MCC Standard Drawings Rev190723

Download as pdf or txt
Download as pdf or txt
You are on page 1of 47

MAITLAND CITY COUNCIL

STANDARD DRAWINGS

THIS DOCUMENT
To be read in conjunction with: · Any copy of these documents is
· Maitland City Council's 'Manual of uncontrolled. Check the revision date of
Engineering Standards' each sheet against the document held on
· Relevant Australian Standards
· Austroads guidelines
Maitland City Council's website for currency
· Roads & Maritime Services supplements · Copyright in this document belongs to
Maitland City Council.

maitland city council Rev: 23/07/2019


infrastructure & works
po box 220, maitland nsw 2320
SD000
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 02
SD001 FOOTPATH ALLOCATIONS FOR SERVICES & ACCESS SD032 PAVEMENT WIDENING TO NEW KERB & GUTTER
SD002 FOOTWAY PROFILE - NEW SUBDIVISIONS SD034 SILT TRAP & SWALE FOR UNSEALED HARDSTANDS
SD003 TYPICAL CROSS SECTION - RURAL RESIDENTIAL ROADS - NEW SUBDIVISIONS SD035 SUB-SOIL DRAINAGE
SD004 STANDARD KERB PROFILES SD036 KERB STORMWATER OUTLETS & KERB ADAPTOR
SD007 FOOTWAY DRIVEWAY CROSSING - GENERAL ARRANGEMENT SD037 FOOTWAY FLOWPATH
SD008 DRIVEWAY PROFILES - RECOMMENDED MAXIMUM GRADES SD038 FLOOD WARNING SIGNAGE
SD009 DRIVEWAY LOCATIONS - OBSTACLES & OFFSETS SD039/1 GRATED GULLY PITS WITH EXTENDED KERB INLETS
SD010 DRIVEWAYS & KERB LAYBACKS - CONSTRUCTION DETAILS SD039/2 GRATED GULLY PITS WITH EXTENDED KERB INLETS
SD012 DRIVEWAY, FOOTPATH & CYCLEWAY CONSTRUCTION DETAILS SD040 SURFACE INLET PIT
SD013 RURAL DRIVEWAYS - PIPED CROSSING SD043 INTER ALLOTMENT DRAINAGE PIT
SD014-15 KERB CROSSINGS SD045 HEADWALL SCOUR PROTECTION - TYPICAL TREATMENT
SD019/1 FOOTPATH & KERB RAMP LOCATIONS AT INTERSECTION SD046 DRAINAGE SWALE
SD019/2 KERB RAMPS SD047 BIORETENTION SYSTEM (PLANTING BED)
SD020 SHARED FOOTPATH / CYCLEWAY SIGNAGE SD048 WETLAND SPECIES LIST
SD023 BUS STOP FACILITIES - RURAL & URBAN SITES WITH & WITHOUT SHELTERS SD049 STREET TREE PLANTING - TYPICAL TREATMENT
SD025/1 CONCRETE ACCESSES & THRESHOLDS SD050 CONSTRUCTED WETLAND (WITH DETENTION)
SD025/2 CONCRETE ACCESSES & THRESHOLDS - JOINTS & LAYOUTS SD052/1 ON-SITE STORMWATER DETENTION PIT
SD025/3 CONCRETE ACCESSES & THRESHOLDS - JOINT DETAILS SD052/2 ON-SITE STORMWATER DETENTION TANK & DISPOSAL TRENCH
SD025/4 CONCRETE ACCESSES & THRESHOLDS - JOINT DETAILS SD052/3 ON-SITE STORMWATER DISPOSAL TRENCH
SD026 CONCRETE DISH CROSSINGS AT INTERSECTIONS SD057 FENCING
SD027 CUL-DE-SAC OPTIONS SD058/1 STANDARD ACCESS GATE - GENERAL ARRANGEMENT
SD029 STREET NAME SIGN POSTING SF058/2 STANDARD ACCESS GATE - COMPONENTS
SD031 MINIMUM INTERSECTION TREATMENT FOR HIGH/HEAVY TRAFFIC
GENERATING DEVELOPMENTS

maitland city council MAITLAND CITY COUNCIL - STANDARD DRAWINGS Rev: 23/07/2019
infrastructure & works
po box 220, maitland nsw 2320
INDEX OF DRAWINGS SD000
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 02 of 02
5500
1700
1200

300 900 2500 1000 450

BOUNDARY
TOP SOIL SHARED SERVICE CONCRETE SHARED PATH WATER SUB-SOIL
150mm THICK TRENCH (SD12) DRAINAGE
(TYPICAL) (SD035)
& KERB

750 Min.
STREET
5.5m FOOTWAY LIGHTING &
TREE PLANTING

WATERMAIN
4500

1700 (Note 3)

1200

300 900 1500 1000 450


BOUNDARY

TOP SOIL SHARED SERVICE CONCRETE FOOTPATH WATER SUB-SOIL


150mm THICK TRENCH (SD10/12) DRAINAGE
(TYPICAL) (SD035)
& KERB

750 Min.
STREET NOTE:
LIGHTING & 1. ALL DIMENSIONS ARE IN MILLIMETRES.
4.5m FOOTWAY TREE PLANTING 2. SERVICE ENCROACHMENTS & VARIATIONS TO THIS
LAYOUT SHALL BE REPORTED TO COUNCIL & THE
RELEVANT SERVICE AUTHORITY.
WATERMAIN 3. FOOTWAY BETWEEN KERB & FOOTPATH TO BE FULLY
TURFED

maitland city council


infrastructure & works
FOOTPATH ALLOCATIONS FOR Rev: 08/04/2019

po box 220, maitland nsw 2320


SERVICES & ACCESS SD001
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
BOUNDARY
See Note 1 See Note 1 See Note 1
BOUNDARY

FOOTWAY CROSSFALL 4.0% - 25:1

KERB LINE
FOOTWAY CROSSFALL 4.0% - 25:1 2.0m

KERB LINE
1.0m 1.0m 1.0m 1.0m N.S.
HINGE POINT FOR
3:1
BATTER ROUNDING
5:1
+2.5% - 40:1 (Max) +2.5% - 40:1 (Max)

5:1
HINGE POINT FOR
BATTER ROUNDING
1.5m Min. 0.5m 1.2m 1.2m 0.5m 1.5m Min.

FOOTWAY ON FILL FOOTWAY IN CUT


NOTE:
1. FOR CARRIAGEWAY, FOOTWAY & FOOTPATH WIDTHS SEE ROAD DESIGN SECTION OF "MANUAL OF
ENGINEERING STANDARDS"
2. TYPICAL CROSSFALL ON CARRIAGEWAY TO BE -3% FROM CENTRELINE
3. TYPICAL CROSSFALL ON FOOTWAY TO BE +4.0% (25:1) FROM TOP OF KERB TO BOUNDARY
4. FOR PUBLIC UTILITY ALLOCATIONS IN FOOTWAYS SEE SD001
5. FOOTPATH WARRANT - SEE ROAD DESIGN SECTION OF "MANUAL OF ENGINEERING STANDARDS"
MINIMUM FOOTPATH WIDTH 1.5m, CROSSFALL TO BE +2.5% MAXIMUM WITH DESIGN TO SD012 & SD019
6. TREES TO COUNCIL'S "STREET TREE SELECTION GUIDE" OR AS APPROVED - PLANTING IN ACCORDANCE
WITH SD049

maitland city council FOOTWAY PROFILE Rev: 08/04/2019

infrastructure & works


NEW SUBDIVISIONS SD002
po box 220, maitland nsw 2320
MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
email: [email protected]
TWO COAT SEAL WEARING SURFACE (Min. Requirement)
BASE
SUB BASE
SELECT SUBGRADE (WHERE PROVIDED)
0.3m 1.5m 4.00m CL 4.00m

TOP SOIL
N.S. -3.0% -3.0%
FP FP
4:1 4:1
4:1

SUBSOIL DRAINAGE
TYPICAL RURAL CROSS SECTION REFER TO SD035

NOTE:
1. EROSION & SEDIMENTATION CONTROL MEASURES ARE TO BE IMPLEMENTED ON TABLE DRAINS, BATTER SLOPES &
ANY AREAS DISTURBED DURING CONSTRUCTION IN ACCORDANCE WITH THE "BLUE BOOK" & COUNCIL'S "MANUAL OF
ENGINEERING STANDARDS". APPROPRIATE MEASURES SHALL BE IMPLEMENTED FOR BOTH CONSTRUCTION & POST
CONSTRUCTION PERIODS.
TYPICALLY, TABLE DRAINS ARE TO BE PROTECTED WITH TURF, SEED IMPREGNATED JUTE MESH OR OTHER MEASURES
APPROVED BY COUNCIL. ALL DISTURBED AREAS ARE TO BE TOPSOIL & SEEDED.
2. DRIVEWAYS SHALL CONFORM TO SD013.
3. FOR ALTERNATIVE WEARING SURFACE TREATMENTS REFER TO COUNCIL'S "MANUAL OF ENGINEERING STANDARDS".
4. FOR SUBSOIL DRAINAGE REFER TO ARRB "UNSEALED ROAD MANUAL".

maitland city council TYPICAL CROSS SECTION Rev: 01/07/15

infrastructure & works


RURAL RESIDENTIAL ROADS - NEW SUBDIVISIONS SD003
po box 220, maitland nsw 2320 SHEET 01 of 01
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS
450 SL72 MESH
70 Min. 60mm COVER
30 150 30

40
150
20 10

30

250
230
210

80

80
260 210
200 900
KERB ONLY or BARRIER KERB EDGE RESTRAINT
MOUNTABLE KERB (SM) DISH GUTTER
(KS)
(SF) (MODIFIED SB)

NOTE:
1. ALL DIMENSIONS IN MILLIMETRES
2. CONCRETE TO BE 32 MPa UNLESS OTHERWISE SPECIFIED
3. ALL EXPOSED CORNERS RADII 10mm UNLESS SPECIFIED OTHERWISE
4. MINIMUM THICKNESS OF CONCRETE TO BE 150mm

NOM. FACE OF KERB

OF KERB
150
150 215 30 450

NOM. FACE

40

110
R 30 t

75
P

100
0 Low
R 300
250

150 Min
150 Min

190
190
600 600
ROLL KERB & GUTTER
(MODIFIED RT) STANDARD KERB & GUTTER
(MODIFIED SA)

maitland city council STANDARD KERB PROFILES Rev: 23/07/2019


infrastructure & works
po box 220, maitland nsw 2320
SD004
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
FOOTPATH GRADES MAY BE ADJUSTED TO ACHIEVE
COMPLIANT DRIVEWAY GRADES.
MAXIMUM GRADE FOR CONNECTING RAMPS SHALL
BE 8:1 FOR 1.5m OR 14:1 FOR LONGER ADJUSTMENTS
THE FOOTPATH IS TO REPLACED WITH A MINIMUM
WIDTH OF 1.5m. COLOUR & FINISH TO MATCH
EXISTING FOOTPATH. MAXIMUM CROSSFALL ON
FOOTPATH SECTION IS 2.5%

LOW LEVEL FOOTPATH CROSSING HIGH LEVEL FOOTPATH CROSSING


NOTE:
1. MINIMUM WIDTH OF THE FOOTPATH SHALL BE 1.50m IRRESPECTIVE OF
EXISTING FOOTPATH WIDTHS.
2. ALL FINISHED SURFACE LEVELS OF THE FOOTWAY CROSSING SHALL
PROVIDE SATISFACTORY VEHICULAR ACCESS TO AS2890.1 OR BETTER.
THIS SHALL BE AT ALL POINTS OF THE FOOTWAY CROSSING PROFILE
FROM THE KERB SIDE LANE TO BEYOND THE PROPERTY BOUNDARY.
3. FINISHED SURFACE LEVELS SHALL COMPLY TO SD008.
4. VARIATIONS TO THESE STANDARDS WILL REQUIRE INSPECTION &
ACCEPTANCE BY COUNCIL'S APPROVING OFFICER.
5. REFER TO SD010 AND SD012 FOR LAYBACK, CONCRETE,
Pro REINFORCEMENT & SUB-BASE DETAILS. Pro
per per
ty B 6. STONE, PAVER OR FLAG DRIVEWAY SURFACES ARE NOT PERMITTED ty B
WITH THE FOOTWAY AREA. o
o
to unda 7. CONCRETE STRIP DRIVEWAYS ARE ONLY PERMITTED IN DESIGNATED
% toundar
.5 % ry HERITAGE AREAS .5 y
+17-10% +17-10%
50

50
% %
2.5
1.

1.
2.5
% 5 %
o8 1.5 to 8
55

t
1.

% %
2.5 2.5

M
MA INIM MAMINIM

Ex
is
XIM UM XIM UM

t in
g
UM WID UM W

Fo
WI IDTH

ot
WI TH

p
DT 2

at
DT 27 TYPICAL DRIVEWAY

h
H 6 00 TYPICAL DRIVEWAY H 6 700
000 mm UPRIGHT (SA) KERB 000 mm
mm ROLL (RT) KERB mm
NO FOOTPATH EXISTING CONCRETE FOOTPATH

maitland city council FOOTWAY DRIVEWAY CROSSINGS Rev: 23/07/2019


infrastructure & works
po box 220, maitland nsw 2320
GENERAL ARRANGEMENT SD007
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
FOOTWAY BUILDING SETBACK
TRANSITION 1 TRANSITION 2
1500 2800 VARIABLE 1400
SEE NOTES 1 & 2. SEE NOTES 3. SEE NOTES 1 & 2.
BACK OF ROLL TOP KERB

+12.5%
BACK OF KERB LAYBACK
NOMINAL FACE OF KERB

BOUNDARY
ROADWAY

+25%

POSITIVE GRADE TO
+17.5% DRAIN WATER AWAY

490
Roll top +50mm to +160mm FROM GARAGE FLOOR
Layback +31mm to +100mm +2.5% +40mm Max.
-10%
-22.5%
4% GRADE WHERE

140
THERE IS NO FOOTPATH

3200 -15%
FOOTWAY CROSSING - REFER TO SD007
TRANSITION 1 TRANSITION 2
1400 VARIABLE 2800 500
SEE NOTES 1 & 2. SEE NOTES 3. SEE NOTES 1 & 2.

LONGITUDINAL SECTION
NOTE:
1. CONFORMS TO AS2890.1-2004 GROUND CLEARANCE TEMPLATE FIGURE C1 B85 VEHICLE - MAXIMUM 2.8m WHEELBASE, MINIMUM 120mm
GROUND CLEARANCE.
2. PROFILES WITH GRADES LESS THAN THE MAXIMUM MAY NOT REQUIRE TRANSITIONS OR MAY HAVE ALTERNATE TRANSITION
TREATMENTS.
3. CHANGES OF GRADE BETWEEN SECTIONS SHALL NOT EXCEED 15% IN SAGS OR 12.5% OVER CRESTS.
4. MINIMUM LENGTH OF TRANSITION SHALL BE 2.8m FOR A POSITIVE CHANGE IN GRADE AND 1.4m FOR A NEGATIVE CHANGE IN GRADE.
5. MAXIMUM GRADE SHALL BE 25% (1 in 4) WITHIN THE PROPERTY.
6. FOR APPROVAL, DESIGN PROFILES SHALL SHOW EXISTING & FINISHED SURFACE LEVELS AT KERB, AT CHANGES OF GRADE & AT GARAGE
FLOOR OR PARKING AREA.
7. PROFILE TO BE APPLIED TO "WORST CASE" SIDE OF DRIVEWAY BEING SIDE WITH SHORTEST LENGTH, AND/OR GREATEST HEIGHT
DIFFERENCE BETWEEN KERB AND GARAGE FLOOR LEVEL

maitland city council DRIVEWAY PROFILES Rev: 08/04/2019

infrastructure & works


RECOMMENDED MAXIMUM GRADES SD008
po box 220, maitland nsw 2320 SHEET 01 of 01
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS
NOTE:
1. ALL DIMENSIONS IN METRES. DWELLING
0.9m GARAGE
2. A CLEAR ZONE FOR SIGHT DISTANCE MUST BE
MAINTAINED FOR A DISTANCE OF 2.5m ALONG
THE SIDE BOUNDARY. MAXIMUM OFFSET LINE
3. SEE AS2890.1-2004 FOR ACCESS RESTRICTION
POINTS FOR OTHER ACCESS TYPES.

BOUNDARY

6.0m
2.5m
ALLOWANCE FOR
2.70 - 6.00
SIGHT DISTANCE

1.5m
Note 2
BOUNDARY

MINIMUM CLEARANCE FROM SERVICE PILLAR


EDGE OF DRIVE TO SERVICE
SERVICE POLE TP
FIXTURE - 300mm
FOOTWAY

PEDESTRIAN
RAMP
KERB INLET PIT

SS
CE
TP

AC
NO
0.3 0.3 2.70 - 6.00 0.3 0.3 6.0m
NO ACCESS NO ACCESS

UPRIGHT 'SA' KERB ACCESS RESTRICTION - INTERSECTIONS

NOTE:
2.70 - 6.00m 2.70 - 6.00m

BOUNDARY BOUNDARY

PEDESTRIAN ROLL KERB TO 'SA' KERB TRANSITION


ROLL-FORMED KERB GRATE
RAMP VARIABLE LENGTH

EXISTING
1.00 1.00 2.70 - 6.00 0.90 1.00 2.70 - 6.00 1.00 KERB INLET PIT
NO ACCESS NO ACCESS NO ACCESS

ROLL 'RT' KERB WITH KERB GRATE ROLL 'RT' KERB WITH 'SA' KERB INLET
maitland city council DRIVEWAY CLEARANCES Rev: 22/07/2019
infrastructure & works
po box 220, maitland nsw 2320
OBSTACLES & OFFSETS SD009
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
RESIDENTIAL DRIVEWAY
MESH 400N12 DOWELS @ 300 c/c.
SEE SECTION C-C

C
DRILLED & EPOXIED 200mm INTO

-
EXISTING KERB
2700 Min. DRIVEWAY (Residential) 400N12 DOWELS @ 300 c/c. EXIST ROLLTOP KERB

125
DRILLED & EPOXIED 200mm
6000 Max. DRIVEWAY (Residential) INTO EXISTING

BACK OF KERB
SECTION C-C - ROLL ('RT') KERB
RESIDENTIAL

LIP OF KERB
PLAN - ROLL ('RT') KERB RESIDENTIAL DRIVEWAY 450
C
-

RESIDENTIAL ONLY

90
DEEP TOOL JOINT 25mm 20mm STEP
MESH 400N12 DOWELS @ 300 c/c.
SEE SECTION B-B DRILLED & EPOXIED

125
B
-

200mm INTO EXISTING


600 2700 Min. DRIVEWAY (Residential) KERB
6000 Max. DRIVEWAY (Residential)
400N12 DOWELS @ 300 c/c. DRILLED & BREAK OUT LINE

450
EPOXIED 200mm INTO EXISTING KERB SEE NOTE 2.
BACK OF KERB

FACE OF KERB SECTION B-B - UPRIGHT ('SA') KERB


RESIDENTIAL

LIP OF KERB
B
-

PLAN - UPRIGHT ('SA') KERB COMMERCIAL/INDUSTRIAL DRIVEWAY 450 450


FOR RESIDENTIAL AND COMMERCIAL

90
DEEP TOOL JOINT 25mm

NOTE: 20mm STEP

150
1. ALL DIMENSIONS IN MILLIMETRES
2. ALL CONCRETE TO BE 32MPa
3. SAWCUT BREAKOUT LINE TO MINIMUM DEPTH OF 75mm (NO MASTIC JOINTS
PERMITTED).
4. PROVIDE FULL DEPTH EXPANSION JOINT AT BOUNDARY LINE.
5. FOR COMMERCIAL AND INDUSTRIAL ACCESSES - WIDTH AND LAYOUT ARE
SIZED TO SUIT TURNING MOVEMENTS OF DESIGN VEHICLES.
SECTION B-B - UPRIGHT ('SA') KERB
COMMERCIAL/INDUSTRIAL

maitland city council DRIVEWAYS AND KERB LAYBACKS Rev: 22/07/19


infrastructure & works
po box 220, maitland nsw 2320
CONSTRUCTION DETAILS SD010
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
2700 DRIVEWAY (Min)

100 125
2700 DRIVEWAY (Min.) 32MPa CONCRETE
100mm COMPACTED GRAVEL BASE
1500 FOOTPATH (Min.) SL72 MESH PLACED CENTRALLY
COMPACTED SUBGRADE
2500 SHARED PATH (Min.)
SHARED DRIVEWAYS & ACCESSWAYS

125
INCLUDING MAINTENANCE VEHICLE ACCESS

50
32MPa CONCRETE SAND
SL72 MESH PLACED CENTRALLY COMPACTED SUBGRADE

RESIDENTIAL DRIVEWAYS, CYCLEWAYS & FOOTPATHS

150
125
32MPa CONCRETE
NOTE: 125mm COMPACTED GRAVEL BASE
2 x SL72 MESH - Min 40mm COVER
1. ALL DIMENSIONS ARE IN MILLIMETRES.
2. PROVIDE TRANSVERSE EXPANSION JOINTS AT 8.0m INTERVALS WITH R12 DOWELS, 300mm COMPACTED SUBGRADE
LONG AT 300mm CENTRES. REFER TO SD025 SHEET3 - JOINT FILLER SHALL BE FULL DEPTH
3. PROVIDE TOOLED DUMMY JOINTS AT 2.0m INTERVALS FOR PAVEMENTS LESS THAN 2.0m WIDE COMMERCIAL / INDUSTRIAL DRIVEWAY
AND AT 4.0m INTERVALS FOR PAVEMENTS UP TO 3.0m WIDE. CUT EVERY 2nd BAR AT JOINT
4. JOINTS WITH EXISTING CONCRETE FOOTPATHS TO BE DOWELLED WITH R12 DOWELS, 300mm
LONG AT 300mm CENTRES.
30mm AC10 OR 14/7 TWO COAT SPRAY SEAL
5. ALL DISTURBED EARTH OR GRASSED AREAS TO BE TURFED.
6. FOOTPATH WIDTHS TO SD001.

200
7. LAYBACKS AND CONNECTIONS TO SD010.
8. RURAL DRIVEWAY TO SD013.
9. KERB RAMP CONNECTIONS TO SD019.
10. CYCLEWAY AND FOOTPATH FINISH TO BE "LIGHT BROOM".
200mm THICK ROAD BASE
RURAL DRIVEWAY

maitland city council DRIVEWAYS, FOOTPATHS AND CYCLEWAY Rev: 22/07/19


infrastructure & works
po box 220, maitland nsw 2320
CONSTRUCTION DETAILS SD012
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
AC PLUG - SEE NOTE BELOW

A
-
SEE SD008 FOR DRIVEWAY GRADES
SEE SD10/12 FOR CONCRETE
REQUIREMENTS
ROADWAY

TYPICAL TABLE DRAIN


MODIFIED TABLE DRAIN TO
OFFSET OF PIPE DETERMINED BY COVER
2700 Min. / 6000 Max. MATCH PIPE ALIGNMENT
MIN. 125mm FOR CONCRETE DRIVEWAY
Boundary MINIMUM PIPE SIZE 375Ø MIN. 150mm FOR GRAVEL/SPRAY SEAL DRIVEWAY
SIZE & CLASS DETERMINED
BY QUALIFIED ENGINEER SECTION A-A
8000m

TOOLED DUMMY JOINT

STANDARD HEADWALL ON DEPARTURE SIDE


GATE SETBACK

USE SLOPED HEADWALL WHERE HEADWALL


FALLS WITHIN CLEARZONE FOR OPPOSING LANE
DRIVEABLE HEADWALL TOOLED DUMMY JOINT
ON APPROACH SIDE

TOOLED DUMMY JOINT


3600 Min / 7100 Max
1500

Edge of Bitumen/Formation
1500
A
-

100AC PLUG BETWEEN END OF CONCRETE DRIVEWAY & EDGE OF BITUMEN


(NOT REQUIRED FOR GRAVELLED/SPRAY SEALED DRIVEWAYS)
PLAN

maitland city council RURAL DRIVEWAYS Rev: 04/08/2019


infrastructure & works
po box 220, maitland nsw 2320
PIPED CROSSING SD013
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
A
-
EXISTING PAVERS RELAYED OVER SUPPORT SLAB

SUPPORT SLAB UNDER PAVERS AT DRIVEWAY ONLY

NOTE
PAVED FOOTPATH 1. EXISTING KERB STONES ARE NOT TO BE DISTURBED
2. FOR HERITAGE AREAS, ALL EXPOSED CONCRETE TO BE
"MORPETH MIX"
3. ALL CONCRETE TO BE 32MPa
4. CONCRETE STRIPS & FOOTPATHS TO COMPLY TO SD010/12
5. ALL FORMWORK & DEBRIS TO BE CLEARED FROM
WATERWAY AFTER COMPLETION
600 900 600

3 000 Min (2 x 1 500 Units)


2 700 Min.

B
CONCRETE

-
3 000 max. DRIVEWAY

CONCRETE KERB BRIDGE BY STONE KERB


'SA' KERB
PROPRIETARY CONCRETE 'SA' KERB
STRUCTURAL ENGINEER KERB BRIDGE

AC INFILL

CONCRETE EDGE BEAM


PLAN 150w x 200h - 32MPa
'AC' PLUG BETWEEN END OF CONCRETE

B
DRIVEWAY & EDGE OF BITUMEN

-
600
PLAN (NOT REQUIRED FOR GRAVELLED/SPRAY PROPRIETARY CONCRETE
A
-

EXISTING PAVERS RELAYED SEALED DRIVEWAYS) KERB BRIDGE


OVER SUPPORT SLAB AC INFILL

TYPICAL KERB BRIDGE TREATMENT BY 1 000 CONCRETE EDGE BEAM


EXISTING 'SA' KERB 150w x 200h - 32MPa
STRUCTURAL ENGINEER
SUPPORT SLAB UNDER
PAVERS AT DRIVEWAY ONLY SECTION A-A EXIST STONE KERB
SECTION B-B

TYPICAL KERB CROSSING FOR STONE KERBS IN HERITAGE AREAS KERB CROSSING FOR UPRIGHT 'SA' KERBS

maitland city council KERB CROSSINGS Rev: 08/04/2019


infrastructure & works
po box 220, maitland nsw 2320
SD014/15
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
1500 1550

300
ALIGN RAMPS & PATTERNS TO

1500
Min.
OPPOSITE RAMP

TYPICAL FOOTPATH TREATMENT AT


INTERSECTIONS

15
00
1520 UPRIGHT 'SA' KERB
Max.

1500
1500
Min.

1550
ROLL 'RT' KERB
Max.
1520

1500
Min.

1500
Min. RAMP & FOOTPATH LAYOUT
NEW WORKS
RAMP & FOOTPATH LAYOUT
EXISTING KERB RETURNS

maitland city council FOOTPATH & KERB RAMP LOCATIONS Rev: 22/07/2019
infrastructure & works
po box 220, maitland nsw 2320
AT INTERSECTIONS SD019
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 02
NOTE:
1. JOINTS TO EXISTING PAVEMENTS TO BE DOWELLED WITH
300R12 DOWELS @ 300c/c
2. ALL DISTURBED EARTH OR GRASSED AREAS TO BE TURFED DOWEL JOINT WITH 'JOINTEX' FILLER STRIP
3. NEW SECTIONS OF FOOTPATH TO BE CONSTRUCTED IN 300R12 @ 300c/c DOWEL JOINT WITH
750
ACCORDANCE WITH SD10/12 300R12 @ 300c/c
EXISTING FOOTPATH
1:8 MAX START RAMP AT INVERT
ALIGN RAMPS & PATTERNS TO NO LIP
OPPOSITE RAMP
CONCRETE FOOTPATH

TYPICAL SECTION - ROLL 'RT' KERB


CONCRETE FOOTPATH

1520 Max.
1:8 MAX 1:8 MAX
DOWEL JOINT WITH
'JOINTEX' FILLER STRIP
GRASSED 300R12 @ 300c/c
SA KERB 1520 Max.
AREA NO LIP
1500 1500 MIN 1500 EXISTING FOOTPATH DOWEL JOINT WITH
SA KERB 1:8 MAX 300N12 @ 300c/c
600 1500 MIN 600 RAMP IN FULL CONCRETE CHEMSET INTO KERB
FOOTWAY 32MPa CONCRETE
RAMP IN GRASSED
CROSSFALL -2.5% MAX. TO KERB SL72 MESH
FOOTWAY PLACED CENTRALLY 50mm SAND BEDDING

32MPa CONCRETE
TYPICAL SECTION - UPRIGHT 'SA' KERB

125
SL72 MESH PLACED

50
SL72 MESH
CENTRALLY PLACED CENTRALLY
CONCRETE FOOTPATH SAND
'JOINTEX' FILLER STRIP

75
COMPACTED SUBGRADE
DOWEL JOINT WITH 600
1520 Max.

TYPICAL SECTION 300R12 @ 300c/c NO LIP


1:8 MAX
CYCLEWAYS & FOOTPATHS EXISTING FOOTPATH 1:8 MAX

FOR CONCRETE FOOTPATHS:


DOWEL JOINT WITH
600 1 500 600 1. PROVIDE TRANSVERSE EXPANSION JOINTS EVERY 32MPa CONCRETE 300N12 @ 300c/c
8.0m WITH 300R12 DOWELS @ 300 c/c
50mm SAND BEDDING CHEMSET INTO KERB
2. PROVIDE TOOLED DUMMY JOINTS EVERY 2.0m FOR
PAVEMENT LESS THAN 2.0m WIDE & 4.0 m FOR TYPICAL SECTION - LOW LEVEL FOOTPATH
RAMP - ROLL 'RT' KERB PAVEMENTS OVER 2.0m WIDE
3. FINISH TO BE 'LIGHT BROOM'. BROOM OVER JOINTS

maitland city council KERB RAMPS Rev:08/04/2019


infrastructure & works
po box 220, maitland nsw 2320
CONSTRUCTION DETAILS SD019
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 02 of 02
R8-2A (LOCAL ROAD)
INSTALL PROPRIETARY BOLLARDS AT R1-2 SPECIAL (375 WIDE) R8-2B (MAIN ROAD)
BOTH ENDS OF PATH
MAX. SPACING 1.4m - SEE NOTE 5 2.5m
W6-8B (450 x 450)

SHARED PATH
FOR PEDESTRIAN PATHS, BOLLARDS
ARE TO BE PLACED EITHER SIDE OF THE
END & 100mm IN FROM THE THROUGH
BOUNDARY
CENTRE BOLLARD TO BE REMOVABLE
R1-2 SPECIAL
(375 WIDE)

2.5m
SHARED PATH
FOOTPATH
R8-2A (LOCAL ROAD)

REFER TO SD019 FOR RAMP DETAILS REFER TO SD019 FOR


RAMP DETAILS
KERB NO KERB
STOPPING
NO
STOPPING 20.0m 10.0m

TREATMENT AT FOOTPATH CROSSINGS TREATMENT AT INTERSECTIONS


R5-400(L)
NOTE:
R5-400(R) 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE SHOWN.
2. PAVEMENT MARKINGS MAY BE SUBSTITUTED FOR SIGNS.
3. REFER TO SD012 FOR CYCLEWAY PAVEMENT DETAILS.
4. ALL REGULATORY SIGNAGE SHALL BE APPROVED BY COUNCIL'S
LOCAL AREA TRAFFIC COMMITTEE
5. WHERE PATHWAYS ARE USED FOR MAINTENANCE OR EMERGENCY
VEHICLE ACCESS THE BOLLARDS ARE TO BE REMOVABLE & LOCKABLE

maitland city council SHARED FOOTPATH / CYCLEWAY SIGNAGE Rev:22/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD020
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
R5-20
"BUS ZONE"
BUS STOP SIGN
5
2 .2

Fo
Ro

ot
TACTILE MARKERS

w
adw

2.

ay
70
%
2.5 ay
MINIMUM CLEARANCE

11 e N
Se
BETWEEN EDGE OF PATH &

.5 ot
0 e
BACK OF SHELTER
BUS STOP SIGN

2
0.3
75
0 30.
0.
MINIMUM CLEARANCE 00

12
BETWEEN INVERT OF KERB

.5
m
Bu
& FRONT OF ROOF
0.

s
30

1 - URBAN BUS STOP 5 6.0


0.7 0 0
1.5

Se
EXISTING KERB - NO SHELTER

e
N
ot
e
2
BUS STOP SIGN R5-20
"BUS ZONE"

BUS ZONE - SIGNAGE


1.
50
BUS STOP SIGN

5%
Sh

2.
elte
1.2 r TACTILE MARKERS
0 2 .7 TACTILE MARKERS
0
5
0.7
5%

0.3
2.

2.7 0 5
0 0.1 5
0.3 0.7
0
PARTIAL 'SA' KERB 5
2.2 2 - URBAN BUS STOP - SHELTER NOTE
0.
30

1. DIMENSIONS ARE BASED ON BUS STOP SIGN POLE & BACK OF KERB
EXISTING KERB 2. BUS STOP SIGN TO BE NOMINATED BY COUNCIL'S TRAFFIC SECTION
0.
30

3. ALL SIGN POLES TO BE FIXED IN V-LOCK MOUNTING SOCKETS


4. APPROACH & DEPARTURE ZONE LENGTHS MAY BE AFFECTED BY
3 - RURAL BUS STOP ADJACENT TRAFFIC FACILITIES
5. DIMENSIONS WILL VARY DEPENDING ON SIZE OF SHELTER
NO KERB - NO SHELTER 6. ALL CONCRETE TO BE 32MPa & 150mm THICK WITH SL72 MESH PLACED
CENTRALLY & DOUBLED UNDER SHELTER AREA
7. WHERE THROUGH ACCESS 1.50m WIDE IS NOT AVAILABLE BEHIND THE
SHELTER, THE SHELTER MAY BE MOVED BACK TO THE BOUNDARY.

maitland city council BUS STOP FACILITIES - RURAL & URBAN SITES Rev: 17/05/18
infrastructure & works
po box 220, maitland nsw 2320
WITH & WITHOUT SHELTERS SD023
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
FULL DEPTH AC INFILL
= =
PROVIDE EDGE THICKENING

IN
MIN

0M
600

60
EDGE THICKENING

LJ LKJ

LJ
TCJ TCJ
= STEEL REINFORCING
FABRIC MINIMUM 50
TOP COVER

8500
5500

LKJ

LKJ
STEEL REINFORCING
LJ
FABRIC 50 TOP COVER
TCJ
TCJ TCJ
ADDITIONAL JOINTS GENERALLY IN

LJ
=
ACCORDANCE WITH DETAIL 'A' =
(SD025-3) ARE TO BE PROVIDED
LJ
WHERE NOMINATED BY THE LKJ
ENGINEER PENDING ISLAND LAYOUT EDGE THICKENING
AND CONSTRUCTION METHODS
LOCATE JOINT PERPENDICULAR TO CURVE &
APPROXIMATELY MID-ARC.
JOINT CONTINUOUS THROUGH KERB & GUTTER.

FULL DEPTH AC INFILL

'T' INTERSECTION THRESHOLD PLAN MID-BLOCK RAISED THRESHOLD PLAN


LEGEND
IJ ISOLATION JOINT WITH SUBGRADE BEAM
TCJ TRANSVERSE CONTRACTION JOINT
CJ CONSTRUCTION JOINT
LJ LONGITUDINAL JOINT * PEDESTRIAN RAMPS
OMITTED FOR CLARITY
LKJ LONGITUDINAL KERB JOINT
EJ EXPANSION JOINT
REFER TO SD025-3 FOR JOINT DETAILS.

maitland city council CONCRETE ACCESSES & THRESHOLDS Rev:01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD025
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 04
LEGEND
IJ ISOLATION JOINT WITH SUBGRADE BEAM
TCJ TRANSVERSE CONTRACTION JOINT
CJ CONSTRUCTION JOINT
LJ LONGITUDINAL JOINT
LKJ LONGITUDINAL KERB JOINT PROVIDE 2 x N12 BARS IN
EJ EXPANSION JOINT TCJ VERTICAL PLANE ADJACENT TO
REFER TO SHEET SD025-3 FOR JOINT
PITS ETC WHERE NO JOINT IS
DETAILS.
MIN PROJECTED INTO THE PAVEMENT
700

IJ
STEEL REINFORCING FABRIC TCJ

J
LK
MIN COVER 50mm IJ ALL ROUND DRAINAGE PITS OR
K&G
OTHER PROJECTIONS INTO
ROAD

LKJ PAVEMENT
IJ
EJ

IJ
MIN 6m IJ
LJ

TCJ

TCJ

TCJ
MAX 12m
CJ

EDGE THICKENING TO ALL


LOCAL

LJ LJ FREE EDGES.
TCJ PARKING BAY TCJ
TCJ

00
PROVIDE LJ TO PAVEMENT WHERE

N7
WIDTH EXCEEDS 5.5m OR AS
PLAN

MI
SHOWN IN PARKING BAYS.
NOTE: LJ CAN ONLY BE
TERMINATED AT CJ OR IJ
TCJ
STEEL REINFORCING FABRIC
AS PER TABLE SD025-3
300

CONCRETE SPECIFICATION
1 SUB-BASE & THICKNESS BY
1 DESIGNING ENGINEER
300

EDGE THICKENING DETAIL

maitland city council CONCRETE ACCESSWAYS & THRESHOLDS Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
JOINTS & LAYOUTS SD025
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 02 of 04
SAW CUT AND PROVIDE SEALANT SAW CUT AND PROVIDE SEALANT
RESERVOIR AND SEALANT, STEEL REINFORCING RESERVOIR AND SEALANT,
SEE DETAIL 'A' SD025-4 FABRIC MINIMUM 50 TOP 75 TYP SEE DETAIL 'A' .
75 TYP
COVER

SEE SD025-4
SEE SD025- 4
NOTE 7
NOTE 7

= = 1000N12 @ 800 c/c


TRANSVERSE CONTRACTION JOINT (TCJ)
LONGITUDINAL JOINT (LJ)

SEALANT RESERVOIR STEEL REINFORCING FABRIC


SEE SD025-4 FROM PAVEMENT SLAB BENT
NOTE 7 FALL UP 75 FROM EDGE OF SLAB &
PROJECTING 50 INTO KERB
SEE SD025-4
NOTE 7

= = 1000N12 @ 800 c/c OR


FORMED SLAB EDGE TO DOWEL AS DETERMINED INTEGRAL KERB
BE CORRUGATED BY ENGINEER
CONSTRUCTION JOINT (CJ) 1000N12 @ 800 c/c, GALVANISED - TO
SEE SD025-4 75 TYP BE INSERTED IN KERB, RAKED AT AN
NOTE 7 ANGLE & BENT AT THE LIP LINE INTO
FALL
BASE.
PROVIDE 10mm THICK APPROVED
EXPANSION MATERIAL FULL DEPTH.
75 TYP TOP 25mm TO BE APPROVED SEALANT.

SEE SD025-4
LONGITUDINAL KERB JOINT (LKJ)
NOTE 7
PROVIDE 10mm THICK APPROVED
= = PROVIDE DOWEL CAP TO ALLOW EXPANSION MATERIAL FULL DEPTH.
FORMED SLAB EDGE * 25mm EXPANSION TO MAX 200 TOP 25mm TO BE APPROVED SEALANT.
REFER TO DOWEL THICK BOND BREAKER BETWEEN SLABS.
=
EXPANSION JOINT (EJ) DIMENSION TABLE
= SUBBASE SUBGRADE BEAM TO BE 500 WIDE
DOWEL TO BE DEBONDED
ADJACENT TO PITS OR PROJECTIONS
800 INTO THE PAVEMENT.
SUBGRADE

ISOLATION JOINT (IJ) WITH SUBGRADE BEAM

maitland city council CONCRETE ACCESSWAYS & THRESHOLDS Rev: 08/04/2019

infrastructure & works


JOINT DETAILS SD025
po box 220, maitland nsw 2320
MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 03 of 04
email: [email protected]
8-10 8-10 THE VERTICAL FACE OF THE
ENSURE SAW CUT IS 1/3
DEPTH OF PAVING AT JOINT IS TO BE CLEANED &
SEALED.

5
EDGE THICKENING.

*
NOTE:
*

OF CONCRETE PAVING

OF CONCRETE PAVING
1. ALL DIMENSIONS IN MILLIMETRES SEALANT MATERIAL
2. ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH MAITLAND CITY (APPROVED FIELD MOULDED

1/3 THICKNESS

1/3 THICKNESS
COUNCIL ENGINEERING REQUIREMENTS. SILICONE SEALANT)
3. ALL EXPOSED CONCRETE EDGES TO BE ROUNDED TO A 5mm RADIUS.
4. ALL DOWELS TO BE EFFECTIVELY DEBONDED WHERE SPECIFIED. TAPE BOND BACKER
5. SAW CUTS TO BE CARRIED OUT AT A TIME TO ENSURE CRACKS ARE INDUCED 3 BREAKER ROD 3
AT THE JOINT LOCATIONS AND TO MINIMISE SPALLING.
UNPLANNED CRACKS IN SLABS MAY RENDER THEM UNACCEPTABLE. INITIAL SAW CUT ENSURE JOINT
6. PROVIDE APPROVED CURING COMPOUND TO FINISHED CONCRETE SURFACE IS ADEQUATELY CLEANED OF ALL
IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. MATERIAL PRIOR TO PLACEMENT
7. REFER TO STEEL REINFORCING FABRIC TABLE. OF TAPE BOND BREAKER OR
8. ALL DOWELS & DEFORMED BARS TO BE PLACED CENTRALLY. BACKING ROAD.
9. PAVEMENT THICKNESS, JOINT LAYOUT & TYPE SUBJECT TO GEOTECHNICAL
INVESTIGATION, DESIGN & APPROVAL BY COUNCIL'S REPRESENTATIVE. RUBBER SPLINE TO BE PLACED
INDUCED CRACK IMMEDIATELY AFTER INITIAL CUT IS MADE INDUCED CRACK
10. THESE STANDARDS ARE TO BE READ IN CONJUNCTION WITH THE "CEMENT &
CONCRETE ASSOCIATION OF AUSTRALIA". CONCRETE PAVEMENT DESIGN & CLEANED OUT.

11.
FOR RESIDENTIAL STREETS (T51).
MINIMUM COMPRESSIVE STRENGTH (FC) TO BE MIN. 32MPa AT 28 DAYS (INCL. DETAIL 'A' * DEPTH AS PER
MANUFACTURERS
ADJACENT KERB & GUTTER & SUBGRADE BEAM). RECOMMENDATIONS
12. PAVEMENT EDGE THICKENING WILL BE REQUIRED WHERE NO KERBING IS
ALTERNATE METHODS
PROPOSED UNLESS OTHERWISE APPROVED.
13. LATERAL SUBSOIL LINES WILL BE REQUIRED AT THE INTERFACE OF FLEXIBLE MESH DOWELS
AND RIGID PAVEMENTS IN ADDITION TO COUNCIL'S STANDARD
REQUIREMENTS. CONCRETE STEEL REINFORCING CONCRETE DOWEL DOWEL
14. WHERE LONGITUDINAL GRADES EXCEED 15% OR PROTECTION OF ADJACENT THICKNESS FABRIC THICKNESS DIAMETER LENGTH
PAVEMENTS OR STRUCTURES IS NECESSARY, SLAB ANCHORS (ANCHOR (mm) (AS 1204) (mm) (mm) (mm)
BLOCKS) SHALL BE PROVIDED.
15. JOINTS IN KERBS SHALL BE OF ADEQUATE DEPTH TO ENSURE POSITIVE 165 min F82 or F828 165 min 28 450
CRACK INDUCTION (NOT TOOLED DUMMY JOINTS) & ARE TO BE LOCATED TO 175 F82 or F828 175 28 450
ALIGN WITH JOINTS IN ADJACENT PAVING OR K&G.
200 F82 or F828 200 33 450
16. ALL DEFORMED BARS TO BE GRADE 500Y.
ALL DOWELS PLACED AT 300mm CENTRES TO BE
GRADE 250R STEEL BARS

NOTE: ALL DOWELS WITHIN A JOINT ARE TO BE


ALIGNED PARALLEL WITH THE LINE JOINING
THE CENTROIDS OF ADJOINING SLABS.

maitland city council CONCRETE ACCESSWAYS & THRESHOLDS Rev:08/04/2019


infrastructure & works
po box 220, maitland nsw 2320
JOINT DETAILS SD025
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 04 of 04
DJ

TYPICAL WING TREATMENT FOR OPTIONAL CONCRETE THRESHOLD TYPICAL WING TREATMENT FOR
DJ
SMALL RADIUS KERB RETURNS LARGE RADIUS KERB RETURNS

Min.
1500
DJ DJ

DJ DJ DJ

'SB' DISH CROSSING


SEE SD004 PLAN
NOTE:
1. ALL DIMENSIONS IN MILLIMETRES
2. DISH DRAIN TO BE MINIMUM 150mm THICK, REINFORCED WITH SL72 MESH
PLACED CENTRALLY
3. WINGS TO BE FORMED & POURED INTEGRAL WITH KERB
4. ALL CONCRETE 32MPa
5. 'DJ' ALL JOINTS TO BE DOWELLED (400 N12 @ 300c/c)
6. KERB RAMPS DELETED FOR CLARITY. SEE SD019/1 & SD019/2 FOR
LOCATIONS

maitland city council CONCRETE DISH CROSSINGS AT Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
INTERSECTIONS SD026
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
R8
.0m
13.0m m

m
0.0

6.0
R1
m

13.0m
13.0m 13.0m 4.0

13
6.0m

6.0m
.0m
R8.0
m
.0m
°
90

R30 R1
4.0 5.0
m m

T-HEAD Y-HEAD MODIFIED T-HEAD


CIRCULAR HEAD

NOTE:
1. INCOMING WIDTHS DETERMINED BY ROAD CATEGORIES SETOUT IN THE ROAD DESIGN SECTION OF
COUNCIL'S "MANUAL OF ENGINEERING STANDARDS" .
2. NOTWITHSTANDING THE ABOVE DIMENSIONING, AUSTRALIAN STANDARD AS 2890.2 - PARKING
FACILITIES PART 2: OFF-STREET COMMERCIAL VEHICLE FACILITIES SHALL BE USED TO VERIFY
ADEQUATE MANOEUVRING AREA.
3. ALTERNATIVE LAYOUTS WILL BE CONSIDERED BY COUNCIL.

maitland city council CUL-DE-SAC OPTIONS Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD027
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
PROPRIETARY
BRACKET & CAP
1. ALL DIMENSIONS ARE IN MILLIMETRES.

STREET
2. SIGNS ARE TO BE ERECTED BY THE DEVELOPER UNDER
COUNCIL'S SUPERVISION.
600mm FROM FACE OF KERB 3. NON-STANDARD SIGNS MAY BE USED SUBJECT TO PRIOR
TO FACE OF BLADE APPROVAL BY COUNCIL.

70
TEXT 30mm
MAJOR ROAD

45

200
3000 Min.
MINOR

50mm NB GALVANISED 500 Min. - 1 200 Max. TEXT 65mm


STEEL POST
TEXT 100mm

FINGER BOARD
CROSS STREET INTERSECTION
V-LOCK BASE SOCKET IN

FACE OF KERB
CONCRETE PAVING

SIGN SPECIFICATION
SIGN COLOUR
STREET NAME BLADE :BLACK LETTERS ON WHITE REFLECTORISED
BRANCH

ANTI-TURNING PIN BACKGROUND


ROAD

DIRECTIONAL SIGN BLADE : BLACK LETTERS ON WHITE REFLECTORISED


BACKGROUND
MASS CONCRETE SIZE & SHAPE
SIGNS SHALL BE RECTANGULAR, HAVE A BLADE WIDTH OF
200mm, A MINIMUM LENGTH OF 500mm & MAXIMUM LENGTH
OF 1200mm.
1.8m POLE
REFLECTIVE MATERIAL
THROUGH ROAD THE BACKGROUND SHALL CONSIST OF CLASS 1 MATERIAL,
LAMINATED TO THE EDGE OF BLADE.
SIGN LOCATION LETTERING
1. STREET NAME SIGNS TO BE PROVIDED AT ROUNDABOUTS AND LETTERS & NUMERALS FOR STREET NAMES SHALL BE SERIES 'D',
300mm FROM FACE OF MAJOR INTERSECTIONS WHERE SHOWN ON THE APPROVED AS SPECIFIED IN AS1744,
KERB TO END OF BLADE ENGINEERING PLANS OR AS DIRECTED BY THE ENGINEER. WHERE THE TEXT PRODUCES A SIGN GREATER THAN 1200mm IN
2. SIGN POST LOCATIONS MAY BE VARIED BY THE ENGINEER WHERE LENGTH, THE LETTERING MAY BE MADE PROPORTIONALLY
"T" INTERSECTION POWER POLES OR SIMILAR OBSTRUCT VIEW. NARROWER BUT NOT NARROWER THAN SERIES 'C'.

maitland city council STREET NAME SIGN POSTING Rev: 15/03/2017


infrastructure & works
po box 220, maitland nsw 2320
SD029
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
OPTIONAL TURN LANE
KERB & GUTTER WITH SUPPORTING SHOULDER BEHIND.
DESIGN TO CONSIDER DOWNSTREAM DRAINAGE TREATMENT FROM KERB.

1. LAYOUT SHOWN IS TYPICAL ONLY PASSING LANE TREATMENT:


2. ALL DIMENSIONS, GRADES AND SIGHT DISTANCES SHALL BE 1. GRANULAR PAVEMENT MATERIAL.
DETERMINED FROM THE AUSTROADS 'GUIDE TO ROAD DESIGN" PART 4A 2. DEPTH SUBJECT TO TEST APPROVAL.
"WARRANTS FOR BASIC, AUXILIARY AND CHANNELISED TURN 3. TWO COAT BITUMEN SEAL OR ASPHALT AS DETERMINED
TREATMENTS" AND THE ROAD DESIGN SECTION OF COUNCIL'S MANUAL BY COUNCIL.
OF ENGINEERING STANDARDS 4. PROVIDE TABLE DRAIN IN CUTTING.
3. A DESIGN VEHICLE APPROPRIATE TO THE DEVELOPMENT &/OR TRAFFIC 5. SAWCUT EXISTING BITUMEN AT JOINT.
STATISTICS SHALL BE NOMINATED & THE ACCESS GEOMETRY BASED ON 6. ALL WORKS TO BE IN ACCORDANCE WITH COUNCIL'S
THAT VEHICLE'S TURNING PATHS MANUAL OF ENGINEERING STANDARDS.
4. GRADES, SIGHT DISTANCES, AFFECTED SERVICES & BOUNDARIES ACCESS ENTRY/EXIT TREATMENT:
SHALL BE CONSIDERED 1. GRANULAR PAVEMENT MATERIAL
5. LINEMARKING & SIGNAGE SUBJECT TO LOCAL TRAFFIC COMMITTEE 2. COMPACTED DEPTH MINIMUM 200mm
ASSESSMENT

4.
3.
2.
1.
ACCESS
GRANULAR
COMPACTED
TWO
PIPE DRAINAGE
COAT
ENTRY/EXIT
BITUMEN
PAVEMENT
DEPTH
MAY 200mm
FLUSH
BE
TREATMENT:
MATERIAL.
REQUIRED
(Min.).
SEAL. INCLUDING CONCRETE HEADWALLS.

3. TWO COAT BITUMEN FLUSH SEAL


4. WHERE PIPE CROSSING IS REQUIRED SEE
SD013-1 FOR HEADWALL DETAILS

maitland city council MINIMUM INTERSECTION TREATMENT FOR HIGH/HEAVY Rev: 08/04/2019
infrastructure & works
po box 220, maitland nsw 2320
TRAFFIC GENERATING DEVELOPMENTS SD031
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
MINIMUM DISTANCE
JOINT NOT TO BE LOCATED PAVEMENT DESIGN SUBJECT TO
UNDER WHEELPATH EDGE OF EXISTING PAVEMENT GEOTECHNICAL ASSESSMENT

KERB & GUTTER


SAWCUT EDGE AND MAKE SMOOTH 300 300 TOPSOIL & TURF EXPOSED AREAS
JUNCTION WITH EXISTING
3%
WEARING SURFACE
BASE COURSE

SUB-BASE
EXTEND PAVEMENT A MINIMUM OF
300mm INTO THE EXISTING PAVEMENT
STEP LAYERS IN ACCORDANCE WITH
GEOTECHNICAL ASSESSMENT
SUBSOIL DRAINAGE
REFER TO SD035

INSTALL SUBSOIL DRAINAGE IN


ACCORDANCE WITH
GEOTECHNICAL REPORT

TYPICAL SECTION
AREA OF NEW FULL DEPTH PAVEMENT

NOTE:
1. ALL DIMENSIONS IN MILLIMETRES
2. PAVEMENT JOINS NOT TO BE PLACED
UNDER WHEELPATHS.

maitland city council PAVEMENT WIDENING TO NEW KERB & GUTTER Rev: 08/04/2019
infrastructure & works
po box 220, maitland nsw 2320
SD032
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
20mm AGGREGATE IN 300mm
100mm SOCKED SUB-SOIL PIPE WIDE TRENCH TO SURFACE

1000
1000
2000
TOPSOIL & TURF
200

2000

PLAN
SANDY LOAM

20mm AGGREGATE IN 300mm


SECTION - ENTRY DRAIN WIDE TRENCH TO SURFACE
RAISED GRATE
3 000 3 000
300

150

350
100mm SOCKED SUB-SOIL PIPE
450

100mm SOCKED SUB-SOIL PIPE


LONGITUDINAL SECTION
maitland city council SILT TRAP & SWALE Rev: 01/07/15
infrastructure & works
po box 220, maitland nsw 2320
FOR UNSEALED HARDSTANDS SD034
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
TOPSOIL & TURF TOPSOIL & TURF TOPSOIL & TURF
COMPACTED GRAVEL COMPACTED GRAVEL COMPACTED GRAVEL
EXPOSED AREAS EXPOSED AREAS EXPOSED AREAS

BASE

SUB-BASE

SELECT MATERIAL
(AS REQUIRED)
4

4
600 Min.

600 Min.
5
BACKFILL ZONE
CLEAN GRADED FILTER SAND
OR GRADED AGGREGATE
SEE NOTE 2 5
HAUNCH AND SIDE
"SOCKED" SUBSOIL ZONE (MIN LEVEL)
PIPE 100Ø "SOCKED" SUBSOIL
50

WATER MAIN 600 5


300 PIPE 100Ø BEDDING MATERIAL
ZONE
TYPICAL INSTALLATION SHARED TRENCH
(WITH WATER MAIN)
STORMWATER TRENCH
(ALL STORMWATER PIPES)
BASE
NOTE: CONCRETE SURROUND
1. TYPE, LOCATION AND EXTENT OF ADDITIONAL BEHIND KERB
SUB-BASE
SUBSOIL DRAINAGE SHALL BE IN ACCORDANCE FITTED WITH SCREWED
WITH A GEOTECHNICAL CONSULTANT'S PLASTIC CAP
SELECT MATERIAL
ASSESSMENT.
(AS REQUIRED)
2. A NOMINAL SIZE AGGREGATE (10mm MAXIMUM)
MAY BE SUBSTITUTED FOR THE FILTER SAND 5
BACKFILL ZONE
3. FLUSH POINTS SHALL BE PROVIDED AT UPSTREAM
DEAD ENDS & CRESTS & AT MAXIMUM OF 60m PLASTIC OBLIQUE 'Y'
HAUNCH AND SIDE CONNECTOR 100 I.D
CTRS. "SOCKED" SUBSOIL ZONE (MIN LEVEL) 5
4. DEPTH MAY BE VARIED IN A ROCK SUBGRADE. PIPE 100Ø CLEANOUT PIPE
5. SEE THE CONSTRUCTION SECTION OF THE MANUAL
BEDDING MATERIAL
OF ENGINEERING STANDARDS FOR TRENCH
ZONE 5 SUBSOIL PIPE
MATERIAL SPECIFICATION. EACH ZONE MAY BE
ONE HOMOGENEOUS APPROVED MATERIAL.
FLUSH POINT
STORMWATER TRENCH UNDER ROAD
(ALL STORMWATER PIPES)

maitland city council SUB-SOIL DRAINAGE Rev: 22/07/2019


infrastructure & works
po box 220, maitland nsw 2320
SD035
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
FOR INSTALLATIONS INTO
MULTIPLE OUTLET EXISTING KERB - SAWCUT
SECTION MIN 300 WIDE -
SCABBLE CUT SURFACE &
APPLY BONDING AGENT PRIOR
TO PLACING 32MPa CONCRETE

300 Min
GALV. 150 x 50 x 4 RHS

FOR FOOTWAY DIMENSIONS


SEE SD001
BOUNDARY

FOR INSTALLATIONS UNDER EXISTING FOOTPATH


PLAN REMOVE FOOTPATH BETWEEN EXISTING JOINTS.
REPLACEMENT FOOTPATH IS TO BE DOWELLED INTO
EXISTING. COLOUR & FINISH TO MATCH EXISTING
PEG & STRING TO
CAPPED CONNECTOR 4.0% CROSSFALL ON
FOOTWAY WITH NO FOOTPATH +100mm ABOVE TOP OF KERB
1.55m FROM BACK OF KERB PROPRIETARY GALV.
1.0% 2.5% MAX. 75
6.5% METAL KERB OUTLET

'RT' KERB (Mod)


PROPRIETARY ADAPTOR BY DEVELOPER GALV. 150 x 50 x 4 RHS SEE SD004
90 ID HOUSE CONNECTION BY OWNER 1.0% GRADE TO KERB
GALV. SLEEVE 200mm LONG
TYPICAL SECTION - 'RT' KERB
4.0% CROSSFALL ON +75mm ABOVE TOP OF KERB
FOOTWAY WITH NO FOOTPATH 1.55m FROM BACK OF KERB
2.5% MAX 75 PROPRIETARY GALV.
5.0% METAL KERB OUTLET

'SA' KERB (Mod)


GALV. 150 x 50 x 4 RHS SEE SD004
TYPICAL SECTION - 'SA' KERB 1.0% GRADE TO KERB GALV. SLEEVE 200mm LONG

maitland city council KERB STORMWATER OUTLETS & KERB ADAPTER Rev: 01/07/15
infrastructure & works
po box 220, maitland nsw 2320
SD036
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
150 1500
600

75
300 N12 DOWELS @ 300 c/c
M ax.
2.5% MAX. 8:1 for 1.5m

MINIMUM 3000

150
300 N12 DOWELS

125
SL72 PLACED CENTRALLY @ 300 c/c
SL72 PLACED CENTRALLY

SECTION A-A A
-
A
-
SECTION B-B
TAPER TOP OF KERB TO REDUCE TRIP HAZARD
ENSURE 100mm MINIMUM FREEBOARD
TO PROPERTY BOUNDARY

4.0%

1% MIN
-
1300

NOTE:
1. DETAILS SHOWN ARE APPLICABLE AT
UPSTREAM ENTRIES TO FLOW PATHS
2.5%

2.5%
1500

ONLY. 8:1 FOR 1.5m MAX 8:1 FOR 1.5m MAX


4500

2. SHAPE AND GRADES OF FOOTPATH


AND PRAM RAMPS TO BE IN
ACCORDANCE WITH SD019-2.
3. REFER TO SD10 FOR JOINT LOW LEVEL FOOTPATH
REQUIREMENTS IN CONCRETE

8:1
SEE SECTION B-B & SD019-2
4.0%

PAVING. CREST
1700

4. FLOW PATH AND RAMP AREAS TO BE


FULLY CONCRETED.

8:1

600
DOWN
B
-

LOW POINT OPTIONAL ON-GRADE PIT

PLAN
maitland city council FOOTWAY FLOWPATH Rev: 08/04/2019
infrastructure & works
po box 220, maitland nsw 2320
SD037
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
15

RELFECTIVE WHITE
BACKGROUND

REFLECTIVE RED
TRIANGLE

BLACK RAINDROPS &

375
FIGURE

REFLECTIVE BLUE
DENOTING FLOOD
WATERS

BLACK BASE

690
OF FLOODWAY

12.5
BLACK LETTERING
FLOODWAY LETTERS 37.5mm

WARNING
17.5

RED LETTERING LETTERS 50mm


17.5
LETTERS 25mm
BLACK LETTERING 12.5
LETTERS 25mm
17.5
BLACK LETTERING LETTERS 25mm
12.5
LETTERS 25mm
22.5

NOTE: ALL LETTERING TO BE "E" SERIES

maitland city council FLOOD WARNING SIGNAGE Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD038
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
CORNER OF LINTEL LINTEL LENGTH LINTEL LENGTH
TO LINE UP WITH 300 SEE NOTE 3, SHEET 2. 300 300 SEE NOTE 3, SHEET 2. 300
INSIDE FACE OF PIT PRECAST LINTELS
D D
S2 JOINT S2
JOINT

A A B B
- - - -

EXPANSION JOINT DIRECTION OF FLOW DIRECTION OF FLOW DIRECTION OF FLOW


GRATE HINGE TO BE EXPANSION JOINT
LOCATED CLOSEST TO OUTSIDE EDGE OF FRAME
ONCOMING TRAFFIC D TO BE FLUSH WITH LIP LINE D
S2 S2

PLAN - ON GRADE PIT PLAN - SAG PIT


FOR ROLL KERB & GUTTER LINTEL TO BE
RAISED 30mm. TRANSITION OVER 900mm.

CL PIT
GUTTER TRANSITON LINTEL LENGTH + 600 GUTTER TRANSITON
900 SEE NOTE 3, SHEET 2. 900 1/2 LINTEL LENGTH 1/2 LINTEL LENGTH

175 75 175

LINTEL SUPPORT PAD

RACE DEPTH
RACE DEPTH
MIN. 400

MIN. 400
R150

MIN. 150

MIN. 150
MIN. 150

R150

SEE NOTE 10, SHEET 2

900
150 SEE NOTE 8, 150
150

SHEET 2. SEE SHEET 39-2


RACE POURED ON FOR SECTION D-D
SECTION A-A TOP OF PIT WALL
SECTION B-B

maitland city council GRATED GULLY PITS WITH Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
EXTENDED KERB INLETS SD039
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 02
15
GRATE & FRAME WITH FLAT SKIRT CLEARANCE TO ALLOW

TK
200 BASE ON MORTAR BED LIFTING OF GRATE
ROLL-FORMED KERB

LIP
SEE NOTE 2.
450 GRATE - 900 x 530
ROADWAY 'RT' KERB PROFILE
LINTEL ON 10mm ROADWAY
MORTAR BED 245 COVER

PIT- DEPTH AS REQUIRED


APPROVED PRECAST OR
CAST IN-SITU PIT DEPTH
Min. 150
230 N12 @ 150CTRS
100mm TYPICAL BOTH WAYS

GRATE DETAIL 3-N16 @ 35CTRS 30 COVER


TYPICAL SUBSOIL 200 200 GRATE DETAIL
DRAIN OUTLET 'SA' KERB
'RT' KERB
SEE NOTE 5
650 NOTE:

450
1. ALL DIMENSIONS ARE IN MILLIMETRES.
SECTION D-D (Min 650mm WIDTH) 2. GRATES TO BE;
- CLASS 'B' FOR OFF ROAD AREAS
- CLASS 'C' - MEDIUM DUTY FOR LIGHT TRAFFIC AREAS
MAY VARY SLIGHTLY
- CLASS 'D' FOR ROADS & COMMERCIAL AREAS
BETWEEN MANUFACTURERS
3. GRATES ARE TO BE HOT DIP GALVANISED 80-85 MICRONS THICK. ALL GRATES TO BE PROVIDED WITH
380 HINGE PINS.
STEP IRON PLACEMENT 4. ALL LINTELS TO BE APPROVED PRECAST TYPE. DIMENSIONS SHOWN ON PLAN TO DENOTE CLEAR
PRECAST LINTEL OPENINGS, MIN SIZE 1.2m. DIMENSIONS MAY VARY BETWEEN MANUFACTURERS.
ROADWAY SEE GRATE DETAIL ABOVE 5. PROVIDE STEP IRONS FOR PITS DEEPER THAN 1.2m.
6. MINIMUM THICKNESS OF WALLS AND BASE TO BE 150mm.
7. ALL PITS TO HAVE A MINIMUM OF SL82 MESH IN BASE AND N12 "L" STARTER BARS (450 LEGS) @ 400 CTRS.
8. PITS BETWEEN 1.5m & 2.5m DEEP TO HAVE SL82 MESH CENTRALLY PLACED IN WALLS FOR FULL DEPTH
150

Min. 200

CAST INSITU PIT DEPTH


WITH N12 "L" CORNER BARS (450 LEGS) @ 400 CTRS.
100mm TYPICAL 9. PITS DEEPER THAN 2.5m OR LONGER THAN 900 OR 1450 WIDE SHALL BE DESIGNED BY A QUALIFIED

AS REQUIRED.
ENGINEER.
TOP OF HIGHEST
CLEARANCE TO

PRECAST PIT

REQUIRED.
DEPTH AS

10. PITS POURED IN MULTIPLE HEIGHT SECTIONS SHALL INCLUDE SL82 MESH OR 400N12 STARTER BARS @
Min. 100

300 c/c.
PIPE

11. COMPRESSIVE STRENGTH (FC) FOR CAST INSITU CONCRETE SHALL BE A MINIMUM 32 MPa @ 28 DAYS.
TYPICAL SUBSOIL 12. NO RENDERING PERMITTED IN STRUCTURAL COMPONENTS.
DRAIN OUTLET 13. THIS STANDARD REFERS TO PITS CONSTRUCTED ADJACENT TO FLEXIBLE PAVEMENTS. TOTAL ISOLATION
SEE NOTE 5 OF PITS IS REQUIRED ADJACENT TO RIGID PAVEMENTS.
14. ALL PITS TO BE ADEQUATELY STREAMLINED AND BENCHED.
* (Max. 1450)
15. FOR PITS LOCATED AT KERB RETURNS REFER TO SD009
SEE NOTE 8
ALL PRECAST PIT CHAMBER
COMPONENTS TO BE STEP IRON NOTE:
SECTION D-D (Max 1450mm WIDTH) APPROVED BY THE 1. STEP IRONS TO COMPLY TO AS1657.
ENGINEER PRIOR TO USE. 2. STEP IRONS TO BE HOT DIPPED GALVANISED OR PLASTIC.
3. STEPS TO BE FIXED INTO THE PIT WALL WITH AN EPOXY RESIN COMPOUND.

maitland city council


infrastructure & works
po box 220, maitland nsw 2320
email: [email protected]
GRATED GULLY PITS WITH
EXTENDED KERB INLETS
MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS
0.01 Rev: 08/04/2019

SD039
SHEET 02 of 02
WARP AREA AS DIRECTED TO
1930 SUIT INCOMING FLOW PATH.
460 1010 460
GRATE OMITTED FOR CLARITY

460
NOTE:
1. ALL DIMENSIONS ARE IN MILLIMETRES.
A A

1025
1945
2. FOR DETAILS OF GULLY GRATING AND FRAME SEE WEDLOCK GRATE CODE
PC9090B OR APPROVED EQUIVALENT. ALL GRATES TO BE PROVIDED WITH - -
LOCKING BOLTS. HINGES TO BE LOCATED ON UPSTREAM SIDE.
3. PROVIDE STEP IRONS FOR PITS DEEPER THAN 1.2m REFER TO SD039.
4. MINIMUM THICKNESS OF WALLS AND BASE TO BE 150mm.

460
5. ALL PITS TO HAVE A MINIMUM OF SL82 MESH IN BASE AND N12 "L" STARTER
BARS (450 LEGS) @ 400 c/c.
6. PITS BETWEEN 1.5m & 2.5m DEEP TO HAVE SL82 MESH CENTRALLY PLACED IN
WALLS FOR FULL DEPTH WITH N12 "L" CORNER BARS (450 LEGS) @ 400 c/c.
7. PITS DEEPER THAN 2.5m OR LONGER THAN 900 OR 1450 WIDE SHALL BE PLAN
DESIGNED BY A QUALIFIED ENGINEER.
8. PITS POURED IN MULTIPLE HEIGHT SECTIONS SHALL INLCUDE SL82 MESH OR
400N12 STARTER BARS @ 300 c/c.
9. COMPRESSIVE STRENGTH (FC) FOR CAST INSITU CONCRETE SHALL BE A
FLUSH OR RAISED
MINIMUM 25 MPa @ 28 DAYS. 55 80 SL72 MESH
GRATE
10. NO RENDERING PERMITTED IN STRUCTURAL COMPONENTS. CENTRAL (TYP)
11. ALL PITS TO BE ADEQUATELY STREAMLINED AND BENCHED.
12. PROVIDE MIN 450mm PINNED TURF SURROUND.
100
13. SHAPE ADJACENT AREAS TO ASSIST WATER COLLECTION.

DEPTH AS REQUIRED
(MIN OD+250)
100 DIA. HOLE FOR SUBSURFACE
DRAIN OUTLET WHERE REQUIRED FLOW
*
900
PIPE DIAM RANGE
600mm TO 750mm INCL
100

1200 825mm TO 900mm INCL 150

150 900 * 150


OUTLET PIPE INVERT
TO MATCH PIT INVERT
SECTION A-A

maitland city council SURFACE INLET PIT Rev: 08/04/2019


infrastructure & works
po box 220, maitland nsw 2320
SD040
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
MORTAR COLLAR 200mm THICK MIN.

500mm WIDE TURFED DEPRESSION

MINIMUM PIT DIMENSIONS


PIT DEPTH <900 900 - 1200 >1200

'Z'
A A
- 'Y' -
`Y' 450 600 600
`Z' 450 600 900

MIN 150Ø PVC OR


APPROVED EQUIVALENT

PLAN
NOTE:
1. INTER-ALLOTMENT DRAINAGE PITS SHALL BE PROVIDED TO THE LOW
CORNER OF EACH LOT UNLESS OTHERWISE PROVIDED.
2. PITS WILL ALSO BE PROVIDED AT CHANGES OF PIPE SIZE, CHANGES IN
GRADE, CHANGED IN PIPE TYPE OR CLASS AND CHANGES IN DIRECTION
OF 45° OR GREATER. SUCH PITS ARE TO BE A MINIMUM INTERNAL SIZE 100mm TURFED DEPRESSION
OF 450 x 450 APPROVED PRECAST OR CAST INSITU.
3. PITS SHALL BE COVERED BY AN APPROVED GRATE TO PROVIDE AN
ADEQUATE SURFACE WATER INLET. ALL GRATES ARE TO BE PROVIDED
WITH EITHER "J" BOLTS OR PINS TO PREVENT REMOVAL. PITS
SURROUNDS WILL BE TURFED AND PEGGED OR NETTED TO A MINIMUM

600
WIDTH OF 500mm.
4. PIT INLET GRATES SHALL BE DEPRESSED 100mm BELOW SURROUNDING
RISER WITH CAP APPROX 600
GROUND LEVEL TO ASSIST SURFACE WATER COLLECTION.
BELOW SURFACE WITH BLUE
5. PROVIDE STEP IRONS FOR PITS DEEPER THAN 1.2m. REFER TO SD039.
STORMWATER TAPE TO PEG
SUCH PITS ARE TO HAVE A MINIMUM INTERNAL SIZE OF 900 x 600mm.
6. CONNECTION FOR ROOF WATER FOR SINGLE RESIDENTIAL DWELLINGS
ON SURFACE
SHALL BE PROVIDED VIA A 150mm DIA. STUB INTO THE SIDE OF THE PIT.
7. PIPE CONNECTION TO PIT TO BE SEALED WITH MINIMUM 100mm MORTAR
COLLAR FOR SEAL AND SUPPORT.

CONCRETE COLLAR
3m LENGTH OF SOCKED SUBSOIL
SECTION A-A DRAINAGE PIPE ON UPSTREAM SIDE OF
EVERY 2ND PIT IN THE IAD PIPELINE

maitland city council INTER ALLOTMENT DRAINAGE PIT Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD043
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
IAMETER
IPE D
TYPICAL AREA FOR PROTECTIVE
MEASURES (3) INCLUDING
4xP TYPICAL AREA FOR PROTECTIVE
UNSEALED SHOULDERS MEASURES (3) INCLUDING
UNSEALED SHOULDERS

EXTEND MATTRESS UP BATTER


TO MINIMUM HALF HEIGHT OF
CULVERT OPENING ROCK FILLED MATTRESS
ON GEOTEXTILE FABRIC NOTE:
1. SAFETY FENCING SHALL BE PROVIDED
ABOVE HEADWALL SUBJECT TO
PROXIMITY OF PEDESTRIANS.
2. ENERGY DISSIPATERS SHALL BE
INCLUDED IN THE DESIGN AS REQUIRED
3. WHERE THERE IS A POSSIBILITY OF
OVERFLOW OF THE ROAD, SCOUR
PROTECTION MEASURES ARE TO BE
IMPLEMENTED ON SHOULDERS AND
BATTERS

maitland city council HEADWALL SCOUR PROTECTION Rev: 08/04/2019


infrastructure & works
po box 220, maitland nsw 2320
TYPICAL TREATMENT SD045
email: [email protected] SHEET 01 of 01

MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS


'SA' KERB & GUTTER WITH DRAINAGE BREAKOUTS

SURFACE INLET PIT SD040

'SOCKED SUBSOIL DRAINAGE PIPE

NOTE
FLUSH POINTS TO BE PROVIDED IN THE
SUB-SOIL DRAIN AT UPSTREAM ENDS &
EVERY 60.0m

PLAN - SWALE DRAIN PROVIDE ROCK PROTECTION


AT BREAKOUTS
900 TYP.
PLANTING SOIL 100mm MIN. 'SA' KERB & GUTTER WITH
PREFERRED SLOPE 6:1 DRAINAGE BREAKOUTS
(MAX. 4:1)
800

CLEAN GRADED FILTER SAND


OR 10mm AGGREGATE

'SOCKED SUBSOIL DRAINAGE PIPE

300

TYPICAL SECTION - SWALE DRAIN

maitland city council DRAINAGE SWALE Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD046
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
TYPICAL VEGETATED FILTER STRIP
PLANT COVER
SIDE SLOPES 1:6 MAX. PIT GRATE
PONDED WATER 150 MAX.
FALL

100 Min. BIORETENTION DEPTH


PAVEMENT

GEOFABRIC LINER

FILTER MATERIAL
TO STORMWATER SYSTEM
(SANDY LOAM)

TRANSITION FILTER
(BEACH SAND)
200 Min.

CRUSHED ROCK 4-7mm


REINFORCED CONCRETE OVERFLOW INLET PIT
BIORETENTION AREA 100-150 DIA. PERFORATED
UNDERDRAINAGE PIPE
(50 Min. COVER)

NOTE: · SURFACE AREA AND DIMENSIONS OF SYSTEM


1 ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED OTHERWISE · FILTER AREA AND DEPTH
2. THE BIORETENTION SYSTEM SHALL BE DESIGNED BY A SUITABLY QUALIFIED · UNDERDRAINAGE PIPE SIZE
ENVIRONMENTAL ENGINEER TAKING INTO ACCOUNT THE FOLLOWING: · TRANSITION SAND LAYER
· TREATABLE VOLUME · BACK FLUSH FOR UNDERDRAINAGE PIPES
· TREATABLE FLOW RATE · HIGH FLOW BYPASS
· MAXIMUM PONDED DEPTH (150mm) · LOW PERMEABILITY LINER (IF REQUIRED)
· MAXIMUM SIDE SLOPES (1:6) 3. THE BIORETENTION SYSTEM SHALL NOT BE USED FOR SEDIMENT CONTROL DURING
· FILTER MEDIA HYDRAULIC PERMEABILITY CONSTRUCTION.
· PLANT SPECIES 4. PITS AND GRATES IN ACCORDANCE WITH COUNCIL STANDARDS.

maitland city council BIORETENTION SYSTEM (PLANTING BED) Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD047
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
NOTE:
1. ANY TREES SURROUNDING WETLAND
SHOULD BE DISTANCED TO ALLOW ACCESS
BY MAINTENANCE PLANR IN AND AROUND
WETLAND.
2. ALL WEATHER ACCESS IS REQUIRED TO
WETLAND.

EPHEMERAL ZONE:
ABOVE WATER AND SHALLOW MARSH: MARSH: DEEP MARSH: PERMANENTLY WET:
AROUND WETLAND 0-200mm 200-350mm 350-500mm 350-1000mm

EPHEMERAL ZONE (ABOVE WATER SHALLOW MARSH (0 - 200mm): DEEP MARSH (350 - 500mm):
LEVEL AND AROUND WETLAND): · Baumea articulata Jointed Twig-rush · Baumea articulata Jointed Twig-rush
· Eucalyptus camaldulensis Red River Gum · Bolboschoenus caldwellii Club-rush · Bolboschoenus caldwellii Club-rush
· Tristaniopsis laurina Water Gum · Bolboschoenus fluviatilis Stream Club-sedge · Eleocharis acuta Spike-rush
· Callistemon salignus Willow Bottlebrush · Eleocharis acuta Spike-rush · Juncus usitatus Common-rush
· Banksia integrifolia Coast Banksia · Juncus usitatus Common-rush · Schoenoplectus validus River Club-rush
· Casuarina glauca Swamp Oak · Schoenoplectus validus River Club-rush · Triglochin procerum Water Ribbons
· Syzygium paniculatum Magenta Lilly Pilly · Vallisneria gigantea Ribbonweed
· Melaleuca quinquenervia Broad-leaved MARSH (200 - 350mm):
Paperbark · Lepironia articulata PERMANENTLY WET (350 - 1000mm):
· Melaleuca styphelioides Black Tea Tree · Eleocharis acuta Spike-rush · Bolboschoenus caldwellii Club-rush
· Carex inversa Knob Sedge · Ceratophyllum demersum Hornwort
· Ranunculus inundatus Buttercup
· Triglochin procerum Water Ribbons
· Vallisneria gigantea Ribbonweed

maitland city council WETLAND SPECIES LIST Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD048
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
2 x 1800mm x 50mm HARDWOOD STAKES
APPROVED TREE SPECIES PLACED OUTSIDE OF ROOTBALL

50mm WIDE JUTE WEBBING TIED


IN A FIGURE EIGHT PATTERN
AND STAPLED TO STAKES.

MULCH WITH HARDWOOD CHIP

1100
75mm DEEP, 1m2. REDUCE DEPTH
OF MULCH AT PLANT BASE.

BACKFILL WITH (19-35mm)


GRAVEL OR CRUSHED ROCK.

600
ROOT DIRECTOR BOX (RD640 / RD1050)
ARBORGREEN LANDSCAPE PRODUCTS
OR EQUIVALENT
TURF

75
200 - 300
EXISTING KERB

NOTE:
1. ALL DIMENSIONS ARE IN MILLIMETRES.
2. REFER TO SD001 FOR FOOTWAY ALLOCATIONS PRIOR

700
TO EXCAVATION WORKS.
3. PLACE HARDWOOD STAKES PARALLEL TO KERB.

150
FERTILIZE WITH 4 x 21gm SLOW
RELEASE TABLETS EQUAL TO
'AGRIFORM' 20 : 4.3 : 4.1

1200
EXCAVATE HOLE 150mm DEEPER THAN
REQUIRED FOR PIT, AS SHOWN.
CULTIVATE GYPSUM 50gm/m2 TO BASE
TYPICAL SECTION

maitland city council STREET TREE PLANTING Rev: 22/07/2019


infrastructure & works
po box 220, maitland nsw 2320
TYPICAL TREATMENT SD049
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
LOCKED RAISED GRATE WITH LARGE
OPENINGS (SIMILAR TO RMS "MEDIAN PIT")

CONTROLLED OUTLET AT WEIR OUTLETS, AS REQUIRED,


PERMANENT WATER LEVEL TO CONTROL FLOWS

100YR WATER LEVEL SPILLWAY


20YR WATER LEVEL
3.0m
5:1 Preferred PERMANENT WATER LEVEL
4:1 Max 200mm
See Chapter 6
1
MACROPHYTE BENCH 6

DEEP WATER ZONE


OR SILT TRAP GATE VALVE ANTI-SEEP COLLAR

ADJUSTABLE WALL HEIGHT OUTLET TO DRAIN PERMANENT WATER


(SUCH AS TIMBER SLEEPERS)

TYPICAL ARRANGEMENT

maitland city council CONSTRUCTED WETLAND (with Detention) Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD050
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
HINGED & LOCKABLE HINGED & LOCKABLE
SURFACE INLET GRATE SURFACE INLET GRATE
UPVC OVERFLOW
PIPE (GENERALLY
150mm)

REMOVABLE LYSAGHT RH3030


100mm UPVC VENT MAXI-MESH SCREEN OR EQUIVALENT 100mm UPVC VENT

Min. 600 DEEP

Min. 600 DEEP


DETENTION DETENTION BRACING ROD
BRACING ROD TO TANK TO SUPPORT OUTLET PIPE
TANK
SUPPORT SCREEN SCREEN (DIAMETER TO
MATCH THAT OF
OVERFLOW PIPE)

150mm UPVC 150mm UPVC


90mm OUTLET PIPE

REDUCER (90-150)

REDUCER TO SUIT
CONTROL PIPE
COMPACTED GRANULAR BASE WEEPHOLES COMPACTED GRANULAR BASE (40-50-65-75-90)
WEEPHOLES

WITHOUT OVERFLOW PIPE WITH OVERFLOW PIPE


(WHERE SURFACE OVERFLOW AVAILABLE) NOTE:
1. ALL DIMENSIONS ARE IN MILLIMETRES
2. STORMWATER PIPES TO BE SEWER GRADE ACROSS PUBLIC FOOTWAY.
3. CONCRETE COMPRESSIVE STRENGTH 32MPa.
SIDE WALLS OF ALL PITS DEEPER THAN 1500 ARE TO BE REINFORCED WITH ONE
LAYER OF SL82 MESH RETURNED 300 INTO BASE. WHERE REQUIRED INCREASE
CONCRETE STRENGTH TO 32MPa.
4. DEPTH OF PIT NOT TO EXCEED 2000mm.
5. PROVIDE STEP IRONS FOR PITS DEEPER THAN 1200mm REFER TO SD039.
6. ALL EXPOSED EDGES TO BE ROUNDED WITH 20mm RADIUS

maitland city council ON-SITE STORMWATER DETENTION PIT Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD052
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 03
NOTE:
DOWNPIPE CONNECTION TO 1. REFER TO SD052-3 FOR LOCATION OF DISPOSAL TRENCH.
ROOF GUTTER
TANK VIA SCREENED INLET 2. INSTALL FIRST FLUSH DEVICE TO SATISFY THE BUILDING
CODE OF AUSTRALIA & TO ENSURE MINIMUM "HEAD" IS

HEAD (Min. 500)


MAINTAINED.
RAINWATER TANK(S)
CAPACITY AS REQUIRED

OVERFLOW

1500l. OF ADDITIONAL DETENTION VOLUME

DETENTION SPACE
OVERFLOW PIPE 150Ø MIN
DOWN PIPE (ALTERNATIVELY 2x100Ø)

19mm BLEED OFF CONNECTION


REQUIRED BASIX VOLUME

TO OVERFLOW PIPE.
OPERATING RE-USE WATER

OPERATIONAL WATER LEVEL (MAINS TOP UP)


HOUSE SUPPLY
PERMANENT WATER

LOCKED GRATE OVERFLOW PIPE & SUBSOIL


PUMP SUPPORT PAD PIPE TO DRAINAGE SYSTEM.
(SEE SD052-3)

4.5m (MIN) DISPOSAL

.
300MIN TRENCH (SEE SD052-3)
100mmØ CLEANOUT PIPE SILT TRAP
CONNECTED FROM LOW POINT SCREW CAP WITH 6mm
OF DOWN PIPE TO PIT HOLE AT BASE OF CAP
PROPRIETARY PIT

maitland city council ON-SITE STORMWATER DETENTION Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
TANK & DISPOSAL TRENCH SD052
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 02 of 03
TO INTER-ALLOTMENT DRAIN, CHANNEL,

150 MIN.
PIPE OR STREET GUTTER ONLY OPTIONAL
DEPRESSION
STORAGE
REMOVABLE 'LYSAGHT'S' RH3030 GEOTEXTILE FILTER FABRIC
LOCKABLE GRATE MAXIMESH SCREEN OR EQUIVALENT SANDY LOAM SOIL/TURF

50
END CAP

650

350
50 'TUNNEL TRENCH' OR APPROVED EQUIVALENT
LEVEL

. 300 MIN. 'STONE DRAINAGE' FILTER MATERIAL 150 535 150

100
SILT TRAP
835
3.0m MIN. PER 100sq/m OF CATCHMENT AREA (ROOF & PAVING)

SECTION B-B
WEEPHOLES IN BASE OF PIT
SECTION A-A SOCKED SUBSOIL DRAIN WHERE
B REQUIRED REFER TO NOTE 1
SOCKED SUBSOIL DRAIN WHERE -
DROP DOWN
REQUIRED. REFER TO NOTE 1.
NOTE:
1. IN CLEAN SAND CONDITIONS, TRENCHING SHALL BE A MIN OF 1.Om
CLEAR OF STRUCTURAL FOUNDATIONS AND PROPERTY BOUNDARIES

2. IN CLAY CONDITIONS, TRENCHING SHALL BE A MIN. OF 3.0m CLEAR OF


600
STRUCTURAL FOUNDATIONS WITH A SOCKED SUBSOIL DRAIN
INSTALLED
A A
'TUNNEL TRENCH' OR APPROVED EQUIVALENT
- - 3. REFER TO AUSTRALIAN RUNOFF QUALITY SECTION 11.
MIN. 3 x 90Ø PIPE OUTLETS
4. THE TRENCHING SHALL BE PLACED LEVEL, WHERE POSSIBLE &
ALONG THE CONTOUR OF THE LAND. DEPTH MAY BE VARIED TO SUIT.

5. THE TRENCHING SHALL BE PLACED DOWNHILL OF BUILDINGS AND TO


ACHIEVE MAXIMUM AREA, SLOPING AWAY FROM THE TRENCH, FOR
WEEPHOLES IN BASE OF PIT PLAN DISPERSAL OF WATER.
450 x 450 DEBRIS TRAP PIT B
INLET PIPES AS REQUIRED - 6. THE DISPERSAL AREA SHOULD BE CHOSEN TO AVOID OVERFLOW
TOWARD A BUILDING OR ONTO ADJOINING PROPERTIES.

maitland city council ONSITE STORMWATER DISPOSAL TRENCH Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD052
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 03 of 03
2400
ARC ACACIA GALVANISED FENCE PANELS
2400mm LONG x 920mm HIGH
50mm SQUARE RHS POST
2.5mm WALL THICKNESS
SECURE WITH 'U' CLIPS AND
WELD NUT TO THE TOP AND
1000

BOTTOM OF POSTS

PLAYERS SIDE
FIXING DETAIL
1620

SPECTATORS
(NOT TO SCALE)

SIDE
600
MOWING STRIP 100mm
25-75mm DEEP X 350mm WIDE
GROUND NOTE
CLEARANCE 1. ALL DIMENSIONS ARE IN MILLIMETRES
100 100
AT CENTRE OF MASS CONCRETE FOOTING 300mm Ø 2. 20MPa CONCRETE
300Ø PANEL 3. INSTALL CONTROL JOINT AT EACH POST
300Ø
4. INSTALL EXPANSION JOINT AT EVERY 6th POST

WELDMESH FENCE
(NOT TO SCALE)
FIX WITH THIMBLE & 3 x WIRE GRIPS TO SUIT CABLE
BURR THREADS OF GRIPS TO PREVENT REMOVAL
2500 2500
20mm Ø GALVANISED STEEL TACK WELD GALV. STEEL CAP TO POSTS EYE BOLT TO SUIT CABLE
CABLE THREADED THROUGH POST WELD TO POST

END OR GATE POST


DN90H GALV. PIPE 1500 LONG
DRILL 30Ø HOLE
150

100

6
300
1200

6
400

500

300

400

700
1500
MOWING STRIP 100mm
NOTE 300Ø
DEEP X 350mm WIDE INTERMEDIATE POST
1. FOOTING CONCRETE TO BE 20MPa.
2. ALL WELDS ARE TO BE DEBURRED, DN90H GALV. PIPE 1200 LONG WITH CAP
CLEANED & PROTECTED WITH
COLD GALVANISED PAINT. POST & CABLE FENCE
(NOT TO SCALE)

maitland city council FENCING Rev: 01/07/15


infrastructure & works
po box 220, maitland nsw 2320
SD057
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 01
Hinge pin & washer assy.
Tack weld washer to hinge
plate after assembly Hinge post assembly
Lock post
Upper post end plate
Top hinge plate

100x100x5 SHS Top rail PLAN - GENERAL ASSEMBLY

4 660

Hinge Post
100x100x5 SHS Gate
Hinge post

Gate end post Gate

Lock Post
1 000

1 000
4 060

Hinge pin

Bottom rail

Lower post end plate


ELEVATION
GENERAL ASSEMBLY
Hinge plate
12Ø Pins 350 long
Web plate with pin

900 600 600


HINGE ASSEMBLY DETAIL

NOTE LOCK POST


1. All dimensions are in millimetres
2. All welds to be 6mm continuous fillet
3. Gate & posts to be hot dipped galvanised after fabrication
4. All field welds to be cold galvanised
5. All concrete to be 20MPa

maitland city council STANDARD ACCESS GATE Rev: 22/07/2019


infrastructure & works
po box 220, maitland nsw 2320
GENERAL ARRANGEMENT SD058
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 01 of 02
Post end plate 4 056 5P
Press fit to inside of
Lock tongue
Hinge Post 80
21Ø 65
100x100x5 SHS Top Rail 4100 Long
20PL 1825 20PL
800 425

645

R2
50
Bottom Rail & Strut

5
Ø1

30
100x100x5 SHS End Post 50NB Pipe Heavy Grade
10

LOCK TONGUE
Bottom Rail
POST END PLATE
Post end plate
ELEVATION - GATE NOTE
300 Top hinge plate 1. All dimensions are in millimetres
Lock Box
2. All welds to be 6mm continuous fillet
645 3. Gate & posts to be hot dipped galvanised after fabrication Cap Plate
10

300 85 4. All field welds to be cold galvanised 5PL


5. All concrete to be 20MPa
21Ø 110
40
745

120
20PL
825

Cap Plate
5PL

10 TOP HINGE PLATE


150x150x5 SHS

1950
155

21
Lower hinge assy. Plan
2100

A A
150

120
100x100x5 -
20PL 60 - = =

70
SHS

5PL
80
85
15
20

Ø
20

40
30
Ø

10PL
110

75 LOCK BOX
10

100x100x5 SHS Washer required for top pin only. Weld to pin.
10 Field weld washer to hinge plate after gate
110 assembly
HINGE POST SECTION A-A HINGE PIN See Sheet 58/1 for 2 x 100x100x5 SHS
LOWER HINGE ASSEMBLY hinge assembly detail Stitch welded together
LOCK POST

maitland city council STANDARD ACCESS GATE Rev: 22/07/2019


infrastructure & works
po box 220, maitland nsw 2320
COMPONENTS SD058
email: [email protected] MANUAL OF ENGINEERING STANDARDS - STANDARD DRAWINGS SHEET 02 of 02