Predesign Pile Foundation EGYPT STERLING WILSON Draft v10.1 August 2018
Predesign Pile Foundation EGYPT STERLING WILSON Draft v10.1 August 2018
Predesign Pile Foundation EGYPT STERLING WILSON Draft v10.1 August 2018
Barcelona-Tech
1 Content
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 4
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
1. Executive Summary
This report defines the pile foundations characteristics for Solar Plant in Egypt for Sterling
Wilson Project.
To design a technical advisory of deep foundation for a Solar Plant in Egypt for Sterling
Wilson Project, we have analyzed the next load case determined by our client, PV
Hardware send us on August 2018:
The design of piles is based on “Driven” steel piles. The steel shape is inserted in the
soil directly.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 5
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 6
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Horizontal Ultimate Compression Ultimate Tension Ultimate Soil Ultimate Soil Length (m)
Zone Location Section Material Fshear (N) Soil Resistance (N) Fcomp (N) Soil Resistance (N) Ftension (N) Resistance (N) Mx (Nm) Moment (Nm)
HEA160 S355 11059 22330 14849 165505 92 74959 23915 34388 2.57
Central
I
IPE 160 S355 9397 12307 14411 97363 478 36647 14565 18953 2.65
HEA 140 S355 3272 9191 9765 89933 2336 36489 9966 14154 1.88
Central
II
CP170x70x20x3 S355 2517 4514 10195 55624 2879 20836 3985 6952 1.75
Lateral
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 7
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Taking in account the geotechnical report “Geo technical study”, we define our
geotechnical soil model:
Depth (m) Soil Type Gamma (kN/m3) c (kPa) Fi Compacity UCS (Mpa)
0 6 Medium Sand 16.8 0 37 60
Stage 1 (Driven)
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 8
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
3. Applicable Standards.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 9
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 10
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
L= Pile length
a) When for small increments of effort, great vertical displacements are obtained
b) When the vertical displacements at 100% of the load are greater than (N x L /
(EA)) + 8mm
c) When the vertical displacements at discharge load until 0% are greater than 5
mm
d)
a) When for small increments of effort, great vertical displacements are obtained.
b) When the vertical displacements at 100% of the load are greater than (N x L /
(EA)) + 5 mm
c) When the vertical displacements at discharge load until 0% are greater than 5
mm
a) When for small increments of effort, great vertical displacements are obtained.
b) When the lateral displacements at 100% of the load are greater than 10 mm
c) When the lateral displacements at discharge load until 0% are greater than 5
mm
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 11
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
5. Methodology.
5.1 Ultimate Load Compression Capacity (Qu )
The Ultimate Load Compression Capacity or load-carrying capacity have been
calculated by the equation:
Qu = Q p + Q s
Where:
Qp = load-carrying capacity of the pile bottom point by Meyerhoof method
Qs = frictional resistance (skin friction) Ultimate Load Tension Capacity (Tug ) by
Meyerhoof method
We compute this method by a spreadsheet based on next schema for our soil model:
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 12
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
The Ultimate Lateral Load Capacity have been calculated by Brinch Hansen Method.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 13
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Glossary of terms:
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 14
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 15
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
II LATERAL CP 170
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 16
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Based on Meyerhoff method for tip strength and vertical effective pressure for shaft friction in compression for cohesionless soils
Fcomp(N) Fup(N) L BH
HEA 160
14849 92 2,57
STEEL PROFILE UNCOHESIVE SHAFT FRICTION (N) COHESIVE SHAFT FRICTION (N) WEIGHT W (N) UPLIFT CAPACITY (N) SAFETY FACTOR
UPLIFT Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Ku delta/fi L/D Lcr (m) Tun 1 Tun 2 Tun (N) α' Tun (N)
soil1 0 6 16,8 0 37 60 0 0,16 0,02432 0,906 0,00388 2,57 2,15 0,9575 13,05 2,09 76880,69 74176,45 74176,45 0,00 782,77
2,570 Tun total 74176,45 Tun total 0,00 Wtotal 782,77 Tug 74959,22 814,77 74959,22
STEEL PROFILE UNCOHESIVE SHAFTand TIP (N) COHESIVE SHAFT FRICTION (N) COHESIVE TIP RESITANCE (N) ROCK SHAFT FRICTION (N) ROCK TIP RESISTANCE (N) SAFETY FACTOR
COMPRESSION Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Tun(N) α qp(N) qud(MPa) qs (N) qud (MPa) Nphi qp (N)
soil1 0 6 16,8 0 37 60 0 0,16 0,02432 0,906 0,00388 2,57 165505,00
2,570 Tun total 165505,00 Tun total 0,00 Tun total 0 Tun total 0,00 Tun total 0 11,15 165505,00
Fcomp(N) Fup(N) L BH
IPE 160
14411 478 2,65
STEEL PROFILE SAND SHAFT FRICTION (N) COHESIVE SHAFT FRICTION (N) WEIGHT W (N) UPLIFT CAPACITY (N) SAFETY FACTOR
UPLIFT Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Ku delta/fi L/D Lcr (m) Tun 1 Tun 2 Tun (N) α' Tun (N)
soil1 0 6 16,8 0 37 60 0 0,082 0,01312 0,623 0,00201 2,65 2,15 0,9575 13,05 1,07 56208,58 36229,75 36229,75 418,13
2,650 Tun total 36229,75 Tun total 0,00 Wtotal 418,13 Tug 36647,88 76,67 36647,88
STEEL PROFILE UNCOHESIVE SHAFTand TIP (N) COHESIVE SHAFT FRICTION (N) COHESIVE TIP RESITANCE (N) ROCK SHAFT FRICTION (N) ROCK TIP RESISTANCE (N) SAFETY FACTOR
COMPRESSION Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Tun(N) α qp(N) qud(MPa) qs (N) qud (MPa) Nphi qp (N)
soil1 0 6 16,8 0 37 60 0 0,082 0,01312 0,623 0,00201 2,65 97363,00
2,650 Tun total 97363,00 Tun total 0,00 Tun total 0 Tun total 0,00 Tun total 0 6,76 97363,00
Fcomp(N) Fup(N) L BH
HEA 140
9765 2336 1,88
STEEL PROFILE SAND SHAFT FRICTION (N) COHESIVE SHAFT FRICTION (N) WEIGHT W (N) UPLIFT CAPACITY (N) SAFETY FACTOR
UPLIFT Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Ku delta/fi L/D Lcr (m) Tun 1 Tun 2 Tun (N) α' Tun (N)
soil1 0 6 16,8 0 37 60 0 0,14 0,01862 0,794 0,00314 1,88 2,15 0,9575 13,05 1,83 36054,46 36025,81 36025,81 463,40
1,880 Tun total 36025,81 Tun total 0,00 Wtotal 463,40 Tug 36489,21 15,62 36489,21
STEEL PROFILE UNCOHESIVE SHAFTand TIP (N) COHESIVE SHAFT FRICTION (N) COHESIVE TIP RESITANCE (N) ROCK SHAFT FRICTION (N) ROCK TIP RESISTANCE (N) SAFETY FACTOR
COMPRESSION Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Tun(N) α qp(N) qud(MPa) qs (N) qud (MPa) Nphi qp (N)
soil1 0 6 16,8 0 37 60 0 0,14 0,01862 0,794 0,00314 1,88 89933,00
1,880 Tun total 89933,00 Tun total 0,00 Tun total 0 Tun total 0,00 Tun total 0 9,21
Fcomp(N) Fup(N) L BH
CP170x3
10195 2879 1,75
STEEL PROFILE SAND SHAFT FRICTION (N) COHESIVE SHAFT FRICTION (N) WEIGHT W (N) UPLIFT CAPACITY (N) SAFETY FACTOR
UPLIFT Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Ku delta/fi L/D Lcr (m) Tun 1 Tun 2 Tun (N) α' Tun (N)
soil1 0 6 16,8 0 37 60 0 0,07 0,0119 0,682 0,0009728 1,75 2,15 0,9575 13,05 0,91 26833,87 20702,76 20702,76 133,64
1,750 Tun total 20702,76 Tun total 0,00 Wtotal 133,64 Tug 20836,40 7,24 20836,40
STEEL PROFILE UNCOHESIVE SHAFTand TIP (N) COHESIVE SHAFT FRICTION (N) COHESIVE TIP RESITANCE (N) ROCK SHAFT FRICTION (N) ROCK TIP RESISTANCE (N) SAFETY FACTOR
COMPRESSION Depth Depth Gamma (kN/m3) c (kPa) Fi Comp rel (%) UCS (MPa) Width (m) A tip (m2) Perimeter (m) A steel (m2) L (m) Tun(N) α qp(N) qud(MPa) qs (N) qud (MPa) Nphi qp (N)
soil1 0 6 16,8 0 37 60 0 0,07 0,0119 0,682 0,0009728 1,75 55624,00
1,750 Tun total 55624,00 Tun total 0,00 Tun total 0 Tun total 0,00 Tun total 0 5,46
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 17
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
PILE
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 18
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
PILE
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 19
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
PILE
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 20
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
II Lateral CP 170
PILE
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 21
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 22
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 23
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 24
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 25
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 26
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 27
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
9. Observations:
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 28
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
2. First consideration
Regarding the comments that you send us on 14th August 2018, we can attach the
following justifications, although these documents are internal between our academic
institution, UPC and our PH HARDWARE client, in accordance with our contractual
conditions and as specified in point 9 of our document.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 29
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
PH Hardware has sent for evaluation several alternatives that have been evaluated. In
each of these versions, various types of profiles and load cases have been evaluated,
which in each version have been updated as they have been delivered to us.
Last version sent on August 13, 2018 corresponds to version 9, last up to now.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 30
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
From this academic institution, and after an extensive study on the proposed structural
solution, we have come to the conclusion that there is no universal norm that resolves
the problem in all its variables. That is why we are guided as a design criterion in the
Australian regulation, given that according to the comparative study, it is the one that
gives a more satisfactory solution. We consider the Australian code only to evaluate the
results of field test campaigns.
On the other hand, the norm Egyptian follows the indications of the European norm EC-
7 and EC-8, all based on the mechanics of the soil according to the principles of
mechanics rational, according to the guidelines of the laws of Winkler and Brinch Hansen
Method.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 31
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
On the other hand, the values of the parameters used, are the result of a long experience
of collaboration between our institution and our client PH Hardware, values validated in
numerous tests in various solar parks around the world, forming part of our know-how.
The calculation of the piles is based on the principles of soil mechanics according to the
principles of rational mechanics, according to the guidelines of the laws of Winkler and
Brinch Hansen Method. Our software follows these guidelines.
In geotechnical engineering, bearing capacity is the capacity of soil to support the loads
applied to the ground. The bearing capacity of soil is the maximum average contact
pressure between the foundation and the soil which should not produce shear failure in
the soil. Ultimate bearing capacity (qf) is the theoretical maximum pressure which can
be supported without failure; allowable bearing capacity (qa) is the ultimate bearing
capacity divided by a factor of safety. Sometimes, on soft soil sites, large settlements
may occur under loaded foundations without actual shear failure occurring; in such
cases, the allowable bearing capacity is based on the maximum allowable settlement.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 32
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Brinch Hansen (1970) provided equations to estimate limit bearing capacity for two
separate cases of strength parameters: (1) f> 0, and (2) f= 0 (undrained clay).
In addition, for each of these cases there are two separate subcases:
(b) there is a horizontal component of load in the direction of the length of the footing,
or in both directions (width and length of the footing). Equations to estimate limit bearing
capacity are provided in the following sections for each of these situations.
In all cases, the limit load that can be carried at the bearing level is given by the following
equation
• QbL = qbL · Af
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 33
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 34
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 35
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
10. Methodology.
10.1 Ultimate Load Compression Capacity
The Ultimate Load Compression Capacity or load-carrying capacity have been
calculated by the equation:
Qu = Q p + Q s
Where:
Qp = load-carrying capacity of the pile bottom point by Meyerhoof method
Qs = frictional resistance (skin friction) Ultimate Load Tension Capacity (Tug ) by
Meyerhoof method
We compute this method by a spreadsheet based on next schema for our soil model:
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 36
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
The Ultimate Lateral Load Capacity have been calculated by Brinch Hansen Method.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 37
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
In relation to the method of calculation of the values of the lengths of the piles to
evaluate the friction between the metal profile and the terrain for compressive loads, we
enclose the theoretical formulation used, with the values that appear in our spreadsheet.
For cohesionless soils and considering the geotechnical parameters for soil:
Shaft Resistance:
- According with the specific weight of soil and the length of pile, we define the vertical
pressure “σ” (kN/m2) at the top and base of pile “z”:
𝜎 =𝛾·𝑧
- With this vertical pressure we found the unit shaft resistance “τ” (kN/m2) at top and
base of pile, according with the angle of friction of soil “θ” and type of pile:
𝜏 = 𝜎 · 𝑘𝑓 · 𝑓 · tan(𝜃)
- Finally the total shaft resistance “Rshaft” will be the unit shaft resistance affected by the
perimeter “P” and length of pile “L”:
𝑅𝑠ℎ𝑎𝑓𝑡 = 𝜏 · 𝑃 · 𝐿
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 38
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
Tip Resistance:
𝑅𝑡𝑖𝑝 = 𝜎 · 𝑓𝑝 · 𝑁𝑞 · 𝐴𝑝
The reference standard EC-7 only mentions design of pile for uplift loads in points 7.6.3.1
sections 5 and 6, but does not indicate the calculation method.
According to the mechanics of soil, according to the technical bibliography, the method
of Das Seely is the most indicated to evaluate the capacity of cohesionless soils for uplift
loads. Braja M.Das for example.
This method consider the geotechnical parameters of soil to evaluate the traction
capacity of soil:
1) Vertical pressure at base level of pile “σ”. It depends of specific weight “γ”.
4) Compactness of soil.
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 39
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
According to the mechanics of soil, according to the technical bibliography, the method
of Broms is the most indicated to evaluate lateral capacity of soil. See Braja M.Das for
example. The process of this method is included in our documents in detail.
12. Observations:
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 40
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 41
Predesign pile foundation for a Solar Farm in Egypt STERLING WILSON Project
UPC- ETSEIAT
Despatx 211, TR45
C/Colom nº 11,
Terrassa, 08222 (Barcelona) Spain
www.upc.edu 42