Product Overview
Huawei CloudEngine 8800 series switches are 100G Ethernet switches designed for data centers and high-end campus
networks. The switches provide high-performance, high-density 100GE/40GE/25GE/10GE ports, and low latency. Using the
Huawei VRP8 software platform, CloudEngine 8800 series switches provide extensive data center service features and high
stacking capability. In addition, the airflow direction (front-to-back or back-to-front) can be changed. CloudEngine 8800 series
switches can work with CloudEngine 16800/CloudEngine 12800/CloudEngine 8800/CloudEngine 6800/CloudEngine 5800
switches to build an elastic, virtualized, high-quality fabric that meets the requirements of cloud-computing data centers.
CloudEngine 8800 series switches can function as core or aggregation switches on data center networks to help enterprises
and carriers build a scalable data center network platform in the cloud computing era. They can also be used as aggregation or
core switches for enterprise campus networks.
Product Appearance
CloudEngine 8850-32CQ-EI provides 32*100GE QSFP28 ports and 2*10GE SFP+ ports.
CloudEngine 8861-4C-EI supports four flexible cards of half the standard width.
The CloudEngine 8800 series switches support the following models of cards.
A stack system of 16 member switches (CloudEngine 8850-64CQ-EI/CloudEngine 8850-32CQ-EI) that provide high
density server access in a data center.
Multiple switches in a stack system are virtualized into one logical device, making it possible to build a scalable, easy-to-
manage data center network platform.
A stack system separates the control plane from the data plane. This eliminates the risk of single points of failure and
greatly improves system reliability.
Long-distance stacking
The CloudEngine 8800 series switches can use service ports as stack ports. A stack system can be established with
switches in the same rack or different racks, and even over long distances.
Service and stack bandwidths can be allocated based on the network's scale so that network resources can be used more
efficiently.
The CloudEngine 8800 series switches use a front-to-back/back-to-front airflow design that isolates cold air channels from
hot air channels. This design meets heat dissipation requirements in data center equipment rooms.
Air can flow from front to back or back to front depending on the fans and power modules that are used.
Redundant power modules and fans can be configured to ensure service continuity.
The CloudEngine 8800 series switches have energy-saving chips and can measure system power consumption in real
time. Fan speed can be adjusted dynamically based on system consumption. These energy-saving technologies reduce O&M
costs and contribute to a greener data center.
Port indicators clearly show the port status and port rate. The 40GE port indicators can show the states of all ports derived
from the 40GE ports.
State and stack indicators on both the front and rear panels enable users to maintain the switch from either side.
The CloudEngine 8800 series switches support remote positioning. Operators can turn on remote positioning indicators on
the switches they want to maintain, so that they can find switches easily in an equipment room full of devices.
Simple maintenance
The management port, fans, and power modules are on the front panel, which facilitates device maintenance.
Data ports are located at the rear, facing servers. This simplifies cabling.
Product Specifications
Note: This content is applicable only to regions outside mainland China. Huawei reserves the right to interpret this content.
M-LAG
BGP-EVPN
Data center VXLAN mapping, implementing interconnection between multiple DCI networks at Layer 2
interconnect
Network FCoE
convergence
DCBX, PFC, ETS
Programmability OPS
OpenFlow
sFlow
Default VLAN
QinQ
MUX VLAN
GVRP
MAC address table Dynamic learning and aging of MAC address entries
IP routing IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and Raw IP6
Multicast Multicast routing protocols such as IGMP, PIM-SM, PIM-DM, MSDP, and MBGP
IGMP snooping
IGMP proxy
Multicast VLAN
Multicast VXLAN
ERPS (G.8032)
QoS Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p
information
Queue scheduling algorithms, including PQ, WRR, DRR, PQ+WRR, and PQ+DRR
Traffic shaping
Telemetry
AI Fabric VIQ, Dynamic ECN, Fast CNP, Dynamic load balancing (DLB), RoCE flow visibility
(Supported by CloudEngine 8850-64CQ-EI and CloudEngine 8861)
Hot patches
Defense against DoS address attacks, ARP storms, and ICMP attacks
Note: This specification may vary between different scenarios. Please contact Huawei for details.
Hardware Specifications
Item CloudEngine CloudEngine CloudEngine
8850-32CQ-EI 8850-64CQ-EI 8861-4C-EI
Card NA NA CE88-D24S2CQ
Specification CE88-D24T2CQ
CE88-D16Q
CE88-D8CQ
CE88-24S2CQ-U
USB port 1
Number of cores 8 8 4
Power Supply Power modules AC: 600W AC: 1200W AC: 1200W
System DC: 600W -48V HDC: 1200W 380V HDC: 1200W 380V
DC: 1200W -48V DC: 1200W -48V
Rated voltage AC: 100V to 240V AC: 100V to 240V AC: 100V to 240V
range(V) DC: -48V to -60V DC 380V HVDC: DC 380V HVDC: 240V
240V to 380V to 380V
DC: -48V to -60V DC: -48V to -60V
Maximum voltage AC: 90V to 290V AC: 90V to 290V AC: 90V to 290V
range(V) DC: -38.4V to -72V 240V HVDC: 188V to 240V HVDC: 188V to
290V 290V
380V HVDC: 188V to 380V HVDC: 188V to
400V 400V
DC: -38.4V to -72V DC: -38.4V to -72V
Typical power 219W (100% traffic load, 375W (100% traffic Test condition 1: 100%
copper cable, normal load, copper cable, traffic load, passive
temperature, dual power normal temperature, copper cables on
modules) dual power modules) optical ports, normal
314W (100% traffic load, 568W (100% traffic temperature, dual
short-distance optical load, short-distance power modules:
modules, normal optical modules, four CE88-D24S2CQ
temperature, dual power normal temperature, cards: 437W
modules) dual power modules) four CE88-D24T2CQ
cards: 532W
four CE88-D16Q
cards: 383W
four CE88-D8CQ
cards: 398W
four CE88-24S2CQ-U
cards: 525W
Test condition 2: 100%
traffic load, short-
distance optical
modules on optical
ports, normal
Sound power at 27°C Front-to-back airflow: < 65 Front-to-back airflow: Front-to-back airflow:
(dBA) Back-to-front airflow: < 64 < 73 <65
Sound power at 40°C Front-to-back airflow: < 88 Front-to-back airflow: Front-to-back airflow:
(dBA) Back-to-front airflow: < 86 < 92 < 88
Back-to-front airflow: Back-to-front airflow: <
< 94 91
Note: For detailed information of CloudEngine 8800 Platform hardware information, visit
https://support.huawei.com/enterprise/en/doc/EDOC1000019246?idPath=7919710%7C21782165%7C21782239%7C22318540
%7C7597815
Safety EN 60950-1
EN 60825-1
EN 60825-2
UL 60950-1
CSA-C22.2 No. 60950-1
IEC 60950-1
AS/NZS 60950-1
GB4943
Note
Supported MIBs
For details about the MIB information, visit
https://support.huawei.com/hedex/hdx.do?docid=EDOC1100101219&lang=en&idPath=24030814%7C21782165%7C21782239
%7C22318540%7C7597815.
Ordering Information
Mainframe
CE8850-EI-B-B0A CE8850-32CQ-EI Switch (32-Port 100GE QSFP28, 2-Port 10GE SFP+,2*AC Power
Module,2*FAN Box, Port-side Intake)
CE8850-32CQ-EI CE8850-32CQ-EI Switch (32-Port 100GE QSFP28 Optical,2*FAN Box, Port-side Exhaust, Without
Power Module)
CE8850-EI-F-B0B CE8850-64CQ-EI Switch (64-Port 100GE QSFP28,2*AC Power Module,3*FAN Box, Port-side
Exhaust)
CE8850-EI-B-B0B CE8850-64CQ-EI Switch (64-Port 100GE QSFP28,2*AC Power Module,3*FAN Box, Port-side
Intake)
CE8850-64CQ-EI CE8850-64CQ-EI Switch (64-Port 100GE QSFP28, Without Fan and Power Module)
CE8861-4C-EI-F CE8861-4C-EI Mainframe (With 4 Subcard Slots,2*FAN Box, Port-side Exhaust, Without Power
Module)
CE8861-4C-EI-B CE8861-4C-EI Mainframe (With 4 Subcard Slots,2*FAN Box, Port-side Intake, Without Power
Module)
CE8861-4C-EI CE8861-4C-EI Mainframe (With 4 Subcard Slots, Without FAN Box, Without Power Module)
Subcard
CE88-D24T2CQ 24 Port 10GE Base-T and 2 Port 100GE QSFP28 Interface Card
CE88-D24S2CQ 24 Port 25GE SFP28 and 2 Port 100GE QSFP28 Interface Card
Fan box
Power
Software
CE88-LIC-AIF CloudEngine 8800 AI Fabric Function (Supported only by CE8850-64CQ-EI & CE8861)
such as VXLAN to establish a nonblocking large Layer 2 network, which allows large-scale VM migrations and flexible service
deployments.
Note: VXLAN can also be used on campus networks to support flexible service deployment in different service areas.
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or
part of the products, services and features described in this document may not be within the purchase scope or the usage
scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are
provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this
document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not
constitute a warranty of any kind, express or implied.