AB STRATIX SWITCH-5700 Guide
AB STRATIX SWITCH-5700 Guide
Topic Page
Summary of Changes 2
Additional Resources 2
Stratix 2000 Ethernet Unmanaged Switches—Series B 3
Stratix 2000 Ethernet Unmanaged Switches—Series A 10
Stratix 2500 Ethernet Lightly Managed Switches 17
Stratix 5400 Ethernet Managed Switches 21
Stratix 5410 Ethernet Managed Switches 26
Stratix 5700 Ethernet Managed Switches 32
ArmorStratix 5700 Ethernet Managed Switches 42
Stratix 5800 Ethernet Managed Switches and Expansion Modules 47
Stratix 6000 Ethernet Managed Switches 55
Stratix 8000 and 8300 Ethernet Managed Switches 59
Stratix 5100 Wireless Access Point/Workgroup Bridge 67
Stratix 5900 Services Router 69
Stratix 5950 Security Appliance 72
Embedded Switch Technology 75
Configurable NAT Router 79
Accessories 82
Summary of Changes
This publication contains new and updated information as indicated in the following table.
Topic Page
Specifications for Stratix 5800 catalog numbers 1783-MMS10BE/B, 1783-MMS10E/B, 1783-MMS10ER/B, 1783-MMS10/B, 47…52
1783-MMS10R/B 1783-MMS10B/B 1783-MMS10EA/B, 1783-MMS10EAR/B, 1783-MMX8EA/A, 1783-MMX8SA/A
Ethernet tap catalog numbers 1783-ETAPK, 1783-ETAP1FK, 1783-ETAP2FK 75
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
Configurable NAT Router User Manual, publication 1783-UM008 Describes how to install, configure, and troubleshoot the NAT router.
EtherNet/IP Industrial Protocol White Paper, publication ENET-WP001 Describes how to implement services and data objects on a TCP/UDP/IP based
Ethernet network.
Stratix Managed Switches User Manual, publication 1783-UM007 Describes how to configure and troubleshoot Stratix 5400, 5410, 5700, 8000, 8300,
and ArmorStratix 5700 switches.
Stratix 2000 Ethernet Unmanaged Switches User Manual, publication 1783-UM011 Describes how to use DIP switches and status indicators on Stratix 2000 switches.
Stratix 2500 Lightly Managed Switches User Manual, publication 1783-UM009 Describes how to configure and troubleshoot Stratix 2500 switches.
Stratix 5800 Ethernet Managed Switches User Manual, publication 1783-UM012 Describes how to configure and troubleshoot Stratix 5800 switches.
Stratix 6000 Ethernet Managed Switches User Manual, publication 1783-UM001 Describes how to configure and troubleshoot Stratix 6000 switches.
Stratix 5100 Wireless Access Point/Workgroup Bridge User Manual, publication 1783-UM006 Describes how to install, configure, and troubleshoot the wireless access point.
Stratix 5900 Services Router User Manual, publication 1783-UM005 Describes how to install, configure, and troubleshoot the router.
Stratix 5950 Security Appliance User Manual, publication 1783-UM010 Describes how to install, configure, and troubleshoot the security appliance.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, http://www.rockwellautomation.com/global/certification/ Provides declarations of conformity, certificates, and other certification details.
overview.page
76.8 mm
(3.02 in.)
29.6 mm 29.6 mm
68 mm
(1.17 in.) (1.17 in.)
2.68 in.)
2000
R
33.5 mm 25.0 mm
5
(1.31 in.) (0.98 in.)
6 mm
(0.24 in.)
4
3 48.3 mm 35 mm
114.5 mm (1.9 in.) (1.38 in.) 20.0 mm
2 (4.51 in.) (0.79 in.)
1 43.25 mm
(1.70 in.)
OFF
ON
SW1
SW2
32664-M
2000
R
33.5 mm
(1.32 in.) 6 mm
6 8
(0.24 in.) 35 mm
(1.38 in.)
4 6
48.3 mm
3 4
114.5mm (1.9 in.) 35 mm 20 mm
(4.50 in.) (1.38 in.) (0.79 in.)
1 2 43 mm
(1.7 in.)
OFF
ON
SW1
SW2
32663-M
2000
R
7 8
6 mm 52.0 mm
(0.24 in.) (2.05 in.)
5 6
134 mm
3 4
(5.28 in.) 48.3 mm
35 mm
(1.90 in.) 20.0 mm
(1.38 in.)
G1 G2 (0.79 in.)
53.5 mm
1 2 (2.11 in.)
OFF
ON
SW1
SW2
32662-M
114.8 mm
(4.52 in.)
79.6 mm 106 mm 79.6 mm
(3.13 in.) (4.17 in.) (3.13 in.)
2000
42.5 mm
9 10 17 18
(1.67 in.) 6 mm 70 mm
(0.24 in.) (2.76 in.)
7 8 15 15
5 6 13 14 134 mm
(5.27 in.) 48.3 mm 35 mm 20 mm
3 4 11 12
(1.90 in.) (1.38 in.) (0.79 in.)
1 2 53.5 mm
(2.11 in.)
OFF
ON
SW1
SW2
32661-M
The following table lists Stratix 2000 series A switches and their series B replacements. For specifications of series B
switches, see page 3.
Table 5 - Stratix 2000 Series Change
Series A Cat. No. Series B Replacement Cat. No. Change(1)
1783-US4T1F/A 1783-US4T1F/B Same catalog number and configuration
1783-US4T1H/A 1783-US4T1H/B Same catalog number and configuration
1783-US5T/A 1783-US5T/B Same catalog number and configuration
1783-US5TG/A 1783-US5TG/B Same catalog number and configuration
1783-US6T2F/A 1783-US6T2F/B Same catalog number and configuration
1783-US6T2H/A 1783-US6T2H/B Same catalog number and configuration
1783-US7T1F/A 1783-US7T1F/B Same catalog number and configuration
1783-US7T1H/A 1783-US7T1H/B Same catalog number and configuration
1783-US8T/A 1783-US8T/B Same catalog number and configuration
1783-US16T/A 1783-US16T/B Same catalog number and configuration
1783-US14T2S/A 1783-US16T2S/B New catalog number
Replaced 2 GE combo ports with 2 GE copper ports on series B replacement
Added 2 GE SFP slots to series B replacement
1783-US6TG2CG/A 1783-US8TG2GX/B New catalog number
Added 2 FE copper ports to series B replacement
(1) FE = Fast Ethernet; GE = Gigabit Ethernet.
6 mm
(0.24 in.)
115 mm
35 mm
(4.53 in.)
(1.38 in.)
6 mm
(0.24 in.)
35 mm
115 mm
(1.38 in.)
(4.53 in.)
6 mm
(0.24 in.)
135 mm 35 mm
(5.31 in.) (1.38 in.)
6 mm
(0.24 in.)
7 8 35 mm
(1.38 in.)
135 mm
5 6
(5.31 in.)
3 4
1783-US8T
1 2
32312-M
6 mm
(0.24 in.)
135 mm
(5.31 in.) 35 mm
(1.38 in.)
38.1 mm
(1.79 in.)
32643-M
45.7 mm
(1.79 in.)
32642-M
CIP Sync
Cat. No. Total Ports RJ45 Ports(1) Combo Ports PoE/PoE+ Ports SFP Slots Firmware Type NAT DLR
(IEEE 1588)
1783-HMS4C4CGN 8 — 4 FE + 4 GE — — Layer 2 Yes Yes Yes
1783-HMS8T4CGN 12 8 FE 4 GE — — Layer 2 Yes Yes Yes
1783-HMS8S4CGN 12 — 4 GE — 8 FE Layer 2 Yes Yes Yes
1783-HMS4T4E4CGN 12 4 FE 4 GE 4 FE — Layer 2 Yes Yes Yes
1783-HMS4S8E4CGN 16 — 4 GE 8 FE 4 FE Layer 2 Yes Yes Yes
1783-HMS16T4CGN 20 16 FE 4 GE — — Layer 2 Yes Yes Yes
1783-HMS8TG4CGN 12 8 GE 4 GE — — Layer 2 Yes Yes Yes
1783-HMS8SG4CGN 12 — 4 GE — 8 GE Layer 2 Yes Yes Yes
1783-HMS4EG8CGN 12 — 8 GE 4 GE — Layer 2 Yes Yes Yes
1783-HMS4SG8EG4CGN 16 — 4 GE 8 GE 4 GE Layer 2 Yes Yes Yes
1783-HMS16TG4CGN 20 16 GE 4 GE — — Layer 2 Yes Yes Yes
1783-HMS8TG8EG4CGN 20 8 GE 4 GE 8 GE — Layer 2 Yes Yes Yes
1783-HMS8TG4CGR 12 8 GE 4 GE — — Layer 3 Yes Yes Yes
1783-HMS8SG4CGR 12 — 4 GE — 8 GE Layer 3 Yes Yes Yes
1783-HMS4EG8CGR 12 — 8 GE 4 GE — Layer 3 Yes Yes Yes
1783-HMS4SG8EG4CGR 16 — 4 GE 8 GE 4 GE Layer 3 Yes Yes Yes
1783-HMS16TG4CGR 20 16 GE 4 GE — — Layer 3 Yes Yes Yes
1783-HMS8TG8EG4CGR 20 8 GE 4 GE 8 GE — Layer 3 Yes Yes Yes
(1) FE = Fast Ethernet; GE = Gigabit Ethernet
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5400 switches. Actual faceplates vary depending on the catalog number.
1.75 cm
(0.69 in.)
15.54 cm 12.92 cm
(6.12 in.) (5.09 in.)
R
15.54 cm 16.45 cm
(6.12 in.)
(6.48 in.)
13.03 cm
(5.13 in.)
1.24 cm
(0.49 in.)
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 44.45 mm (1.75 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5410 switches. Actual faceplates vary depending on the catalog number.
44.5 cm
(17.75 in.)
1 2 3 4 5 6 7 8 9 10 11 12 25 26 1 4 5 10/100/1000 PoE+ 8 9 12
IN IN
4.45 cm 13 14 15 16 17 18 19 20 21 22 23 24 27 28
Disp.
Mode OUT OUT
TOD
EIP Mod
EIP Net
Setup
GPS
TimeCD
1
2
Out
2
Speed
Duplex
PRP
DLR
PoE
(1.75 in.)
1
3
4
35.6 cm
(14.0 in.)
32564-M
46.53 cm
(18.32 in.)
1 2 3 4 5 6 7 8 9 10 11 12 25 26 1 4 5 10/100/1000 PoE+ 8 9 12
IN IN
3.18 cm 13 14 15 16 17 18 19 20 21 22 23 24 27 28
Disp.
Mode OUT OUT
TOD
EIP Mod
EIP Net
Setup
GPS
TimeCD
1
2
Out
2
Speed
Duplex
PRP
DLR
PoE
(1.25 in.)
1
3
4
.61 cm 32565-M
(.24 in.)
3.28 cm
(1.29 in.)
0.56 cm
(0.22 in.)
3.63 cm
3.63 cm
(1.43 in.) (1.43 in.)
53.8 cm
(21.18 in.)
46.53 cm
(18.32 in.)
17.66 cm 16.59 cm
(6.95 in.) (6.53 in.)
32564-M
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5700 switches. Actual faceplates vary depending on the catalog number.
6 SFP-port Switches 6-port Switches
1783-BMS4S2SGL, 1783-BMS4S2SGA 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA,
1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA
8.00 cm 7.48 cm
(3.15 in.) (2.94 in.)
R
Express
Setup
Pwr A
Console
DC+
DC-
Com
IN2
Ref
IN1
12.19 cm
(4.8 in.) 11.67 cm
0.75 cm
11.45 cm (4.59 in.)
(0.29 in.) 0.75 cm
(4.51 in.) 10.92 cm
(0.29 in.)
(4.3 in.)
9.14 cm 9.14 cm
(3.6 in.) (3.6 in.)
R R
12.95 cm 12.95 cm
(5.1 in.) (5.1 in.)
11.67 cm 13.58 cm
(4.59 in.) (5.345 in.)
10.92 cm 0.75 cm 0.75 cm
(0.29 in.) 12.83 cm (0.29 in.)
(4.3 in.) (5.05 in.)
12.95 cm
(5.1 in.)
13.58 cm
(5.345 in.)
0.75 cm
12.83 cm
(0.29 in.)
(5.05 in.)
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the ArmorStratix 5700 switches. Actual faceplates vary depending on the catalog
number.
8-port and 10-port Switches 16-port and 18-port Switches
1783-ZMS8TA, 1783-ZMS4T4E2TGP, 1783-ZMS4T4E2TGN 1783-ZMS16TA, 1783-ZMS8T8E2TGP, 1783-ZMS8T8E2TGN
23.75 cm 30.09 cm
(9.35 in.) (11.85in.)
5.78 cm 5.78 cm
(2.2 in.) (2.2 in.)
24.38 cm 24.38 cm 2
14.47 cm 14.47 cm 4
(9.6 in.) (9.6 in.)
(5.6 in.) (5.6 in.)
3.93 cm
3.93 cm
(1.5 in.)
(1.5 in.) 32493
32492
21.58 cm 27.98 cm
(8.4 in.) (11.0 in.)
24-port Switch
1783-ZMS24TA
37.46 cm
(14.75in.)
5.78 cm
(2.2 in.)
24.38 cm
(9.6 in.)
14.47 cm
(5.6 in.)
3.93 cm
(1.5 in.)
32494
35.38 cm
(13.9 in.)
24.84 cm 24.84 cm
(9.77 in.) (9.77 in.)
32496
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5800 switches. Actual faceplates vary depending on the catalog number.
Base Switches without Advanced Feature Support Base Switches with Advanced Feature Support
1783-MMS10B, 1783-MMS10BE, 1783-MMS10, 1783-MMS10EA, 1783-MMS10EAR
1783-MMS10E, 1783-MMS10R, 1783-MMS10ER
11.17cm
9.14 cm (4.40 in.)
(3.60 in.)
5800
5800
Console
4
Console
PoE
Console
1 2 6
1 15.24 cm
PoE
Pwr 15.24 cm (6.0 in.)
2
Setup
EIP EIP
(6.0 in.) Alarm
IN 1 IN 2 OUT
7 Mod Net
Express
Setup
IN 1 IN 2 OUT
Alarm
8
PoE
10
0.83 cm
1783-MMS10E
(0.33 in.)
0.83 cm 33805-M
(0.33 in.)
32798-M
8-port Expansion Modules 16-port Expansion Modules All Switches and Expansion Modules
1783-MMX8T, 1783-MMX8E, 1783-MMX16T, 1783-MMX16E, 1783-MMX14T2S
1783-MMX8EA, 1783-MMX8S,
1783-MMX8SA, 1783-MMX6T2S 13.46 cm
7.72 cm (5.30 in.)
6.60 cm (3.40 in.)
(2.60 in.)
6.60 cm
4.06cm (2.60 in.)
(1.60 in.)
5800
5800
9
1
10
2
PoE
3 11
4 12
15.24 cm 15.24 cm
(6.0 in.) 13
(6.0 in.)
5
14
6
PoE
15
15.16 cm
32797-M
8 (5.97 in.)
16
1783-MMX8E
1783-MMX14T2S
32800-M
32799-M
Base Switches without Advanced Feature Support Base Switches without Advanced Feature Support
Mated with Any 8-port Expansion Module Mated with Any 16-port Expansion Module
1783-MMS10B, 1783-MMS10BE, 1783-MMS10, 1783-MMS10B, 1783-MMS10BE, 1783-MMS10,
1783-MMS10E, 1783-MMS10R, 1783-MMS10ER 1783-MMS10E, 1783-MMS10R, 1783-MMS10ER
14.22 cm
16.76 cm
(5.60 in.)
(6.60 in.)
Base Switches with Advanced Feature Support Base Switches with Advanced Feature Support
Mated with Any 8-port Expansion Module Mated with Any 16-port Expansion Module
1783-MMS10EA, 1783-MMS10EAR 1783-MMS10EA, 1783-MMS10EAR
16.25 cm 18.79 cm
(6.40 in.) (7.40 in.)
5800 5800
Console
Console
Console
Console
1 1
2
2
IN 1 IN 2 OUT
IN 1 IN 2 OUT Alarm
Alarm
33807-M
33806-M
Mount the switches, as shown, in the vertical position only. We do not recommend horizontal mounting due to thermal
considerations. Follow these guidelines:
• Provide 50 mm (2 in.) of space on all sides for adequate heat dissipation.
• Leave 100 mm (4 in.) for installation and removal if using the fiber-optic port on the bottom of the
1783-EMS08T switch.
52.07 mm
(2.05 in.)
12 cm 1
(0.47 in.) 2
88.9 mm
12 mm 27.7 mm SFP Module Installed
(3.50 in.)
(0.47 in.) (1.09 in.)
Table 39 - Technical Specifications - Stratix 8000 and 8300 Fiber Expansion Module
Attribute 1783-MX08F
Ethernet data rate 100 Mbps
Connecting mode Full-duplex
Optical wavelength 1310 nm
Optical cable length, max Graded index multimode fiber; 2000 m
Optical link budget 8 dB with 62.5/125 μm multimode cable
4 dB with 50/125 μm multimode cable
Connector type IEC 61754-20 LC connector
Table 40 - Technical Specifications - Stratix 8000 and 8300 PoE Expansion Modules
Attribute 1783-MX04E 1783-MX04T04E
Description Expansion module Expansion module
4 ports, PoE • 4 ports, copper
• 4 ports, PoE
Backplane power 3.3V DC, 0.94 A max 3.34V DC, 1.08 A max
PoE input power 48V DC for PoE 48V DC for PoE
54V DC for PoE+ for a combination of PoE and PoE+ 54V DC for PoE+ for a combination of PoE and PoE+
2.5 A max 2.4 A max
Power consumption(1) 3 W @ 24V DC @ 40˚C (104˚F), 7.3 W max 3.5 W @ 24V DC @ 40˚C (104˚F), 7.9 W max
PoE power at 44V: 62 W max PoE power at 44V: 62 W max
Power dissipation 7.3 W 7.9 W
Isolation voltage 60V (continuous), basic insulation type, expansion backplane to network ports, expansion backplane to power ports, and power ports to
network ports
No isolation between individual network ports
Type tested at 1570V DC for 60 s
Wire size, Ethernet connection(2) RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to
ISO/IEC 24702
Wiring category(3) 2 - on Ethernet ports
2 - on power ports
Enclosure type rating None (open-style)
North American temp code T4
IEC temp code T4
SFP modules —
(1) For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used.
(2) See page 84 for recommended products.
(3) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 41 - Environmental Specifications - Stratix 8000 and 8300 Expansion Modules (continued)
1783-MX04S,
Attribute 1783-MX08T 1783-MX08F 1783-MX04E, 1783-MX04T04E
1783-MX08S
Shock, nonoperating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions Group 1, Class A
CISPR11 (IEC 61000-6-4)
ESD immunity 8 kV contact discharges 6 kV contact discharges
IEC 61000-4-2 15 kV air discharges 8 kV air discharges
Radiated RF immunity 20V/m with 1 kHz sine-wave 80% AM from 10V/m with 1 kHz sine-wave 80% AM from
IEC 61000-4-3 80…1000 MHz 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
10V/m with 1 kHz sine-wave 80% AM from 3V/m with 1 kHz sine-wave 80% AM from
1000…2700 MHz 2000…2700 MHz
EFT/B immunity ±4 kV at 2.5 kHz and ±2 kV at 5 kHz — ±2 kV at 5 kHz on power ports and
IEC 61000-4-4 on Ethernet ports ±2 kV at 5 kHz on Ethernet ports
Magnetic field immunity 30 A/m long duration and 300 A/m short duration at 30 A/m long duration and 300 A/m short duration at
IEC 61000-4-8 50 Hz and 60 Hz 50 Hz
This illustration shows dimensions for the 1783-MS10T switch and the 1783-MX08T expansion module. Dimensions
for the other switches are the same as the 1783-MS10T switch. Dimensions for the other expansion modules are the
same as the 1783-MX08T expansion module.
Airflow around the switch and through the vents is unrestricted. To prevent the switch from overheating, these
minimum clearances must be met:
• Top and bottom: 105 mm (4.13 in.)
• Left and right: 90 mm (3.54 in.)
• Front: 65 mm (2.56 in.)
14.8 cm
(5.83 in.)
9.81 cm
33.27 cm (3.87 in.)
11.1 cm
(13.1 in.)
(4.38 in.)
Switch
(side view)
11.75 cm
Switch and Expansion Modules (mated) (4.63 in.)
31801-M
For panel-mounting, the height of the center of the mounting holes on both the top and bottom latches measures 8.73 mm (0.34 in.) above the
top surface (or below the bottom surface) of the switch.
On the switch base unit, the tab hole center-to-center spacing is 6.83 cm (2.69 in.).
For expansion modules, the tab hole center-to-center spacing is 4.36 cm (1.72 in.).
1783-WAPZK9 For use in Australia, New Zealand and all other Countries that recognize the Radiocommunications
Regulatory Domain Z (Short Range Devices) Standard.
E134
1783-WAPCK9 CMIIT ID: 2014AJ2894 For use in China and all other Countries that recognize The Bureau of Radio Administration of MIIT
Regulatory Domain C (Fixed Radio Devices).
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
196 mm
(7.7 in.)
129.54 mm
(5.10 in.)
159.26 mm
(6.27 in.)
32593-M
This illustration shows dimensions for the 1783-ETAP tap. The dimensions for the other catalog numbers are the same.
122.68 mm
(4.83 in.) 131.57 mm
(5.18 in.)
104.9 mm
(4.13 in.)
35.05 mm
(1.38 in.)
When mounting the 1783-NATR device, allow a minimum clearance between the device and adjacent equipment of
2.54 cm (1 in.) on all sides.
122.68 mm
(4.83 in.) 131.57 mm
(5.18 in.)
104.9 mm
(4.13 in.)
35.05 mm
(1.38 in.)
Accessories
Small Form-factor Pluggable (SFP) Modules
Table 59 - SFP Modules Technical Specifications
Core Size/ Modal
Interface Wavelength
Cat. No. Description Cladding Size Bandwidth Cable Length DOM(5) Transmit Power (dBm) Receive Power (dBm)
Connector (nm) (micron) (MHz/km)
100BASE-LX 10 km
1783-SFP100LX Dual LC 1310 G.652 — Yes -8 (max)…-15 (min) -8 (max)…-28 (min)
singlemode fiber (32,808 ft)
100BASE-EX 40 km
1783-SFP100EXC Dual LC 1310 G.652(4) — No 0 (max)…-5 (min) -8 (max)…-28 (min)
singlemode fiber (131,234 ft)
100BASE-ZX 80 km
1783-SFP100ZXC Dual LC 1550 G.652(4) — No +2 (max)…-3 (min) -8 (max)…-30 (min)
singlemode fiber (262,467 ft)
1783-SFP100T(1) 100 m
100BASE-T copper RJ-45 — — — No — —
(328 ft)
220 m
62.5/125 160 (722 ft)
275 m
62.5/125 200
1000BASE-SX (902 ft)
1783-SFP1GSX Dual LC 850 Yes -3 (max)…-9.5 (min) 0 (max)…-17 (min)
multimode fiber 500 m
50/125 400 (1640 ft)
550 m
50/125 500 (1804 ft)
1000BASE-LX/LH 10 km
1783-SFP1GLX Dual LC 1310 G.652 — Yes -3 (max)…-9.5 (min) -3 (max)…-20 (min)
singlemode fiber (32,808 ft)
1000BASE-EX 40 km
1783-SFP1GEXE(2) singlemode fiber Dual LC 1310 G.652(4) — (131,234 ft) Yes +3 (max)… -1 (min) +1 (max)…-22 (min)
1000BASE-ZX 70 km
1783-SFP1GZX(3) Dual LC 1550 G.652(4) — Yes +5 (max)…0 (min) -3 (max)…-23 (min)
singlemode fiber (229,659 ft)
1000BASE-T 100 m
1783-SFP1GTE RJ-45 — — — No — —
copper (328 ft)
62.5/125 160 (FDDI) 26 m (85 ft)
33 m
62.5/125 200 (OM1) (108 ft)
66 m
50/125 400 (216 ft)
10GBASE-SR
1783-SFP10GSRE Dual LC 850 82 m Yes -1.2 (max)…-7.3 (min) -1.0 (max)…-9.9 (min)
multimode fiber 50/125 500 (OM2) (269 ft)
300 m
50/125 2000 (984 ft)
400 m
50/125 4700 (1312 ft)
10GBASE-LR 10 km
1783-SFP10GLRE Dual LC 1310 G.652(4) — Yes +0.5 (max)…-8.2 (min) +0.5 (max)…-14.4 (min)
singlemode fiber (32,808 ft)
(1) The 1783-SFP100T module requires Stratix 5400 or 5410 firmware revision 3.001or later, Stratix 5700 firmware revision 8.001or later, or Stratix 8000 firmware revision 12.001 or later.
(2) The 1783-SFP1GEXE module operates on standard single-mode fiber-optic link spans of up to 40 km in length. For back-to-back connectivity, insert a 5-dB inline optical attenuator between the fiber-
optic cable and the receiving port on the SFP module at each end of the link.
(3) When shorter distances of single-mode fiber (SMF) are used, you can avoid overloading the receiver by inserting an inline optical attenuator in the link. If the fiber-optic cable span loss is less than 8
dB, insert a10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the SFP module at each end of the link.
(4) ITU-T G.652 SMF as specified by the IEEE 802.3z standard.
(5) Digital Optical Monitoring (DOM) iis supported on the switches via the command-line interface (CLI).
Memory Cards
Cat. No. Description Compatibility
1784-SD1 1 GB industrial SD card Stratix 5700
Stratix 5950
1784-SDHC8 8 GB industrial SDHC card Stratix 5800
1783-MCF CompactFlash card (spare) Stratix 8000
1783-RMCF CompactFlash card (spare) Stratix 8300
Ethernet Cables
Notes:
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, ArmorStratix, LISTEN.THINK.SOLVE, On-Machine, Rockwell Automation, Rockwell Software, and Stratix are trademarks of Rockwell Automation, Inc.
CIP, CIP Sync, and EtherNet/IP are trademarks of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400