(Objective Evidence has been changed without changing the intent to maintain the confidentiality)
No. Chapter
Standard:
The monitoring shall include the review of customer performance data including
online
Evidence:
In case of customer score card received from HMCL, Maruti, TVS (April 18 to Oct
18) less score received against target, however no analysis evident for the same.
Standard:
Evidence:
In tool / die room – die was not kept as per defined location also some of
discarded dies lying on die rack.
Standard:
The organization shall…. Where applicable, take action to acquire the necessary
competence, and evaluate the effectiveness of the action taken.
Evidence:
Training Effectiveness evaluation was not done for Mr. Vikas Puri for Calibration
training which was conducted on 18th Nov 18
Internal Audit NC Real Examples
(Objective Evidence has been changed without changing the intent to maintain the confidentiality)
No. Chapter
Standard:
Evidence:
On 22nd March 2019 Grinding machine was under breakdown for upper gear box
tooth broker for 10 hrs. and 15 min but no root cause and corrective action plan
is evident for the same.,
Physical stock of critical spare of bearing 8768 required stock is 6 no’s min but
actual observed stock is 5 nos.
Standard:
Evidence:
For Customer complaint from TVS Mootrs on dated 25-04-2016,Part name MMC
rebound /080009-940 regarding Burr ,corrective action taken to change the
process method from Straight cutting to Rotary cutting at coiling machine, but
there is no evidence of change control found for implementing above change,
internal PCN approval for change implementation not available as per internal
work instructions for 4M change control management standard
IATF/SOP/17,rev.01,20-02-2019.change control steps as per internal documented
procedure IATF/SOP/20 not followed.
Internal Audit NC Real Examples
(Objective Evidence has been changed without changing the intent to maintain the confidentiality)
No. Chapter
Standard:
Evidence:
Standard:
Evidence:
MSA Study done for Gauge no. MPC-MM-05 (digital vernier caliper) on
03/05/2017 having Equipment variation of 37.36 % and GRR is 0.92 % but there is
no software validation evident for Excel sheet F-QA-18
Internal Audit NC Real Examples
(Objective Evidence has been changed without changing the intent to maintain the confidentiality)
No. Chapter
Standard:
Evidence:
Standard:
The organization shall monitor & review information about these interested
parties & their relevant requirements
Evidence:
Standard:
Evidence:
And maintenance objectives like MTTR, MTBF & OEE not discussed.