This document provides specifications for Zelio Time modular timing relays with relay outputs that are 17.5mm wide. It details their timing characteristics such as selectable ranges from 0.1 seconds to 100 hours, accuracy of ±0.5%, and minimum pulse duration of 30ms. Environmental specifications include an operating temperature range of -20°C to +60°C and IP40 protection. Electrical characteristics include AC power supply voltages of 12-240V, 1 C/O output contact, and breaking capacity up to 2300VA/80W.

Uploaded by

FERBRAM g
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
353 views4 pages

RE11RMMU

This document provides specifications for Zelio Time modular timing relays with relay outputs that are 17.5mm wide. It details their timing characteristics such as selectable ranges from 0.1 seconds to 100 hours, accuracy of ±0.5%, and minimum pulse duration of 30ms. Environmental specifications include an operating temperature range of -20°C to +60°C and IP40 protection. Electrical characteristics include AC power supply voltages of 12-240V, 1 C/O output contact, and breaking capacity up to 2300VA/80W.

Uploaded by

FERBRAM g
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Characteristics 2

Zelio Time -
modular timing relays 2

Relays with relay output,


width 17.5 mm

Timing characteristics
Relay type RE11 R3233 RE11 RME MU
Selectable timing ranges s 0.1…1 0.1…1
by selector switch on front panel 1…10 1…10
min 0.1…1 0.1…1
1…10 1…10
h 0.1…1 0.1…1
1…10 1…10
10…100 –
2 Repeat accuracy
(with constant parameters)
Conforming to IEC 61812-1 ± 0.5 %

Drift Temperature ± 0.05 % / °C


Voltage ± 0.2 % / V
Setting accuracy Conforming to IEC 61812-1 ± 10 % at 25 °C
at full scale
Minimum duration Typical ms 30
of control pulse Typical with load in parallel ms 100
Maximum reset time Typical ms 100
by de-energisation
Immunity to microbreaks Typical ms > 10

Supply characteristics
Relay type RE11 R3233 RE11 R3 JU
2 13 21
13 2
Supply voltage V / 12…240 / 12 V
24/ 24…240 depending on version
Frequency Hz 50/60
Operating range 85…110 % of Un 90…120 % of Un
On-load factor 100 %
Maximum power Depending 2/1 12 V VA/W – 0.4
consumption on model 1 24 V W 0.6 –
1 240 V W 1.5 –
2 240 V VA 32 –

Output characteristics
Relay type RE11 R3233 RE11 RME MU
Output type Relay, 1 C/O contact, AgNi (cadmium-free)
Breaking capacity 23 2000 VA,13 80 W 23 13
1250 VA, 50 W

Maximum breaking current A 238, 138 235, 135


Minimum breaking current mA 10 /1 10 V

Maximum switching voltage V 2/13250 (except RE11 RMX MU: 2 250 and 1 150 )
Electrical life 105 operations 8 A 250 V resistive 105 operations 5 A 250 V resistive

Mechanical life 5 x 106 operations


Dielectric strength Conforming to IEC 61812-1 kV 2.5/1min/1 mA/50 Hz
Impulse voltage Conforming to IEC 60664-1, kV 5, wave: 1.2/50 µs
IEC 61812-1
Display characteristics
State indication by 1 LED Green Operating status indication
Pulsing: relay energised, no timing in progress (except functions Di-D and Li-L)
Flashing: timing in progress
On steady: relay energised, no timing in progress

Input characteristics
Input type Volt-free contact (no potential)
Control possible by 3-wire sensor with PNP output, maximum residual voltage: 0.4 V
whatever the supply voltage of the timer

References : Dimensions : Schemes :


pages 2/23 and 2/24 pages 2/24 and 2/26 pages 2/25 and 2/27

2/22
Characteristics (continued) 2
Zelio Time -
modular timing relays 2

Relays with relay output,


width 17.5 mm

General characteristics
4
Conforming to standards IEC 61812-1, EN 50081-1/2, EN 50082-1/2, LV directives (73/23/EEC + 93/68/EEC
( marking) + EMC directive (89/336/EEC + IEC 60669-2-3)

Approvals cULus, CSA,


GL except RE11 RMX MU and RE11 RME MU
Ambient air temperature Storage °C - 30…+ 60
around the device Operation °C - 20…+ 60

Creepage distance Conforming to IEC 60664-1 kV 4 kV/3


and clearance
Degree of protection Terminal block IP 20
2
conforming to IEC 60529 Housing IP 40
Front panel IP 50
Vibration resistance Conforming to IEC 60068-2-6 f = 10…55 Hz
A = 0.35 mm

Relative humidity Conforming to IEC 60068-2-3 93 %


without condensation
Electromagnetic compatibility Immunity to Level III (Air 8 kV/Contact 6 kV)
electrostatic discharge,
conforming to IEC 61000-4-2
Immunity to Level III (10 V/m: 80 MHz…1 GHz)
electromagnetic fields,
conforming to ENV 50140/204
(IEC 61000-4-3)
Immunity to Level III (direct 2 kV / capacitive connecting clip 1 kV)
fast transients in bursts,
conforming to IEC 61000-4-4
Immunity to Level III (common mode 2 kV / differential mode 1 kV)
surges on the power supplies,
conforming to IEC 61000-4-5
Immunity to radio frequency Level III (10 V rms: 0.15…80 MHz)
interference in common mode,
conforming to ENV 50141
(IEC 61000-4-6)
Immunity to 30 % / 10 ms
voltage dips and breaks, 60 % / 100 ms
conforming to IEC 61000-4-11
95 % / 5 s
Radiated and mains Class B
conducted disturbance,
conforming to EN 55022
(EN 55011 Group 1)

Fixing Symmetrical mounting rail mm 35


(EN 50022)
Clamping capacity Without cable end mm2 2 x 2.5 and 1 x 4
With cable end mm2 2 x 1.5

Spring terminals, 2 terminals Flexible cable mm2 1.5


per connection point Solid cable mm2 2.5

Housing material Self-extinguishing

References : Dimensions : Schemes :


pages 2/23 and 2/24 pages 2/24 and 2/26 pages 2/25 and 2/27

2/23
Functions, Zelio Time -
references, modular timing relays 2

dimensions, Relays with relay output,


width 17.5 mm
scheme 2

Output 1 C/O contact Function diagrams


1 Multifunction Function A Function At Function B
1 Multi-range (6 or 7 selectable ranges) Delay on energisation Delay on energisation Timing on impulse, one shot
1 Multivoltage with memory
1 1 relay output: 5 or 8 A U U
1 Screw or spring terminals U

1 State indication by 1 LED C C


R
1 Option of supplying a load in parallel T
1 3-wire sensor control option R R

2 T = t1 + t2 + …
t1 t2 T T

Function C Function H Function Ht


Timing after opening Timing on energisation Timing on energisation
of control contact with memory
U U U

C R C
T
R R
T T t1 t2
T = t1 + t2 + …

Function D Function Di Function Ac


Symmetrical flashing, start Symmetrical flashing, start Timing after closing and
with output in rest position with output in operating opening of control contact
position

U U U

R R C
T T T T T T T T T T T
R
T T

References
521931

521931

Functions Multifunction Multifunction


A - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw
Timing ranges 6 or 7 ranges 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
Voltages 2 13
/ 12 V – –
13 2324 V / 24…240 V RE11 RM MU –
2 13
/ 12…240 V – RE11 RM MW
Nominal output current 8A 8A
Connection Screw terminals 5 5
Spring terminals – –
Weight (kg) 0.060 0.060
Dimensions and connection scheme
Dimensions
RE11 RM3 MU, RE11 RM MW, RE11 RM JU RE11 RM MWS
72 72
5,5 17,9 5,5 17,9
81

81

Characteristics : Schemes :
pages 2/22 and 2/23 page 2/25

2/26
2
2

Function Bw Function Ad Function Ah Function N Function O


Pulse output (width Timing on closing Flashing single cycle by "Safe-guard" "Delayed safe-guard"
adjustable) of control contact operation of control contact
U U U U U

C C C C C

R
R R R R T T t<T T
T T T T T T T T T
2
Function P Function Pt Function T Function Tt Function W
Delayed fixed-length pulse Impulse counter (on-delay) Bistable relay Timed impulse relay On-delay after opening
of control contact
U U U U U

R G C C C
T P
R R R R
t1 t2 P T t<T T

T = t1 + t2 + …
P = 500 ms P = 500 ms
521932

521931

521931

521933

Multifunction Multifunction Multifunction Multifunction


A - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di - Ac - Bw A - At - B - C - H - Ht - D - Di Ad - Ah - N - O - P - Pt - T - Tt - W
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
– RE11 RM JU – –
– – RE11 RME MU RE11 RMX MU
RE11 RM MWS – – –
8A 8A 5A 8A
– 5 5 5
5 – – –
0.060 0.060 0.060 0.060

Connection scheme

+
Y1
A1

(1)
A2 Y1

16
18 15 (1) Contact Y1 :
R - Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.
- Partial stop for functions At, Ht and Pt.
- Function D if Di selected.
- Not used for functions A, H and P.

Characteristics : Dimensions :
pages 2/22 and 2/23 page 2/24

2/27