Clevis Type61 Hot
Clevis Type61 Hot
Clevis Type61 Hot
Temperature
CALCULATION IS BASED ON VGB-R 510 L RULES Type 75
250 °C 275 °C 300 °C
Material Max. permissible loads ( static ) - normal load S
Load group Clevis with pin type 61 Thread
Clevis (part1) pin (part2) kN kN kN mm
D 61 D9 19 / 61 D9 59 M 10 P250GH C35E+QT 2.2 2.2 2.2 6
(1), 2 61 29 12 / 61 29 52 M 12 P250GH C35E+QT 6 5.8 5.3 8
3 61 39 12 / 61 39 52 M 16 P250GH C35E+QT 10.1 10.1 9.3 10
4 61 49 12 / 61 49 52 M 20 P250GH C35E+QT 15.9 15.1 14.4 12
5 61 59 12 / 61 59 52 M 24 P250GH C35E+QT 24.4 23.1 22 15
6 61 69 12 / 61 69 52 M 30 P250GH C35E+QT 50 47 45 20
7 61 79 12 / 61 79 52 M 36 P250GH C35E+QT 74 74 70 25
8 61 89 12 / 61 89 52 M 42 P250GH C35E+QT 101 95 91 30
9 61 99 12 / 61 99 52 M 48 P250GH C35E+QT 116 109 104 30
10 61 10 12 / 61 10 52 M 56 x 4 S355J2G3 C35E+QT 177 168 160 40
20 61 20 12 / 61 20 52 M 64 x 4 S355J2G3 C35E+QT 226 216 207 45
30 61 30 12 / 61 30 52 M 68 x 4 S355J2G3 C35E+QT 226 216 207 45
40 61 40 12 / 61 40 52 M 72 x 4 S355J2G3 S355J2G3 340 320 300 50
50 61 50 12 / 61 50 52 M 80 x 4 S355J2G3 S355J2G3 420 390 380 60