0% found this document useful (1 vote)
443 views49 pages

2 - Functions and Features of PCBs

The document discusses 1) the classification and functions of printed circuit boards (PCBs) and 2) PCB application standards. It classifies PCBs by name, location, function, speed, and segment. It also provides examples of specific PCB types like DOC-100 and their diagrams, functions, and application standards at different speeds.

Uploaded by

Quang Pham Duy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
443 views49 pages

2 - Functions and Features of PCBs

The document discusses 1) the classification and functions of printed circuit boards (PCBs) and 2) PCB application standards. It classifies PCBs by name, location, function, speed, and segment. It also provides examples of specific PCB types like DOC-100 and their diagrams, functions, and application standards at different speeds.

Uploaded by

Quang Pham Duy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 49

1.

3 PCB functions and features


1) PCB classification

① Classification by name


A B
나 C
다 D
라 마
E F

Working Segment

Type Location Function Speed Seg. Wor.seg. When works are segmented
within a PCB, mark with

0~9.

PCB segment

When the PCBs of the same

function has various

PCB speed segment forms and are not cla-

1 : 60 ~ 105m/min ssified in A,B,C and

2 : 120 ~ 150m/min D, mark with 0~9,

3 : 180 ~ 240m/min A, B… sequentially.

When the PCB is used commonly

regardless of speed, PCB function segment

use the type name develo- C : Control

ped and applied first. P : Power (Power supply)

A : Annunciator

S : Monitoring panel

L : LON

PCB location seg. R : I/O(Input/Output)

P : Power electronics D : Door

O : Operation G : G/A (Gate Array)

H : Hall I : Indicater

C : Car V :Voice(Voice synthesizer)

D : Door F : Flickering

D:Distributed control S : Monitoring panel M : Dot Matrices

- 14 -
② PCB application standard
Speed
Segment Di1(60~105 m/min) Di2 ~Di5
Usage
Main CPU PCB for operations DOC - 100 DOC - 200

Control DSP PCB speed control DPC - 100 DPC-100 (Di2)

board DPC-300 (Di3~Di5)

GDC PCB DPP - 10X DPP-200 (Di2)

DPP-300 (Di3~Di5)

Power rectifying section DOP - 100

ANN PCB DOA - 100 DOA - 100

I/O PCB DOR-200 (120,150 m/min)

DOR-210 (Standard relay)

DOR-220(for PDL)

DC Link end Voltage detecting DPP-310

DM TYPE relay PCB DOD-200

LON relay PCB DOL-210

PCB supplied monitoring DOS-100 DOS-100


panel for local

Car Car LON PCB DCL-200 DCL-200(32 FLs), DCL-210(64 FLs)

CPI PCB DCI-200~270(8 type) DCI-200~270(8 types)

Hall button for hall chime DHG - 130 DHL-230

Hall 1 column paral. button(all Fs)

Standard hall button DHG - 140 DHL-240

Vertical IND PCB DHI - 100 DHI-200

Horizontal IND PCB DHI - 110 DHI-210

Vertical DML PCB DHM - 100,110 DHM-100,110

Horizontal DML PCB DHM - 120,130 DMH-120,130

Hall lantern DHF - 100 DHF-100

Door INV. DOOR PCB DCD - 201,202 DCD-201,202

- 15 -
2) DOC-100 PCB
① Diagram DOC-100 PCB
JP1

ANN
+5V

WE
EEPROM : Write Enable
: Writable ANNUNCIATOR
SD

: Unwritable CON'g CONNECTOR

BAT1 LED Indication Function


Main CPU Reset
○ Normal Det'd in rever.

DIR-E IALM SYS1 SYS2 PF


DIR_E
● Detected direc.
ST

EXT1
Red
(BAT) RESET ○ Normal ALARM sig.
IALM
RAM ● Detected detected Red
DATA Run CPU
BACK UP SYS1 ⊙ Normal Grn
Extention PCB inserting WDT
SPD CPU
SYS2 ⊙ Normal Grn
Seg. CONNECTOR fun. WDT
AB

○ Normal Power
SD DEBUG PF Red
ST Voice synthesizer ● Detected FAIL det'd
EXT2

LON com.

LON
AB OUTPUT(firefighting, aircon...) LON ⊙ Normal Grn
1 chk
HA SWs in hall pit
AA INPUT(firefighting, aircon...)
CA CAR DOOR(OPB SW,SES..) SPEC1 TRM3 : For CAR com. TML proce.

SPEC2
CAR safety SW(1,2 firefighting...)

DIP SW
CB
DIP SW TRM3 (inserted in TML only)
AC

AD R/E power,ΦA,ΦB-phase detecting


SM CRT communication
1 SH HALL communication LONRES
SC CAR communication
TB1 PCB power(5V, 15V, GND) TMR1 LON Chip Reset
HA

TMR2 LON Chip ID setting


BUZ

For detect'g DR ZONE when MB nud. open


SW & buzzer(NORMAL) SERV
1 R/E direction setting
:TR-M/C right arrang.(right)
NORMAL UP :TR-M/C reverse arra.(left) Connected to VA
CB

RESCUE

S2 connector of DPC-10X PCB


DIR
RIGHT
LEFT

1 ABNORMAL DN
AUTO
MAINT

LED Indication Function LED


RDZ

S1
○ OFF ● ON DSP
CA

⊙ In com. HALL
IDLE1 ⊙ Flicker
MAINT ● Standby com.
NORMAL NORMAL ○ Standby HALL LED Indication & func.
TX1
R2LD

1 DMC ⊙ In com. com. ○ LON Chip normal


R/S
⊙ In com. CRT com. SER LON Chip
D.M.C IDLE2 ●
STOP CHECK (CAR H/W,S/W Error
2R24786
DOC-100
● Standby
AA

SW S W function ○ Standby CRT com. com.) LON Chip


TX2 ⊙
R5SC

S1 AUTO/MAINT run ⊙ In com. CHECK Confing Error


1
S2 AUTO Up/Dn run TRM1.2 : For G/A com. TML proce.
DMC Door Machine Cut TRM2 TRM1
R/S
(Inserted in TML only)
Run/Stop
TX2 TX1 SER GND
5V 5V 15V GND GND FG Grn Grn
3 3 3 Re
Grn Grn 1
1 1 1
FG TB1 AD SM IDLE2 IDLE1 SH SC

⑴ Details

① DIR-E (red): Indicates rotary encoder direction setting. If there is any error

in the setting, LED will light up. If normal, LED will remain off.

② IALM (red) : Indicates alarms. If there is one error among the following 5

conditions, relative LED will light up.

- 16 -
No. Conditions Error detection method
1 Safety relay error R5SC Relay remains OFF
2 DOC-100 Watchdog error SYS1 LED remains ON or OFF

3 DPC-100 Watchdog error SYS2 LED remains ON or OFF


4 P48V error PF LED remains ON (Lights up)

5 LON communication error SER LED remains ON

③ SYS1 :Flickers when DOC-100 Watchdog is normal. If abnormal, remains ON or OFF.


④ SYS2 :Flickers when DPC-100 Watchdog is normal. If abnormal, remains ON or OFF.
⑤ PF : Remains OFF when P48 is normal. If abnormal, remains ON.
⑥ LON : LED for checking LON communication. If the communication with CAR LON is
normal, it will flicker. If abnormal, remains ON or OFF.
⑦ TX1 : G/A Com checking LED. Flickers during communication and remains OFF other times.
⑧ IDLE1: G/A Com checking LED. Flickers during communication and remains ON other times.
⑨ TX2 : G/A Com checking LED. Flickers during communication and remains OFF other times.
⑩ IDLE2: G/A Com checking LED. Flickers during communication and remains ON other times.
⑪ SER : Remains OFF when LON CPU LED is normal. If abnormal, remains ON or flickers.
※ Caution
Green LED will flicker and red remains OFF in normal conditions.
Yet, IDLE1 & 2 LED and TX1 & 2 LED flickers in a shorter interial than other green LED.
⑵ Function table of switches, jumpers and dip switch(located in PCB)
Refer to ①~18 for details.
No. Name Switches Function Usually
1 JP1 Jumper pin or slide switch WE : E2PROM writing
2 RESET Tact Run CPU Reset
3 LONRES Tact LON CPU Reset
4 SER Tact ID setting
5 SPEC2 DIP SW Spec. setting 2
6 SPEC1 DIP SW Spec. setting 1
7 TMR1 HEX SW Light timer of car
8 TMR2 HEX SW Brake opening timer
9 RESCUE Toggle(Non-return,6pole) Dectects door zone in emergency Normal
10 S2 Toggle(Returnable,3pole) UP/DN in Maint. Operation
11 S1 Toggle(Non-return,3pole) Selects Auto/Maint. operation Auto
12 DMC Toggle(Non-return,3pole) Selects Door Machine Cut Normal
13 R/S Toggle(Non-return,3pole) Selects Normal/Stop Normal
14 DIR Jumper Pin Selects rotary encoder direction
15 TRM2 Jumper Pin Terminal R setting 2 G/A
16 TRM1 Jumper Pin Terminal R setting 1 G/A
17 TRM3 Jumper Pin Terminal R setting 3 LON
18 MAINT Jumper Pin Door open out of DR zone in maint.OPR.

- 17 -
① JP1 : WE position → EEPROM writable : when spec.is changed into DOA-100 at the side
+5V position → EEPROM unwritable : normal

+5V SLIDE SW
WE

JP1

※ After spec. modification, JP1 shall be positioned on +5V to prevent


the spec. data from deletion.
② Reset : Run CPU ,Speed CPU, LON CPU Reset
③ LONRES : LON CPU Reset

④ SER : LON CHIP ID setting


※ LON BUILDER(Equipment used for R&D)is used for communication data analysis.
⑤ SPEC setting 2 : SPEC2
BIT Setting during ON Setting during OFF
BIT 1 Unused Unused ※ While Bit 8 is ON, errors that
BIT 2 " " persist which can not be
BIT 3 Hall B/T jam func. Delet Hall B/T jam func. normally initialized can be
BIT 4 Unused Unused deleted.
BIT 5 " "
BIT 6 " " ※ Be sure to set OFF after
BIT 7 " " the error is deleted.
BIT 8 " "

⑥ SPEC setting 1 : SPEC1


BIT Setting during ON Setting during OFF
BIT 1 With duplex operation Without duplex operation
BIT 2 Lift # 2 Lift # 1
BIT 3 Lift # 2 row duplex operation hall net Lift # 1 rows duplex operation hall net
BIT 4 Load detector - Differential trans. Load detector - MICRO S/W
BIT 5 Setting to verification mode Normal
BIT 6 With voice synthesizer Without voice synthesizer
BIT 7 With emergency and control setting Without emergency and CTRL setting
BIT 8 In-factory checking mode Normal

※ Car 1 and 2 of Bit 2 can be set only when Bit 1 is ON.


checking mode of Bit 5 is ON, checking points can be registered
through CRT monitoring system.

⑦ In-car light timer setting(TMR1) (Unit : min)


BIT 0 1 2 3 4 5 - 18
6 - 7 8 9 A B C D E F

Seg. 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
※ Factory set value is BIT 2 (4 min).
TMR1, ※ In-car light timer setting, is to set the time SPAN for in-car light to turn
OFF when there is no hall call or car call.
※ Setting Bit value to 0 means, light will be turned ON/OFF by switch.(Remains ON status)
※ Hexa switch is fragile, be sure to use cross-shaped driver of a
proper size.

⑧ Brake opening timer adjustment(TMR2) (Unit : ms)


BIT 0 1 2 3 4 5 6 7 8 9 A B C D E F
Seg. -240 -210 -180 -150 -120 -90 -60 -30 Sta. 30 60 90 120 150 180 210

Decrease Stand. Increase

※ Function : When a starting shock occurs after mechanical adjustment of brake,


adjust brake opening time.

※ Standard is set to Bit 8 in factory. It increases or decreases by 30ms per Bit.


※ If a starting shock occurs during "No Load Up" and "No Load Down" due to brake

opening during installation adjustments, decrease the BIT.

※ If there is a sliding during "No Load UP" or slippage to CWT side during "No Load
Down" due to brake opeing being too early, increase the BIT.

⑨ Rescue : Door Zone checking in a rescue by handle.

-. Normal position : NORMAL


-. Position during handle operation : ABNORMAL

LDC-proce.sect.

Emergency light
lamp battery

(Fig.1) Rescue Switch Connection

※ If 1-2 and 4-5 are connected by setting the switch to "Normal" in a normal

condition as shown in the Fig.1, 48V power is input through LDC and processed in LDC
- 19 -
process section.If a rescue operation is required in case of power failure
or other errors, set the switch to "Abnormal". Then, the buzzer operated by battery power

will sound beyond door opening zone and will not sound in a door opening zone.

This function is very convenient for a manual rescue.

※ Buzzer will not sound without R5SC relay inserted, be sure to insert R5SC relay.

※ Be sure to set main MCCB to OFF in a manual rescue operation.

※ Verify that the buzzer sounds beyond door opening zone with

this switch in Abnormal position during connection check.

※ Be sure to set the switch in Normal position after operation checking.

⑩ S2 : UP/DOWN Switch, returnable Toggle Switch during maint. run.

※ Operates only while the switch is kept pressed upward or downward.

⑪ S1 : Auto/Machine room slow operation selection

-. Normal : AUTO

-. Machine room slow operation : MAINT

Input end
proce. sect.

Safety
chk cir.

MSK SW Input

(Fig.2) Auto/Maint, UP/DN Switch connection

※ As shown in the Fig. 2, 2-3 of S1 are connected normally and 1-2 are connected
in maintenance run.In machine-room-low-speed run mode, 1-2 connection of
- 20
S2(UP/DN) gets E/L to move up and-2-3 connection to move down.
⑫ DMC : Door Machine Cut

-. At normal : NORMAL

-. No power supply to door : D.M.C

External safety
chk cir.

(Fig. 3) DMC Switch connection

※ AS shown in the Fig. 3, if DMC Switch is set to 2-3, 48V power supply to
door machine is disconnected, and then, all input / output signals to door are

cut. Thus, close and open command of control panel does not register.

⑬ R/S : Safety related signal cut

-. Normal : NORMAL

-. Abnormal : STOP

DOOR M/C
48V Power

(Fig. 4) Normal/Stop switch connection

※ Cut 48V power supply for all safety related signals as shown in Fig. 4.

⑭ DIR : Decision of the direction of rotary encoder.


-. Right arrangement : RIGHT
-. Reverse arrangement: LEFT - 21 -
LEFT SHORT PIN
RIGHT
RIGHT

DIR

※ Without a jamp pin inserted, right is considened as the direction.

⑮ TRM2 : Terminal resistance setting of CRT monitoring net.

Car 1 Car 2
TRM2 TRM2
Remove short pin Insert short pin

CRT
monitoring
panel

(Fig. 5) CRT monitoring panel network in duplex operation

※ In case of duplex operation, insert short pin into only the side to which CRT

monitoring panel is not connected directly.(Farther side from CRT monitoring board)

※ In case of single unit, insert short pin.

16 TRM1 : Sets the terminal resistance of hall net

Unit 1 Unit 2
Remove short pin TRM1 TRM1 Remove short pin

HALL HALL
NET NET

(Fig. 6) Hall network in 2 line duplex operation

※ Remove all short pins from both unit 1 and 2, in the hall network in 2 line

duplex operation, as shown in Fig. 6.

※ In case of 1 line dulex operation network, insert short pin into the

farther unit from hall net as shown in Fig. 7.

- 22 -
Unit 1 Unit 2
Remove short pin TRM1 TRM1 Insert short pin
Remove short pin TRM1 TRM1

HALL
NET

(Fig. 7) Hall network in 1 line duplex operation


※ Insert short pin in case of single unit.
17 TRM3 : LON communication(Car side) terminal jumper

※ Verify that it is inserted.


18 MAINT : In order to open door beyond the door opening zone, you shall

a) Set the AUTO/MAINT switch of DOC-100 PCB in control panel to MAINT.


b) Insert a MAINT jumper.
Caution: Be sure to remove MAINT jumper short pin after installation at (high-
speed operation).
※ Function of each connector in DOC-100 PCB
Connector Number of Pin Function

CA 18 PIN Car input signal and door input/output signal

CB 8 PIN Car side switch input

AA 8 PIN Input in control panel

AC 8 PIN Output in control panel (Relay drive)

AB 18 PIN Input and output(Relay drive) in control panel

HA 10 PIN Hoist way limit switch input

TB1 TERMINAL BLOCK DC power supply in DOC-100 PCB

SD 9 PIN RS-232 Serial Port(for R&D)

ST 9 PIN RS-232 Serial Port(for voice synthesizer)

AD 4 PIN Rotary encoder power supply and signal

SH 4 PIN Hall board G/A communication

SM 4 PIN Monitoring panel & GEMIS G/A communication

SC 2 PIN Car LON communication

(4) Program element (Board)


Program element is likely to be removed or changed by light or static electricity
as it is written electrically. Much care should be taken in handling.
- 23
Program element is attached by DOC-XY - sticker. X represents horizontal
TYPE
coordinate(1∼15) and Y vertical coordinate(A∼M) as shown in Fig. 8.

Location in B/D

Fig. 8. Program element in DOC-100 B/D

Name Loc. Coor. Element used Function

U9(EVEN) ① 13A **27C010 Contains driving CPU O/S and driving program

U10(ODD) ② 12A 27C010 Contains driving CPU O/S and driving program

U16 ③ 7A 28C64 Sets spec.

U54 ④ 5C GAL16V8 For LON chip decoder

U41 ⑤ 1C GAL16V8 Checks error and rings alarm

U51 ⑥ 5D 27C256 LON CPU O/S and program

U44 ⑦ 11i GAL22V10 Drives speed CPU and output side

U35 ⑧ 6i EPM7032 Processes R/E input signal

** Two type of ROMs are available

There are two more elements using a socket(U1, U53) in DOC-100 B/D besides
the above program elements. U1 is run CPU(80C186) and U53(IDT71321) is
DPRAM for communication with LON chip. Thus,
- 24 - these two are not program elements.
* Removed or changed program element detection.
Name Function Detection Method

U9(EVEN) Operates run CPU SYS1 LED does not turn ON and OFF flicka.

U10(ODD) Operates run CPU SYS1 LED does not turn ON and OFF flicka.

U16 Sets spec. Floor information is garbled.

U54 LON Decoder SER LED turns ON.

U41 Rings alarm SYS1 LED becomes ON/OFF, No OUTPWTS.

U51 Operates LON CPU LON CPU O/S and LON program

U44 OUTPUT DRV Each relay and contactor doesn't operate.

U35 Processes R/E siganl Floor height isn't recognized.

⑷ Checking point at failure


① When SYSI LED doesn't flicker

-. Verify that +5V voltage is within +4.65V~+5V.

-. Verify that ROM(27C010) is properly inserted.

(Verify that even side and odd side are not switched.)

② When no letter appears on LCD(Liquid Crystal Display) of DOA-100 PCB

-. Verify that ANN connector is properly connected.

-. Make LCD brighter by turning the variable resistance(VR1) of DOA-100 PCB.

③ When floor information can not be written

-. Verify that the jumper of coordinate 10B is set to WE position.

(Writing is possible only with WE position)

④ When SER LED lights up

-. Verify that ROM(27C256) for LON is properly inserted at coordinate 5D.

-. Replace GAL(DOC-5C nameplate, IC name) of coordinate DOC-5C.

- 25 -
3) DOA-100 PCB
⑴ Description of DOA-100 PCB
※ DOA-100 PCB is composed of LCD and Key pad and connected by DOC-100 PCB
and 16P twist flat cable.
※ LCD displays the current state of control panel and can be inputted various commands,
address, data, etc. through key pad.
※ As DOA-100 PCB has a timer, the back light turns OFF automatically without any
key pad input for about 7 minutes. Press any one of "E", "A", "6" and "2" key on
the pad to turn ON the back light again.
※ As LCD is sensitive to temperature, clearness of letters in LCD may
vary according to temperature. The clearness can be adjusted by turning
variable resistance VR1. At this time, be sure to use cross-shaped driver of a
proper size. Excessive force or improper tools can damage variable resistance.

⑵ Layout and function of DOA-100 PCB

※ 외형도

※ Function
① Variable resistance VR1 : If letters in LCD
are not clear, turn this right and left.

② LCD : Displays letters.


③ KEY PAD : Responding speed of key pad can be
delayed a little. Be sure to verify that

key input appears on LCD.


④ CN2 connector : Connect to DOC-100 PCB.

- 26 -
4) DOP-100 PCB

⑴ DOP-100 PCB

DOP-100 is the power source PCB of DI l(60~105) E/L. This is the source of

DC 24V(Car LON PCB), DC 48V (Relay,outer signal input I/F power), DC110V(C1ST,

C1BR, C1VD contactor power) and AC power source and fuse. This also displays the fuse

condition.

① Applicable drawing
Type Assembly drawing Application
DOP-100 3X03196*A With a fuse holder

DOP-110 3X03411*A Without a fuse holder

② Outside view(SIZE : 140*270) of DOP-100 PCB

(Fig. 1) Layout of D0P-100 PCB

- 27 -
③ Function Layout

For driving For driving For driving For driving For car LON For driving For driving
For car LON Ry/input buffer
brake/contac'r Ry/input buffer brake/contac'r DC 24V INV FAN DOOR motor
AC 100V

For HALL SMPS, AC 220V For DOC-100,DPC-100 B/D


SMPS, AC 110V

For HALL SMPS in 17


Fls or more, AC 220V

For light supplied from building


side, AC 220V

Note1) All LEDs are normal if power ON, abnormal if OFF.


Note2) Connector usage

Secondary side power of Fuse secondary side 3-phase rectifier output


TRANS for CTRL
power (AC power) power(DC power)
(Fuse, primary side)

Fig. 2. Function Layout of DOP-100

Note1) UA connector is the secondary AC power of TRANS controller power fuse.

Note2) UC connector is AC power for car lights and, in case of 16 floors or more,

the hall SMPS.

- 28 -
⑵ Input/Output of DC voltage
Output (v). AC input FUSE LED Diode
FUSE ZNR Load
Connector Pin Connector pin Cap. (DC) Module

DC 110V 3Φ85V 3A LED1 DM1 ZNR1 -.BRAKE COIL,

UB-03 PB-07, FS1 LED2 DF20DB80 271 -.C1ST contactor driving

10,11. FS2 (LED7) -.C1BR contactor driving

-.C1VD contactor driving

DC 48V 3Φ37V FS3 3A LED3 DM2 ZNR2 -.Relay driving, outer input

UB-04 PB-01, FS4 LED4 DF20DB80 221 -.I/F signal, switch input

09,12. (LED8)

DC 24V 3Φ18V FS5 3A LED5 DM3 ZNR3 -.CAR LON PCB power

UB-07 PB-02, FS6 LED6 DF20DB80 221 -.(Uses DC-DC converter)

03,06. (LED9)

Note) Name of LED in parenthises is the LED for DC output display.

⑶ Input/Output of AC voltage
Input connector pin
Fuse
Voltage Fuse LED Load
Capacity
Output connector pin

AC 110V PA-01,09 FS11 3A LED14 -.DOC-100, DPC-100 PCB

UA-07,09 -.SMPS

-.GATE TRANS input power

AC 220V PA-02,06 FS10 5A LED13 -.HALL SMPS input power

UA-06,05 (16 floors or less)

3Φ100V PA-10,11,03 FS8 3A LED11 -.Door motor


UA-02,03,04 FS9 LED12 -.INV. PCB driving SMPS

AC 100V PA-04,12 FS7 3A LED10 -.INV FAN,H/L,CVT driving


UA-01,08

AC 220V UC-08,09,03 FS12 10A LED15 -.Power for lights, supplied

UC-04,05 from building

AC 220V UC-06,02 FS13 5A LED16 -.HALL SMPS input power

UC-07 (16 floors or more)

- 29 -
5) DPC-100 PCB

⑴ Configuration drawing of DPC-100 PCB

DPC-100 PCB 외형도 Power


전원 감시 및
monitoring
OSC DSP CPU RESET
& CPU
33 ㎒ TMS320C31-40 회로
RESET

RAM
EEPROM
KM68257CP-15
AM29F010
×4

C1VD
C1VD
HALL CT A/D DRIVER
CONTACTOR
I/F CONVERTER
AD7891AS-1
8CHANNEL To
DPPDPP
board
BOARD로
ASIC
MAIN
Main INVERTER-01
PCB HEX
PCB
COM. SWITCH
통신 & 및 CF59005PCM
IOIF
IOIF
RS-422 ALP
ALP COM.
통신
D/A
I/F for 26PIN
회로
S/Hcircuit
SH
To AD7891
AD7891
D/A
CARD 용 AS-1 로
AS-1
CARD CONNECTOR
I/F
ENC-A
ENC-B
MON D/A
CHECK CONVERTER ENCODER
PIN DAC0800LCN

PC SERIAL EMUHEAD
EMULATOR
I/F 12PIN Header

- 30 -
⑵ Diagram of DPC-100 PCB

DPC-100

VA

VF
Seg. Function Remarks
+5V +15V -15V GND
VR1 Power monitoring circuit setting 4.7∼5.3[V]

VR1
MON
+5V-CHK
Seg. Connector function Remarks
/IAS_CHK

CHK
VB

VA POWER(+5,±15,GND) Low speed


VF POWER(+5,±15,GND) Mid speed /IBS_CHK
VB HALL CT /ICS_CHK
VC C1VD driving GND
VD ALP driving GND
VE IO/IF(DOC-100 connection)
VG DPP-100 connection
VH SERIAL PC booting
VDA D/A CARD connection Measu.signal

VG
VC

LED state
○ OFF ● ON
VD

⊙ Flicker

VH
LED Indication Function Remarks
○ Normal H/W error LED1
ALM

ALM
● Error detection detection Red
⊙ Normal If 2 or 3
LED2
CPU error flickers per
CPU ○ CPU error

CPU
MON ● CPU error
detection 1sec. It is
normal
Green
VE

Seg. Function MON


MON CHK PIN output CTRL variable setting

2
1

Pin No. Function(J5H) D/A CARD 26 2


J5H

1↔2Pin IGBT 75,150[A]


VDA

3↔4Pin IGBT 100,200[A]


25
1

J1F : For R&D Pin No. Function(J1J) Remark


J1F

J1J

1↔2Pin S/W booting


3↔4Pin EEPROM Write
5∼20 Spec. setting
11

12

19

20

- 31 -
⑶ Check connector connection before power input

① In case of 60~105m/min, verify that connector VA(Control power), VB(CT),

VC(C1VD), VE(1/0,1/F), VG(GDC) are connected.

※ VD(Used for ALP function), VDA(D/A CARD), VH(SERIAL)

and VF(Control power for 120~150m/min) are not connected.

⑷ Check J5H Jumper

① Verify that, J5H JUMPER, inverter H/W over-current detector, are set according to the table below.

Table 1) Setting of J5H Jumper


Jumper No. IGBT Capacity Motor Capacity

No. 1 ~ 2 75A, 150A 4.4KW~7.5KW. 13KW~15KW

No. 3 ~ 4 100A, 200A 9.5KW~11KW. 18KW~22KW

Ex.)13/15KW(for 90~105m/min): a)'13' represents the motor capacity for 90m/min .

b) '15' represents the motor capacity for 105m/min.

※ If both jumpers are not inserted, H/W error will occur.

⑸ Check J1J Jumper

① Insert for 19~20 pin, and the others not inserted.

⑹ Check variable resistance VR1 setting(Factory setting)

① Variable resistance VR1 is a voltage setting volumn for power monitoring and shall

be within +4.7V~+5.3V. As this is set in the factory, modification is usually

unnecessary. If VR indicator is not on black marking, position it on the marking.

⑺ Check control power when inputting power

① As power voltage is set in the factory, checking is usually unnecessary.

If circuit operation is abnormal, check the voltage according to the table 2.

If the measured value is out of the regular range, never reset the value, and

measure again with another instrument in case of measuring equipment failure.

- 32 -
Table 2) Power input terminal
Measuring point Voltage Error correction
VA (+5V - GND) DC + 5V ± 5% 1. Verify that AC 100V is applied

VA (+15V - GND) DC +15V ± 5% to SMPS power input terminal


VA (-15V - GND) DC -15V ± 5% 2. Adjust with volume in SMPS.
3. If still not adjustable, replace SMPS.

⑻ Check WDT

① Verify that LD2 CPU LED(Green) flickers at 0.5 second interval with power ON.

② The LED flickers at 0.25 second interval in motor operation.

Caution: WDT(WATCH DOG TIMER) monitors that the program calculation of speed

control CPU operates properly. If WDT does not flicker at 0.5 second interval

during adjustment or it remains ON or OFF the speed control CPU may

seriously fail. Thus every error shall be inspected thoroughly.

③ In such case, check 5V power, ROM or ROM socket error, or connector connection

error.

⑼ Check ALM LED

① Verify that LD1 ALM LED(Red) turns ON, and then,OFF after about 2 seconds. ALM

LED is for inverter H/W safety check and turns ON when the followings are detected.

a) Overcurrent is detected in inverter.(or J5H Jumper is not inserted)

b) WDT of speed control CPU has failed.

c) IGBT U-phase ARM is short-circuitted and GATE Trans power has failed.

d) IGBT V-phase ARM is short-circuitted and GATE Trans power has failed.

e) IGBT W-phase ARM is short-circuitted and GATE Trans power has failed.

f) Overcurrent is detected on DC Link end.

g) Regenerative IGBT and GATE transformer power have failed.

Caution: If ALM LED turns ON in inputting power and does not turn OFF, operation is

impossible. Perform an inspection according to the above a)~g) as shown below.

- 33 -
②Verify that J5H Jumper is properly inserted.(If not inserted,ALM LED turns ON)

③ Verify that WDT LED turns ON and OFF normally.

④ In c) ~ g) cases, check the connectors of DPP-10X PCB and verify that

GATE turns input is applied by AC 110V±10%.

⑤ Check IGBT stack for connection conditions(disconnection and loose bolts)

⑽ Check C1VD contactor input

① Verify that C1VD contactor input is about 3 seconds after power input.

Caution: If DC Link volt. does not reach 330V even after 8 sec. (Low-

voltage error), turn OFF C1VD contactor and then ON. Then, check the

voltage after 8 seconds. If the voltage is still low, turn OFF the

contact and generate charging circuit failure error.

② In this case, main power circuit connection, GATE Trans input or connection,

charging circuit OFF, or regenerative IGBT ON may have failed. Thus, check

these conditions.
⑾ Check pin and rotary switch
① There are check pin and rotary switch in DPC-100 PCB for maintenance and

installation. The following signals are allocated to check pin.

PIN No. Function

PIN 1(MON) Internal variable outputting signal(Variable is assigned by rotary switch)

PIN2(+5V-CHK) Sets VR1 for monitoring the 5V power(Factory set)


PIN3(/IAS_CHK) Reverse(-) value of motor U-phase current
PIN4(/IBS_CHK) Reverse(-) value of motor V-phase current

PIN5(/ICS_CHK) Reverse(-) value of motor W-phase current


PIN6 No connection
PIN7, 8 GND

- 34 -
② If rotary switch(MON) is set as follows, the control variable of the below

table will be output to P1N1(MON).


Table) Rotary switch variable allocation chart.
HEX SW val Control Variable Remarks Scale Factor
0 0 is output to D/A converter 00H 0
1 +Vmax is output to D/A converter 7FH Vmax
2 -Vmax is output to D/A Converter 80H -Vmax
3 Run control speed command value m-speedr-cmd 14×127/Vmax[rpm]
4 Speed control command value m-speedr-ref 14×127/Vmax[rpm]
5 Actual motor speed m-speedr 14×127/Vmax[rpm]
6 Torque current command value m-iqse-ref 2×127/Vmax[A]
7 Exciting current command value m-idse-ref 2×127/Vmax[A]
8 Max.value of absolute value of ia, ib, and ic m-iabc-peak 2×127/Vmax[A]
9 a-phase current value m-ias 2×127/Vmax[A]
A b-phase current value m-ibs 2×127/Vmax[A]
B Actual exciting current value m-idse 2×127/Vmax[A]
C Actual torque current value m-iqse 2×127/Vmax[A]
D Torque current error value m-iqse-err 0.5×127/Vmax[A]
E Each phase's max.current value filter output ocr-filter-out 2×127/Vmax[A]
F U-phase voltage command value m-vas-ref 3×127/Vmax[A]

※ Calculate actual output variation value from PIN1 output voltage, using scale
factor. Units are shown in the above table.
Output variable = (Output voltage measured) × (Scale factor)
※ MON signal and each phase current value measured by rotary switch can be
referred at trobleshooting and installation. Each signal is connected serially by high
voltage and outputs to each pin. Though there is short-circuitted between two pins,
inverter makes no serious abnormal operation. But, be careful of short-circuitted.

⑿ Cautions for adjusting of speed control gain value


① Adjusting of speed control gain value affects riding comfort and leveling accuracy of the car.

② Use accelerator to change gain.

③ Speed control gain can be changed within -50 % ~ 150 %.(Refer to Annunciator data)

④ High gain value causes excessive vibration and low gain value causes stalling

or starting shock.

- 35 -
6) DPP-10X PCB
⑴ Function

※ As DPP-10X PCB is located in the back of DPC-100 PCB, visual inspection is

difficult. Thus, when ALM LED(Red) of DPC-100 PCB turns ON or when inverter

molfunctions, check DPP-10X PCB after removing the setscrew.

Diagram of DPP-10X PCB(2R24788*A IGBT 150 or less, 2R24788*B IGBT 150 or more)

GLX No. Function (TP7)


1Pin Regen.IGBT +15V power
17 10 2Pin Regen.IGBT - 9V power
9 1 3Pin Regen.IGBT Gate output
4Pin Regen.IGBT Ground

1 4

6
1
1

TP7
To VG7 CONNECTOR

GP
of DPC-100 PCB TP6
1 4

9
5
No. 기
Function 능 Remarks

5
1
VA

1Pin Lower Arm +15V power TP5


TP4:U-phase
2Pin Lower Arm - 9V power 1 4
30
29

TP5:V-phase

GU
3Pin Lower Arm Gate output TP6:W-phase
4Pin Lower Arm Ground
TP4

4
7
1 4

VR2
Overcurrent setting
OV

VR(detected at 770V) TP3

5
1
1 4
Regen. volt. setting
BR

GV
VR(700∼730V regen.)
VR1 No. Function Remarks
Red
Caution 1Pin Upper Arm +15V power
TP1:U-phase
TP2
LED1

7
4
Don't touch stack when 2Pin Upper Arm - 9V power
TP2:V-phase
CHG

light ON after power OFF.


3Pin Upper Arm Gate output 1 4
TP3:W-phase
1

4Pin Upper Arm Ground


6

Seg. Function
ON DC Link end, 50V or less
GW

OFF DC Link end, 50V or less


TP1
1 4
DPP -10x 10

9
5

Seg. CONNECTOR func. Seg. CONNECTOR func. Seg. CONNECTOR func.


GXW Separate power W- GU U- IGBT signal GP
Regen.IGBT signal
Temp. SW(radiator)
GXV Separate power V- GV V- IGBT signal Power supply(each phase)
GXU Separate power U- GW W- IGBT signal GLX (separate TRANSE)

1 3 1 3 1 3
4 5 4 5 4 5
GXU GXV GXW

- 36 -
⑵ Main performance

Item Performance

Detecting short-circuit Detects short within 5us when Arm short-circuit, output short, and

IGBT short by ground fault occur, and outputs an error signal.

GATE soft cut circuit Cuts driving circuit within 10us after a short-circuit is detected.

This process is carried out slowly for 10us to protect IGBT from

spike voltage resulting from short circuit.

Timer & reset circuit When a short-circuit is detected, the timer starts counting at the same time

that GATE cut circuit operates and turns off 1~2ms. Driving output is

cut regardless of the input signal of driving circuit until timer

finishes. When the input signal of driving circuit is OFF after timer

finishes, resetting circuit operates and stops the cut state.

Detecting the power voltage When the power voltage is 22V or less due to power

error circuit failure and power failure, it displays error.

Driving circuit Is able to drive 1200V 400A IGBT with DC 5A driving

capability(In case of M57959L, 100A).

Overheat detection If radiating plate temp. reaches 80 ℃, it detects error.

Power circuit All wave-rectifies 3-phase AC 26V, and then, outputs 24V by constant

voltage regulator, resistance and +15V and -9V to zener diode.

⑶ Variable resistace

① OV variable resistance sets DC Link overcurrent level. The factory setting is 770V.

This setting may be changed temporarily for testing by turning the volume. After testing,

be sure to return the indicator to the black marking.Each end of R31 is 8.02+/-0.5volt.

② BR variable sets regenerative operation starting voltage level. The factory setting is 730V.

This setting may be changed for testing by turning the volume. After testing,

be sure to return the indicator to the black marking.Each end of C12 is 7.6+/-0.5volt.

- 37 -
⑷ Check connector and connection before inputting power

①Checking the type name of DPP-10X PCB according to IGBT capacity shown below.
PCB type name IGBT capacity
DPP-100 75, 100A (or if the max. capacity of

driving motor is 11kW or less)


DPP-101 150, 200A(or if the max. capacity of

motor is over 15kW and below 22kW)

※ HIC1~HIC7 in DPP-100 are all M57959L and, in DPP-101, HIC1~HIC6 are M57962L

and HIC7 is M57959L.

② Check the connection condition of each connector. Verify that all connectors

are connected to their proper positions.

⑸ Check the control power when inputting power

Caution: As DC link voltage is input to DPP-10X PCB after inputting power,

special attention should be paid to safety.

① Usually control voltage needs no checking. If any error is found in circuit

operation, verify that GATE transistor input is within AC110±10% and check

the connectors.

⑹ Verify that charging(discharging) detecting LED lights is ON

① LD1(Red) on PCB lights ON if DC Link voltage is 50V or more and it and dims

(goes) lights OFF if the voltage is less than 50V. LD1 lights ON again when the DC link

begins to be charged with C1VD contactor inputted(connected).

Caution: As it takes about 15 seconds for DC Link voltage to be discharged com-

pletely after power OFF, never touch DPP-10X PCB and stack while LD1 light is ON.

② When LED does not light ON though C1VD contactor is connected with power,

inverter may be short-circuitted, or regenerative IGBT ON, charging circuit OFF or

luminescent diode may fail. Inspection should be carried out after DC link

voltage disconnected.

- 38 -
7) DCL-200 PCB
⑴ Function

※ DCL-200 PCB is car operation board PCB(CLON) mounted with MC143150BIFU


neuron chip and is applied to 60∼240m/min.

① It is installed in the car operation board in a simplex elevator and forms


a serial communication network with CNL LON of control panel.

② Detects call button in car, open, close and exopen(elongates door close time for 3 minutes

and closes the door regardless of door time with a close button registration)buttons, control board switch, on

car connection box switch input, and car load, and it transmits them into 200 PCB, DOC-100 through network.

③ Controls car call B/T, open, close and exopen response lamp and Up/Down
direction lamp, full lamp, CPI, and car-chime(gong) with display commands

through the network of DOC-100, 200 PCB.


④ Functional Classification(DCL-2OO PCB)
No. Classification Item Specification
1 Connection Signal Refer to Table 1∼9.
2 Memory ROM One 27C256 32K Byte
3 Input/Output Input 1) Non voltage switch input by comparator : 39EA
method Car call button input:32 floors(MAX. 64 floors)
Open, close, exopen button: 1 respectively
Up, down, start, bypass button on operating board: 1 respectively.

2) Voltage switch input by comparator : 24


Operating board switch:15. On car connection box switch:5

Car load detecting switch: 3. Photo shoe switch: 1


3) Analog ~ digital converter input: 4 channels
DFTR(Differential transformer): 2
Output 1) TR driving by I/O mapped I/O method: 7
method CPI driving: 3. 110% overload buzzer driving: 1
Chime 1,2 strik driving: 2. LCD back light: 1
2) TR driving by memory mapped I/O method: 39
Car call button response lamp: 32
Open, close and exopen response lamp: 3
Up, down and full lamp on operating board: 3. Button buzzer: 1

4 DC power Voltage +24V±5%


Current TYPE 2 A
5 PCB spec. Size 239×133.3mm
6 Switch SW1 Car operation board ID setting
7 Environment Oper.tem. 0 ℃ ~ 70 ℃

- 39 -
⑵ Diagram of DCL-200 PCB CBL: Connector for 64 fl extention

2 32 VR1:LCD

K
contrast
IND : CPI

D3-V03G
1 31

5
CBL
adjustment

U14-F245
connection V R1-1 0 K

U15-F574
I ND
connector LCD:LCD

AR2 -6. 8K

AR3 -3. 3K
POLY1 -REX-250

AR1-3. 3K
K

16
15
connection

1 TRA5-62083 1

R3-10 1
C37
C3 8 connector

LCD
U9-76C256
LD1:LED for
K
CCN1 : MAIN

U21-75468
CCN1

D1-V03G PCB state


Connector J

R1-270
C1-30P
indication

1
X1 -1 0 MHZ

2
1
DDC -ZS6 2 4 0 5 C3 6
1

C4-470U

C3-100P

-MC34164
SW1:ID setting, R2 -4 7 0 L D1

1
C2 R1

VREF
U4-F32
PST RM-6 4 K
-3 0 P
-GREEN
U1:NEURON

C13

C12
terminal 1
CHIP

17

C14
32
resistandce
U20-F245

-F138
33
1 AR5-3. 3K
SW1

16
C3 3
setting

HI C1-LT78K-E20
RL Y-SY-5 W-K H
1

U2:DCL

U8
C1 1

U2-27C256
48
C3 4

1
BD1

64
DFT R 1 0 U1 -MC1 4 3 1 5 0 C3 2 ROM

49
R7-3. 3K

R6-2. 2K

1 U7 -F 1 3 8

U3 -F04
DFTR :

1 U5-F32
C6 -1 0 U U6 -F0 8
5

R4-2. 2K

-3. 3K

Differen. G
1 U19-ADC10158

C19

1
1
trans. input C8 C7 BD2 C2 8
R5

U12-F574
C3 1 C3 0 C2 9 C2 7

1 U17 -F574

1 U10-F574

1 U11-F574
1

C1 6
F
R11-3. 3K

CI N 24 C1 5 C5
-10U
-2. 2K

BD3 C2 0

1
-2. 2K
12

C2 4
R10

C2 6 C2 5 C2 3 * C1 1 -3 8 :
1 U16-F245

-0 . 1 U
R9 -3. 3K
R8

5
C1 0 C9
C1 8
E LAMP:UP,DOWN,
FULL LAMP
1

U13-F574 1

LAMP
* C15-18: 0. 01U

BD4 C3 5 T RA6 T RA1 T RA2 T RA3


C1 7 * T RA1 -7 : 6 2 0 8 3
AR4-3. 3K * C7-10: 470U

CIN:IN-CAR
* BD1-BD4: SI VB60

(OPB)input D

4 1
OP:OPEN

1
C2 2
B/T & LAMP

OP
C
4 1
1

T RA4
EOP:EX OPEN
13
1

U18 -F574

B
B/T & LAMP
EOP
PL OY2
6

14

HI C7

HI C6

HI C8

HI C9

HI C2

HI C3

HI C4

4 1
HI C5
K

C2 1

ONC:ON- CL:CLOSE
ONC

D2 -V03G

CAR INPUT A B/T & LAMP


TRA7
1

CL
1

* HI C2 -6 : MI B-E0 3
7 * HI C7 -9 : MI A-E0 2 6 5 4 3 2
1

1 CB1 9 1 CB2 9 1 CB3 9 1 CB4 1 9


1

BZ1:CALL
BZ1-BTH-5

B/T BBZZER 1 CL 1 10 1 CL 2 10 1 CL 3 10 1 CL 4 10

DCL-200 3X02457*A
① ② ③ ④ ⑤ ⑥ ⑦ ⑧

① CB1:CALL BUTTON 1~8F ⑤ CB3:CALL BUTTON 17~24F

② CL1:CALL BUTTON LAMP 1~8F ⑥ CL2:CALL BUTTON LAMP 17~24F

③ CB2:CALL BUTTON 9~16F ⑦ CB3:CALL BUTTON 25~32F

④ CL2:CALL BUTTON LAMP 9~16F ⑧ CL2:CALL BUTTON LAMP 25~32F

(Fig.1) Lay out of DCL-200 PCB

- 40 -
⑶ Configuration diagram of DCL-200 PCB

DCL-200 BOARD 구성

NEURON CHIP
PULSE Serial
ROM MAC COMM. Net Work
Process Port TRANS
32K
NetWork
Process
RAM CPI
32K Application CPI 구동
driving
Process I/O
Port
OPB Input CAGE RAM
ON Car Input 2K 전원
Power DC 24
Input supply
WD Input Volt
DDC
DDC

Photo Shoe input EEPROM CLOCK


512B & CTL.

( 제어신호
CTRL signal
) Differen.
차동 TRANS Input
trans input

Lamp Output CAGE


Buzzer Output Output
Chime Output A-D
CONV

For car type DIP DIP


buf
Car Type 설정용
setting LCD Output
S/W

(Fig.2) Configuration diagram of DCL-200 PCB

⑷ DC 24V power input and serial communication

① How to input DC 24V power from control panel and connect serial COM line(CCN1)

※ DCL-200 PCB connection


Setting board of TML R of OPB
OPB1 SUB OPB OPB2 MAIN OPB

DCL-200 DCL-200
Control Panel
DOC-200

CCN1 CCN1
ME- 01
ME

ME- 02
CCN1-01

CCN1-01
CCN1-02

CCN1-02

MIC1 MIC1
APPRATUS BOX RCD
OTHER OPB TAIL CORD Y1-01
Y1 Y1-02

(Fig.3) Setting TML R of OPB

- 41 -
⑸ Car call button input and lamp output

※ Connection of car call button input CB1~CB4 with lamp output CL1~CL4

Down from DC 24V to 0 V when


0 V when B/T lamp ON CALL B/T is registered

CL1 CB1
1 F 1 1 1 F
2 F 2 2 2 F
3 F 3 3 3 F
4 F 4 4 4 F
5 F 5 5 5 F
6 F 6 6 6 F
7 F 7 7 7 F
8 F 8 8 8 F
VCC24 9 9 GND
VCC24 1
10

(Fig.4)
그림Car4-카
call부B/T
름버input
튼 입력& lamp output
및 LAMP 출력

⑹ Operating board switch input


※ Switch of operating board in car and car load detecting device(CIN) inputting
DC 48V
CIN CIN DC 48V
1 SPAR CIN
UP 9
ONCA CALL PRIO 2 1
13
2 1 MAI 5 4 OF
2 HIG
3 NOR 6 O
DN 10 3 OF
3

ONCA FIRE 1 1 2 O 14
2 1 OF 5 4 NOR
3 INCA
3 O 6
STAR 11 3 OF
FIRE 2 1 2 O 15
MAI 4 ONCA
BYPAS 12
2 1
5 ATT RESCUE 2 1
16
3 3

2 1
6 INDE REST 2 1
17
3 S/W ON : 0 V 3

2 1
7 PARK NONSTOP1 18
OFF : 24V
2 1 2 1 OD

3 3 3

2 1
8 EFS NONSTOP2 EV 19
3

WD2 2 1
20
S/W ON : 48V 3

WD8 2 1
21
OFF : 24V 3

WD11 2 1
22
3

(Fig.5) In-car OPB switch input of DCL-200 PCB

⑺ On-car connection box switch(ONC) input


DC 48V ONC
ONCAR SW
2 1 MAINTE 5 4 OFF CLOSE 3
3 NORMAL 6 ON

UP 4

DN 5
S/W ON :48V
OFF :24V

(Fig.6) On-car connection box switch input of DCL-200

- 42 -
⑻ Operating board direction light and car indication lamp output
※ Direction light(UP,DOWN) in operating board and car indication lamp(FULL) output

24V driving
24V

LAMP 4.5
LAMP
UP 1
DOWN 2 FACE LED
FULL 3 750
VCC24 4
LAMP 1 750
VCC24 5

(Fig.7) OPB lamp output

⑼ Chime & gong output


※ When car chime or gong is applied
When gong is applied, be sure to connect the counter-electromotive force preventing diode
outputs (ONC-11) to 48V power, from outside the DCI-200 PCB, in order to prevent DCL-200
PCB from being damaged by counter-electromotive force.
ONC ONC
DC 24 1 VCC 24 1

PIN 9 1 2 PIN 9
GONG
PIN-PON 10 PIN-PON 10

3 Counter-electromotive Force Preventing DIODE output


11 11

1 2 GND 12 GND 12

13 13
4
14 DC 48V 14

When chime applied External connection of PCB


When gong applied

(Fig.8) Chime & gong output of DCL-200 PCB


⑽ CPI output
※ Serial data interface output for CPI driving
DCI-2 X0

DCL- 20 0

BZ1 2 32
6

ENABLE 1 31
CLOCK C
BL
IND

DATA
GND
16
15

VCC24
6 1
CN1

D
LC
C

2
1

D
DC-ZS6 2405
1

HI

(Fig.9) Connection of DCL-200 PCB and CPI

- 43 -
⑾ Differential Trans input

※ Differential Trans input for car load detection


DIFF
1
2 AC 24V INPUT
DFTR
3 CHNNEL1A Changed
AC 4~6V to로AC변화
4~6V
1
4 CHNNEL1B Changed
AC 6~4Vto로
AC변화
4~6V
2
5 CHNNEL2A Changed
AC 4~6Vto로AC변화
6~4V
3
6 CHNNEL2B Changed
AC 6~4Vto로AC변화
6~4V
4
Changed
AC 4~6Vto로
AC변화
4~6V
5
DIFF AC 24V INPUT
Changed
AC 6~4V to로AC변화
4~6V
6
Changed
AC 4~6V to로AC변화
6~4V
1 7 CHNNEL1A
2 Changed
AC 6~4V to로AC변화
6~4V
8 CHNNEL1B
3 9 CHNNEL2A
4 10 CHNNEL2B
5
6

(Fig.10) Input of DCL-200 PCB and differential transformer

⑿ Adjusting LCD output

※ Letters on LCD panel will be cleared by rotating contrast adjusting variable

resistance tap clockwise.

DCL-200
VR for adjusting LCD contrast
K

2 32
5

1 31
U 1 - F 24 5

CB
1 U 1 - F 57 4
D -

VR-1 0K
IN

A R -6. 8K
A R -3. 3K

16
15
A R -3. 3K

K
PO L - R EX -
1

R -1 0 1
C3

C3
1TR -
6

1
1

LC

L CD panel
LCD 판넬
K
CC

1 U -

J
U2 -

C -3 0P
1 D-

R 1-
1

2
1

DD - X- C3
C - 10 0P
C-

-F3 2

C R R -47 0 LD
VR
C1

C1

PS RM- -3 0P -
-
17

16-pin flat cable

(Fig.11) Adjusting LCD output

- 44 -
⒀ Car operating board ID and terminal resistance setting
※ DIP SW1 is used for car operating board ID and terminal resistance setting.
Table 8) Car operating board ID setting
DIP SW 1 Car operating board ID
NO HEX terminal resistance
1 2 3 4 5 6 7 8
1 1 0 0 0 0 0 X X 01 Front side MAIN
2 0 1 0 0 0 0 X X 02 Front side SUB
3 1 1 0 0 0 0 X X 03 Disabled MAIN
4 0 0 1 0 0 0 X X 04 Disabled SUB
5 1 0 1 0 0 0 X X 05 Rear side MAIN
6 0 1 1 0 0 0 X X 06 Rear side SUB
7 X X X X X X X 1 80 TML. R. setting
※ Legend; 0:OFF , 1:ON , X:Ignorance (Note ; TML R : terminal resister)

⒁ Cautions for DIP switch setting

① When setting car operating board ID

Attentions shall be paid so that car operating board ID may be a value among

the above table. Especially the car operating board ID of DCL-100 PCB for on

car operation switch input shall be set as front side of MAIN(01 HEX).

If the setting is other than the above values, communication with DOC-200 PCB of

control panel is impossible. CPI will reset and call will not registered.

② setting a terminal resistance

Terminal resistance is set on the final end of communication line(Refer to Fig. 3).

If a terminal resistance is set on other than the final end of communication

line, DCL-200 PCB, installed on the operating board of the next to where

terminal resistance is set, cannot communicate with DOC-200 PCB. CPI will reset

and call will not register.

- 45 -
⒂ Check LED indication
※ LED-LD1 indicates DCL-200 PCB operation condition as shown below.

NO Indication Conditions required Remarks


1 OFF CPU run error, COM error No P24V power, PCB(H/W) error, etc.

2 ON(1 sec.interval) CPU run normal, COM error Com. line connection error, DIP SW car

operating board ID and TML R setting error

3 ON(0.3 sec.interval) CPU run normal, COM normal

(16) Check car operating board ID and CPI with ANN(Annunciator)

① Enter "A83E" in normal ANN mode.

② ANN displays "CAR CHK" which means car check(Refer to).

③ DCL-200 PCB operates.

④ Car call button of the bottom floor becomes ON and OFF as shown in the

below table according to car operating board ID set in DCL-200 PCB.


NO Car operating board ID(HEX) Light ON number
Table 9)
1 Front side MAIN 1 Once
2 Front side SUB 2 Twice
3 Rear side MAIN 3 3 times
4 Rear side SUB 4 4 times
5 Disabled person MAIN 5 5 times
6 Disabled person SUB 6 6 times
7 7

⑤ The relevant CPI of operating board indicates ID which is set.

⑥ Each lamp(UP,DOWN,FULL,OUT OF SERVICE) of the relevant operating board lights ON in sequence

⑦ Items ④~⑥ are repeated at about 6 seconds interval.

- 46 -
8) DOV-100 PCB(Voice synthesizer)
⑴ Function

DOV-100 PCB is for voice synthesizer.

It is composed of CPU(89C51), RS232C communication section, DA conversion

section, amplification section, and power detection & battery section and others.

⑵ Diagram of DOV-100 PCB

- 47 -
⑶ System configuration
※ DOV-100 PCB configuration
① Com. method: RS232C
② CPU : 89C51
③ MEMORY : ROM(27C040) → Voice data stored
④ D-A converter : Converts digital voice data analog data
⑤ Amplifier:Amplifies analogized data and outputs through speaker(Max.output:2Watt, 8Ω)

⑷ Spec. setting
① Spec. setting method: Spec. can be modified by DIP SW(SW1).
Table) Bit allocation chart
Seg. Bit 1~4 Bit 5 Bit 6 Bit 7 Bit 8
Fun. Refer the below " EX)" ON : 4F is ON : 13F is ON : Chime operates ON : "Thank you"

for Bottom floor setting omitted omitted before broadcasting

Ex.) When 1 2 3 4 5 6 7 8
ON
bottom floor
is B4 OFF

If the bottom floor is 1st floor, please turn off DIP SW No. of 1~4
Ex.) If the bottom floor is B1st floor, trun ON DIP switch 1.
If the bottom floor is B2nd floor, trun ON DIP switch 2.
If the bottom floor is B3rd floor, trun ON DIP switch 1 and 2.
If the bottom floor is B4th floor, trun ON DIP switch 3.
If the bottom floor is B5th floor, trun ON DIP switch 1 and 3.
If the bottom floor is B6th floor, trun ON DIP switch 2 and 3.

※ Once the bottom floor is set, others floors are set automatically.

② Announce recordings in sequence with bit 1~4 turned ON.


Thus, voice synthesizer can be tested with this bit 1~4 in factory or field.
※ Be sure to turn them OFF after testing.

③ Bit 5 and Bit 6 should set same as floor setting spec. of the building.
④ Bit7 sets addition or deletion of chime before broadcasting depending on user's requirements.

⑸ Volume adjusting switch


※ VR1 and VR2 switch controls tone. Make no change of this switch.
① Adjusting method: Turn VR3 to control the volume.
Turn the volume(VR3) up clockwise. (opposite direction to normal volume control)

VR3 changes volume less than usual volume.

- 48 -
⑹ Power failure dectection
DOV-100 PCB detects power failure and announces power failure (twice). As
power failure announcement uses local battery, it starts after 10 minutes
when supplied the battery is charged.

⑺ Power switch
Turns ON and OFF DOV-100 PCB power.

⑻ Indicator(LED1, LED2)
① LED1 : Indicates status of power. Lights ON with power ON.
② LED2 : Indicates the operation status of DOV-100 PCB. This lights ON announcement.

⑼ Connector connection
① SV : For communication ② DV: For power supply and
k
(Connect SV → DOC-100 PCB ST connector) connection
(DV → Power supply for speaker)
PIN NO Function PIN NO Function
1 - 1
2 Rx 2 SPEAKER1
3 Tx 3 SPEAKER2
4 - 4 GND
5 GND 5 DC24V
6 -
7 -
8 -
9 -

⑽ Check points before operation

① Check DV connector for power(24V, GND) connection.

② Check power switch and LED1.

③ Check connection matching transformer and speaker.

(The rating of speaker matching transformer is 16 Ω/8Ω.)

④ Verify that BIT6 in DOC-100 PCB(Spec. setting DIP SW) is ON.

- 49 -
9) DOS-100 PCB(Local monitoring board)
⑴ General
DOS-100 PCB is mounted inside the monitoring board. It is connected to the control panel
(DOC-100, 200 PCB) by a line enabling it to monitor overall elevator conditions.
Contact signal is non-voltage contact and the accepted current is 2 A or less.

① Lay out of DOC-100 PCB(Size 218*280 mm)

② DOS-100 PCB configuration


Block diagram of DOS-100 PCB is as shown below.
DOS-100 PCB

SM connec. in G/A com. MPU & BUS KEEP RY & External


DOC-100 PCB sect. CTRL sect. RY sect. device

③ G/A Communication section


G/A communication section communicates with inside G/A of DOC-100 & 200 through SM connector, decodes
control board information received through communication, and transmits it to MPU in DOS-100 PCB.

④ MPU & BUS control section


The MPU used in DOS-100 PCB is one chip type 89C52. MPU analyzes the data
transmitted from G/A, transmits it to bus controller, and controls relay.

⑤ Keep relay & Relay section


As the relay in DOS-100 is connected to seven segment lamp which shows floor information,
E/L conditions can be informed to monitoring board. As the keep relay(keey type)in
DOS-100 PCB maintains its conditions during power failure,
- 50with
the last condition of E/L can be seen - outside equipment power only.
⑵ Indicator
① Indicator
※ DOS-100 PCB has 2 LEDs.
LED NO Function Indication
LED1 Watch dog run Flickers at 64ms interval with PCB normal
LED2 COM condition indication Flickers at every control panel call (128ms)
⑶ Switch
※ DOS-100 PCB has 2 switches.
Switch Function Remarks
S1 CPU reset
S2 Refer to Table 1. Refer to Table1 and ID set chart.
Table 1) ID setting DIP SW set chart
BIT Function
BIT0 ON: Connects terminal resistance, OFF: Deletes terminal resistance
BIT1 ON: Invalid the call from C.P , OFF: Effective the call from C.P and In normal
BIT2 ON: Voice synthesizer effective , OFF: Invalid Voice synthesizer
BIT3 Plans its application when an option is received.
BIT4 Plans its application when an option is received.
BIT5 Plans its application when an option is received.
BIT6,
OFF,OFF:7-SEG TYPE CPI ; OFF,ON:LAMP TYPE CPI ; ON,OFF:BINARY TYPE CPI
BIT7
⑷ Connector
① PW connector(Power) :No.1=VCC(+ 5V), No.4:GND(0V)
② SM connector(Communication) → Connected to SM connector in DOC-100 PCB.
PIN 1 : Com. line 1 PIN 2 : Com. line 2
③ KA connector(22 PIN) → Connected to other equipment
PIN Usage1 Usage2 Usage3
Ry RELAY DA-
No. (7-CEG type CPI) (Lamp type (Binary type CPI)
No. TYPE TA
CPI)
1 RY1 Keep type D0 7-SEG driving(a) 1st floor LAMP BINARY1
2 RY2 Keep type D1 7-SEG driving(b) 2nd floor LAMP BINARY2
3 RY3 Keep type D2 7-SEG driving(c) 3rd floor LAMP BINARY3
4 RY4 Keep type D3 7-SEG driving(d) 4th floor LAMP BINARY4
5 RY5 Keep type D4 7-SEG driving(e) 5th floor LAMP BINARY5
6 RY6 Keep type D5 7-SEG driving(f) 6th floor LAMP BINARY6
7 RY7 Keep type D6 7-SEG driving(g1) 7th floor LAMP
8 RY8 Keep type D7 7-SEG driving(g2) 8th floor LAMP
9 RY9 Keep type D0 7-SEG driving(A) 9th floor LAMP Upper limit forced reduction error
10 RY10 Keep type D1 7-SEG driving(B) 10th floor LAMP Lower limit forced reduction error
11 RY11 Keep type D2 7-SEG driving(C) 11th floor LAMP Stop between floors
12 RY12 Keep type D3 7-SEG driving(D) 12th floor LAMP Door open unable
13 RY13 Keep type D4 7-SEG driving(E) 13rd floor LAMP Door close unable
14 RY14 Keep type D5 7-SEG driving(F) 14th floor LAMP Starting unable
15 RY15 Keep type D6 7-SEG driving(G1) 15th floor LAMP Bad positioning
16 RY16 Keep type D7 7-SEG driving(G2) 16th floor LAMP Brake operation failure
17 RY17 Keep type D0 7-SEG driving(h,j) 17th floor LAMP
18 RY18 Keep type D1 7-SEG driving(H,J) 18th floor LAMP Failure
19 RY19 Keep type D2 7-SEG driving(N1,N2) 19th floor LAMP
20 RY20 Keep type D3 20th floor LAMP
21 RY21 Keep type D4 21st floor LAMP
22 RY1~RY21 common line RY1~RY21 common line RY1~RY21 common line
Caution: As spec. segment of use1,2 and 3 is input by COM, a separate setting is unnecessary.

- 51 -
④ 7-SEG as configuration.

N1
A a

F B f b
H J h j

G1 G2 g1 g2
C c
E e

N2 D d

Ten 자리
10의 place One 자리
1의 place

⑤ KB connector(22 PIN) → Connected to other equipment


D Usage 1 Usage 2 Usage 3
PIN Ry RELAY A (7-CEG type (Lamp type (Binary type
NO NO TYPE T CPI) CPI) CPI)

1 RY22 Keep type D0 22th floor LAMP


2 RY23 Keep type D1 23th floor LAMP
3 RY24 Keep type D2 24th floor LAMP
4 RY25 Generaltype D3 Unit light Unit light Unit light
5 RY26 Generaltype D4 UP direction light UP direction light UP direction light
6 RY27 Generaltype D5 DN direction light DN direction light DN direction light
7 RY28 Generaltype D6 Safety light Safety light Safety light
8 RY29 Generaltype D7 OUT OF SVC light OUT OF SVC light OUT OF SVC light
9 RY30 Generaltype D0 Fire light Fire light FIRE light
10 RY31 Generaltype D1 Power supply light Power supply light Power supply light
11 RY32 Generaltype D2 Self-generator light Self-generator light Self-generator light
12 RY33 Generaltype D3 OPEN light OPEN light OPEN light
13 RY34 Generaltype D4 CLOSE light CLOSE light CLOSE light
14 RY35 Generaltype D5 MAINT light MAINT light MAINT light
15 RY36 Generaltype D6 OVER LOAD light OVERLOAD light OVER LOAD light
16 RY37 Generaltype D7 AUTOlight AUTO light AUTOlight
17 RY38 Generaltype D0 ATT light ATT light ATT light
18 RY39 Generaltype D1 INDE light INDE light INDE light
19 RY40 Generaltype D2 PARK light PARK light PARK light
20 RY41 Generaltype D3 EME light EME light EME light
21 DN lamp driving
22 RY1~RY21 common line RY1~RY21 common line RY1~RY21 common line
Caution: As spec. segment of usage1,2 and 3 is input by COM, separate setting is unnecessary.

- 52 -
10) DHG-1XX PCB
⑴ Features

This board is mounted with ASIC chip GVC14605 for serial communication only and has
the following features.
- Installed at each hall of single unit composing a serial communication
network together with main board(DOC-100).
- Composes a parallel operation COM network without additional COM board.
- Transmits hall button input and switch input of hall to main board through network.
- Receives the output signal of main board from network and drives hall button
lamp, indicator, hall lantern and hall chime.

(2) Application

Type Application

DHG-130,DHG-150A Applied in case of 1 column parallel operation and separate button type

DHG-140,DHG-150B Applied in case except the above case(Mounted on button box)

(3) Power used

Voltage Usage Remarks

DC24V Drives chime, hall lantern SSR Control board SMPS

IND board power Output power

DC5V Circuit logic power DC24V is dropped to use.

AC100V Drives hall lantern lamp Installed inside of hall lantern board only

(4) Function

① Floor ID setting : Uses DIP switch (DS1-8P)

- Configuration drawing of DIP switch

ON

1 2 3 4 5 6 7 8

Structural
DIPdrawing
스위치 구조도of DIP switch

- 53 -
- DIP switch setting

ON

1 2 3 4

Floor ID setting 설정 value)


Floor ID(Hex 부 버튼type
Button 종류 구분 부
segment
(HEX 값)

- Max. 63 IDs can be set from floor ID set chart(No. 1 ~ 6).

*It is impossible that all are OFF.

- Sets button type using button type segment chart(No. 7 ~ 8).

DIP스위치
DIP swich번호
No. 버튼 종류
Button type
7 8

OFF OFF General


일반 버튼(관통형B/T(through-type
A) A)

ON OFF 관통형 BThrough-type B


OFF ON Disabled
장애자 버튼 person button
ON ON No mode
모드 설정 없음 setting

- Example of DIP switch setting


예Ex.1)
1) 일반형 최하층the
When setting 설정일
IDbotton 경우
F hall B/T(ID=01H)
ID(ID=01H)
ON

1 2 3 4 5 6 7 8

Ex.2) When
예2) 장애자 절대층 disabled person
3 층 ID 설정일 absolute
경우3F ID
(ID=83H)
ON

1 2 3 4 5 6 7 8

Ex.3)
예3) When
관통형through-type
B 절대층 B31absolute
층 ID 설정일31F ID setting(ID=5FH)
경우 (ID=5FH)
ON

1 2 3 4 5 6 7 8

- 54 -
- How to operate DIP switch

DIP switch must be set to OFF position(factory setting) before operation.

DIP switch to ON direction for installation.

Set the bottom floor as 1 and add 1 as the building floor increases by 1.

The floor without button unit passes ID setting(Refer to below table)

Ex.) Floor ID setting of general button type in 15 F(G12, B3) building

건물층수
Fls of B/D 운행층수
Service fls DIP 스위치
DIP 설정(16Value)
S/W setting(Hex. 진 값) 비고
Remarks
12 OK 0D
11 OK 0C
10 NON STOP
non stop 버튼
Wothout 無
B/T unit
UNIIT
9 OK 0B
8 OK 0A
7 OK 09
6 OK 08
5 NON STOP
non stop 버튼 UNIIT
Wothout 無
B/T unit
4 OK 07
3 OK 06
2 OK 05
1 OK 04
B1(지하 층)
B1(und gnd1 1F) OK 03

B2(지하 층)
B2(und gnd2 2F) OK 02

B3(지하
B3(und 층)
gnd33F) OK 01

- Table of floor ID setting by DIP SWITCH(DS1)

1 : ON 0 : OFF

General type floor ID setting

Absol. DIP SW 1 Hex.


Fs value
1 2 3 4 5 6 7 8

1 1 0 0 0 0 0 0 0 1

2 0 1 0 0 0 0 0 0 2

3 1 1 0 0 0 0 0 0 3

31 1 1 1 1 1 0 0 0 1F

32 0 0 0 0 0 1 0 0 20

- 55 -
Floor ID setting of through type rear side

Absol. DIP SW 1 Hex.


Fs value
1 2 3 4 5 6 7 8

1 1 0 0 0 0 0 1 0 1

2 0 1 0 0 0 0 1 0 2

3 1 1 0 0 0 0 1 0 3

31 1 1 1 1 1 0 1 0 1F

32 0 0 0 0 0 1 1 0 20

In case of 2 row parallel operation, ID setting is the same as B side floor.

Assumption : No. 2 row parallel operation by button and through type are incompatible.

<Note>

Floor ID setting for disabled E/L

Absol. DIP SW 1 Hex.


Fs value
1 2 3 4 5 6 7 8

1 1 0 0 0 0 0 0 1 1

2 0 1 0 0 0 0 0 1 2

3 1 1 0 0 0 0 0 1 3

31 1 1 1 1 1 0 0 1 1F

32 0 0 0 0 0 1 0 1 20

② Setting non-service floor

Register non-service floors to spec ROM(EEPROM) in control panel.

Non-Service floors are not serviced regardless of UP/DN Button input.

- 56 -
(5) Communication and power line connection
① Configuration of hall station in case of simplex operation(DI 60~105mpm)
♦ HALL LANTERN
- SSR DRIVE PCB
- UP/DOWN LAMP

♦ 수평형 IND
♦IND(horizontal)

♦ Chime

Power
전원 & com.
& 통신

♦ 수직형 IND
IND(Vertical)
-UP/DN direc. Lamp 방향등
- UP/DOWN
-F indication(segment)
- 층표시(Segment)
-Add'l-fun. indication
부가기능표시등


♦B/TB/T & Controller
& controller
-
-B/TUP/DOWN Button입력
& controller
-UP/DOWN LED출력 스위치
Switch
-UP/DN B/T input
♦UP/DN
♦ GateLED output & HIC
Array
♦Hall
승장입력input
Parking
PARKING
VIP

Max. hall node is 32 in network of simplex operation

② Configuration of hall station in DI 60~105 button 2 row parallel operation network.


MAIN B/D
MAIN B/D #01 E/L
#01호기 MAIN B/D #02
MAIN B/D #02호기
E/L

G/A G/A

Com.
통신 Com. 통신

#01 E/L IND BOARD


#01호기IND. 보드 #02호기IND. 보드
#01호기 #02호기
#02 E/L HALL
#01 E/L HALL Lantern Hall Lantern
랜턴
Hall 랜턴 #02 E/L
#02호기
HALL
HallCHIME
차임

#01호기
#01 E/L
Hall 차임
HALL
CHIME

통신 통신
G/ A Com. Com. G/A
PCB PCB
PCB PCB

TO
다음
NEXT 다음
스위치
SW 스위치
SW TO NEXT FL
층으로
FL 층으로

- 57 -
③ Configuration of hall station in DI 60-105 button 1 column parallel operation network

MAINB/D
MAIN B/D #01
#01 E/L
호기 MAINB/D
MAIN B/D #02
#02E/L
호기
G/A G/A
Com.
통신
#01 E/L HALL #02 E/L HALL
#01호기 #0 2호기
LANTEM
Hall 랜턴 LANTEM
Hall 랜턴
#01#01호기 IND.
E/L IND 보드
BOARD #02#02호기 IND.
E/L IND 보드
BOARD

#01 E/L
#01HALL
호기
Hall 차임
CHIME
#02호기
#02 E/L
Hall 차임
HALL
CHIME
G/A
Com.
통신 다음 층으로
TO NEXT FL
PCB
PCB

PARK
Park
#01 Vip
VIP #02

④ Configuration of terminal resistance and network

- Network configuration for simplex operation


M A IN B /D # 0 1
* M A IN 보 드 내 의 종 단 저항 의 연 결 상태 는
*CONNECTION
T R M 1OFJTML U MR IN
P MAIN 로 변IS경
E R BOARD 함
CHANGED
INTO T 1 有 : 종 단저 항 연 결
R MJUMPER.
TRM1
WITHT TRM1 無R CONNECTION.
R M : 1TRM : 종 단저 항 분 리
종 R단 저 항
TERMINAL -단 독 운
WITHOUT TRM1 전: TRM
시RM A IN 보 드 내 의 T R M 1 J U M P E R 가
DISCONNECTION.
( M A(LOCATED
IN 보 IN드MAIN
내 BOARD)
에 위 치 ) 있 는TRM1
- VERIFY 지 JUMPER
확 인 IS할IN MAIN
것 BOARD WHEN SIMPLEX OPERATION.

H a ll # 3 2

#01 IN D

H a ll # 3 1

H a ll # 2

( 최 하 층LOCATED
분 기IN박 스 에 R종
TERMINAL OF TERMINAL
단저 항 H a ll # 1
내 에 위 치 ) BOX OF BOTTOM FL

- 58 -
- Network configuration drawing for button 1 column(line) parallel operation

MAIN보드
MAIN B/D #01
#01 MAIN 보드
MAIN B/D #02
#02 MAIN B/D 보드
MAIN #01 #01 MAINMAIN 보드 #02
B/D #02

MAIN 보드 #01 TERMINAL


종단저항R
DISCONNECT
내의 TRM1 TERMINAL
종단저항 R
MAIN 보드 #02 내 TRM1
TRM1 JUMPER
Jumper 를 뺀다 VERIFY TRM1 JUMPER IS IN
Jumper가 있는지확인
IN MAIN B/D #01 MAIN B/D #02(If is inserted at
(공장 출하시 꽂혀있음)
the factory)

Hall #32

Hall #32

Hall #31

Hall #31

Hall #2

Hall #2

Hall #1

Hall #1
최하층 IN TERMINAL 종단저항
LOCATED분기박스 R OF TERMINAL TERMINAL
종단저항 R
내에 위치 BOX OF BOTTOM FL

- Network configuration drawing for button 2 column(line) parallel operation(16 floor or less)

MAIN 보드
MAIN #01
B/D #01 MAIN 보드
MAIN B/D #02
#02 MAIN 보드
MAIN B/D #01
#01 MAIN 보드
MAIN B/D #02
#02

MAIN 보드 #01
DISCONNECT
TERMINAL R
종단저항
내의 TRM1 종단저항R
TERMINAL
TRM1 JUMPER VERIFY보드
MAIN TRM1 #02 내 TRM1
JUMPER IS IN
Jumper를 뺀다
IN MAIN B/D #01 Jumper가 있는지확인
MAIN B/D #02(If is inserted at
(공장 출하시 꽂혀있음)
the factory)

Hall #32
Hall #32

Hall #31

Hall #31

Hall #2

Hall #2

Hall #1

LOCATED IN TERMINAL R OF TERMINAL Hall #1


최하층 분기박스 종단저항 종단저항 R
TERMINAL
내에 위치 BOX OF BOTTOM FL

- 59 -
- Network configuration drawing for button 2 column(line) parallel operation(17 F - 32 F)

MAIN B/D #01 MAIN B/D #02

DISCONNECTTRM1
DISCONNECT TRM1
JUMPERININMAIN
JUMPER MAINB/D
B/D#01
#01 DISCONNECT
보드
MAIN #01 MAIN 보드TRM1 #02JUMPER IN
내의 TRM1 내의 TRM1MAIN B/D #02
Jumper 를 뺀다
REPEAT PCB
(INSTALLING AT C.P)

TERMINAL R
Hall #32 Hall #32

Hall #31 Hall #31

Hall #2
Hall #2

Hall #1
TERMINAL R TERMINAL R Hall #1

⑤ Connector name

DHG-130 DHG-140

Name Usage Name Usage

HF1 Unit 1 hall lantern operator HF Hall lantern operator

HF2 Unit 2 hall lantern operator

HC1 Unit 1 hall chime operator HC Hall chime operator

HC2 Unit 2 hall chime operator

HP Parking switch input HB Parking and VIP input

HVF VIP switch input

HA For COM. and power supply HA For COM. and power supply

HI Indicator operator HI Indicator operator

- 60 -
11)DHI-1XX PCB

DHI-1XX PCB indicates the current location of the elevator by means of BCD code

input from DHG PCB.

(1) Function

① Floor indication

▶Signal method : BCD(Binary Code for Digit)

BCD logic configurating EPLD element : EPM7032LC44-15 (Altera Co.)

Working is segmented according to markings as shown below.

- Program marked with M, L in lower SEG: A

- Program marked with b,P in lower SEG: B

Working is segmented with a sticker on EPLD.

Ex.1) EPLD element + A -> Marked with M, L (lower SEG)

Check board marking

DHI-10X -> DHI-100

3x03322*A,B -> 3X03322*A,

Label attached to EPLD : DHI-1X0

Ex.2) EPLD element + B -> Marked with b, P in (lower SEG)

Board marking

DHI-10X -> DHI-101

3x03322*A,B -> 3X03322* ,B

Label attached to EPLD : DHI-1X1

▶ Upper SEG marking : 1 - 5, M, L, G, E, P, F, C, U, B , Blank

▶ Lower SEG marking : 0 - 9, G, H, F, M, L, b, P, Blank

② Direction light and additional function indication light

LED module type with DC 24V driving voltage

- 61 -
(2) Setting slide switch
①Setting for simplex operation(status of factory set)
보드SILK
PRINTED 인쇄SILK
BOARD 상태
S-SW1

1 2 3 1 2 3

#01 #02

② Setting method for duplex operation


#01 E/L IND board: -> Set slide switch to #01 direction(According to printed PCB silk)

#02 E/L IND board: -> Set slide switch to #02 direction(According to printed PCB silk)

1 2 3
1 2 3
SETTING
1 호 기 설#01
정 E/L SETTING
2 호 #02
기 설 E/L정

(3) Configuration of vertical and horizental IND board connector.


콘넥터명
CONNECTOR PIN 번호
PIN NO. 신호명
SIGNAL 신호 설명 DESCRIPTION

1 DC24V DC 입력전원 -> DC5V


DC INPUT POWER 로 제어전원
--> CHANGED INTO DC 5V변환
CTRL POWER

2 D0
3 D1 D7 D6 D5 D4 D3 D2 D1 D0
4 D2
5 D3
6 D4
7 D5 상위세그 하위세그
BCD CODE FOR
표시용 BCD표시용
CODE FOR INDICATING
HI(HI1) 8 D6 INDICATING UPPER SEG.
BCD 코드 LOWER 코드
BCDSEG. (ONE PLACE)
(TEN PLACE)
9 D7 (10 의 자리 ) (1의 자리)

10 CLK1 병렬FOR
SIGNAL 운전 시 호기
IDENTIFYING 구분DUPLEX
E/L WHEN 신호 OPR(CLOCK
(#01 호기FOR
용#01)CLOCK)
11 CLK2 병렬FOR
SIGNAL 운전 시 호기
IDENTIFYING 구분PARALLEL
E/L WHEN 신호 (#02 호기 FOR
OPR(CLOCK 용 #02)
CLOCK)
12 UP DIR 엘리베이터
DRIVING UPE/L방향등
SIGNAL FOR 구동
UP DIRECTION 신호
LAMP
13 DN DIR 엘리베이터
DRIVING DN
SIGNAL FOR 방향등
E/L DN 구동
DIRECTION 신호
LAMP

14 FULL 만원등
DRIVING 구동
SIGNAL FOR신호
FULL LAMP
15 OOS OUT OF SERVICE 등SERVICE
DRIVING SIGNAL FOR OUT OF 구동 LAMP
신호
16 GND
HI2 1-16 수평형 IND 보드에만 해당, 핀구성은 HI 와 동일
APPLIED TO HORIZONTAL IND B/D ONLY, PIN CONFIG. IS THE SAME AS HI.

- 62 -

You might also like