Rev.4 del 01/2011 O.M.A.C. s.r.l.

Operation and Maintenance


B Series
Lobe Positive Displacement
Group Pump Unit

Translation from the Original Instructions

O.M.M. B SERIES rev.4 01/2011 All rights reserved


O.M.A.C. s.r.l.
O.M.A.C. S.R.L.
1 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
RUBIERA (RE) - ITALY
Rev.4 del 01/2011 O.M.A.C. s.r.l.

© Copyright by
O.M.A.C. s.r.l.
Via Giovanni Falcone, 8
42048 RUBIERA (RE) – ITALY
Printed directly by the company
Revision 4 - January 2010

O.M.A.C. s.r.l.
II Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

SUMMARY
INTENDED USE VII
EC DECLARATION OF CONFORMITY (EXAMPLE) IX
HOW TO CONSULT AND KEEP THIS DOCUMENTATION X
SYMBOLS USED X
KEEPING THE MANUAL XI
LABLES APPLIED XI
TERMS AND DEFINITIONS XII

CHAPTER 1: MACHINE AND PUMPED FLUID SPECIFICATIONS Chap.1-pag.1


1.1 Envisioned duration Chap.1-pag.1
1.2 Technical description of the machine Chap.1-pag.1
1.2.1 Operation principle of the B Series LDPU Chap.1-pag.1
1.2.2 B Series LDPU coding Chap.1-pag.2
1.3 Technical features Chap.1-pag.4
1.3.1 Technical features of the B Series LDPU Chap.1-pag.5
1.3.2 Variation of maximum operating pressure according to the temperature Chap.1-pag.5
1.3.3 Motorization and transmission coupling technical features Chap.1-pag.6
1.3.4 Rotor clearances Chap.1-pag.6
1.3.5 Rotor geometry Chap.1-pag.6
1.3.6 Tightening torque Chap.1-pag.7
1.3.7 Mechanical seal overall dimensions Chap.1-pag.7
1.3.8 Weights and dimensions table of the B Series LDPU Chap.1-pag.8
1.3.9 Dimensions of pumping bodies couplings, equipped with heating/cooling chamber and seals flushing Chap.1-pag.10
1.3.10 Suction inlet dimensions in “widened rectangular inlet” version of the B Series LDPU Chap.1-pag.10
1.3.11 Bearings Chap.1-pag.11
1.3.12 Lubricants used and quantities Chap.1-pag.11
1.4 Intended use Chap.1-pag.11
1.4.1 Recommended use guidelines for the transfer of the some types of processed fluid Chap.1-pag.12
1.5 Material specifications Chap.1-pag.14
1.6 Occupied workplaces Chap.1-pag.14
1.7 Indication of the safety systems Chap.1-pag.14
1.7.1 Flexible coupling protection Chap.1-pag.15
1.7.2 Emergency stop Chap.1-pag.15
1.7.3 Seals protections Chap.1-pag.15
1.7.4 Optional features: full fairing Chap.1-pag.15
1.7.5 Optional features: electric safety devices and pressure limiters Chap.1-pag.15
1.8 Noise and vibrations emitted Chap.1-pag.16
1.9 Use of the personal protection equipment Chap.1-pag.16
1.10 Personnel training Chap.1-pag.16
1.11 B Series LDPU optional features Chap.1-pag.16
1.11.1 Pump unit in aseptic version Chap.1-pag.16
1.11.2 Pump unit with widened rectangular inlet Chap.1-pag.17
1.11.3 Pump unit with heating / cooling chamber and front cover Chap.1-pag.17
1.11.4 Pump unit with mechanical safety valve on cover Chap.1-pag.17
1.11.5 Pump unit with pneumatic safety valve on cover Chap.1-pag.18
1.11.6 Pump unit with external mechanical bridge safety valve Chap.1-pag.18
1.12 LDPU optional features Chap.1-pag.18
1.12.1 Motorized B Series LDPU on fixed base Chap.1-pag.18
1.12.2 Motorized B Series LDPU on trolley base Chap.1-pag.18

CHAPTER 2: TRANSPORTATION OF THE B SERIES LDPU Chap.2-pag.1


2.1 Hoisting and transportation Chap.2-pag.1
2.2 Delivery and unpacking Chap.2-pag.2
2.3 Conditions for storage or extended interruptions of service Chap.2-pag.2
2.4 Packaging composition for future handling Chap.2-pag.3
2.5 Handling the LDPU without packaging Chap.2-pag.3

CHAPTER 3: INSTALLATION OF THE B SERIES LDPU Chap.3-pag.1


3.1 Destination and intended environments Chap.3-pag.1
3.2 Environmental conditions Chap.3-pag.1
3.2.1 Room lighting Chap.3-pag.1
3.3 Installation and assembly Chap.3-pag.1
3.3.1 Notes for the installer Chap.3-pag.2
3.3.2 Preliminary checks Chap.3-pag.2
3.3.3 Installation Chap.3-pag.2
3.3.4 Accessories fitting Chap.3-pag.5
3.4 Cleaning and Hygiene of the LDPU Chap.3-pag.9
3.4.1 LDPU for alimentary use Chap.3-pag.9
3.4.1.1 External cleaning instructions Chap.3-pag.10
3.4.1.2 Internal cleaning instructions Chap.3-pag.10

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 III
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

SUMMARY

3.4.1.2.1 Internal cleaning :CIP (Cleaning In Place) / SIP (Sterilising In Place) Chap.3-pag.10
3.4.1.2.2 Internal cleaning: manual cleaning Chap.3-pag.11
3.4.2 LDPU for chemical use Chap.3-pag.12
3.4.2.1 External cleaning instructions Chap.3-pag.12
3.4.2.2 Internal cleaning instructions Chap.3-pag.12
3.4.2.2.1 Internal cleaning: CIP (Cleaning In Place) Chap.3-pag.13
3.4.2.2.2 Internal cleaning: manual cleaning Chap.3-pag.13
3.5 Connection to energy sources Chap.3-pag.14
3.5.1 Connection to electrical system Chap.3-pag.14
3.5.2 Connection to the hydraulic system Chap.3-pag.14
3.5.3 Connection to the pneumatic system Chap.3-pag.15
3.6 Use of lubricants Chap.3-pag.16
3.7 Installation and pre-start check: operation test Chap.3-pag.16

CHAPTER 4: USE OF THE B SERIES LDPU Chap.4-pag.1


4.1 Inteded use Chap.4-pag.1
4.2 Controls Chap.4-pag.2
4.3 LDPU volumetric capacity adjustment methods Chap.4-pag.3
4.3.1 Adjustment of the volumetric capacity with the inverter Chap.4-pag.3
4.3.2 Adjustment of the volumetric capacity via mechanical speed controller Chap.4-pag.3
4.4 Work cycle description Chap.4-pag.4
4.5 Cycle start instructions Chap.4-pag.4
4.5.1 Preliminary operations: check list Chap.4-pag.4
4.5.2 First start-up Chap.4-pag.5
4.6 Stopping instructions Chap.4-pag.5
4.7 Instructions for restarting after a stop Chap.4-pag.5
4.8 Switch-off Chap.4-pag.5
4.9 Emptying Chap.4-pag.5
4.10 Residual risks Chap.4-pag.6
4.11 Dangers generated by use Chap.4-pag.6
4.12 Prohibited use Chap.4-pag.6
4.13 Management of emergency situations Chap.4-pag.6

CHAPTER 5: MAINTENANCE OF THE B SERIES LDPU Chap.5-pag.1


5.1 Troubleshooting and solving problems Chap.5-pag.1
5.2 Instruction for carrying out checks Chap.5-pag.4
5.2.1 Daily checks Chap.5-pag.5
5.2.2 Weekly checks Chap.5-pag.5
5.2.3 Six monthly checks Chap.5-pag.5
5.3 Periodic check of the safety and emergency devices Chap.5-pag.5
5.4 Indication of dangerous temperatures Chap.5-pag.5
5.5 Oils present Chap.5-pag.5
5.6 Test and checks Chap.5-pag.5
5.6.1 Electrical checks Chap.5-pag.5
5.6.2 Single mechanical seals Chap.5-pag.5
5.6.3 Mechanical seals with flushing Chap.5-pag.6
5.6.4 Mechanical seals balancing Chap.5-pag.6
5.6.5 Packing seals Chap.5-pag.6
5.7 Disassembly and assembly operations of B100 size pump Chap.5-pag.7
5.7.1 Disassembly of the pumping body Chap.5-pag.8
5.7.2 Assembly of the pumping body Chap.5-pag.8
5.7.3 Disassembly of the bearings box Chap.5-pag.9
5.7.4 Assembly of the bearings box Chap.5-pag.9
5.7.5 Disassembly of the lip seals Chap.5-pag.10
5.7.6 Assembly of the lip seals Chap.5-pag.10
5.8 Disassembly and assembly operations of B1 B2 B3 B4 B470 B490 size pump Chap.5-pag.11
5.8.1 Disassembly of the pumping body Chap.5-pag.13
5.8.2 Assembly of the pumping body Chap.5-pag.13
5.8.3 Disassembly of the bearings box Chap.5-pag.13
5.8.4 Assembly of the bearings box Chap.5-pag.14
5.9 Disassembly and assembly operations of B550 B660 B680 size pump Chap.5-pag.16
5.9.1 Disassembly of the pumping body Chap.5-pag.18
5.9.2 Assembly of the pumping body Chap.5-pag.18
5.9.3 Disassembly of the bearings box Chap.5-pag.19
5.9.4 Assembly of the bearings box Chap.5-pag.19
5.10 Post maintenance check Chap.5-pag.20

CHAPTER 6: DECOMMISSIONING OF THE B SERIES LDPU Chap.6-pag.1


6.1 Disconnection from energy sources Chap.6-pag.1

O.M.A.C. s.r.l.
IV Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

SUMMARY

6.2 Disassembly Chap.6-pag.2


6.3 Storage after its use Chap.6-pag.2
6.4 Demolition and disposal Chap.6-pag.2

CHAPTER 7: SPARE PARTS OF THE B SERIES LDPU Chap.7-pag.1


7.1 List of spare parts and section drawings of the lobe displacement pump Chap.7-pag.1
7.1.1 B100: Spare parts list Chap.7-pag.2
7.1.1.1 Pump exploded view drawing Chap.7-pag.2
7.1.1.2 Spare parts names and codes Chap.7-pag.3
7.1.1.3 Seals section drawings Chap.7-pag.4
7.1.1.4 Gasket o-ring codes for mechanical seals Chap.7-pag.4
7.1.2 B105 B110 B115: Spare parts list Chap.7-pag.5
7.1.2.1 Pump exploded view drawing Chap.7-pag.5
7.1.2.2 Spare parts names and codes Chap.7-pag.6
7.1.2.3 Seals section drawings Chap.7-pag.8
7.1.2.4 Gasket o-ring codes for mechanical seals Chap.7-pag.9
7.1.2.5 Balancing ring codes for single and flushed mechanical seals Chap.7-pag.10
7.1.2.6 Single and double mechanical seals codes Chap.7-pag.10
7.1.3 B215 B220 B325 B330 B390 B430 B440 B470 B490: Spare parts list Chap.7-pag.11
7.1.3.1 Pump exploded view drawing Chap.7-pag.11
7.1.3.2 Spare parts names and codes Chap.7-pag.12
7.1.3.3 Seals section drawings Chap.7-pag.16
7.1.3.4 Gasket o-ring codes for mechanical seals Chap.7-pag.18
7.1.3.5 Balancing ring codes for single and flushed mechanical seals Chap.7-pag.18
7.1.3.6 Single and double mechanical seals codes Chap.7-pag.19
7.1.4 B550 B660 B680: Spare parts list Chap.7-pag.20
7.1.4.1 Pump exploded view drawing Chap.7-pag.20
7.1.4.2 Spare parts names and codes Chap.7-pag.22
7.1.4.3 Seals section drawings Chap.7-pag.24
7.1.4.4 Gasket o-ring codes for mechanical seals Chap.7-pag.27
7.1.4.5 Balancing ring codes for single and flushed mechanical seals Chap.7-pag.27
7.1.4.6 Single and double mechanical seals codes Chap.7-pag.28
7.1.5 Name and codes of pumping bodies Chap.7-pag.29
7.1.6 Codes of the springs used in the mechanical safety valve Chap.7-pag.30
7.1.7 Codes of the springs used in the external bridge mechanical safety valve Chap.7-pag.30
7.2 Recommended spare parts Chap.7-pag.30
7.3 How to order spare parts Chap.7-pag.30

CHAPTER 8: ASSISTANCE Chap.8-pag.1

CHAPTER 9: WARRANTY OF THE B SERIES LDPU Chap.9-pag.1

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 V
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

O.M.A.C. s.r.l.
VI Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

INTENDED USE
The “B Series Lobe Positive Displacement Pump Unit”, manufactured and marketed by O.M.A.C. s.r.l., which in this documentation will be indicated with
the abbreviation LDPU, has been designed and made to be assembled in industrial plants owned by third parties, to transfer volumes of fluid, compatible
with the materials used during the construction of this machine: section 1.4.1 lists the recommended operational features of the LDPU, depending on
the fluid.
The LDPU requires compliance with all technical indications in this use and maintenance manual, which in this documentation will be indicated with the
abbreviation OMM, for its proper installation.
In general, the fluid must meet the following specifications:
Fluid properties and range of use:

1) TEMPERATURE: from -35°C to +180°C


2) VISCOSITY: Maximum 200’000cPs with forced feeding
3) HARD PARTICLE SIZE: Maximum 80% of clearance between rotors (see sect.1.3.4)

The LDPU has been designed and made for two types of use:
• alimentary use;
• chemical use.

WARNING:
The LDPU, for alimentary use, has been made to ensure a hygienic standard equal to LEVEL 1, on the basis of UNI EN 13951.

The LDPU for alimentary use and for chemical use has been designed to transfer volumes of fluid without altering the organoleptic properties not the
physical properties.

WARNING:
During its normal use, the LDPU for alimentary use and chemical use does not alter the organoleptic characteristics not the physical characteristics of
the fluid.

Every LDPU comes with a technical sheet indicating the operational features in relation to the fluid that must be handled (name of the fluid, viscosity
range, capacity range, speed range, temperature range), as declared at the time of purchase by the Customer.
Section 1.3 shows a facsimile of the LDPU technical sheet.
Every modification to what is indicated in the specific technical sheet or variation of the machine operating parameters must be authorised in writing by
O.M.A.C. s.r.l.; the absence of such authorisation is deemed “improper use” and will void any warranty or liability under way between Manufacturer and
Customer.

DANGER:
Any use of the LDPU in conditions other than those indicated in “Fluid properties and range of use” and in conditions other than those indicated in the
machine technical sheet is forbidden, without explicit written authorisation, issued by O.M.A.C. s.r.l.

The LDPU for alimentary use and for chemical use has NOT been designed nor built to handle pharmaceutical, explosive, etc. fluids, and in general
fluids that do not comply with the indications of the specific technical sheet. In addition, the LDPU for alimentary use and chemical use has NOT been
designed nor built to handle what is indicated in Regulation (EC) No. 1005/2009 of the European Parliament and the Council of 16 September, 2009, on
substances that deplete the ozone layer.

ATTENTION:
It is forbidden to use the LDPU for alimentary use and chemical use to transfer the substances listed in Annex I of Regulation No. 1005/2009.

The pumping part of the LDPU is made up of the rotorcase, in which two rotors are housed (sect. 1.3.5 lists the types of rotors used), which rotate
synchronised in the opposite direction to each other.
The rotorcase receives the process fluid from the suction inlet, originating from the plant of the Customer. During the operation of the LDPU, the
cavities between the lobes of the rotors are filled with fluid and the counter-rotation of the rotors transfers the fluid to the delivery outlet of the rotorcase,
channelling it in the plant where the LDPU is installed.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 VII
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

O.M.A.C. s.r.l.
VIII Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

(Declaration of conformity to be attached)

EC DECLARATION OF CONFORMITY
EC Declaration of conformity
(Machinery Directive 2006/42/EC)

We, O.M.A.C. s.r.l., with registered office in Via Falcone n.8 - 42048 Rubiera (RE) – Italy, Tel. 0522/629371 - Fax. 0522/628980
E-mail: [email protected] Website: www.omacpompe.com

hereby declare under our exclusive responsibility that:

Mrs Paola Zavaroni, Via Falcone, 8 - 42048 Rubiera (RE) Italy, is authorised to establish and
keep the technical documentation relative to the machine called

“MOTORIZED B SERIES LOBE POSITIVE DISPLACEMENT PUMP UNIT”


or “MOTORIZED B SERIES LOBE POSITIVE DISPLACEMENT PUMP UNIT WITH ELECTRIC PANEL”
or “B SERIES LOBE POSITIVE DISPLACEMENT PUMP UNIT complete with “TRANSMISSION DEVICE”

Model:________________________ Serial No: ____________________________ Specifications: _______________________

Date of issue:___________________

designed and built for pumping, in a third party plant, a medium (alimentary fluid /
chemical fluid) to which this declaration refers to.

The machine is compliant with the safety requirements provided by Directive 2006/42/EC

with Regulation EC No.1935/2004

and with Directives: 2006/95/EC – 2004/108/EC – 94/9/EC


and in accordance with the provisions of the following harmonised standards:

* * * REFERENCE STANDARDS* * *

This machine is equipped with:

Gear Unit/Speed Controller/Gear motor:________________ Supplier:___________________Specifications:__________________________________


Electric motor/Hydraulic motor:_______________________ Supplier:___________________Specifications:__________________________________
Flexible transmission coupling:_______________________ Supplier: ___________________

NOTE: any modifications to the machine, to which this declaration refers to, to the processing fluid and conditions of use of the process fluid, specified in
the relative technical sheet, will make this declaration null and void. O.M.A.C. s.r.l. does not assume any liability arising from the incompatibility between
the process fluid and materials which make up the machine, subject of this declaration, if the customer does not specify the particulars of the process
fluid and its physical characteristics.

RUBIERA (RE) The Legal Representative

Date____________ Signature__________________

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 IX
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

HOW TO CONSULT AND KEEP THIS DOCUMENTATION


This OMM is a document written by O.M.A.C. s.r.l. and is relative to the installation, safe use and maintenance of the LDPU, in this sense, this documen-
tation, complete with the use and maintenance manuals supplied by the manufacturers of the single components, is an integral part of the LDPU.

The purpose of all the documentation mentioned above is to put the users of the LDPU in the conditions to operate safely, thus putting in place clear rules
of use; this documentation must be carefully read and understood by the users.

Please note that the specifications carried on all the use and maintenance manuals, with reference to this machine, are designed to ensure safety and
health of the users and therefore they must carefully read, understand and apply the indications/procedures.

The compliance with these indications enables the safe use of the machine, as well as the implementation of appropriate interventions.
As indicated above, the declaration of conformity and all use and maintenance technical manuals concerning the LDPU will accompany it in the event it
is sold to other users.
This documentation must be kept with care until the final demolition of the same LDPU and must be made available to the personnel appointed to ope-
rate.

It is good practice not to damage the manual and keep it properly, do not tear pages, dirty them or get them greasy, never expose them to sources of heat
and always maintain the proper layout. This documentation and relative annexes must also be made available to the personnel authorised to operate on
the LDPU, in such a way that it can be consulted easily , to clear any doubts about its safe operation and/or about the execution of use and maintenance
procedures.

What is contained in the technical manuals reflects the state of the art at the time of construction of the machine in question. The technical manuals
cannot be considered inadequate, as a result of technological improvements of the LDPU.

The technical documentation and relative annexes are completely confidential: reserves all rights related to this use and maintenance manual and
with the object presented therein. The receiving party recognises these rights to O.M.A.C. s.r.l., in the person of its legal representative, Mrs Paola
ZAVARONI, and undertakes, in the absence of an explicit written consent, not to make it accessible to others, either in whole or in part and, not to use it
outside the purpose for which it was created. Violators will be prosecuted according to law.

SYMBOLS USED
Important information, regarding the technical reliability and safe use, are highlighted in this manual in the following way (these symbols always precede
the text they refer to):

DANGER
The DANGER symbol draws attention to a procedure, practice or similar measure which, if not performed correctly, can result in injury. Do not proceed
beyond a DANGER symbol until you have fully understood and satisfied the conditions specified.

WARNING
The WARNING symbol draws attention to an operating procedure, practice or other similar measure that is potentially dangerous, which may involve risk
of serious injury, if the instructions are not followed scrupulously.

ATTENTION
The ATTENTION symbol draws attention to an operating procedure, practice or other similar measure, which if not correctly performed or observed, can
damage or completely destroy the product. Do not proceed beyond an ATTENTION symbol until you have fully understood and satisfied the conditions
specified.

NOTE
Refers to technical aspects for which the user of the equipment must pay particular attention.

O.M.A.C. s.r.l.
X Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

KEEPING THE MANUAL


The technical manuals relating to the LDPU is part of the same unit; therefore all the above mentioned technical documentation must accompany this
machine even if it is sold.

WARNING
For the proper management of safety during use and maintenance of the LDPU, all the technical documentation must accompany it even if it is sold.

DANGER
The technical manuals contain the information / procedures concerning the use and management of safe maintenance of the LDPU, it must be kept in
the vicinity of the place in which the machine operates, to which this documentation refers, in a place easily accessible by the operator responsible for its
operation. The operator responsible for its operation and the maintenance engineer must be able to find and consult this documentation at all times.

DANGER
All the technical documentation that refers to the LDPU must be kept in an easily accessible place so that it can be consulted quickly. In addition, the
personnel responsible for its use and maintenance must be informed where this documentation is kept.

LABELS APPLIED
Throughout the LDPU there are nameplates of the various components of the same unit.
The nameplate applied on the left side of the “B Series lobe displacement pump unit” (left side of the pump looking at the rotors) carries the
LDPU serial number (the serial number starts with the letter “L” and is followed by six numbers), to which the item code of the LDPU is uniquely associated
to. The coding rule of the LDPU item code is explained in section 1.2.2.

A
B

On the surfaces of the various components of the LDPU, there are plates with the prohibition to operate the LDPU dry (plate A), placed on the bearings
box of the “B Series lobe displacement pump unit”, and the plate warns the operator of the presence of mobile parts under the butt strap (plate B). In the
event of LDPUs predisposed for pumping fluids at temperatures above 50°C, there is a signal placed on the same pump that warns the operators of the
presence of high temperature surfaces, as shown in figure C:

A B C

NOTE
Please note that the markings / labels present along the LDPU cannot be removed or altered for any reason.

WARNING
It is forbidden to use any O.M.A.C. item when it is without the nameplate. Should the item be without its nameplate
it is compulsory for the customer to contact the O.M.A.C. Technical Office that will see to identify the item and re-issue the nameplate.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 XI
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

TERMS AND DEFINITIONS


OMM: Operation and Maintenance Manual.

LDPU: B Series Lobe displacement pump unit.

DANGEROUS AREAS: any area inside and/or in proximity of a machine in which the presence of an exposed person constitutes a risk
for the safety and health of this person.

EXPOSED PERSON: any person who finds himself entirely or in part in a dangerous area.

MACHINE: together of parts as defined by Article 2 of Directive 2006/42/EC of the European Parliament and the Council of 17 May, 2006

MANUFACTURER: O.M.A.C. s.r.l

CUSTOMER: Physical or legal person on whose behalf the machine is built, upon prior written acceptance of an order confirmation.

O.M.A.C. s.r.l.
XII Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 1: MACHINE AND PUMPED FLUID SPECIFICATIONS


1.1 Envisioned duration
Given the quality level of the materials and construction technologies used, if you strictly follow the instructions in this OMM (paying particular attention
to chapters 3, 4 and 5, relating, respectively, to the installation, use and maintenance of the LDPU), the expected duration of such subject matter is
estimated to be 12 months from date of installation.
Please note that, during its expected life-span, the LDPU must not be assembled and/or disassembled by unauthorised personnel and furthermore the
instructions contained in this UMM must be followed scrupulously.

1.2 Technical description of the machine


Below there is a brief description of the LDPU, as well as a functional illustrational of the B series LDPU, in order to more easily identify the main con-
struction details, mentioned in the description of use and maintenance of this document.
The LDPU is made up of 3 macro-components: 1 2 3
1) control unit (gear motor, speed controller, hydraulic motor,
electric panel, etc.);
2) mechanical transmission device (flexible transmission coupling);
3) B Series LDPU;

The B Series LDPU, identified with number 3)


is made up as follows:
A = Rotorcase cover M = Drive shaft
B = Lock nut N = Fixed gear
K
C = Rotor O = Oil level cap
D = Seal P = Adjustable gear
E = Balancing ring R = Driven shaft M
F = Bearing retainer ring S = Bearing housing
G = Front Bearing T = Foot
H = Rear bearing U = Rotorcase H N
K = Oil vent cap V = Seal protection
L = Rear cover G
F
P O
D
1.2.1 Operation principle of the B Series E L
LDPU. C R
B
The LDPU, whose functional element is the B Series V S
lobe positive displacement pump, is equipped with a
control unit that, depending on the version, can be fitted U
with a gear motor, an electric motor, a pneumatic motor
or a hydraulic motor, with or without electric panel.
The capacity adjustment is achieved by increasing or T
A
decreasing the number of revolutions of the B series
lobe positive displacement pump, intervening directly
on the revolutions output of the motor or acting on the
actuators on the control panel (inverter), if fitted.
The LDPU is reversible: full performance can be achieved in both rotation directions of the pump rotors (section 1.3.5 of chapter 1 lists the types of rotors
used).
The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of two rotors (letter “C” indicated in the figure in
section 1.2, indicating one of the two rotors), housed inside the pumping chamber (letter “U” indicated in the figure in section 1.2 or see figure below). The
rotors are assembled on rotating shafts supported by bearings (letters “G” and “H” shown in the figure in section 1.2), which are housed in the external
gearbox (letter “S” shown in the figure in section 1.2). Via a couple of sprocket wheels (letters “N” and “P” indicated in the figure in section 1.2) one
transfers motion from a drive shaft (letter “M” indicated in the figure in section 1.2) to a driven shaft (letter “R” indicated in the figure in section 1.2). The
synchronism of the rotors is such that they rotate without coming into contact with each other: in these conditions “the rotors are in time”.
When the lobes of the rotors move away from each other, the volume between them increases, creating a decrease in pressure near the suction outlet:
this enables a certain volume of fluid to enter (value of fluid transported identified in the table in section 1.3.1, in the “theoretical capacity” column,
depending on the pump model size) into the rotorcase. The fluid is transported along the internal of the pumping chamber, from the suction inlet to the
discharge outlet of the rotorcase.
When the volume of fluid, trapped between the lobes and the external perimeter of the pumping chamber, reaches in proximity of the discharge outlet,
the counter-rotation of the two rotors creates a sudden decrease of available volume and a consequent increase in pressure that pushes the fluid out of
the rotorcase, by channelling it into the plant where the LDPU is installed.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.1 - pag. 1
Rev.4 del 01/2011 O.M.A.C. s.r.l.

FRONTAL VIEW OF THE PUMP CHAMBER REAR VIEW OF THE PUMP SHAFT

WARNING
If the control unit does not comply with the rotation direction indicated in the figure,
the mechanical functionality of the LDPU is not compromised, but will not supply any delivery capacity.
Failure to comply with the proper connection to the unit (suction inlet connected to the suction piping and delivery outlet connected to the unit delivery
pipe) will cause improper installation of the LDPU by the customer.

1.2.2 B Series lobe positive diplacement pump coding


The LDPU is identified by an item code, represented by a string of 18 alphanumeric characters that starts with “K” (the item code is detectable on the first
line of the technical sheet of which there is an example in section 1.3) divided into the following structure:
K 1 1 2 3 4 5 6 7 7 7 8 8 9 V V V V
Fields 1-1: pump series = “BO”
Field 2: pump size
A = 100; B = 105; C = 110; D = 115; E = 215; F = 220; G = 325; H = 330; L = 390; M = 430; N = 440; P = 470; Q = 490;
R = 550; T = 660; U = 680;
Field 3: seal type
0 = UM type - S1 type - HN Elring type; A = Single Mechanical Silicon carbid/Carbon;
1 = Teflon packing; B = Opened frontal lip;
2 = Teflon packing + liquid barrier; C = Frontal o-ring;
3 = Single Mechanical Stainless Steel/Carbon; D = Closed frontal lip;
4 = Single Mechanical Tungsten carbid/Carbon; M = Double lip 2HN in PTFE;
5 = Single Mechanical Tungsten carbid/Tungsten carbid; N = Single lip HN in PTFE;
6 = Single Mechanical Ceramic/Carbon; P = Frontal lip in PTFE;
7 = Single Mechanical Ceramic/Rulon; Q = Single lip HN modified (heat-welded);
8 = Single Mechanical Silicon carbid/Silicon carbid; R = Double lip 2HN modified (heat-welded);
9 = Single Mechanical Tungsten carbid/Silicon carbid;
Field 4: suction-discharge connections type
0 = GAS-BSP;
1 = flanged PN16 UNI EN 1092-1 – DIN2576; A = Aseptic O.M.A.C.; J = flanged ASME 150lb;
2 = DIN 11851; B = DIN 11864/1a; K = flanged IDF;
3 = SMS; C = DIN 11864/2a; L = smooth for welding;
4 = RJT (BS); D = DIN 11864/3a; M = DS 722;
5 = IDF-ISS; E = DIN 11864/1b; N = DIN 11851 (male);
6 = TRI-CLAMP; F = DIN 11864/2b; P = MACON;
7 = GAS; G = DIN 11864/3b; Q = flanged 5044/DIN 11850;
8 = wine fitting; H = flanged PN40 UNI 6084-67/DIN 2501; R = ISO KF CLAMP;
Field 5: tipo di rotori:

0 = Trilobe Stainless Steel ST; B = Dual Wing Stainless Steel ST


1 = Trilobe/Gear Stainless Steel SM; C = Dual Wing Stainless Steel SM
2 = Bilobe Stainless Steel ST; E = Quadrilobe Stainless Steel SM
3 = Bilobe Stainless Steel SM; F = Trilobe Stainless Steel SM;
4 = Trilobe Stainless Steel ST; L = Trilobe/Gear CY5SnBIM (antiseizure) SM;
5 = Dual Wing CY5SnBIM(antiseizure) ST; M = Dual Wing CY5SnBIM (antiseizure) SM;
6 = Bilobe Stainless Steel ST; N = Trilobe CY5SnBIM (antiseizure) PR;
7 = Trilobe/Gear CY5SnBIM (antiseizure) ST; P = Dual Wing CY5SnBIM (antiseizure) PR;
8 = Gear Stainless Steel ST; Q = Gear CY5SnBIM (antiseizure) ST ultrareducted;
9 = Quadrilobe Stainless Steel ST; R = Gear CY5SnBIM (antiseizure) ST reducted;
A = Bilobo CY5SnBIM(antiseizure) ST;
(ST= standard rotor clearance; SM = increased rotor clearance; PR = exact rotor clearance)
O.M.A.C. s.r.l.
Chap.1 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

Field 6: cover type


0 = standard; 4 = with wetted o-ring; 8 = with drainage;
1 = with mechanical safety valve; 5 = for built in locking nut; A= aseptic;
2 = heated; 6 = for ultrareducted pump version; B = with mechanical safety valve and drainage;
3 = with pneumatic safety valve; 7 = for built in locking nut and heated;
Fields 7-7-7: pump single optionals
A = aseptic pump; L = rectangular suction connection; X = Atex pump certified;
B = pump o-ring in N.B.R. (Buna); M = pump in monel; Y = pump in hastelloy;
C = flushing for single mechanial seal N = niploy treatment; Z = pump in hastelloy-titanium;
in F.K.M. (°Viton); P = pump o-ring in teflon; 1 = cheniflon treatment;
D = duplex shafts; R = heated pumping case; 2 = bearing housing S.S.Aisi 304;
E = PACD treatment; S = poliuretanic lip seal; 3 = pump o-rings 3-A certified;
F = pump o-ring in kaflon 72B™; T = hydraulic flange pump; 6 = nichel-plated cast iron bearing housing;
G = inner polishing surface Ra<0.8μ; U = pump o-ring in E.P.D.M.; 7 = with feet for vertical connections disposition;
H = high pressure pump; V = pump o-ring in F.K.M. °VITON; 9 = internal mechanical seals;
J = pump in titanium; W = pump o-ring in Kalrez Spectrum6375; 0 = no options;
K = kolsterizing treatment ;
Fields 8-8: pump group optionals
C1 = flushing for single mechanial seal in NBR;
C2 = flushing for single mechanial seal in EPDM;
C3 = flushing for single mechanial seal in PTFE;
C4 = flushing for single mechanial seal in FKM;
GG = inner polishing surface Ra<0.6μ;
Q3 = secondary mechanical seal in S.S. Aisi 316 L/Carbon;
Q4 = secondary mechanical seal in Tungsten carbid/Carbon;
Q5 = secondary mechanical seal in Tungsten carbid/Carburo di Tungsteno;
Q6 = secondary mechanical seal in Ceramic/Carbon;
Q7 = secondary mechanical seal in Ceramic/Rulon;
Q8 = secondary mechanical seal in Silicon carbid/Silicon carbid;
QA = secondary mechanical seal in Silicon carbid/Carbon;
11 = connections modified diameters suction/discharge to DN20 (3/4”);
12 = connections modified diameters suction/discharge to DN25 (1”);
13 = connections modified diameters suction/discharge to DN32 (1” 1/4);
14 = connections modified diameters suction/discharge to DN40 (DN38) (1”1/2);
15 = connections modified diameters suction/discharge to DN50 (DN51) (2”);
16 = connections modified diameters suction/discharge to DN65 (DN63) (2”1/2);
17 = connections modified diameters suction/discharge to DN80 (DN73) (3”);
18 = connections modified diameters suction/discharge to DN100 (DN101) (4”);
19 = connections modified diameters suction/discharge to DN125 (5”);
21 = connections modified diameters suction/discharge to DN150 (6”);
22 = connections modified diameters suction/discharge to DN200 (8”);
23 = suction connections diameters DN125 / discharge connections diameters DN100;
24 = flanged suction connection PN16 UNI2278 / flanged discharge connection DIN11851;
28 = bearing housing S.S.Aisi 304 elettropolished;
29 = External polishing of bearing housing and pumping case

Field 9: seal model


0 = other type of seal (no mechanical); 1 = Internal seal; 2 = Fluiten KL2A seal;
3 = Fluiten KL2A sliding face reducted; 4 = Sealtek 556/S seal; 5 = Burgmann C5E seal;
7 = Roten U7K seal;

Fields V-V-V-V: progressive versioning number


Digital counter that versions the item code according to the type of accessories and type of LDPU and according to the type of associated control unit.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.1 - pag. 3
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3 Technical features


The technical data of the LDPU is listed in the “technical sheet”, of which there is an example below. The technical sheet is delivered to the Customer
together with the LDPU, in original and edited without the possibility of manual corrections.

ATTENTION DATA SHEET Mod. 13 04 del 31/07/2008


Codice Cliente Tipo Numero Data
The technical sheet must not non have any manual corrections O.M.A.C. S.r.l.
0000000000 A 0000000 __/__/__
Via G. Falcone 8 Nostro Riferimento Vostro Riferimento
or deletions. 42048 RUBIERA (RE) ITALY
Tel/Ph. 0039-0522-62.93.71 / 62.99.23
Intestatario Ordine Destinatario Merce Destinatario Ordine
Fax 0039-0522-62.89.80
http://www.omacpompe.com
E-mail: [email protected]

The technical sheet lists the item code, which identifies the
Riga Descrizione U.M. Quantità Q.tà Totale 6FRQWL Importo IVA Consegna

LDPU, the serial number (detectable on the riveted nameplate KBO000000000000000000


PUMP
NR 1 DI 1,00 __/__/_

on the bearings box of the B series lobe displacement pump),its  6HULDOQXPEHU /
PRODUCT INFO
functional features (processed fluid and its properties, pump MEDIA DESCRIPTION
VISCOSITY'
TEMPERATURE
speed, volumetric capacity, differential pressure,..) and the PUMP PERFORMANCES
FLOW-RATE
features of the B Series lobe displacement pump components. PRESSION
PUMP SPEED
TORQUE
The technical sheet below lists the technical data of the control TECHNICAL FEATURES
ABSORBED POWER

MODEL
unit (motorisation, gear motor, speed controller,..), of the flexible CERTIFICATION
ROTOS
mechanical transmission coupling, that connects the “B Series SEAL TYPE
SEAL GASKETS
SUCTION – DISCHARGE CONNECTIONS
lobe displacement pump” to the motorisation, and the type of Ø SUCTION - Ø DISCHARGE
CONNECTIONS DISPOSITION
PUMP COVER
support on which the LDPU is fitted. PUMP GASKETS
SHAFT POSITION
BEARING HOUSING OIL
NAME PLATE
SUPPORT FEATURES
TYPE
SIZE
JOINT FEATURES
TYPE
CARTER
HOLE (PUMP)
HOLE (MOTORIZATION)
PUMP ANCILLARIES
DOCUMENTS
Informativa d.lgs 30.6.2003 n. 196 TU Privacy I suoi dati personali saranno trattati, nel rispetto delle idonee misure di sicurezza, per invio di comunicazioni commerciali,
potrà esercitare i diritti previsti dalla legge e nelle modalità ivi completate. Titolare del trattamento dati è O.M.A.C. S.r.l., sede legale: 42048 Rubiera in Via G.Falcone, 8.
Per comunicazioni [email protected]. Per ulteriori informazioni www.omacpompe.com

The exploded view below highlights the position numbers of some components which will be discussed later in this chapter.

SEAL
BEARINGS
PROTECTION
par. 1.3.11
par. 1.12

MECHANICAL
SEALS
par. 1.3.7

ROTORS par. 1.3.4 - par. 1.3.5

O.M.A.C. s.r.l.
Chap.1 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.1 Technical features of the B Series lobe positive displacement pump


The table below shows the nominal features of the various dimensions of the B series lobe displacement pump, inserted in the LDPU. The data that make
up the table refer to the pump model, the capacity that each pump model (B100, B105, B110...) elaborates every 100 revolutions, the maximum operation
speed of each pump size, the differential operating pressure, expressed in bar, and the standard dimensions of the opening couplings, expressed in
millimetres and inches.

PUMP THEORETIC MAXIMUM MAXIMUM MAXIMUM OPERATING PRESURE (bar) STANDARD


MODEL CAPACITY SPEED POWER CONNECTION
lt/100 rpm rpm kW rotor clearances ST (standard) rotor clearances SM (increased) High pressure
with shafts with shafts Duplex + Acteon
S.S. AISI 316 L DUPLEX S.S. AISI 316 L DUPLEX DN Inches
B100 3 1400 1.5 7 10 - - - 25 1”
B105 7 1000 4 10 13 15 18 - 40 1” 1/2
B110 12 1000 4 10 13 15 18 20 40 1” 1/2
B115 18 1000 5.5 7 10 12 15 - 40 1” 1/2
B215 23 950 7.5 10 13 15 18 20 40 1” 1/2
B220 34 950 7.5 7 10 12 15 - 50 2”
B325 55 720 18.5 10 13 15 18 20 65 2” 1/2
B330 70 720 18.5 7 10 12 15 - 80 3”
B390 90 720 18.5 5 7 10 12 - 80 3”
B430 116 600 30 10 13 15 18 20 80 3”
B440 155 600 30 7 10 12 15 - 100 4”
B470 240 500 45 10 13 15 18 20 100 4”
B490 330 500 45 7 10 12 15 - 100 4”
B550 400 500 45 5 - 7 - - 125 5”
B660 700 500 75 7 - - - - 150 6”
B680 1050 500 75 4 - - - - 200 8”

1.3.2 Variation of maximum operating pressure according to temperature


The table below lists the maximum differential pressure values, processed by the B series lobe displacement pump, inserted in the LDPU, according to
the size of the pump (from B100 to B680), according to the temperature of the processed fluid (from 0-70°C, 90°C, 110°C,..) and according to the type of
rotors fitted: with clearances between rotor and ST standard pumping chamber, SM increased clearances or clearances for HP high pressures.
The values of these clearances between rotors and pumping chamber are shown in the section 1.3.4.
TEMPERATURE

B SERIES MODEL PUMP


ROTOR
TYPE
°C

B100 B105 B110 B115 B215 B220 B325 B330 B390 B430 B440 B470 B490 B550 B660 B680

ST 7 10 10 7 10 7 10 7 5 10 7 10 7 5 7 5
0°C
SM - 15 15 12 15 12 15 12 10 15 12 15 12 7 10 7
a 70°C
HP - - 20 - 20 - 20 - - 20 - 20 - - - -
ST 5.2 8.8 8.9 6.5 9 6.5 9.1 6.5 4.5 9.1 6.4 9.1 6.3 4.4 6.4 4.4
90°C SM - 15 15 12 15 12 15 12 10 15 12 15 12 7 10 7
HP - - 18.8 - 18.9 - 19 - - 19 - 19 - - - -
ST 4 7.6 7.8 5.7 8 5.9 8.2 6 - 8.4 5.8 8.4 5.9 5.8 5.8 3.9
110°C SM - 15 15 12 15 21 15 12 - 15 12 15 12 10 10 7
HP - - 17.6 - 17.7 - 18 - - 18 - 18 - - - -
ST 3.4 7 7.3 5.5 7.5 5.6 7.8 5.7 - 7.9 5.5 7.8 5.4 3.7 5.5 3.7
120°C SM - 14 14.6 11.7 14.5 11.7 14.5 11.7 - 14.6 11.7 14.6 11.6 6.8 9.5 6.8
HP - - 17.1 - 17.2 - 17.6 - - 17.5 - 17.5 - - - -
ST 2.2 6 6.3 5.1 6.5 5 7 5.2 - 7.2 4.9 7.2 4.9 3.2 4.9 3.2
140°C SM - 13 13.6 11.3 13.6 11.1 13.8 11.2 - 13.7 11.1 13.7 11.1 6.4 8.6 6.4
HP - - 16.1 - 16.3 - 16.8 - - 16.6 - 16.6 - 2.6 - -
ST - - 5.3 5 5.5 4.4 6.1 4.6 - 6.4 4.3 6.4 4.2 2.6 4.3 2.6
160°C SM - - 12.7 10.8 12.7 10.5 12.9 10.7 - 12.9 10.4 12.7 10.4 6 7.8 6
HP - - 15.1 - 15.3 - 15.8 - - 15.8 - 15.6 - - - -
ST - - 4.3 4.2 4.5 3.9 5.2 4.1 - 5.5 3.6 5.4 3.6 2 3.6 2
180°C SM - - 12.1 9.9 11.8 10.5 12.1 10.1 - 12 9.7 12 9.7 5.5 6.9 5.5
HP - - 14.1 - 14.3 - 14.9 - - 14.9 - 14.6 - - - -

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.1 - pag. 5
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.3 Motorization and transmission coupling technical features


The mechanical features of the flexible transmission coupling and the performance features of the control unit (electrical, pneumatic, hydraulic), accor-
ding to the type of operation chosen by the customer, are shown in the respective use and maintenance manuals; documents that are supplied with the
LDPU.

1.3.4 Rotors clearances


This section lists the nominal clearances (ST standard, SM increased), that are recorded between rotors
and walls of the pumping chamber according to the material (AISI 316 L, anti-friction alloy CY5SnBIM).
The figure, on the next page, represents a rotor section, fitted in the pumping chamber, with indication
of clearances, identified by letters A,B,C,D. The table below shows the entity of these clearances.
The “S” value represents the protrusion of the shaft compared to the wall of the pumping chamber.

ROTORS S.S. AISI 316 L ROTORS S.S. AISI 316 L ROTORS ANTISEIZURE SHAFT
ST VERSION SM VERSION CY5SnBIM PROTRUSION
A B C D A B C D A B C D S
B100 0.12 0.12 0.15 0.2 0.15 0.15 0.2 0.2 0.07 0.08 0.19 0.15 0.12
B105 0.12 0.14 0.15 0.25 0.17 0.19 0.2 0.3 0.05 0.05 0.13 0.15 0.12
B110 0.14 0.14 0.15 0.3 0.19 0.19 0.23 0.3 0.08 0.07 0.15 0.2 0.14
B115 0.14 0.14 0.18 0.3 0.19 0.19 0.22 0.3 0.07 0.08 0.2 0.2 0.14
B215 0.15 0.15 0.18 0.3 0.22 0.23 0.3 0.3 0.08 0.07 0.18 0.2 0.15
B220 0.15 0.17 0.23 0.3 0.25 0.25 0.32 0.3 0.08 0.07 0.2 0.2 0.15
B325 0.17 0.17 0.2 0.35 0.25 0.25 0.32 0.35 0.08 0.08 0.2 0.2 0.17
B330 0.17 0.19 0.23 0.35 0.27 0.28 0.32 0.35 0.09 0.08 0.23 0.2 0.17
B390 0.17 0.19 0.23 0.35 0.27 0.28 0.32 0.35 0.09 0.08 0.23 0.2 0.17
B430 0.18 0.18 0.22 0.35 0.27 0.27 0.32 0.35 0.09 0.08 0.23 0.2 0.18
B440 0.18 0.18 0.22 0.35 0.27 0.27 0.32 0.35 0.1 0.1 0.25 0.2 0.18
B470 0.2 0.2 0.27 0.35 0.32 0.32 0.35 0.35 0.09 0.09 0.25 0.2 0.2
B490 0.23 0.23 0.3 0.35 0.35 0.35 0.35 0.45 0.09 0.09 0.25 0.2 0.23
B550 0.22 0.22 0.3 0.4 0.32 0.32 0.43 0.4 0.15 0.15 0.35 0.25 0.22
B660 0.27 0.27 0.35 0.5 0.37 0.37 0.5 0.5 - - - - 0.27
B680 0.3 0.35 0.35 0.5 0.37 0.37 0.5 0.5 - - - - 0.27

Dimensions expressed in mm - Tolerances 0/+0.03

1.3.5 Rotors geometry


The table below shows the types of rotors, per type of construction material and geometric shape, available for every size of “B series lobe pump”.

B SERIES MODEL PUMP


ROTOR TYPE
B100 B105 B110 B115 B215 B220 B325 B330 B390 B430 B440 B470 B490 B550 B660 B680
GEAR S.S. AISI 316 L ● ●
GEAR CY5SnBIM ● ●
DUAL-WING S.S. AISI 316 L ●
DUAL-WING CY5SnBIM ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
TRILOBE S.S.AISI 316 L ● ● ● ● ● ● ● ● ● ● ● ● ● ●
TRILOBE CY5SnBIM ● ● ● ● ● ● ● ●
RUBBER COATED TRILOBE (*) ● ● ● ● ● ● ● ●
BILOBE S.S.AISI 316 L ● ● ● ● ● ● ● ● ● ● ● ● ●
BILOBE CY5SnBIM ● ● ● ● ● ● ● ● ●
RUBBER COATED BILOBE ● ● ● ● ●

(*) Penta-lobe for B100 and B105

O.M.A.C. s.r.l.
Chap.1 - pag. 6 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.6 Tightening torque


This table shows the tightening torque values, to be used as reference during all assembly and disassembly operations of pump components, in one or
more parts.The values mentioned in the table below relate to gear adjustment, rotor blocking, pumping body blocking, front cover blocking, bearing ring
blocking and gear ring blocking.

GEAR ADJUSTMENT ROTOR LOCKING PUMPING CASE LOCKING FRONT COVER LOCKING
(pos.8, pag.15) (pos.42, pag.15) (pos.52, pag.15) (pos.51, pag.15)
PUMP MODEL

TORQUE

TORQUE

TORQUE

TORQUE
/ Size [mm]

/ Size [mm]

/ Size [mm]

/ Size [mm]
Key type

Key type

Key type

Key type
d x pitch

d x pitch

d x pitch

d x pitch
Thread

Thread

Thread

Thread
[Nm]

[Nm]

[Nm]

[Nm]
B100 M4X0.7 A/7 3 M8X1 A/17 25 M6X1 A/10 10 M6X1 A/10 10
B105 B110 B115 M5X0.8 B/4 5 M12X1 A/27 85 M8X1.25 A/13 30 M8X1.25 A/13 30
B215 B220 M6X1 B/5 10 M14X1.5 A/30 190 M10X1.5 A/17 50 M10X1.5 A/17 50
B325 B330 B390 M8X1.25 B/6 20 M20X1.5 A/38 305 M12X1.75 A/19 70 M10X1.5 A/17 50
B430 B440 M10X1.25 B/8 50 M24X2 A/46 480 M16X2 A/24 115 M12X1.75 A/19 70
B470 B490 M10X1.25 B/8 50 M24X2 A/46 480 M20X2.5 A/30 180 M14X2 A/22 95
B550 M12X1.75 A/19 70 M24X2 A/46 500 M14X2 A/22 115 M12X1.75 A/19 70
B660 B680 M16X2 A/24 170 M36X2 A/60 600 M14X2 A/22 115 M14X2 A/22 70

BEARING RING NUT LOCKING GEAR RING NUT LOCKING


(pos.21, pag.15) (pos.42, pag.15)
PUMP MODEL

The “A” type spanner - ref. “spanner type” column - is a


polygonal spanner; the “B” type spanner - ref. “spanner
TORQUE

TORQUE
/ Size [mm]

/ Size [mm]
Key type

Key type
d x pitch

d x pitch
Thread

Thread
[Nm]

[Nm]

type” column - is hexagonal (inbus or imbus).

B100 - - - M20X1 HN4 50


B105 B110 B115 M30X1.5 HN6 90 M30X1.5 HN6 90
NOTE
B215 B220 M40X1.5 HN8 105 M35X1.5 HN7 90 With regard to the tightening torque value of the elemen-
B325 B330 B390 M50X1.5 HN10 115 M40X1.5 HN8 105 ts that make up the LDPU, please refer to the use and
B430 B440 M70X2 HN14 220 M60X2 HN12 145 maintenance manuals (flexible transmission coupling,
B470 B490 M80X2 HN16 400 M70X2 HN14 220 motorisation).
B550 M70X2 HN14 220 M70X2 HN14 220
B660 B680 - - - M100X2 HN20 600

1.3.7 Mechanical seals overall dimensions


Below there are the overall dimensions of the mechanical seals fitted on the B series lobe pump, according to the size of the pump and the position of
the seal. The drawing below shows the references relative to the main dimensions of the mechanical seals, whose values, in mm, are shown in the table,
according to the size of the pump.

B105 B325
B215 B430 B470 B660
B100 B110 B330 B550
B220 B440 B490 B680
B115 B390

d1 20 30 35 50 65 80 65 100
d6 29 39 44 62 77 95 77 115
d7 35 45 50 70 85 105 85 125
L1 29.1 29.1 29.1 34.1 38.8 43.8 38.8 41.3
L2 44 44 44 50 55.5 59 55.5 85
L3 19.1 19.1 19.1 21.1 25.8 25.8 25.8 25.8
L4 10 10 10 13 13 18 13 15.5
L5 2 2 2 2.5 2.5 3 2.5 3
L6 5 5 5 6 6 7 6 7
L7 9 9 9 9 9 9 9 9

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.1 - pag. 7
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.8 Weights and dimensions table of the B Series lobe positive displacement pumpe
The table below shows the dimensions of the B series lobe pump, with reference to its size and according to the type of connections it is equipped with.
With regard to the dimensions of the LDPU, these vary according to the type of control unit supplied, therefore they must be expressly requested to the
O.M.A.C. Technical Office.

PUMP WITH CONNECTIONS IN HORIZONTAL POSITION

PUMP WITH CONNECTIONS IN VERTICAL POSITION

I1
1
1

1 1 1 1

1 1

O.M.A.C. s.r.l.
Chap.1 - pag. 8 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

MODEL PUMP
POSITION
B100 B105 B110 B115 B215 B220 B325 B330 B390 B430 B440 B470 B490 B550 B660 B680

C 115.5 181 181 181 235.5 235.5 270 270 270 367.5 367.5 442.5 442.5 515 690 690

D 18 24 24 24 28 28 35 35 35 48 48 55 55 55 80 80

E 43.5 50 50 50 55 55 65 65 65 85 85 110 110 110 140 140

F 65 65 65 65 90 90 120 120 120 140 140 150 150 20 300 300

F1 - 49 49 49 87 87 110 110 110 135 135 175 175 - - -

G 105 105 105 105 125 125 140 140 140 190 190 250 250 300 300 400

G1 - 124 124 124 166 166 192 192 192 270 270 320 320 - - -

H 80 125 125 125 165 165 190 190 190 255 255 300 300 350 480 480

H1 - 150 150 150 155 155 175 175 175 210 210 300 300 - - -

I - 62 62 62 90 90 100 100 100 130 130 160 160 178 250 250

I1 - 31.5 31.5 31.5 37.5 37.5 45 45 45 62.5 62.5 70 70 - - -

L 265 290.5 290.5 302.5 365.5 380.5 459 474 494 543.5 563.5 654 684 637 807 867

N 58.6 93.5 93.5 93.5 127.5 127.5 145 145 145 192.5 192.5 230 230 264 365 365

N1 - 62.5 62.5 74 81 90 107 116 136 119 126.5 118.5 148 - - -

O 9 10 10 10 12 12 14 14 14 18 18 22 22 19 26 26

P 125 128 128 128 152 152 174 174 174 235 235 300 300 350 460 460

P1 - 180 180 180 240 240 272 272 272 360 360 430 430 - - -

Q 92 90 90 90 130 130 170 170 170 195 195 255 255 250 360 360

Q1 - 75 75 75 115 115 140 140 140 170 170 220 220 - - -

R 110.5 115.5 115.5 115.5 136.5 136.5 167 167 167 206.5 206.5 255 255 227 283 283

R1 110.5 98.5 98.5 98.5 108.5 108.5 134 134 134 165.5 165.5 210 210 - - -

S 52 55.5 55.5 67 78 87 94 103 123 109 116.5 143.5 173 106.5 122 152

T 20.5 27 27 27 31 31 38.5 38.5 38.5 52 52 60 60 60 85 88

U 6 8 8 8 8 8 10 10 10 14 14 16 16 16 22 22

V 49.5 42.5 42.5 54 52 61 62 71 91 76.5 84 63.5 93 81.5 92 122

Y - M6 M6 M6 M8 M8 M10 M10 M10 M12 M12 M12 M12 M12 M16 M16

Kg. 10.5 20 20 21 41 43 63 65 69 130 135 225 233 270 610 670

A 1” 1” 1/2 1”1/2 1”1/2 1”1/2 2” 2”1/2 3” 3“ 3” 4” 4” 4” - - -


GAS
B 160 170 170 170 208 208 236 236 236 335 335 385 385 - - -
BSP
C1 - 235 235 235 259 259 293 293 293 377.5 377.5 492.5 492.5 - - -
FLANGED A DN25 DN40 DN40 DN40 DN40 DN50 DN65 DN80 DN80 DN80 DN100 DN100 DN100 DN125 DN150 DN200
UNI
B 165 186 186 186 224 228 256 256 256 355 355 405 405 566 680 670
1092
ex 2278
C1 - 243 243 243 267 269 303 303 303 387.5 387.5 502.5 502.5 - - -
PN16
A DN25 DN40 DN40 DN40 DN40 DN50 DN65 DN80 DN80 DN80 DN100 DN100 DN100 DN125 - -
DIN
B 160 210 210 210 248 248 296 296 296 395 395 445 445 632 - -
11851
C1 - 255 255 255 279 279 323 323 323 407.5 407.5 522.5 522.5 - - -
A DN25 DN38 DN38 DN38 DN38 DN51 DN63 DN76 DN76 DN76 DN101 DN101 DN101 - - -
SMS B 150 210 210 210 248 248 296 296 296 395 395 445 445 - - -
C1 - 255 255 255 279 279 323 323 323 407.5 407.5 522.5 522.5 - - -
A DN25 DN38 DN38 DN38 DN38 DN51 DN63 DN76 DN76 DN76 DN101 DN101 DN101 - - -
IDF-ISS B 153 210 210 210 248 248 296 276 276 375 378 428 428 - - -
C1 - 255 255 255 279 279 323 323 323 397.5 399 514 514 - - -
A DN25 DN38 DN38 DN38 DN38 DN51 DN63 DN76 DN76 DN76 DN101 DN101 DN101 - - -
RJT B 157 210 210 210 248 248 290 286 286 385 389 439 439 - - -
C1 - 255 255 255 279 279 320 318 318 402.5 404.5 519.5 519.5 - - -
A 1” 1”1/2 1”1/2 1”1/2 1”1/2 2” 2”1/2 3” 3” 3” 4” 4” 4” - - -
TRI
B 160 210 210 210 248 248 293 290 290 389 392 442 442 - - -
CLAMP
C1 - 255 255 255 279 279 321.5 320 320 404.5 406 521 521 - - -
For other connections please contact the Technical Department Omac

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.1 - pag. 9
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.9 Dimensions of pumping case connections, equipped with heating/cooling chamber and flushing
seals.
At times the Customer may request, according to the production needs, to heat/cool the pumping chamber or to fit some flushed mechanical seals (for
further information please refer to section 1.11). The dimensions of the heating / cooling fluid inlet and outlet holes of the pumping chamber and the
dimensions of the flushing holes of the mechanical seals are shown in the following table and are divided per pump model.
Dimensions A, B and C are expressed in inches, dimensions D, E, F, G, L in millimetres.
PUMP MODEL
POS.

DESCRIPTION
B100 B105 B115 B215 B220 B325 B330 B390 B430 B440 B470 B490 B550 B660 B680
B110
A Seal flushing holes - 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” 1/4” 1/4”

B Rotor case heating fluid - 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 3/4” 3/4” 3/4” 3/4” 3/4”
connections size

C End cover heating fluid 1/8” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 3/4” 3/4” 3/4” 3/4” 3/4”
connections size

D Distance between end 56 75 75 100 100 122 122 122 150 150 180 180 180 300 300
cover fluid connections
E Nut heigh 12 15 15 18 18 18 18 18 22 22 25 25 24 27 27

F End cover heating 17 20 20 20 20 20 20 20 18 18 23 23 23 30 30


chamber thickness

G End cover heating 104 126 126 156 156 179 179 179 219 219 280 280 280 400 400
chamber diameter
L Pump lenght 256 295.5 307.5 367.5 382.5 461 476 476 543.5 563.5 654 684 637 807 867

FLUSHING DISPOSABLE CIRCUIT


The drawing on the right shows the connection method of the
seals flushing system, with indication of the flushing liquid cir-
culation direction. Carefully read and understand the flushing
ATTENTION operation methods described in section 5.7.4.

HEATING / COOLING
PUMPING CASE AND FRONT COVER FLUSHING CIRCUIT WITH TANK

1.3.10 Suction inlet dimensions in “widened rectangular inlet port” version of the B Series lobe positive
displacement pump
To facilitate handling of viscous fluids or fluids that contain a percentage of solids, O.M.A.C. s.r.l. has designed and made a B series lobe displacement
pump with a widened rectangular suction inlet (see indication in the drawing below).
POSITION
For design requirements, this optional feature is available only on models
PUMP
B115, B220, B330, B440, B490. The figure below shows the position of the
MOD. A B C D E F G H L M
widened rectangular inlet on the pumping chamber, and the table shows,
B115 40 22 18 90 70 42 23 19 61 120
according to the model type, the dimensions of the inlet, as well as the
B220 55 31 24 110 92 54 32 22 72 150 dimensions of the B Series lobe displacement pump.
B330 75 37 38 146 133 65 32 33 93 176

B440 75 32.5 42.5 230 180 81 40.5 40.5 115 248

B490 107 67 40 230 180 107 69 38 143 256

PUMP POSITION

MOD. N O P Q R S T U V Z

B115 67 M6 64 154 6 55 35 93.5 94 M8

B220 87 M8 78 210 15 67 67 127.5 114 M10

B330 103 M8 95 236 12.5 70 85 145 143.5 M12

B440 116.5 M10 122.5 320 12.5 100 100 192.5 161.5 M14

B490 173 M12 152.5 370 12.5 130 135 230 190.5 M20

O.M.A.C. s.r.l.
Chap.1 - pag. 10 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.3.11 Bearings
The two tables to the side show, PRE-ASSEMBLED BEARINGS ISO BEARINGS
according to the pump size, the PUMP MODEL PUMP MODEL
identity abbreviations of the bearin- FRONT REAR FRONT REAR

gs fitted on the transmission shafts B105 B110 B115 32006X TLA 3020 Z
of the B Series lobe displacement B100 NATB 5904
B215 B220 32008X 32007X LRT 253020
pump, inserted in the LDPU.
B325 B330 B390 32010X 32008X B550 NJ 2216 E 3214

B430 B440 32014X 32012X B660 B680 NJ 224 E 3220

B470 B490 32016X 32014X

The front bearing has position number 29, whilst the rear bearing has position number 30, with reference to the exploded view of page 5 in this chapter.
• The bearings of pump mod. B100 are ISO standard radial rollers type. The radial rear roller bearings combined with NATB 5904 oblique ball
bearings, undergo an assembly adaptation to cancel the axial play.
• The bearings of pump mod. B5 - B6 are ISO standard cylindrical and oblique type with two rows of balls, commonly available on the market.
• The bearings of pump mod. B1 - B2 - B3 - B4 - B470 – B490 are made up of two metric bearings with a single row of conical rollers, by a
spacer for the internal rings and by a spacer for the external rings. The assembly of the bearings is performed accurately by our technicians to ensure
ideal rotation without play. For this reason, these bearings must be requested directly from O.M.A.C. s.r.l. that supplies them already pre-assembled with
the right pre-load.
• The duration of the bearings varies significantly according to the varying of the working conditions (speed, pressure, absorbed power) and
therefore one cannot define it beforehand.

1.3.12 Lubricants used and quantities


The three tables show the general features of lubricant oil that can be used to lubricate bearings and sprocket wheels.
Tables A and B show the type of oil to be used according to the temperature of the processed fluid (from -20°C to +90°C, and from +90°C to +150°C):
table A only refers to lobe displacement pump models B100, B105, B110, B115, B215, B220, B325, B330, B390, B430, B440, B470, B490; table B only
refers to lobe displacement pump models B550, B660, B680.
The lines of the table that refer to “BRAND” list a series of possible suppliers where the lubricant can be bought.
WORKING
WORKING TEMPERATURE PUMP MODEL LITERS
TEMPERATURE
from -20°C from +90°C to PUMP
PUMP MODEL BRAND BRAND da -20°C a +150°C
to +90°C +150°C MODEL
(viscosità olio B100 0.2
(oil viscosity (oil viscosity
ISO VG 150)
ISO VG 68) ISO VG 150)
ESSO SPARTAN EP 68 SPARTAN EP 150 ESSO SPARTAN EP 150 B105 B110 B115 0.5
B100
SHELL OMALA OIL 68 OMALA OIL 150 SHELL OMALA OIL 150 B215 B220 1
B105 B110 B115
CASTROL ALPHA SP 68 ALPHA SP 150 B550 CASTROL ALPHA SP 150 B325 B330 B390 2.2
B215 B220
BP ENERGOL GR-XP 100 ENERGOL GR-XP 150 B660 BP ENERGOL GR-XP 150 B430 B440 4.5
B325 B330 B390
MOBIL MOBILGEAR 626 MOBILGEAR 629 B680 MOBIL MOBILGEAR 629 B470 B490 6.7
B430 B440
AGIP BLASIA 68 BLASIA 150 AGIP BLASIA 150 B550 15
B470 B490
FINA GIRAN 100 GIRAN 150 FINA GIRAN 150 B660 B680 30
table A table B table C
Table C shows the amount of lubricant, expressed in litres, to be inserted in the gear box, according to the pump size, and after having removed the
previous exhausted oil, as described in chapter 5.
Should it be expressly requested by the customer, the B series lobe pump can be equipped with alimentary type lubricant oil, NSF certified in H1 cate-
gory.

1.4 Intended use


The “B Series Lobe Displacement Pump Unit”, marketed by O.M.A.C. s.r.l., which in this documentation will be indicated with the abbreviation LDPU, has
been designed and made to be assembled in industrial plants owned by third parties, to transfer volumes of fluids, compatible with the materials used
during the construction of this machine: section 1.4.1 lists the recommended operational features of the LDPU, depending on the processed fluid.
The LDPU requires compliance with all technical indications in this use and maintenance manual, which in this documentation will be indicated with the
abbreviation UMM, for its proper installation.
In general, the processed fluids must meet the following specifications:
Fluid properties and range of use:

1) TEMPERATURE: from -35°C to +180°C


2) VISCOSITY: Maximum 200’000cPs with forced feeding
3) HARD PARTICLE SIZE: Maximum 80% of clearance between rotors (see sect.1.3.4)

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.1 - pag. 11
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

The LDPU has been designed and made for two types of use:
• alimentary use;
• chemical use.

WARNING:
The LDPU, for alimentary use, has been made to ensure a hygienic standard equal to LEVEL 1, on the basis of UNI EN 13951.
The LDPU for alimentary use and for chemical use has been designed to transfer volumes of fluids without altering the organoleptic properties nor the
physical properties.

WARNING:
During its normal use, the LDPU for alimentary use and chemical use does not alter the organoleptic characteristics nor the physical characteristics of
the processed fluid.

Every LDPU comes with a technical sheet indicating the operational features in relation to the processed fluid that must be handled (name of the
fluid, viscosity range, capacity range, speed range, temperature range), as declared at the time of purchase by the Customer.
Section 1.3 shows a facsimile of the LDPU technical sheet.
Every modification to what is indicated in the specific technical sheet or variation of the machine operating parameters must be authorised in writing by
O.M.A.C. s.r.l.; the absence of such authorisation is deemed “improper use” and will void any warranty or liability under way between Manufacturer and
Customer.

DANGER:
Any use of the LDPU in conditions other than those indicated in “Fluid properties and range of use” and in conditions other than those indicated in the
machine technical sheet is forbidden, without explicit written authorisation, issued by O.M.A.C. s.r.l.

The LDPU for alimentary use and for chemical use has NOT been designed nor built to handle pharmaceutical, explosive, etc. fluids, and in general
fluids that do not comply with the indications of the specific technical sheet. In addition, the LDPU for alimentary use and chemical use has NOT been
designed nor built to handle what is indicated in Regulation (EC) No. 1005/2009 of the European Parliament and the Council of 16 September, 2009, on
substances that deplete the ozone layer.

ATTENTION:
It is forbidden to use the LDPU for alimentary use and chemical use to transfer the substances listed in Annex I of Regulation No. 1005/2009.

The pumping part of the LDPU is made up of the pump body, in which two rotors are housed (sect. 1.3.5 lists the types of rotors used), which rotate
synchronised in the opposite direction to each other.
The pump body receives the process fluid from the suction inlet, originating from the plant of the Customer. During the operation of the LDPU, the
cavities between the lobes of the rotors are filled with fluid and the counter-rotation of the rotors transfers the fluid to the delivery outlet of the pump body,
channelling it in the plant where the LDPU is installed.

1.4.1 Recommended use guidelines for the transfer of some types of processed fluid
As an example, the following table lists some types of fluids that can be processed by the “B series lobe displacement pump”, part of the LDPU; for each
one, we suggest a value or range of viscosity, fluid temperature, pump rotation speed, O.M.A.C. identification code of materials for seals, gaskets and
rotors (see coding section 1.2.2).
The application requested by the customer is examined by the O.M.A.C. s.r.l. Technical Office, which edits the technical sheet of the LDPU, specifically
for the requested application.
Therefore, in all cases and without any exceptions, one must comply with the technical specifications, shown in the technical sheet of the B series lobe
displacement pump unit, these specifications have absolute priority over the data shown in the next table.

ATTENTION
On the basis of the features of the processed fluid, O.M.A.C. identifies and uses materials compatible with the proper processability of the fluid, and these
features are specifically mentioned in the technical sheet of the LDPU.
O-RING

VISCOSITY TEMPERATURE SPEED SEALS ROTORS


PRODUCTS
cPs °C RPM 1° 2° 1° 2°

DAIRY PRODUCTS
MILK 2 18 250-400 3 0 T 0 -
YOGHURT 50-150 20-40 250-350 6 3 T 0 -
BUTTER 50000 4 20-70 5 - T 5 -
CREAM 30% 14 16 250-350 3 0 T 0 -
CURD 20-500 10 50-200 3 0 T 0 5
CONDENSED MILK 40-80 40 250-450 3 0 T 0 -

O.M.A.C. s.r.l.
Chap.1 - pag. 12 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

O-RING
VISCOSITY TEMPERATURE SPEED SEAL ROTORS
PRODUCTS
cPs °C RPM 1° 2° 1° 2°

CONDENSED MILK 75% S.S. 2000 20 200-400 5 3 T 0 -


MELTED BUTTER 40 50 300-400 5 - T 0 -
PROCESSED CHEESE 30000-6500 18-80 200-400 5 - T 0 5
COTTAGE CHEESE 30000 18 50-150 5 - T 0 5
WHEY 1 20 300-500 3 0 T 0 -
MILK ENZYMES 5 10 250-300 3 0 T 0 -
FOOD PRODUCTS
ICE-CREAM 400 10 200-300 5 0 T 0 5
BROTH 1-400 20 250-450 5 3 T 0 -
COCOA BUTTER 50-0.5 60-100 300-400 5 - T 0 -
ANIMAL FATS 60 40 250-400 3 - T 0 -
MEAT EXTRACT 10000 65 200-350 5C - T 0 -
MAYONNAISE 20000 20 200-300 5 - T 0 -
MALT EXTRACT 3000-9500 18-60 200-300 5 1 T 0 -
SUGAR CANDY 30000 20 150-250 5C 1 T 0 5
MOLASSES 280-15000 40 150-300 5 1 T 0 5
JAM 8000 16 200-350 5 - T 0 5
HONEY 1500 40 250-350 5 - T 0 -
WHOLE EGGS 150 4 200-350 6 5C T 0 -
BREWER’S YEAST 350 18 300-400 5 - T 0 -
SOYA LECITHIN 6000 50 200-300 5 - T 0 -
OLIVE OIL 40 38 250-350 5 3 T 0 -
VARIOUS SEED OIL 20-60 20 250-350 5 3 T 0 -
MINCED MEAT 100000 30 20-150 5 1 T 5 -
PECTIN 300 30 300-400 3 5 T 0 -
MAIZE PORRIDGE 100 100 100-200 1 0 T 0 -
COOKIE PASTRY 5000-10000 18 50-150 5 - T 5 0
CHOCOLATE 200-2000 18-40 50-150 0 1 T 0 -
ICING 500-2000 18 100-300 5 - T 5 0
BRINE 1 20 300-450 6 5 T 0 -
TOMATO SAUCE 10 20 200-300 5 - T 0 -
DICED TOMATO 10 20 50-200 5 - T 5 -
TOMATO PURREÉ 7000 20 150-250 5 - T 0 -
TOMATO TRIPLE PURREÉ 12000 18 150-250 5 - T 0 -
TOMATO PASTE 200 18 200-300 5 - T 0 -
KETCHUP 1000 30 200-300 5 - T 0 -
DRINKS
GLUCOSE 4300-8600 25-30 200-300 5C - T 0 -
SORBITOL 200 20 250-350 5 - T 0 -
30° BRIX 4 10 300-400 5 - T 0 -
40° BRIX 10 10 300-400 5 - T 0 -
50° BRIX 25 10 300-400 5 - T 0 -
SUGAR SOLUTIONS
60° BRIX 60 18 300-400 5 - T 0 -
70° BRIX 550 18 250-350 5 - T 0 -
80° BRIX 6000 30 200-300 5 - T 0 -
VINEGAR 15 20 300-500 3 - T 0 -
WINE 1 18 350-750 3 - T 0 -
SPIRITS 10-100 20 250-400 5 - T 0 -
ALCOHOL 1 18 300-500 3 - T 0 -
GRAPE JUICE 1 18 350-450 5 - T 0 -
BEER 1 18 300-400 3 - T 0 -
POTATO PUREÉ 400-4000 18 150-300 5 - T 0 5
FRUIT JUICE 20-80 18 250-400 5 - T 0 -
CONCENTRATED ORANGE JUICE 5000-500 5-20 200-300 5 - T 0 -

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.1 - pag. 13
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

O-RING
VISCOSITY TEMPERATURE SPEED SEALS ROTORS
PRODUCTS
cPs °C RPM 1° 2° 1° 2°

COSMETICS AND PHARMACEUTICAL PRODUCTS


DODECILBENZENSULPHONIC ACID 6000 18 300-400 5 - V 0 -
DETERGENTS 100-4000 18 250-400 5 3 V 0 -
HAND CREAM 800-35000 20 150-350 5 3 V 0 -
SHAMPOO 2000 20 250-350 5 3 T 0 -
HAIR GEL 5000 20 250-350 5 3 T 0 -
NAIL POLISH 10000 20 250-350 5 - P 0 -
SOAP 3000 20 150-250 1 - V 0 -
TOOHPASTE 100000 18 50-150 5 1 V 0 -
HYDEROGEN PEROXIDE 1 15 300-400 7 5 V 0 -
GLYCERINE 600 18 250-350 6 4 T 0 -
VASELINE 30000-500 10-40 40-350 5 - T 0 -
INDUSTRIAL PRODUCTS
CITRIC ACID 1 20 300-450 3 - T 0 -
SULPHONIC ACID 125 30 250-400 5 6 V 0 -
NEUTRALIZED ETHOXYL ALCOHOLS 200-600 60-30 300-400 5 - P 0 -
ISOPROPYL ALCOHOL 1 20 300-400 3 - U 0 -
FLAVOUR FOR TOBACCO 10-100 20 300-450 5 3 T 0 -
FERMENTATION SOUP 20 20 250-350 3 - T 0 -
CELLULOSE 6000-15000 18 250-350 5C - P 0 -
WAX 500 93 200-300 5 - T 0 -
VINYL GLUE 1500 18 200-300 5C 1 V 0 -
UREIC PHENOLIC GLUE 600 20 200-300 5C 1 P 0 -
LATEX EMULSION 200 20 300-400 5C - P 0 -
PARAFFIN EMULSION 3000 18 250-350 5 - V 0 -
ETHYLENE 20 20 250-400 3 - T 0 -
ETHYLENE GLYCOL 10 20 250-400 3 - T 0 -
PRINTING INK 500-2000 35 300-500 6 - V 0 -
FLUID SILICONS 500 40 300-400 5C - P 0 -
DYES 1-200 20 300-500 6 - V 0 -
ACRYLIC RESIN 5000 20 200-300 5C 1 P 0 -
ALKYL RESIN 180-900 5-40 250-350 5C 1 V 0 -
VINYL RESIN 5500 20 200-300 5C 1 V 0 -

1.5 Material specifications


Below, listed per each component (bearings box, rear cover, pumping body,..) of the B Series lobe displacement pump, inserted in the LDPU, are the
materials the components can be made of.
COMPONENT USED MATERIALS

BEARING HOUSING CAST IRON GG25


GEAR COVER B1 B2 B3 B4 SERIES ALLOY
GEAR COVER B5 B6 SERIES CAST IRON GG25
PUMPING CASE AISI 316 L or in optional: HASTELLOY C276; TITANIO GRADO 5; DUPLEX SAF 2507
SHAFTS AISI 316 L or in optional: HASTELLOY C276; TITANIO GRADO 5; DUPLEX SAF 2507
ROTORS WITH STANDARD CLEARANCES AISI 316 L or in optional: HASTELLOY C276; TITANIO GRADO 5; lega antifrizione CY5SnBIM
ROTORS WITH INCREASED CLEARANCES AISI 316 L or in optional: HASTELLOY C276; TITANIO GRADO 5; lega antifrizione CY5SnBIM
RUBBER COATED ROTORS Anima in AISI 316 L + optional one of the following elastomers: N.B.R., E.P.D.M., °VITON (F.K.M.)

1.6 Occupied workplaces


The LDPU does not occupy any operator in a fixed manner. The operator occupies an occasional workplace and checks its proper operation as per the
inspection and checking activity of the productive line the LDPU is part of.

1.7 Indication of the safety systems


In order to reduce the risks associated with malfunctions or misuse, the LDPU is equipped with the following security systems that are able to prevent /
manage situations of danger for the operator:
• fixed joint transmission guards;
• emergency stop button;
• seal protections (excluding the LDPU version with flushed mechanical seals or double mechanical seals).
O.M.A.C. s.r.l.
Chap.1 - pag. 14 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

As an optional feature, the LDPU can come with the full fairing. Below there are the above mentioned safety systems.

1.7.1 Flexible transmission coupling protection


The flexible transmission coupling is protected by a removable mechanical transmission device, made up of an even coverage, accurately shaped and
made of AISI 304 or aluminium, which protects the operators from contact with the rotating parts.

DANGER
It is absolutely forbidden to operate the LDPU if the safety devices have been removed.

1.7.2 Emergency stop


The emergency stop is a safety system made up of a red button, in the shape of a mushroom, on a yellow background and fitted on the electric panel,
eventually supplied with the LDPU. These buttons, when present and pressed, block the work cycle of the LDPU, stopping every movement in a few
seconds: therefore they have no effect on stopping the work cycle of the plant the LDPU is connected to. Therefore, to stop the operation of the plant,
upstream and downstream from the pump, one must act on the plant emergency stop buttons.

DANGER
This emergency stop button IS NOT THE PLANT EMERGENCY STOP BUTTON.
To stop the operation of the plant, upstream and downstream from the pump, one must act on the plant emergency stop buttons.

The emergency stop button can only be used in situations of severe and immediate danger, which require the immediate stop of all parts. Once the button
has been pressed it will stay blocked until the operator performs its manual unblocking (by rotating it in the direction indicated by the arrow printed on the
control), thus maintaining the LDPU in a state of emergency.

DANGER
It is absolutely forbidden to operate the LDPU if the safety devices have been removed. Damaged safety devices must be replaced immediately. Never
neutralise the safety devices.

1.7.3 Seals protections


The seals protections, re. position 239, section 1.3, are laminations made of AISI 304 or resistant plastic and are applied with screws on the bearings box
to protect the operator from contact with the rotating parts of the pump: in particular they cover the rear area of the pump body where the seals supports
are fitted.

DANGER
It is absolutely forbidden to operate the LDPU if the safety devices have been removed.

1.7.4 Optional features: full fairing


The full fairing of the LDPU is made up of a cover made of AISI 304 shaped appropriately, according to the dimensions of the unit, and fully covers the
transmission parts during their operation, in order to protect the operators present on the plant layout, where possible, from the accidental contact with
the parts.

DANGER
It is absolutely forbidden to operate the LDPU if the safety devices have been removed.

1.7.5 Optional features: electric safety devices and pressure limiters


Upon specific request of the customer company it is possible to equip the LDPU with two kinds of safety systems:
• pressure;
• electrical;
In particular the electrician called by the customer to perform this connection and qualified for the job, must design and make the electrical connections
in compliance with the electrical regulations in force.
The electrician called by the customer to carry out the connections above must also envision a general reset function after the activation of the emergency
state.

DANGER
It is absolutely forbidden to perform maintenance or repairs interventions on the LDPU, without having worn the PPE.

DANGER
It is absolutely forbidden to operate the LDPU after the occurrence of faults or malfunctions of the pump or equipment or devices connected to it. Dama-
ged safety devices must be replaced immediately. Never neutralise the safety devices.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.1 - pag. 15
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

Never carry out any type of maintenance intervention directly, always contact the maintenance manager. Only this person is qualified to carry out main-
tenance operations professionally and in safety conditions. Before carrying out maintenance activities on the LDPU, ensure that there are no danger
situations and that the machine and plant it is connected to are in emergency stop conditions.

1.8 Noise and vibrations emitted


In the envisioned conditions and methods, the sound level test was carried out to define the noise value emitted by the LDPU. The sound level test of the
LDPU was performed using water as process fluid, and using the O.M.A.C. pumps testing plant.
The sound level values detected were determined applying standard EN12639 and adopting the measuring specifications of ISO 3746, and are the
following:
• Sound power level equivalent to 2 meters distance in work: 65 dB(A).

1.9 Use of the personal protection equipment


During the LDPU assembly and disassembly operations, as during its routine and extraordinary maintenance, one must wear the personal protection
equipment, according to the operation and risk connected to the activity performed by the appointed operator.

DANGER
It is absolutely forbidden to perform maintenance or repairs interventions on the LDPU, without having worn the PPE.
PPE RISK USE EXPOSED PERSONNEL
Shoes with reinforced toe Lower limbs crushing always maintenance operator / operator
caps and non-slip soles
Coated safety gloves cuts and abrasions to upper limbs during installation or use of the unit maintenance operator / operator

Safety goggles Dust during installation or use of the unit maintenance operator / operator

Filtering face mask exposure to chemical agents maintenance or cleaning maintenance operator
Neoprene safety gloves exposure to chemical agents maintenance or cleaning maintenance operator

Work clothes Dust, entangling always maintenance operator / operator


Ear plugs Noise use of the pump unit operator

ATTENTION
To prevent mechanical risks, such as dragging, entrapment and other, do not wear accessories such as bracelets, watches, wings or chains.

1.10 Personnel training


The LDPU is made in such a manner to enable use directly by qualified personnel, for this reason one does not envision training periods, however the
user, before performing any activities, must:
• carefully read this use and maintenance manual, paying attention to chapter 4, “Use of the machine”,
• supervise routine maintenance operations;
• supervise the proper use of the LDPU;
• check the protection devices work.

DANGER
Children, disabled persons, persons with by-passes or cardiac problems are not admitted as operators.

Therefore it is up to the customer to train the personnel appointed to use the machine, before it is commissioned.
The operator must have a technical professional qualification, as well as suitable knowledge of general safety standards.
During the training course, the training level of the operator must be supervised by the customer company, which has the technical and organisational
knowledge necessary to carry out such task.
As provided by the current regulatory framework on health and safety at work, the training process should be formalised directly by the customer.

1.11 B Series lobe positive displacement pump optional features


1.11.1 Pump in aseptic version
Excluding models B100, B660, B680, one can make the “B series lobe displacement pump” , part of the machine, in aseptic version (with steam or sterile
liquid barrier on the cover), on the mechanical seals and openings. The aseptic LDPU is used in transfer processes of alimentary or chemical fluids which
have undergone sterilisation and must not be contaminated in any way during transfer.
In the figures below there are the indications of inlet holes (A, C, E) and outlet holes (B, D, F) of the sterile liquid or steam inside the openings (A, B, E,
F) of the pumping body and the cover of the pump body (C, D). For the seals consult section 1.3.9.

O.M.A.C. s.r.l.
Chap.1 - pag. 16 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.11.2 Pump with widened rectangular inlet port


Models B115, B220, B330,B390, B440, B490 can be
made with a rectangular widened suction inlet to facilitate
supply of the “B series lobe displacement pump” with very
viscous products such as mixtures or thick mixtures with
semi-solid pieces.
In these cases to facilitate the product to fall in, the pump
is installed with openings in vertical axis directly under the
hopper.
To connect the bare shaft pumps with vertical axis piping
one must disassemble the foot of the pump (fixed for mo-
dels B100 - B550 - B6) and fix the gear box directly to the
special feet that can be supplied upon request (already
included in the “vertical base”). If the “B series lobe displa-
cement pump” is supplied bare shaft (without control unit),
check the proper position of the caps and oil level.

1.11.3 Pump with heating/cooling chamber on pumping case and front cover
In the event one wishes to maintain the pumped fluid at a
constant temperature one can apply a cavity on the pump
body and/or cover for heating / cooling liquid circulation
to all the pumps of the range (excluding B100). Typical
cases are the transfer of glucose, chocolate, melted fats,
butter, margarine, and others.
For the dimensions of holes and the circuit diagram, con-
sult the table in section 1.3.9.
The pipes and couplings for the circuit are not supplied
with the pump.

1.11.4 Pump with mechanical safety valve on front cover


One of the possible versions of the “B series lobe displa-
cement pump” envisions the possibility to fit a mechanical
safety valve
on the front cover, which intercepts and dampens any
pressure peaks over the limit for which the valve is set.
• The safety valve, fitted directly on the front co-
ver of the pump, is reversible and activated by a spring
compressed by a regulator;
• The setting of the safety valve must be car-
ried out on site by the Customer, because the entity of
the recycling depends on the pump speed, on the specific
weight and product viscosity.
• To prevent continuous vibrations, the safety
valve must be adjusted in such a way that it starts working
at a pressure 10% higher than the working pressure.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.1 - pag. 17
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

1.11.5 Pump with pneumatic safety valve on cover


One of the possible versions of the “B series lobe displacement pump” envisions the possi-
bility to fit a pneumatic safety valve on the front cover, which intercepts and dampens any
pressure peaks over the limit for which the valve is set. The valve is fitted on the cover and
is made up of a cylindrical casing in which a piston slides. The fluid pressure (FP) acts on
PP
the piston face, whilst the pressure of the pneumatic plant (PP) acts on a plate fixed to the
piston. FP
When the force that the air exercises on the plate is higher than that exercised by the li-
quid on the piston, the valves stays closed, otherwise the piston moves opening discharge PP
volumes in the pumping chamber, that enable pressure balancing. Calibrating the by-pass
means supplying the air chamber with a pressure value that keeps the valve closed until the
pressure limit value in the pump reaches the desired value.

1.11.6 Pump with external mechanical bridge safety valve


The external safety valve is made up of a spring valve positioned on a pipe bridge that
connects delivery and suction and can also be used as a by-pass to recycle all or part of the
pumped liquid. On this valve, the adjustment of the tightness pressure is up to a spring that
can be more or less compressed. The system composed in this manner is one-way so if one
inverts the direction of the pump, it is essential to invert the positioning of the valve as well
that, in any case, must always be on the delivery side.
One can choose various kinds of springs according to the working pressure. The adjustment
must be carried out manually on site
on the appropriate adjustment ring.

1.12 B Series LDPU optional features

1.12.1 Motorized B Series LDPU on fixed base


For customer needs, the motorised LDPU can be assembled on a base made of AISI 304 or
metal, to then be fixed, via bolts, to the floor.
The motorised LDPU on a fixed base is made up as follows:
• Support base made of press-moulded sheet metal;
• B series lobe displacement pump fixed to the base;
• Speed controller / gear motor / direct electric motor / hydraulic motor / pneumatic
motor fixed to the base;
• Flexible mechanical transmission coupling;
• Flexible mechanical transmission coupling protection;
• Seals protections (excluding the flushed mechanical or double mechanical
seals);
• Fairing (when envisioned in the pump Unit supply, in this special version the
mechanical transmission coupling protection is not installed).

1.12.2 Motorized B Series LDPU on trolley base


For customer needs, the motorised LDPU can be assembled on a base made of AISI 304 or
metal, equipped with polyamide
or pneumatic wheels and trolley transportation handle.
The motorised LDPU on a trolley base is made up as follows:
• Trolley for unit transportation;
• B series lobe displacement pump fixed to the trolley;
• Speed controller / gear motor / direct electric motor / hydraulic motor / pneumatic
motor fixed to the base.
• Flexible mechanical transmission coupling;
• Flexible mechanical transmission coupling protection;
• Seals protections (excluding the flushed mechanical or double mechanical
seals);
• Fairing (when envisioned in the pump Unit supply, in this special version the
mechanical transmission coupling protection is not installed);
• Electric control panel (not present in the version shown in the figure).
O.M.A.C. s.r.l.
Chap.1 - pag. 18 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 2: LDPU B SERIES TRANSPORTATION


In order to ensure safety of personnel involved and considering the peculiar features of the “B series lobe displacement Pump Unit”, this can be handled
only by personnel used to deal with heavy material and with the suitable hoisting equipment, complete with the relative hoisting accessories. For this
reason only these people can recognise and exclude dangers for third parties and/or for the handled material.
Below there is a table illustrating the mass of the various LDPU models.

LDPU B SERIES MODEL LDPU B SERIES WEIGHT (kg.) TYPE OF BELTS FOR LIFTING
B100 40
B105 B110 B115 80
B215 B220 130
B325 B330 B390 220
CHECK THE WEIGHT TO BE LIFTED
B430 B440 350
B470 B490 550
B550 700
B660 B680 1100

DANGER
The LDPU has dimensions and weights that change according to its version and size. Take great care when handling and transporting. In particular,
carefully follow all instructions for correct weight distribution.

ATTENTION
Pay utmost attention during the pump unpacking operations, described further on.

2.1 Hoisting and transportation


The “B series lobe displacement Pump Unit” is delivered to the customer inside a wooden crate (pack closed with screws; for further information please
refer to section 2.4 of this use and maintenance manual).
On the basis of the weight table indications, at the beginning of this chapter, crate handling can be carried out only with a forklift with suitable capacity,
supplied by the customer and driven by personnel appointed by the customer, with the requirements needed to perform all operations in safety conditions.
In addition the personnel must be used to handle delicate high-tech loads.

DANGER
It is absolutely forbidden to handle the LDPU without a forklift with suitable capacity and driven by a person authorised by the customer, with the appro-
priate legal requirements.

ATTENTION
The crate containing the LDPU will be hoisted exclusively with a forklift.
To handle the crate, proceed as follows:
• place the forks of the forklift in correspondence of the slits between the feet of the handled crate base; slowly position under the base of the
crate, ensuring that the centre-line of the forklift corresponds to the centre-line of the crate;
• hoist the LDPU carefully by about 50 millimetres, checking it is parallel compared to the lorry bed;
• reverse slowly, but evenly, until the whole crate is completely out of the way of the lorry bed;
• lower immediately (very slowly and avoiding sudden stops when lowering) until the forks of the forklift are about 50 millimetres from the
ground;
• proceeding very slowly and carefully, put it in position.

Once the crate has been handled, one must place it near the LDPU installation area, in order to reduce any risks deriving from the manual handling of
weights.

DANGER
During hoisting and transportation operate with great caution, in order to prevent damage to people or things.
O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.2 - pag. 1
Rev.4 del 01/2011 O.M.A.C. s.r.l.

DANGER
During hoisting and transportation ensure that there are no exposed persons in a dangerous area.

2.2 Delivery and unpacking


a. Delivery
All the material supplied to the customer is accurately checked by O.M.A.C. s.r.l. before shipment. Upon receipt of the LDPU ensure that the material
has not been damaged during transport and that the package has not been tampered with resulting in removal of parts from the inside. If one finds the
package is damaged, immediately notify the carrier and O.M.A.C. s.r.l. producing photographic documentation.

WARNING
With reference to the table at the beginning of this chapter, the weight of the LDPU can vary according to its version and dimensions of the products it is
made up of. The units must be handled using hoisting equipment, complete with the relative accessories.

b. Unpacking
Take utmost care during the unpacking operations of the LDPU and complete the following steps:
• Open the crate, using an electric screwdriver to remove the fixing screws of the crate lid;
• Carefully remove the packaging from the LDPU;
• Check is the LDPU has any visible signs of damage;
• Place the packaging in the warehouse;
• Ensure that there are the protective plastic caps closing the connections openings;
• Ensure that the equipment supplied with the LDPU is not damaged.

In the event there is damage or parts are missing, immediately notify the carrier and O.M.A.C. s.r.l. producing photographic documentation.
Unless otherwise indicated the LDPU is shipped fully assembled, protected by a nylon sheet and set in a wooden crate. Fixing is achieved with four wood
screws (see table in section 2.4); positioned in the appropriate pre-drilled holes on the LDPU support base. Should the user need to transport the LDPU
one must restore the conditions described above.

WARNING
Keep the LDPU packaging with care, during its entire operating period. The original packaging is needed for a possible transfer of the LDPU, after its
first installation.

2.3 Conditions for storage or extended interruptions of service


The LDPU has been designed for immediate use, however if the machine down time conditions should occur for long periods, one must:
• disconnect the LDPU from the electrical mains;
• following the instructions in this UMM, disconnect the LDPU from the plant it is connected to; close the suction inlets and delivery outlets with
the supplied closure plugs.
• with reference to chapter 5 remove the seals and see to cleaning and sanitising them;
• lubricate and clean the seals, the pump body and the parts contained;
• put the LDPU back in its original packaging, as instructed in section 2.4, covering the electric supply and control panels with particular care;
• place the LDPU on scaffolding with suitable capacity to support the weight of the LDPU, avoiding putting weights on top of the machine;
• store the LDPU in a dry place, in its original packaging, positioning it according to the instructions shown on the crate;
• store it at a room temperature above +5°C and below +30°C, and keep it in a sheltered place away from weather or other.

WARNING
Place the LDPU back on the scaffolding with suitable capacity to support the weight of the LDPU.

WARNING
In order to keep the features of the LDPU unvaried, one must comply with all the instructions above and it is recommended to avoid particularly damp
environments.

O.M.A.C. s.r.l.
Chap.2 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

2.4 Packaging composition for future handling


In the event of transferring the LDPU, after its first installation, one must use its original transportation crate.

ATTENTION
To transport the LDPU, use the original O.M.A.C. transportation crate.

Fix the LDPU with the appropriate fixing screws, to the wooden base, placing a nylon sheet between the wooden base and the unit.

ATTENTION
Place the nylon sheet between the wooden base and the LDPU, to protect the machine from dust.

Subsequently, fit the external panels and lid on the sides of the base, which will make up the transportation packaging of the LDPU.
Below in the figure there is a typical example of the LDPU packaging.
In cases where the legislation in force requires it, one must use wooden crates that have undergone fumigation treatment.

TYPICAL PACKAGING DELIVERED


LENGHT X WIDTH X HEIGHT
WEIGHT (kg)
of the CRATE(rif. dis. cassa Z x X x Y)
36 X 26 X 39 5
45 X 35 X 44 7
65 X 43 X 54 10
76 X 42 X 64 13
86 X 61 X 74 19
100 X 42 X 53 16
120 X 80 X 117 45
130 X 53 X 64 20
160 X 63 X 74 31
160 X 63 X 135 41
200 X 71 X 104 51
230 X 72 X 95 61

2.5 Handling of the B Series LDPU without packaging

ATTENTION
If the LDPU is equipped with the full fairing, before carrying out hoisting operations one must “disassemble” the fairing by unscrewing the hexagon screws
that fix it to the support base.

To handle and hoist the LDPU without packaging, it is recommended to use hoisting equipment, complete with the relative accessories, with minimum
capacity suitable for the machine to be hoisted (for weights consult the table below). Hoist and handle the pump Unit as indicated in the figure.
Only the B100 model LDPU can be handled and hoisted by hand as its maximum weight is 30 Kg. To carry out the mentioned operations use belts with
adequate capacity (not supplied).

DANGER
It is forbidden to use worn hoisting belts.

All LDPU handling operations must be carried out by personnel authorised by the customer. The authorised personnel must know how to use the hoisting
equipment. He must:
• use hoisting belts that are not worn;
• arrange and wrap the belt around the LDPU, as indicated in the figure on the following page;
• stretch the belts delicately;

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.2 - pag. 3
Rev.4 del 01/2011 O.M.A.C. s.r.l.

• ensure that the belts do not strain and that their position around
the LDPU does not move when hoisting; in the event there is a speed
controller fitted, make sure that the belts do not strain on the control hand-
wheel;
• hoist the LDPU from the ground by about 20 - 25 cm and move
it to installation place.
The position of the centre of mass is indicative because it depends on the
configuration of the LDPU.

The center of mass position is indicative and it depends by LDPU configuration. = center of mass

WARNING
IT IS ABSOLUTELY FORBIDDEN TO HOIST THE LDPU WITH METHODS OTHER THAN THOSE INDICATED.

NO!

O.M.A.C. s.r.l.
Chap.2 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 3: LDPU B SERIES INSTALLATION


Before carrying out any intervention on the LDPU, read and understand this chapter in full. The operators responsible for the assembly/installation acti-
vities must have good familiarity with this type of equipment and possess recognised technical skills acquired in at least three years of similar activities,
this experience is essential to limit and reduce the risks involved in assembly/installation activities.
Good knowledge of the systems and components of the LDPU is essential before carrying out any operation.

DANGER
Assembly and disassembly operations of the LDPU, performed incorrectly and / or differently from the instructions herein, could be extremely dangerous
and cause injuries.
Only use the tools and utensils listed in this manual; furthermore during assembly and disassembly operations one must wear personal protection equi-
pment, listed in section 1.9 of chapter 1.

3.1 Destination and intended environments


In order to ensure maintaining the hygienic levels required by the customer, one must install the LDPU in closed work environments, whose features
comply with the requirements of this manual; the floor must be level, made of concrete, without bumps and solid enough not to collapse.
In the event the LDPU is supplied for alimentary use, the work environment must meet specific hygiene regulations requirements.

ATTENTION
The “B series lobe displacement Pump Unit” must be installed in closed work environments, not exposed to weather.

ATTENTION
Installation of the LDPU for alimentary use and its place of use must comply with the hygienic and sanitary standards required by the legislation in
force.
In order to facilitate installation, use, sanitisation and maintenance of the LDPU, the Customer must prepare a space free from obstacles, with a free
area of at least 3m2.

ATTENTION
A work space below 3 m2 may lead to incorrect installation of the LDPU as well as non-functional nor easy maintenance

3.2 Condizioni ambientali


The “B series lobe displacement Pump Unit” gives maximum performance when used in work environments that meet the following work conditions:

RELATIVE HUMIDITY BELOW 50%


ROOM TEMPERATURE BETWEEN +5°C AND +40°C

ATTENTION
IT IS FORBIDDEN TO USE THE LDPU IN ENVIRONMENTAL CONDITIONS OTHER THAN THOSE INDICATED ABOVE.

ATTENTION
ONE PROHIBITS ALIMENTARY USE OF THE LDPU IN ENVIRONMENTS THAT DO NOT MEET THE HYGIENIC AND SANITARY STANDARDS RE-
QUIRED BY THE LEGISLATION IN FORCE.

3.2.1 Room lighting


The Customer must ensure suitable lighting of the work area, as required by EU Directives and the work legislation in force.
So not to cause reflections that can distract and dazzle workers or prevent, even partially, reading the control panels and signals, when provided by the
LDPU configuration, we recommend using a diffused light.

NOTE
For maintenance and repairs interventions on the machine it is recommended to use a portable battery torch, which can be orientated in the most appro-
priate direction depending on the kind of intervention.

3.3 Installation and assembly


The assembly and installation of the LDPU must be performed only by qualified personnel, authorised by the Customer in compliance with the standards
in force, as well as observing the instructions supplied below.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.3 - pag. 1
Rev.4 del 01/2011 O.M.A.C. s.r.l.

ATTENTION
Depending on its use, it is responsibility of the Customer to equip the installation room in order to comply with the safety and hygiene standards in
force.

To operate, the LDPU needs to be connected to some utilities, such as for example:
TYPE OF UTILITY USE
electrical panel and control panel (if present) + earthing
Company electrical system
electric motor (in absence of control panel)
Hydraulic unit optional features such as: hydraulic motor, seals flushing circuit
Pneumatic system optional features such as: operation of the pneumatic safety valve
Customer plant transfer of processed fluid
Sanitising steam system optional features such as: aseptic version

3.3.1 Notes for the installer


Before proceeding with the installation operations of the LDPU, the installer responsible for these operations must make sure that the plant of the Custo-
mer has previously been cleaned with a piping washing cycle. during this cycle, the suction connection inlet of the plant must be connected directly to the
delivery outlet of the plant, in order to carry out the preliminary washing and cleaning cycle.
This operation enables to eliminate all solid residues (dust, processing or welding scraps, etc.), produced during the pipes assembly stages, which may
lead to malfunctioning of the “B series lobe displacement Pump Unit”, such as possible rotor seizing.
Please note that the machine supplied by O.M.A.C. s.r.l. does not require preventive cleaning before use.

NOTE
The pipes cleaning and washing operation must be carried out whenever the Customer appoints the installer to perform changes on the plant, such as
inserting manometers on the line, fittings or other, in order to ensure the elimination of solid particles that would lead to malfunctioning of the LDPU. THE
LDPU MUST NOT UNDERGO THIS CLEANING CYCLE, MEANING THAT THE INSTALLER MUST CONNECT THE UNIT SUCTION PIPING DIRECTLY
TO THE DELIVERY PIPING, THUS EXCLUDING THE LOBE DISPLACEMENT PUMP.

In addition, before production it is essential to carry out cleaning activities, as described in section 3.4.

3.3.2 Preliminary checks


To start installation activities, one must carry out some preliminary checks, relating to the work environment (with reference to section 3.2) and to the
integrity of the product (with reference to section 2.2).
If this inspection should highlight the non compliance with the requirements, the Customer must:
• in the event of environment inadequacy, proceed to meet the requirements;
• if there is damage or non-compliance with the order, immediately notify O.M.A.C. s.r.l., producing photographic documentation;
• make sure that the utilities, listed above, are near the LDPU installation place and that they meet the requirements of section 1.3 and what is
contained in the technical sheet.

ATTENTION
Failure to comply with the indications of section 1.3 and the technical sheet, may lead to anomalous operation of the LDPU (excessive noise, vibrations,
etc...) or malfunctioning that can cause mechanical damages.
The Customer is responsible for the installation and proper operation of the LDPU as well as compliance with the indications of section 1.3 and the
technical sheet

• ensure one can connect the LDPU to a plant that meets at least the hygienic standard of the LDPU, as shown in the declaration of conformity
attached to this manual;
• ensure that the Customer plant is, from the dimensional point of view, satisfactory for the requirements of the LDPU (suction-delivery openings
dimensions, piping diameter, height from the ground, unit dimensions, adequate N.P.S.H. (Net Positive Suction Head) available, linear piping to prevent
back-flow, etc.)
• make sure that the paving or metallic structure on which the LDPU will be installed has a suitable capacity for supporting the weight of the
unit;
• make sure there is enough work space, free from obstacles, with a free area of at least 3 m2 that ensures the execution of all needed opera-
tions in complete safety conditions for the operator.

3.3.3 Installation
Below the are the activities that one must carry out, for safe and efficient installation. In particular, the instructions are divided in simple stages, as de-
scribed below:

O.M.A.C. s.r.l.
Chap.3 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

STAGE 1: PLACEMENT
Following the provisions of section 3.3.1 - Preliminary checks - and on the basis of the indications of chapter 2 of this use and maintenance manual, the
operators must see to harness and handle the LDPU to place it in the position required by the Customer and specified in the plant layout.
During this stage, one will need to use a forklift with suitable capacity, driven by personnel appointed by the Customer, as per chapter 2. One must pay
utmost attention in placing the LDPU in the envisioned position without intervening on the unit piping.
In the LDPU version with adjustable feet, the operators will see to measuring the height of the suction and delivery piping of the unit, after having positio-
ned the machine. Then they must adjust the height of the unit openings at the measured height, acting on the adjustable feet. Once the second operation
is complete, they can free the unit from the harnesses and proceed with stage 2 - fixing and installation, hooking the openings of the unit pumping part
by screwing them onto the plant piping.

ATTENTION
Check that there are the special non-slip rubber rings in the feet.

ATTENTION
Ensure the Customer plant is aligned properly with the suction
and delivery openings of the LDPU.

When installing the LDPU it is essential to leave a enough space for maintenance and possible removal.

During STAGE 1 relating to the POSITIONING it is recommended to avoid the followings situations:
WRONG!!!
• in the event there are horizontal AIR WRONG!!!
tracts of suction piping, make sure these are
AIR AIR
slightly inclined upwards to prevent air pockets
from forming which would inhibit perfect priming
of the LDPU;

• if the RIGHT!!! RIGHT!!! • if the LDPU is connected to a


LDPU is not un- vacuum tank, one must reduce the load
der the head, in leaks due to the suction piping as much
the suction tract as possible;
provide a foot or
check valve to
maintain priming; A = foot valve • install a check valve on the
or delivery tract to prevent the back-flow of
B = check valve air or liquid during interruptions of servi-
ce in order to maintain the pipes com-
• when applying in ver- WRONG!!! RIGHT!!!
pletely full and to facilitate starting when
tical position avoid connecting loaded.
the suction inlet to the lower side
DISCHARGE
and the delivery outlet to the
upper side. The proper configu-
ration consists in connecting the DISCHARGE
suction pipe to the upper side
and the delivery pipe to the lower
side. SUCTION SUCTION

STAGE 2: FIXING AND INSTALLATION ON SITE


Once the LDPU has been positioned and aligned to the Customer plant, proceed to fix and install in the plant. Since fixing between the plant and the
LDPU involves the suction inlet and delivery outlet of the pumping body, listed below are the maximum values of forces and moments, indicated with EF
and EM, which the pump body and consequently the LDPU, of which it is a part, can sustain, as maximum values, during standard operation.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.3 - pag. 3
Rev.4 del 01/2011 O.M.A.C. s.r.l.

FORCES [N] TORQUES [Nm]


PUMP TYPE
Fx Fy Fz EF Mx My Mz EM
B100 65 55 75 113 110 85 70 140
B105 B110 B115 105 95 120 186 125 100 90 164
B215 145 130 160 252 130 110 95 172
B220 190 180 220 342 140 115 100 183
B325 210 200 250 383 150 120 110 197
B330 B390 240 230 280 435 160 130 110 206
B430 B440 255 245 300 464 175 150 130 230
B470 B490 260 250 305 472 180 150 130 234
B550 340 340 355 598 190 160 150 255
B660 B680 405 405 440 722 200 180 170 276

STAGE 3: CONNECTION TO THE PLANT


The suction inlet and delivery outlet of the B series lobe displacement pumps, included in the LDPU, are sized for the passage of even very viscous
products, consequently the pipes do not necessarily need to be proportionate to them.
The suction and delivery pipes must be sized according to the calculations indicated in the O.M.A.C. technical manual, in relation to capacity, viscosity
and pressure loss that one wants to achieve.
Displacement pumps can operate with significant pressure losses in delivery, but not in suction where it is recommended to use pipes as large and short
as possible to maintain the NPSH required by the pump, part of the LDPU, lower than the NPSH available in the plant of the Customer.
The LDPU must always be installed as close as possible to the source from which it must suck up.

During STAGE 3 relating to the CONNECTION TO THE PLANT it is recommended to avoid the following situations:

• reduce the amount of bends and


narrowing as much as possible all along the
line;
(C) (D)
• using long range bends avoiding to
use “T” fittings and avoid unnecessary runs.
• check the complete air tightness of
the suction fittings in order not to decrease the
suction power of the pump. (A) (E)
• The weight of the piping must not
rest on the pump body and it must be con-
nected without using force to prevent overload (B)
and distortion of the pump body.
• In the case of very long piped, install a gate on the inlet and one on the outlet of the pump, to facilitate inspection without emptying the whole
unit uselessly.
• it is recommended to fit manometers and vacuum gauges as close as possible to the pump. They will be very useful to check the standard ope-
ration conditions of the pump and diagnose any inconveniences such as: pressure overloads, absence of fluid, work conditions instability, cavitation.
• protect the pump from hard solid bodies entering. Where possible install a suction filter: the filtering area must not be less than 4-5 times the
pipe section to minimise pressure losses.
• where possible, fit flexible expansion joints to reduce vibrations and prevent forcing due to thermal dilations of the pipes.

STAGE 4: FIXING THE LINE AND COMPLEMENTARY PROTECTIONS


The LDPU can be fixed in three ways, described below:

ATTENTION
If the LDPU has been supplied in the full fairing version and the fairing, or other parts of the unit, have been removed to facilitate on site positioning
operations of the LDPU, one must re-fit these parts on the LDPU before completing the fixing operations of the unit.

a) Fixing onto a metallic structure.


If one must fix the LDPU to a metallic structure, use the special pre-drilled holes on the support base. With ref. to the following drawings, for the distances
between the holes and the dimensions of bolted connections to use, see the table below, where for every kind of base size and its measurements “A” and
“B”, there are the sizes of the bolts for fixing to the metal structure:

O.M.A.C. s.r.l.
Chap.3 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

SUPPORT DOWEL
A B
SIZE SIZE
0 220 590 M12
1 220 590 M12
2 270 720 M12
3 330 920 M16
4 400 1100 M20
5 500 1400 M20
6 500 1400 M20
7 180 460 M10
8 450 1250 M20

ATTENTION
In the case the LDPU is installed at a height, one must provide a containment tank for any loss of fluid or lubricant liquid, due to malfunctioning.

b) Fixing on a concrete base.


If one needs to fix the “B series lobe displacement Pump Unit” on a concrete
base use the special pre-drilled holes on the support base. For the distance
between holes and the dowels to use, see the table below and the instruc-
tions supplied by the dowels manufacturer.

c) Support with adjustable feet


Upon explicit request of the user, the “B series lobe displacement Pump
Unit” can be supplied with four adjustable feet fixed to the support base.

ATTENTION
Check that there are the special non-slip rubber rings in the feet.

3.3.4 Accessories fitting


The LDPU can come with the following optional accessories:
a)mechanical safety valve on the cover of the pumping body (suitable for alimentary use);
b)pneumatic safety valve on the cover of the pumping body (suitable for alimentary use);
c)external bridge mechanical safety valve (suitable for alimentary use);
d)seals flushing circuit;
e)aseptic liquid circuit;
f)heating/cooling circuit on the cover of the pumping body or on the same pumping body.

When the LDPU is “for alimentary use” the assembly or replacement operations of the accessories, listed above, must mandatorily be followed by the
sanitisation procedures described in section 3.4 of this chapter, in order to restore the hygiene and safety level required (Lev. 1 of EN 14159).

These optional features must be order together with the LDPU becoming an integral part of it. Chapter 1 gives the technical specifications of the optional
features listed above, below there are the methods for adjusting or connecting the LDPU to the relative supply circuits. These operations must always be
carried out after installation (re. section 3.3.2) and therefore the indications below assume proper installation and connection to the energy sources.

ATTENTION
The adjustment of the mechanical and pneumatic safety valves, described below, must be carried out by the operator in charge, before commissioning
the LDPU.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.3 - pag. 5
Rev.4 del 01/2011 O.M.A.C. s.r.l.

A) MECHANICAL SAFETY VALVE AND ADJUSTMENT


The mechanical safety valve is made up of a cylindrical shaft in which a piston slides, on which a load spring is fitted.
The mechanical safety valve is fitted directly onto the front cover of the pump (pump body cover) and its purpose is to intercept pressure peaks of the
fluid in suction, allowing part of the processed fluid to recirculate in the pumping chamber.
The adjustment of the safety valve is achieved by adjusting compression of the spring (pos. 71) and on the adjustment screw (pos. 59). The adjustment
of the spring establishes the pressure value at which the mechanical safety valve opens and this adjustment must be carried out on site, as the recycle
entity depends on the pump speed, on the specific weight of the fluid, as well as its viscosity.
To prevent continuous vibrations, the safety valve must be adjusted in such a way that it starts working at a pressure 10% higher than the working
pressure.

ATTENTION
It is recommended to adjust the mechanical safety valve at an opening pressure 10% higher than the LDPU working pressure.

ATTENTION
The adjustment of the mechanical safety valve must be carried out on site by the Customer, since the recycle entity
depends on the LDPU speed, on the specific weight of the fluid, as well as its viscosity.

62
65
59
58
66
67
61
56
65 56/1
70
64 57
72
60
71

63

69

68
To adjust the mechanical safety valve one must follow the instructions below:
• Completely unscrew the adjustment screw (pos. 59) in order to disable the valve. 45
• Insert a thin rod in the inspection hole on the valve cover, pos. 58, until touching the ring.
• Start the LDPU with the safety valve spring loosened, i.e. not under pressure.
• Using a screwdriver gradually tighten the adjustment screw (pos. 59 in the figure to the right), compressing the spring and checking that the
pressure in the delivery outlet of the LDPU does not exceed the allowed pressure.

ATTENTION
With reference to section 3.3.3, in order to calibrate the spring there must be appropriate manometers on the suction and delivery pipes that indicate the
pressure in

• Tighten the adjustment screw until the thin rod starts to move.
• Compress the spring by 1/4 screw turn past the critical opening point to prevent vibrations.
• Position the regulator retainer (pos. 62 in the figure below) and block it with the appropriate hexagon hollow bolt (pos. 65 in the figure below).

The mechanical safety valve can also be used in manual mode, to adjust the capacity: unscrew the adjustment screw (pos. 59), release the spring
pressure until moving the piston away (pos. 57) from the pumping chamber, allowing part of the pumped liquid to return into the suction chamber. This
operation is not allowed for volatile fluids, such as for example solvents and fluids sensitive to temperature increase, due to continuous recirculation of
the same product. For products viscosity above 15000 cPs, if one must recycle all the pumped liquid it is recommended to install a by-pass on the line,
adequately proportionate, in order to allow the passage of the entire flow of the LDPU.

B) PNEUMATIC SAFETY VALVE AND ADJUSTMENT


The pneumatic safety valve is made up of a cylindrical shaft in which a piston slides and it is fitted directly onto the front cover of the pump (pump body
cover). Its purpose is to intercept pressure peaks of the fluid in suction, allowing a part of the processed fluid to recirculate in the pumping chamber. The
safety valve is in contact, on one side, with the processed fluid, whilst inside it is balanced with the pressure from the pneumatic circuit.

O.M.A.C. s.r.l.
Chap.3 - pag. 6 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

The adjustment of the pneumatic safety valve is carried out on site because it must be connected directly to the compressed air circuit on site. To adjust
it is recommended to use, as reference for the pressure and sizing of the compressed air unit, the graph below showing the correspondence between the
pressure inside the pump and the pressure in the valve. To prevent continuous vibrations, the safety valve must be adjusted in such a way that it starts
working at a pressure 10% higher than the working pressure.
When the force the pneumatic circuit exercises on the valve is higher than that exercised by the fluid, the valve stays closed; on the contrary the valve is
activated generating discharge volumes that enable balancing of forces, inside the pumping chamber.
by-pass pressure / B Series pump correspondence
91 95 98 97 101 107 104
72

93 102

103

by-pass pressure [bar]


96 106
109

94 108

105

92
100 99
B Series pump pressure [bar]
Before calibrating the pneumatic safety valve, one must calibrate the pneumatic circuit of the Customer, with a pressure value as follows:
• on the basis of the data carried in the LDPU technical sheet, detect the unit working pressure;
• with this data consult the graph shown on the next page to obtain the pressure value with which the safety valve must be calibrated.
Once one has obtained these values, proceed as indicated below:
• start the “B series lobe displacement Pump Unit” with the safety valve connected to the compressed air circuit;
• with reference to the indications on the manometer on the suction duct in proximity to the LDPU suction inlet, acting on the pneumatic pressure
regulator, manually increase or decrease the pressure value of the pneumatic circuit until reaching the critical balance value, i.e. the value obtained from
the graph.

To prevent continuous vibrations, the safety valve must be adjusted in such a way that it starts working at a pressure 10% higher than the working
pressure.

ATTENTION
The adjustment of the mechanical safety valve must be carried out on site by the Customer, since the recycle entity depends on the LDPU speed, on the
specific weight of the fluid, as well as its viscosity.

ATTENTION
The operations described herein require at least two manometers, for pressure values, installed on the suction and delivery pipes, near the LDPU ope-
nings that connect it to the plant of the Customer.

C) EXTERNAL BRIDGE MECHANICAL SAFETY VALVE AND ADJUSTMENT


The external mechanical safety valve is made up of a spring
valve positioned on a pipe bridge that connects delivery and
suction and can also be used as a by-pass to let all or part of the
processed fluid flow back.
To adjust the external bridge safety valve act on the spring
compression regulation, located on the upper part of the valve
body. The system composed in this manner is one-way so if one
SUCTION DISCHARGE
inverts the direction of the LDPU, it is essential to invert the po-
sitioning of the valve as well that, in any case, must always be
on the delivery side.
One can choose various kinds of springs according to the
working pressure. The adjustment must be carried out on site,
acting manually on the special adjustment ring. EXTERNAL BRIDGE
MECHANICAL SAFETY VALVE

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.3 - pag. 7
Rev.4 del 01/2011 O.M.A.C. s.r.l.

ATTENTION
The system composed in this manner is one-way so if one inverts the direction of the pump, it is essential to invert the positioning of the valve as well
that, in any case, must always be on the delivery side.

ATTENTION
The adjustment of the external bridge mechanical safety valve must be carried out on site by the Customer, since the recycle entity depends on the LDPU
speed, on the specific weight of the fluid, as well as its viscosity.

D) MECHANICAL SEALS FLUSHING CIRCUIT


The purpose of flushing mechanical seals is generally to cool down and lubricate the sliding faces of the mechanical seal, via forced circulation of a
flushing liquid.
The flushing liquid and its distribution circuit must be provided by the Customer. The Customer must also check, through his Technical
Office, the compatibility between the flushing liquid and the process fluid, as well as the compatibility between the
flushing liquid and the components of the “B series lobe displacement Pump Unit” in close contact (pumping cham-
ber material, seals material, working temperature, etc.)
Once this requirement has been checked and validated, the Technical Office of the Customer will see to expressly authorise the operator responsible for
the installation of the LDPU to fit the flushing circuit on the seals flushing chamber and commission it, before starting the LDPU for the first time

ATTENTION
The operator responsible for the flushing circuit must be expressly authorised by his Technical Office to connect the flushing circuit to a system that uses
“flushing liquid” compatible with the process fluid.
O.M.A.C. s.r.l. is not responsible for improper use of the flushing liquid nor for damages deriving from contamination of the process fluid.

DANGER
The improper use of the flushing system can cause breakage of mechanical seals resulting in damage to the LDPU
and contamination of the process fluid. O.M.A.C. s.r.l. is not responsible for improper use of the flushing system.

The operator designated by the Customer must connect the flushing circuit joints to the input and output holes of the seals flushing chambers and adjust
the temperature and pressure according to the type of seal fitted on the displacement pump, as described below:
• - in case of single mechanical seals the flushing pressure must be about 1.5 - 2 bar with 0.5 - 1 lt of flow-rate;
• - in the case of double mechanical seals the flushing pressure must be equal to the working pressure or higher by 1 bar, to ensure that the
film created between the sliding faces of the seals is made up of the flushing liquid and not by the process fluid, which according to its chemical compo-
sition may crystallise and solidify after machine down time and generate, upon restarting the unit, a “sticking” phenomenon of the faces, causing their
breakage.
The flushing temperature must be established according to the type of processed fluid and to the flushing utility: generally using liquid at room tempera-
ture - about 15° - 20° - is necessary to disperse the heat generated by friction of the seals faces, or vice-versa, using liquid at higher temperatures, for
example 80° - 90°, can be useful for melting, removing, cleaning and lubricating the seals faces.
The dimensions of the inlet and outlet holes joints of the flushing circuit are listed in the table in section 1.3.9 in chapter 1.
Below there is an illustration of the two kinds of flushing:

flushing diagram for low pressure seals flushing diagram for double seals with circuit under pressure

E) ASEPTIC LIQUID CIRCUIT


The aseptic liquid circuit (water steam), connected to the components of the LDPU which will come into contact with the process fluid (pump body, unit
connection openings, sealing parts) are used to ensure the product is aseptic, during its transfer cycle performed by the LDPU, from its suction inlet to
its delivery outlet.

O.M.A.C. s.r.l.
Chap.3 - pag. 8 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

If the displacement pump, part of


the LDPU, is supplied in “aseptic”
version, i.e. with front cover and
suction and delivery connection
openings equipped with internal
duct for steam barrier, the Cu-
stomer must connect the water
steam source and relative delive-
ry to the joints of the
aforementioned circuit, to make the components of the lobe displacement pump aseptic.
This necessitates the presence of a steam circuit inside the plant of the Customer.
The dimensions of the inlet and outlet holes joints of the aseptic circuit are listed in the table in section 1.3.9 in chapter 1.

F) COVER AND PUMPING CHAMBER HEATING/COOLING CIRCUIT


The heating / cooling circuit must be connected to the auxiliary circuit of the plant in which the LDPU
is located and must be commissioned by the designated operator before starting the plant concerned
by the process fluid, in order to adapt (raise, if the intent is to heat or lower, if the intent is to cool
down) the temperature of the components of the B series lobe displacement pump, affected by con-
tact with the process fluid at the temperature of the same process fluid.
The dimensions of the inlet and outlet holes joints of the heating / cooling circuit of the cover and
pumping chamber are listed in the table in section 1.3.9 in chapter 1.

3.4 Cleaning and hygiene of the LDPU


Listed below are the methods for cleaning the LDPU according to its operation environment: alimentary with hygiene level 1 or chemical.

ATTENTION
The Customer must also check, through his Technical Office, the compatibility between the C.I.P. liquid and the com-
ponents of the “B series lobe displacement Pump Unit” in close contact (pumping chamber material, seals material,
working temperature, etc.)

3.4.1 LDPU for alimentary use


To ensure hygiene and healthiness of the processed alimentary fluid, installation and start-up of the “B series lobe displacement Pump Unit” requires
preventive cleaning and sanitisation activities, these activities must take into account the particular features of the processed alimentary fluid, as well
as reaction times defined by the manufacturer of the detergent and sanitising product used and mentioned in the technical sheet. For this reason the
cleaning and sanitisation activities described in this section must be carried out in each of the following situations:
• after the installation of the LDPU;
• after a long down time of the LDPU;
• before every change of processed alimentary fluid;
• at the end of a work shift;
• when otherwise required by the characteristics of perishable processed alimentary fluid (short machine down times, changes in temperature,
etc ....);
• after routine/extraordinary maintenance.
• Once it has been installed in the plant of the Customer, the LDPU becomes an integral part both of the process unit and of the scheduled
cleaning system. In any case, as required by UNI EN standards for cleaning / sanitising this product, the level of hygiene of the LDPU can be identified
as LEVEL 1, so the activities described below are conducted to restore the same level of hygiene.
Generally the products used for cleaning and sanitising are of the following types:
• descaling detergents (cleaning of surfaces in contact with alimentary fluid after a long machine down time);
• degreasing detergents (external cleaning, cleaning of surfaces in contact with alimentary fluid);
• sodium hypochlorite based detergents in aqueous solution (5%) (sanitisation of surfaces in contact with alimentary fluid after a long machine
down time);
• detergents with quaternary ammonium salts in aqueous solution (5%) (sanitisation of surfaces in contact with alimentary fluid after a long
machine down time);
• please note that the LDPU requires cleaning and sanitising after a long machine down time or routine/extraordinary maintenance, one must
precede these activities by washing with a descaler, to be left to act according to the times indicated by the manufacturer.
Cleaning activities must be carried out by the operators in charge of running the plant in which the LDPU is integrated, therefore they must be read,
understood and carried out carefully by these operators.
Cleaning activities, if manual, must be carried out with the plant switched off and insulated from its energy sources.

ATTENTION
Cleaning activities must be carried out by the operators in charge of running the plant, therefore they must be read, understood and carried out carefully
by these operators.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.3 - pag. 9
Rev.4 del 01/2011 O.M.A.C. s.r.l.

ATTENTION
The hygiene level of the LDPU can be identified as LEVEL 1, according to UNI/EN standards, therefore the activities described below are carried out in
order to restore
the same hygiene level.
Cleaning and sanitising activities that concern the “B series lobe displacement Pump Unit” are divided according to two different contexts:
• external: DO NOT affect surfaces in contact with alimentary fluid;
• internal: affect surfaces in contact with alimentary fluid.
Below are the descriptions of the cleaning and sanitisation methods mentioned above.
3.4.1.1 External cleaning instructions
These cleaning activities are carried out manually, using the instruments needed to enact them, provided by the Customer and indicated below:

• pressure washer connected to waterworks under pressure;


• NON aggressive detergent with degreasing surfactants;
• wear the P.P.E. already provided by the Customer and Manufacturer of the plant in which the LDPU becomes an integral part, PPE that must
take into account what is indicated in the safety sheet of the detergent used.

After having put the detergent in the pressure washer and before going any further, cover the electric control panel, the electric motor and machine wiring,
paying particular attention to the cables input into the shunt/connection boxes, with nylon sheets, fastened securely.
Paying attention to NOT direct the water jet onto parts covered with nylon sheets and indicated above, switch on the pressure washer and proceed with
the cleaning the LDPU, orientating the water jet under pressure only towards the external surfaces of the pump, part of the LDPU, as well as the fixing
base on which the pump is fixed.

ATTENTION
DO NOT direct the jet onto parts covered with the nylon sheets such as: electric control panel, electric motor and wiring in the machine. Pay utmost
attention to NOT wet the cables input into the shunt/connection boxes.

If required by the manufacturer of the detergent used and if specified on the relative information sheet, rinse using cold water only.

3.4.1.2 Internal cleaning instructions


The cleaning and sanitisation activities of the surfaces in contact with alimentary products develops according to the following diagram, following the
indicated frequency:
WASHING DETERGENT
WHEN TO USE PERIODICITY
STAGES AGENT
STAGE 1 DESCALING FOLLOWING LONG MACHINE DOWN TIME EVERY 3 MONTHS
TO REMOVE RESIDUES OF PROCESS FLUID
STAGE 2 DEGREASING ALWAYS
IN CONTACT WITH THE PROCESS FLUID
SODIUM HYPOCHLORITE
STAGE 3 AFTER STAGE 2, TO SANITISE SURFACES ALWAYS
BASE
STAGE 4 WATER TO ELIMINATE RESIDUES OF DETERGENT ALWAYS
TO STERILISE THE COMPONENTS
STAGE 5 STEAM ALWAYS
IN CONTACT WITH THE PROCESS FLUID

Cleaning the surfaces in contact with the transferred process fluid articulates further into two different methods, as shown below:
• CIP/SIP;
• manual cleaning.
Below the two methods are explained better. -;

3.4.1.2.1 Internal cleaning: CIP (Cleaning In Place)/SIP (Sterilising In Place)


As well known, the CIP/SIP is a cleaning method of the entire plant that does NOT require the disassembly of parts and/or accessories inside the same
plant. The CIP/SIP is therefore a cleaning and sanitisation activity of the plant of which the LDPU is an integral part and therefore in turn affected by it.

ATTENTION
Before carrying out CIP/SIP one must perform each of the operations described below.

If the LDPU has been supplied with one or more accessories listed in section 3.3.3. of this UMM, before starting CIP/SIP, check the following:
• adjust the pressure of the safety valves (re. section 3.3.3 letters a,b,c) at a pressure value below the maximum pressure of the same CIP/SIP,
thus ensuring opening of the valve when washing the plant;
• ensure that the auxiliary units (flushing unit, cover heating and aseptic circuit), if present, are connected to the pump and work;
• if the customer envisions the LDPU to actively participate in the CIP/SIP, activate operation of the same LDPU.

O.M.A.C. s.r.l.
Chap.3 - pag. 10 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

On the basis of the indications given by the plant manufacturer, activate the CIP/SIP.
The duration of CIP/SIP depends on the type of process fluids treated. In order to ensure sanitisation of the LDPU, O.M.A.C. s.r.l. recommends the
CIP/SIP to last at least 1 hour.

ATTENTION
At the end of the CIP/SIP, but before restarting the plant, the safety valves must be re-set at the working pressure value, this activity must follow what is
indicated in section 3.3.3 of this manual.

3.4.1.2.2 Internal cleaning: manual cleaning


Manual cleaning activities must be carried out with the plant switched off and insulated from its energy sources; in addition the operator must wear P.P.E.
as indicated in chapter 1, section 9.
Manual cleaning activities entail:
a) disassembly of mechanical elements;
b) treated alimentary process fluids removal/extraction operations;
c) washing and sanitisation activities;
d) rinsing;
e) sterilisation;
f) reassembly of the previously removed mechanical elements.
Wear the P.P.E. as per Chapter 1, Section 9, paying attention to identify, on the basis of the thermal features of the treated process fluids, the gloves to
wear;

ATTENTION
Cleaning activities must be carried out by the operators in charge of running the plant, therefore they must be read, understood and carried out carefully
by these operators.

DANGER
Cleaning and sanitisation activities must be carried out with the plant switched off and insulated from its energy sources: electrical, pneumatic, hydraulic.
The operator in charge of this activity is obliged to wear the P.P.E. indicated in chapter 1, section 9, in order to ensure their safety.

a) The disassembly activities refer to the following mechanical elements:


• front cover;
• rotor blocking nuts;
• rotors;
• gaskets;
• any optional features (mechanical or pneumatic safety valve).
These elements must be disassembled following the indications contained in chapter 5, section 5.8, 5.9, 5.10 of this manual.

ATTENTION
During disassembly and assembly operations of the components listed under letter a), strictly follow the indications in sections 5.8, 5.9. 5.10.

b) The alimentary process fluids removal activities consist in manually removing most of the fluid present and seeing to its disposal.

c) Washing and sanitisation activities concern the previously disassembled single components, as well as the pumping chamber. Using a water and
degreasing detergent solution, wash the single components and the pumping chamber, paying particular attention to the seals area and shafts threaded
area.

d) Wash with plenty of aqueous solution until the visible process alimentary fluid is completely removed.

Once the alimentary process fluid has been removed from the contact surfaces, sanitise all the components that come into contact with the fluid. To do
this:
• prepare aqueous solution of sodium hypochlorite (5%);
• sanitise all surfaces in contact with the alimentary process fluid carrying out the operation for at least 15 minutes

ATTENTION
Sanitise all surfaces in contact with the alimentary product proceeding for at least 15 minutes
• with cold running water, rinse all the previously sanitised surfaces, making sure all traces of sanitiser are removed.

e) Sterilise the previously sanitised surfaces with water steam.

f) Reassemble the previously removed mechanical elements following the indications contained in Chapter 5, section 5.8, 5.9, 5.10 of this UMM.
After having assembled the clean and sanitised pump components, remove the protective sheets, placed on the electric panel, electric motor and cable
shunt/connection boxes and subsequently connect to the energy sources, disconnected before starting manual cleaning.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.3 - pag. 11
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

3.4.2 LDPU for chemical use


To ensure cleaning the process chemical fluid, LDPU installation and starting requires prior cleaning activity.
The cleaning activities described herein must be carried out in each of the following situations:
• after the installation of the LDPU;
• after a long down time of the LDPU;
• before every change of processed chemical fluid;
• at the end of a work shift;
• when otherwise required by the characteristics of perishable processed chemical fluid (short machine down times, changes in temperature, etc ....);
• after routine/extraordinary maintenance.
Once it has been installed in the plant of the Customer, the LDPU becomes an integral part both of the process unit and of the scheduled cleaning system.
Generally the products used for cleaning are of the following types:
• descaling detergents (cleaning of surfaces in contact with alimentary fluid after a long machine down time);
• degreasing detergents (external cleaning, cleaning of surfaces in contact with chemical fluid);
• sodium hypochlorite based detergents in aqueous solution (5%) (sanitisation of surfaces in contact with chemical fluid after a long machine down time);
• detergents with quaternary ammonium salts in aqueous solution (5%) (sanitisation of surfaces in contact with chemical fluid after a long ma-
chine down time);
• please note that the LDPU requires cleaning and sanitising after a long machine down time or routine/extraordinary maintenance, one must
precede these activities by washing with a descaler, to be left to act according to the times indicated by the manufacturer.
Cleaning activities must be carried out by the operators in charge of running the plant in which the LDPU is integrated, therefore they must be read,
understood and carried out carefully by these operators.
Cleaning activities, if manual, must be carried out with the plant switched off and insulated from its energy sources.

ATTENTION
Cleaning activities must be carried out by the operators in charge of running the plant, therefore they must be read, understood and carried out carefully
by these operators.
The cleaning activities that concern the LDPU are divided according to two different contexts:
• external: DO NOT affect surfaces in contact with chemical fluid;
• internal: affect surfaces in contact with chemical fluid.
Below are the descriptions of the cleaning methods mentioned above.

3.4.2.1 External cleaning instructions


The activities described herein must be carried out with the unit switched off and insulated from its energy sources and are intended to be performed by
the operators responsible for running the plant of which the LDPU is an integral part, therefore they must be read, understood and performed carefully
by these operators.
These cleaning activities are carried out manually, using the instruments needed to enact them, provided by the Customer and indicated below:
• pressure washer connected to waterworks under pressure;
• NON aggressive detergent with degreasing surfactants;
• wear the P.P.E. already provided by the Customer and Manufacturer of the plant in which the LDPU becomes an integral part, PPE that must
take into account what is indicated in the safety sheet of the detergent used.
After having put the detergent in the pressure washer and before going any further, cover the electric control panel, the electric motor and machine wiring,
paying particular attention to the cables input into the shunt/connection boxes, with nylon sheets, fastened securely.
Paying attention to NOT direct the water jet onto parts covered with nylon sheets and indicated above, switch on the pressure washer and proceed with
the cleaning the LDPU, orientating the water jet under pressure only towards the external surfaces of the pump, part of the LDPU, as well as the fixing
base on which the pump is fixed.

ATTENTION
DO NOT direct the jet onto parts covered with the nylon sheets such as: electric control panel, electric motor and wiring in the machine.
Pay utmost attention to NOT wet the cables input into the shunt/connection boxes.

3.4.2.2 Internal cleaning instructions


The cleaning and sanitisation activities of the surfaces in contact with alimentary products develops according to the following diagram, following the
indicated frequency:
WASHING DETERGENT
WHEN TO USE PERIODICITY
STAGES AGENT
STAGE 1 DESCALING FOLLOWING LONG MACHINE DOWN TIME EVERY 3 MONTHS
TO REMOVE RESIDUES OF PROCESS FLUID
STAGE 2 DEGREASING ALWAYS
IN CONTACT WITH THE PROCESS FLUID
SODIUM HYPOCHLORITE
STAGE 3 AFTER STAGE 2, TO SANITISE SURFACES ALWAYS
BASE
STAGE 4 WATER TO ELIMINATE RESIDUES OF DETERGENT ALWAYS

Cleaning the surfaces in contact with the transferred process fluid articulates further into two different methods, as shown below:

O.M.A.C. s.r.l.
Chap.3 - pag. 12 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

• CIP;
• manual cleaning.
Below the two methods are explained better.

3.4.2.2.1 Internal cleaning: CIP


As well known, the CIP/SIP is a cleaning method of the entire plant that does NOT require the disassembly of parts and/or accessories inside the same
plant. The CIP is therefore a cleaning activity of the plant of which the LDPU is an integral part and therefore in turn affected by it.

ATTENTION
Before carrying out CIP one must perform each of the operations described below.
If the LDPU has been supplied with one or more accessories listed in section 3.3.3 of this UMM, before starting CIP, check the following:
• adjust the pressure of the safety valves (re. section 3.3.3 letters a,b,c) at a pressure value below the maximum pressure of the same CIP, thus
ensuring opening of the valve when washing the plant;
• ensure that the auxiliary units (flushing unit, cover heating and aseptic circuit), if present, are connected to the pump and work;
• if the customer envisions the LDPU to actively participate in the CIP, activate operation of the same LDPU.

On the basis of the indications given by the plant manufacturer, activate the CIP.
The duration of CIP depends on the type of process fluids treated. In order to ensure sanitisation of the LDPU, O.M.A.C. s.r.l. recommends the CIP to
last at least 1 hour.

ATTENTION
At the end of the CIP, but before restarting the plant, the safety valves must be re-set at the working pressure value, this activity must follow what is
indicated in section 3.3.3 of this manual.

3.4.2.2.2 Internal cleaning: manual cleaning


Manual cleaning activities must be carried out with the plant switched off and insulated from its energy sources; in addition the operator must wear P.P.E.
as indicated in chapter 1, section 9. Manual cleaning activities entail:
a) disassembly of mechanical elements;
b) chemical process fluid removal/extraction operations;
c) washing and sanitisation activities;
d) rinsing;
e) reassembly of the previously removed mechanical elements.
Wear the P.P.E. as per Section 1.9 of Chapter 1, paying attention to identify, on the basis of the thermal features of the process fluids, the gloves to
wear;

ATTENTION
Cleaning activities must be carried out by the operators in charge of running the plant, therefore they must be read, understood and carried out carefully
by these operators.

DANGER
Manual cleaning activities must be carried out with the plant switched off and insulated from its energy sources: electrical, pneumatic, hydraulic. The
operator in charge of this activity is obliged to wear the P.P.E. indicated in chapter 1, section 9, in order to ensure their safety.

a) The disassembly activities refer to the following mechanical elements:


• front cover;
• rotor blocking nuts;
• rotors;
• gaskets;
• any optional features (mechanical or pneumatic safety valve).
These elements must be disassembled following the indications contained in chapter 5, section 5.8, 5.9, 5.10 of this manual.

ATTENTION
During disassembly and assembly operations of the components listed under letter a), strictly follow the indications in sections 5.8, 5.9. 5.10.
b) The chemical process fluids removal activities consist in manually removing most of the fluid present and seeing to its disposal.
c) Washing and sanitisation activities concern the previously disassembled single components, as well as the pumping chamber. Using a water and
degreasing detergent solution, wash the single components and the pumping chamber, paying particular attention to the seals area and shafts threaded
area.
d) Wash with plenty of aqueous solution until the visible process chemical fluid is completely removed.

Once the chemical process fluid has been removed from the contact surfaces, clean all the components that come into contact with the fluid.
To do this:

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.3 - pag. 13
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

• prepare aqueous solution of sodium hypochlorite (5%);


• clean all surfaces in contact with the chemical process fluid carrying out the operation for at least 15 minutes;

ATTENTION
Sanitise all surfaces in contact with the chemical product proceeding for at least 15 minutes.
• with cold running water, rinse all the previously cleaned surfaces, making sure all traces of sanitiser are removed.
e) Reassemble the previously removed mechanical elements following the indications contained in Chapter 5, section 5.8, 5.9, 5.10 of this UMM. After
having assembled the clean pump components, remove the protective sheets, placed on the electric panel, electric motor and cable shunt/connection
boxes and subsequently connect to the energy sources, disconnected before starting manual cleaning.

3.5 Connection to energy sources


Below there are the procedures for connecting the LDPU to the energy sources, needed for its proper operation.

3.5.1 Connection to the electrical system


Connection to the electrical mains must be carried out by the operator responsible for the assembly/installation activities, in compliance with the strictest
technical standards, the connection must be carried out after the hydraulic connection. This personnel must have full knowledge of the rules for use and
operation of electrical equipment supplied with the LDPU.
The Customer must organise the plant layout so as to provide:
• a manual supply sectioning device,
• over-current and overload protection,
• devices that prevent spontaneous restarting.
Before carrying out the connection one must ensure that:
• the frequency and voltage of the Customer plant corresponds to the data carried in the “technical sheet” of the LDPU;
• The material used for the electrical connection has an IP degree suitable for the environment in which it is installed, in order to prevent the
conductors from overheating.
The connection of cables to the terminal board can be carried out both in triangle or star, complying with the data carried on the motor nameplate accor-
ding to the mains voltage.
The connection of electric wiring can take place as follows:
1) LDPU with electric panel;
2) LDPU without electric panel;
In particular, in case 1), in presence of the electric panel, the operator must carry out the following operations:
• section the electric mains in order to insulate the sockets from the industrial electricity supply;
• connect the plug;
• power the electricity sockets;
this way even the LDPU electric control panel is powered.

ATTENTION
Operate with caution: the LDPU and the control actuators are powered electrically.

In case 2), in absence of the electric panel, the operator must see to power the electric motor on the basis of the indication contained in the electric motor
Use and Maintenance Manual (UMM available in electronic version on the Internet websites of the relative manufacturers).
One must also provide earthing for the motor, using the jack provided on the motor and an adequate section conductor: the connection must be carried
out with a type NO7Vk mm2 35 section stranded wire with yellow-green insulation and crimped wire heads.

ATTENTION
Before carrying out any operation, check that the features of the distribution network (voltage and frequency) correspond to the data on the motor plate
or electric panel.

ATTENTION
O.M.A.C. s.r.l. is NOT responsible for damages caused by incorrect installation of the electric energy supply, in case of failure to comply with the technical
standards in force.

3.5.2 Connection to the hydraulic system


Before going further one must check compliance with the indications of section 3.3.2 of this chapter.
If the indications above have been observed, one can proceed with the following activities:
a) connection of mechanical seals flushing;
b) connection of pumping chamber cover heating/cooling;
c) connection of pumping body heating/cooling.

ATTENTION
It is essential, as indicated in section 3.3.1, before carrying out the hydraulic connections, to wash the plant - in order to clean the pump -, and the hydrau-
lic connection lines, from dirt residues such as dust, sand, process scraps, etc.
O.M.A.C. s.r.l.
Chap.3 - pag. 14 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

a) with reference to the drawing to the side and the dimensions of the threaded joints, shown in the table in section 1.3.9, identify the flushing connection
points on the LDPU as well as the types of fittings to use.

flushing method with “disposable” fluid flushing method with fluid recycle

b) connection of pumping
chamber cover heating/ c) connection of pumping
cooling; body heating/cooling;

ATTENTION
The Customer, on the basis of the table in section 1.3.9 must identify the proper kind of fittings to be used to connect the hydraulic unit. Any errors can
generate leaks of flushing/cooling/heating fluid not attributable to O.M.A.C. s.r.l.

To start assembly activities, the pipes used to compose the flushing/cooling/heating circuit must have fittings free to rotate at their ends in order to screw
onto the flushing chamber and cooling/heating chambers.

ATTENTION
Check that the ends of the fittings are free to rotate. If they are fixed to the pipe it will no longer be possible to screw them on and one must provide new
pipes of the same kind.

On the basis of the diagrams above, proceed with assembly, taking care to tighten the fittings.
Switch on the flushing unit and the cooling / heating unit that belong to the Customer in order to check there are no leaks of fluid, i.e. check the operations
above have been carried out properly.

ATTENTION
The Customer must ensure that the flushing unit is always started before starting the “B series lobe displacement Pump Unit”.
In case of brief or extended machine down times during the production period, in which the process fluid remains in contact with the internal parts of the
pumping body (e.g. transfers of vinyl glue in industrial use), the flushing unit must remain in constant operation, to not jeopardise the operation of the
pumping body sealing parts.

If one should find leaks, switch off the flushing unit and repeat the operations described above.

3.5.3 Connection to the pneumatic system


Connection to the pneumatic system assumes that the Customer provides connection to a pneumatic lubricated compressed air unit: the capacity and
pressure (bar) values of this unit are indicated in the attached technical sheet.

ATTENTION
The technical sheet carries the pressure and capacity values the LDPU needs to operate properly.

ATTENTION
Before going any further, ensure to comply with the indications of section 3.3.1 of this chapter.

In order to connect the LDPU to the pneumatic distribution network in safety conditions, observe and perform the following operations in sequence:
• close the valve the LDPU will be connected to;
• connect the light blue pipes with threaded fittings to the compressed air distribution unit;
• close the connection between the pipe and unit securely;
• connect the light blue pipes with the threaded fittings to the LDPU;
• close the connection between the pipe and the LDPU securely;

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.3 - pag. 15
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

• open the general valve and check the connection has been carried out properly.

3.6 Use of lubricants


The LDPU is delivered to the Customer complete with lubricant oil as per section 1.3.12. This oil is contained in the bearings box and is essential for
the lubrication of bearings and motion transmission gears. Please note that the LDPU has other mechanical elements that during maintenance require
lubrication. In chapter 5 there is further information regarding these operations.

3.7 Installation and pre-start check: operation test


After installation and connection to the energy sources, but before starting production, one must check the rotors rotate properly inside the pumping body,
compared to the flow direction of the fluid to be handled. To do this one must:
• check all earthing connections of the LDPU have been carried out;
• power the LDPU electrically;
• open the suction valve of the Customer plant;
• open the delivery valve of the Customer plant;
• wait for a few seconds (about 15 seconds) so that the fluid fills the pumping chamber;
• move the selector from position 0, off, to position 1, on (the on warning light will light up);
• press the START button;
• with the LDPU on, check that on the manometer on the delivery pipe there is pressure inside the same pipe;
• stop the LDPU by pressing the STOP button on the electric panel supplied with the machine or in the plant of the Customer.

O.M.A.C. s.r.l.
Chap.3 - pag. 16 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 4: USE OF THE B SERIES LDPU

The LDPU is intended to be used by operators in charge of running it; therefore:


• the operators in charge of using the LDPU must have good familiarity with this type of equipment and possess recognised technical skills
acquired in at least three years of similar activities;
• the operator in charge of running the unit is directly and formally named by the Customer company management;
• the instruction described in this chapter and relative to the LDPU must be read, understood and carried out carefully by these operators in charge.

ATTENTION
Knowledge of the following instructions and the experience of the operator in charge of running the plant of the customer are essential in order to limit
and reduce the risks associated with using the same production line.

4.1 Intended use


The LDPU, marketed by O.M.A.C. s.r.l., has been designed and made to be assembled in industrial plants owned by third parties, to transfer volumes of
fluids, compatible with the materials used during the construction of this machine: section 1.4.1 lists the recommended operational features of the LDPU,
depending on the processed fluid.
The LDPU requires compliance with all technical indications in this use and maintenance manual, which in this documentation will be indicated with the
abbreviation UMM, for its proper installation.
In general, the processed fluids must meet the following specifications:
Fluid properties and range of use:
1)TEMPERATURE: from -35°C to +180°C
2) VISCOSITY: Maximum 200’000cPs with forced feeding
3) HARD PARTICLE SIZE: Maximum 80% of clearance between rotors (see sect. 1.3.4)
The LDPU has been designed and made for two types of use:
• alimentary use;
• chemical use.

WARNING
The LDPU, for alimentary use, has been made to ensure a hygienic standard equal to LEVEL 1, on the basis of UNI EN 13951.

The LDPU for alimentary use and for chemical use has been designed to transfer volumes of fluids without altering the organoleptic properties nor the
physical properties.

WARNING
During its normal use, the LDPU for alimentary use and for chemical use does not alter the organoleptic characteristics nor the physical characteristics
of the processed fluid.

Every LDPU comes with a technical sheet indicating the operational features in relation to the processed fluid that must be handled (name of the fluid,
viscosity range, capacity range, speed range, temperature range), as declared at the time of purchase by the Customer. Section 1.3 shows a facsimile of
the LDPU technical sheet. Every modification to what is indicated in the specific technical sheet or variation of the machine operating parameters must
be authorised in writing by O.M.A.C. s.r.l.; the absence of such authorisation is deemed “improper use” and will void any warranty or liability under way
between Manufacturer and Customer.

DANGER
Any use of the LDPU in conditions other than those indicated in “Fluid properties and range of use” and in conditions other than those indicated in the
machine technical sheet is forbidden, without explicit written authorisation, issued by O.M.A.C. s.r.l.

The LDPU for alimentary use and for chemical use has NOT been designed nor built to handle pharmaceutical, explosive, etc. fluids, and in general
fluids that do not comply with the indications of the specific technical sheet. In addition, the LDPU for alimentary use and chemical use has NOT been
designed nor built to handle what is indicated in Regulation (EC) No. 1005/2009 of the European Parliament and the Council of 16 September, 2009, on
substances that deplete the ozone layer.

ATTENTION
It is forbidden to use the LDPU for alimentary use and for chemical use to transfer the substances listed in Annex I of Regulation No. 1005/2009.

The pumping part of the LDPU is made up of the pump body, in which two rotors are housed (sect. 1.3.5 lists the types of rotors used), which rotate
synchronised in the opposite direction to each other.
The pump body receives the process fluid from the suction inlet, originating from the plant of the Customer. During the operation of the LDPU, the cavities
between the lobes of the rotors are filled with fluid and the counter-rotation of the rotors transfers the fluid to the delivery outlet of the pump body, chan-
nelling it in the plant where the LDPU is installed.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.4 - pag. 1
Rev.4 del 01/2011 O.M.A.C. s.r.l.

4.2 Controls
The LDPU can be equipped, upon request of the Customer and as an additional optional feature, with an electric control panel, where the “control ac-
tuators” are positioned for its operation.
All control, signalling and adjustment devices are marked with symbols and codes that enable to quickly understand their functions, as described below.
The same devices are marked with different colours: each colour has a specific meaning.
COLOURS FOR LUMINOUS INDICATORS MEANING CONTROLS MEANING
RED DANGER / ALARM RED EMERGENCY ACTION (STOP / DISABLING)
YELLOW ATTENTION YELLOW INTERVAL
GREEN SICUREZZA GREEN START / ENABLING
WHITE NEUTRAL
BLUE ACCORDING TO NEEDS

Below there is the illustration of the basic composition of an electric panel:


In the figure to the side one can identify:

A MAIN SWITCH
B LINE WARNING LIGHT
C CIRCUIT BREAKER TRIPPED WARNING LIGHT
B C D ON BUTTON + ON WARNING LIGHT
E EMERGENCY STOP BUTTON
A
The main switch, marked with letter A, is for powering or insulating the
machine electric unit, position “0” indicates the absence of voltage, position
“1” indicates the presence of voltage with the pump that operates with a cer-
tain rotation direction, position “2” indicates the presence of voltage with the
E pump that operates with the rotation direction opposite to that of position “1”.
D
When main switch A is in position “1” or in position “2”, one cannot open the electric panel because in this position opening is inhibited by an interblock.
One can open the control panel only by putting the switch in “0” position.
The indicator light, marked with letter B, when on indicated that the electric panel is “under voltage”. this condition occurs only if button A is in position
“1” or in position “2”.
The emergency stop button, marked with letter E, has the function to block the operation of the LDPU with immediate effect, in emergency
conditions. .
However it can be used to stop operation of the LDPU even in case of normal functioning, when switch A is not present.

NOTE
The particular “mushroom” shape of the button enables easy and quick intervention of the operator, in addition a mechanical retention blocks it in pressed
position.

Only after having released the button can one restore the normal operation conditions of the LDPU. One can rearm the button by slightly rotating the
knob anti-clockwise.
The on button, marked with letter D, is for starting the LDPU in normal and continuous operation mode. The
on and off conditions are signalled by the green light incorporated in the button: when the warning light is on it indicates that the LDPU is on, when it is
switched off it indicates that it is off.
The indicator light, marked with letter C, which indicates “CIRCUIT BREAKER TRIPPED”, lights up for an operation anomaly
of the LDPU, the electric motor is in overload. To reset normal operation conditions one must restore the “circuit breaker” as specified in the use and
maintenance instructions of the electrical supply.
The electric control panel can be equipped with an inverter, as an additional optional feature: it can be identified, in the figure below, with
letter G, which indicates the operation warning light, and with letter F, which indicates speed adjustment potentiometer, which is needed to
set the electric power supply voltage manually.

An inverter is in fact an electronic device able to vary the rotation


F speed of electric motors, which is directly associated with the supply
voltage frequency.
Section 4.2.1.1 shows a simple mathematical formula for calcu-
lating the power supply frequency, knowing the number of output
G revolutions of the control unit.

O.M.A.C. s.r.l.
Chap.4 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

4.3 LDPU volumetric capacity adjustment methods


On the basis of the production needs of the Customer, one can adjust the power supplied by the LDPU. The adjustment of the volumetric capacity of the
LDPU can be carried out in two ways:
• acting on the inverter adjustment, if the LDPU is equipped with an inverter;
• acting on the speed controller hand-wheel adjustment, if the LDPU is equipped with a mechanical speed controller.

4.3.1 Adjustment of the volumetric capacity with the inverter


This operation, i.e. the variation of the electric motor speed via inverter, must be carried out by the operator in charge of running the plant: he must rotate
the speed adjustment potentiometer knob on the electric panel, setting it on the desired frequency value, expressed in Hz.
The result of the frequency adjustment, with the potentiometer, translates in a speed variation of the electric motor revolutions and consequently in a
capacity variation of the LDPU.
The operator must read the consequent volumetric capacity variation on the meter placed on the delivery piping near the LDPU (see stage 2 section
3.3.3).

Frequency calculation.
It is assumed one has an electric motor that supplies a current number of output revolutions, Ncurrent at the national electric network frequency, equal to
50 [Hz] and that we will indicate more in general with Fcurrent. Assuming one wants to obtain a different number of output revolutions Nnew the frequency
with which the inverter must be set, fnew will be equal to: fnew = (Fcurrent * Nnew )/ Ncurrent

4.3.2 Adjustment of volumetric capacity via mechanical speed controller


This operation, i.e. the speed variation of the speed controller, must be
carried out by the operator in charge of running the plant:
12 15 17 21.5 25
SPEED CONTROLLER

he must act on the mechanical speed controller hand-wheel, only after 1000
11 21
having started the LDPU.
24
950 14 16
20
23
WARNING 9 10 15
900
Adjust the mechanical speed controller hand-wheel, 13 19
VARIATORE

22
only after having started the LDPU. The adjustment of 14
850 18 21
the speed controller must not be carried out with the 8 9 12
13 20
machine off as it can cause the breakage and malfunc- 800 17
DELTHE

11 12 19
tioning of the speed controller. 8
750 7 16
11 18
[RPM] OF

10
Before adjusting the hand-wheel, read the value the speed controller is 15
CORRISPONDENTI

700 17
set on, in the hand-wheel panel. The hand-wheel panel is shown 7 10
9 14 16
in figure A. Below, in the table placed to the side as an example, one can 650 6
REVOLUTIONS

obtain the value of the LDPU revolutions. 9 13 15


6 8
For example, if we are in presence of a size “10” speed controller and 600 12 14
the hand-wheel (figure A) has the arrow on 5, simply trace a vertical 8
5 7 13
line, starting from the column corresponding to the “10” size, until 5, 550 11
5 7 12
indicated by the hand-wheel, to then proceed horizontally, towards the 6 10 11
[RPM]

500
left until reading the corresponding number of revolutions at which the 4 6
OUTPUT

9 10
speed controller operates, i.e. 450 RPM. 450 4 5
8 9
GIRI IN USCITA

5
400 3 7 8
4
CORRESPONDING

1 0 19 3 4 6 7
2 18 350 6
3 3 5
3 17 2 5
300 2 4
2 2 4
4 16 3 3
250 2 2
5 15 1 1 1 1
1 1
190 0 0 0 0 0 0
6 14
7 13 03 05 10 20 30-50 100
8 12
9 10 11 QUANTITIES
GRANDEZZE REFERRED
RIFERITE TO
AI VARIATORI
MOTOVARIO/SPAGGIARI
MOTOVARIO/SPAGGIARI
figure A SPEED CONTROLLERS

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.4 - pag. 3
Rev.4 del 01/2011 O.M.A.C. s.r.l.

4.4 Work cycle description


The LDPU, whose functional element is the “B series lobe displacement pump”, is equipped with a control unit that, depending on the version, can be
fitted with a speed controller, a gear motor, an electric motor, a pneumatic motor or a hydraulic motor, with or without electric panel.
The capacity adjustment is achieved by increasing or decreasing the number of revolutions of the “B series lobe displacement pump”, intervening directly
on the revolutions output of the motor mentioned above or acting on the actuators on the control panel (inverter), if fitted.
The LDPU is reversible: full performance can be achieved in both rotation directions of the pump rotors (section 1.3.5 lists the types of rotors used).
The pumping action of the “B series lobe displacement pump” is achieved thanks to the counter-rotation of two rotors (letter “C” indicated in the figure in
section 1.2, indicating one of the two rotors), housed inside the pumping chamber (letter “U” indicated in the figure in section 1.2 or see figure below). The
rotors are assembled on rotating shafts supported by bearings (letters “G” and “H” shown in the figure in section 1.2), which are housed in the external
gearbox (letter “S” shown in the figure in section 1.2). Via a couple of sprocket wheels (letters “N” and “P” indicated in the figure in section 1.2) one
transfers motion from a drive shaft (letter “M” indicated in the figure in section 1.2) to a driven shaft (letter “R” indicated in the figure in section 1.2). The
synchronism of the rotors is such that they rotate without coming into contact with each other: in this conditions “the rotors are in phase”.
When the lobes of the rotors move away from each other, the volume between them increases, creating a decrease in pressure near the suction outlet:
this enables a certain volume of fluid to enter (value of fluid transported identified in the table in section 1.3.1, in the “theoretical capacity” column, de-
pending on the pump model size) into the pumping body. The fluid is transported along the internal of the pumping chamber, from the suction inlet to
the delivery outlet of the pump body. When the volume of fluid, trapped between the lobes and the external perimeter of the pumping chamber, reaches
in proximity of the delivery outlet, the counter-rotation of the two rotors creates a sudden decrease of available volume and a consequent increase in
pressure that pushes the fluid out of the pumping body, by channelling it into the plant where the LDPU is installed.

4.5 Cycle start instructions


The start of the LDPU work cycle is supervised and activated by the operator in charge of running the plant, after having carried out the following preli-
minary checks.

4.5.1 Preliminary operations: check list


Before commissioning the “B series lobe displacement Pump Unit” check the following:
• if the LDPU has suffered damages, contact the O.M.A.C. s.r.l. Technical Office immediately as described in chapter 2;
• make sure that all the bolted connections are tightened properly and that the installation of the LDPU has been carried out properly in accor-
dance with the requirements of this use and maintenance manual;
• ensure continuity of the equipotential protection circuit and that it is connected, as per section 3.5.1.1 of this use and maintenance manual;
• ensure that all hydraulic connections, where required by the configuration of the LDPU, are carried out properly, as described in chapter 3;
• make sure, as a preventive measure, that there is lubricant oil, visible via the oil level cap placed on the side of the pump gear box, part of the
LDPU: please bear in mind that all pumps fitted in the LDPU are already supplied with the proper amount of lubricant oil.

DANGER
Incorrect lubrication or lubrication with lubricant products incompatible with the materials used in the construction and completion of the LDPU can lead
to premature wear or breakage of the sealing elements or other parts in contact with the process fluid.

ATTENTION
O.M.A.C. s.r.l. is not liable for any damage caused by improper use of lubricants incompatible with the materials used in the construction and completion
of LDPU or with the process fluid:
• ensure that the power supply voltage of the LDPU is that required as shown on the electric motor data plate or electric panel; it is reminded that
the electric connection must be carried out by skilled personnel and compliant with the electric motor data plate, both for the connection of the terminal
board and for the thermal calibration in accordance with the maximum admitted absorption;
• ensure that the pipes have been washed with clean water, to remove foreign bodies, cinders, dust or scraps from processes carried out on
the plant;
• with reference to chapter 3 ensure that a CIP/SIP cleaning and/or sanitisation cycle has been carried out, as per section 3.4;
• if there is a mechanical safety valve on the front cover or a bridge one on the external cover of the LDPU, check that the spring has been
adjusted, as indicated in section 3.3.3;
• if there is a pneumatic safety valve on the front cover of the LDPU, check that the auxiliary pneumatic unit pressure has been adjusted, as
indicated in section 3.3.3;
• make sure that all gates in suction and delivery are completely open, in order to ensure the suction pipes are full of process fluid;

ATTENTION
The LDPU must not be used to process fluids other than that / those for which it has been selected and sold, with reference to the intended use. If in doubt,
contact the O.M.A.C. s.r.l. Technical Office. Fluids incompatible with the materials used in the construction and completion of the LDPU can damage the
same Unit, other parts of the unit and cause injuries and damages to the operators in charge of running the plant.

O.M.A.C. s.r.l.
Chap.4 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

4.5.2 First start-up

ATTENTION
The B series lobe displacement pump part of the LDPU can also operate when empty because the moving parts are not in contact with each other,
except for the sliding faces of the seals that, especially at high speeds, tend to overheat. For this reason, it is recommended to never let the B Series lobe
displacement pump operate dry for long periods so not to cause premature wear of the sealing parts.
The allowed dry operation period depends on the rotation speed and materials of the sliding faces of the seals but, in any case, it is recommended not to
exceed 5-10 minutes for soft materials and 10-15 seconds for hard carbides.

• start the LDPU possibly on reduced speed to then increase up to working speed, checking any anomalies (pump over-pressure, piping leaks,
cavitation, vibration, etc.);
• if the working speed is very high it is normal for the temperature of the pump gear box to reach 50°C - 60°C, especially in the first hours of
operation;

4.6 Stopping instructions


When the LDPU stops one must intervene on the electric control panel, present on the machine or on the plant of the Customer, and intervene on:
• emergency stop, if a situation of danger is occurring;
• general selector, for a machine stop.

Once one of the two buttons has been pressed, one must:
• disconnect power and block the power device so that the LDPU cannot be operated;
• close the valves placed on the suction and discharge side;
• de-pressurise, if present on the LDPU, the pneumatic safety valve on the front cover;
• empty and de-pressurise the pump and suction and delivery piping system connected to the LDPU;

DANGER
If the process fluid is very hot, or in any case above room temperature, one must let the LDPU cool down, with particular reference to the pump and parts
in direct contact with the process fluid, until reaching room temperature.

• carefully read Chapter 5 relating to assembly and disassembly of the LDPU, before carrying out any maintenance or inspection operation of
the LDPU;
• clean the outside of the pump before disassembly, as per section 3.4.1.1.

4.7 Instructions for restarting after a stop


In order to restart the LDPU one must:
• open the valves placed on the suction and discharge side;
• pressurise, if present on the LDPU, the pneumatic safety valve on the front cover;
• intervene on the electric control panel, present on the machine or plant of the Customer, and:
- move the selector from position “0” to position “1” or “2”, according to the rotation direction;
- press the START button.

4.8 Switch-off
To switch off the LDPU one must press the STOP key on the electric control panel present on the machine or on the plant of the Customer.

4.9 Emptying
To empty the LDPU, after machine down time, one must operate in the machine as described below:
• stop the plant, as described in section 4.6;
• use a hex spanner to remove the screws of the front the front cover and move the cover away from the pumping chamber;
• let the remaining fluid drain into a container to dispose of it according to the existing regulatory framework.
Once the excess fluid has drained from the pump body, fully remove the cover and continue with the required operations
(maintenance, parts replacement, dismantling, etc.).

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.4 - pag. 5
Rev.4 del 01/2011 O.M.A.C. s.r.l.

4.10 Residual risks


Listed below are the main residual risks that may occur in the “B series lobe displacement Pump Unit”, deriving from the incorrect execution of one of the
operations described in this manual.

CAUSES THAT MAY GENERATE RESIDUAL RISKS RESIDUAL RISKS


Removal of the front cover / Emptying / Leakage of fluid Contact with dangerous process fluid
Incorrect earthing Electric shock
Breakage of piping / Breakage of mechanical components Ejection of process fluid
Incorrect or incomplete fixing of the pump Unit / Support vibrations and movements / Misalignment between
Incorrect tightening of screws pump Unit and piping of Customer plant
Incorrect calculation of performances (capacity, pressure, speed) Rotors seizure, possible piping breakage
Incorrect closure of a valve upstream or downstream of the pump Unit Water hammer with projection of cover
Presence of metallic cinders in the plant of the Customer Possible seizure of rotors
Incorrect CIP/SIP Contamination of process fluid
Leakage from sealing parts Ejection of process fluid

4.11 Dangers generated by use


Incorrect use of the LDPU, generated by failure to comply in full or in part with the use and maintenance instructions contained in this UMM, can cause
technical dangers in the operation of the Customer plant.
Listed below are the incorrect ways to use the LDPU.
INCORRECT USE ARISING DANGERS
Use of the LDPU for transfers of fluid in different conditions of hygienic
Contamination of process fluid or degradation
level than those for which it has been of its organoleptic
of the organoleptic specifications
designed(*)
Incorrect execution of CIP/SIP Possible contamination of process fluid
Danger for health of operators in charge of using the plant of the Custo-
Failure to use personal protection equipment
mer
Failure to comply with the procedures described in chapters 3 and 4 of Malfunctioning of the plant of the Customer / Risks for the health of ope-
this manual rators

(*) The “B series lobe displacement Pump Unit” for alimentary use has been designed to ensure hygiene Level 1, in accordance with EN 14159.

4.12 Prohibited use


The unintended uses of the “B series lobe displacement Pump Unit” for chemical use or alimentary use are all those that are NOT covered under sections
1.4 and section 4.1.

ATTENTION
O.M.A.C. s.r.l. forbids any use not expressly indicated in this UMM and is not liable for any damage caused by unauthorised improper use of the LDPU
or with the process fluid.

4.13 Management of emergency situations


In the event of an emergency situation connected directly or indirectly to the LDPU, one must stop machine operation, intervening on the electric control
panel, present on the machine or plant of the Customer.
One can stop operation by pressing the emergency button, marked with letter “E” in section 4.2 of this chapter (red mushroom button on circular yellow
base).

O.M.A.C. s.r.l.
Chap.4 - pag. 6 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 5: B SERIES LDPU MAINTENANCE


Where provided, the contents of this chapter is specifically addressed to the internal company maintenance operator. This person, named directly
and formally by the Customer company management; has at least two years experience in this role and has the required technical abilities for operating
in safety conditions and interpret the technical indications contained in the above mentioned documentation properly.

DANGER
Before disconnecting the LDPU from its energy supplies, make sure that the plant or part of it is contained in complies with the following conditions:
• absence of product and eventually washing;
• absence of residual pressure;
• temperature of contact surfaces not dangerous.
Before carrying out any maintenance operation on the LDPU pump, ensure one has carried out the pump and plant stopping operations, described in
section 4.5 “Use of the line: stopping instructions”

During the LDPU assembly and disassembly operations, as during its routine and extraordinary maintenance, one must wear the personal protection
equipment, according to the operation and risk connected to the activity performed by the appointed operator, as described in section 1.9.

5.1 Troubleshooting and solving problems


FAILURE: HIGH POWER ABSORPTION BY GPVL
POSSIBLE CAUSES: REMEDIES:
Excessive medium viscosity Decrease the speed of the pump, increase the temperature of the medium

Low medium temperature Increase the temperature of the medium, heat the pumping case (within the limits given by the manufacturer)

Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Too tight packing gland Loosen the packing gland and tighten it rightly (see instructions)
Excessive pump speed Decrease the speed of the pump
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Not aligned joint Check the alignement between pump and drive device
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Wrong quantity / quality of gears oil Act according to the manufacturer’s instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure
Worn out rotors Replace rotors

FAILURE: GPVL JUST STARTING BLOCK


POSSIBLE CAUSES: REMEDIES:
Excessive medium viscosity decrease the speed of the pump, increase the temperature of the medium

Low media temperature increase the temperature of the medium, heat the pumping case (within the limits given by the manufacturer)

Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Worn out or untimed gears replace the gears or time them according to the instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure

FAILURE: UNPRIMED OF THE PUMP


POSSIBLE CAUSES: REMEDIES:
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Insufficient N.P.S.H (Net Positive Suction Head) se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Medium evaporates in inlet se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power

Air enters in inlet Check and tighten suction piping connections, tighten the packing glands and, if necessary, replace them

Presence of air in the suction Fill pumping case and feeding piping with liquid, expelling air
Not enough liquid level in the tank in the suction Increase medium level, lower suction opening position
Dirty or blocked valve or suction filter Clean filters

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.5 - pag. 1
Rev.4 del 01/2011 O.M.A.C. s.r.l.

FAILURE: UNPRIMED OF THE PUMP (follow)


POSSIBLE CAUSES: REMEDIES:
Excessive medium viscosity Decrease the speed of the pump, increase the temperature of the medium
Too loose packing gland Tighten the packing gland rightly (see instructions)
Excessive pump speed Decrease the speed of the pump

FAILURE: SEIZURE OF THE PUMP


POSSIBLE CAUSES: REMEDIES:
Excessive medium temperature Decrease the temperature of the medium, cool the pumping case
Presence of suspended particles in the medium Clean suction piping and install a filter on it
Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Too tight packing gland Loosen the packing gland and tighten it rightly (see instructions)
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Wrong quantity / quality of gears oil Act according to the manufacturer’s instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure

FAILURE: NO FLOW-RATE
POSSIBLE CAUSES: REMEDIES:
Wrong rotation direction Invert the rotation direction
Unprimed pump Fill pumping case and feeding piping with liquid, expelling air
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Insufficient N.P.S.H (Net Positive Suction Head) se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power
Presence of air in the suction Increase medium level, lower suction opening position
Dirty or blocked valve or suction filter Clean filters
The relief valve leaks Check the relief valve setting, clean sealing parts, substitute worn parts

FAILURE: LDPU LOW FLOW-RATE


POSSIBLE CAUSES: REMEDIES:
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Insufficient N.P.S.H (Net Positive Suction Head) se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power

Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Medium evaporates in inlet se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power

Air enters in inlet Check and tighten suction piping connections, tighten the packing glands and, if necessary, replace them

Presence of air in the suction Fill pumping case and feeding piping with liquid, expelling air
Not enough liquid level in the tank in the suction Increase medium level, lower suction opening position
Dirty or blocked valve or suction filter Clean filters
Insufficient medium viscosity Increase pump speed, decrease the temperature of the medium
Excessive medium temperature Decrease the temperature of the medium, cool the pumping case
Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Too loose packing gland Tighten the packing gland rightly (see instructions)
Insufficient pump speed Increase pump speed
Transmission belt slips Stretch the belt
Worn out rotors Replace rotors
The relief valve leaks Check the relief valve setting, clean sealing parts, substitute worn parts
Check the relief valve setting and the spring compression in the way that the spring will open at a 10% more of the
The relief valve is wrongly set
operating pressure
The relief valve vibrates Check the relief valve setting, check and clean the valve

O.M.A.C. s.r.l.
Chap.5 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

FAILURE: PORTATA IRREGOLARE


POSSIBLE CAUSES: REMEDIES:
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Insufficient N.P.S.H (Net Positive Suction Head) se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Medium evaporates in inlet se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power
Air enters in inlet Check and tighten suction piping connections, tighten the packing glands and, if necessary, replace them
Presence of air in the suction Fill pumping case and feeding piping with liquid, expelling air
Not enough liquid level in the tank in the suction Increase medium level, lower suction opening position
Dirty or blocked valve or suction filter Clean filters
Too loose packing gland Tighten the packing gland rightly (see instructions)
Excessive pump speed Decrease the speed of the pump

FAILURE: NOISE PUMP AND LDPU VIBRATION


POSSIBLE CAUSES: REMEDIES:
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Insufficient N.P.S.H (Net Positive Suction Head) se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power
Increase the head, the piping inlet diameter, reduce the suction piping lenght and the number of the bends, decrea-
Medium evaporates in inlet se the speed of the pump and the temperature of the medium, check that the increase (caused by the decreasing
temperature) is suitable to the motor power

Air enters in inlet Check and tighten suction piping connections, tighten the packing glands and, if necessary, replace them

Presence of air in the suction Fill pumping case and feeding piping with liquid, expelling air
Not enough liquid level in the tank in the suction Increase medium level, lower suction opening position
Dirty or blocked valve or suction filter Clean filters
Excessive medium viscosity Decrease the speed of the pump, increase the temperature of the medium
Excessive medium temperature Decrease the temperature of the medium, cool the pumping case
Presence of suspended particles in the medium Pulire la tubazione di alimentazione, installare un filtro di alimentazione
Too loose packing gland Tighten the packing gland rightly (see instructions)
Excessive pump speed Decrease the speed of the pump
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Not aligned joint Check the alignement between pump and drive device
Pump or drive device not fixed on the base Tighten bolts and re-check the alignement between pump, device and joint
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Wrong quantity / quality of gears oil Act according to the manufacturer’s instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure
The relief valve vibrates Controllare la regolazione della valvola, ispezionare e pulire la valvola
Check the relief valve setting and the spring compression in the way that the spring will open at a 10% more of the
The relief valve is wrongly set
operating pressure

FAILURE: OVERHEATING OF THE PUMP


POSSIBLE CAUSES: REMEDIES:
Excessive medium viscosity Decrease the speed of the pump, increase the temperature of the medium
Excessive medium temperature Decrease the temperature of the medium, cool the pumping case
Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Too tight packing gland Loosen the packing gland and tighten it rightly (see instructions)
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Not aligned joint Check the alignement between pump and drive device
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Wrong quantity / quality of gears oil Act according to the manufacturer’s instructions

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.5 - pag. 3
Rev.4 del 01/2011 O.M.A.C. s.r.l.

FAILURE: OVERHEATING OF THE PUMP (follow)


POSSIBLE CAUSES: REMEDIES:
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure
The relief valve leaks Check the relief valve setting, clean sealing parts, substitute worn parts

FAILURE: OVERHEATING OF THE MOTORIZATION


POSSIBLE CAUSES: REMEDIES:
Low medium temperature Increase the temperature of the medium, heat the pumping case (within the limits given by the manufacturer)

Excessive medium viscosity Decrease the speed of the pump, increase the temperature of the medium
Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Too tight packing gland Loosen the packing gland and tighten it rightly (see instructions)
Excessive pump speed Decrease the speed of the pump
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Not aligned joint Check the alignement between pump and drive device
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Wrong quantity / quality of gears oil Act according to the manufacturer’s instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure
Worn out rotors Replace rotors

FAILURE: FAST ROTORS WEAR


POSSIBLE CAUSES: REMEDIES:
Excessive medium temperature Decrease the temperature of the medium, cool the pumping case
Presence of suspended particles in the medium Clean suction piping and install a filter on it
Remove possible obstructions in the outlet piping, increase the piping diameter, reduce its lenght and the number of the
Excessive back-pressure
bends
Piping press on pumping case Check the piping alignement, if necessary fit flexible expansion joints, and fix the piping on the plant structure
Worn out bearings Replace the bearings by the manufacturer
Worn out or untimed gears Replace the gears or time them according to the instructions
Parts in contact in the pumping case Check the design pressure coincides with the operating pressure

FAILURE: FAST SEALS WEAR


POSSIBLE CAUSES: REMEDIES:
Presence of suspended particles in the medium Clean suction piping and install a filter on it
Too tight packing gland Loosen the packing gland and tighten it rightly (see instructions)
Insufficient flushing seal liquid level Check the flushing seal liquid and, if necessary, increase its flow-rate

5.2 Instruction for carrying out checks


Before any maintenance intervention one must provide all the security measures that comply with the accident prevention regulations in force. In parti-
cular inhibit operation of all electric utilities and discharge any residual energy.
The instruments and tools needed for good maintenance are those normally supplied as standard to a technician with assembly/maintenance tasks.
In the case the machine is positioned above ground level it is up to the Customer to make the machine accessible to the operator in order to permit
adjustment, maintenance, repair, etc. operations possible, in safety conditions.
• In the case the process fluid is subject to easy drying, crystallisation or sedimentation, it is essential to wash the pump and pipes at the end
of each operation, i.e. at the beginning of extended machine down time.
• The reversibility of the rotation direction, common feature of all OMAC pumps, offers the possibility to recall the process fluid, completely
emptying the delivery pipes and putting the product in storage.
• If the LDPU is not use for a long period of time, when starting check that the sealing parts are not blocked by turning the pump shaft
manually.
• If the process fluid is subject to freezing or solidification, ensure before starting, that the pipes and the pump body are not obstructed by solid
parts of fluid, formed during inactivity.
• The references below, with position number, are to intended as the exploded view drawing of the B series lobe displacement pump indicated
in section 1.3.

O.M.A.C. s.r.l.
Chap.5 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.2.1 Daily checks


• Visual inspection of all sealing parts and of the general operation of the LDPU.
• If one experiences a loss of mechanical seals, see to replace them as soon as possible, to prevent the process fluid from entering the bearings
box or stagnating on the ground.

5.2.2 Weekly checks


• Check the oil level of the pump and motor unit, eventually top-up with oil of the kind indicated by the manufacturers, after having checked the
proper amount and the degree of viscosity on the respective use and maintenance manuals.
• Inspect the pumping chamber and free it from any scaling due to the kind of process fluid.
• Check that there is no seizing between the rotors and the static surfaces of the pumping body.
• Check that the mechanical safety valve on the cover, when provided, is not blocked by a long period of inactivity. To check simply remove the
adjustment screw completely (pos.59 page 29) and then adjust the calibrations of the spring again.

5.2.3 Six monthly checks


• If the LDPU works constantly at high temperatures, above 120°C, check the integrity of the pump lubricant oil; if it has gone dark in colour, see
to its replacement. The same goes for the motorisation unit; keep to the instructions of the manufacturer.
• Check that the distribution gears have not reached such a play to enable the rotors to come into contact; in this case replace the worn
gears.
• Check the stiffness of the shafts: if there is even minimal axial or radial play, see to the replacement of the bearings.
• Check the corrosion condition of the bearings box; if needed re-paint with suitable paint and protect it from premature wear. The “B series lobe
displacement pump” is painted as standard with EPOXY ENAMEL GLOSS RAL 7032.

NOTE
By systematically following these checks, the pump will maintain its original performances unchanged for many years.

5.3 Periodic checks of the safety and emergency devices


When the LDPU is fitted with an electric control panel, one must carry out weekly checks for the correct operation of the actuators and operation of the
relative warning lights.

5.4 Indication of dangerous temperatures


In the event of pumps predisposed for pumping products at high temperatures up to 150°C, there is a signal placed on the same pump that warns the
operators of the presence of high temperature surfaces, as shown in figure C:

5.5 Oils present


• Check the oil level placed on the side of the pump daily; it must always be completely full when the pump is switched off.
• If needed, restore the level by adding oil with reference to section 1.3.12 of this UMM, relating to the degree of viscosity and the proper
amount, expressed in litres, for every LDPU size.
• If the pump is used with vertical openings, check the proper position of the vent cap and level and if needed invert them.
• Oil replacement must take place after a run-in period of about 150 working hours, subsequently every 2500 hours.
• If the gear box works constantly at temperatures above 90°C, lubricate with oil with a higher degree of viscosity (see section 1.3.12) and
replace it every 1000 working hours.

5.6 Tests and checks


Listed below are the checks to be performed, at predetermined intervals, on the LDPU.

5.6.1 Lubrication
The LDPU has other mechanical elements that during maintenance require lubrication: these components are the sealing parts.
In assembly and disassembly operations there are the specifications relating to the surfaces to be lubricated with grease and the stages in which this
operation must be carried out.

5.6.2 Single mechanical seals


• Mechanical seals do not require any maintenance.
• When there is a leak, caused by wear and contact surfaces, see to replace the whole seals (see disassembly instructions).
• In case of extended operation with worn seals, check that some process fluid leaks outside the pumping body.

IMPORTANT: it is recommended to not let the mechanical seals turn when dry.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.5 - pag. 5
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.6.3 Mechanical seals with flushing


• Flushed mechanical seals, as simple mechanical seals, do not require any maintenance;
• When one replaces the mechanical seal, also replace the rotating ring (pos. 224) and the lip ring (pos. 223) of the auxiliary seal.
• With flushing connected adequately, the pump can operate even in absence of the product to be pumped, because the seals do not risk
over-heating;
• Check that flushing is always efficient, when the pump is operating, in order not to damage the auxiliary seals (connection diagram section
3.5.2);
• To disassemble the flushed mechanical seals, follow the instructions of the simple mechanical seals, described in this chapter;
• To remove the fixed part of the mechanical seal, disassemble the chamber (pos. 22) from the pumping body;
• When assembling, before inserting the rotating part of the mechanical seal on the shaft, position the rotating ring properly (pos. 224) and fit
the auxiliary sealing ring adequately (pos. 223) in its housing on the chamber (pos. 220), as per the section drawings in chapter 7, in the sections relative
to the sealing parts.
The purpose of flushing mechanical seals is generally to cool down and lubricate the sliding faces of the mechanical seal, via forced circulation of a
flushing liquid.
The flushing liquid and its distribution circuit must be provided by the Customer. The Customer must also check, through his Technical
Office, the compatibility between the flushing liquid and the process fluid, as well as the compatibility between the
flushing liquid and the components of the “B series lobe displacement Pump Unit” in close contact (pumping cham-
ber material, seals material, working temperature, etc.)
Once this requirement has been checked and validated, the Technical Office of the Customer will see to expressly authorise the operator responsible for
the installation of the LDPU to fit the flushing circuit on the seals flushing chamber and commission it, before starting the LDPU for the first time.

ATTENTION
The operator responsible for fitting the flushing circuit must be expressly authorised by the Technical Office of the Customer to connect the same flushing
circuit to a system that uses “flushing liquid” compatible with the process fluid.
O.M.A.C. s.r.l. is not responsible for improper use of the flushing liquid nor for damages deriving from contamination of the process fluid.

DANGER
Improper use of the flushing system can cause breakage of the mechanical seals with consequent damage of the LDPU and contamination of the process
fluid.
O.M.A.C. s.r.l. is not responsible for improper use of the flushing system.
The operator designated by the Customer must connect the flushing circuit joints to the input and output holes of the seals flushing chambers and adjust
the temperature and pressure according to the type of seal fitted on the displacement pump, as described below:
• in case of single mechanical seals the flushing pressure must be about 1.5 - 2 bar with 0.5 - 1 lt of flow-rate;
• in the case of double mechanical seals the flushing pressure must be equal to the working pressure or higher by 1 bar, to ensure that the
film created between the sliding faces of the seals is made up of the flushing liquid and not by the process fluid, which according to its chemical compo-
sition may crystallise and solidify after machine down time and generate, upon restarting the unit, a “sticking” phenomenon of the faces, causing their
breakage.
The flushing temperature must be established according to the type of processed fluid and to the flushing utility: generally using liquid at room tempera-
ture - about 15° - 20° - is necessary to disperse the heat generated by friction of the seals faces, or vice-versa, using liquid at higher temperatures, for
example 80° - 90°, can be useful for melting, removing, cleaning and lubricating the seals faces.
The dimensions of the inlet and outlet holes joints of the flushing circuit are listed in the table in section 1.3.9 in chapter 1.

5.6.4 Mechanical seals balancing


All mechanical seals fitted on the B series lobe displacement pumps are equipped with a balancing ring of the fixed parts, to cope with severe operating
conditions such as:
• pressure peaks due to the first break-away or start-ups under load;
• particularly viscous or sticky product;
• frequent start-ups.

IMPORTANT: the balancing ring must not strain on the fixed part of the seal; check that there is slight play (about 0.05/0.3 mm).

5.6.5 Packing seals


• The tightening of packing seals is carried out when the pump is tested;
• After a few hours of operation there is an adjustment of the packing, consequently one must adjust it further, being careful to leave slight
dripping that enables lubrication of the sealing rings.
• When the dripping leakages are excessive and one cannot tighten any further, replace the packing and shaft protection sleeve.

O.M.A.C. s.r.l.
Chap.5 - pag. 6 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.7 Disassembly and assembly operations of B100 size pump.


This section lists the disassembly / assembly operations of the B100 size lobe pump.

B100 Section

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.5 - pag. 7
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.7.1 Disassembly of the pumping body


Before removing the cover, ensure that the pump and motor are insulated, that the pump is cold enough to be touched safely, that all fluids have been
discharged and make sure that the pump body is insulated and de-pressurised. If the end cover is fitted with a by-pass valve consult the relative section.
Then proceed as follows:

1 2 3
1 Remove the front nuts and exert leverage in
the provided slots on cover

2 Unscrew anticlockwise the rotor nuts, inter-


posing a non metal element between the rotors,
making them stop rolling

3 Take care of the reference marked on rotors


and shafts (1-2) so that you will set them rightly 4 5
while reassembling

4 Extract the rotors, taking care you don’t dama-


ge them by means of metal tools
5 extract the rotor case
6 Extract the rotating part of the mechanical
seal from the shaft, after disassembling the bea-
ring retainers 6 7 8
7 Untighten the socket head screws on mecha-
nical seal

8 Extract the rotating part of the mechanical


seal from the shaft

5.7.2 Assembly of the pumping body

ATTENZIONE
9 During the following operations, take care you don’t damage the lapped seal surface; don’t lay them on the bench and handle them with clean hands

10 Clean carefully the shafts. Lubricate lightly


the O-ring and introduce the rotating part of the 10 11 12
seal, possibly by means of a conical bush Exert
pressure only with hands; avoid using metal
tools

11 Be sure the mechanical seals stand on the


shaft shoulder and tighten step by step the soc-
ket head screws. We suggest you should use a
thread locking adhesive in order to avoid their
untightening on work
13 14

12 Assemble the stationary part of the seal on


rotor case, taking care to aline the slot with the
retainer pin, already arranged on seat bottom

13 Clean carefully the seal slide surfaces and assemble the rotor case delicately in order not to damage the seals and be sure it is well set on plugs.
Clamp the back nuts

14 Assemble the rotors, setting them on pitch setting, according to reference marks (1-2). Clamp the rotor nuts (see cap.1.3.6). In order to stop turning,
interpose a non metal element between rotors

O.M.A.C. s.r.l.
Chap.5 - pag. 8 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.7.3 DISASSEMBLY OF THE BEARINGS BOX


15 After disassembling the rotor case, drain the 15 16 17
oil and the remove drive key on shaft

16 Remove the gear cover and make a refe-


rence mark on gears in order to respect the right
timing while reassembling

17 Disconnect the retainer keys on lock 18 19 20


washers

18 Unscrew the gear ring nut, inserting a non


metal wedge between gears in order to stop
turning 21 22
19 Disassemble the shafts, unscrewing the fl
athead screw, with the lock washer
20 Extract the shafts by the posterior side of
the pump
21 extract the oil retainer and the external rings 22 extraxt the spacers and the snap rings
of the front bearing

5.7.4 Assembly of the bearing box


23 *BEARING ASSEMBLING PHASE*
Prepare the shafts and the bearings, checking 23+24 25 26
they are without dents and burrs

24 Drive the inner ring on the driving shaft. Re-


peat the operation on the drived shaft

25 Assemble the rear bearing on the driving


shaft and then on the drived one 27 28 29

26 Drive the external bearing rings on the gear


box, observing the depth on the fi gure (10 mm)

27 Insert the snap rings and the spacers for


the axial setting 30 31 32 33
28 Assemble the shafts by the rear side of the
pump, respecting the timing previously marked
while reassembling, with the numbers marked
“1” and “2” turned towards the high
29 Fixed the rear bearings with the washers
and the flathead screws
30 The gear couple is composed by a fi xed gear and an adjustable one. Assemble the fixed gear, then the adjustable one with untightened screws,
taking care to a first approximate rotor timing
31 Tighten the retainer ring nuts with the corresponding safety washers and set rightly the suited retainer key. In order to avoid turning during operation
insert a wedge in soft material among the gear teeth
32 Assemble the rotor case and rotors as previously described and check the “Clearences” (see par.1.3.4).
If rotor clearances are not included in tolerances as prescribed in chap. 1, disassemble rotors, the rotor case and adjust the spacer according to the
requested dimension
33 Being the wedge inserted among the gears tighten the rotor nuts, taking care of the driving torque (see par.1.3.6)

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.5 - pag. 9
Rev.4 del 01/2011 O.M.A.C. s.r.l.

34 35 36
34 Time perfectly the rotors and tighten the
screws of the adjustable gear gradually, che-
cking the rotor timing

35 Tighten completely the adjustable gear


screws taking care of the driving torque (see
par.1.3.6)
N.B. IN CASE OF RE-TIMING IT’S NECES-
SARY TO REPLACE THE PLANE WASHERS,
CAVED BY PREVIOUS CLAMPING
36 Assemble the gear cover, taking care to set the O-ring gasket and insert the key on the shaft. Put into bearing housing the oil quantity as per
chap.1.3.12

5.7.5 Disassembly of the lip seals

ATTENTION
IT IS RACCOMMENDED TO SUBSTITUTE LIP SEALS, IN CASE OF WEAR, TO BADLY AVOID SPILLAGES OF PRODUCT FROM THE PUMPING
CASE AND THE MALFUNCTION OF THE PUMP
PERFORM FIRSTS OPERATIONS 1,2,3,4,5 AS IN THE PAR. 5.8.1, THEN OPERATE AS FOLLOW
6 IN BOTH CASES OPERATE AS FOLLOWS:
extract the stationary parts of the seals from
6 Lip seal type 6 Lip seal type 7
HN ELRING S1 Sintek H-TPU
rotorcase, after disassembling the retainers
rings
7 after untightening the security dowels, extract
the rotating part of the seal from the shaft

5.7.6 Lip seals assembling

8 Put the O-Ring into the rotating part of the 10 with lip seal type HN ELRING: Assemble the stationary part ( l’anello HN Elring) on the
seal and screw the security dowels pumping case, then assemble the retainer ring with its hexagonal-head screws
9 Lubricate the shafts before inserting the rota-
ting part of the seals, taking care not to damage 11 Clean carefully the seal slide surfaces and assemble the rotor case delicately, in order not to
O-Ring. damage the seal and be sure it is well set on plugs.
Be sure the rotating part is on the shoulder of the Clamp the front nuts
shafts and tighten the security dowels.
It is raccommended using a threads-locking glue
to avoid unscrewing during the rotational motion 12 Assemble the rotors, setting them on pitch setting, according to reference marks (1-2). Clamp the
rotor nuts (see chap. 4.5). In order to stop turning, interpose a non metal element between rotors

ATTENZIONE 8 9 10 Lip seal type HN ELRING


TAKE CARE OF THE RIGHT POSITIONING OF
THE RETAINER RING, AS FOLLOWS

10 with lip seal type S1 SINTEK H - TPU: 10 Lip seal type S1 Sintek H-TPU 11 12
Assemble the stationary part (SINTEK H - TPU
RING)on the pumping case, then assemble the
retainer ring with its hexagonal-head screws

O.M.A.C. s.r.l.
Chap.5 - pag. 10 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.8 Disassembly and assembly operations of size B1/B2/B3/B4/B470/B490 PUMP


This section lists the disassembly / assembly operations of the B1/B2/B3/B4/B470/B490 size lobe pump.

B105 - B110 - B115 Section

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.5 - pag.11
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

Sezione B2/B3/B4/B470/B490

O.M.A.C. s.r.l.
Chap.5 - pag. 12 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.8.1 Disassembly of the pumping body


1Remove the front nuts and exert laverage in 1 2 3
the provided slots on cover
2 Unscrew anticlockwise the rotor nuts, inter-
posing a non metal element between the rotors,
making them stop rolling
3 Take care of the reference marked on rotors
and shafts (1-2) so that you will set them rightly
while reassembling 4 5 6
4 Extract the rotors, taking care you don’t dama-
ge them by means of metal tools

5 Unscrew the back nuts and extract the rotor


case
6 Extract the stationary part of the mechanical
seal from rotor case 6 7 8
7 Untighten the socket head screws on mecha-
nical seal
8 Extract the rotating part of the mechanical
seal from the shaft

5.8.2 Assembly of the pumping body

9 During the following operations, take care you don’t damage the lapped seal surface; don’t lay them on the bench and
ATTENTION handle them with clean hands

10 Clean carefully the shafts. Lubricate lightly the O-ring and introduce the rotating part of the seal, possibly by means of a conical bush. Exert pressure
only with hands; avoid using metal tools
11 Be sure the mechanical seals stand on the shaft shoulder and tighten step by step the socket head screws. We suggest you should use a thread
locking adhesive in order to avoid their untightening on work
12 Assemble the stationary part of the seal on rotor case, taking care to aline the slot with the retainer pin, already arranged on seat bottom

13 Clean carefully the seal slide surfaces and


assemble the rotor case delicately in order not
10 11 12
to damage the seals and be sure it is well set on
plugs. Clamp the back nuts

13 14
14 Assemble the rotors, setting them on pitch
setting, according to reference marks (1-2).
Clamp the rotor nuts (see cap.4.5). In order to
stop turning, interpose a non metal element
between rotors

5.8.3 Disassembly of the bearings box

15 After disassembling the rotor case, drain 15 16 17 18


the oil and the remove drive key on shaft

16 Remove the gear cover and make a re-


ference mark on gears in order to respect the
right timing while reassembling

17 Disconnect the retainer keys on lock


washers
18 Unscrew the gear ring nut, inserting a non metal wedge between gears in order to stop turning
O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.5 - pag.13
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

19 20 21
19 Extract the gears, exerting leverage between
the bea ring housing and the gears side, without
damaging the toothing outline

20 On assembling and disassembling we sug-


gest you should replace the gears with a spacer
in order not to break down the pre-assembled
bearing 22 23

21 Remove the bearing retainers


22 Extract the shafts by means of a non metal
hammer
23 Mark the spacers for the axial shaft adjustment, then replace them rightly while re-assembling

5.8.4 Assembly of the bearings box


24 *FRONT BEARING ASSEMBLING PHASE1*
If you replace bearings with others that are not supplied by OMAC, you must mark, with the electric pen, the internal ring of a bearing with the # symbol.
Check with depth micrometer gauge the dimension “x” according to the table, take it without the inner spacer and the inner ring with roller set on the
opposite side of #
25 PHASE 2
USE GLOVES. Heat the inner ring # up to ca 24 25 26
150° C and assemble it on the shaft. Wait for the
temperature to drop to room temperature. Value
of the measurement “X” (+/- 0.02)
26 PHASE 3
Assemble the bearing. Insert the inner spacer
the first time just lapped with lapping machine.
Consider the axial clearance between the rollers
and carry out another lapping until you obtain a
preloading on the bearings of about 0,05 mm. 27 28 29
The best assembling is obtained when the bea-
rings, tightened with the ring nut, roll freely and
the outer spacer is slightly blocked but moves
exerting a radial pressure with fingers. For ti-
ghtening torques see chap. 1

27 Assemble the pre-assembled front bearing, tighten firmly the ring nut and
set the retainer key in the ring nut slot
IMPORTANT: Put all keys of the safety washer up to the ring nut in order to
let the spacer pass for the axial adjustement

30 - B1
28 REAR BEARING ASSEMBLING PHASE1
Measurement of the “Y” dimension without the inner
spacer
29 ATTENTION Bearing spacer (pos. n°10 fi g.12.2) has to be placed only
on B2 size.
30 PHASE 2
Measurement of the “Y1” dimension without the outer spacer , without an outer
ring and with the inner spacer, which must be inserted the fi rst time just lapped,
then the second time with the correct measure in such a way that: Y1 = Y -0.05-0.10

O.M.A.C. s.r.l.
Chap.5 - pag. 14 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

31 Assemble the pre-assembled rear bearing, tighten the ring nut inserting a
spacer suitable for replacing the gear, in order to keep assembled the bearing
during the assembling operations

32 Set the spacers for axial shaft adjustment and assemble the shafts with the
30 - B2 - B3 already fixed bearings
B4 - B470 - B490

33 Set the O-ring gasket in its seat and assemble the bearing retainers with oil
lip seal already fi xed. Assemble the rotor case and rotors as previously descri-
bed and check the “Clearences” (see chap.1)

34 If rotor clearances are not included in tolerances as per chap. 1, disas-


semble rotors, the rotor case and adjust the spacer according to the requested
dimension. N.B. A spacer set can be requested to the manufacturer company

35 Remove the spacers used for the assembly and insert the keys for gear
drive in their seats with a lightly forced connection

36 The gear couple is composed by a fi xed


gear and an adjustable one. Assemble the fi xed 31 32 33
gear, then the adjustable one with untightened
screws, taking care to a fi rst approximate rotor
timing

37 Tighten the retainer ring nuts with the corre-


sponding safety washers and set rightly the sui-
ted retainer key. In order to avoid turning during
operation insert a wedge in soft material among 34 35 36
the gear teeth

38 Being the wedge inserted among the gears


tighten the rotor nuts, taking care of the driving
torque (see chap.1)

39 Time perfectly the rotors and tighten the


37 38 39
screws of the adjustable gear gradually, che-
cking the rotor timing
N.B. IN CASE OF RE-TIMING IT’S NECES-
SARY TO REPLACE THE PLANE WASHERS,
CAVED BY PREVIOUS CLAMPING
Tighten completely the adjustable gear screws
taking care of the driving torque (see chap.1)
40
40
Assemble the gear cover, taking care to set the
O-ring gasket and insert the key on the shaft.
Put into bearing housing the oil quantity as per
chap.1

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.5 - pag.15
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.9 Disassembly and assembly operations of B550/B660/B680 size pump


This section lists the disassembly / assembly operations of the B550/B6 size lobe pump.

B550 Section

O.M.A.C. s.r.l.
Chap.5 - pag. 16 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

B660 B680 Section

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.5 - pag.17
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.9.1 Disassembly of the B660/B680 pumping body


1 Remove the end cover and untighten the two 1 2 3
locking nuts of the rotors

2 Untighten the back nuts and remove the rotor


case
3 Unscrew anticlockwise the rotor nuts, inter-
posing a non metal element between the rotors,
making them stop rolling

4 Take care of the reference marked on rotors 4 5 6


and shafts (1-2) so that you will set them rightly
while re-assembling

5 Extract the rotors, taking care you don’t dama-


ge by means of metal tools

6 Untighten the two security screws and remove


the seal flange
7 8 9
7 Extract the stationary part of the seal from the
support fixed on seal flange
8 Untighten the socket head screws on mecha-
nical seal
9 Extract the rotating part of the seal from the
shaft

5.9.2 Assembly of the B660/B680 pumping body

10 During the following operations, take care you don’t damage the lapped seal surfaces; don’t lay them on the bench and
DANGER handle them with clean hands
11 Clean carefully the shafts. Be sure the spa- 11 12 13
cers for the seals are set (295). Lubricate lightly
the O-rings and insert the rotating part of the
seals on the shafts.
Exert pressure only with hands; avoid using me-
tal tools

12 Be sure the mechanical seals stand on the


shaft shoulder and tighten by degrees the soc-
ket head screws. We suggest you should use a 14 15 16
thread locking adhesive in order to avoid their
untightening on work

13 Assemble the stationary part of the seals


on supports, taking care to aline the slot with the
retainer pin. Assemble these supports on seal
flange, setting the O-ring

14 Clean carefully the seal slide surface and assemble the seal fl ange delicately in order not to damage the seals. Be sure the fl ange is set according
to reference pins and tighten the suited screws

15 Assemble the rotors, setting them on pitch according to the reference marks (1-2). Clamp the rotors nuts (see tab. 14). In order to stop turning,
interpose a non metal element between rotors. Tighten the rotor nuts (see chap.1)

16 Assemble the rotor case, setting the O-ring


O.M.A.C. s.r.l.
Chap.5 - pag. 18 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

5.9.3 Disassembly of the B550/B660/B680 gear box


17 After disassembling the rotor case remove 17 18 19
the oil and the drive key on shaft

18 Remove the gear cover, disconnect the re-


tainer keys of the lock washer and unscrew the
ring nuts
19 Stand the pump upright and extract the two
bearing supports, making use of the threaded
holes for removal.
20 21 22
Doing so you will remove the spacers for axial
adjustement too, which should be marked and
separated for a right re-setting while assembling

23 24

20 Remove the ball bearing from its support,


taking away the bull ring
21 Mark the gears in order to set them rightly
while reassembling

22 Withdraw the shafts, with the gears, still inserted. For this operation we suggest a mechanical lifting equipment, which can use the threaded holes
arranged on shaft ends
23 Remove the inside ring of the roller bearing by means of an extractor. Remove the gear taking care not to damage the toothing outline

24 Remove the bearing retainer and extract the outer ring of the roller bearing from the bearing box

5.9.4 Assembly of the B550/B660/B680 gear box


25 Assemble the outer rings of the roller bea-
rings on the bearing housing, using a bearing 25 26 27
retainer to set them axially, because no counter-
boring is arranged.
Assemble the bearing retainer without seal rin-
gs

26 USE GLOVES. The inner ring of the roller


bearing is assembled with a interference, there-
fore we suggest a shrink fi tting, heating the ring
in 90 °C oil bath, in order to avoid any seizure.
28 29
Insert the gear keys in their seats with a lightly
forced connection.
IMPORTANT: Assemble the adjustable gear on
the shaft, which will be set up on the pump

27 Assemble the shafts. If the gears heven’t been removed from the shafts, respect the timing previously marked while re-assembling

28 Insert the spacers (10) on the shafts and assemble the supports (75) with the ball bearings already connected. Set the spacers for axial adjustement
(11) and tighten the screws

29 Assemble the seal rings (18) on bearings retainers (9)


O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.5 - pag.19
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

30 Assemble the rotor case as previuosly 30 31 32


described; tighten the retainer ring nut with the
corresponding lock washers and set rightly the
retainer keys. In order to avoid turning during
operation insert a non metal wedge between
rotors

31 If clearance are not included in tolerances 33 34


as per cap.4.3, untighten the screws which lock
the back bearing supports, remove the spacers
and adjust them according to the requested di-
mension.
N.B. a spacer set can be requested to the manu-
facturer company

32 Time perfectly the rotors and tighten the screws of the adjustable gear gradually checking the rotor timing. You can reach the adjustable gear through
a window arranged on the top of the bearing housing

33 Tighten completely the adjustable gear screws taking care of the driving torque as described in chap.4.5
N.B. IN CASE OF RE-TIMING IT’S NECESSARY TO REPLACE THE PLANE WASHERS, CAVED BY PREVIOUSLY CLAMPING
34 Assemble the gear cover, taking care to set the O-ring and insert the key on the shaft. Put into gear box the oil quantity as per chap. 1

B550-B660-B680 PUMPS DRIVE SHAFT POSITION INVERSION

1 To invert the position of the drive shaft, one must completely disassemble the shafts from the pump body, as per instructions
above.

IMPORTANT!
Re operation n. 20: mark the B rotors, bearings supports (/%) and the adjustment spacers (11) to position them on the same shaft during assembly.

2 Remount the shafts in inverted positions, each with its details marked during disassembly. The gears must stay
in the original position with the same tooth and opening in the previous position to keep the timing. When the assembly is complete, check that the
clearances and the timing are within the tolerances under chapter 4.3. Introduce the amount of oil indicated in chapter 1.

5.10 POST MAINTENANCE CHECK


After maintenance activities, one must carry out tests to ensure the proper operation of the LDPU, before restarting the unit. To carry out these tests refer
to the check-list of section 4.5.1 of this manual.

O.M.A.C. s.r.l.
Chap.5 - pag. 20 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

CHAPTER 6: B SERIES LDPU DECOMMISSIONING

Where provided, the contents of this chapter is specifically addressed to the internal company maintenance engineer. This person, named directly and
formally by the Customer company management; has at least two years experience in this role and has the required technical abilities for operating in
safety conditions and understand and interpret the technical indications contained in the above mentioned documentation properly.

During assembly and disassembly operations of the LDPU, as in occasion of its routine and extraordinary one must wear
the personal protection equipment, according to the operation and risk connected to the activity performed by the appointed operator, as described in
section 1.9.

6.1 Disconnection from the sources of energy

DANGER
Before disconnecting the LDPU from its energy supplies, make sure that the plant or part of it is contained in complies with the following conditions:
• absence of process fluid and eventually washing of parts in contact with process fluid;
• absence of residual pressure;
• temperature of contact surfaces not dangerous.

As already highlighted inside this use and maintenance manual, the LDPU must be disconnected from the energy sources:
• electric (motorisation);
• hydraulic (driving force, flushing and/or aseptic unit when present);
• pneumatic (driving force, pneumatic safety valve, when present).

Disconnection of the LDPU from the energy sources requires strict compliance with the indications below:
• with reference to Chapter 4, stop operation of the LDPU (of every component) and consequently stop operation of the plant;
• once operation of the LDPU has been stopped, put every main switch in the plant in position “0”, so that every part of the line is insulated from
the power network (electric, etc.);
• make sure that the various “presence of voltage” warning lights are switched off;
• if an aseptic system and/or flushing system are present, make sure that the auxiliary liquid supply hydraulic control unit is switched off;
• when the LDPU requires compressed air to operate (presence of pneumatic safety valve), move the compressed air supply/discharge tap
lever in close/discharge position and wait for a few minutes. This way the machine is insulated from the pneumatic supply network and furthermore the
residual energy present inside the pneumatic circuit is discharged;

DANGER
Before disconnecting the lobe pump from its energy supplies, make sure that the upstream energy supply has been interrupted, that the hydraulic supply
has been interrupted, that the compressed air has been interrupted and there is no residual energy (i.e. for example: that the compressed air present in
the pneumatic plant has been discharged). Also check that the compressed air supply tap of your plant is closed.

• in case of electric supply, making sure that you do not have any parts of your body near the damp areas, remove the plug from the electric
system of the machine, from the electricity socket;
• if pneumatic supply is present, free the fixing of the pneumatic supply pipe;
• if hydraulic supply is present, free the fixing of the hydraulic supply pipe;
• pay utmost attention to possible leaks of remaining liquids. These leaks must be dried immediately in order to prevent slipping.
It is reminded that the operations needed to disconnect the LDPU from its energy supplies, for the complexity of the numerous checks / tests to be carried
out, must be performed by skilled personnel only.

Please be reminded that to operate the LDPU may need electricity, hydraulics and compressed air; connections that need to be disconnected carefully,
taking care to verify the absence of stored residual energy in addition to water leaks.

DANGER
if not formally authorised, do not attempt to disassemble parts of the LDPU.
O.M.A.C. S.r.l. is not liable for damages to things or persons during disassembly carried out by unauthorised personnel.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.6 - pag. 1
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

6.2 Disassembly
With reference to chapter 3, using PPE and the tools described herein, free the pump from its fixings, following the indications, in section 3.3 (installation),
in reverse order

ATTENTION
• use the proper P.P.E.;
• use the adequate tools;
• follow the procedure described in section 3.3 in reverse order;
• first of all disassemble the any optional features present on the pump;
• unscrew the suction and delivery connections from the plant;
• remove the fixing screws from the base;
• extract the LDPU from its position, using hoisting equipment.

DANGER
Considering the mass of the lobe pump, the hoisting and transfer stages must only be carried out by skilled personnel and under the direct supervision
of technical personnel headed by the respective manufacturers.
• using a clean cloth that does not leave any fluff, clean the external parts accurately (both externally and the easily accessible internal parts);

WARNING
For cleaning, only use a clean cloth that does not leave any fluff.
• free the LDPU from its anchoring;
• the unit is now free from its anchoring and ready to be handled, as defined in chapter 2 of this manual.

6.3 Storage after its use


After the disconnection and cleaning operations, put the LDPU in its original packaging, fixing it and trying to ensure good stability.
Using appropriate hoisting means, put the packed LDPU in a dry sheltered place at room temperature.

6.4 Demolition and disposal


Following the indications of the European Community Directives in force at the time of demolition, the user must take care of the disposal of the materials
that make up the machine.

It is good practice for the user, before demolishing the lobe pump, to communicate all the data carried on the nameplates and relating to the components
that will be demolished to the relative manufacturers.

The LDPU is made with materials that are not subject to specific obligations for toxicity and / or harmfulness and therefore do not require particular
disposal procedures, except for the oils present (with reference to section 5.6); substances that must be disposed of in compliance with the legislative
obligations in force, as indicated in the relative safety sheet, with reference to sections 5.8, 5.9, 5.10.

WARNING
The LDPU presents some substances that must be disposed of in compliance with the legislative obligations in force.
DO NOT DISPOSE OF THESE MATERIALS IN THE ENVIRONMENT

In case of demolition, the user, in accordance with the local law regulations, must take special precautions regarding the disposal of significant materials
from the environmental point of view, such as:
• plastic materials of pneumatic pipes (when present)
• coated electric cables (when present)
• any remaining toxic or corrosive substances
• Lubricant oil of the gear box.

O.M.A.C. s.r.l.
Chap.6 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

CHAPTER 7: B SERIES LDPU SPARE PARTS

Throughout his life, the LDPU may require the replacement of consumed or worn parts. To simplify the recognition of its consumption elements, O.M.A.C.
S.r.l. completes this manual with specifications defined for the identification of spare parts.
They are mainly spare parts that, if required, must be replaced only by skilled technical personnel authorised by O.M.A.C.

WARNING
Only skilled personnel authorised by O.M.A.C. S.r.l. can carry out extraordinary maintenance replacement interventions, performing the replacement
interventions of the components described below.

Do not try to replace parts without authorisation.

In case of replacing constructive mechanical parts that compose the LDPU, some of these need long manufacture time that can take a few months.
It is advisable to have enough of the components described above in the amounts deemed necessary to limit machine down time.

DANGER
Only skilled personnel authorised by O.M.A.C. s.r.l. can carry out extraordinary maintenance interventions; do not try to replace parts of the machine if
unauthorised. O.M.A.C. s.r.l. is not liable for damages to persons, animals or things deriving from unauthorised interventions.

7.1 List of spare parts and section drawings of the lobe displacement pump
Below the LDPU will be presented in its various sizes, complete with exploded view construction drawing and bill of materials table.
For each component, the tables below indicate the position in the exploded view drawing, the description, the needed amount and, depending on the
model, the item code to order as spare part.
In the “amounts” column there may be one or more values present: where there are two amounts, the value marked with the asterisk only refers to the
code marked with an asterisk, present on the same line, with reference to the pump model that one possesses.

AVVERTENZA
If, to replace spare parts, one needs to remove the front cover of the pump (pos. 44), it is essential to restore the pump hygiene level before putting it
back into service. It is reminded that in case the “B series lobe pump” has been configured for the treatment of alimentary products, level 1 hygiene must
be ensured.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 1
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.1 B100: Spare parts list


B100

7.1.1.1 B100: Pump exploded view drawing

O.M.A.C. s.r.l.
Chap.7 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.1.2 B100: Spare parts names and codes

B100
POS. DESCRIPTION Q.TY CODE POS. DESCRIPTION Q.TY CODE

1 BEARING BOX 1 2001G010 45 COVER O-RING 1 404T4337

2 GEAR COVER 1 2001L030 47 STUD 4 419A06X80

3 DRIVING SHAFT 1 2004B061 48 PIN 2 417A08X16

4 DRIVEN SHAFT 1 2004B062 50 O-RING 2 404T2050

5 FIXED GEAR 1 2008M013 51 CAP-NUT 4 414A06

6 ADJUSTABLE GEAR 1 2008M017 52 NUT 2 413A06

7 ADJUSTABLE GEAR BUSH 1 2008M038 55 PLANE WASHER 6 412F04

8 SCREW 6 410F04X10 56 BY-PASS SUPPORT 1 2013L019

9 SPLIT RING 2 421F37I 56/1 BUSH FOR SAFETY VALVE 1 2013B050

10 PLANE WASHER 4 412F06G17 57 PISTON FOR SAFETY VALVE 1 2013B057

11 AXIAL ADJUSTMENT SPACER 2 2014M030 58 COVER FOR SAFETY VALVE 1 2013L018

12 SCREW 4 411A06X30 59 ADJUSTMENT SCREW FOR SAFETY VALVE 1 2013B058

13 SCREW 4 411F06X12Z 60 THRUST WASHER 1 2013L017

15 GEAR COVER SEAL 1 404T3350 61 ADJUSTMENT RING NUT 1 2013A021

17 OIL SEAL RING 1 403Y18307D 62 BY PASS ADJUSTMENT RETAINER 1 2013L020

18 OIL SEAL RING 2 403Y25377D 63 SCREW 4 411A06X55

19 KEY 2 418F06X18 65 SCREW 2 420A05X06

20 KEY 1 418A06X30 66 SPLIT RING 1 421A025I

21 PIN 2 417A06X10 67 SPLIT RING 1 421A10E

23 GEAR RING NUT 2 415F20AUT 68 O-RING 1 404T4118

25 OIL VENT CAP 1 407L14S 69 O-RING 1 404T4150

26 OIL VENT CAP 1 407L14T 70 LOCK FOR SAFETY VALVE 1 411A05X05

27 OIL LEVEL 2 407L14L 71 SPRING 1 vedi par. 7.1.6

28 PLANE WASHER 4 407L14R 72 COVER FOR SAFETY VALVE 1 2006B025

29 FRONT BEARING 2 2019M020 80 HORIZONTAL FOOT 1 2001G100

30 REAR BEARING 2 406FNATB5904 81 SCREW FOR FOOT 4 411A06X10

40 ROTOR CASE 1 see par. 7.1.5 111 HEATED COVER 1 2006B058

41 316 S.S. GEAR ROTOR ST 2 2005B086 113 COVER JACKET 1 2006B167

41 316 S.S. 2-LOBE ST 2 2005B089 114 SCREW 4 411A06X16

41 RUBBER COATED 316 S.S. 5-LOBE 2 2005B098 115 O-RING 1 404T176

41 S.S. ANTI-SEIZURE ALLOY GEAR ROTOR 2 2005&086 239 SEAL PROTECTION 2 4034Y005

41 S.S. ANTI-SEIZURE ALLOY 2-LOBE 2 2005&089 302 SCREW 2 410A05X10

42 LOCKING NUT FOR ROTOR 2 2004B107 304 NAME PLATE 1 4034A100

43 O-RING 2 404T3075 305 RIVET 4 44301027

44 FRONT COVER 1 2006B007

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 3
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.1.3 B100: Seals section drawings


B100

UM LIP S1 LIP HN LIP

SINGLE MECH. “U7K”

POS. DESCRIPTION Q.TY CODE POS. DESCRIPTION Q.TY CODE

200 SEAL STOP PIN 2 2014B200 SEAL RING


240 2 402V35255
UM °VITON(F.K.M.)
201 MECHANICAL SEAL 2 4U020U7KXZ7 SEAL RING
240 2 402HN25357
AISI 316 L/CARBON/EPDM HN ELRING
201 MECH. SEAL AISI 316 L 2 4U020U7KXZY SEAL RING
/CARBON/F.K.M. 240 HN ELRING 2 402HN25357SPE
HEAT-SEALED
201 MECH. SEAL 7K-XFXZ5-HX 2 4U020U7KXZ5 241 SEAL RING BUSH 2 2004B170
201 MECH. SEAL 7K-X73Z7-HX 2 4U020U7K3Z7 242 BUSH O-RING 2 404T3081
201 MECH. SEAL 7K-XY3ZY-HX 2 4U020U7K3ZY 243 SECURITY DOWEL 6 420A05X05
201 MECH. SEAL 7K-XF3Z5-HX 2 4U020U7K3Z5 244 S1 SEAL RING 2 2014B058
PACKING GLAND
SUPPORT
201 MECH. SEAL 7K-X7337-HX 2 4U020U7K337 245 SCREW 4 410A06X12
201 MECH. SEAL 7K-XY33Y-HX 2 4U020U7K33Y 246 SCREW 4 410A06X14
201 MECH. SEAL 7K-XF335-HX 2 4U020U7K335 280 PTFE PACKING GLAND 1 205P25355
RING KIT
201 MECH. SEAL 7K-XYDKKY-HX 2 4U020U7KKKY 288 PACKING GLAND 2 2014B108
210 BALANCING RING 2 2014B015 289 SCREW 4 410A06X16
218 BALANCING RING SCREW 4 410A06X12 295 SPACER 2 2014B045

7.1.1.4 B100: Gasket or ring codes for mechanical seals


TUNGSTEN CARBIDE

TUNGSTEN CARBIDE
TUNGSTEN CARBIDE

TUNGSTEN CARBIDE
SILICON CARBIDE

SILICON CARBIDE
SILICON CARBIDE

SILICON CARBIDE

MECHANICAL
AISI 316 L

CERAMIC

CERAMIC

SEAL MATERIALS
CARBON

CARBON

CARBON

CARBON

RULON

B100

DIAMETER 20

U7K ROTATING
404U4081
RING O-RING
U7K STATIONARY
404U4112
RING O-RING

O.M.A.C. s.r.l.
Chap.7 - pag. 4 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.2 B105 B110 B115: Spare parts list

7.1.2.1 B105 B110 B115: Pump exploded view drawing

B105 B110 B115

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 5
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.2.2 B105 B110 B115: Spare parts names and codes


POS. DESCRIPTION Q.TY B105 B110 B115

1 BEARING BOX 1 2001G001


2 GEAR COVER 1 2001L031
3 AISI 316 L DRIVING SHAFT 1 2004B001 2004B002
3 DUPLEX DRIVING SHAFT 1 2004D001 2004D002
B105 B110 B115

3 AISI 316 L DOUBLE MECH. SEAL DRIVING SHAFT 1 2004D015 2004D016


4 AISI 316 L DRIVEN SHAFT 1 2004B029 2004B030
4 DUPLEX DRIVEN SHAFT 1 2004D029 2004D030
4 AISI 316 L DOUBLE MECH. SEAL DRIVING SHAFT 1 2004D045 2004D046
5 FIXED GEAR 1 2008M001
6 ADJUSTABLE GEAR 1 2008M007
7 ADJUSTABLE GEAR BUSH 1 2008M031
8 SCREW 6 411F05X14
9 SPLIT RING 2 2001C051
11 AXIAL ADJUSTMENT SPACER 2 2014M024
12 SCREW 4 411A06X16
13 PIN 2 417A06X15
14 SCREW 6 411A06X16S
15 GEAR COVER O-RING 1 404T4437
16 BEARING RETAINER O-RING 2 404T3218
17 OIL SEAL RING 1 403Y26377D
18 OIL SEAL RING 2 403Y35527D
19 KEY 2 418F08X30M
20 KEY 1 418F08X40
23 GEAR RING NUT 2 415F30
24 WASHER 2 416F30
25 OIL VENT CAP 1 407L14S+407L14R
26 OIL CAP 1 407L14T+407L14R
26/1 OIL CAP 1 407L38T+407L38R
27 OIL LEVEL 1 407L38L
28 HORIZONTAL FOOT 1 2001G101
29 FRONT BEARING (ASSEMBLED) 2 2019M001
31 VERTICAL FOOT 2 2001A301
32 SCREW FOR VERTICAL FOOT 8 411A08X20
33 COUNTERFLANGE FOR ENLARGED INLET PORT 1 - - 2006B045
34 O-RING 1 - - 404T3281
40 PUMPING CASE 1 see par. 7.1.5
41 3-LOBE ROTOR S.S.AISI 316 L VERSION ST 1 - 2005B002 2005B003
41 2-LOBE ROTOR S.S.AISI 316 L VERSION ST 2 - 2005B026 2005B027
41 3-LOBE ROTOR S.S.AISI 316 L VERSION SM 2 - 2005B014 2005B015
41 2-LOBE ROTOR S.S. AISI 316 L VERSION SM 2 - 2005B038 2005B039
41 RUBBER COATED 3-LOBE (5-LOBE FOR B105) BUNA-N.B.R. 2 2005B099 - -
41 RUBBER COATED 3-LOBE (5-LOBE FOR B105) E.P.D.M. 2 - 2005B050 2005B051
41 RUBBER COATED 2-LOBE ROTOR BUNA-N.B.R. 2 - - -
41 RUBBER COATED 2-LOBE E.P.D.M. 2 - - -
41 3-LOBE ROTOR CY5SnBIM (ANTISEIZURE) VERSION ST 2 - 2005&002 2005&003
41 DUAL WING CY5SnBIM (ANTISEIZURE) VERSION ST 2 2005&087 2005&074 2005&075
41 GEAR ROTOR S.S.AISI 316 L VERSION ST 2 2005B001 - -
41 GEAR ROTOR CY5SnBIM (ANTISEIZURE) VERSION ST 2 2005&001 - -
42 LOCKING NUT FOR STANDARD ROTOR 2 2004B101
43 LOCKING NUT O-RING 2 404T3100
44 FRONT COVER 2 2006B009 2006B001

O.M.A.C. s.r.l.
Chap.7- pag. 6 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS. DESCRIPTION Q.TY B105 B110 B115

45 COVER O-RING 2 404T4525


46 BACK STUD 4 419A08X33
47 FRONT STUD 4 419A08X33
48 BACK PIN 2 417A08X20
49 FRONT PIN 2 417A08X16

B105 B110 B115


50 ROTOR O-RING 2 404T2087
51 CAP NUT 4 414A08
52 CAP NUT 4 414A08
53 PLANE WASHER 4 412A08
55 PLANE WASHER 1 412F05
- COMPLETE SAFETY VALVE 1 2013B001
56 SAFETY VALVE SUPPORT 1 2013L021
56/1 BUSH SAFETY VALVE SUPPORT 1 2013B040
57 SAFETY VALVE PISTON 1 2013B025
58 SAFETY VALVE COVER 1 2013L029
59 SAFETY VALVE ADJUSTMENT SCREW 1 2013B031
60 THRUST WASHER 1 2013L032
61 ADJUSTMEN RING NUT 1 2013A034
62 SAFETY VALVE ADJUSTMENT RETAINER 1 2013L036
63 SAFETY VALVE SCREW 4 411A06X20
64 SAFETY VALVE COVER SCREW 4 411A06X55
65 SCREW 2 420A06X06
66 SPLIT RING (SEEGER) 1 421A38I
67 SPLIT RING (SEEGER) 1 421A16E
68 SAFETY VALVE PISTON O-RING 1 404T4200
69 SAFETY VALVE SUPPORT O-RING 1 404T3250
70 SAFETY VALVE LOCK 1 411A06X10
71 SPRING 1 see par 1.11.6
72 END COVER FOR SAFETY VALVE 1 2006B031
89 FOOT SCREW 4 411A08X20
91 SAFETY VALVE SUPPORT 1 2013B039
92 SCREW 4 411A06X35
93 SUPPORT O-RING 1 404T3250
94 PISTONE VALVOLA DI SICUREZZA PNEUMATICA 1 2013B029
95 KEY 1 418A14X30
96 SAFETY VALVE O-RING 1 404T4200
97 ADJUSTMENT RING NUT 1 2013A034
98 SCREW 2 420A05X06
99 PNEUMATIC SAFETY VALVE COVER 1 2013A032
100 PNEUMATIC SAFETY VALVE COVER BACK O-RING 1 404T4275
101 PNEUMATIC SAFETY VALVE COVER FRONT O-RING 1 404T4312
102 PISTON COVER O-RING 1 404T134
103 PNEUMATIC SAFETY VALVE JACKET 1 2013A035
104 SCREW 4 411A06X110
105 THRUST RING 1 2013L024
106 PISTON ROD THRUST O-RING 1 404T119
107 THRUST JACKET O-RING 1 404T6300
108 RING NUT 2 415F20AUT
111 END COVER FOR HEATING VERSION 1 2006B059 2006B051
112 END COVER FOR ASEPTIC VERSION 1 2006B101
113 END COVER FOR JACKET 1 2006B161
114 SCREW 4 411A06X116 411A06X20

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 7
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS. DESCRIPTION Q.TY B105 B110 B115

115 END COVER JACKET O-RING 1 404T4375


116 ASEPTIC INTERNAL COVER O-RING 1 404V3500
117 ASEPTIC EXTERNAL COVER O-RING 1 404V3550
118 COUNTERFLANGE FOR ASEPTIC VERSION PUMPING CASE 2 2006B181
B105 B110 B115

119 INTERNAL O-RING FOR ASEPTIC VERSION 2 404V3168


120 EXTERNAL O-RING FOR ASEPTIC VERSION 2 404V3231
121 SCREW 8 411A06X20
239 SEAL PROTECTION 2 4034Y001
302 SEAL PROTECTION SCREW 4 410A05X10
303 PLUG 4 44301020
304 NAME PLATE 1 4034A100
305 RIVET 4 44301027

7.1.2.3 B105 B110 B115: Seals section drawings


UM LIP S1 LIP PACKING GLAND

PACKING GLAND WITH LIQUID BARRIER SINGLE MECHANICAL SEAL


“U7K“ “KL2A“ “C5E“

SINGLE FLUSHED MECHANICAL SEAL


HN DOUBLE LIP “KL2A”, “U7K“, “C5E“ DOUBLE MECHANICAL SEAL

O.M.A.C. s.r.l.
Chap.7- pag. 8 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

B105 B110 B105 B110


POS. DESCRIPTION Q.TY POS. DESCRIPTION Q.TY
B115 B115

200 SEAL STOP PIN 2 2014B200 246 SCREW FOR HN LIP SEAL FLANGE 6 411A05X16
201 SINGLE MECHANICAL SEAL 2 see par. 7.1.2.6 247 PIN FOR HN LIP SEAL FLANGE 4 417A06X10
210 BALANCING RING 2 see par. 7.1.2.5 247 FOR UM LIP SEAL FLANGE 4 -
218 SCREW 6 410A05X10 280 KIT PACKING GLAND IN P.T.F.E. 1 205P38506

B105 B110 B115


220 FLUSHING SEAL BOX 2 2014B141 281 STUFFING BOX SEAL SUPPORT 2 2004B161
221 O-RING 2 404T3218 282 ROTATING BUSH O-RING 2 404T3118
222 SCREW 6 411A05X30 283 SCREW 6 420A05X05
223 SEAL RING UM 2 402V57486 284 STUFFING BOX SEAL SUPPORT 2 2014B071
224 ROTATING RING 2 2004B151 285 FLANGE SUPPORT O-RING 2 404T3218
225 BUSH O-RING 6 404T2137 286 SCREW 3 411A05X14
226 GRANO DI FISSAGGIO ANELLO ROTANTE 6 420A04X05 287 PIN 4 417A06X10
227 SPINA 4 417A06X10 288 PACKING GLAND ADJUSTER 2 2014B101
230 BALANCING RING U7K (SINGLE MECH. SEAL) 2 see par. 7.1.2.5 289 SCREW 2 410A05X16
BALANCING RING U7K KIT PACKING GLAND IN P.T.F.E. WITH LIQUID
231
(DOUBLE MECH. SEAL)
2 see par. 7.1.2.5 290
BARRIER
1 201P38506

232 O-RING 2 404T3218 291 FLUSHED STUFFING BOX SEAL SUPPORT 2 2014B077
233 SCREW 6 411A05X40 292 HYDRAULIC RING 2 2014B121
234 BEARING BOX FOR DOUBLE SEALS 1 2001G161 295 SPACER 2 -
235 FLUSHING BOX FOR DOUBLE SEAL 2 2014B147 296 MECHANICAL SEAL SUPPORT 2 -
236 COVER 2 2014B153 297 SUPPORT O-RING 2 -
237 SCREW 4 410A05X16 298 SCREW 4 -
238 O-RING 2 404T3218 299 PIN 2 430A05X10
239 SEAL PROTECTION 2 4034Y001 243 UM / S1 PIN 6 420A05X05
240 UM LIP SEAL IN °VITON (F.K.M.) 4 402V45356 243 HN PIN 6 420A05X05
240 UM LIP SEAL IN E.P.D.M. 4 402U45356 244 UM SUPPORT 2 2014B051
240 S1 LIP SEAL 2 402Q45357 244 S1 SUPPORT 2 2014B061
240 DOUBLE HN LIP SEAL 4 402HN40558 244 HN SUPPORT 2 2014B111
240 DOUBLE HN HEAT-SEALED 4 402HN40558SPE 245 UM O-RING SUPPORT 2 404T3218
241 ROTATING BUSH FOR UM / S1 LIP SEAL 2 2004B156 245 HN O-RING SUPPORT 2 404T3218
241 ROTATING BUSH FOR HN SEAL 2 2004B191 246 UM SUPPORTSCREW 6 411A05X14
242 BUSH O-RING FOR UM / S1 LIP SEAL 2 404T3118 246 S1 SUPPORT SCREW 6 411A05X10
242 BUSH O-RING FOR HN LIP SEAL 2 404T3118

7.1.2.4 B105 B110 B115: Gasket or ring codes for mechanical seals
TUNGST. CARB.

TUNGST. CARB.
TUNGST. CARB.

TUNGST. CARB.

MECHANICAL SEAL
SILICON CARB.

SILICON CARB.
SILICON CARB.

CARB. SILICIO
S.S.AISI 316 L

CERAMIC

CERAMIC
CARBON

CARBON

CARBON

CARBON

MATERIALS
RULON

B105 110 B115

DIAMETER 30

ROTATING O-RING 404U4118 404U4118 404U4118 404U4118


404U4118 404U4118 404U4118 -
U7K - KL2A - C5E (1) (2) (3) (3)

STATIONARY O-RING 404U4150 404U4150 404U4150 404U4150


404U4150 404U4150 404U4150 -
U7K - KL2A - C5E (1) (2) (3) (3)
(1)ONLY KL2A, C5E (2)ONLY C5E (3)ONLY KL2A

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 9
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.2.5 B105 B110 B115:Balancing ring codes for single and flushed mechanical seals

MECHANICAL SEAL MATERIAL STATIONARY RING B105 B110 B115


MATERIALS CODE RING MODEL
SINGLE SEAL FLUSHED SEAL

CARBON U7K 2014B001 2014B007


S.S. AISI 316 L
3 KL2A
CARBON S.S. AISI 316 L 2014B221 2014B231
B105 B110 B115

C5E
CARBON U7K
TUNGSTEN CARBIDE 2014B001 2014B007
4 TUNGSTEN CARBIDE KL2A
CARBON
TUNGSTEN CARBIDE C5E 2014B215 2014B241
U7K
TUNGSTEN CARBIDE TUNGSTEN CARBIDE 2014B001 2014B007
5 KL2A
TUNGSTEN CARBIDE
TUNGSTEN CARBIDE C5E 2014B215 2014B241
CERAMIC KL2A
6 CERAMIC 2014B221 2014B231
CARBON C5E
SILICON CARBIDE
A SILICON CARBIDE KL2A - -
CARBON
CERAMIC
7 CERAMIC C5E 2014B221 2014B231
RULON
SILICON CARBIDE
8 SILICON CARBIDE KL2A 2014B221 2014B231
SILICON CARBIDE
SILICON CARBIDE
9 TUNGSTEN CARBIDE KL2A 2014B001 2014B007
TUNGSTEN CARBIDE

7.1.2.6 B105 B110 B115: Single and double mechanical seals codes
COD. SEAL MATERIAL SEAL MODEL B105 B110 B115 COD. SEAL MATERIAL SEAL MODEL B105 B110 B115

U7K 4U030U7KXZ7 CERAMIC - CARBON


KL2A 4U030KL2AZCE
S.S. AISI 316 L O-RING IN E.P.D.M.
CARBON KL2A 4U030KL2AZYE C5E 4U030C5EBVE
O-RING IN EPDM
C5E 4U030C5EBGE CERAMIC - CARBON
KL2A 4U030KL2AZCV
O-RING IN °VITON
U7K 4U030U7KXZY C5E 4U030C5EBVV
S.S. AISI 316 L
3 CARBON KL2A 4U030KL2AZYV KL2A 4U030KL2AZCP
Q3 O-RING IN °VITON
CERAMIC - CARBON
6 O-RING IN P.T.F.E.
C5E 4U030C5EBGV C5E 4U030C5EBVP
U7K 4U030U7KXZP SILICON CARBIDE - CARBON
S.S. AISI 316 L O-RING IN E.P.D.M.
KL2A -
CARBON KL2A 4U030KL2AZYP
O-RING IN P.T.F.E. SILICON CARBIDE - CARBON
C5E 4U030C5EBGP O-RING IN °VITON
KL2A -
U7K 4U030U7K3Z7 SILICON CARBIDE - CARBON
TUNGSTEN CARB. KL2A -
O-RING IN P.T.F.E.
CARBON KL2A 4U030KL2AKZE
O-RING IN E.P.D.M. CERAMIC - RULON
C5E 4U030C5EBUE O-RING IN E.P.D.M.
C5E 4U030C5EYVE
U7K 4U030U7K3ZY CERAMIC -RULON
TUNGSTEN CARB. 7 O-RING IN °VITON
C5E 4U030C5EYVV
4 CARBON KL2A 4U030KL2AKZV
O-RING IN °VITON CERAMIC - RULON
C5E 4U030C5EBUV O-RING IN P.T.F.E.
C5E 4U030C5EYVP
U7K 4U030U7K3ZP SILICON CARBIDE
TUNGSTEN CARB. SILICON CARBIDE KL2A 4U030KL2AUUE
CARBON KL2A 4U030KL2AKZP O-RING IN E.P.D.M.
O-RING IN P.T.F.E.
C5E 4U030C5EBUP SILICON CARBIDE
8 SILICON CARBIDE KL2A 4U030KL2AUUV
U7K 4U030U7K337 O-RING IN °VITON
TUNGSTEN CARB.
TUNGSTEN CARB. KL2A 4U030KL2AKKE SILICON CARBIDE
O-RING IN E.P.D.M. SILICON CARBIDE KL2A 4U030KL2AUUP
C5E 4U030C5EUUE O-RING IN P.T.F.E.

U7K 4U030U7K33Y SILICON CARBIDE


TUNGSTEN CARB. TUNGSTEN CARBIDE KL2A 4U030KL2AUKE
5 TUNGSTEN CARB. KL2A 4U030KL2AKKV O-RING IN E.P.D.M.
Q5 O-RING IN °VITON SILICON CARBIDE
C5E 4U030C5EUUV 9 TUNGSTEN CARBIDE KL2A 4U030KL2AUKV
O-RING IN °VITON
U7K 4U030U7K33P
TUNGSTEN CARB. SILICON CARBIDE
TUNGSTEN CARB. KL2A 4U030KL2AKKP TUNGSTEN CARBIDE KL2A 4U030KL2AUKP
O-RING IN P.T.F.E. O-RING IN P.T.F.E.
C5E 4U030C5EUUP

O.M.A.C. s.r.l.
Chap.7- pag. 10 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.3 B215 B220 B325 B330 B390 B430 B440 B470 B490: Spare parts list

7.1.3.1 B215 B220 B325 B330 B390 B430 B440 B470 B490: Pump exploded view drawing

B2 B3 B4 B470 B490

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 11
E-mail:[email protected] SitoWeb:www.omacpompe.com
B2 B3 B4 B470 B490
POS DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

Chap.7 - pag. 12
1 BEARING BOX 1 2001G002 2001G003 2001G004 2001G008
2 GEAR COVER 1 2001L032 2001L033 2001L034 2001L038
3 AISI 316 L DRIVING SHAFT 1 2004B003 2004B004 2004B005 2004B006 2004B007 2004B008 2004B063 2004B065
3 DUPLEX DRIVING SHAFT 1 2004D003 2004D004 2004D005 2004D006 2004D007 2004D008 2004D009 2004D010
3 AISI 316 L DOUBLE MECH. SEAL DRIVING SHAFT 1 2004D017 2004D018 2004D019 2004D020 - 2004D021 2004D022 2004D023 2004D024
4 AISI 316 L DRIVEN SHAFT 1 2004B031 2004B032 2004B033 2004B034 2004B035 2004B036 2004B064 2004B066
4 DUPLEX DRIVEN SHAFT 1 2004D031 2004D032 2004D033 2004D034 2004D035 2004D036 2004D037 2004D038
4 AISI 316 L DOUBLE MECH. SEAL DRIVING SHAFT 1 2004D047 2004D048 2004D049 2004D050 - 2004D051 2004D052 2004D053 2004D054
5 FIXED GEAR 1 2008M002 2008M003 2008M004 2004M014
6 ADJUSTABLE GEAR 1 2008M008 2008M009 2008M010 2008M015
7 ADJUSTABLE GEAR BUSH 1 2008M032 2008M033 2008M034 2008M037
8 SCREW 6 411A06X16 411A08X20 411A10X25 411A10X30
9 SPLIT RING 2 2001C052 2001C053 2001C054 2001C057
10 REAR AXIAL ADJUSTMENT SPACER 2 2014M021 - - - - - - -
11 FRONT AXIAL ADJUSTMENT SPACER 2 2014M025 2014M026 2014M027 2014M044
12 SCREW 4 411A08X20 411A08X25 411A10X30 411A10X30
13 PIN 2 417A06X14 417A06X16 417A06X16 417A08X16

Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy


14 SCREW 6

O.M.A.C. s.r.l.
411A08X20S 411A08X20S 411A10X25S 411A10X25S
15 GEAR COVER O-RING 1 404T4562 404T4675 404T4900 404T81050
16 BEARING RETAINER O-RING 2 404T3268 404T4312 404T4437 404T4500
17 OIL SEAL RING 1 403Y32457 403Y37528 403Y557210D 403Y658510D
18 OIL SEAL RING 2 403Y45608D 403Y60758D 403Y801008D 403Y9011012D
19 KEY 2 418F10X30M 418F12X40M 418F18X50M 418F20X60M

E-mail:[email protected] SitoWeb:www.omacpompe.com
20 KEY 1 418F08X40 418F10X50 418F14X70 418F16X90
21 BEARING RING NUT 2 415F40 415F50 415F70 415F80
22 WASHER 2 416F40 416F50 416F70 416F80

Tel.0522/629371 - 629923 Fax 0522/628980


23 GEAR RING NUT 2 415F35 415F40 415F60 415F70
24 WASHER 2 416F35 416F40 416F60 416F70
7.1.3.2 B215 B220 B325 B330 B390 B430 B440 B470 B490: Spare parts names and codes

25 OIL VENT CAP 1 407L12S 407L12S 407L12S 407L12S


26 OIL CAP 1 407L12T 407L12T 407L12T 407L12T
27 OIL LEVEL 1 407L12L 407L12L 407L12L 407L12L
Rev.4 del 01/2010 O.M.A.C. s.r.l.

28 HORIZONTAL FOOT 1 2001G102 2001G103 2001G104 2001G105


29 FRONT BEARING (ASSEMBLED) 2 2019M002 2019M003 2019M004 2019M008
30 REAR BEARING (ASSEMBLED) 2 2019M005 2019M002 2019M007 2019M004
POS DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

31 VERTICAL FOOT 2 2001A302 2001A303 2001A304 2001A305


32 SCREW FOR VERTICAL FOOT 8 411A10X20 411A12X25 411A14X30 411A20X40
33 COUNTERFLANGE FOR ENLARGED INLET PORT 1 - 2006B046 - 2006B047 - - 2006B048 - 2006B049
34 O-RING 1 - 404T4350 - 404T4500 - - 404T4650 - 404T4725
40 PUMPING CASE 1 23....04 23....05 23....06 23....07 23....17 23....08 23....09 23....15 23....16
41 3-LOBE ROTOR S.S. AISI 316 L VERSIONE ST 1 2005B004 2005B005 2005B006 2005B007 2005B096 2005B008 2005B009 2005B090 2005B092
41 2-LOBE S.S. AISI 316 L VERSION ST 2 2005B028 2005B029 2005B030 2005B031 - 2005B032 2005B033 2005B094 2005B095
41 3-LOBE ROTOR S.S. AISI 316 L VERSIONE SM 2 2005B016 2005B017 2005B018 2005B019 - 2005B020 2005B021 2005B046 2005B047
Rev.4 del 01/2010 O.M.A.C. s.r.l.

41 2-LOBE S.S. AISI 316 L VERSION SM 2 2005B040 2005B041 2005B042 2005B043 - 2005B044 2005B045 2005B048 2005B049
3-LOBE ROTOR (5-LOBE FOR B105)
41 2 2005B052 2005B053 2005B054 2005B055 - 2005B056 2005B057 - -
RUBBER COATED N.B.R.
3-LOBE ROTOR (5-LOBE FOR B105)
41 2 - - - - - - - - -
RUBBER COATED E.P.D.M.

41 2-LOBE ROTOR RUBBER COATED N.B.R. 2 2005B064 2005B065 2005B066 2005B067 - 2005B068 2005B069 2005B096 2005B097
41 2-LOBE ROTOR RUBBER COATED E.P.D.M. 2 - - - - - - - - -
41 DUAL WING CY5SnBIM (antiseizure) VERSION ST 2 2005&076 2005&77 2005&078 2005&079 - 2005&080 2005&081 2005&082 2005&083
41 3-LOBE ROTOR CY5SnBIM (antiseizure) VERSION ST 2 2005&004 2005&005 2005&006 2005&007 - 2005&008 2005&009 - -
42 LOCKING NUT FOR STANDARD ROTOR 2 2004B102 2004B103 2004B125 2004B104 2004B104
43 LOCKING NUT O-RING 2

Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy


404T3118 404T3162 404T3162 404T3200 404T3200

O.M.A.C. s.r.l.
44 FRONT COVER 2 2006B002 2006B003 2006B004 2006B008
45 COVER O-RING 2 404T4625 404T4750 404T81025 404T81175
46 BACK STUD 4 419A10X41 419A12X46 419A16X55 419A20X70
47 FRONT STUD 4(*)-8 419A10X41(*) 419A10X41 419A12X46 419A14X55
48 BACK PIN 2 417A10X20 417A12X25 417A12X25 417A16X40
49 FRONT PIN 2 417A08X16 417A08X16 417A08X16 417A10X20

E-mail:[email protected] SitoWeb:www.omacpompe.com
50 ROTOR O-RING 2 404T2106 404T3143 4043187 407T3187
51 CAP NUT 4(*)-8 414A10(*) 414A10 414A12 414A14
52 CAP NUT 4 414A10 414A12 414A16 414A20

Tel.0522/629371 - 629923 Fax 0522/628980


53 PLANE WASHER 4 412A10 412A12 412A16 412A20
55 PLANE WASHER 12 412F06 412F08 412F10 412F10
- COMPLETE SAFETY VALVE 6 2013B002 2013B003 2013B004 2013B021
56 SAFETY VALVE SUPPORT 1 2013L021 2013L022 2013L023 2013B047
56/1 BUSH SAFETY VALVE SUPPORT 1 2013B040 2013B041 2013B042 2013B042
57 SAFETY VALVE PISTON 1 2013B026 2013B027 2013B028 2013B048

Chap.7 - pag. 13
B2 B3 B4 B470 B490
B2 B3 B4 B470 B490
POS DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

Chap.7 - pag. 14
58 SAFETY VALVE COVER 1 2013L029 2013L029 2013L030 2013A027
59 SAFETY VALVE ADJUSTMENT SCREW 1 2013B031 2013B031 2013B031 2013A028
60 THRUST WASHER 1 2013L032 2013L032 2013L033 2013A026
61 ADJUSTMEN RING NUT 1 2013A034 2013A034 2013A035 2013A038
62 SAFETY VALVE ADJUSTMENT RETAINER 1 2013L036 2013L036 2013L036 2013A025
63 SAFETY VALVE SCREW 1 411A06X20 411A08X35 411A10X40 411A08X50
64 SAFETY VALVE COVER SCREW 4 411A06X55 411A06X55 411A08X60 411A08X70
65 SCREW 4 420A06X06 420A06X06 420A06X06 420A06X06
66 SPLIT RING (SEEGER) 2 421A38I 421A38I 421A52I 421A63I
67 SPLIT RING (SEEGER) 1 421A16E 421A16E 421A16E 421A34E
68 SAFETY VALVE PISTON O-RING 1 404T4200 404T6275 404T189 404T208
69 SAFETY VALVE SUPPORT O-RING 1 404T3250 404T4337 404T4462 404T4600
70 SAFETY VALVE LOCK 1 41106X10 411A06X10 411A06X10 418A20X56
71 SPRING 1 see par. 7.1.6
72 END COVER FOR SAFETY VALVE 1 2006B032 2006B033 2006B034 2006B029
89 FOOT SCREW 4 411A10X25 411A12X35 411A14X35 411A20X50
91 SAFETY VALVE SUPPORT 1 2013B039 2013B032 2013B036 2013B043

Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy


92 SCREW 4

O.M.A.C. s.r.l.
411A06X35 411A08X40 411A10X40 411A08X40
93 SUPPORT O-RING 1 404T3250 404T4337 404T4462 404T4600
94 PISTONE VALVOLA DI SICUREZZA PNEUMATICA 1 2013B030 2013B035 2013B038 2013B045
95 KEY 1 418A14X30 418A14X30 418A14X30 418A18X50
96 SAFETY VALVE O-RING 1 404T4200 404T6275 404T189 404T208
97 ADJUSTMENT RING NUT 1 2013A034 2013A034 2013A034 2013A038

E-mail:[email protected] SitoWeb:www.omacpompe.com
98 SCREW 2 420A05X06 420A05X06 420A05X06 420A06X08
99 PNEUMATIC SAFETY VALVE COVER 1 2013A032 2013A030 2013A031 2013A029
100 PNEUMATIC SAFETY VALVE COVER BACK O-RING 1 404T4275 404T4275 404T4312 404T4425

Tel.0522/629371 - 629923 Fax 0522/628980


101 PNEUM. SAFETY VALVE COVER FRONT O-RING 1 404T4312 404T4312 404T4475 404T4600
102 PISTON COVER O-RING 1 404T134 404T134 404T134 404T4131
103 PNEUMATIC SAFETY VALVE JACKET 1 2013A035 2013A036 2013A037 2013A039
104 SCREW 4-6(*) 411A06X110 411A08X130 411A10X130 411A08X130(*)
105 THRUST RING 1 2013L024 2013L024 2013L025 2013L026
Rev.4 del 01/2010 O.M.A.C. s.r.l.

106 PISTON ROD THRUST O-RING 1 404T119 404T119 404T119 404T4075


107 THRUST JACKET O-RING 1 404T6300 404T6300 404T8450 404T8562
108 RING NUT 2 415F20AUT 415F20AUT 415F20AUT 415F25AUT
POS DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

111 END COVER FOR HEATING VERSION 1 2006B052 2006B053 2006B054 2006B057
112 END COVER FOR ASEPTIC VERSION 1 2006B102 2006B103 2006B104 2006B105
113 END COVER FOR JACKET 1 2006B162 2006B162 2006B164 2006B168
114 SCREW 4-6(*) 411A06X20 411A06X20 411A06X20 411A06X20 (*) 411A08X25(*)
115 END COVER JACKET O-RING 1 404T4500 404T4500 404T4750 404T4875
116 ASEPTIC INTERNAL COVER O-RING 1 404V4625 404V4750 404V009 404T81150
117 ASEPTIC EXTERNAL COVER O-RING 1 404V4675 404V4825 404V010 404T81250
COUNTERFLANGE FOR ASEPTIC
118 2 2006B181 2006B182 2006B183 2006B184 2006B184 2006B185 2006B185
Rev.4 del 01/2010 O.M.A.C. s.r.l.

VERSION PUMPING CASE

119 INTERNAL O-RING FOR ASEPTIC VERSION 2 404V3168 404V3212 404V174 404V4325 404V4325 404V4426 404V4426
120 EXTERNAL O-RING FOR ASEPTIC VERSION 2 404V3231 404V3275 404V4350 404V4412 404V4412 404V4525 404V4525
8
121 SCREW 12(*) 411A06X20 411A06X20(*) 411A08X25(*) 411A08X25(*) 411A08X35(**) 411A10X35(**)
16(**)

239 SEAL PROTECTION 2 4034Y002 4034Y003 4034Y004 4034Y007


302 SEAL PROTECTION SCREW 4 410A05X10 410A05X10 410A05X10 410A05X10
303 PLUG 4 44301022 44301023 44301024 44301025
304 NAME PLATE 1 4034A100 4034A100 4034A100 4034A100
305 RIVET 4 44301027 44301027 44301027 44301027

Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy


306 EYEBOLT 2 - - - - - - - - -

O.M.A.C. s.r.l.

E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.7 - pag. 15 Tel.0522/629371 - 629923 Fax 0522/628980
B2 B3 B4 B470 B490
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.3.3 B215 B220 B325 B330 B390 B430 B440 B470 B490: Seals section drawings

UM Lip Seal S1 Lip Seal Packing Gland

Packing Gland Single Mechanical Seal


with liquid barrier “U7K“ “KL2A“ “C5E“
B2 B3 B4 B470 B490

Single Flushed Mechanical Seal


Double HN Lip Seal FLUSSATA “KL2A”, “U7K“, “C5E“ Double Mechanical Seal

POS. DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

200 SEAL STOP PIN 2 2014B200 2014B200 2014B200 2014B200


201 SINGLE MECHANICAL SEAL 2 see par. 7.1.3.6
210 BALANCING RING 2 see par. 7.1.3.5
218 SCREW 6 - 8(*) 410A06X12 410A06X14 410A10X20 410A10X20(*)
220 FLUSHING SEAL BOX 2 2014B142 2014B143 2014B144 2014B159
221 O-RING 2 404T168 404T4312 404T4437 404T4500
222 SCREW 6 - 8(*) 411A06X35 411A06X40 411A10X40 411A10X50(*)
223 SEAL RING UM 2 402V705510 402V857010 402V1109510 402V13511012
O.M.A.C. s.r.l.
Chap.7 - pag. 16 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS. DESCRIPTION Q.TY B215 B220 B325 B330 B390 B430 B440 B470 B490

224 ROTATING RING 2 2004B152 2004B153 2004B154 2004B167


225 BUSH O-RING 6 404T3181 404T4237 404T4312 404T4350
226 GRANO DI FISSAGGIO ANELLO ROTANTE 6 420A05X05 420A05X05 420A06X06 420A06X08
227 SPINA 4 417A06X12 417A06X12 417A08X15 417A08X15
230 BALANCING RING U7K (SINGLE MECH. SEAL) 2 see par. 7.1.3.6
BALANCING RING U7K
231
(DOUBLE MECH. SEAL)
2 see par. 7.1.3.5

232 O-RING 2 404T168 404T4312 404T4437 -


233 SCREW 6 - 8(*) 411A06X40 411A06X50 411A10X45 411A10X55
234 BEARING BOX FOR DOUBLE SEALS 1 2001G162 2001G163 2001G164 2001G165
235 FLUSHING BOX FOR DOUBLE SEAL 2 2014B148 2014B149 2014B150 2014B151
236 COVER 2 2014B154 2014B155 2014B156 2014B157
237 SCREW 4 410A06X18 410A06X16 410A10X20 410A10X20
238 O-RING 2 404T165 404T4312 404T4412 404T4500
239 SEAL PROTECTION 2 4034Y002 4034Y003 4034Y004 4034A007
240 UM LIP SEAL IN °VITON (F.K.M.) 4 402V48405 402V705510 402V857010 402V1058510
240 UM LIP SEAL IN E.P.D.M. 4 402U48405 402U705510 402U857010 402U1058510
240 S1 LIP SEAL 2 402Q48406 402Q70558 402Q857010 402Q1158510
240 DOUBLE HN LIP SEAL 4 402HN42608 402HN55728 402HN8010010 402HN85X110X10
241 ROTATING BUSH FOR UM / S1 LIP SEAL 2 2004B157 2004B158 2004B159 2004B168
241 ROTATING BUSH FOR HN SEAL 2 2004B192 2004B193 2004B194 2004B198

B2 B3 B4 B470 B490
242 BUSH O-RING FOR UM / S1 LIP SEAL 2 404T3137 404T4200 404T168 404T181
242 BUSH O-RING FOR HN LIP SEAL 2 404T149 404T4237 404T168 404T181
243 UM / S1 PIN 6 420A06X06 420A06X06 420A06X06 420A08X10
243 HN PIN 6 420A05X05 420A05X05 420A06X06 420A08X10
244 UM SUPPORT 2 2014B052 2014B053 2014B054 2014B057
244 S1 SUPPORT 2 2014B062 2014B063 2014B064 2014B066
244 HN SUPPORT 2 2014B112 2014B113 2014B114 2014B116
245 UM O-RING SUPPORT 2 404T168 404T4312 404T4437 404T4500
245 HN O-RING SUPPORT 2 404T168 404T4312 404T4437 404T4500
246 UM SUPPORTSCREW 6 410A06X12 41006X25 410A10X25 410A10X30
246 S1 SUPPORT SCREW 6 410A06X12 410A06X14 410A10X25 410A10X16
246 SCREW FOR HN LIP SEAL FLANGE 6 410A06X20 410A06X20 410A10X25 410A10X25
247 PIN FOR HN LIP SEAL FLANGE 4 417A06X12 417A06X16 417A08X16 417A08X16
247 FOR UM LIP SEAL FLANGE 4 - 417A06X16 417A08X15 417A08X16
280 KIT PACKING GLAND IN P.T.F.E. 1 205P45576 205P60768 205P80968 205P10012010
281 STUFFING BOX SEAL SUPPORT 2 2004B162 2004B163 2004B164 2004B169
282 ROTATING BUSH O-RING 2 404T4137 404T4200 404T168 404T181
283 SCREW 6 420A06X05 420A06X06 420A06X06 420A08X08
284 STUFFING BOX SEAL SUPPORT 2 2014B072 2014B073 2014B074 2014B083
285 FLANGE SUPPORT O-RING 2 404T168 404T4312 404T4437 404T4500
286 SCREW 3 411A06X16 411A06X20 411A10X16 411A10X25
287 PIN 4 417A06X12 417A06X12 417A08X16 417A08X16
288 PACKING GLAND ADJUSTER 2 2014B102 2014B103 2014B104 2014B107
289 SCREW 2 410A06X20 410A08X20 410A10X25 410A10X25
290 KIT PACKING GLAND IN P.T.F.E. WITH LIQUID BARRIER 1 201P45576 201P60768 201P80968 201P10012010
291 FLUSHED STUFFING BOX SEAL SUPPORT 2 2014B078 2014B079 2014B080 2014B084
292 HYDRAULIC RING 2 2014B122 2014B123 2014B124 2014B126
295 SPACER 2 - - - -
296 MECHANICAL SEAL SUPPORT 2 - - - -
297 SUPPORT O-RING 2 - - - -
298 SCREW 4 - - - -
299 PIN 2 430A05X10 430A06X12 430A08X18 430A08X20

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 17
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.3.4 B215 B220 B325 B330 B390 B430 B470 B490: Gasket or ring codes for mechanical seals
MECHANICAL SEAL B215 B220 B325 B330 B390 B430 B440 B470 B490
RING TYPE RING MODEL
MATERIALS DIAMETER 35 DIAMETER 50 DIAMETER 65 DIAMETER 80

U7K 404U6262 404U181


ROTANTING KL2A 404U4137 404U4200 404U65X4.5 404U80X4.5

S.S. AISI 316 L C5E 404U168 404U181


CARBON U7K 404U6237 404U6300 404U92X7
STATIONARY KL2A 404U147 404U93X6
404U61X4.65 404U76X4.65
C5E 404U94X6
U7K 404U6262 404U181
ROTANTING KL2A 404U4137 404U4200 404U65X4.5 404U80X4.5

TUNGSTEN CARBIDE C5E 404U168 -


CARBON U7K 404U92X7
404U6237 404U6300
STATIONARY KL2A 404U147 404U93X6
C5E 404U61X4.65 404U76X4.65 -
U7K 404U6262 404U181
ROTANTING KL2A 404U4137 404U4200 404U65X4.5 404U93X6

TUNGSTEN CARBIDE C5E 404U168 -


TUNGSTEN CARBIDE U7K 404U92X7
404U6237 404U6300
STATIONARY KL2A 404U147 904U93X6
C5E 404U61X4.65 404U76X4.65 -
KL2A - -
404U4137 404U4200
B2 B3 B4 B470 B490

ROTANTING
CERAMIC C5E 404U168 404U181
CARBON KL2A - -
STATIONARY 404U147 404U61X4.65
C5E 404U76X4.65 404U94X6

SILICON CARBIDE ROTANTING - - 404U65X4.5 404U80X4.5


KL2A
CARBON STATIONARY - - 404U76X4.65 404U93X6

CERAMIC ROTANTING 404U4137 404U4200 404U168 404U181


C5E
RULON STATIONARY 404U147 404U61X4.65 404U76X4.65 404U94X6

SILICON CARBIDE ROTANTING 404U4137 404U4200 404U65X4.5 404U80X4.5


KL2A
SILICON CARBIDE STATIONARY 404U147 404U61X4.65 404U76X4.65 404U93X6

SILICON CARBIDE ROTANTING 404U4137 404U4200 404U65X4.5 404U80X4.5


KL2A
TUNGSTEN CARBIDE STATIONARY 404U147 404U6237 404U6300 404U93X6

7.1.3.5 B215 B220 B325 B330 B390 B430 B470 B490: Balancing ring codes for single and flushed
mechanical seals
B215 B220 B325 B330 B390 B430 B440 B470 B490
MECHANICAL MATERIAL STATIONARY RING
SEAL MATERIAL CODE RING MODEL SINGLE FLUSHED SINGLE FLUSHED SINGLE FLUSHED SINGLE FLUSHED
SEAL SEAL SEAL SEAL SEAL SEAL SEAL SEAL

CARBON U7K 2014B002 2014B008 2014B003 2014B009 2014B004 2014B010 2014B018 2014B019
S.S. AISI 316 L
CARBON
3 S.S.AISI316L KL2A
2014B222 2014B232 2014B223 2014B233 2014B224 2014B234 2014B236 2014B237
S.S.AISI316L C5E
CARBON U7K
TUNGST. CARB. 2014B002 2014B008 2014B003 2014B009 2014B004 2014B010 2014B018 2014B019
CARBON
4 TUNGST.CARBIDE KL2A

TUNGST.CARBIDE C5E 2014B216 2014B242 2014B217 2014B243 2014B218 2014B244 - -


TUNGST.CARBIDE U7K
TUNGST. CARB. 2014B002 2014B008 2014B003 2014B009 2014B004 2014B010 2014B018 2014B019
TUNGST. CARB.
5 TUNGST.CARBIDE KL2A

TUNGST.CARBIDE C5E 2014B216 2014B242 2014B217 2014B243 2014B218 2014B244 - -

CERAMIC KL2A - - - -
CARBON
6 CERAMIC 2014B222 2014B232 2014B223 2014B233
C5E 2014B224 2014B234 2014B236 2014B237
SILICON CARB.
CARBON
A SILICONCARBID KL2A - - - - 2014B224 2014B234 2014B236 2014B237

CERAMIC
RULON
7 CERAMICA C5E 2014B222 2014B232 2014B223 2014B233 2014B224 2014B234 - -

SILICON CARB.
SILICON CARB.
8 SILICONCARBID KL2A 2014B222 2014B232 2014B223 2014B233 2014B224 2014B234 2014B236 2014B237

SILICON CARB.
TUNGST. CARB.
9 TUNGST.CARBIDE KL2A 2014B002 2014B008 2014B003 2014B009 2014B004 2014B010 2014B018 2014B019

O.M.A.C. s.r.l.
Chap.7 - pag. 18 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.3.6 B215 B220 B325 B330 B390 B430 B470 B490: Single and double mechanical seals codes
COD. SEAL MATERIAL SEAL MODEL B215 B220 B325 B330 B390 B430 B440 B470 B490

U7K 4U035U7KXZ7 4U050U7KXZ7 4U065U7KXZ7 4U080U7KXZ7


S.S. AISI 316 L / CARBON
O-RING IN EPDM
KL2A 4U035KL2AXZY 4U050KL2AXZY 4U065KL2AXZY 4U080KL2AXZY
C5E 4U035C5EBGE 4U050C5EBGE 4U065C5EBGE 4U080C5EBGE
U7K 4U035U7KXZY 4U050U7KXZY 4U065U7KXZY 4U080U7KXZY
3 S.S. AISI 316 L / CARBON
Q3 O-RING IN °VITON
KL2A 4U035KL2AZYV 4U050KL2AZYV 4U065KL2AZYV 4U080KL2AZYV
C5E 4U035C5EBGV 4U050C5EBGV 4U065C5EBGV 4U080C5EBGV
U7K 4U035U7KXZP 4U050U7KXZP 4U065U7KXZP 4U080U7KXZP
S.S. AISI 316 L / CARBON
O-RING IN P.T.F.E.
KL2A 4U035KL2AZYP 4U050KL2AZYP 4U065KL2AZYP 4U080KL2AZYP
C5E 4U035C5EBGP 4U050C5EBGP 4U065C5EBGP 4U080C5EBGP
U7K 4U035U7K3Z7 4U050U7K3Z7 4U065U7K3Z7 4U080U7K3Z7
TUNGSTEN CARBIDE / CARBON
O-RING IN E.P.D.M.
KL2A 4U035KL2AKZE 4U050KL2AKZE 4U065KL2AKZE 4U080KL2AKZE
C5E 4U035C5EBUE 4U050C5EBUE 4U065C5EBUE -
U7K 4U035U7K3ZY 4U050U7K3ZY 4U065U7K3ZY 4U080U7K3ZY
TUNGSTEN CARBIDE / CARBON
4 O-RING IN °VITON
KL2A 4U035KL2AKZV 4U050KL2AKZV 4U065KL2AKZV 4U080KL2AKZV
C5E 4U035C5EBUV 4U050C5EBUV 4U065C5EBUV -
U7K 4U035U7K3ZP 4U050U7K3ZP 4U065U7K3ZP 4U080U7K3ZP
TUNGSTEN CARBIDE / CARBON
O-RING IN P.T.F.E.
KL2A 4U035KL2AKZP 4U050KL2AKZP 4U065KL2AKZP 4U080KL2AKZP
C5E 4U035C5EBUP 4U050C5EBUP 4U065C5EBUP -
U7K 4U035U7K337 4U050U7K337 4U065U7K337 4U080U7K337
TUNGSTEN CARBIDE / TUNGSTEN CARBIDE

B2 B3 B4 B470 B490
O-RING IN E.P.D.M.
KL2A 4U035KL2AKKE 4U050KL2AKKE 4U065KL2AKKE 4U080KL2AKKE
C5E 4U035C5EUUE 4U050C5EUUE 4U065C5EUUE -
U7K 4U035U7K33Y 4U050U7K33Y 4U065U7K33Y 4U080U7K33Y
5 TUNGSTEN CARBIDE / TUNGSTEN CARBIDE
KL2A 4U035KL2AKKV 4U050KL2AKKV 4U065KL2AKKV 4U080KL2AKKV
Q5 O-RING IN °VITON
C5E 4U035C5EUUV 4U050C5EUUV 4U065C5EUUV -
U7K 4U035U7K33P 4U050U7K33P 4U065U7K33P 4U080U7K33P
TUNGSTEN CARBIDE / TUNGSTEN CARBIDE
O-RING IN P.T.F.E.
KL2A 4U035KL2AKKP 4U050KL2AKKP 4U065KL2AKKP 4U080KL2AKKP
C5E 4U035C5EUUP 4U050C5EUUP 4U065C5EUUP -

CERAMIC / CARBON KL2A 4U035KL2AZCE 4U050KL2AZCE - -


O-RING IN E.P.D.M. C5E 4U035C5EBVE 4U050C5EBVE 4U065C5EBVE 4U080C5EBVE
CERAMIC KL2A 4U035KL2AZCV 4U050KL2AZCV - -
CARBON
O-RING IN °VITON C5E 4U035C5EBVV 4U050C5EBVV 4U065C5EBVV 4U080C5EBVV
CERAMICA KL2A 4U035KL2AZCP 4U050KL2AZCP - -
CARBON
6
O-RING IN P.T.F.E. C5E 4U035C5EBVP 4U050C5EBVP 4U065C5EBVP 4U080C5EBVP
SILICON CARBIDE / CARBON
O-RING IN E.P.D.M.
KL2A - - 4U065KL2AZUE 4U080KL2AZUE

SILICON CARBIDE / CARBON


O-RING IN °VITON
KL2A - - 4U065KL2AZUV 4U080KL2AZUV

SILICON CARBIDE / CARBON


O-RING IN P.T.F.E.
KL2A - - 4U065KL2AZUP 4U080KL2AZUP

CERAMIC / RULON
O-RING IN E.P.D.M.
C5E 4U035C5EYVE 4U050C5EYVE 4U065C5EYVE -

CERAMIC / RULON
7 O-RING IN °VITON
C5E 4U035C5EYVV 4U050C5EYVV 4U065C5EYVV -

CERAMIC / RULON
O-RING IN P.T.F.E.
C5E 4U035C5EYVP 4U050C5EYVP 4U065C5EYVP -

SILICON CARBIDE / SILICON CARBIDE


O-RING IN E.P.D.M.
KL2A 4U035KL2AUUE 4U050KL2AUUE 4U065KL2AUUE 4U080KL2AUUE

SILICON CARBIDE / SILICON CARBIDE


8 O-RING IN °VITON
KL2A 4U035KL2AUUV 4U050KL2AUUV 4U065KL2AUUV 4U080KL2AUUV

SILICON CARBIDE / SILICON CARBIDE


O-RING IN P.T.F.E.
KL2A 4U035KL2AUUP 4U050KL2AUUP 4U065KL2AUUP 4U080KL2AUUP

SILICON CARBIDE / TUNGSTEN CARBIDE


O-RING IN E.P.D.M.
KL2A 4U035KL2AUKE 4U050KL2AUKE 4U065KL2AUKE 4U080KL2AUKE
SILICON CARBIDE / TUNGSTEN CARBIDE
9 O-RING IN °VITON
KL2A 4U035KL2AUKV 4U050KL2AUKV 4U065KL2AUKV 4U080KL2AUKV
SILICON CARBIDE / TUNGSTEN CARBIDE
O-RING IN P.T.F.E.
KL2A 4U035KL2AUKP 4U050KL2AUKP 4U065KL2AUKP 4U080KL2AUKP

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 19
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.4 B550 B660 B680: Spare parts list

7.1.4.1 B550 B660 B680: Pump exploded view drawing

B550 Exploded view drawing


B550 B660 B680

O.M.A.C. s.r.l.
Chap.7 - pag. 20 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

B660 B680 Exploded view drawing

B550 B660 B680

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 21
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.4.2 B550 B660 B680: Spare parts names and codes


POS DESCRIPTION Q.TY B550 B660 B680

1 BEARING BOX 1 2001G005 2001G006


2 GEAR COVER 1 2001G035 2001G036
3 AISI 316 L DRIVING SHAFT 1 2004B010 2004B011 2004B012
3 DUPLEX DRIVING SHAFT 1 - 2004D011 -
4 AISI 316 L DRIVEN SHAFT 1 2004B038 2004B039 2004B040
4 DUPLEX DRIVEN SHAFT 1 - 2004D039
5 FIXED GEAR 1 2008M005 2008M006
6 ADJUSTABLE GEAR 1 2008M011 2008M012
7 ADJUSTABLE GEAR BUSH 1 2008035 2008M036
8 SCREW 6 410A12X35 410A16X45
9 SPLIT RING 2 2001C055 2001C056
10 2 2014M022 2014M023
11 AXIAL ADJUSTMENT SPACER 8 2014M028 2014M029
12 SCREW 4 411A08X20 411A10X30
13 PIN 2 417A08X16 417A10X30
14 SCREW 6 411A08X20 411A10X30
15 GEAR COVER O-RING 1 404T001 404T002
16 BEARING RETAINER O-RING 2 404T4562 404T4875
17 OIL SEAL RING 1 403Y609010 403Y9012012
18 OIL SEAL RING 2 403Y8011010D 403Y12015012D
19 KEY 2 418F20X60M 418F28X80M
20 KEY 1 418F16X90 418F22X120
23 GEAR RING NUT 2 415F70 415F100
24 WASHER 2 416F70 416F100
25 OIL VENT CAP 1 407L12S 407L12S
26 OIL CAP 1 407L38T 407L12T
27 OIL LEVEL 1 407L34L 407L1L
29 FRONT BEARING (ASSEMBLED) 2 406FNJ2216E 406FNJ224
30 REAR BEARING (ASSEMBLED) 2 406F3214 406F3220
40 PUMPING CASE 1 23....11 23....12 23....13
41 3-LOBE ROTOR S.S.AISI 316 L VERSION ST 2 2005B011 2005B012 2005B013
41 2-LOBE ROTOR S.S.AISI 316 L VERSION ST 2 2005B035 2005B036 2005B037
41 3-LOBE ROTOR S.S.AISI 316 L VERSION SM 2 2005B023 2005B024 2005B025
41 2-LOBE ROTOR S.S. AISI 316 L VERSION SM 2 2005B102 2005B048 2005B049
41 RUBBER COATED 3-LOBE ROTOR BUNA-N.B.R. 2 2005B059 2005B060 2005B061
41 RUBBER COATED 3-LOBE ROTOR E.P.D.M. 2 2005B071 2005B072 2005B073
41 RUBBER COATED 2-LOBE ROTOR BUNA-N.B.R. 2 - - -
41 RUBBER COATED 2-LOBE ROTOR E.P.D.M. 2 - - -
41 DUAL WING CY5SnBIM (ANTISEIZURE) VERSION ST 2 2005&084 2005&085 -
B550 B660 B680

41 3-LOBE ROTOR CY5SnBIM (ANTISEIZURE) VERSION ST 2 2005&011 2005&012 2005&013


41 3-LOBE ROTOR CY5SnBIM VERSIONE ST 2 2005B011 2005B012 2005B013
41 2-LOBE ROTOR CY5SnBIM VERSIONE ST 2 2005B035 2005B036 2005B037
41 3-LOBE ROTOR CY5SnBIM VERSIONE SM 2 2005B023 2005B024 2005B025
41 2-LOBE ROTOR CY5SnBIM VERSIONE SM 2 2005B102 2005B048 2005B049

O.M.A.C. s.r.l.
Chap.7 - pag. 22 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS DESCRIPTION Q.TY B550 B660 B680

42 LOCKING NUT FOR STANDARD ROTOR 2 2004B105 2004B106


43 LOCKING NUT O-RING 2 404T3225 404T4350
44 FRONT COVER 1 2006B005 2006B006
45 COVER O-RING 1 404T003 404T61900
46 BACK STUD 4 419A14X53 419A14X85
8
47 FRONT STUD
12(*)
419A21X46 419A14X52

48 BACK PIN 2 417A14X30 417A10X55


49 FRONT PIN 2 417A14X30 417A10X30
50 ROTOR O-RING 2 404T3200 404T4312
8
51 CAP NUT
12(*)
414A12 414A14

52 CAP NUT 4 414A14 414A14


53 PLANE WASHER 4 412A14 412A14
54 PLANE WASHER 12 412A12 412A14
55 PLANE WASHER 6 412F12 412F16
73 INSPECTION COVER 1 2001L221 2001L222
74 SCREW 4 411A06X16 411A06X16
75 BEARING SUPPORT 2 2001G150 2001G151
76 SCREW 8 411A10X30 411A12X40
77 BACKBULL RING 2 2001F201 2001F202
78 SCREW 8 411A10X30 411A12X35
79 SEAL FLANGE 1 - 2006B132
80 STUD 8 - 419A14X75
81 PLANE WASHER 8 - 412A14
82 CAP NUT 8 - 414A14
83 FLANGED PORT 2 - 2006B152 2006B153
84 PORT O-RING 2 - 404T005 404T8850
85 SCREW 8 - 419A16X60
86 PLANE WASHER 8 - 412A16
87 CAP NUT 8 - 414A16
88 OIL CLOSE CAP 1 407L34T 407L1T
111 END COVER FOR HEATING VERSION 1 2006B055 2006B056
113 END COVER FOR JACKET 1 2006B168 2006B166
114 SCREW 4 411A08X25 411A08X25
115 END COVER JACKET 1 4004T8975 404T81400
302 SCREW 4 410A06X16 410A06X16
304 NAME PLATE 1 4034A100 4034A100
305 RIVET 4 44301027 44301027
306 EYEBOLT 2 432F12 432F16
B550 B660 B680

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 23
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.4.3 B550 B660 B680: Seals section drawings

Seals section drawing B550

UM Lip Seal S1 Lip Seal Packing gland

Packing Gland Single Mechanical Seal


with liquid barrier “U7K“ “KL2A“ “C5E“

Double HN Lip Seal Single Mechanical


“KL2A”, “U7K“, “C5E“ Flushed “KL2A”, “U7K“, “C5E“ Double Mechanical Seal
B550 B660 B680

O.M.A.C. s.r.l.
Chap.7 - pag. 24 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

Seals section drawing B660 B680

UM Lip Seal Packing gland

Packing Gland Single Mechanical Seal


with liquid barrier “U7K“, “KL2A“, “C5E“

Single Mechanical
Flushed “KL2A”, “U7K“, “C5E“ Double Mechanical Seal
B550 B660 B680

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 25
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS. DESCRIPTION Q.TY B550 B660 B680

200 SEAL STOP PIN 2 2014B200 - -


201 SINGLE MECHANICAL SEAL 2 see par. 7.1.4.6
210 BALANCING RING 2 see par. 7.1.4.5
218 SCREW 12 410A10X20 411A06X20S
220 FLUSHING SEAL BOX 2 2014B144 2014B164
221 O-RING 2 404T4437 404T4625
222 SCREW 12 411A10X40 -
223 SEAL RING UM 2 402V1109510 402U19016015
224 ROTATING RING 2 2004B166 2004B155
225 BUSH O-RING 6 404T4312 404T4475
226 GRANO DI FISSAGGIO ANELLO ROTANTE 6 420A08X06 420A08X12
227 SPINA 4 417A08X15 -
230 BALANCING RING U7K (SINGLE MECH. SEAL) 2 see par. 7.1.4.5
BALANCING RING U7K
231
(DOUBLE MECH. SEAL)
2 see par. 7.1.4.5

232 O-RING 2 404T4437 404T215


233 SCREW 6 - 410A14X30
234 BEARING BOX FOR DOUBLE SEALS 1 - -
235 FLUSHING BOX FOR DOUBLE SEAL 2 2014B160 2014B152
236 COVER 2 2014B162 2014B158
237 SCREW 4 410A10X20 410A10X20
238 O-RING 2 404T4437 404T4562
239 SEAL PROTECTION 2 4034A008 4034A006
240 UM LIP SEAL IN °VITON (F.K.M.) 4 402V857010 402V13011010
240 UM LIP SEAL IN E.P.D.M. 4 402U857010 402U13011010
240 S1 LIP SEAL 2 402Q857010 402Q13011010
240 DOUBLE HN LIP SEAL 4 - -
241 ROTATING BUSH FOR UM / S1 LIP SEAL 2 2004B159 2004B160
241 ROTATING BUSH FOR HN SEAL 2 - -
242 BUSH O-RING FOR UM / S1 LIP SEAL 2 404T168 404T4400
242 BUSH O-RING FOR HN LIP SEAL 2 - -
243 UM / S1 PIN 6 420A06X06 420A08X10
243 HN PIN 6 - -
244 UM SUPPORT 2 2014B054 2014B056
244 S1 SUPPORT 2 2014B064 -
244 HN SUPPORT 2 404T4437 -
245 UM O-RING SUPPORT 2 410A10X25 404T4625
245 HN O-RING SUPPORT 2 410A10X25 -
246 UM SUPPORTSCREW 6 - 410A14X20
246 S1 SUPPORT SCREW 6 - -
246 SCREW FOR HN LIP SEAL FLANGE 6 - -
247 PIN FOR HN LIP SEAL FLANGE 4 417A08X15 -
247 FOR UM LIP SEAL FLANGE 4 - -
B550 B660 B680

280 KIT PACKING GLAND IN P.T.F.E. 1 205P80968 205P11013412


281 STUFFING BOX SEAL SUPPORT 2 2004B164 2004B165
282 ROTATING BUSH O-RING 2 404T168 404T4400
283 SCREW 6 420A06X06 420A08X10
284 STUFFING BOX SEAL SUPPORT 2 2014B074 2014B076
285 FLANGE SUPPORT O-RING 2 404T4437 404T4625
286 SCREW 3 411A10X16 419A14X110
287 PIN 4 417A08X16 -
288 PACKING GLAND ADJUSTER 2 2014B104 2014B106
289 SCREW 2 410A10X25 413A14

O.M.A.C. s.r.l.
Chap.7 - pag. 26 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

POS. DESCRIPTION Q.TY B550 B660 B680

290 KIT PACKING GLAND IN P.T.F.E. WITH LIQUID BARRIER 1 201P80968 201P11013412
291 FLUSHED STUFFING BOX SEAL SUPPORT 2 2014B080 2014B082
292 HYDRAULIC RING 2 2014B124 2014B125
295 SPACER 2 2014B131 2014B132
296 MECHANICAL SEAL SUPPORT 2 - 2014B092
297 SUPPORT O-RING 2 - 404T4625
298 SCREW 4 - 410A14X20
299 PIN 2 430A08X18 430A08X18

7.1.4.4 B550 B660 B680: Gasket or ring codes for mechanical seals
MECHANICAL SEAL
RING TYPE RING MODEL B550 DIAMETER 65 B660 B680 DIAMETER 100
MATERIAL

U7K 404U6262
404U189
ROTATING KL2A 404U65X4.5

S.S. AISI 316 L C5E 404U168 -


CARBON U7K 404U6300 404U8450
STATIONARY KL2A 404U6450
404U76X4.65
C5E -
U7K 404U6262 -
ROTATING KL2A 404U65X4.5 404U189

TUNGSTEN CARBIDE C5E 404U168 -


CARBON U7K -
404U6300
STATIONARY KL2A 404U6450
C5E 404U76X4.65 -
U7K 404U6262
404U189
ROTATING KL2A 404U65X4.5

TUNGSTEN CARBIDE C5E 404U168 -


TUNGSTEN CARBIDE U7K 404U8450
404U6300
STATIONARY KL2A 404U6450
C5E 404U76X4.65 -
KL2A - -
ROTATING
CERAMIC C5E 404U168 -
CARBON KL2A - -
STATIONARY
C5E 404U76X4.65 -

SILICON CARBIDE ROTATING 404U65X4.5 404U189


KL2A
CARBON STATIONARY 404U76X4.65 404U6450

CERAMIC ROTATING 404U168 -


C5E
RULON STATIONARY 404U76X4.65 -

SILICON CARBIDE ROTATING 404U65X4.5 404U189


KL2A
SILICON CARBIDE STATIONARY 404U76X4.65 404U6450

SILICON CARBIDE ROTATING 404U65X4.5 404U189


KL2A
TUNGSTEN CARBIDE STATIONARY 404U6300 404U6450
B550 B660 B680

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag. 27
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.4.5 B550 B660 B680: Balancing ring codes for single and flushed mechanical seals

B550 B660 B680


MECHANICAL SEAL MATERIAL STATIONARY RING
MATERIAL CODE RING MODEL SINGLE FLUSHED SINGLE FLUSHED
SEAL SEAL SEAL SEAL

CARBON U7K 2014B004 2014B010 2014B006 2014B006


S.S. AISI 316 L
CARBON
3 S.S.AISI316L KL2A 2014011 2014B011
2014B224 2014B234
S.S. AISI316L C5E - -
CARBON U7K - -
TUNGSTEN CARB. 2014B004 2014B010
CARBON
4 TUNGSTENCARBIDE KL2A 2014B006 2014B006
TUNGSTENCARBIDE C5E 2014B218 2014B244 - -
TUNGSTENCARBIDE U7K
TUNGSTEN CARB. 2014B004 2014B010 2014B021 2014B021
TUNGSTEN CARB.
5 TUNGSTENCARBIDE KL2A

TUNGSTENCARBIDE C5E 2014B218 2014B244 - -

CERAMIC KL2A - - - -
CARBON
6 CERAMIC
C5E 2014B224 2014B234 - -
SILICON CARBIDE
CARBON
A SILICONCARBIDE KL2A 2014B224 2014B234 2014B011 2014B011
CERAMIC
RULON
7 CERAMIC C5E 2014B224 2014B234 - -
SILICON CARBIDE
SILICON CARBIDE
8 SILICONCARBIDE KL2A 2014B224 2014B234 2014B011 2014B011
SILICON CARBIDE
TUNGSTEN CARB.
9 TUNGSTENCARBIDE KL2A 2014B004 2014B010 2014B011 2014B011

7.1.4.6 B550 B660 B680: Single and double mechanical seals codes

COD. SEAL MATERIAL SEAL MODEL B550 B660 B680

U7K 4U065U7KXZ7 -
S.S. AISI 316 L / CARBON
O-RING IN EPDM
KL2A 4U065KL2AXZY 4U100KL2AXZY
C5E 4U065C5EBGE -
U7K 4U065U7KXZY -
3 S.S. AISI 316 L / CARBON
KL2A 4U065KL2AZYV 4U100KL2AZYV
Q3 O-RING IN °VITON
C5E 4U065C5EBGV -
U7K 4U065U7KXZP -
S.S. AISI 316 L / CARBON
O-RING IN P.T.F.E.
KL2A 4U065KL2AZYP 4U100KL2AZYP
C5E 4U065C5EBGP -
U7K 4U065U7K3Z7 -
TUNGSTEN CARBIDE / CARBON
O-RING IN E.P.D.M.
KL2A 4U065KL2AKZE 4U100KL2AKZE
C5E 4U065C5EBUE -
U7K 4U065U7K3ZY -
TUNGSTEN CARBIDE / CARBON
4 O-RING IN °VITON
KL2A 4U065KL2AKZV 4U100KL2AKZV
C5E 4U065C5EBUV -
U7K 4U065U7K3ZP -
TUNGSTEN CARBIDE / CARBON
O-RING IN P.T.F.E.
KL2A 4U065KL2AKZP 4U100KL2AKZP
C5E 4U065C5EBUP -
B550 B660 B680

U7K 4U065U7K337 4U100U7K337


TUNGSTEN CARBIDE / TUNGSTEN CARBIDE
O-RING IN E.P.D.M.
KL2A 4U065KL2AKKE 4U100KL2AKKE
C5E 4U065C5EUUE -
U7K 4U065U7K33Y 4U100U7K33Y
5 TUNGSTEN CARBIDE / TUNGSTEN CARBIDE
KL2A 4U065KL2AKKV 4U100KL2AKKV
Q5 O-RING IN °VITON
C5E 4U065C5EUUV -
U7K 4U065U7K33P -
TUNGSTEN CARBIDE / TUNGSTEN CARBIDE
O-RING IN P.T.F.E.
KL2A 4U065KL2AKKP 4U100KL2AKKP
C5E 4U065C5EUUP -

O.M.A.C. s.r.l.
Chap.7 - pag. 28 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

COD. SEAL MATERIAL SEAL MODEL B550 B660 B680

CERAMIC / CARBON KL2A - -


O-RING IN E.P.D.M. C5E 4U065C5EBVE -

CERAMIC / CARBON KL2A - -


O-RING IN °VITON C5E 4U065C5EBVV -

CERAMIC / CARBON KL2A - -


6 O-RING IN P.T.F.E. C5E 4U065C5EBVP -
SILICON CARBIDE / CARBON
O-RING IN E.P.D.M.
KL2A 4U065KL2AZUE 4U100KL2AZUE

SILICON CARBIDE / CARBON


O-RING IN °VITON
KL2A 4U065KL2AZUV 4U100KL2AZUV

SILICON CARBIDE / CARBON


O-RING IN P.T.F.E.
KL2A 4U065KL2AZUP 4U100KL2AZUP

CERAMIC / RULON
O-RING IN E.P.D.M.
C5E 4U065C5EYVE -

CERAMIC / RULON
7 O-RING IN °VITON
C5E 4U065C5EYVV -

CERAMIC / RULON
O-RING IN P.T.F.E.
C5E 4U065C5EYVP -

SILICON CARBIDE / SILICON CARBIDE


O-RING IN E.P.D.M.
KL2A 4U065KL2AUUE 4U100KL2AUUE

SILICON CARBIDE / SILICON CARBIDE


8 O-RING IN °VITON
KL2A 4U065KL2AUUV 4U100KL2AUUV

SILICON CARBIDE / SILICON CARBIDE


O-RING IN P.T.F.E.
KL2A 4U065KL2AUUP 4U100KL2AUUP

SILICON CARBIDE / TUNGSTEN CARBIDE


O-RING IN E.P.D.M.
KL2A 4U065KL2AUKE 4U100KL2AUKE
SILICON CARBIDE / TUNGSTEN CARBIDE
9 O-RING IN °VITON
KL2A 4U065KL2AUKV 4U100KL2AUKV
SILICON CARBIDE / TUNGSTEN CARBIDE
O-RING IN P.T.F.E.
KL2A 4U065KL2AUKP 4U100KL2AUKP

7.1.5 Name and codes of pumping bodies


This naming refers to position n. 40 (pumping body) of the construction exploded view drawings in sections 7.1.1.1, 7.1.2.1, 7.1.3.1, 7.1.4.1 and identifies
the item code to order as a spare part.
2 3 1 0 2 B 0 7
Example: code 23102B07
A B C D E F G G
Code 23102B07 identifies the finished body, with heated chamber, for mechanical seals, for DIN11851 openings, made of AISI 316 L material, for the
size of the LDPU.

The code of the pump bodies is made up as follows:


A B C D E F G G

A CODIFY 2 = FINISHED PART 5 = SEMIFINISHED PART 6 = CAST PART

B FAMIGLIA 3 = FAMILY MEMBERSHIP

C VERSION 0 = STANDARD 1 = HEATED PUMP BODY 2 = ASEPTIC 3 = HEATED ASEPTIC


7 = ENLARGED
5 = HIGH PRESSURE + 6 = ENLARGED
4 = HIGH PRESSURE INLET PORT +
HEATED PUMP BODY INLET PORT
HEATED PUMP BODY

HOUSING TYPE
D 0 = MECHANICAL AND LIP SEAL 1 = PACKING GLAND SEAL 9 = SPECIAL
SEALS

1 = FLANGE PN 16
E CONNECTIONS 0 = THREAD GAS-BSP 2 = DIN11851 3 = SMS 4 = RJT
UNI2278
5 = IDF-ISS 6 = TRI-CLAMP 7 = GAS 8 = ENOLOGIC 9 = SPECIAL

F MATERIAL B H I J R

G-G Numerical order in relation to the size

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag.29
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

7.1.6 Codes of the springs used in the mechanical safety valve


The table below list the identification codes of the springs used in the mechanical safety valves (see ref. section 3.3.3), codes that can be used to order
any spare parts.

PUMP SPRING CODE

B100 (0 ÷ 5 bar) code 422F015 (6 ÷ 10 bar) code 422F016 -

B105 B110 B115 (0 ÷ 13 bar) code 422F001 (14 ÷ 17 bar) code 422F011 (18 ÷ 20 bar) code 422F002

B215 B220 (0 ÷ 13 bar) code 422F001 (14 ÷ 17 bar) code 422F011 (18 ÷ 20 bar) code 422F002

B325 B330 B390 (0 ÷ 7 bar) code 422F003 (8 ÷ 13 bar) code 422F011 (14 ÷ 17 bar) code 422F005

B430 B440 (0 ÷ 7 bar) code 422F017 (8 ÷ 11 bar) code 422F004 (12 ÷ 17 bar) code 422F008

B470 B490 (0 ÷ 7 bar) code 422F013 (8 ÷ 15 bar) code 422F014 -

7.1.7 Codes of the springs used in the external bridge mechanical safety valve
The table below lists the kinds of springs used in the external bridge mechanical safety valves (see ref. section 3.3.3): depending on the adjustment
pressure and valve diameter one can recognise the spring identification letter: “A”, “B”, “C”, “D”, “E”.

PRESSURE (BAR)
VALVE DIMENSION
SPRING “A” SPRING “B” SPRING “C” SPRING “D” SPRING “E”

DN 25 0.5 ÷ 2 bar 1 ÷ 3.5 bar 1 ÷ 6.5 bar 1 ÷ 9 bar 1 ÷ 10 bar

DN 32 0.5 ÷ 2 bar 1 ÷ 3.5 bar 1 ÷ 6.5 bar 1 ÷ 9 bar 1 ÷ 10 bar

DN 40 0.5 ÷ 2 bar 1 ÷ 3.5 bar 1 ÷ 6.5 bar 1 ÷ 9 bar 1 ÷ 10 bar

DN 50 0.5 ÷ 2 bar 1 ÷ 3.7 bar 1 ÷ 6 bar 1 ÷ 10 bar

DN 65 0.5 ÷ 2 bar 0.5 ÷ 3.3 bar 1 ÷ 7.7 bar

DN 80 0.5 ÷ 1.7 bar 0.5 ÷ 2.3 bar 1 ÷ 5 bar

DN 100 0.5 ÷ 1.3 bar 0.5 ÷ 4 bar

7.2 Recommended spare parts


It is advisable for the Customer, in order to ensure the shortest plant down time, to stock up on spare parts relating to sealing parts complete with
gaskets.
The codes relating to these components can be found in sections 7.1.1.3 - 7.1.1.4 - 7.1.2.3 - 7.1.2.4 - 7.1.2.6 - 7.1.3.3 - 7.1.3.4 - 7.1.3.6 - 7.1.4.3 - 7.1.4.4
- 7.1.4.6, depending on the size of the B Series lobe displacement pump, part of the LDPU.

7.3 How to order spare parts


With reference to the previous sections, the single parts that compose the LDPU are marked with an internal O.M.A.C. code.
This code is of vital importance when communicating with our spare parts department.
In order to have the spare parts delivered quickly you must communicate the following data to us, even via a purchase order:
• machine model (*)
• serial number (*)
• component description
• component reference code (refer to the attachments of the manual)
• desired amount.
(*) information that can be found on the machine, on the nameplate

Contacts:
• Tel.: 0522/629371 or 0522/629923 and ask for the “spare parts” department
• Fax: 0522/628980
• E-mail: [email protected]

O.M.A.C. s.r.l.
Chap.7 - pag. 30 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

NOTES
________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

_____________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

_______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.7 - pag.31
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

NOTES
________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

____________________________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________________________________________

___________________________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

O.M.A.C. s.r.l.
Chap.7 - pag. 32 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

CHAPTER 8: ASSISTANCE
O.M.A.C. S.r.l. has a customer after-sales assistance service that can solve any problem in relation to the LDPU.
In the case there are anomalies in the lobe pumps used, contact our after-sales assistance service which will see to solve the problem.

Contacts:
• Tel.: 0522/629371 or 0522/629923 and ask for the “assistance” department
• Fax: 0522/628980
• E-mail: [email protected]
Only O.M.A.C. S.r.l. technical personnel is qualified to carry out extraordinary maintenance activities that the LDPU requires.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Chap.8 - pag. 1
Rev.4 del 01/2010 O.M.A.C. s.r.l.

O.M.A.C. s.r.l.
Chap.8 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

CHAPTER 9: WARRANTY

O.M.A.C. S.r.l. grants a warranty for twenty-four to months from the date of delivery for new LDPUs that have been subjected to normal work of eight
hours a day, while if they will be subjected to a double or triple work shift, during the day, the warranty term will be respectively reduced by half (in the
case of a double work shift) or by a third (in the case of a triple work shift).

Unless otherwise agreed, the warranty is only for new LDPUs manufactured by the seller and used as described in the attached technical sheet, thus
excluding LDPUs used in unintended manners, overhauled LDPUs and those parts of LDPUs built by other companies for which the warranties of the
respective manufacturers apply (electrical panel, bridge By-Pass, etc.).

The warranty consists in repairing or replacing all pieces that are possibly defective in terms of materials or processing, returned free port to the hea-
dquarters of OMAC s.r.l.

The warranty does not extend to failures resulting from improper installation, inexperience in the running the LDPU, from poor maintenance, negligence,
when changes have been made to the LDPU or non-original spare parts have been used, without the written consent of OMAC s.r.l. .

Electrical components are always excluded from the warranty.

Under no circumstances can the manufacturer be charged for damages due to non-compliance with our requirements, or manipulations carried out by
untrained personnel. Under no circumstances can we replace for free those pieces whose failure or breakage depends on normal wear and tear, misuse,
or in inappropriate use conditions or use of the LDPU other than what was agreed in the sale contract.

Any assistance required during the warranty period must be carried out solely by OMAC s.r.l. skilled technicians. In the case this LDPU is used for abra-
sive/corrosive products, this warranty is reduced to 2 months.

If the LDPU is tampered with by unauthorised personnel the warranty is voided.

All repairs or replacements of pieces for failures not attributable to manufacture defects or poor quality of the material will be charged in full to the Cu-
stomer.

AVVERTENZA:

An installation other than that indicated in chapter, a use other than that indicated in chapter 4, the possible seizure of rotors, caused by foreign bodies,
such as pipe process scraps, welding cinders, dust, etc. will void the warranty.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 Chap.9 - pag. 1
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2010 O.M.A.C. s.r.l.

O.M.A.C. s.r.l.
Chap.9 - pag. 2 Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980
E-mail:[email protected] SitoWeb:www.omacpompe.com
Rev.4 del 01/2011 O.M.A.C. s.r.l.

O.M.A.C. s.r.l.
Via Giovanni Falcone, 8 42048 Rubiera (RE) - Italy Tel.0522/629371 - 629923 Fax 0522/628980 XIII
E-mail:[email protected] SitoWeb:www.omacpompe.com
Organismo accreditato da ACCREDIA
Body accredited by ACCREDIA

O.M.A.C. S.R.L.
Via G. Falcone nr. 8 – 42048 RUBIERA (RE) – ITALY (UE)
Tel. 0522/629371 – 629923 / Fax. 0522/628980
9001:2008
WebSite: www.omacpompe.com E-mail: [email protected]

You might also like