0% found this document useful (0 votes)
328 views3 pages

Master Protection Code - ANSI

The document lists ANSI device numbers and their corresponding relay or control device descriptions. There are over 100 listings ranging from master elements, time delay relays, checking relays, circuit breakers, temperature controls, overcurrent relays, differential relays, frequency relays, and more. The ANSI numbers provide a standardized identification system for relaying and control devices used in power system protection and control applications.

Uploaded by

brijal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
328 views3 pages

Master Protection Code - ANSI

The document lists ANSI device numbers and their corresponding relay or control device descriptions. There are over 100 listings ranging from master elements, time delay relays, checking relays, circuit breakers, temperature controls, overcurrent relays, differential relays, frequency relays, and more. The ANSI numbers provide a standardized identification system for relaying and control devices used in power system protection and control applications.

Uploaded by

brijal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

C&S PROTECTION & CONTROL LTD.

List of ANSI Numbers


• 1 - Master Element
• 2 - Time Delay Starting or Closing Relay
• 3 - Checking or Interlocking Relay
• 4 - Master Contactor
• 5 - Stopping Device
• 6 - Starting Circuit Breaker
• 7 - Anode Circuit Breaker
• 8 - Control Power Disconnecting Device
• 9 - Reversing Device
• 10 - Unit Sequence Switch
• 12 - Overspeed Device
• 13 - Synchronous-speed Device
• 14 - Underspeed Device
• 15 - Speed - or Frequency-Matching Device
• 20 - Elect. operated valve (solenoid valve)
• 21 - Distance Relay
• 21FL – Distance fault locator
• 23 - Temperature Control Device
• 24 – Overfluxing (V/Hz)
• 25 - Synchronizing or Synchronism-Check Device
• 26 - Apparatus Thermal Device
• 27 - Undervoltage Relay
• 28 – Flame detector
• 29 - Isolating Contactor
• 30 - Annunciator Relay
• 31 – Separate excitation device
• 32 - Directional Power Relay
• 33 – Position switch
• 34 – Master sequence device
• 36 - Polarity or Polarizing Voltage Devices
• 37 - Undercurrent or Underpower Relay
• 38 - Bearing Protective Device
• 39 - Mechanical Conduction Monitor
• 40 - Field Relay
• 41 - Field Circuit Breaker
• 42 - Running Circuit Breaker
• 43 - Manual Transfer or Selector Device
• 46 - Reverse-phase or Phase-Balance Relay
• 47 - Phase-Sequence Voltage Relay
• 48 - Incomplete-Sequence Relay
• 49 - Machine or Transformer Thermal Relay
C&S PROTECTION & CONTROL LTD.
• 50 - Instantaneous Overcurrent
• 50V – Voltage dependent instantaneous overcurrent
• 50N – Instantaneous earth fault
• 51 - AC Time Overcurrent Relay
• 51V – Voltage dependent time delayed overcurrent
• 51N – Time delayed earth fault
• 51G – Sensitive earthfault (with CBCT arrangement)
• 52 - AC Circuit Breaker
• 53 - Exciter or DC Generator Relay
• 54 - High-Speed DC Circuit Breaker
• 55 - Power Factor Relay
• 56 - Field Application Relay
• 57 – Short ckt or grounding device
• 58 – Rectification failure
• 59 - Overvoltage Relay
• 59N – Neutral overvoltage
• 60 - Voltage or Current Balance Relay
• 60FL – VT fault locator
• 61 - Machine Split Phase Current Balance
• 62 - Time-Delay Stopping or Opening Relay
• 63 - Pressure Switch
• 64 - Ground Detector Relay
• 64S – Stator ground detector
• 64N – Rotor ground detector
• 64R – Restricted earth fault
• 65 - Governor
• 66 - Starts per Hour
• 67 - AC Directional Overcurrent Relay
• 67N – Directional earth fault
• 68 - Blocking Relay
• 69 - Permissive Control Device
• 70 - Rheostate
• 71 - Level Switch
• 72 - DC Circuit Breaker
• 74 - Alarm Relay
• 74TC – Trip circuit supervision
• 74CC – Close circuit supervision
• 75 - Position Changing Mechanism
• 76 - DC Overcurrent Relay
• 77 – Tele metering device
• 78 - Phase-Angle Measuring or Out-of-Step Protective Relay
• 79 - AC-Reclosing Relay
• 81O – Over Frequency Relay
C&S PROTECTION & CONTROL LTD.
• 81U – Under frequency relay
• 81R – Rate of change of frequency (df/dt)
• 83 - Automatic Selective Control or Transfer Relay
• 84 - Operating Mechanism
• 85 - Carrier or Pilot-Wire Receiver Relay
• 86 - Lockout Relay
• 87 - Differential Protective Relay
• 87B – Bus Differential Relay
• 87G – Generator Differential Relay
• 87H – High Impedance Differential Relay
• 87L – Line Differential Relay
• 87T – Transformer Differential Relay
• 87U – Unit Differential Relay
• 89 - Line Switch
• 90 - Regulating Device
• 91 - Voltage Directional Relay
• 92 - Voltage and Power Directional Relay
• 94 - Tripping or Trip-Free Relay
• 95 - Reluctance Torque Synchrocheck
• 96 - Autoloading Relay