Service Manual
Service Manual
Service Manual
SJ-D64M/P65M
SJ-D69M/P70M
SERVICE MANUAL
S5311SE68CPUT
Plasmacluster
REFRIGERATOR-FREEZER
MODELS
SJ-D59M-GL/GY/SLG
SJ-P60M-GL/GY/SLG
SJ-D64M-GL/GY/SLG
SJ-P65M-GL/GY/SLG
SJ-D69M-GL/GY/SLG
SJ-P70M-GL/GY/SLG
In the interests of user-safety (Required by safety regulations in some
SJ-P60M SJ-D59M countries) the set should be restored to its original condition and only
SJ-P65M SJ-D64M
SJ-P70M SJ-D69M parts identical to those specified should be used.
DESTINATION ......................... T
Refrigerant; HFC-134a
Refer to "HFC-134a COOLING UNIT" Service Manual for handling this refrigerant.
TABLE OF CONTENTS
page
CAUTIONS AND INFORMATIONS .................................................................................................................. 2
SPECIFICATIONS ............................................................................................................................................ 3
DESIGNATION OF VARIOUS PARTS ............................................................................................................. 4
LIST OF ELECTRICAL PARTS ........................................................................................................................ 5
DIMENSIONS ................................................................................................................................................... 5
WIRING DIAGRAM ........................................................................................................................................... 7
FUNCTIONS ................................................................................................................................................... 11
ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS ............................................................. 15
COOLING UNIT .............................................................................................................................................. 23
REPLACEMENT PARTS LIST ....................................................................................................................... 25
SHARP CORPORATION
1
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
2
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
SPECIFICATIONS
Items SJ-D59M SJ-P60M SJ-D64M SJ-P65M SJ-D69M SJ-P70M
Type 2-Door 2-Door 2-Door
Outer dimensions Height 1620mm(63.8") 1720mm(67.7") 1820mm(71.6")
Width 760mm(29.9") 760mm(29.9") 760mm(29.9")
Depth 740mm(29.1") 740mm(29.1") 740mm(29.1")
Rated storage volume [ ISO ] 492 liter (17.7 cu.ft) 535 liter (18.9 cu.ft) 577 liter (20.4 cu.ft)
(Rated volume) F: 151 liter (5.3 cu.ft) F: 151 liter (5.3 cu.ft) F: 151 liter (5.3 cu.ft)
R: 341 liter(12.1 cu.ft) R: 384 liter(13.6 cu.ft) R: 426 liter(15.1 cu.ft)
Gross volume [ ISO ] 526 liter (18.6 cu.ft) 566 liter (20.0 cu.ft) 606 liter (21.4 cu.ft)
F: 177 liter (6.3 cu.ft) F: 177 liter (6.3 cu.ft) F: 177 liter (6.3 cu.ft)
R: 349 liter(12.3 cu.ft) R: 389 liter(13.7 cu.ft) R: 429 liter(15.1 cu.ft)
Thai standard volume [ TIS ] 488 liter (17.24 cu.ft) 528 liter (18.66 cu.ft) 563 liter (19.89 cu.ft)
F: 157.5 liter(5.57 cu.ft) F: 157.5 liter(5.57 cu.ft) F: 157.5 liter(5.57 cu.ft)
R: 330.5 liter(11.67 cu.ft) R: 370.5 liter(13.09 cu.ft) R: 405.5 liter(14.32 cu.ft)
Defrosting System Heater system
Start Automatic
Finish Automatic
Temperature control Automatic (Adjustable)
No-frost freezer Yes
Interior lamp 2
Caster 4
Evaporating pan 1
Refrigerator R glass shelf ass'y 2 3
Compartment V glass shelf ass'y 1
Vegetable case 1
V parting plate 1
R door pocket 1 2
Egg tray 2
Bottle pocket 2
Utility case pocket 1
Fresh case 1
Tube stand 2
Freezer Freezer shelf ass'y 1
Compartment Ice cube maker Twin ice cube maker
Ice storage box 1
F door pocket 2
Deodorizing unit 2 (Honeycomb type)
Plasmacluster No Yes No Yes No Yes
RATING
Items SJ-D59M SJ-P60M SJ-D64M SJ-P65M SJ-D69M SJ-P70M
Rated voltage (V~) 220-240
Rated frequency (Hz) 50
Climate class T
Rated current (A) 1.4-1.5
Rated input of heating systems (W) 144-170
Refrigerant (Charging quantity) [Non-flammable] HFC-134a(120g) HFC-134a(125g) HFC-134a(130g)
Insulation blowing gas [Flammable] Cyclo pentane (HC)
Net Weight (kg) 83 85 90
PLUG TYPE
Plug cord 2 pin Plug type
Destination mark T
COLOR
Items -GL -GY -SLG
Outside color Gold Gray Silver
Inside color White
3
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
Hot pipe
Ionizer (only for SJ-P60M,P65M,P70M)
Refrigerator Timer,R-fan thermo ass'y
compartment Refrigerator fan
Damper thermostat
Refrigerator temp. control knob
Drain pipe
Vegetable case
Main P. W. B (only for SJ-P60M,P65M,P70M)
Ventilating grille Compressor
Starting relay, Overload relay(Protector)
Evaporating pan
Adjustable leg ass'y Sub condenser
Caster
4
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
DIMENSIONS
OUTER DIMENSIONS AND CLEARANCE
more than
60
more than more than
1
760 more than
740 60 60
90 760
553
9.5
1420
1480
A
135
B
12
520
60.5
72.5
1340
( Unit : mm)
SJ-D59M,P60M SJ-D64M,P65M SJ-D69M,P70M
A 1620 1720 1820
B 979 1079 1179
1 Include the panel/badge. Not include the handle.
Fig. E-1
5
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
INNER DIMENSIONS
587 90
174
294
603
450
264
587 90
630
110
125
615
177 355 285
110
615
b
615 310
a
607 133 310
615
d
615 335
607
133
242
600
227
SJ-D59M,P60M SJ-D64M,P65M
a 466 566
b 180 180
c 135 185
d 121 171 ( Unit : mm)
The dimensions between shelves can be changed
by setting the shelves on the other rails.
587
174
90
603 294
450
587
264
90
630
615 110
125
615 310
615 110
135
615 310
666
135
615 335
607
133
242
600
227
( Unit : mm)
The dimensions between shelves can be changed
by setting the shelves on the other rails.
6
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set.
G : GRAY
BR : BROWN (Live)
OR : ORANGE
Y : YELLOW
R : RED CONNECTED IN TERMINAL BOX
P : PINK
B : BLUE (Neutral) CONNECTOR
BK : BLACK
SB : SKY-BLUE
G-Y : GREEN-YELLOW (Earth)
W : WHITE
DEF. TIMER
(Br)
R- R-FM THERMOSTAT TM (G)
LAMP HEATER R
MAIN F
2PIN
PWB F- L FM
PLUG/ LAMP FM
CORD
L THERMO.
FUSE
PC
R-FAN
THERMO DEFROST HEATER
PROTECTOR
DOOR
PWB DEFROST THERMO
DOOR SWITCH
STARTING RELAY C
M
(B)
A
COMPRESSOR
PC : PLASMACLUSTER UNIT (IONIZER-K)
DEF. TIMER
(Br)
R- R-FM THERMOSTAT TM (G)
LAMP HEATER R
2PIN L F
F- FM
PLUG/ LAMP FM
CORD
L THERMO.
FUSE
R-FAN
THERMO DEFROST HEATER
PROTECTOR
DEFROST THERMO
DOOR SWITCH
STARTING RELAY C
M
(B)
A
COMPRESSOR
Figure W-2. Wiring Diagram (SJ-D59M,D64M,D69M)
7
F LAMP BOX ASS'Y
SJ-D69M/P70M
SJ-D64M/P65M
SJ-D59M/P60M
(R-FAN 1 1 SB-2
THERMO. HEATER) BR-3
2 2
OR-3
3 3
R FAN THERMO. OR-2
4 4
8
R LAMP BOX ASS'Y
1 1 GY-3
R-FAN MOTOR FM (OR-4) CLUSTER HARNESS PU
2 2
SB-3
L
3 3
R-LAMP (15W) BR-5
4 4
LAMP SOCKET
1 TERMINAL BOX
ORANGE BROWN 1 BLUE 1 GRAY 1 2
3
MAIN
G : GRAY SKY-BLUE OR-4 PWB
1
BR : BROWN (Live) BLUE 2 GRAY 2 BR-6
BROWN 2 2
BL-3
OR : ORANGE 3 1
GY-3
Y : YELLOW 4 2
PWB HARNESS
R : RED
P : PINK PROTECTOR
B : BLUE (Neutral) COMPRESSOR
BK : BLACK C
SB : SKY-BLUE M
A
G-Y : GREEN-YELLOW (Earth)
SOURCE CORD STARTING RELAY
W : WHITE
TERMINAL BLOCK
E. V. COVER ASS'Y
LEAD EV-COVER ASS'Y GY-1
1 1
FAN MOTOR FM OR-1
2 2
R-1
F-THERMOSTAT 3 3
BR-2
4 4
Y-1
DEF. THERMO. ASS'Y 5 5
BL-1
6 6
BK-1
FUSE ASS'Y 7 7
W-1
8 8
9 9
(W-1)
1 1
DEF. HEATER ASS'Y Y-2
2 2
DOOR SWITCH
OR-2
3 (PUSH CLOSE) 3
BL-2
1 (NEUTRAL) 1
SB-1
4 (PUSH OPEN) 4
(W-2)
2 (PUSH OPEN) 2
(R-FAN SB-2
1 1
THERMO. HEATER) BR-3
2 2
OR-3
3 3
R FAN THERMO. OR-4
4 4
9
R LAMP BOX ASS'Y
1 GY-3
1
R-FAN MOTOR FM (OR-4)
2 2
SB-3
3 3
R-LAMP (15W) L BR-5
4 4
LAMP SOCKET
TERMINAL BOX
ORANGE BROWN 1 BLUE 1 GRAY 1
SKY-BLUE
BROWN 2 BLUE 2
G : GRAY
BR : BROWN (Live)
OR : ORANGE
Y : YELLOW
PROTECTOR
R : RED COMPRESSOR
P : PINK
C
B : BLUE (Neutral) M
BK : BLACK A
SB : SKY-BLUE SOURCE CORD STARTING RELAY
G-Y : GREEN-YELLOW (Earth) TERMINAL BLOCK
W : WHITE
HS
D1
3 IN4007E R1 R2 R3
PC1 R4
7 10K R7
PC123 1K
VRS2
F-FM R5 C7 C12 C8 C20
2.2K 0.1μ 0.1μ 0.1μ 100μ
D2 R8
1 2A ISS270A 10V
4 10K
VAREF VDD
R40(AINO) K03
R41(AIN1) K02
R42(AIN2) K01
R12 4.7K R20 R43(AIN3) K00 PST993E
(PANEL PWB)
2.2K C11 RS1 R71(WT0) HOLD 1M R6 IC3
CN4 CN3 Q7 R80(INT2) RESET
5 0.1μ KRA101M 3 1
R81(T2) XOU 2
R82(INT1) XIN C5 C4
SW R11 1μ C6 0.1μ
1 1 RS2 P10 TEST 0.1μ
1K 50V
R10 R9 RS3 P11 R92
12V 2.2K 1K P12 R91
ZD1 Q5 P13 R90
R21 KRA101M VSS P20
(1/2W) CF1 CST4.00MGW
10
3 3 Q6 TMP47C241N
680 6
KRA101M IC4
Q4
LED1 KRC101M
7 220 240V RS1,2,3=43K(1/2W), RS3=OPEN, VRS1,2=560V
2 2 INPUT VOLTAGE
120V RS1,2,3=18K(1/2W), RS3=10K(1/8W), VRS1,2=270V
110 120V RS1,2,3=18K(1/2W), RS3=SHORT, VRS1,2=270V
12V
R13
Q3 4.7K
CN2 8 KTA1046
R15
1 4.7K
R16 C13 Q1 [ NOTE ]
PC 10K 0.1μ KRA101M
2 9
Q2 1. Resistance which is not specified : 5% 1/8W
KRC101M 2. Rated voltage of the condenser which is not specified : 25V
PC :
PLASMACLUSTER UNIT
(IONIZER-K)
R18 D7 R14
10K ISS270A 1K
R17 (A/D)
(1/2W) C15 C10 C9
1.8 100μ 1μ 0.1μ
10V 50V
(MAIN PWB)
FUNCTIONS
1. ADJUSTABLE TEMPERATURE CONTROL
(1) Temperature control of freezer
Thermostat (senses freezer temperature) operates on ON/OFF switchover to control the compressor and
cool air circulating fan (F-fan motor) , and allows the freezer temperature to keep at a suitable temperature.
However adjust the freezer temp. control knob as follows depending upon the storing condition of foods.
MED
4 5 KNOB PURPOSE
3 6
2 SETTING
1 7
MIN MAX MAX(Coldest) For making ice rapidly or fast freezing.
Coldest
When restocking with fresh food.
MED For normal freezing.
For storing frozen food for a short period (up to one month).
FREEZER TEMP. CONTROL
Figure F-1. MIN When frozen food or ice cream is not stored.
When the temperature of the refrigerator is higher, R-fan thermo. senses the temperature and the
refrigerator is cooled efficiently by running of R-fan motor.
R-fan thermo. heater energizes when the door is opened intend to promote to running of R-fan motor.
NOTE: The refrigerator temperature is affected also by the freezer temperature. If the freezer temp. control
knob is set at the position "MAX", the temperature tends to be lower than the following values, and
if set at near the position "MIN", temperature tends to be higher.
If the refrigerator is operated for a long time with the freezer temperature control sets the "MAX"
position, foods stored in the refrigerator compartment may also freeze.
When refrigerator temperature control sets to the "MAX", some foods stored may freeze.
In this case adjust control set back to the "MED" position.
When refrigerator temperature control sets to the "MAX", some foods stored in Fresh case may
also become frozen.
SETTING OF SETTING OF
FREEZER TEMP. MAX MED MIN REFRIGERATOR TEMP. MAX MED MIN
CONTROL KNOB (Coldest) CONTROL KNOB (Coldest)
Freezer Approx. Approx. Approx. Refrigerator Approx. Approx. Approx.
temperature -21 C -18 C -15 C temperature 0C 3C 6C
The values shown above refer to the measurement carried out center area and 1/3 of overall height from the bottom
at each of the refrigerator and the freezer after machine has been operated at an ambient temperature of 30˚C with no
food stored and the door closed until the temperature is stabilized.
The values vary depending upon frequency of opening and closing the door, ambient temperature, amount of stored
foods and manner of storing foods.
11
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
2. DEFROSTING
(1) No defrosting operation is necessary (2) Where is melted frost brought
No defrosting operation is necessary. 1. Melted frost is brought into the evaporating
As this machine is so designed that a built-in pan at the bottom of the set and is evaporated
evaporator cools air and a fan circulates cooled here by the heat of sub condenser.
air, neither the freezer nor the refrigerator is 2. Be sure that the evaporating pan is inserted
frosted, though the evaporator is frosted. correctly and is level.
The frosted evaporator is defrosted automatically
due to the function of defrosting timer and heater,
requiring no defrosting operation.
(3) The following circuit diagrams in the table show automatic defrosting function of the refrigerator with
timer and defrost thermostat.
Compressor
Thermo. fuse Timer motor
SOURCE
Defrost
thermostat (ON)
Figure F-3.
2. Defrosting Defrost thermostat ON Compressor stops The timer contact is changed to start
(Time 20 to 30 min.) Timer motor stops defrosting, the timer motor stops, and
Thermostat Timer contact power is supplied to the defrost heater.
It takes about 20 to 30 min. to defrost.
Compressor
Timer motor
Defrost heater TM COMP little time. When much frosted, the def-
rosting takes much time.
Defrost
thermostat (ON)
Figure F-4 .
3. Drain Defrost thermostat OFF Compressor stops When the defrost thermostat becomes
(Time approx. 5 min.) Timer motor running OFF, the timer motor starts running.
Thermostat Timer contact During the operation time (delay time
of defrost time) defrosted water is
Compressor
Timer motor
Defrost
thermostat (OFF)
Figure F-5.
4. Restart Defrost thermostat OFF Compressor running Timer contact is changed to cooling
(Time approx. 5 min.) Timer motor stops operation and the compressor starts
Thermostat Timer contact running and the timer motor stops.
Defrost thermostat contact becomes ON
Compressor
Timer motor
Defrost
thermostat (OFF)
Figure F-6.
12
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(4) As a reference to determine the causes of trouble, malfunction and phenomena are described below.
Refer to the following when repairing.
1. Disconnection of defrost heater
As off-cycle defrosting is performed, the defrosting time is extremely prolonged. Each time defrosting is
started, the freezer temperature rises and a portion of ice and stored foods are melted.
2. Melted thermo. fuse or opened-circuit due to the defect of defrost thermostat.
When the above mentioned trouble occurs in cooling operation, the timer motor does not run, defrosting
will not take place, and consequently freezing is caused. In the above mentioned condition, when the timer
shaft is turned by hand to defrost, the timer motor runs during the operation time. However, the motor stops
from the time when the contact is changed, and freezing causes.
NOTE:
As the thermo. fuse assembly is intended to prevent dangers, do not use it under shorted condition even
for a short period.
3. DEW PREVENTION
The hot pipe, namely D.P.-condenser, is arranged around the flange part of
cabinet and the C-partition plate, preventing dew from being generated on
the cabinet.
NOTE:
D.P.-condenser pipe may be felt hot if touched by hand while the
compressor is in operation.
If you are asked about this, please explain that the hot pipe serve to Hot pipe
prevent the dew generation.
Figure F-7
4. INSPECTION OF INITIAL STARTING
(1) Inspection of cooling unit
1. Set the temperature control knob to "MAX" and check that the compressor starts to operate.
2. Depress the door switch to run the fan and check that cool air is blown out of the cold air outlet of the
freezer and the refrigerator.
3. When the compressor does not work, check that the timer is not set to "defrost" position.
4 It takes about an hour and a half or two hours to put food in the refrigerator after starting operation.
NOTE:
After return the temperature control knob to "MED" position.
When the refrigerator is operated initially after installed, the compressor may vibrate excessively for 1 to 2
min. However, vibration becomes normal if it is continuously operated.
13
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
follows.
Button
(3) Plasmacluster Control.
1.Plasmacluster operation will be performed when the following conditions
gather.
1) Lamp : Under lighting
2) Compressor : Under operation
3) Door : Closed
4) Within "The Plasmacluster operation time".
2.If the sum total of Plasmacluster operation time will reach at the set time ("The Plasmacluster operation Time") ,
Plasmacluster operation will stop.
3.After an operation stop, the Plasmacluster will be not operated during the set time ("The Plasmacluster operation
compulsive stop time") .
Time chart A
Compressor
ON
Door
Plasmacluster
t1 t2 t3
Time chart B
Compressor
Door
Plasmacluster
t1 t2 t3
14
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING.
R air guider A
Defrost timer
Plasma harness
Plasma holder
RA sealer C
R fan thermo. ass'y
Fan cover
Figure A-1
Damper
thermostat
3 +1 mm
5 +1 mm
Stick thermo.
25 + 2 mm cap. sealer
NOTE
Less than 12 mm
Figure A-2
15
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(2) Sticking of sealers to R air guider A.
OVERLAP 15mm
RA sealer A OVERLAP 15mm
Dial sealer
[Bottom side]
RA sealer A RA sealer A
Figure A-3
2P 2P
Ionizer-K
Connecter should insert surely. Holder cover
2P
Plasma harness
2P
2P
B
R aire guider A
Plasma holder
Ionizer-K
Holder cover
3
2P
5
Plasma 25 5 15 5
5
10
harness
R aire guider A
B
SEC. B-B
Figure A-4
16
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(4) Fixing of Defrost timer, R fan thermo. ass'y cover to R-C box cover.
Defrost timer
Cut
10 + 5mm
G R fan thermo.
ass’y
Nylon band
Fan cover
SEC. G-G
Figure A-5
R-fan motor
Propeller fan 80
Fan clamp
Lamp 15W
Warning label
R lamp box
Figure A-6
17
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(1) Fixing of Lamp and Lamp socket.
(1)-1 Screw Lamp 15W into Lamp socket. (2)-4 Set Fan clamp to Propeller fan 80 and insert it
(1)-2 Fix Lamp socket on R lamp box by tapping to the shaft of R-fan motor.
screws.
Tapping screw
F
Lamp socket Fan clamp
ALUMINUM TAPE
Lamp 15W
Propeller fan 80
2.3 + 0.5mm
Figure A-7
Detail of F
(1)-3 Insert the terminal of Lamp socket to R-fan motor. Fan clamp
Slit of each Fan clamp and Propeller fan
DOUBLE CLAMPING WIRES
should not be at same position.
Figure A-8
Warning label
Figure A-9
18
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
Fuse ass’y
F-thermostat
E.V cover
sealer D
(2 pieces)
Figure A-12
Sticking start
Sticking start
Figure A-13
19
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(2)-1 Stick U-sealer handle to Fan motor holder A. Fan motor holder A
C
7 + 2mm
0 + 1mm
U-sealer handle
C
U-sealer handle
SEC. C-C
Figure A-14
Fan motor
Figure A-15
4 + 0.5mm
Shaft
Detail of D
Figure A-16
20
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
(3) Setting of Fan motor ass'y , Defrost thermo. ass'y and Fuse ass'y
E.V cover
sealer C
L-band C
E
Lead E.V-
cover ass’y Defrost
thermo. ass’y
Tapping E
more than more than Aluminum
3.5mm 3.5mm screw
tape Set metal side below
[FRONT SIDE] Aluminum
tape
10 + 5mm
E.V
cover ATTENTION
L-band C
Fuse
ass’y Turn up is lead wire Not come out of claw
Figure A-17
F-thermostat 4
1 2 3
(BROWN, inserted)
4 5 6 Fan motor 9
Defrost thermo. 5 7 8 9
(PINK) Fuse 8
(WHITE)
Defrost thermo. 6
(BLUE) Fuse 7
(BLACK)
Figure A-18
Vinyl tape
60
mm
Figure A-19
21
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
20mm
R10mm R10mm
230mm
Note
• Bending radius of
capillary tube should be
from R5mm to R10mm.
13mm 42mm
20mm
Figure A-20
BROWN
(back side)
Figure A-21
SEC. F-F
F
Figure A-22
22
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
COOLING UNIT
Back condenser
Evaporator
Suction pipe
Sub. condenser
Compressor
Capillary tube
Dryer
23
SJ-D59M/P60M
SJ-D64M/P65M
SJ-D69M/P70M
Dryer
Capillary tube
Charge pipe
Hot pipe
Back condenser
Evaporator
Backcon connector
Charge pipe Connector pipe
Compressor
Suction pipe S.P. connector
Sub. condenser
Compressor butyl
Charge pipe to
Dryer
Hot pipe to
Dryer
Dryer
Dryer support
L-band C
Dryer to
S.P Connector to Charge pipe to Compressor oil cooler to Capillary tube
Compressor's suction tube Compresser Connector pipe
24