VERIFICATION
VERIFICATION
VERIFICATION
Design an integral nozzle in a cylindrical shell based on the vessel and nozzle data below. The parameter
used in this design procedure are shown in Figure E4.5.1
tr = PR = 1355(22.5) = 1.5890
SE-0.6p 20000(1.0)-0.6(1355)
c) STEP3- Calculte the Area of Reinfocement see Fig. UG-37.1 (with Reinforcing Element
per Fig UG-40(e-1)).
1) Area Required A:
A=dtrF+2tntrF(1-fr1)
A=2.25(1.5890)(1.0)+2(0.529)(1.5988)(1.0)(1-1.0) = 3.575
Note: The thickness of the reinforcing pad, tr , exceeds the outside vertical reinfocement
zone limit. Therefore, the reinforcement area in the pad is limited to within the zone.
A1 = d(E1t-Ftr)-2tn(E1t-Ftr)(1-fr1)
= 0.14526 0.0381
= 0.107
A41 = (leg)²fr3
= 0.4225
A42 = (leg)²fr4
= 0.140625
A43 = (leg)²fr2
= 0.140625
A5 = (Dp-d-2tn)te fr4
= 1.108