2 195/97.5 61.0 134
VFZ801A-7W 6.9 5.2 18.8/9.4 88 21.6 0 0 F 78.0 NPSC 21/2 268/134 95.5 211
VFC805A-7WS 6.9 5.2 18.8/9.4 88 21.6 0 0 F 78.0 NPSC 21/2 268/134 130.0 287
VFZ901A-7W 9.3 7 24.5/12.2 63 19.7 111 3.2 F 79.5 NPSC 3 438/219 117.5 259

The noise is the value at a position of 1.5m in an open state.


(※)50 Hz operation is not covered by UL.

Jamieson Equipment Company


www.jamiesonequipment.com
toll free 800.875.0280
12.Motor Protection
The overload will cause the protector (MMS) to operate. Please set the protector (MMS) with setting
current. UL evaluation test was carried out at the protector (MMS).
Protector circuits other than MMS are listed as recommended. Please judge the use on the final
product side.(Figure 9)

*1 Voltage to be connected to the recommended


equipment is AC200V

*2 Specification of the thermal protector


Terminal marking : P1,P2
Open temperature : 135℃
Close temperature : 86℃
Maximum current : AC250V 7A, AC125V 10A

Recommended Equipment *3
Blower Motor Controllers, Manual *4 Magnetic Contactors Electromagnetic Relay Push button switches
Model Voltage(V) Model Setting current File No. Model Specification File No. Model Specification File No. Model File No.
208 BM3RSB-6P3 4A E163944 SC-03 200V 7.8A E42419 HH52 200V E42419 AR22 E44592(UL)
VFZ401A-7W 230 BM3RSB-6P3 4A SC-03 200V 7.8A LR20479(CSA)
460 BM3RSB-2P5 2A SC-03 200V 7.8A
208 BM3RSB-010 8A SC-0 200V 11A
VFZ501A-7W 230 BM3RSB-010 8A SC-0 200V 11A
460 BM3RSB-004 4A SC-03 200V 7.8A
208 BM3RSB-016 14A SC-4-0 200V 17.5A
VFZ601A-7W 230 BM3RSB-016 14A SC-4-0 200V 17.5A
460 BM3RSB-010 7A SC-03 200V 7.8A
208 BM3RSB-025 21A SC-N1 200V 25.3A
VFZ701A-7W 230 BM3RSB-025 22A SC-N1 200V 25.3A
460 BM3RSB-013 11A SC-4-0 200V 17.5A
208 BM3VSB-050 28A SC-N2 200V 32.2A
VFZ801A-7W 230 BM3VSB-050 30A SC-N1 200V 25.3A
460 BM3RSB-020 14A SC-4-1 200V 17.5A
208 BM3VSB-050 28A SC-N2 200V 32.2A
VFC805A-7WS 230 BM3VSB-050 30A SC-N1 200V 25.3A
460 BM3RSB-020 14A SC-4-1 200V 17.5A
208 BM3VSB-063 48A SC-N2 200V 32.2A
VFZ901A-7W 230 BM3VSB-063 52A SC-N2 200V 32.2A
460 BM3RSB-032 26A SC-N1 200V 25.3A
VFZ401A-5W 575 BM3RSB-2P5 1.6A SC-03 200V 7.8A
VFZ501A-5W 575 BM3RSB-004 3.2A SC-03 200V 7.8A
VFZ601A-5W 575 BM3RSB-6P3 5.5A SC-03 200V 7.8A
VFZ501A-5W 575 BM3RSB-013 9A SC-4-0 200V 17.5A
VFZ801A-5W 575 BM3RSB-020 14A SC-4-1 200V 17.5A
VFC805A-5WS 575 BM3RSB-020 14A SC-4-1 200V 17.5A
VFZ901A-5W 575 BM3RSB-025 21A SC-N1 200V 25.3A
*3 Recommended equipment is a reference model manufactured by Fuji Electric.
*4 UL evaluation test was carried out at the protector (MMS).

(Figure 9)Recommended protector connection