Omron E3Z D62 Datasheet
Omron E3Z D62 Datasheet
Omron E3Z D62 Datasheet
E3Z CSM_E3Z_DS_E_4_1
Features
Industry's Top-level Sensing Distance with Through-beam
Built-in Amplifier
A separately sold filter is available to prevent mutual interference for
Through-beam Models with red lights sources and a sensing
15 m
distance of 10 m. Reflective Models include functionality to prevent Retro-reflective with MSR function Distance-settable
mutual interference.
1m
Low-temperature Operation for Applications in Cold-storage Warehouses
A wider ambient operating range from −40 to 55°C (main models with connectors). We also provide Sensor I/O Connectors with PUR Cables for
high resistance to cold environments.
The offset between the optical axis and the mechanical axis is kept within ±2.5°, so the optical axis can
be accurately set simply by mounting the Sensor according to the mechanical axis. Optical axis
The receiver will always be in the range of light diffusion.
Sensor Protection against Incorrect Wiring Through-beam Model receivers and Reflective Models (except the E3Z-LS)
Brown 12 to 24 VDC
1
The Sensor includes output reverse polarity protection. Operation Stability
indicator indicator
(A diode to protect against reverse polarity is added to the output line.) (orange) (green) 100 mA Load
max. (relay)
Photo- Black
4
electric
Sensor ZD
main Blue
circuit 3
0V
1
E3Z
Ordering Information
Sensors [Refer to Dimensions on page 15.] Red light Infrared light
Model
Sensing method Appearance Connection method Sensing distance
NPN output PNP output
Pre-wired (2 m) E3Z-T61 2M E3Z-T81 2M
15 m
Standard M8 connector E3Z-T66 E3Z-T86
2
E3Z
Infrared
15 m E3Z-T61 ● ● ● ● ● ● ●
light
Through- Red
10 m E3Z-T61A --- ● ● ● --- ● ●
beam light
2-ms re-
30 m E3Z-T62 --- ● --- --- --- --- ---
sponse
Retro- MSR
4m E3Z-R61 ● ● ● ● ● ● ●
reflective function
Wide
100 mm E3Z-D61 --- ● ● ● ● ● ●
view
Diffuse-
reflective Long
(narrow- 1m dis- E3Z-D62 ● ● ● ● ● ● ●
beam re- tance
flective)
Narrow
90 mm E3Z-L61 ● ● ● ● --- ● ●
beam
FGS
200 mm E3Z-LS61 --- ● ● ● ● ● ●
Distance- function
settable Small
80 mm E3Z-LS63 --- ● --- --- --- --- ---
spot
1 optical
E3Z-G61 ● ● ● ● ● ● ●
axis
Slit-type 25 mm
2 optical
E3Z-G62 --- ● ● ● ● ● ●
axes
Retro- 500 mm E3Z-B61 --- ● ● --- --- ● ●
reflective
No MSR
for clear,
2m function E3Z-B62 --- ● ● ● --- ● ●
plastic
bottles
Clamp-type e-CON pre-wired connectors are also available for models shaded in .
Add "-ECON-C 2M" after the basic model number to specify the connectors.
3
E3Z
PNP Output
Model
E3Z-T81 E3Z-T81 E3Z-T81
Model number E3Z-T81 0.5M E3Z-T81 5M
-M1TJ 0.3M -M1J 0.3M -M3J 0.3M
example
M12 pre-wired
Connec- M12 pre-wired M8, 4-pin pre-
Smartclick Pre-wired Pre-wired
tion standard con- wired connec-
connector (cable length: (cable length:
Sens- specifi- nector (cable tor (cable
Sensing Main (cable length: 0.5 m) 5 m)
ing dis- cation length: 0.3 m) length: 0.3 m)
method features 0.3 m)
tance
Basic
model -M1TJ 0.3M 0.5M 5M -M1J 0.3M -M3J 0.3M
number
Infrared
15 m E3Z-T81 ● ● ● ● ●
light
Through- Red
10 m E3Z-T81A --- --- --- ● ---
beam light
2-ms re-
30 m E3Z-T82 --- ● --- --- ---
sponse
Retro- MSR
4m E3Z-R81 ● ● ● ● ●
reflective function
Wide
100 mm E3Z-D81 ● ● ● ● ●
view
Diffuse-
reflective Long
(narrow- 1m dis- E3Z-D82 ● ● ● ● ●
beam tance
reflective)
Narrow
90 mm E3Z-L81 ● ● ● ● ---
beam
FGS
200 mm E3Z-LS81 --- ● ● ● ●
Distance- function
settable Small
80 mm E3Z-LS83 --- ● --- --- ---
spot
1 optical
E3Z-G81 ● ● --- ● ●
axis
Slit-type 25 mm
2 optical
E3Z-G82 --- ● --- ● ●
axes
Retro- 500 mm E3Z-B81 --- ● --- ● ---
reflective
No MSR
for clear,
2m function E3Z-B82 --- ● ● ● ---
plastic
bottles
4
E3Z
Oil-resistive Sensors [Refer to Dimensions on page 15.] Red light Infrared light
Model
Sensing method Appearance Connection method Sensing distance
NPN output PNP output
Pre-wired (2 m) E3Z-T61K 2M E3Z-T81K 2M
Through-beam
(Emitter + Receiver) *3 15 m
Pre-wired M8 connector E3Z-T61K-M3J 0.3M E3Z-T81K-M3J 0.3M
5
E3Z
10.8 4.9
Can be used with the E3Z-T@@A Through-
7.4
1 beam models. The arrow indicates the direc-
Two sets each for the
tion of polarized light. Mutual interference
3m E39-E11 Emitter and Receiver
can be prevented by altering the direction of
(total of four pieces)
31.4 11.2 polarized light from or to adjacent Emitters
0.2 and Receivers.
Mounting Brackets
E39-L104 E39-L150
1 1 set
(SUS304) (SUS304)
(Sensor adjuster)
Compact Protective
E39-L44 E39-L144
1 Rear Mounting Bracket 1 Cover Bracket (For E3Z
(SUS304) (SUS304)
only) *
Note: When using Through-beam models, order one bracket for the Receiver and one for the Emitter.
*1. Refer to Mounting Brackets on E39-L/F39-L/E39-S/E39-R for details.
*2. Cannot be used for Standard Connector models.
5m E39-ECON5M
e-CON 4-wire
Double-end connectors 0.5 to 1 m E39-ECONW@M
1.1 to 1.5 m @ indicates cable length (in units
12 3 4
432 1
2m XS3F-M421-402-L
Straight
PUR 5m XS3F-M421-405-L
M8 (Polyurethane) 4-wire
cable *2 2m XS3F-M422-402-L
L-shaped
5m XS3F-M422-405-L
Note: 1. Refer to Introduction to Sensor I/O Connectors for details.
2. The Sensor can be used in low-temperature environments (−25°C to −40°C). Do not use the Sensor in locations that are subject to oil.
6
E3Z
Ratings and Specifications
Retro-reflective with (Narrow-
Sensing method Through-beam Diffuse-reflective
MSR function beam Models)
NPN Pre-wired E3Z-T61 E3Z-T62 E3Z-T61A E3Z-R61 E3Z-D61 E3Z-D62 E3Z-L61
out-
put Connector (M8) E3Z-T66 E3Z-T67 E3Z-T66A E3Z-R66 E3Z-D66 E3Z-D67 E3Z-L66
Model
PNP Pre-wired E3Z-T81 E3Z-T82 E3Z-T81A E3Z-R81 E3Z-D81 E3Z-D82 E3Z-L81
out-
Item put Connector (M8) E3Z-T86 E3Z-T87 E3Z-T86A E3Z-R86 E3Z-D86 E3Z-D87 E3Z-L86
7
E3Z
The E3Z-T@2-G0 is equipped with an emission stop function. Ratings and specifications of this function are given in the following table.
Sensing method
Item Output and Modes
Through-beam models, NPN output: E3Z-T62/T67-G0, PNP output: E3Z-T82/T87-G0
<NPN models> Emission OFF: Short-circuit to 0 V or 1.5 V max. (Outflow current 1 mA max.), Emission ON: Discon-
nected (Leakage current 0.1 mA max.)
Emission stop Input
<PNP models> Emission OFF: Short-circuit to +DC (Power supply plus side) or +DC-1.5 V max. (Inlet current 3 mA
function max.), Emission ON: Disconnected (Leakage current 0.1 mA max.)
Response time Operate or reset: 0.5 ms max.
Oil-resistant
Sensing method Through-beam Retro-reflective Diffuse-reflective
NPN Pre-wired Models E3Z-T61K E3Z-R61K E3Z-D61K E3Z-D62K
out-
put M8 Pre-wired connector E3Z-T61K-M3J E3Z-R61K-M3J E3Z-D61K-M3J E3Z-D62K-M3J
Model
PNP Pre-wired Models E3Z-T81K E3Z-R81K E3Z-D81K E3Z-D82K
out-
Item put M8 Pre-wired connector E3Z-T81K-M3J E3Z-R81K-M3J E3Z-D81K-M3J E3Z-D82K-M3J
3 m (150 mm) *
100 mm 1m
(when using E39-R1S)
Sensing distance 15 m (white paper: 100 × (white paper: 300 ×
2 m (100 mm) *
100 mm) 300 mm)
(when using E39-R1)
Spot diameter ---
Standard sensing object Opaque: 12-mm dia. min. Opaque: 75-mm dia. min. ---
Minimum detectable object ---
Differential travel --- 20% max. of setting distance
Both emitter and receiver:
Directional angle 2 to 10° ---
3 to 15°
Light source (wavelength) Infrared LED (870 nm) Red LED (660 nm) Infrared LED (860 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
35 mA max. (Emitter:
Current consumption 15 mA max., Receiver: 30 mA max.
20 mA max.)
Load power supply voltage: 26.4 VDC max., Load current: 100 mA max.
Residual voltage: Load current of less than 10 mA: 1 V max.
Control output Load current of 10 to 100 mA: 2 V max.
Open collector output (NPN/PNP depending on model)
Light-ON/Dark-ON selectable
Reversed power supply
polarity protection, Output
Reversed power supply polarity protection, Output short-circuit protection, Mutual in-
Protection circuits short-circuit protection,
terference prevention, and Reversed output polarity protection
and Reversed output po-
larity protection
Response time Operate or reset: 1 ms max.
Sensitivity adjustment One-turn adjuster
Incandescent lamp: 3,000 lx max.
Ambient illumination (Receiver side)
Sunlight: 10,000 lx max.
Ambient temperature range Operating: −25 to 55°C, Storage: −40 to 70°C (with no icing or condensation)
Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection IP67 (IEC), Oil resistant models: IP67 (IEC) (in-house standards: oilproof), excluding cables and connectors
Connection method Pre-wired cable (standard length: 2 m), M8 Pre-wired Connector
Operation indicator (orange)
Indicator Stability indicator (green)
Emitter has power indicator (orange) only.
Weight Pre-wired cable (2 m) Approx. 120 g Approx. 65 g
(packed
state) Connector (M8, 4 pins) Approx. 50 g Approx. 30 g
Case PBT (polybutylene terephthalate)
Material
Lens Modified polyarylate Methacrylic resin Modified polyarylate
Accessories Instruction manual (Neither Reflectors nor Mounting Brackets are provided with any of the above models.)
* Values in parentheses indicate the minimum required distance between the Sensor and Reflector.
8
E3Z
Engineering Data (Typical)
Distance Y (mm)
1000
Distance Y (mm)
1000 2.0
800 800 Y
1.5
600 600 X
1.0
400 400
0.5
200 200
0 0 0
10 20 30 40 10 20 30 40 10 20 30 40
Distance Distance Distance
−200 −200
X (m) X (m) −0.5 X (m)
−400 −400
−1.0
−600 −600
Y
−1.5
−800 −800
X
−1000 −1000 −2.0
Distance Y (mm)
250 200
Distance Y (mm)
200
Distance Y (mm)
E39-R1K E39-R10
Y
200 Y Y
150 150
E39-R3 X
150 X X
100 100
100
50 50
50
Distance X (m)
0 0 0
1 2 3 4 5 1 2 3 4 5 2 4 6 8
Distance Distance
−50
X (m) −50 X (m) −50
−100 E39-S65B E39-S65B
E39-S65C −100 −100
−150 E39-S65C
E39-S65D E39-S65D
−150 −150 E39-R9
−200 E39-S65E E39-S65E E39-R2
E39-S65F E39-S65F E39-R1 E39-R1S
−250 −200 −200
Operating Range
Diffuse-reflective Models Diffuse-reflective Models Narrow-beam Reflective Models
E3Z-D@1(D@6) E3Z-D@2(D@7) E3Z-L@1(L@6)
Distance Y (mm)
80
Distance Y (mm)
Sensing object: 300 × 300 mm white paper Sensing object: 100 × 100 mm white paper
white paper Y
60 8
Y Y
20
X 6
40
X X
10 4
20
2
0 0 0
50 100 150 200 250 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 50 100 150 250
Distance Distance 200 Distance
X (m) −20 −2
−10
X (m) X (m)
−4
−40
−20 −6
−60
−8
−30 −80
−10
9
E3Z
E39-R9 30
E39-R1K
E3Z-T@2 (T@7)
10 10 10
E39-R10 7
E3Z-T@A
5
E39-R1S
3
E39-R2
1 1 Operating 1
E39-R3 level 0.7
E3Z-T@1 (T@6) 0.5
0.3
E39-R1
100
70 Sensing object: 300 × 300 mm white paper 70
50 50
30 30
10 10
7 7
5 5
3 3
Operating 1 Operating 1
level level
0.7 0.7
0.5 0.5
0.3 0.3
0.1 0.1
0 0.5 1 1.5 2 2.5 3 0 50 100 150 200 250 300 350
Distance (m) Distance (m)
10
E3Z
Distance (m)
4.5
Distance (mm)
Distance (m)
300
d White paper d
4
300
d d 250
SUS
3.5
SUS (glossy surface)
250 (glossy surface)
3 200
200 2.5
150
150 2
1.5 100
100
White paper
1
50 Black paper 50
0.5 Black paper
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 0 1 2 3 5 7.5 10 20 30 100
Side length (one side) of Side length (one side) of × × × × × × × × ×
sensing object: d (mm) sensing object: d (mm) 1 2 3 5 7.5 10 20 30 100
Side length (one side) of
sensing object: d (mm)
Spot Diameter vs. Sensing Distance Differential Travel vs. Sensing Distance
Narrow-beam Reflective Models Narrow-beam Reflective Models
E3Z-L@1(L@6) E3Z-L@1(L@6)
Differential travel (mm)
Spot diameter (mm)
4.0 30
3.5
25
3.0
20
2.5
2.0 15
1.5
10
1.0
5
0.5
11
E3Z
I/O Circuit Diagrams
NPN Output
Operation Operation
Model Timing charts Output circuit
mode selector
Incident light Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models.
No incident light
Operation Brown 12 to 24 VDC
ON Operation 1
indicator OFF indicator Stability
(orange) L side indicator 100 mA Load
Light-ON Output ON (Control
transistor OFF
(LIGHT ON) (Orange) (Green)
output) Black
max. (Relay)
Photo- 4
E3Z-T61(K) Load Operate electric
(e.g., relay) Reset Sensor ZD
E3Z-T66 (Between brown (1) and black (4) leads)
main Blue
circuit 3
E3Z-T62 0V
Incident light
E3Z-T67
No incident light
E3Z-T61A Operation ON Connector Pin Arrangement e-CON Connector Pin Arrangement
E3Z-T66A indicator
OFF 1 Press fit
1
Clamp
(orange) D side
E3Z-R61(K) Dark-ON Output ON 2 4
2 2
transistor (DARK ON) 1 3
E3Z-R66 OFF
Operate
E3Z-D61(K) Load
3
(e.g., relay) Reset 3
E3Z-D66 Pin 2 is not used. 4
(Between brown (1) and black (4) leads) 4
E3Z-D62(K)
E3Z-D67 Through-beam Emitter Brown
Connector Pin e-CON Connector
1
E3Z-L61 Power Arrangement Pin Arrangement
indicator
E3Z-L66 (orange) 1 Press fit
1
Clamp type
Photo-
electric
2 4 2 2
12 to 1 3
Sensor
24 VDC
main
circuit 3 3
Pins 2 and 4 4 4
3
Blue are not used.
Through-beam Emitter
Power indicator Brown 12 to 24 VDC
Emission ON 1
stop input OFF (Orange)
Connector Pin Arrangement
E3Z-T62-G0 (Between blue (3) and pink (2) leads)
Photo-
--- ON --- electric Pink
E3Z-T67-G0 LED for
emission OFF Sensor 2
(Emission
2 4
main 1 3
circuit stop input)
Indicator ON
(orange) OFF
0V
3
Pin 4 is not used.
Blue
PNP Output
Operation Operation
Model Timing charts Output circuit
mode selector
Incident light
Through-beam Receivers, Retro-reflective Models,
No incident light
Operation ON
Diffuse-reflective Models
indicator OFF Brown 12 to 24 VDC
(orange) L side Operation 1
Light-ON Output ON indicator Stability
transistor OFF
(LIGHT ON) indicator
(Green) ZD
Operate (Orange)
E3Z-T81(K) Load Black
(e.g., relay) Reset Photo- 4
electric
E3Z-T86 (Between blue (3) and black (4) leads) Sensor
(Control 100 mA Load
main output) (Relay)
E3Z-T82 circuit Bluemax.
3
Incident light
E3Z-T87 0V
No incident light
E3Z-T81A Operation ON
E3Z-T86A indicator OFF Connector Pin Arrangement
(orange) D side
E3Z-R81(K) Dark-ON Output ON
(DARK ON) 2 4
E3Z-R86 transistor OFF 1 3
Through-beam Emitter
Power indicator Brown 12 to 24 VDC
Emission ON 1
(Orange)
stop input OFF Connector Pin Arrangement
E3Z-T82-G0 (Between brown (1) and pink (2) leads) Photo- (Emission
--- ON --- electric stop input)
E3Z-T87-G0 LED for
emission OFF
Sensor 2 2 4
main Pink 1 3
circuit
Indicator ON
(orange) OFF 0V
3
Pin 4 is not used.
Blue
12
E3Z
432 1
fication No.
4 2 1 Brown
3 1
2 White Brown 1 Power supply (+V)
3 Blue E39-ECON@M
4 Black White 2 (Emission stop input)
DC
Blue 3 Power supply (0 V)
XS3F-M421-402-A Black 4 Output
432 1
XS3F-M421-405-A
XS3F-M422-402-A Note: Pin 2 is not used.
XS3F-M422-405-A E39-ECONW@M
Nomenclature
Through-beam Models
E3Z-T@@ (Emitter)
E3Z-T@@A (Receiver)
Stability indicator Operation indicator
Retro-reflective Models (green) (orange)
E3Z-R@@ Sensitivity adjuster
13
E3Z
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring ● Oil-resistant Models
safety of persons either directly or indirectly. Oil Resistance
Do not use it for such purposes.
• Although the E3Z-@@@K Sensors have oil-resistant specifications,
performance may be affected by certain types of oil. Refer to the
following table.
Precautions for Correct Use • E3Z-@@@K Sensors are tested for resistance to the oils given in
Do not use the product in atmospheres or environments that exceed the following table. Refer to the information in the table when
product ratings. deciding which type of oil to use.
● Wiring Kinematic
Test oil clas- viscosity
M8 Metal Connector Product name pH
sification (mm2/s)
• Be sure to connect or disconnect the metal connector after turning at 40°C
OFF the Sensor. Lubricant Velocity No.3 2.02
• Hold the connector cover to connect or disconnect the metal Water insolu- ---
connector. ble machining Yushiron Oil No.2 ac Less than 10
• Secure the connector cover by hand. Do not use any pliers, oil
otherwise the connector may be damaged. Yushiroken EC50T-3 7 to 9.5
• The proper tightening torque range is between 0.3 and 0.4 N·m. Be Water soluble Yushiron Lubic HWC68 7 to 9.9
sure to tighten the connector securely, otherwise the specified ---
machining oil Gryton 1700D 7 to 9.2
degree of protection may not be maintained or the connector may
Yushironken S50N 7 to 9.8
be disconnected due to vibration.
Note: 1. The E3Z maintained a minimum insulation resistance of 100 MΩ after
it was dipped in all the above oils for 240 hours.
● Mounting 2. When using the Sensors in environments subject to oils other than
Sensor Mounting those listed above, use the figures for kinematic viscosity and pH from
the table as general guidelines. Additives and other substances
Use M3 screws to mount the sensor and tighten each screw to a contained in oils may affect the E3Z. Be sure to consider this before
maximum torque of 0.53 N·m. use.
14
E3Z
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
Through-beam 20
8 Press-fit e-CON Pre-wired Connector
Pre-wired Models (Excluding -G0) 5.9
E3Z-T61(K) Emitter 10.8 10.4 Terminal Specifica- 1
E3Z-T81(K) No. tions 2
3
15
E3Z-T61A Power indicator (orange) 1 +V
15.6
4
7.2 17
E3Z-T81A Lens
2 --- *4-dia. vinyl-insulated round cable with
Optical axis 2.1 2 or 3 conductors,
E3Z-T62(-G0) 3 0V Standard lengths: 0.3 m, 0.5 m, and 2 m
E3Z-T82(-G0) 4 ---
18 11 31 25.4 Clamp-type e-CON Pre-wired Connector
Pins 2 and 4 are not used.
15.5 (E3Z-T61-ECON-C) 6
(-G0)
1
Two, M3 Terminal Specifica- 2 15.8
3
4-dia. vinyl-insulated round cable with 2 No. tions 4
conductors (Conductor cross section: 1 +V 18
0.2 mm2 (AWG24), Insulator diameter: *4-dia. vinyl-insulated round cable with
1.1 mm), 2 Input 2 or 3 conductors,
Standard length: 2 m Standard length: 2 m
3 0V
4 --- M12 Pre-wired Connector
(E3Z-T@@-M1J)
Pin 4 is not used. *4-dia. vinyl-insulated round cable with
2 or 3 conductors,
Standard length: 0.3 m
20 4
12.45 1
8.8
Power indicator (orange)
3
4.3 2
3.2 M12 × 1
Receiver 10.8 10.4 M8 Pre-wired Connector
Operation selector
(E3Z-T@@K-M3J)
Stability indicator (green)
Sensitivity adjuster
7.2 17 *4-dia. vinyl-insulated round cable with
Terminal Specifica- 2 or 3 conductors,
Lens 2.1 No. tions Standard length: 0.3 m
Optical axis 2 4
1 +V
18 11 31 25.4
2 --- 1 3
15.5
3 0V M8
4 Output * The Emitter cable has two conductors and the
Receiver cable has three conductors.
Two, M3 Pin 2 is not used.
4-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section:
0.2 mm2 (AWG24), Insulator diameter: 1.1 mm),
Standard length: 2m
Through-beam 20
8
Connector Models
E3Z-T66 Emitter 10.8 10.4
(Excluding -G0) (-G0)
E3Z-T86 Power indicator (orange) Terminal Specifica- Terminal Specifica-
E3Z-T66A 7.2 17 No. tions No. tions
E3Z-T86A Optical axis
Lens 2.1 1 +V 1 +V
E3Z-T67(-G0) 2 --- 2 Input
E3Z-T87(-G0) 18 11 31 25.4 3 0V 3 0V
15.5 4 --- 4 ---
Pins 2 and 4 are not used. Pin 4 is not used.
Two,
10.4 M3
M8 connector
9.75
20
12.45
8.8
Power indicator (orange)
4.3
3.2
Receiver 10.8 10.4
Terminal Specifica-
Stability indicator (green) Operation selector No. tions
Sensitivity adjuster 1 +V
7.2 17
Lens 2 ---
Optical axis 2.1
3 0V
4 Output
18 11 31 25.4
Pin 2 is not used.
15.5
10.4 Two,
M3
M8 connector
9.75
15
E3Z
M8 connector
9.75
Note: The lens for the E3Z-D@1/D@6/L@@ is red. The lens for the E3Z-D@2/D@7 is black.
16
E3Z
32.2 32.2 10
15.5 15.5
Reflectors
Refer to E39-L/F39-L/E39-S/E39-R for details.
Mounting Brackets
17
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.